INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma



Similar documents
Contents. Document information

LP02 Solar Radiation sensor Compliant with ISO and WMO standards

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Subminiature Load Cell Model 8417

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Modular I/O System Analog and Digital Interface Modules

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Instruction Manual. CVF4 Ventilation Unit

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

GREISINGER electronic GmbH

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

LOGBOX SD. Datalogger. Instruction Manual

Differential Charge Amplifier

Application Note TMA Series

AAV003-10E Current Sensor

Instruction Manual. T3111 T3111L T3111P T3111Ex

Series 6000 Torque measured metal bellow coupling

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Instruction Manual MSC710 MSC710-U MSC710-I

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

Hand-held thermometer Model CTH7000

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

Mounting Instructions. Torque Transducer. A en

Analog signal converters CC-E I/I Current / current isolators

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

ADC-20/ADC-24 Terminal Board. User Guide DO117-5

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

CX Zoner Installation & User Guide

MINI MCR-SL-R-UI(-SP)

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Copyrights 2010 Victron Energy B.V. All Rights Reserved

SCXI CHANNEL ISOTHERMAL TERMINAL BLOCK

Givare NC-SRS 280 och 880

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Digital input modules

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

EGSTON Standard E2xFxWx 12W

Amplified High Speed Fiber Photodetectors

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

HTM2500LF Temperature and Relative Humidity Module

HIH-4000 Series Humidity Sensors

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Pi LVDT and LVDT Amplifier APPLICATION NOTE

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

MOUNTING AND OPERATING INSTRUCTIONS

Loop Calibration and Maintenance

Pressure transmitter For general industrial applications Model A-10

Current Loop Application Note 1495

Duct Humidity Transmitter

Series 510 Submersible Level Transmitters

Building the AMP Amplifier

Reaction Torque Sensor

WEB log. Device connection plans

Application Note 142 August New Linear Regulators Solve Old Problems AN142-1

DS 600. A contact free flux gate based current measurement sensor 600A rms

unit : mm With heat sink (see Pd Ta characteristics)

Technical Note Series

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Charge Regulator SCR 12 Marine

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Calculation of the Current Transformer Accuracy Limit Factor Application Note

SERVICE BULLETIN No.1103

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Precision, Unity-Gain Differential Amplifier AMP03

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Reading: HH Sections , (pgs , )

T0118 T2118 T3118. Instruction Manual

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Manual. Solar Fountain Mobile Phone Charger

ECT[DIN] Repeater in an Aluminum Housing. 2-Wire Isolator, Converter, and. 2-Wire Isolator, Converter, and Repeater in an Aluminum Housing

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Series 7500 Torque Sensor

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Model 201 Wiegand Touchpad Reader Installation Guide

# 2. Selecting and Using Thermistors for Temperature Control

T7560A,B,C Digital Wall Module

Operating Manual UWAPS-TINY Series

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Transcription:

INSTRUCTION MANUAL SIGNAL AMPLIFIER 4-20 ma 0305 260

IMPORTANT USER INFORMATION IMPORTANT USER INFORMATION Reading this entire manual is recommended for full understanding of the use of this product Should you have any comments on the product or this manual we will be pleased to receive them at: Kipp & Zonen B.V. Röntgenweg 1 2624 BD Delft Holland P.O. Box 507 2600 AM Delft Holland Phone +31 (0)15 2698000 Fax +31 (0)15 2620351 E-mail info.kipp@kippzonen.com Kipp & Zonen reserve the right to make changes in the specifications without prior notice. WARRANTY AND LAIBILITY Kipp & Zonen guarantees that the product delivered has been thoroughly tested to ensure that it meets its published specifications. The warranty included in the conditions of delivery is valid only if the product has been installed and used according to the instructions supplied by Kipp & Zonen. Kipp & Zonen shall in no event be liable for incidental or consequential damages, including without limitation, lost profits, loss of income, loss of use and other related exposures, however caused, arising from the faulty and incorrect use of the product. 1

IMPORTANT USER INFORMATION COPYRIGHT 2004 KIPP & ZONEN All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or by any means, without permission in written form from the company. Manual version: 0604 2

IMPORTANT USER INFORMATION Declaration of Conformity According to EC guideline 89/336/EEC 73/23/EEC We Kipp & Zonen B.V. Röntgenweg 1 2624 BD Delft Declare under our sole responsibility that the product Type: CT 24 Name: Solar Sensor Amplifier 4 20 ma To which this declaration relates is in conformity with the following standards: Imissions EN 50082-1 Group standard IEC 1000-4-2 IEC 1000-4-3 IEC 1000-4-4 Emissions EN 50081-1 Group standard EN 55022 Safety standard IEC 1010-1 Following the provisions of the directive B.A.H. Dieterink President KIPP & ZONEN B.V. 3

4 IMPORTANT USER INFORMATION

TABLE OF CONTENTS TABLE OF CONTENTS IMPORTANT USER INFORMATION...1 Declaration of Conformity...3 TABLE OF CONTENTS...5 1. GENERAL INFORMATION...7 2. SPECIFICATIONS...9 3. CONNECTION OF THE CT 24...11 3.1 Minimising interference...13 3.2 Selecting the supply voltage...14 3.3 Connection for current output...15 3.4 Connection for voltage output...17 4. NEGATIVE INPUT SIGNALS...21 5. CALIBRATION PROCEDURE...23 5.1 Standard calibration...23 5.2 Special calibration....25 6. PART NUMBERS...27 5

6 TABLE OF CONTENTS

GENERAL INFORMATION 1. GENERAL INFORMATION With the CT 24 it is possible to convert a low level voltage output from a solar sensor to the standard level of 4 20 ma or (using the installed 500 Ohm resistor) to a 2 10 Volt signal. The CT 24 amplifier is designed to use with Kipp & Zonen solar sensors, to allow long cables between sensor and data logger without external interference. The large operation temperature range from - 30 C to + 70 C and the waterproof housing (IP 65) makes that the CT 24 can be used under the same conditions as all solar sensors. The amplification can be adjusted from the standard 0 20 mv is 4 20 ma to a value that takes the calibration factor of the sensor into account, like 0 1600 W/m² is 4 20 ma. Even negative inputs are allowed through a positive shift of the zero point from +4 to + 8 ma. This allows for negative input signals of about 250 W/m² like a pyrgeometer and net radiometer produces. The CT 24 is protected against reversed polarity, voltage surges on input and output lines and is shielded against EMF disturbance. For pyranometers with temperature sensors there are special connector strips in the CT 24 to connect these sensors from in going to out-going cable. 7

8 GENERAL INFORMATION

SPECIFICATIONS 2. SPECIFICATIONS Current output range nominal 4 to 20 ma Voltage output range @ RL = 500 Ω 2 to 10 V Gain, factory set 1 ma / mv +/- 0.1% Gain adjust +0.5 to +1.0 ma / mv Zero, factory set +4 ma +/- 0.1% Zero adjust +3 to +8 ma Non-linearity < 0.1% Temperature dependence of gain within +/- 0.01% / K Zero drift typical +/- 0.4 µv / K Input impedance 1 MΩ Input range @ gain 0.5, zero 4 ma 0 to +32 mv @ gain 0.5, zero 8 ma -8 to +24 mv @ gain 1, zero 4 ma 0 to +16 mv @ gain 1, zero 8 ma -4 to +12 mv Power supply @ RL 100 Ω min. 12 to 30 VDC Power supply for voltage output 10V min. 20 VDC Temperature range (operating) -30 C to +70 C Housing Aluminium, grey lacquered Dimensions W x D x H 64 x 58 x 34 mm Water proof IP 65 / DIN 40050 Cable glands size 4 to 6,5 mm 9

10 SPECIFICATIONS

CONNECTION OF THE CT24 3. CONNECTION OF THE CT 24 The CT 24 is meant to boost the (low level) output signal of a solar sensor. Therefore the CT 24 amplifier needs to be close to the sensor to maintain a high signal to noise ratio in the cable. The internal layout of the CT 24 is shown in figure 3.1. figure 3.1 Internal layout of the CT 24 To prevent errors due to current loops between input and output it is necessary that the sensor outputs are floating (not connected to ground) or that the ( ) from the power supply is not connected to ground. 11

CONNECTION OF THE CT24 The passive Kipp & Zonen sensors have floating outputs (not connected to sensor housing or shield), so the inputs of the CT 24 will be floating. Actually the rule of thumb is that any connection between CT 24 input LO and output LO is not allowed (e.g. accidentally both grounded). In case of doubt check the impedance of the sensor wires against the sensor housing, this should be infinite. 12

CONNECTION OF THE CT24 3.1 Minimising interference Use sensors with shielded cables. All Kipp & Zonen sensor cables have an internal shield that can be connected to a ground. Many passive Kipp & Zonen sensors have the shield connected to the sensor housing. If the sensor is mounted to a grounded frame, the shield of the input cable is grounded too. If the grounding at the sensor is not sure, but shielding is necessary, the shield can be grounded via the output cable or at the CT 24. For this purpose pin 1 of the input connector strips can be used or one of the screws that holds the PC board in place. The output cable can be unshielded or shielded. SHIELD 1 1 SHIELD SIGNAL INPUT 2 2 SIGNAL OUTPUT SIGNAL + INPUT 3 3 SIGNAL + OUTPUT INTERCONNECTION 4 4 INTERCONNECTION INTERCONNECTION 5 5 INTERCONNECTION INTERCONNECTION 6 6 INTERCONNECTION INTERCONNECTION 7 7 INTERCONNECTION INTERCONNECTION 8 8 INTERCONNECTION INTERCONNECTION 9 9 INTERCONNECTION figure 3.2 internal connection strip 13

CONNECTION OF THE CT24 3.2 Selecting the supply voltage The CT 24 operates as a so-called 2 wire current transmitter. This means that the amplifier receives its operating current from the loop that represents the current output signal. The loop has to be powered with a power supply or active receiver capable of providing a voltage between 12 and 30 Volt @ 100 Ohm loop resistance. When later on the current is to be transformed to a voltage, it is important to select the power supply voltage in accordance with the desired output voltage. Example: Required voltage over the CT 24 is 10 Volt (minimum value) Required voltage over the 500 Ohm resistor is 10 Volt (@ 20mA) This implies that the supplied voltage has to be at least 10+10 = 20 Volt. Be aware that an active sensor (with some electronics) can generally not be powered together with its CT 24 by the same power supply. In that case the sensor output is normally connected with the common of the power supply and consequently also with the CT 24 output LO. This is against the rule of thumb. 14

CONNECTION OF THE CT24 3.3 Connection for current output When the CT 24 is used as a standard 4 20 ma amplifier (transmitter) only 2 input and 2 output wires have to be connected plus two times the shielding of both cables. This configuration is least sensitive to shielding and grounding problems, because the voltage variations in the cable leads are relative small. Grounding and coupling of the shields from input cable and output cable is often no problem and the power supply and data logger common may be grounded as well, preferably all at the same ground. The cable coming from the sensor is lead through the cable gland and directly connected to pin 2 (-) and 3 (+) of the input connector strip. Check your sensor manual for the colour of the wires. The outgoing cable has the same number of wires as the input cable and can be connected to the output strip. Make sure both cables have their shield connected to ground. Input connector pins number 4 till 9 are interconnected with the output connector pins and can be used to transfer the signal from temperature sensors like a Pt100 or thermistor to the output cable. (First remove the 500 Ω resistor from the terminal strip). 15

CONNECTION OF THE CT24 Shield Power supply + Current out figure 5.3 connection for current output 16

CONNECTION OF THE CT24 3.4 Connection for voltage output When a voltage signal is needed directly from the CT 24, the conversion from current to voltage can be made inside the CT 24. For this purpose a precision 500 Ohm resistor is supplied that can be connected through the connection strip. This requires however four wires. The wires used to supply the current and the wires that carry the voltage output can not be combined. Even though the return from the current loop and the low of the voltage output are connected to the same level, the voltage drop over the cable makes it necessary to use separate wires for the voltage output. Shield Power supply + Signal + Signal Power supply figure 3.4 voltage output connection 17

CONNECTION OF THE CT24 So when the CT 24 is used with a voltage output, 2 input and 4 output wires have to be connected plus two times the shielding of both cables. Of course any other R L can be used to transform the output current to a voltage, as long as the guideline from chapter 5 is followed. (E.g. RL= 50 Ω to make an output voltage range of 0.2 to 1 V ). If the resistor is placed at the end of the current loop (near the power supply), only two wires are necessary. The power supply but also the loop indicator or passive receiver should be floating from ground to give highest freedom of connection or configuration. With a voltage output connection it is most advantageous to use a power supply and read out equipment both floating from ground. Only in that case the shield of the input cable or the sensor housing (and not more) can be grounded at the sensor side. Connect only input cable shield and output cable shield together, if you have to ground at the data logger side. The CT 24 will oscillate probably, but connecting the signal+ of the data logger to the same ground will stop this. This is of course only possible with floating data logger and floating power supply of course. (At principle a shielded output cable is no must and the input cable shield can also be carried on to the data logger by a single wire). 18

CONNECTION OF THE CT24 At this place we have to precise the rule of thumb. The oscillating occur due to a certain capacitive coupling (> 500 pf) between CT 24 input LO and common of power supply and data logger, especially in the voltage output mode with the internal RL= 500 Ω active. The capacitive loop consists of a capacitance from input leads to (grounded) input cable shield. This capacitance is in series with the capacitances from power supply- and data logger- and the corresponding lead in the cable to respectively ground and output cable shield. The effect of the coupling can be minimized by using a very short input cable, an unshielded output cable and/or making the output voltage swing as low as possible, preferable by using the current output configuration or by reducing the voltage swing to 0.2 to 1 V with an RL = 50 Ω. Consequently if power supply and/or data logger are connected to a ground, grounding the shield of the input cable directly or via the sensor housing introduces oscillation of the CT 24. Generally speaking no second ground reference is tolerated in a configuration with power supply or data logger connected to ground. Consequently no shielding against external E.M. fields is possible and also the sensor housing must be floating. The application field of this configuration is therefore restricted and should be tested at location firstly. 19

20 CONNECTION OF THE CT24

NEGATIVE INPUT SIGNALS 4. NEGATIVE INPUT SIGNALS When using a pyrgeometer or net radiometer as input, the signal can be both positive and negative. To allow for negative inputs the zero point from the CT 24 can be adjusted to + 8mA. (See fig 3.1 zero adjust) Example with a pyrgeometer CG 1: Sensor output 250 to + 250 W/m 2 = -3.750 mv to + 3.750 mv Gain is set to 1 ma / mv Output range is 3.75 x 2 = 7.5 ma To see both negative and positive signals on the output the zero has to be shifted +4 ma (3.75 V minimal) to +8 ma. See the next chapter for the calibration procedure. Pyranometer signals can go slightly negative during clear nights. This information is not lost, if a normal zero-point of 4 ma is applied. The loop current can decrease down linearly down to 3 ma. 21

22 NEGATIVE INPUT SIGNALS

CALIBRATIION PROCEDURE 5. CALIBRATION PROCEDURE Calibration can be performed in two ways, either the CT 24 is calibrated standard with an amplification of 1mA per 1 mv and no offset adjusted (see chapter 5.1) Or a special calibration is made where the amplification and / or offset are adapted to the sensor (see chapter 5.2). Necessary equipment for calibration: accurate voltage source power supply ( +12 to +30 Volt) accurate multimeter ( current and voltage) small screwdriver to adjust the potentiometers Resistor (R S ) equal to the sensor element impedance Caution: Read the warning at chapter 3.4 carefully. 5.1 Standard calibration To perform a standard calibration, connect R S in the CT 24 to the input terminal strip pin 2 and 3. The power supply has to be connected to the output pins 2 and 3. Measure the loop current with the multimeter on ma range. In this situation a zero input is simulated and the zero output can be adjusted to +4 ma with the zero adjust potentiometer. 23

CALIBRATIION PROCEDURE Then a +16 mv signal has to be applied to the input. With the gain potentiometer the output is adjusted to +20 ma. This gives a maximum full-scale input of +16 mv. Finally connect the sensor with its shielding etc. and check whether the dark signal (sensor darkened) is again close to 4 ma. If not, the CT 24 can oscillate etc., and the output signal is unreliable. Check whether the rules of thumb of chapter 3.4 are fulfilled. 24

CALIBRATIION PROCEDURE 5.2 Special calibration. With special calibration is meant that the sensitivity of the sensor (pyranometer) is used to adjust the gain. This is to obtain for instance a conversion of 200 W/m 2 per ma. Example: CM 11 with a sensitivity of 5.14 x 10-6 V / W/m 2 and max. irradiance of 2000 W/m 2 The zero point is set as described above under standard calibration. For 200 W/m 2 / ma the applied voltage to the input to set the gain, is calculated in the following way: 5.14 x 10-6 x 2000 = 10,28 mv, and adjust the output to +4 ma + (2000/200) = 14 ma This should always be smaller than 20 ma. An input signal change of 0 to 2000 W/m 2 gives an output change of 4 to 14 ma. With the 500 Ohm resistor this results in a voltage change of 2 to 7 Volt. Depending on the sensor output it can be better to use a conversion of 50 or 100 W/m 2 per ma. Of course using the total +16 ma range gives the optimal resolution on the output. 25

26 CALIBRATIION PROCEDURE

PART NUMBERS 6. PART NUMBERS CT 24 0305 710 Resistor 500Ω 2686 002 Instruction manual 0305 260 27

28 PART NUMBERS

Our customer support remains at your disposal for any maintenance or repair, calibration, supplies and spares. The address is as follows: Customer Support Für Servicearbeiten und Kalibrierung, Verbrauchsmaterial und Ersatzteile steht Ihnen unsere Customer Support Abteilung unter folgender Adresse zur Verfügung: Notre service 'Support Clientèle' reste à votre entière disposition pour tout problème de maintenance, réparation ou d'étalonnage ainsi que pour les accessoires et pièces de rechange. Leur adresse est la suivante : Holland Kipp & Zonen B.V. Röntgenweg 1 2624 BD DELFT T +31 15 269 8000 F +31 15 262 0351 E kipp.holland@kippzonen.com USA Kipp & Zonen USA Inc. 125, Wilbur Place BOHEMIA/NY 11716 T +1 631 589 2065 F +1 631 589 2068 E kipp.usa@kippzonen.com UK Kipp & Zonen Ltd. P.O. Box 819, LINCOLN, Lincolnshire LN6 0WY T +44 1522 695 403 F +44 1522 696 598 E kipp.uk@kippzonen.com Germany Gengenbach Messtechnik Heinrich-Otto-Strasse 3 D-73262 REICHENBACH/FILS T +49 7153 9258 0 F +49 7153 9258 160 E info@rg-messtechnik.de France Kipp & Zonen S.A.R.L. 7, avenue Clément Ader ZA Ponroy - Bât. M F-94420 LE PLESSIS TREVISE T +33 1 49 62 4104 F +33 1 49 62 4102 E kipp.france@kippzonen.com Kipp Zonen & www.kippzonen.com