2 PLZ RANGE 14-18-20
3 TECHNICAL NUMBERS
4 MAIN COMPONENTS CONTROL SAFETY HYDRONIC OUTLET WATER TEMPERATURE INLET WATER TEMPERATURE AIR OR WATER EXTERNAL TEMPERATURE FRESH AIR WITH PRESSURE DIFFERENTIAL WATER SAFETY THERMOSTAT (96+0-6) PELLET SAFETY THERMOSTAT (88+0-6) VACUUM SWITCH MICROSWITCH FIREBOX DOOR (evaluation) MICROSWITCH PELLET LID (evaluation) VARIABLE CIRCULATOR (ON REQUEST CLASS A PWM DRIVED) AIR PURGE EXPANSION TANK (6l) SAFETY WATER PRESSURE VALVE(2,5 bar)
5 LAYOUT MANOMETER CONTROL PANEL SAFETY THERMOSTAT WATER/PELLET AESTHETIC FINISHING FRESH AIR INTAKE IGNITER FEEDING MOTOR
6 LAYOUT AIR PURGE BOILER (60L) FUNCTIONAL FIREBOX DOOR SERVICE WINDOW OPENING KNOBS
7 LAYOUT PELLET LID FUEL HOPPER FEEDING SYSTEM FRESH AIR INTAKE FIREBOX DOOR
8 LAYOUT WATER POCKET WATER OUTLET INSULATED DOOR CLEANING SPRING WATER INLET BURN POT ASH PAN CLEANING SYSTEM
9 LAYOUT EXHAUST OUTLET WAYS CLEANING AREAS WATER POCKET WATER EXCHANGER PIPES WATER JACKET
10 LAYOUT SPIDER CLEANING SYSTEM WITH SPRINGS EXPANSION CHAMBER/PLENUM EXHAUST OUTLET
11 ELECTRONIC
12 CONTROL BOARD ON LIGHTING STAND BY OFF
OPERATION BETWEEN MENU Left/Right arrows ->move between menus +/- buttons ->move between lower menus enter button -> confirm operation +/- buttons ->modify values cancel button -> go back to previous menu Power button perform ON/OFF or reset alarms
SETUP LOWER LEVELS [ 1 ] KEYBOARD LOCK : OFF / lo / hi [ 2 ] DISPLAY BRIGHTNESS : Min 1 / Max 5 [ 3 ] ROLLING MENU : OFF (Last value set) / 1 (temperature, range, clock) / 2 (temperature) / 3 (clock) / 4 (range) [ 4 ] BUZZER VOLUME = OFF / (Min) 1 / (Max) 5 [ 5 ] SOFTWARE VERSION [ 6 ] HOURS TO SERVICE [ 7 ] INSTALLER MENU [ 8 ] SERVICE MENU
15 HEATING SYSTEM CONFIGURATION [ 7 ] r - - 0 r - - 5 4 0 1 1 4
16 CONFIGURATION 1 2 SET Outlet temperature (T01) Power (P)
17 CONFIGURATION 1
18 CONFIGURATION 2 3 SET Room Temperature (T05) Outlet Temperature (T01) Relighting Delta Room Temperature Antifreeze Temperature Power (P)
19 CONFIGURATION 2!
20 CONFIGURATION 3 SET Heat Storage Temperature (T05) Relighting Delta Heat storage Temperature Antifreeze Temperature Power (P) 3
21 CONFIGURATION 4 SET Heat Storage Temperature (T05) Relighting Delta Heat storage Temperature Antifreeze Temperature Power (P) 3
22 CIRCULATOR WORKS (configuration 1 and 2)
23 CIRCULATOR WORK (configuration 3 and 4)
24 WORK DEFINITION
25 POWER LEVEL SET [ 1 ] 1 min=1 MAX=5
26 TEMPERATURE SET [ 1 ] 2 0 1 4 T05 T01 T02 DESCRIPTION CONFIGURATION 1 2 3 4 Room T (T05) [1] Heat storage T (T05) [1] [1] Outlet T (T01) [1] [2] Antifreeze T [3] [2] [2] Relighting [4] [3] [3]
27 TEMPERATURE SETS T05 T01 T02 DESCRIPTION Room T (T05) [1] CONFIGURATION 1 2 3 4 Heat storage T (T05) [1] [1] Outlet T (T01) [1] [2] Antifreeze T [3] [2] [2] Relighting [4] [3] [3] Room temperature (configuration 2 only): setting this value defines the desired room temperature, read directly by a probe fitted on the stove. Storage temperature (configurations 3 and 4 only): identifies the minimum desired temperature inside the storage tank. Water temperature (configurations 1 and 2 only): setting this value changes the desired hot water outlet temperature. Frost protection temperature (configurations 2, 3 and 4): defines the minimum temperature below which the stove switches on (outside of preset time bands). Restart delta (configurations 2, 3 and 4): this is the number of degrees centigrade below the switch-off temperature at which the stove switches on again automatically. For example, if the stove is set to switch off at 20 C and Restart delta is set to 4 C, the stove will switch on again when the temperature measured is less than or equal to 16 C.
28 FUNCTIONS AVAILABLE ECO MODE SAVING FUNCTION Enabling this function means that the stove switches off when reaching the desired room temperature. If this function is not enabled, the stove modulates operation so as to maintain the desired temperature while consuming the least amount of fuel possible. The "Eco Mode" function is only available in configuration 2. FROST PROTECTION FUNCTION In configurations 2, 3 and 4 a minimum temperature can be set below which the stove will switch on (outside of the set time bands).
29 TIMER MENU
30 TIME RANGE [ 3 ] [ 1 2 [ P 3 0] 1] P Ton Toff 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 7.00 9.00 2 9.00 12.00 3 4 5 11.00 14.00 15.00 21.00 17.00 21.00 6 9.00 18.00
31 SET UP PROGRAM [ 4 ] [ P d 1] 2] d 21 Programms TIME SLOTS 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 P1 P3 P5 2 P1 P3 P5 3 P1 Off P4 4 P1 P3 P5 5 P1 P3 P5 6 P1 P2 P4 7 P6 Off Off
32 SERVICE MENU [ 8 ] r - - 0 r 2-8 - 504 2 9 2+8+5+4+ KW
33 SERVICE MENU FACTORY DEFAULT VALUES DIGITAL INPUT ANALOG INPUT DIGITAL OUTPUT COUNTER ALARM MEMORIES
34 FUNZIONE LIMITI PAR00 durata massima Fuel Ignition 15 8-20 (±1) PAR01 Timeout fase di FireCheck 3 2-6 (±1) FEEDER-1 PAR03 durata OFF coclea HeatUp 30 0-200 (±1) PAR04 durata lavoro coclea HeatUp 110 90-130 (±1) PAR05 durata OFF coclea Fuel Ignition 110 0-200 (±1) PAR06 durata lavoro coclea Fuel Ignition 20 10-30 (±1) PAR07 durata OFF coclea FireCheck 80 0-200 (±1) PAR08 durata lavoro coclea FireCheck 20 10-30 (±1) PAR10 durata lavoro coclea potenza 1 10 6-12 (±1) PAR18 durata lavoro coclea potenza 5 21 19-23 (±1) FAN-1 PAR19 portata ventilatore fumi in StopFire 240 200-255 (±1) PAR20 portata ventilatore fumi in TestFire 160 130-200 (±1) PAR21 portata ventilatore fumi in HeatUp 130 100-160 (±1) PAR22 portata ventilatore fumi in Fuel Ignition 200 180-255 (±1) PAR23 portata ventilatore fumi in FireCheck 200 180-255 (±1) PAR24 portata ventilatore fumi in potenza 1 70 50-100 (±1) PAR28 portata ventilatore fumi in potenza 5 150 130-255 (±1) WATER PAR50 deltat per uscita dal CoolFluid 20 1 20 (±1 ) PAR52 temp MAX modulazione acqua 80 45 80 (±1 ) PAR53 deltat per ingresso in CoolFluid (solo in CONF1/3/4) +10 0 10 (±1 ) GASSES PAR54 temp fumi per uscita da FireCheck 50 40-80 (±1 ) PAR55 MAX temp fumi per modulazione 150 150-190 (±1 ) PAR56 temp fumi per uscita da StopFire 40 35-60 (±1 ) PAR57 temp fumi MAX 200 200-255 (±1 ) PAR59 MIN temp fumi durante lavoro 45 40-60 (±1 ) CLEANING PAR60 tempo tra due cicli di pulizia 40 0-60 (±1 ) PAR61 tempo ciclo pulizia 40 0-120 (±1 ) PAR62 portata ventilatore fumi in pulizia 255 100-255 (±1) WATER PUMP PAR67 T media mand/rit per passaggio da anti-condensa a lavoro pompa 50 30-70 (±1 ) PAR68 T media mand/rit per start pompa 40 30-70 (±1 ) PAR69 deltat mand/rit MAX per modulazione pompa 7 0-1 5 (±1 ) TIMING PAR70 durata fase di HeatUp 45 20-120 (±1 ) PAR71 durata calcolo gradiente 6 0-255 (±1 ) PAR72 deltat calcolo gradiente 2 0-255 (±1 ) OPERATING MODE PAR76 Configurazione di default 1 0 4 (±1) PRESS/FLOW PAR82 press MIN in accensione 10 0-100 (±1) PAR83 delay prima di verificare PAR82 30 0-120 (±1 ) HEAT ACC. PAR85 deltat mand/rit MIN per start pompa 1 0-30 (±1 ) PAR86 deltat mand/puffer MAX per modulazione pompa 7 0-30 (±1 ) MATERIAL TYPE PAR92 tipo pellet di default 2 1-3 (±1) SERVICE HOURS PAR94 giorni per avviso di manutenzione 84 84-255 (±1) ADVANCED WATER SERVICE MENU
35 WORKING LOGICS
36 WORKING LOGICS Fire Up 1. Test Fire: verify presence of embers. In that case exclude the igniter 2. Heat Up: Igniter, exhaust fan and feeding system switch on 3. Ignition: Waiting flame 4. Ignition Test: Check temperature in order to know if flame is present
37 WORKING LOGICS Burning 1. Power levels: Power 1 5 2. Regulation Air: Room Fan speed (air version) 1 5, Auto, Hi 3. Regulation Gas: Safety exhaust temperature modulation 4. Regulation Fluid: Outlet temperature modulation 5. Burn Pot : Cleaning Cycle
38 WORKING LOGICS Fire down 1. Stop Fire: exhaust fan at full speed to clean burn pot and cool down the stove. 2. Cool fluid: stove is in stand-by status. Switch off condition (EcoMode) because target air/water is reached. On temperature demand stove will lighting automatically.
39 WORKING LOGICS OFF 1. OFF: burn pot is cold. Stove is waiting an external event (button, timer or thermostat)
40 WORKING LOGICS Pressure = AIR FLOW Fresh air intake P- P+ exhaust FAN RPM current AIR FLOW BEFORE: From RPM we got AIR FLOW NOW: From AIR FLOW we get RPM time