Magnetic Resonance Imaging



Similar documents
Syed Ammal Engineering College, Ramanathapuram, Tamil Nadu , India

FDA Guidelines for Magnetic Resonance Equipment Safety

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

SITE IMAGING MANUAL ACRIN 6698

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

Subject: Magnetic Resonance Imaging (MRI) Information on Sorin Group Heart Valve Prostheses and Annuloplasty Devices

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

5 Factors Affecting the Signal-to-Noise Ratio

REVEAL LINQ LNQ11. Insertable Cardiac Monitor MRI procedural information. MRI Technical Manual

Prepublication Requirements

Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants

Magnetic Resonance Safety Testing of a Newly- Developed Fiber-Optic Cardiac Pacing Lead

Musculoskeletal MRI Technical Considerations

Basic Principles of Magnetic Resonance

GE 3.0T NPW,TRF,FAST,F R NPW,TRF,FAST,F R

RFID BASED VEHICLE TRACKING SYSTEM

Replacement Heart Valve Product Description (Stented Tissue) Models Reference

Selected Radio Frequency Exposure Limits

LifeStent XL Biliary Stent System

Technique and Safety of. by Pierluigi Castellone, Electronics Engineer Brain Products General Manager

Invited. Pre-MRI Procedure Screening: Recommendations and Safety Considerations for Biomedical Implants and Devices

Numerical Modelling of E-M Occupational Exposures associated with MRI

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)

Human Exposure Limits

A Primer on Medical Device Interactions with Magnetic Resonance Imaging Systems

MRI Issues for Implants and Devices

Wireless Radio Frequency Coil for Magnetic Resonance Image of Knee Joint

MGH Adult Diffusion Data Scanning Protocols

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

MRI SAFETY JEOPARDY (Technologist Edition) Questions

Breast MRI Quality Control

Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone

6900PTFX bioprosthesis Carpentier-Edwards PERIMOUNT Magna mitral pericardial

Thermal Effects of Mobile Phones

Configuration and Use of the MR Knee Dot Engine

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

Specific Absorption Rate (SAR) in the head of Tablet user's

MUCH work has been reported on determining the specific

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

GE Medical Systems Training in Partnership. Module 12: Spin Echo

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

32-Channel Head Coil Imaging at 3T

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

12 pericardial bioprostheses. 7300TFX Carpentier-Edwards bioprosthetic valved conduit

Magnetic Resonance Imaging

RICHARD T ELL ASSOCIATES,INC.

AN2866 Application note

Data. microcat +SPECT

Power Injectors for Diagnostic Imaging

LONI De-Identification Policy

4. It is possible to excite, or flip the nuclear magnetic vector from the α-state to the β-state by bridging the energy gap between the two. This is a

Instructions for Use. Device Description The AMPLATZER Vascular Plug II is a self-expandable nitinol mesh occlusion device (see Figure 1).

MEASUREMENT SET-UP FOR TRAPS

EH-20 20m antenna. By VE3RGW

MRI Department Goals. Effective Ways to Improve Patient Cooperation and Safety in MRI Exam. Lecture Topics

Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions

Human Exposure to Outdoor PLC System

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz

Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi

Evolving Bar Codes. Y398 Internship. William Holmes

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact:

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

Advanced Measurements of Microwave Oven Leakage

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

University Children s Hospital Basel

Magnetic Resonance Imaging Environment Safety in Ontario

DUPONT PERFORMANCE POLYMERS Joint Design: A Critical Factor in Strong Bonds GENERAL GUIDELINES FOR ULTRASONIC, VIBRATION AND SPIN WELDING

MRI SEQUENCES. 1 Gradient Echo Sequence

2012 Operating Room Design Manual

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications

MRI for Paediatric Surgeons

AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS

Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners

MR Information Date: March 11, 2014

Allium Ureteral Stent (URS)

September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D Kamp-Lintfort

Body SAR and EU. B. Derat

INTRODUCTION. A. Purpose

RECOMMENDATION ITU-R F (Question ITU-R 157/9) b) that systems using this mode of propagation are already in service for burst data transmission,

Kap 8 Image quality, signal, contrast and noise

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

GUIDE TO SETTING UP AN MRI RESEARCH PROJECT

Functional neuroimaging. Imaging brain function in real time (not just the structure of the brain).

Phantom Test Guidance

Ultrasonic Wave Propagation Review

Enhanced Stripline Scanning Array B.M. Cahill and J.C. Batchelor

Waveguide Access Point WGA631. Product Guide

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements

Transcription:

Magnetic Resonance Imaging 31 (2013) 1439 1444 Contents lists available at ScienceDirect Magnetic Resonance Imaging journal homepage: www.mrijournal.com Technical notes Evaluation of MRI issues for an access port with a Radiofrequency Identification (RFID) tag, Blake Titterington a, Frank G. Shellock b, a Biochemistry Department, Frank R. Seaver College of Science and Engineering, Loyola Marymount University, Los Angeles, CA 90045, USA b Keck School of Medicine, University of Southern California and Institute for Magnetic Resonance Safety, Education, and Research, Los Angeles, CA 90045, USA article info abstract Article history: Received 17 February 2013 Revised 7 April 2013 Accepted 8 April 2013 Keywords: MRI safety MRI implants Specific absorption rate Artifacts Access port RFID Objective: A medical implant that contains metal, such as an RFID tag, must undergo proper MRI testing to ensure patient safety and to determine that the function of the RFID tag is not compromised by exposure to MRI conditions. Therefore, the objective of this investigation was to assess MRI issues for a new access port that incorporates an RFID tag. Materials and Methods: Samples of the access port with an RFID tag (Medcomp Power Injectable Port with CertainID; Medcomp, Harleysville, PA) were evaluated using standard protocols to assess magnetic field interactions (translational attraction and torque; 3-T), MRI-related heating (3-T), artifacts (3-T), and functional changes associated with different MRI conditions (nine samples, exposed to different MRI conditions at 1.5-T and 3-T). Results: Magnetic field interactions were not substantial and will pose no hazards to patients. MRI-related heating was minimal (highest temperature change, 1.7 C; background temperature rise, 1.6 C). Artifacts were moderate in size in relation to the device. Exposures to MRI conditions at 1.5-T and 3-T did not alter or damage the functional aspects of the RFID tag. Conclusions: Based on the findings of the test, this new access port with an RFID tag is acceptable (or, MR conditional, using current MRI labeling terminology) for patients undergoing MRI examinations at 1.5-T/ 64-MHz and 3-T/128-MHz. 2013 Elsevier Inc. All rights reserved. 1. Introduction An access port is an implant that is utilized to provide long-term vascular administration of chemotherapeutic agents, antibiotics, analgesics, or other medications. This device is typically implanted in a subcutaneous pocket, in the subclavicular area with a catheter inserted in the jugular, subclavian, or cephalic vein. Specially designed access ports may also be used for power-injection of contrast media to facilitate a diagnostic radiologic procedure, such as using IV contrast agents for a CT or magnetic resonance imaging (MRI) examination. Funding: Unrestricted research grant provided by Medcomp, Harleysville, PA. Author contributions: BT, FGS, together, made substantial contributions to the conception and design of this study, the acquisition of the data, the analysis and interpretation of data, the drafting of the manuscript and revising the manuscript for important intellectual content. BT, FGS provided final approval of the version to be published. Corresponding author. Institute for Magnetic Resonance Safety, Education, and Research, Los Angeles, CA 90045, USA. Tel.: +1 310 670 7095; fax: +1 310 417 8639. E-mail addresses: batitterington@gmail.com (B. Titterington), frank.shellock@mrisafety.com (F.G. Shellock). At the present time, access ports require the use of ionizing radiation (fluoroscopy, CT, or x-ray) to properly identify a radiopaque marker or other visible lettering (e.g., the marking of CT on the implant is often used) that indicates that the port is acceptable for a power injection (e.g., up to 5-cc/sec at 300 psi). Failure to use an access port specifically developed for power injections can result in serious patient injuries. Therefore, it is vital to confirm that the access port is, in fact, indicated for power injection and, thus, able to withstand high-pressure conditions. Recently, a new access port was developed that incorporates a radiofrequency identification (RFID) device or tag. An RFID tag is a microchip attached to an antenna that allows a wireless, non-contact mechanism utilizing radio-frequency electromagnetic fields to transfer electronically-stored data from the tag (which is attached to or embedded in an object, such as an implant), to a scanner or reader, providing automatic identification of that item [1]. Importantly, an access port that incorporates RFID technology permits the use of a reader to positively identify the port as a power injection device, eliminating the requirement to strictly use ionizing radiation to determine the type of port that is implanted in the patient. 0730-725X/$ see front matter 2013 Elsevier Inc. All rights reserved. http://dx.doi.org/10.1016/j.mri.2013.04.005

1440 B. Titterington, F.G. Shellock / Magnetic Resonance Imaging 31 (2013) 1439 1444 A medical implant, such as an access port with an RFID tag, must undergo proper MRI testing that involves characterization of magnetic field interactions, MRI-related heating, and artifacts to ensure patient safety [1 6]. Notably, because the electromagnetic fields associated with MRI may compromise the reliability of the data or damage the functional aspects of the RFID tag used with the access port [2], it is important to specifically evaluate this component of the new implant. Therefore, the objective of this investigation was to assess these afore-mentioned MRI issues for a new access port that incorporates an RFID tag. 2. Materials and methods 2.1. Access port with an RFID tag Samples of a new access port that incorporates a radiofrequency identification (RFID) device or tag (Medcomp Power Injectable Port with CertainID; Medcomp, Harleysville, PA) underwent evaluation in this investigation (Fig. 1). The materials used for this port include titanium (including a small connector component, length, 7-mm), polysulfone, silicone, tungsten, and ferrite. The RFID tag, when activated, transmits a bit stream encoding a 16-character code and may be read by means of an activation field that is provided by a handheld scanner or reader (Veracity Reader, Medcomp, Harleysville, PA), which supplies the power for its operation (Note: the reader was not evaluated for MRI issues and, therefore, it is not permitted to be in the MR system room.) The handheld reader displays information viewable by the medical practitioner, conveying that the implanted port is an RFID Port. The frequencies used by the RFID tag include the following ranges: 129.0 to 133.2 khz and 135.2 to 139.4 khz. 3. Evaluation of magnetic field interactions The access port with an RFID tag was assessed for magnetic field interactions (i.e., translational attraction and torque) at 3-T (Excite, Software G3.0-052B, General Electric Healthcare, Milwaukee, WI) using standard testing techniques [2 7]. A static magnetic field strength of 3-T was selected for this investigation because it is the highest magnetic field currently in widespread use [8]. Therefore, the results for magnetic field interactions will apply to MR systems operating at 3-T or less [8]. 3.1. Translational attraction Translational attraction was determined using the deflection angle test [2 7]. A test fixture (protractor with 1 -graduated markings attached to a holding device) was used to measure the deflection angle for the access port with an RFID tag in the 3-T MR system. This device was attached to the protractor at the 0 indicator using a 20-cm-long string (less than 1% of the implant s weight) [2 7]. The deflection angle apparatus was placed at the highest patient accessible spatial gradient magnetic field for the 3-T MR scanner, which is 720 G/cm and occurs at an off-axis position, 74-cm from isocenter of the MR system [2 7,9]. Gauss line plots, gauss meter readings (Extech 480823 Electromagnetic Field and Extremely Low Frequency Meter; Extech, Nashua, NH, USA), and visual investigation were used to determine the point of the highest, patient accessible, spatial gradient magnetic field [2 7,9]. The access port with an RFID tag was held vertically from the test fixture and then released. The deflection angle to the nearest 1 was measured three times and a mean value was calculated. 3.2. Evaluation of torque The access port with an RFID tag was next evaluated for magnetic field-induced torque at 3-T using a previously described technique [2 7]. The test fixture (a flat plastic material, 15-cm 15-cm, with a millimeter grid) with the test sample was placed at the center of the 3-T MR system, where the effect of torque imposed on a metallic object is known to be the greatest [2 7]. The implant was then moved 45 relative to its previous position and observed for alignment or rotation. This procedure was repeated to encompass 360 of rotation, three times, for the access port with an RFID tag, with this implant placed along its short and long axes [2 7]. A previouslydescribed, qualitative scale was used to characterize the results, as follows [2 7]: 0, no torque; +1, mild or low torque, the implant slightly changed orientation but did not align to the magnetic field; +2, moderate torque, the implant aligned gradually to the magnetic field; +3, strong torque, the implant showed rapid and forceful alignment to the magnetic field; +4, very strong torque, the implant showed very rapid and very forceful alignment to the magnetic field. 4. Evaluation of MRI-related heating 4.1. Phantom and experimental set-up Fig. 1. The access port with an RFID tag that underwent testing for MRI issues. The access port with an RFID tag was assessed for MRI-related heating at 3-T/128-MHz using a standardized test methodology [2,4 7,10]. For this test, a plastic American Society of Testing and Materials (ASTM) International phantom (dimensions of the head/ torso phantom: head portion width, 16-cm; length, 29-cm; depth, 18-cm; torso portion width, 60-cm; length, 43-cm; depth, 18-cm) was filled to a depth of 10-cm with gelled-saline (i.e., 1.32-g/L NaCl plus 10 g/l polyacrylic acid in distilled water) and the implant was placed in a position that would result in potentially substantial MRI-related heating (i.e., where there is a high uniform electric field tangential to the implant, ensuring extreme radiofrequency heating conditions for this experimental setup, based on an analysis of the ASTM International phantom and the MRI conditions used for this assessment). A relatively high level of RF energy was applied during the MRI-related heating experiment, as previously described [2,4 7].

B. Titterington, F.G. Shellock / Magnetic Resonance Imaging 31 (2013) 1439 1444 1441 4.2. Temperature recording and placement of thermometry probes A fluoroptic thermometry system (Model 3100, LumaSense Technologies, Santa Clara, CA) was used to record temperatures measurements for the access port with an RFID tag. Three thermometry probes (Model SFF-2, LumaSense Technologies, Santa Clara, CA) were placed, as follows: Probe #1; sensor portion of the probe placed at one end of the implant, in contact with the connector; Probe #2; sensor portion of the probe placed at the other end of the implant; Probe #3; sensor portion of the probe placed in the middle of the implant. In addition, a reference probe was positioned in the phantom approximately 35-cm across from the implant [2 4,10]. 4.3. MRI conditions MRI was conducted during the heating test at 3-T/128-MHz (Excite, Software HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI) using a transmit body radiofrequency (RF) coil. MRI parameters were applied to generate a relatively high level of RF energy, producing an MR system-reported, whole body averaged specific absorption rate (SAR) value of 2.9-W/kg (fast spin echo pulse sequence; axial plane; TR, 425-ms; TE, 14-ms; echo train length 4; Bandwidth 16-kHz; matrix size, 256 256; field of view 40-cm; section thickness, 10-mm; number of slices, 40) [4 7]. The landmark position (i.e., the center position or anatomic region for the MRI) and section locations were selected to encompass the entire area of the access port with an RFID tag. 4.4. Protocol The gelled-saline-filled phantom was placed in the 3-T MR system room and allowed to equilibrate to the surrounding temperature for more than 24 h. The access port with an RFID tag was positioned in the phantom and the fluoroptic thermometry probes were applied. Baseline temperatures were recorded at 5-s intervals for 5 min, and MRI was then conducted for 15- min, recording temperatures at 5-s intervals [2 7]. Post-MRI temperatures were recorded for 2-min at 5-s intervals. Proper fluoroptic thermometry probe positioning relative to the implant was confirmed immediately before and after the evaluation for MRI-related heating. The highest temperature changes are reported, herein. Background temperatures (i.e., without the implant present in the phantom) were also recorded in the gelled-saline-filled ASTM International phantom [4 7,10]. Accordingly, the temperature changes were recorded at the same fluoroptic thermometry probe positions and at the same time intervals as those used when measuring the temperatures for the access port with an RFID tag as part of a proper MRI-related heating assessment [4 7,10]. The highest temperature change obtained from this evaluation is also reported. 5. Evaluation of artifacts MRI artifacts were evaluated for the access port with an RFID tag at 3-T/128-MHz with this implant attached to a plastic plate and positioned in a gadolinium-doped, saline filled phantom, as previously described [2 7]. The following pulse sequences were used [2 7]: (1) T1-weighted, spin echo pulse sequence; repetition time, 500 ms; echo time, 20 ms; matrix size, 256 256; section thickness, 10-mm; field of view, 24-cm; number of excitations, 2; bandwidth; 16 khz; (2) Gradient echo (GRE) pulse sequence; repetition time, 100 ms; echo time, 15 ms; flip angle, 30 ; matrix size, 256 256; section thickness, 10-mm; field of view, 24-cm; number of excitations, 2; bandwidth, 16 khz. Section locations were selected through the access port with an RFID tag to encompass the long axis (i.e., oriented along the small metal connector) and short axis of this implant to show the largest artifact sizes (i.e., prescribed from multiple localizer scans). The frequency encoding directions were parallel to the imaging planes. Planimetry software included with the MR system (accuracy and resolution ±10%) was utilized to determine the cross-sectional areas of the largest artifact for each pulse sequence and imaging plane [2 7]. Display parameters (i.e., window and level settings, magnification, etc.) were used in a consistent manner to ensure valid measurements for the artifact sizes. While there are obviously many possible MRI parameters that may be utilized to characterize artifacts for metallic implants, this technique has been presented in many prior reports and, thus, allows comparison to other implants that have undergone similar artifact assessments [2 7]. Importantly, a 3-T/128-MHz MR system was again chosen for this assessment because it represents the highest available static magnetic field currently in clinical use [8]. 6. Evaluation of the effects of MRI at 1.5-T and 3-T on function To determine if the RFID tag part of the access port exhibits a change in function or sustains damage associated with MRI, testing was conducted to evaluate the effects of exposures to the 1.5-T and 3-T static magnetic fields (Part 1) and to various MRI conditions at 1.5-T/64-MHz and 3-T/128-MHz (Part 2), as previously described [3,4,6]. The orientations for the samples and different MRI conditions were implemented to cover a range of possible scenarios with regard to having a patient with this implant undergoing an MRI examination at 1.5-T/64-MHz or 3-T/128-MHz. 6.1. Part 1 Nine samples of the access port with an RFID tag were attached in three different orientations (i.e., axial, sagittal, and coronal orientations three in each position) to a plastic, copper-sulfate-filled phantom. The orientations of the implants were selected to encompass possible clinical placement scenarios for this implant in a patient undergoing an MRI procedure. The phantom with the attached samples was placed on the patient table of the 1.5-T and 3-T MR systems, respectively, and inserted in (i.e., past isocenter and out the back of the scanner to the farthest point) and out (i.e., approximately 0.5-m past the opening of the bore of each MR system) of the scanner 10 times [3,4,6]. Total exposure time to each static magnetic field was 20 min. 6.2. Part 2 Samples of the access port with an RFID tag were again placed on the copper-sulfate-filled phantom in the same manner used for the static magnetic field exposures. MRI was performed at 1.5-T/64- MHz (Magnetom, Software Numaris/4, Version Syngo MR 2002B DHHS Siemens Medical Solutions, Malvern, PA) and 3-T/128-MHz (Excite, Software G3.0-052B, General Electric Healthcare, Milwaukee, WI), using a transmit/receive body radiofrequency coil and eight different pulse sequences, running sequentially, for approximately 2-min per pulse sequence (Table 1) [3,4,6]. The landmarking position (i.e., the center position or anatomic region for the MR imaging procedure) and section locations were selected to encompass all samples to ensure thorough exposure to these MRI conditions [3,4,6].

1442 B. Titterington, F.G. Shellock / Magnetic Resonance Imaging 31 (2013) 1439 1444 Table 1 Parameters used to expose the samples of the access port with an RFID tag to 1.5-T/64-MHz and 3-T/128-MHz MRI conditions. Pulse Sequence #1 #2 #3 #4 #5 #6 #7 #8 T1-SE T2-SE T1-FSE T2-FSE GRE, 3D FGRE, 3D GRE, MTC EPI 1.5-T MRI Conditions TR (ms) 700 3000 700 5000 20 3.7 628 3400 TE (ms) 10 100 12 113 3 1.1 10 103 Flip Angle N/A N/A N/A N/A 25 8 5 N/A Field of View 30 cm 30 cm 30 cm 30 cm 30 cm 30 cm 30 cm 30 cm Section Thickness 10 mm 10 mm 10 mm 10 mm 3 mm 3 mm 10 mm 1 mm Imaging Plane Axial Axial Axial Axial Volume Volume Axial Axial 3-T MRI Conditions TR (ms) 700 3000 700 5000 20 3.7 628 3400 TE (ms) 10 100 12 113 2.7 1.2 10 103 Flip Angle N/A N/A N/A N/A 25 8 5 N/A Field of View 30 cm 30 cm 30 cm 30 cm 30 cm 30 cm 30 cm 30 cm Section Thickness 10 mm 10 mm 10 mm 10 mm 3 mm 3 mm 10 mm 1 mm Imaging Plane Axial Axial Axial Axial Volume Volume Axial Axial (T1-SE, T1-weighted spin echo; T2-SE, T2-weighted spin echo; T1-FSE, T1-weighted fast spin echo; T2-FSE, T2-weighted fast spin echo; GRE, gradient echo; 3D, threedimensional; FGRE, fast gradient echo; MTC, magnetization transfer contrast; EPI, echo planar imaging; N/A, not applicable; GRE, gradient echo; SE, spin echo; SAR, specific absorption rate). The function of each RFID tag was thoroughly evaluated before and after Part 1 and Part 2 conditions and involved comprehensive evaluations performed according to the manufacturer s specifications. 7. Results 7.1. Magnetic field interactions With regard to the findings for magnetic field interactions at 3-T, the mean deflection angle was 4 ±0 and the mean torque value was 0 ± 0 for the access port with an RFID tag. 7.2. MRI-related heating The evaluation of MRI-related heating indicated a highest temperature rise of 1.7 C in association with MRI performed for 15-min at an MR system-reported whole body averaged SAR of 2.9-W/kg. The highest background temperature rise was 1.6 C. 7.3. Artifacts The artifact test results for the access port with an RFID tag are displayed in Table 1. Artifacts appeared as low signal intensity voids that were moderate in size in relation to the size and shape of this implant. The GRE pulse sequence produced larger artifacts than the T1-weighted, spin echo pulse sequence. Fig. 2 shows examples of the artifacts related to the use of the gradient echo pulse sequence for this implant. The maximum size of the artifact as seen on the GRE images extends approximately 15-mm relative to the size and shape of the access port with an RFID tag (Table 2). 7.4. Effects of MRI at 1.5-T and 3-T on function The evaluation of the functional aspects of the RFID tags after exposure to 1.5-T and 3-T static magnetic fields and different MRI conditions at 1.5-T/64-MHz and 3-T/128-MHz indicated that each RFID tag retained its full functionality. Notably, there was no change in the content encoded on each RFID tag and no evidence of damage. Fig. 2. MR images showing artifacts at 3-T for the access port with an RFID tag (gradient echo pulse sequence). A, Section location oriented to the long-axis of the implant. B, Section location oriented to the short axis of the implant.

B. Titterington, F.G. Shellock / Magnetic Resonance Imaging 31 (2013) 1439 1444 1443 Table 2 Summary of MRI artifacts at 3-T for the access port with an RFID tag. Pulse sequence T1-SE T1-SE GRE GRE Signal Void Size 1443-mm 2 1235-mm 2 2414-mm 2 2320-mm 2 Imaging Plane (long axis) (short axis) (long axis) (short axis) (T1-SE, T1-weighted spin echo; GRE, gradient echo). 8. Discussion 8.1. Magnetic field interactions The tests performed to study the magnetic field interactions of the access port with an RFID tag demonstrated that the average deflection angle was 4 and there was no torque. These results are related to the particular materials used to make this implant, which include titanium, polysulfone, silicone, tungsten, and ferrite. Notably, this access port is mostly made from nonmetallic materials, which provide counterweight to the relatively small metallic components (i.e., titanium, tungsten, ferrite) and, consequently, there are relatively low magnetic field interactions. In consideration of this information, there is no risk related to movement or dislodgment of this implant. Accordingly, a patient with this implant can undergo an MRI examination using an MR system operating at 3-T or less [8]. 8.2. MRI-related heating MRI may generate substantial temperature rises in certain metallic implants, resulting in serious patient injuries [8]. Therefore, as a routine procedure to ensure safety in patients with implants that have metallic components, MRI-related heating is evaluated using a standard, in vitro methodology which involves recording temperatures in various positions while subjecting the implant to worst case MRI conditions (i.e., positioning the implant in a phantom that lacks blood flow/ perfusion and using a relatively high whole body averaged SAR for 15-min, simulating an excessive time period for the application of a single pulse sequence) [1 8,10,12]. The findings indicated that the highest temperature change measured for the access port with an RFID tag implant was 1.7 C, while the background temperature rise using the same MRI conditions was 1.6 C. Of note is that most of the small metallic components associated with this implant are encased in nonmetallic, non-conducting materials (i.e., polysulfone and silicone), which essentially insulates and isolates most of the metallic parts (i.e., with the exception of the relatively small connector). Accordingly, excessive MRI-related heating under, even the most extreme MRI conditions, is highly unlikely. The recorded temperature rises will not create a hazard to a patient with this implant under the MRI conditions used for this evaluation. Even though a higher whole body averaged SAR level could have been used for this heating assessment (e.g., whole body averaged SAR, 4-W/kg), this was considered to be adequate for this study. Extrapolating the temperature rise to a whole body averaged SAR of 4-W/kg yields a temperature rise of 2.3 C, which is still an acceptable temperature elevation for a human subject (particularly when one considers body temperature rises related to being in a hot climate or associated with exercise), especially in consideration of the importance of performing a diagnostic MRI examination. 8.3. Artifacts The extent of the artifacts for the access port with an RFID tag implant was somewhat surprising when one considers the outward appearance of this implant (Fig. 1), which seems to have minor metallic components compared with the nonmetallic parts (Fig. 1). However, because of the presence of the ferrite, even a small amount of this material (which is known to have a high magnetic susceptibility) can significantly impact artifact size [11]. For example, Shellock et al. [12] reported the presence of a relatively large artifact for a microstimulator (cylinder-shaped, 16-mm length 2.4-mm diameter creating an artifact area size on GRE images of 3310-mm 2 on the long axis orientation 3214-mm 2 for the short axis orientation) that has a ferrite core. Nevertheless, from a practical view, MRI artifacts created by the access port with an RFID will only present possible issues if the imaging area of interest is in the area where this device implanted (i.e., subcutaneous pocket, in the subclavicular area). If this is an issue, the optimization of pulse sequence parameters can attenuate the artifact size related to this implant [13]. 8.4. Effects of exposures to 1.5-T and 3-T static magnetic fields and MRI conditions at 1.5-T/64-MHz and 3-T/128-MHz For RFID tags, it is vital that these devices exhibit the ability to retain their function after exposure to electromagnetic environments, especially the harsh electromagnetic environments that are associated with MR systems. Therefore, characterizing the functional aspects of an RFID tag that is incorporated in a medical implant is particularly important as part of the MRI testing that is necessary for these devices. In the present study, each RFID tag exposed to static magnetic fields (1.5-T and 3-T) as well as different MRI conditions at 1.5-T/64-MHz and 3-T/128-MHz showed normal function with no evidence of data corruption or damage. Steffen et al. [1] reported similar results from an investigation involving a variety of different RFID tags tested at 1.5-T and 3-T, with the caveat that the findings were specific to the RFID tags that underwent testing [1]. The frequency of the RFID tag compared with the frequency of the MR system must be taken into consideration to ensure that there is no interference generated by the operation of the scanner [1]. 8.4.1. Possible limitations Tests conducted on the access port with an RFID tag involved 1.5-T/64-MHz and 3-T/128-MHz MR systems, only. Therefore, it is unknown if possible adverse interactions, particular with respect to the functional aspects of the RFID tag, can occur in association with scanners operating above or below these particular static magnetic field strengths and frequencies. The decision to use MR systems operating at other field strengths and frequencies in patients with this implant should be made by an MRI-trained radiologist, based on careful consideration of the risk versus benefit for the MRI examination. Furthermore, the long-term effects of the MRI environment (e.g., multiple repeated exposures over and above those used under the conditions described in this study) on the ability of the RFID to function was not in the scope of the present investigation and, thus, this may also be considered a possible limitation. 9. Conclusions A new access port with an RFID tag underwent comprehensive testing for magnetic field interactions, MRI-related heating artifacts, and to determine if the function of the RFID tag was compromised under conditions associated with 1.5 and 3-T MR systems. Based on the results of the tests that were conducted, this implant is acceptable [or, MR conditional, using current MRI labeling terminology [14]] for patients undergoing MRI examinations at 1.5-T/64- MHz and 3-T/128-MHz.

1444 B. Titterington, F.G. Shellock / Magnetic Resonance Imaging 31 (2013) 1439 1444 Acknowledgments Special thanks to Sam Valencerina, B.S., R.T., (R) (MR) for his highly professional and invaluable assistance with the MRI test procedures. References [1] Steffen T, Luechinger R, Wildermuth S, Kern C, Fretz C, Lange J, et al. Safety and reliability of radio frequency identification devices in magnetic resonance imaging and computed tomography. Patient Safe Surg 2010;4:2 11. [2] Shellock FG, Meepos LN, Stapleton MR, Valencerina S. In vitro MRI evaluation of ossicular implants at 3-tesla. Otol Neurotol 2012;33:871 7. [3] Weiland JD, Faraji B, Greenberg RJ, Humayun MS, Shellock FG. Assessment of MRI issues for the Argus II retinal prosthesis. Magn Reson Imaging 2012;30:382 9. [4] Shellock FG, Bedwinek A, Oliver-Allen M, et al. Assessment of MRI issues for a 3- tesla immune programmable CSF shunt valve. Am J Neuroradiol 2011;197: 202 7. [5] Shellock FG, Valencerina S. In vitro evaluation of MR imaging issues at 3-T for aneurysm clips made from MP35N: findings and information applied to 155 additional aneurysm clips. Am J Neuroradiol 2010;31:615 9. [6] Shellock FG, Crivelli R, Venugopalan R. Programmable infusion pump and catheter: evaluation using 3-tesla MRI. Neuromodulation 2008;11:163 70. [7] American Society for Testing and Materials (ASTM) Designation: F2052-06e1. Standard test method for measurement of magnetically induced displacement force on passive implants in the magnetic resonance environment. In: Annual book of ASTM standards, section 13, medical devices and services, volume 13.01 medical devices; Emergency Medical Services. Conshohocken, PA, pp; 1576 1580, 2006. [8] Shellock FG. Reference manual for magnetic resonance safety, implants, and devices: 2013 edition. Los Angeles (CA): Biomedical Research Publishing Group; 2013. [9] Shellock FG, Kanal E, Gilk T. Confusion regarding the value reported for the term spatial gradient magnetic field and how this information is applied to the labeling of medical implants and devices. AJR Am J Roentgen 2011;196:142 5. [10] American Society for Testing and Materials (ASTM) International: F2182. Test method for measurement of radiofrequency induced heating near passive implants during magnetic resonance imaging. West Conshohocken (PA): American Society for Testing and Materials International; 2011. [11] Schenck John F. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys 2006;23:829 33. [12] Shellock FG, Cosendai G, Park S-M, Nyenhuis JA. Implantable microstimulator: magnetic resonance safety at 1.5-tesla. Invest Radiol 2004;39:591 9. [13] Hargreaves BA, Worters PW, Pauly KB, Paly JM, Koch KM, Gold GE. Metalinduced artifacts in MRI. AJR Am J Roentgenol 2011;197:547 55. [14] Shellock FG, Woods TO, Crues JV. MRI labeling information for implants and devices: explanation of terminology. Radiology 2009;253:26 30.