PRESSURE DROP ANALYSIS OF INLET PIPE WITH REDUCER AND WITHOUT REDUCER USING CFD ANALYSIS



Similar documents
FLUID FLOW Introduction General Description

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING

EXPERIMENTAL STUDIES ON PRESSURE DROP IN A SINUSOIDAL PLATE HEAT EXCHANGER: EFFECT OF CORRUGATION ANGLE

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF FORCED CONVECTION FLOW AND HEAT TRANSFER IN A LAMINAR CHANNEL FLOW

EXPERIMENTAL ANALYSIS OF HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE WITH DIFFERENT TWIST RATIO OF TWISTED TAPE INSERTS

Corrugated Tubular Heat Exchangers

MAXIMISING THE HEAT TRANSFER THROUGH FINS USING CFD AS A TOOL

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.6, pp ,

Experiment 3 Pipe Friction

CFD Analysis of a butterfly valve in a compressible fluid

Turbulence Modeling in CFD Simulation of Intake Manifold for a 4 Cylinder Engine

CCTech TM. ICEM-CFD & FLUENT Software Training. Course Brochure. Simulation is The Future

Numerical Investigation of Heat Transfer Characteristics in A Square Duct with Internal RIBS

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

Keywords: Heat transfer enhancement; staggered arrangement; Triangular Prism, Reynolds Number. 1. Introduction

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

Ravi Kumar Singh*, K. B. Sahu**, Thakur Debasis Mishra***

Experimental Study On Heat Transfer Enhancement In A Circular Tube Fitted With U -Cut And V -Cut Twisted Tape Insert

Simulation to Analyze Two Models of Agitation System in Quench Process

Pressure drop in pipes...

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

Review of Heat Transfer Parameters of Serrated Plate Fin Heat Exchanger for Different Materials

ME6130 An introduction to CFD 1-1

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

Department of Chemical Engineering, National Institute of Technology, Tiruchirappalli , Tamil Nadu, India

Application of CFD Simulation in the Design of a Parabolic Winglet on NACA 2412

Prediction of Pressure Drop in Chilled Water Piping System Using Theoretical and CFD Analysis

Optimum fin spacing for fan-cooled heat sinks

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

CFD ANALYSES OF FLUID FLOW AND HEAT TRANSFER IN PATTERNED ROLL-BONDED ALUMINIUM PLATE RADIATORS

3. Prescribe boundary conditions at all boundary Zones:

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts

COMPUTATIONAL FLOW MODEL OF WESTFALL'S 4000 OPEN CHANNEL MIXER R1. By Kimbal A. Hall, PE. Submitted to: WESTFALL MANUFACTURING COMPANY

Dr.A.K.Shaik Dawood. N.V.Kamalesh. Department of Mechanical Engineering, Associate Professor, Karpagam University, Coimbatore , India.

MATLAB AS A PROTOTYPING TOOL FOR HYDRONIC NETWORKS BALANCING

CFD Analysis of a Centrifugal Pump with Supercritical Carbon Dioxide as a Working Fluid

Theoretical and Experimental Investigation of Heat Transfer Characteristics through a Rectangular Microchannel Heat Sink

Pipe Flow-Friction Factor Calculations with Excel

Heat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts

Design and Cost Optimization of Plate Heat Exchanger

CFD Application on Food Industry; Energy Saving on the Bread Oven

HEAT TRANSFER ENHANCEMENT AND FRICTION FACTOR ANALYSIS IN TUBE USING CONICAL SPRING INSERT

CFD ANALAYSIS OF FLOW THROUGH A CONICAL EXHAUST DIFFUSER

Multiphase Flow - Appendices

Express Introductory Training in ANSYS Fluent Lecture 1 Introduction to the CFD Methodology

Effect of design parameters on temperature rise of windings of dry type electrical transformer

Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger

Hydraulic losses in pipes

Introduction: Keywords: CFD, MRF, Blower Angular Orientation

Design and Pressure Loss Reduction in the Hydrogen Flow Heat Exchanger with Tube Bundles

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

CFD Analysis of Sloshing Within Tank

CFD Analysis of Swept and Leaned Transonic Compressor Rotor

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

CFD Analysis of Supersonic Exhaust Diffuser System for Higher Altitude Simulation

A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS

Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card

AERODYNAMIC ANALYSIS OF BLADE 1.5 KW OF DUAL ROTOR HORIZONTAL AXIS WIND TURBINE

CFD ANALYSIS OF CONTROLLABLE PITCH PROPELLER USED IN MARINE VEHICLE

Numerical simulations of heat transfer in plane channel

Customer Training Material. Lecture 2. Introduction to. Methodology ANSYS FLUENT. ANSYS, Inc. Proprietary 2010 ANSYS, Inc. All rights reserved.

HEAT TRANSFER ENHANCEMENT IN FIN AND TUBE HEAT EXCHANGER - A REVIEW

Simulation and Nonlinear Analysis of the Stagnant Polymer Layer in a LDPE Tubular Reactor

Modeling and Numerical Blood Flow Analysis of Tibial Artery using CFD

CASL-U

Natural Convection. Buoyancy force

Water hammering in fire fighting installation

O.F.Wind Wind Site Assessment Simulation in complex terrain based on OpenFOAM. Darmstadt,

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

AIR STREAMS IN BUILDING FOR BROILERS

V. N. Chougule, O. F. Daud, G. R. Gupta, V. H. Shelke, R. V. Ugale (Department of Mechanical Engineering, M. E. S. College of Engineering, India)

International journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

Effect of thermal annealing on the properties of porous silicon

INTRODUCTION TO. Chapter 15

Performance Analysis of Solar Air Heater Using CFD

COMPUTATIONAL FLUID DYNAMICS (CFD) ANALYSIS OF INTERMEDIATE PRESSURE STEAM TURBINE

Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

Comparative Analysis of Gas Turbine Blades with and without Turbulators

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

OpenFOAM simulations of the Turbulent Flow in a Rod Bundle with Mixing Vanes

Model Order Reduction for Linear Convective Thermal Flow

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Effect of Rack Server Population on Temperatures in Data Centers

Effect of Pressure Ratio on Film Cooling of Turbine Aerofoil Using CFD

NUMERICAL SIMULATION OF GAS TURBINE BLADE COOLING FOR ENHANCEMENT OF HEAT TRANSFER OF THE BLADE TIP

Flow in data racks. 1 Aim/Motivation. 3 Data rack modification. 2 Current state. EPJ Web of Conferences 67, (2014)

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

A Comparison of Analytical and Finite Element Solutions for Laminar Flow Conditions Near Gaussian Constrictions

HEAT TRANSFER IM LECTURE HOURS PER WEEK THERMODYNAMICS - IM _1

Transcription:

International Journal of Mechanical Engineering (IJME) ISSN(P): 2319-2240; ISSN(E): 2319-2259 Vol. 4, Issue 3, Apr - May 2015, 85-92 IASET PRESSURE DROP ANALYSIS OF INLET PIPE WITH REDUCER AND WITHOUT REDUCER USING CFD ANALYSIS V.H.BANSODE, ACHARI SWATI NIVRUTTI, PAWAR SAURABH NANDLAL & BHARDANDE NIKITA SANJAY Assistant Professor, Department of Mechanical Engineering, Smt. Kashibai Navale College of Engineering, Pune, Maharashtra, India ABSTRACT A plate heat exchanger uses metal plates to transfer heat between two fluids. The metal plates are made up of stainless steel because of its ability to withstand high temperatures, its strength and its corrosion resistance. PHE is use in industries such as chemical, food and pharmaceutical process and refrigeration. The attempt made in this paper is to study the pressure drop in accessories of plate heat exchanger and to observe which geometry of inlet pipe gives the best results. Using simulation. Computational Fluid Dynamic (CFD) is a tool used in this simulation which consists of ICEM CFD and FLUENT. Volume meshing in ICEM is an important part to be considered before doing simulation in FLUENT as a solver. The velocity for water were calculated using flow rate of 1680m 3 /hour. Inlet dimension of pipe is 500mm and material of pipe is steel. Water is fluid which is passed through pipe. The temperature of water is 25degree Celsius. Thus, this paper presents the simulation of pressure drop at inlet of reducer and without reducer of pipe of plate heat exchanger model. KEYWORDS: Plate Heat Exchanger (PHE), CFD, ICEM, Pressure Drop Analysis INTRODUCTION Over the past quarter century, the importance of plate heat exchanger(phe) in industries all over world has increased rapidly. Heat exchanger is a device in which the flow of thermal energy between two or more fluids at different temperatures. Now-a-days PHE widely used in different industries such as chemical, food and pharmaceutical process and refrigeration due to a many of advantages such as compactness, flexibility, ease maintenance and ability to recover heat at extremely small temperature differences. However, the growth of the process industries include mainly reliable operation and high combination of temperature levels, pressure drop, fouling resistance, hence plate heat exchangers become the fastest growing member of the heat exchanger family. Inlet pipe of Plate heat exchanger is made up of steel. Inlet of pipe is connected to the 2.4 bar motor and outlet of inlet pipe is connected to the PHE. In between inlet and outlet of pipe reducer is installed. Pressure drop is important parameter in pipe flow. Pressure drop generally occurs due to friction, pipe elevation, change in kinetic energy. The pressure drop caused by friction of fluid flow i.e. turbulent flow depends on roughness of pipe. www.iaset.us editor@iaset.us

86 V. H. Bansode, Achari Swati Nivrutti, Pawar Saurabh Nandlal & Bhardande Nikita Sanjay The pressure drop between inlet pipe is calculated by analytical as well as by simulation method. This paper makes a contribution to the overall effort to increase understanding of the behaviour fluid flow in PHE inlet pipe. PROBLEM STATEMENT The Plate Heat Exchanger (PHE) with constant flow rate of 1680m 3 /hr. Water is use as cooling fluid which is at room temperature. Reducer and without reducer inlet pipe of standard dimensions are fitted to heat exchanger. To calculate and analyse of pressure drop occurs between cross-section of pipe pe by using CFD and Mathematical equations. Case 1: Pressure drop using reducer. Case 2: Pressure drop without using reducer (i.e. sudden contraction) THERMAL PROPERTIES OF STAINLESS STEEL Thermal Conductivity = 17 W/m.K Density = 7.93Mg/m 3 Specific Heat =490J/kg.k THERMAL PROPERTIES OF FRESH WATER Thermal Conductivity= 0.604 W/m.k Density =997.4 kg/m 3 Specific Heat= 4181 J/Kg.K MODELLING OF INLET PIPE Modelling is a pre-processor processor tool, modelling of inlet pipe is done in Creo and meshing of inlet pipe is created using the ICEM CFD software. Meshing can be defined as the process of splitting a physical domain into smaller sub domain in order to facilitate the numerical solution of a partial differential equation. Figure 1: Mesh of Inlet Pipe with Reducer Figure 2: Mesh of Inlet Pipe without Reducer Impact Factor (JCC): 3.6234 NAAS Rating: 2.02

Pressure Drop Analysis of Inlet Pipe with Reducer and without Reducer Using CFD Analysis 87 ANALYTICAL CALCULATION Given Data Flow Rate (Q) =1680m 3 /hr Flow Rate (Q) =0.4667 m 3 /s T= 25 D 1 =500 mm D 2 =300 mm SOLUTION A 1 = /4 * (D 1 ) 2 =0.1963 m 2 A 2 = /4 * (D 2 ) 2 =0.07069 m 2 By continuity Equation, Similarly, Q= A 1 V 1 V 1 = Q/A 1 =2.3773 m/s Q=A 2 V 2 V 2 = Q/A 2 =6.6021 m/s REYNOLD S No:- At T= 25, µ = 0.894*10-3 Pas Re=VD/µ For D 1 =500 mm=0.5 m Re 1 =V 1 D 1 /µ Re 1 = 1329586.13 For D 2 = 300 mm=0.3m Re 2 =V 2 D 2 /µ Re 2 =2215469.799 Friction Factor Assuming smooth pipe, For D 1 =0.5m 1/ f =2.03 log 10 (Re 1 f) -0.91.. (Page No-608, Modi & Seth) f= 0.0110031 www.iaset.us editor@iaset.us

88 V. H. Bansode, Achari Swati Nivrutti, Pawar Saurabh Nandlal & Bhardande Nikita Sanjay By Nikuradse s Experiment, 1/ f =2.03 log 10 (Re 1 f )-0.8 f= 0.010774206 For D 1 =0.3m 1/ f =2.03 log 10 (Re 2 f) -0.91 f= 0.010108751 1/ f =2.03 log 10 (Re 2 f) -0.8 f= 0.010203682 Case 1: Pressure drop with reducer. Figure P 1 =2.4 bar.(given) By Darcy Weisbach Equation, For Region 1, h f = flv 1 2 /2gD 1 h f = 0.01585 m P 1 - P 2 /γ =h f P 2 =2.39844 bar P 2 =239844 Pas For Region 2, By Bernoulli s Theorem, P 2 /γ +V 2 1 /2g =P 3 /γ +V 2 2 /2g +h f h f =4fQˆ2lˆ5/2gπ 2 D 5 2 [1/lˆ4-1/(L+l)ˆ4] ( Page No-475,Modi & Seth) h f =0.02128 2.39844*10ˆ5/9810+(2.3773)ˆ2/2*9.81=P 3 /9810+(6.6021)ˆ2/2*9.81+0.02128 P 3 =2.20666 bar Impact Factor (JCC): 3.6234 NAAS Rating: 2.02

Pressure Drop Analysis of Inlet Pipe with Reducer and without Reducer Using CFD Analysis 89 P 3 =220666Pas For Region 3, h f = flv 2ˆ2/2gD 2 h f = 0.112288m P 3 -P 4 /γ= h f 2.20666*10ˆ5 P 4 /9810=0.112288 P 4 =2.19564 bar P 4 = 219564 Pas Case 2:- Pressure drop without reducer. For Region 1 P 1 =2.4 bar.(given) Figure h f = flv 1 2 /2gD 1 h f =0.01585 (P 1 -P 2 )/γ=h f P 2 =2.39844 bar For Region 2 P 2 /γ+v 2 1 /2g=P 3 /γ+v 2 2 /2g+h L Assume Coefficient of Contraction(Cc)=0.5 h L =V 2 2 /2g[1/Cc-1] 2 h L =2.2216 m 2.39844*10 5 /9810+2.3773 2 /(2*9.81)=P 3 /9810+6.6021 2 /(2*9.81)+2.2216 P3=1.99082 bar For Region 3 h f =FLV 2 2 /2gD 2 www.iaset.us editor@iaset.us

90 V. H. Bansode, Achari Swati Nivrutti, Pawar Saurabh Nandlal & Bhardande Nikita Sanjay h f =0.112288 m P 3 -P 4 /γ=h f 1.99082*10 5 -P 4 /9810=0.112288 P 4 =1.97980 bar CFD ANALYSIS Case1: Pressure drop with Reducer Figure 3: Graph of Pressure Drop in Pipe with Reducer Case 2:- Pressure drop without reducer Figure 4: Variation of Pressure in Pipe with Reducer Using CFD Fluent Impact Factor (JCC): 3.6234 NAAS Rating: 2.02

Pressure Drop Analysis of Inlet Pipe with Reducer and without Reducer Using CFD Analysis 91 Figure 5: Graph of Pressure Drop in Pipe without Reducer RESULT following table. Figure 6:- Variation of Pressure in Pipe without Reducer Result of Pressure drop with reducer and without reducer by Analytical analysis and CFD analysis shown in Pressure Drop with Reducer Pressure Drop without Reducer Analytical Analysis CFD Analysis Analytical Analysis CFD Analysis P 2 2.39844bar 2.38e 5 bar 2.39844bar 2.39e 5 bar P 3 2.20666bar 2.19e 5 bar 1.99082bar 1.97e 5 bar Pressure drop (P 2 -P 3 ) 0.19178bar 0.19e 5 bar 0.40762bar 0.42e 5 bar DISCUSSIONS Thus the CFD result is calculated for inlet with reducer and without reducer. The pressure drop for inlet pipe with www.iaset.us editor@iaset.us

92 V. H. Bansode, Achari Swati Nivrutti, Pawar Saurabh Nandlal & Bhardande Nikita Sanjay reducer is 0.19e 5 bar and that for without reducer is 0.42e 5 bar which is more than with reducer inlet pipe. Whereas analytical results are 0.19178 bar for with reducer and 0.40762 bar for without reducer inlet pipe. Therefore range of variation for analytical and CFD results is within 5%. Hence results are validated. Now, from result, the pressure drop with reducer is less than pressure drop without reducer. Hence its observed that inlet pipe with reducer is better as compared to inlet pipe without reducer. CONCLUSIONS After performing all the analysis work for inlet pipe with reducer and without reducer the following observation had been done. From study of result as mentioned in table, after performing the calculation the pressure drop of inlet pipe with reducer and without reducer are 0.19178bar and 0.40762bar respectively which is nearer to the value mentioned in CFD analysis. As we change inlet pipe from with reducer to without reducer, the pressure drop (P 2 -P 3 ) had been varied. Analysis has been done by varying the inlet pipe and it is found that inlet pipe with reducer gives better pressure drop than inlet pipe without reducer. REFERENCES 1. Takeshi Hara, Research on pipe flow in manifold block, The Proceedings on Spring Conference of Fluid Power System Society, 2010, pp 4-6. 2. Osamu ABE, Tetsuhiro TSUKIJI, Takeshi HARA, Pressure drop of pipe flow in manifold block, The Proceedings of the 8 th JFPS International Symposium on Fluid Power, OKINAWA 2011. 3. A.G. Kanaris, A.A. Mouza, S.V. Paras, Flow and heat transfer prediction in a corrugated plate heat exchanger using a CFD code, Chem. Eng. Technol. 8 (2006) 923e930. 4. S. Jun, V.M. Puri, 3D milk-fouling model of plate heat exchangers using computational fluid dynamics, Int. J. Dairy Tech. 84 (4) (2005). 5. ]Y. Wang, Q.W. Dong, M.S. Liu, D. Wang, Numerical study on plate-fin heat exchangers with plain fins and serrated fins at low Reynolds number, Chem. Eng. Technol. 32 (8) (2009) 1219e1226. 6. B.Jayachandriah1, K. Rajasekhar, Thermal Analysis of Tubular Heat Exchangers Using ANSYS, International Journal of Engineering Research Volume No.3 Issue No: Special 1, pp : 21-25 7. Colebrook CF, Turbulent flow in pipes, with particular reference to the transition region between the smooth and rough pipe laws, J. Inst. Civil. Eng. (LONDON), 11:133 Impact Factor (JCC): 3.6234 NAAS Rating: 2.02