FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST



Similar documents
Notes. Material 1. Appropriate Flammable Liquids

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

FIRE SAFETY ONLINE TRAINING

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

Name Of Occupancy Date. Yes No Describe

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

A. Fire Protection Plan. B. Access and Parking

Spray Booth Guideline

1.0 Purpose Definitions Hot Work Operations. 5

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

Town of Bellingham Fire Department

CANTON FIRE DEPARTMENT

General Fire Code Requirements Within Commercial Tenant Spaces

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

Fire Safety Log Book

Winnipeg Fire Department Fire Prevention Branch

The terms hazard and risk are often used, which we define as the following:

HOT WORK PERMIT PROGRAM TRAINING. John Braun

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

Sample Written Program. For. Flammable Liquids

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

HOT WORK PERMIT PROCEDURES

Pressure Vessels (Air Compressors) and LPG Tanks

EXAMPLE EMERGENCY ACTION PLAN FOR SMALL BUSINESSES

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

FIRE SAFETY HANDBOOK

Fire Safety Risk Assessment Checklist for Residential Care Premises

SAFETY SELF-INSPECTION PROGRAM

Course of Construction Questionnaire

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

NORTH BIRMINGHAM ACADEMY

Orange County Fire Rescue Division Fire Loss Management Bureau 109 East Church Street Lower Level Orlando, Florida

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

ADMINISTRATIVE SERVICES MANUAL

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Emergency Evacuation Plan: 232 King St.

HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME

READ FIRST. Confined Space Entry Procedure. San José State University Environmental Health and Safety. Confined Space Entry Procedure

PLAN REVIEW GUIDE FOR FIRE ALARM

Housekeeping and Material Storage

FIRE RISK ASSESSMENT

Safe Operating Procedure

Flammable Liquids Storage

LABORATORY SAFETY INSPECTION CHECKLIST

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Safety Inspection Checklist

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

Fire Protection Plan

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

FIRE PREVENTION PLAN

Commercial Fire Inspections

Flammable and Combustible Liquids. Slide 1 (of 23)

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION

Flammable Liquids Storage

Fire Safety Plan University Stadium

Flammable Liquids 29 CFR

Fire Safety PROCEDURES January 2011

Fire Risk Assessment Safety Checklist

Fire Alarm System Plans Review Checklist Property location Date of Review

Risk Engineering Guideline

An inventory of hazardous materials used in your workplace will prove useful.

Compressed Gas Cylinder Storage and Handling Guide

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Fire Safety Log Book. Premises Name: Premises Address: Date From: Date To: Location of Log Book:

Master Workplace Inspection Checklist for General Shop Safety. MASTER WORKPLACE INSPECTION CHECKLIST General Shop Safety

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Fire Safety in Laboratories. University of Tennessee Environmental Health and Safety

Safety Checklist. Apartment buildings and condominiums. AvivaCanada.com/risks

Fire Regulations for Exhibitors

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

EMERGENCY ACTION AND FIRE PREVENTION PLAN

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

OREGON FIRE CODE Interpretations and Technical Advisories

CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau

RISK MANAGEMENT QUARTERLY BUILDING REPORT Fire Safety Self -Inspection Checklist

HealthandSafetyOntario.ca. What is a work permit? Why use a work permit? Types of work permits. When is a work permit needed?

STCC Contractor/Vendor Rules and Regulations

Department: Manager: Safety Coordinator: Date:

Monthly Inspection Checklists

WORKSAFE VICTORIA A HEALTH AND SAFETY SELF-ASSESSMENT CHECKLIST FOR SMALL BUSINESS

Family Emergency Preparedness Plan

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

Installation Instructions for Alarm Module Kit A043F059

1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;

Model Safety Program

Transcription:

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result of the review: For each checklist item: If the item inspected is satisfactory, check the OK box If a deficiency is identified, complete the Comments section and indicate the Action Taken If the item does not apply, check the N/A box Imminent Hazards: If a serious hazard is encountered which cannot be immediately abated without endangering employees and/or property, contact your supervisor or facilities manager immediately. All exposed employees should be removed from the area or protected until the hazard is corrected. Many of the inspection points are based upon various National Fire Protection Association (NFPA) standards that may apply to facilities and operations of the organizations. The purpose of the NFPA Code is to prescribe minimum requirements necessary to establish a reasonable level of fire safety and property protection from the hazards created by fire and explosion. This checklist does not include all potential hazards. During your inspection, look for all unsafe conditions or potential hazards. Use the Other Observations and Additional Comments section (end of checklist) to record your observations. This report and recommendations are purely advisory and for the purpose of assisting with fire and loss prevention procedures. Observations and recommendations are the result of practices and conditions observed and information made available at the time of the inspection and do not purport to refer to or guarantee compliance with local, state or federal regulations which may be applicable to such practice and conditions. This report should not be considered a definitive listing of all existing hazards nor an absolute solution to all indicated hazards. Implementation, management and operation of risk control and safety procedures are the responsibility of the organization. 1

Fire Prevention - All Facilities Fire extinguishers inspected monthly and serviced by contractor annually Portable space heaters have automatic shut off feature if tipped over Personal electric appliances inspected for safety before being used in workplace Emergency telephone number posted in clear and conspicuous locations Extension cords are used minimally and are temporary Flammable or combustible liquids not stored in building Trash is removed at least daily from building Fire and smoke detection systems inspected and serviced Building exterior is free of trash and combustible debris Fire Prevention - Buildings with Automatic Sprinkler Systems Sprinkler control valves are secured in open position Fire department connections are capped and secured Spare sprinkler heads and tools are readily available and accessible Sprinkler heads are at least 18 above stored material Main drain flow test is performed on system annually Inspector s test valve is opened at least every 2 years Gauges are inspected and operating properly as applicable Alarm device is operating and sounds to responding authority when activated 2

Building Utilities Electric circuit breaker panels kept clear at least 36 in front of panel All circuit breakers in panel are identified to show which circuits they power Electric panels are accessible by trained and authorized personnel Gas main feed identified, kept clear of debris and protected from physical damage Gas main shut off tools readily available and authorized person trained to use tools Emergency and Standby Power Systems (ESPS) ESPS exercised at least once monthly by trained and authorized personnel, recorded in log Transfer switches operated monthly by authorized personnel, recorded in log Main & feed breakers are exercised annually Emergency power set has at least 2 sets of instructions manuals Special tools and testing devices for ESPS are available to trained and authorized personnel Replacement parts for high mortality items are readily available Written maintenance and operational testing program established and documented Transfer switches are included in maintenance program Storage batteries inspected at intervals not more than 7 days 3

Record File Room - Fire Protection Vital records are not stored in file room Walls have no openings other than necessary for access File room door has fire rating equiv. to that of walls Door has closing device connected to smoke sensors File room has no pendant lamps or extension cords All records kept in cabinets are at least 3 above floor Fire extinguisher kept outside door of file room File room is not used as a working space Record Storage Vaults Fire Protection Vault wall penetrations are small and sealed Vault door has fire resistance rating equivalent to vault walls Vault has no pendant lamps or extension cords Records kept in fully enclosed non-combustible containers All records kept in cabinets are at least 3 above floor Before closing vault, all record containers are closed Before closing vault, all paper waste is removed Vault is not used as a working space Records are kept at least 18 below sprinkler deflectors 4

Fire extinguisher kept outside door of vault Computer Room Fire Protection Access is restricted to only persons absolutely necessary to operation of equipment Written emergency fire plan prepared and posted inside and near computer room Computer room not located above/below hazardous areas Structural supports and raised floor decks - noncombustible Deck access tools to remove panels are in room and well marked Under-floor cable openings provided with fire stops of approved sealant Office tables and desks in room are metal construction Only self-extinguishing trash receptacles used in room Only records essential to computer operations are kept in computer room Records storage rooms are separate from computer room Paper stock and other media restricted to absolute minimum Automatic smoke and fire detection system annunciate at constantly attended location Fire extinguishers indicate the type of fire for which it is intended Gaseous total flooding system serviced and tested as recommended by installer Changes to computer room configuration approved by detection and extinguishing system installer Steam, water or drain piping should not be in place over computer room 5

Equipment and Vehicle Storage Facilities When liquefied natural gas fueled vehicles are repaired or stored, open flame heaters are not permitted Suspended heaters are not less than 8 ft. above floor Flammable spray painting not conducted near open flame or spark producing devices Parts cleaning solvent is non flammable or no ignition source in the area Fuel tanks drained and purged or inerted prior to work Combustible rubbish placed in covered metal receptacles and removed daily Oily rags kept in metal container with self closing cover Fire extinguishers are adequate for exposure and in clear and conspicuous places Storage of Flammable Materials Flammable gasses stored at least 20 from oxygen gas Open flames not permitted in flammable storage areas Liquified flammable gas cylinders stored upright or that pressure relief valve in direct contact with vapor space Approved storage cabinet used for flammable liquid storage 6

Emergency Action Plans Emergency escape procedures and emergency route assignments are written and posted Procedures established for designated employees who may operated critical operations before they evacuate Procedures established to account for all employees after emergency evacuation has been completed Rescue and medical duties established for those employees who are to perform them Emergency reporting procedures and emergency notification telephone numbers established and posted Names or job titles or departments who can be contacted for further information or explanation of duties under emergency action plan Training has been provided for a sufficient number of persons to assist with emergency evacuation Review conducted with each employee upon initial assignment regarding emergency action plan Emergency Preparedness Location of emergency supplies and materials, 1 st aid kits have been identified and inspected Heavy objects are placed below 42 to avoid them falling on person during earthquake Racks, shelves, and cabinets are secured from tipping during earthquake Evacuation practice drills are conducted as necessary Emergency egress route kept clear and exits have been identified Emergency evacuation plan for people with disabilities established and communicated 7