MONTE CARLO SIMULATION OF THE FULL MULTIPLICITY DISTRIBUTIONS MEASURED WITH A PASSIVE COUNTER



Similar documents
Open Source Software zur Vertrauensbildung in der Abrüstungsverifikation: Simulation von Neutronenmultiplizitätsmessungen mit Geant4

Neutron Detection Setups proposed for

DEVELOPMENT OF A DYNAMIC SIMULATION MODE IN SERPENT 2 MONTE CARLO CODE

Evaluation of 55-gallon Lead-Lined Calibration for the Gamma Modality of the High Efficiency Neutron Counter

WM2012 Conference, February 26 -March 1, 2012, Phoenix, Arizona, USA

Basics of Nuclear Physics and Fission

ENRICHMENT AND URANIUM MASS FROM NMIS FOR HEU METAL

Michael I. Frank and James K. Wolford, Jr. Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA ABSTRACT

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

Radioactivity III: Measurement of Half Life.

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

PROSPECT: Precision Reactor Oscillation and Spectrum experiment

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

Calculation of Source-detector Solid Angle, Using Monte Carlo Method, for Radioactive Sources with Various Geometries and Cylindrical Detector

Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using GATE

Nuclear Criticality Safety Division TRAINING MODULE CSG-TM-016 COG SOFTWARE

Public Policy 290 Homeland Security / Cyber Security. Fall US program to address nuclear terrorism threats:

Visualization of Output Data from Particle Transport Codes

V K Raina. Reactor Group, BARC

DEMONSTRATION ACCELERATOR DRIVEN COMPLEX FOR EFFECTIVE INCINERATION OF 99 Tc AND 129 I

A Tool for Criticality Accident Emergency Planning, Training and Response

Variance Reduction Techniques for the Monte Carlo Simulation of Neutron Noise Measurements

Dynamic Load Balancing of Parallel Monte Carlo Transport Calculations

Physics Simulation and Configuration Control in support of the Operation and Ageing Management of SAFARI-1

Application Guide to Shufflers

MCQ - ENERGY and CLIMATE

Objectives 404 CHAPTER 9 RADIATION

Advanced Safeguards Measurement, Monitoring and Modelling Laboratory (AS3ML) at JRC-ITU-Ispra

About the Enrichment Limit for Research Reactor Conversion : Why 20%?

A VERSATILE COUNTER FOR CONVERSION MÖSSBAUER SPECTROSCOPY

[2] At the time of purchase of a Strontium-90 source, the activity is Bq.

How To Understand The Sensitivity Of A Nuclear Fuel Cask

Application Guide to Gamma-Ray Isotopic Analysis Using the FRAM Software

Status of REBUS Fuel Management Software Development for RERTR Applications. Arne P. Olson

Authors:

Pedestrian and post-luggage monitors. Vehicle monitors. Mobile monitors. Integrated monitoring system

IAEA Support for the Establishment of Nuclear Security Education

A Comparison of an HPGe-based and NaI-based Radionuclide Identifier (RID) for Radioactive Materials

The data acquisition system of the XMASS experiment

Joint Application of Perl Scripts and MCNPX in Solving the Dynamic-Geometry Related Problems in Proton Beam Radiotherapy

A Review of Emerging Gamma Detector Technologies for Airborne. Radiation Monitoring

Perspectives of a method for measuring soil-gas radon by an opened counting vial

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

Applying Digital Library Technologies to Nuclear Forensics

THE STATISTICAL TREATMENT OF EXPERIMENTAL DATA 1

EXPERIMENTAL CONDITIONS FOR CROSS SECTION MEASUREMENTS FOR ANALYTICAL PURPOSES. L. Csedreki 1. Abstract. I. Introduction

Overview of Nuclear Detection Needs for Homeland Security. Abstract

WORLD CUSTOMS EXHIBITION AND FORUM, Budapest, th September 2003

KAZAN FEDERAL UNIVERSITY INSTITUTE OF PHYSICS DETECTING RADIOACTIVITY RECORDING THE CHARACTERISTIC OF A GEIGER-MÜLLER COUNTER TUBE

Cosmic Ray Muon Scattering Tomography for Security Applications

Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

Accidents of loss of flow for the ETTR-2 reactor: deterministic analysis

ABSORPTION OF BETA AND GAMMA RADIATION

History of the Atom & Atomic Theory

Structure and Properties of Atoms

10 Nuclear Power Reactors Figure 10.1

arxiv: v1 [physics.ins-det] 14 Jan 2014

Lecture 2 Macroscopic Interactions Neutron Interactions and Applications Spring 2010

Categorisation of Active Material from PPCS Model Power Plants

Christopher M. Perfetti, PhD

Válido - Uso Interno LEUPA CRITICALITY ANALYSIS. Type B(U) Package to Contain Fissile Substances. Documento No: 0908-LE01-3BEIN-024-A Revision: A

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Chemistry 1000 Lecture 2: Nuclear reactions and radiation. Marc R. Roussel

Prentice Hall. Chemistry (Wilbraham) 2008, National Student Edition - South Carolina Teacher s Edition. High School. High School

Plutonium vs. Uranium: The Road Less Traveled. In a world where nuclear proliferation may no longer be held back by the guise of antiproliferation

Radiation Protection s Benefits in the Production of Iodine-131

DOE FUNDAMENTALS HANDBOOK

LA-UR- Title: Author(s): Submitted to: Approved for public release; distribution is unlimited.

A Digital Spectrometer Approach to Obtaining Multiple Time-Resolved Gamma-Ray. Spectra for Pulsed Spectroscopy. W. K. Warburton a

1. In the general symbol cleus, which of the three letters. 2. What is the mass number of an alpha particle?

Instructors Guide: Atoms and Their Isotopes

SECTION TWO PACKAGING, TRANSPORTATION AND STORAGE OF RADIOACTIVE MATERIALS

Transport Test Problems for Hybrid Methods Development

Eddy-current testing - Non-destructive testing for flaw detection of metals, coatings and carbon fibres

THE COMPARISON OF THE PERFORMANCE FOR THE ALLOY FUEL AND THE INTER-METALLIC DISPERSION FUEL BY THE MACSIS-H AND THE DIMAC

ALGORITHM TO DETERMINE THE CALIBRATION PARAMETERS FOR A NDA METHOD OF INVENTORY VERIFICATION IN A DIFFUSION ENRICHMENT CASCADE

Forensic Science Standards and Benchmarks

CRITICALITY ACCIDENT ALARM SYSTEM MODELING WITH SCALE

Gamma Ray Detection at RIA

Attribute Measurement System with Information Barrier (AMS/IB) Conceptual Description

Appendix A. An Overview of Monte Carlo N-Particle Software

Homework #10 (749508)

Industrial tracers - Finding leaks and blockages

The International Monitoring System noble gas network Matthias Auer, CTBTO, Vienna

The accurate calibration of all detectors is crucial for the subsequent data

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

ISTITUTO NAZIONALE DI FISICA NUCLEARE

Radiation Detection and Measurement

Atomic and Nuclear Physics Laboratory (Physics 4780)

Discovery of neutrino oscillations

For convenience, we may consider an atom in two parts: the nucleus and the electrons.

Using Monte Carlo method for simulation of electromagnetic radiation penetration in body ' s tissues

ABSTRACT INTRODUCTION

E190Q Lecture 5 Autonomous Robot Navigation

Significant incidents in nuclear fuel cycle

Masses in Atomic Units

COMPLETE USER VISUALIZATION INTERFACE FOR KENO

Transcription:

International Conference on Mathematics, Computational Methods & Reactor Physics (M&C 9) Saratoga Springs, New York, May 3-7, 9, on CD-ROM, American Nuclear Society, LaGrange Park, IL (9) MONTE CARLO SIMULATION OF THE FULL MULTIPLICITY DISTRIBUTIONS MEASURED WITH A PASSIVE COUNTER E. C. Miller, S. D. Clarke, M. Flaska, and S. A. Pozzi Department of Nuclear Engineering & Radiological Sciences University of Michigan Ann Arbor, MI 819 ericcm@umich.edu; clarkesd@umich.edu; mflaska@umich.edu; pozzisa@umich.edu P. Peerani Joint Research Commission Ispra, Italy paolo.peerani@jrc.it ABSTRACT The objective of the work here is to validate the Monte Carlo code MCNP-PoliMi using comparisons with experimental data for the specific problem of neutron multiplicity counting with He-3 detectors. Measurements of various fissionable samples have been made with an active well coincidence counter (AWCC) operating in passive mode at the PERLA laboratory at Joint Research Center site in Ispra, Italy. The MCNP-PoliMi postprocessor was upgraded to explicitly simulate the deadtime in the PERLA measurement electronics. The results from MCNP-PoliMi have been compared to the measured data from 5 Cf sources and several plutonium and plutonium oxide samples. Very good agreement between the simulated and measured multiplicity distributions has been observed for multiplet orders as high as 5. Key Words:, MCNP, MCNP-PoliMi 1. INTRODUCTION The distinction of fissile material from benign material is of great concern to the United States and the world. The principal difference between fissile and benign materials is neutron multiplication. Consider the decay of a material in the presence of a detection system capable of accurately recording the emissions: for a benign material, such as lead, the reaction emissions would largely be single-particle in nature whereas a fissile material would undergo multi-particle chain reactions. The result would be many particles (neutrons and photons) arriving at the detectors within a given time window. Such a grouping of particles is referred to as a multiplet. The distribution of these multiplets holds important information regarding the nature of the interrogated sample. counting has been well established as an assay method for plutonium samples in the area of nuclear materials control and accountability [1-3]. The multiplicity distributions are acquired by specialized electronics packages that separately record the number of times specific numbers of neutrons are detected during a fixed time window. These passive counting systems

E. C. Miller, S. D. Clarke, M. Flaska, et al. rely on neutrons emitted by spontaneous fission; these neutrons are typically counted using polyethylene-moderated 3 He proportional counters []. Previous work has been done validating Monte Carlo codes with experimental multiplicity data [5, 6]. The objective of the work here is to use this experimental data to validate the Monte Carlo code MCNP-PoliMi for the specific problem of neutron multiplicity counting. Passive measurements of various fissionable samples have been made with an active well coincidence counter (AWCC) operating in passive mode at the PERLA laboratory at Joint Research Center site in Ispra, Italy. These results will be compared to Monte Carlo simulations and the system performance will be assessed.. MONTE CARLO MODELING Monte Carlo codes have been widely used to design and analyze measurement systems of many types and configurations. However, when modeling the time-correlated events resulting from fission reactions and chains, the widely-used Monte Carlo code MCNPX has some limitations. Therefore, the MCNP-PoliMi code was chosen for the simulations here..1. Description of the MCNP-PoliMi Code In standard MCNPX it is only possible to simulate a single source neutron per history making accurate simulation of neutron multiplicity distributions extremely difficult. [7]. An enhanced version of MCNPc, MCNP-PoliMi, preserves standard MCNP code structure while correcting this deficiency, although it introduces some assumptions [8]. MCNP-PoliMi is capable of simulating multiple correlated source neutrons from a single history (e.g. a spontaneous fission event). These source neutrons are sampled from a multiplicity distribution to ensure that the correct numbers of particles with appropriate energies are created.. MCNP-PoliMi version 1.. is capable of running with all standard MCNP source types and includes several specific spontaneous-fission-source definitions (i.e., 5 Cf, Pu, Pu, Cm, Cm), as well as (, n) sources from plutonium isotopes as well as 1 Am. These distributions contain accurate representations of the energy and multiplicity distributions of both neutrons and gamma rays. MCNP-PoliMi produces a specialized output file that includes a detailed account of all interactions occurring within certain geometric cells specified by the user; these cells typically correspond to the radiation detectors in the system. A specialized post-processing code is then used to process this output to generate the response from a given radiation detector. This code has been recently extended to model detection in a 3 He multiplicity counter [9]. An extended deadtime module has been developed to apply this model to an active well coincidence counter... MCNP-PoliMi Model Description The Canberra JCC-51 active well coincidence counter (AWCC), shown in Figure 1, consists of 3 He neutron detectors imbedded in polyethylene in a cylindrical arrangement around a central sample cavity with AmLi neutron sources above and below. The AWCC was modeled completely in MCNP-PoliMi with the exception of the AmLi sources because the experiments were performed in passive mode. A total of six different samples were measured at PERLA: low- /1

Monte Carlo Simulation of Full Distributions intensity 5 Cf, high-intensity 5 Cf, Pu metal, small-volume PuO powder, large-volume PuO powder and mixed-oxide (MOX) powder. The various fissionable sample sources were modeled with as much detail as possible including all appropriate spontaneous fissions and (, n) contributions. Any casings or containers were also modeled in order to reflect as much of the PERLA experiment as possible. Source emissions were evenly distributed in time over approximately 1 s (the data collection time in the measurements). The total number of Monte Carlo source histories for each simulation was calculated using the exact experimental data collection times and the activity of each sample. The sample activity was calculated using the sample mass and the spontaneous fission and (, n) specific activities. Source contributions that were less than 1% of the total were neglected; the total source activities were re-normalized to account for these small approximations. Figure 1. MCNP-PoliMi model of a Canberra JCC-51 active well coincidence counter. 3. Description of the Post Processor The MCNP-PoliMi postprocessor was upgraded to explicitly simulate the deadtime in the PERLA measurement electronics. The enhanced post processing code operated in three distinct stages. The first stage removed all events from the PoliMi output file that were not neutron captures on helium occurring inside of the 3 He tubes. The remaining events are then sorted according to their time of interaction. Next, the event times are processed through the measurement circuit electronics of the detector system (see Figure ). The measurement electronics system divides the 3 He tubes into six groups of seven detectors each. The signal from each detector group is sent to a separate amplifier. Then, the signal from each amplifier is collected in a single OR gate. The deadtime of each 3 He tube was modeled individually. Once an event occurred in a live tube, the amplifier associated with that tube is checked (the dead times of the six amplifiers were also modeled individually). If the amplifier is dead, the pulse was rejected and if the amplifier is live, the status of the OR gate was checked. If the OR gate is dead then the pulse was rejected otherwise it is accepted. The output of this post-processing step is a list of acceptable pulses (those which occur in a live tube, amplifier and OR gate). 3/1

E. C. Miller, S. D. Clarke, M. Flaska, et al. Figure, Circuitry of the detector system. The final stage of the postprocessor applies the shift register analysis (see Figure 3) to the list of acceptable pulses to determine the multiplicity distribution. The shift register activates on a trigger pulses then looks back in time and counts the previously received pulses. This is done by applying a short predelay, -.5 μs, then opening a -6-μs window relative to the initial trigger pulse. Events recorded in this time window contribute to the total multiplicity distribution (reals plus accidentals (R+A)). The shift register also opens a second -6 μs window at -1 μs relative to the trigger pulse. Counts recorded in this second window contribute the background accidental distribution (A). This intent for opening this second window after a long delay is that the initial spontaneous fission neutrons will no longer be present in the system. Therefore, the background rate of neutrons can be measured. The postprocessor cycles through all of the acceptable pulses and treating each pulse as a trigger pulse, building the complete R+A and A distributions. Figure 3, Shift Register The PERLA measurement data contained only the times of events recorded. Consequently, the effects of the electronics were not needed. Therefore, the PERLA data were read directly into the final portion of the post processing to apply the shift register calculation. /1

Counts Monte Carlo Simulation of Full Distributions. RESULTS The experimental data were collected at the PERLA laboratory at the Joint Research Centre site in Ispra, Italy for six different sources measured in ten 1-s measurements. The R+A and A distributions from the MCNP-PoliMi simulated data and PERLA measured data were generated using the enhanced postprocessor and then compared for each of the six measurement sources..1 Low-intensity 5 Cf source The first of the six samples measured was a weak source of 5 Cf with an activity of 3781 n/s. This source was modeled as an isotropic point source at the center of the AWCC cavity. The casing around the source was neglected. 1 x 1 Cf source (3781 n/s) Multiplicty Distribution 1 1 8 6 Figure, distribution comparison for weak 5 Cf source (3781 n/s) Figure shows that the simulated distributions for the weak 5 Cf source are very close to the distributions from the measured PERLA data. This shape of the R+A distribution is as expected for a weak source of spontaneous fission neutrons. Most of the trigger events are uncorrelated neutrons; this is shown by the zero-order multiplet being the most probable. The accidentals distribution shows that after an extended time after the trigger pulse the most probable number of counts in the 6 μs window is also zero, which is also expected for a low activity source.. High-intensity 5 Cf source 1 3 5 The second source that was measured in this measurement campaign was 5 Cf with an activity of 97 n/s. This source was also small enough that is was modeled as an isotropic point source located in the center of the AWCC cavity. The casing of the source was again neglected. 5/1

Counts E. C. Miller, S. D. Clarke, M. Flaska, et al. 18 x 15 Cf Source (97 n/s) Multiplicty Distribution 16 1 1 1 8 6 Figure 5. Comparison of PERLA experimental results to MCNP-PoliMi simulation for a 97 n/s 5 Cf source in an passive well coincidence counter. Figure 5 shows excellent agreement observed between the MCNP-PoliMi results and the PERLA experiment, up to multiplet-orders as high as 5 for both the R+A and A distributions. The shape of the distribution is expected for sources with such a high activity: for every trigger event, some additional neutrons will be recorded in the counting window. For this case, nine neutrons inside of the 6-μs window was most probable number in the R+A distribution. The accidentals distribution is very similar to the R+A distribution but shifted slightly towards lower multipletorders. This is expected because of the long delay between the trigger pulse and the opening of the accidental window, this decreases the chance of detecting events correlated with the initial trigger..3 Plutonium metal disk The third source was a plutonium metal disk at the center of the AWCC cavity. This metal disk was a PuGa alloy (1.5% Ga),.6-cm thick and 3.3 cm in diameter. The plutonium certified mass was 9.55 g. The isotopic composition was.13% 38 Pu, 75.66% 39 Pu, 1.9% Pu, 1.95% 1 Pu and.77% Pu with an Am/Pu ratio of.186. These isotopics were measured in July, 1996 [1].. 5 1 15 5 6/1

Counts Monte Carlo Simulation of Full Distributions x Pu Metal Disk Multiplicty Distribution 1 1 9 8 7 6 5 3 1 1 3 5 Figure 6, Comparison of multiplicity distributions for the Pu metal disk Figure 6 shows only a slight deviation between the PERLA measurements and the MCNP- PoliMi simulation multiplet-order zero, but the higher-order multiplets are all within statistical error. The plutonium metal disk has a calculated sample activity of 3 n/s, a low activity, which is verified by the shape of the R+A distribution. The R+A distribution shows a rapid decrease, with almost no counts greater than multiplet-order four. The accidental distribution matches the behavior shown by the low-activity 5 Cf source.. Small sample of plutonium oxide powder The fourth measured sample was a small sample of plutonium oxide powder with a total mass of 59.13 g and an estimated density of.6 g/cm 3. This source was placed on a 1-cm aluminum ring placed inside the AWCC cavity. This sample was inside of a model- container which consists of two AISI-3 stainless steel cylinders. These details were included in the MCNP-PoliMi simulation. The plutonium certified mass was 5.339 g, the isotopic composition was.17% 38 Pu, 7.53% 39 Pu, 5.7% Pu, 1.3% 1 Pu and 1.% Pu, with an Am/Pu ratio of.31. These isotopics were measured in August, 8. 7/1

Counts Counts E. C. Miller, S. D. Clarke, M. Flaska, et al. 6 x 15 Small Sample of Pu Oxide Multiplicty Distribution 5 3 1 1 3 5 Figure 7, Comparison for the Small sample of Pu Oxide Figure 7 shows excellent agreement between the PERLA measured data and the MCNP-Polimi simulated data for the R+A distribution and the A distribution up to a multiplet-order five. This sample had a calculated source activity of 556 n/s. Therefore, most of the trigger events do not have any subsequent events and the distribution drops nearly to by multiplet-order five. The trend in the accidental distribution is similar to the other low-activity sources..5 Large sample of plutonium oxide powder The fourth measured sample was a small sample of plutonium oxide powder with a total mass of 118.96g and the same composition as the small plutonium oxide sample. This sample was inside of a model-1 container (a larger version of the model-) that was placed on the bottom of the AWCC cavity. This source has a calculated source activity of 383 n/s, making this the second-strongest source measured in this measurement campaign. 18 x 15 Large Sample of Pu Oxide Multiplicty Distribution 16 1 1 1 8 6 5 1 15 5 Figure 8, Comparison of multiplicity distributions for the large sample of Pu oxide 8/1

Counts Monte Carlo Simulation of Full Distributions Excellent agreement is observed in Figure 8 for both the R+A and A distributions up to multiplet-orders of. The shape of these distributions is very similar to those shown for the strong 5 Cf source..6 Mixed-oxide powder The final sample was a mixed oxide (MOX) powder sample with a mass of 111.13g. The uranium has a natural enrichment, modelled with a density of.9 g/cm 3. The plutonium isotopic composition was.17% 38 Pu, 66.5% 39 Pu, 8.% Pu, 3.6% 1 Pu and.1% Pu with an Am/Pu ratio of.81. These isotopics were measured in December, 1988 [1]. The composition was corrected for radioactive decay between the source characterization date and the date of the experiment. This sample was modelled inside of a model-5 container placed at the bottom of the AWCC cavity. The model-5 container is another double walled stainless steel containers but with different dimensional ratios than the model- and 1. The MOX powder had a calculated activity of 73 n/s. x MOX Multiplicty Distribution 15 9 8 7 6 5 3 1 1 3 5 6 7 8 9 1 Figure 9, Comparison of the multiplicity distribution for the MOX sample The comparison of the R+A and A distributions for the MOX sample in Figure 9 show that the trends of the PERLA data are accurately captured by the MCNP-PoliMi simulation. However, there is a noticeable difference in the number counts for each multiplet bin. For the MOX, with an intermediate activity, there is a shift in the shape of the distributions from the lower-activity cases towards the parabolic shape that is characteristic of the more active sources. This shows that counting zero events after the trigger pulse is no longer the most probable.. CONCLUSIONS The post processor for the MCNP-PoliMi code has been enhanced to model multiplicity counting in a Canberra JCC-51 AWCC including the electronic deadtime and shift-register calculations. A total of six different samples were measured: low-intensity 5 Cf, high-intensity 5 Cf, Pu 9/1

E. C. Miller, S. D. Clarke, M. Flaska, et al. metal, small-volume PuO powder, large-volume PuO powder and mixed-oxide (MOX) powder. The results from MCNP-PoliMi have been compared to measured data for the passive multiplicity measurement of these samples. Very good agreement was observed for multiplets as high as order 5. ACKOWLEDGEMENT The initial MCNP model of the Canberra JCC-51 AWCC system was provided to us by Berit Dahl from Chalmers University of Technology. REFERENCES 1. R. Dierckx, and W. Hage. Neutron Signal Multiplet Analysis for the Mass Determination of Spontaneous Fission Isotopes, Nucl. Sci. Eng., 85, pp. 35-338 (1983).. M.S. Krick, and J.E. Swansen. Neutron and Multiplication Measurements, Nucl. Instr. and Meth., 19, pp. 38 393 (198). 3. P. Baeten, M. Bruggeman, R. Carchon and W. De Boeck. Neutron Measurements on 1 Waste Drums Containing Pu in the Range.1 1 g Pu eff with Time Interval Analysis Method, Nucl. Instr. and Meth. A, 13, pp. 333 3 (1998).. N. Ensslin, W.C. Harker, M.S. Krick, D.G. Langner, M.M. Pockrell and J.E. Stewart. Application Guide to Neutron Counting. Los Alamos National Laboratory, LA- 13-M. 5. M. Looman, P. Peerani, H. Tagziria. Monte Carlo simulation of neutron counters for safeguards applications Nucl. Instr. and Meth. A, 598, pp. 5-55 (9) 6. P. Peerani, H. Tagziria, M. Looman. Real-time simulation of neutron counters. Rad. Meas., 3, pp. 156-151 (8) 7. X-5 Monte Carlo Team. MCNP A General Monte Carlo N-Particle Transport Code, Version 5, vols. 1 3, Los Alamos National Laboratory, LA-UR-3-1987, LA-CP-3-5, and LA- CP-3-8 (3). 8. S. A. Pozzi, E. Padovani, and M. Marseguerra. MCNP-PoliMi: A Monte Carlo Code for Correlation Measurements, Nucl. Instr. and Meth. A, 513, pp. 55 558 (3). 9. S. A. Pozzi and K. Bekar, Analysis of Time Correlation Measurements with the Active Well Coincidence Counter, IAEA Symposium on International Safeguards: Addressing Verification Challenges, October 16, 6, Vienna, Austria. 1. S. Guardini, G. Guzzi, F. Mousty, S. Baumann, E. Kuhn, and P. de Regge. PERLA: Quality Control Provisions Applied in the Preparation and Characterization of Pu-Bearing Perla Standards. Report EUR 1338 EN, CEC-JRC Ispra (199). 1/1