E-STOP relays, safety gate monitors



Similar documents
E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PNOZsigma - Base units

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Contact expansion modules

Contact expander modules

E-STOP relays, safety gate monitors

PNOZ s3. Safety relays. Operating Manual EN-10

PNOZ s5. Safety relays. Operating Manual EN-09

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Safety technique. Emergency stop module BO 5988 safemaster

38 Series - Relay interface modules A

Safety automation solutions

38 Series - Relay interface modules A

mecotron Safety relay ESTOP-2 For emergency stop monitoring

CONFIGURABLE SAFETY RELAYS

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

HERZ-Thermal Actuators

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Quick Connect. quick - simple - efficient.

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04

MasterINTERFACE 39 Series - Relay interface modules

RM4TG20 three-phase network control relay RM4-T - range V

Safety Manual BT50(T) Safety relay / Expansion relay

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

MasterINTERFACE 39 Series - Relay interface modules

48 SERIES Relay interface modules 10 A

Relés e Contatores de Estado Sólido SIRIUS

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Electronic overload relay EF19 and EF45

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Preventa Machine Safety Products

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Safety Relays ESM/ESM-F

Electronic overload relay EF65, EF96 and EF146

Redundancy Module QUINT-DIODE/40

CONFIGURABLE SAFETY RELAYS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Units PSENmag. PSEN 2.2p Unit features. Function description

Type: DILM32 10(24V50HZ) Article No.:

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Three-phase monitoring relay CM-PFE

Product and functional description

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

SMS 4 / SMS 5 safety mat Product information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Thermistor motor protection

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

49 Series - Relay interface modules A. Features

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Pluggable interface relays CR-P Pcb relays

Thermal-Magnetic Circuit Breaker M1-..

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Preset Counter signo 721

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Type: DILM9 10(24VDC) Article No.:

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

NX safety stand-alone

RY2 miniature industrial relays

Digital input modules

Cross-beam scanning system to detect slim objects. 100 mm in

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Bimetallic Overload Relay Specifications

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Vario-Series Accessories

Transcription:

Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous 1 semiconductor output Connection options for: E-STOP pushbutton Safety gate limit switch Reset button Light barriers LED indicator for: Switch status channel 1/2 Supply voltage Semiconductor output signals: Switch status channel 1/2 Plug-in connection terminals (either spring-loaded terminal or screw terminal) See order reference for unit types Unit description ][Sicherheitseigenschaften Schaltgerät_allgemeiner Teil The relay meets the following safety requirements: The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. Zulassungen Bestimmung/Gertebeschreibung NOT-AUS, Schutzt, Lichtschr_PNOZ The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with E-STOP pushbuttons Safety gates Light beam devices Block diagram Blockschaltbild A1 A2 1 2 1 13 23 33 41 ~ = Input Input Input K1 Power 0 V 24 V Reset/ Start Reset/ Start Reset/ Start K2 Y30 Y31 Y32 3 4 5 6 3 4 14 24 34 42

Function description ][Funktionen_einkanalig Single-channel operation: no redundancy in the input circuit, earth faults in the reset and input circuit are detected. ][Funktionen_zweikanalig_mit_quer_ber Dual-channel operation with detection of shorts across contacts: redundant input circuit, detects earth faults in the reset and input circuit, Timing diagram short circuits in the input circuit and, with a monitored reset, in the reset circuit too, shorts between contacts in the input circuit. ][Funktionen_autoStart Automatic start: Unit is active once the input circuit has been closed. ][Funktionen_manuStart Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. ][Funktionen_berStart_Wartezeit Monitored reset: Unit is active once the input circuit is closed and once the reset circuit is closed after the waiting period has elapsed (see technical details). ][Funktionen_Kontaktvervielfachung Increase in the number of available instantaneous safety contacts by connecting contact expansion modules or external contactors. ][Zeitdiagram_auto_manu_ueber2_aux_semiCH 1 2 a b 3 POWER Reset/Start Input Output safe Output aux. Out semi CH t1 t2 t1 t2 t1 t2 t1 t2 t4 t1 t2 t4 t1 t2 t3 Key Power: Supply voltage Reset/Start: Reset circuit 3-4, 3-4 Input: Input circuits 1-2, -, 1- Output safe: Safety contacts 13-14, 23-24, 33-34 Output aux: Auxiliary contacts 41-42 Wiring ][Verdrahtung_Si_unverz_1Hi_unverz Please note: Information given in the Technical details must be followed. Outputs 13-14, 23-24, 33-34 are safety contacts, output 41-42 is an auxiliary contact (e.g. for display). To prevent contact welding, a fuse should be connected before the output contacts (see technical details). Calculation of the max. cable runs l max in the input circuit: Out semi CH: Semiconductor output switch status Y32 : Automatic reset : Manual reset : Monitored reset a: Input circuit closes before reset circuit b: Reset circuit closes before input circuit R lmax = max. overall cable resistance (see technical details) R l /km = cable resistance/km Use copper wire that can withstand 60/75 C. Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. t 1 : Switch-on delay t 2 : Delay-on de-energisation t 3 : Recovery time t 4 : Waiting period I max = R lmax R l / km -2

Preparing for operation Betriebsbereitschaft herstellen Supply voltage Supply voltage AC DC A1 L1 A1 L+ A2 N A2 L- Input circuit Input circuit Single-channel Dual-channel E-STOP without detection of shorts across contacts 2 1 1 1 2 E-STOP with detection of shorts across contacts 1 2 1 Safety gate without detection of shorts across contacts 2 1 1 1 2 S2 Safety gate with detection of shorts across contacts 1 S2 2 1 Light beam device with detection of shorts across contacts via ESPE 2 24 V DC

Reset circuit Reset circuit E-STOP wiring, safety gate Safety gate (dual-channel) Automatic reset 3 4 5 6 3 4 S2 Manual reset 3 4 Monitored reset 3 3 4 4 Feedback circuit Feedback circuit Automatic reset Monitored reset Contacts from external contactors 3 4 13 (23, 33) 14 (24, 34) K5 K6 K5 K6 L1 N 3 4 13 (23, 33) 14 (24,34) K5 K6 K5 K6 L1 N Semiconductor output Y31 Y32 Y30 24 V DC SPS Input 0 V Key /S2 E-STOP/safety gate switch Reset button Switch operated Gate open Gate closed -4

Terminal configuration Klemenbelegung A1A 1 1 13 X1 P3 1 2 3 4 X2 P4 23 33 41 POWER CH.1 CH.2 13 23 33 41 14 24 34 42 18995 A2 A X3 P3 2 6 5 3 4 X4 P4 Y30 Y31 Y32 14 24 34 42 Installation Montage_PNOZ_X The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). Dimensions Abmessungen * with spring-loaded terminals 121 (4.76") 94 (3.70") * 101 (3.98") 45 (1.77")

Notice ][WICHTIG_PDB_alt This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit. Service life graph D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 AC15: 230 V DC13: 24 V Lebensdauerkurve DC1: 24 V AC1: 230 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 E Número de ciclos x 10 3 GB Cycles x 10 3 I Numero dei cicli di commutazione x 10 3 F Nombre de manœuvres x 10 3 NL Aantal schakelingen x 10 3 ][Technische Daten PNOZ Technical details Electrical data Supply voltage Supply voltage U B AC/DC 24 V Voltage tolerance -15 %/+10 % Power consumption at U B AC 5.0 VA Power consumption at U B DC 2.5 W Frequency range AC 50-60 Hz Residual ripple DC 160 % Voltage and current at Input circuit DC: 24.0 V 40.0 ma Reset circuit DC: 24.0 V 70.0 ma Feedback loop DC: 24.0 V 20.0 ma Number of output contacts Safety contacts (S) instantaneous: 3 Auxiliary contacts (N/C): 1 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V I min : 0.01 A, I max : 8.0 A P max : 2000 VA Safety contacts: DC1 at 24 V I min : 0.01 A, I max : 8.0 A P max : 200 W Auxiliary contacts: AC1 at 240 V I min : 0.01 A, I max : 8.0 A P max : 2000 VA Auxiliary contacts: DC1 at 24 V I min : 0.01 A, I max : 8.0 A P max : 200 W Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I max : 5.0 A Safety contacts: DC13 at 24 V (6 cycles/min) I max : 6.0 A Auxiliary contacts: AC15 at 230 V I max : 5.0 A Auxiliary contacts: DC13 at 24 V (6 cycles/min) I max : 6.0 A Contact material AgSnO2 + 0.2 µm Au -6

Electrical data External contact fuse protection (I K = 1 ka) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 10 A Auxiliary contacts: 10 A Blow-out fuse, slow Safety contacts: 6 A Auxiliary contacts: 6 A Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: 6 A Auxiliary contacts: 6 A Semiconductor outputs (short circuit proof) 24.0 V DC,20 ma External supply voltage 24.0 V DC Voltage tolerance -20 %/+20 % Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC 150 Ohm single-channel at U B AC 180 Ohm dual-channel without detect. of shorts across contacts at U B DC 300 Ohm dual-channel without detect. of shorts across contacts at U B AC 360 Ohm dual-channel with detect. of shorts across contacts at U B DC 15 Ohm dual-channel with detect. of shorts across contacts at U B AC 30 Ohm Safety-related characteristic data PL in accordance with EN ISO 13849-1 PL e (Cat. 4) Category in accordance with EN 954-1 Cat. 4 SIL CL in accordance with EN IEC 62061 SIL CL 3 PFH in accordance with EN IEC 62061 2.31E-09 SIL in accordance with IEC 61511 SIL 3 PFD in accordance with IEC 61511 2.03E-06 t M in years 20 Times Switch-on delay with automatic reset typ. 250 ms with automatic reset max. 500 ms with automatic reset after power on typ. 280 ms with automatic reset after power on max. 550 ms with manual reset typ. 200 ms with manual reset max. 500 ms on monitored reset with rising edge typ. 35 ms on monitored reset with rising edge max. 50 ms Delay-on de-energisation with E-STOP typ. 15 ms with E-STOP max. 30 ms with power failure typ. 180 ms with power failure max. 260 ms Recovery time at max. switching frequency 1/s after E-STOP 50 ms after power failure 350 ms Waiting period with a monitored reset with rising edge 300 ms Min. start pulse duration with a monitored reset with rising edge 30 ms Simultaneity, channel 1 and 2 Supply interruption before de-energisation 150 ms

Environmental data EMC EN 60947-5-1, EN 61000-6-2 Vibration to EN 60068-2-6 Frequency 10-55 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78 Airgap creepage in accordance with EN 60947-1 Pollution degree 2 Overvoltage category III Rated insulation voltage 250 V Rated impulse withstand voltage 4.0 kv Ambient temperature -20-55 C Storage temperature -40-85 C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20 Mechanical data Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0 Cross section of external conductors with screw terminals 1 core flexible 0.25-2.50 mm², 24-12 AWG Order no.: 777314 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.25-1.00 mm², 24-16 AWG Order no.: 777314 without crimp connectors or with TWIN crimp connectors 0.20-1.50 mm², 24-16 AWG Order no.: 777314 Torque setting with screw terminals 0.50 Nm Order no.: 777314 Cross section of external conductors with spring-loaded terminals: 0.20-1.50 mm², 24-16 AWG Order no.: 787314 Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection 2 Order no.: 787314 Stripping length 8 mm Order no.: 787314 Dimensions Height 101.0 mm Order no.: 787314 94.0 mm Order no.: 777314 Width 45.0 mm Depth 121.0 mm Weight 270 g Order no.: 787314 280 g Order no.: 777314 Technische Daten_Satz Normen The standards current on 2007-09 apply. ][Dauerstrom_ACDC Conventional thermal current Number of contacts I th (A) at U B DC I th (A) at U B AC 1 8.00 A 8.00 A 2 8.00 A 7.00 A 3 7.00 A 6.00 A Bestelldaten Order reference Type Features Terminals Order no. C 24 VAC/DC Spring-loaded terminals 787 314 24 VAC/DC Screw terminals 777 314-8