aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

Similar documents
aurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

WATERS QUANTITATIVE ANALYSIS solutions

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

NUVISAN Pharma Services

LC-MS/MS for Chromatographers

NexION 350 ICP-MS Maximum throughput. Minimum downtime. Optimum insight.

SCION SQ Series GC-MS

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

High Sensitivity ICP-MS: Overcome the problem of complex samples

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Specifications. MassHunter WorkStation for Agilent 7700 Series ICP-MS. Specifications: MassHunter Workstation (G7211A) for the Agilent 7700 Series

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Elemental Scientific. Stability. Elemental Scientific

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Pesticide Analysis by Mass Spectrometry

Guidance for Industry

Sample Analysis Design Isotope Dilution

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Mass spectrometry. What are the principles behind MS? What do all MS instruments have in common?

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Appendix 5 Overview of requirements in English

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

8. SUMMARY AND CONCLUSION

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

2016 Edition United States and Canada AGILENT UNIVERSITY COURSE CATALOG

Elemental Analyses by ICP-AES

C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to

Sample Analysis Design Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors:

Application of ICP-MS and LC-ICP-MS in Drug Development Jaap Wieling. EBF Focus Meeting, Brussels

DMA-1 Direct Mercury Analyzer

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

World Leader in MALDI-QIT-TOF MS Technology

AMD Analysis & Technology AG

Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis

The 30-Minute Guide to ICP-MS

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Volume 22 Number 22. C43-A ISBN ISSN Gas Chromatography/Mass Spectrometry (GC/MS) Confirmation of Drugs; Approved Guideline

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

The Sievers 900 Series TOC Analyzers

Mass Spectrometry Signal Calibration for Protein Quantitation

How To Build An Amd Quas 3 Ar Mass Spectrometer

Thermo Scientific ConFlo IV Universal Interface

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

Waters Core Chromatography Training (2 Days)

How To Test For Contamination In Large Volume Water

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

6. ANALYTICAL METHODS

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

MILESTONE H E L P I N G C H E M I S T S

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

AssurX Makes Quality & Compliance a Given Not Just a Goal

A commitment to quality and continuous improvement

Analytical Methods for Cleaning Validation

Factors Influencing LC/MS/MS Moving into Clinical and Research Laboratories

Thermo Scientific Qtegra Intelligent Scientific Data Solution Software. Delivering quality. Driving productivity

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Regional Environmental Protection Agency- Veneto Region LABORATORY REGIONAL DEPARTMENT

consultancy services

Finnigan ELEMENT2. High Performance High Resolution ICP-MS

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Samples RMN Analytical Report ( ) GC/FID Analysis (RM01) Nicotine Purity

Matrix Gemini Laboratory Information Management. Delivering Configurable Future-Proof Solutions

DO MORE AND DO IT WITH CONFIDENCE. Empower 3 Chromatography Data Software

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

LC-MSMS - state of the art in endocrinology

Analyzing Small Molecules by EI and GC-MS. July 2014

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

Transcription:

aurora ICP-MS The Science of Sensitivity Innovation with Integrity ICP-MS

Powers the Business of Quantification aurora ICP-MS enhanced value package Bruker s ICP-MS is famous for its innovative and unique technology and has now been further refined to meet the ever increasing demands of latest application and laboratory requirements. aurora s plasma system with patented turner-interlaced coils for an exceptional robust plasma and the lowest oxide ratios Key Benefits Bruker s ICP-MS team is continuously working on product improvements to reflect the requirements of today s analytical tasks and challenges. The following features are available for aurora M90 and aurora Elite: Lowest cost of ownership: rugged design, durable cone system, no expensive spare parts, and a unique all-digital detector with a typical lifetime of more than 5 years. 21 CFR Part 11 compliance support for Quantum ICP-MS software: to meet the requirements of the pharmaceutical industry aurora s Quantum software and CompassCDS offers new features such as audit trails, electronic signatures and user management. External Device Control: bidirectional triggering for seamless connectivity to laser ablation and chromatographic devices. Improved air flow management inside the instrument: with significantly reduced exhaust flow requirements which diminishes installation cost and is of particular interest in clean room environments.

The Science of Sensitivity The Power of Sensitivity Sensitivity is a must when low detection limits are the goal; it is the enabler to overcome a wide range of challenges in ICP-MS analysis and its applications. Precise and accurate quantification at single digit ppt concentration levels - for semiconductor, geochemistry, materials science and related applications in standard as well as in interference management mode. Enables the use of shorter integration times without deteriorating precision: for shorter measurements and consequently higher sample throughput. Higher dilution factors without sacrificing detection limits: for complex matrix samples which results in less matrix effects, less cone depositions, minimized drifts and reduced washout times. Higher sensitivity in interference management mode (Helium/Hydrogen mode) for improved detection limits of spectrally interfered isotopes and highest accuracy. When coupled to laser ablation devices aurora Elite s unmatched Gigahertz sensitivity allows the use of lower laser energy for the analysis of smaller spot-sizes and improved spatial resolution. Ideal for applications in geochemisty and materials sciences. The combination of aurora Elite s high sensitivity with its all-digital detector delivers excellent results for isotope ratio determinations of low concentrations and/or large ratios, certainly in liquids and solids. The combination of aurora Elite s Gigahertz sensitivity and the possibility of ultrashort integration times makes aurora the ideal instrument for the analysis of nanoparticles and discovers them at the smallest dimensions.

Quantum and Compass CDS Software 21 CFR Part 11 Compliance Support for Quantum ICP-MS Software 21 CFR Part 11 requires drug and medical device manufacturers, biotechnology companies, biologics developers, CRO s, and other FDA-regulated industries, with some specific exceptions, to implement controls, including audits, system validations, audit trails, electronic signatures, and documentation for software and systems involved in processing electronic data that are: (a) required to be maintained by the FDA predicate rules; or (b) used to demonstrate compliance to a predicate rule. The Quantum Configuration Manager controls: User access control User permissions Audit logging Data security Within Quantum Restricted items are greyed-out User rights profiles enable restriction of >100 user actions Mandatory Reason and Comment fields are active Worksheet audit logs record all changes

The Science of Sensitivity Bruker continues the innovation of ICP-MS Bruker s aurora M90 remains the workhorse for the routine laboratory, now with additional features and Intact improved protein characteristics. mass resolution In addition to the aurora M90, Bruker now offers a second model, the aurora Elite, the new high-end performance offering in Bruker s ICP-MS range, setting new and exceptional standards for sensitivity and matrix robustness in ICP-MS. New Features Performance characteristics and new features for the aurora M90 and the new aurora Elite now include: 1.5 GHz / ppm: aurora Elite is by far the most sensitive ICP-MS available needless to say with lowest background, and of course with conventional or low flow nebulizer. Lowest oxide ratios: using turner-interlaced coils which ensure robust plasma conditions for complete matrix decomposition all without the requirement for a plasma shield or guard electrode. 100 μs integration times: combining sensitivity, scan speed and integration time to an unmatched performance combination across the entire industry. Easy-to-use interference management: using the established Collision Reaction Interface (CRI II) simple, robust, maintenance free Helium or Hydrogen prepared for all interference challenges without any additional effort.

Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. BDAL 01-2013, 1815831 Science of Sensitivity Powers the Business of Quantitation SCION GC Bruker s new SCION GC platform provides the ultimate capability for today s analytical laboratory. Available in two models: the space-saving SCION 436-GC and the full-featured SCION 456-GC. New features designed to enhance productivity, robustness, and ease-of-use. The platform offers more than 50 custom configurations supporting a wide range of applications including our GC Analyzer solutions packages. SCION GC-MS Bruker SCION Series GC-MS instruments provide outstanding performance in space concious platform. The SCION Series is available with singe quadrupole or triple quadrupole mass analyzers. Either system can be equipped with the latest GC technology, the SCION 436 or SCION 456 gas chromatograph. Bruker s long traditions of innovation and product reliability have combined to create a new industry standard for gas chromatography single quadrupole mass detection the SCION SQ. EVOQ The EVOQ triple quadrupole for liquid chromatography (LC-TQ) was designed for a singular purpose to reliably quantify thousands of real samples in the fastest sample-to-report time possible. It delivers exceptional sensitivity, precision, accuracy, linearity, and a wide dynamic range for your multiple reaction monitoring (MRM) assays. Innovations in software and atmospheric pressure ionization (API) technology make it a game changer for routine high-sensitivity, quantitative analysis. For research use only. Not for use in diagnostic procedures. Bruker Daltonik GmbH Bremen Germany Phone +49 (0)421-2205-0 Fax +49 (0)421-2205-103 sales@bdal.de Bruker Daltonics Inc. Billerica, MA USA Fremont, CA USA Phone +1 (978) 663-3660 Phone +1 (510) 683-4300 Fax +1 (978) 667-5993 Fax +1 (510) 490-6586 ms-sales@bdal.com ms-sales@bdal.com www.bruker.com