Data Center CH1 Elk Grove Village, IL
powerful/ efficient /reliable solutions >
Data Center CH1 ABOUT DUPONT FABROS TECHOLOGY (DFT) DFT is a leading owner, developer, operator and manager of wholesale data centers. Our highly advanced and secure facilities power, cool, and protect the computer servers of numerous enterprise and technology companies. In conjunction with our operational expertise, we deliver uninterrupted service and ultimate reliability to our customers mission critical business applications. OVERVIEW Located in the western suburbs of Chicago, CH1 is one of the Midwest s most sophisticated and efficient data centers. The facility is constructed in two phases of 18.2 MW of Critical Load each. Clients are able to lease one or multiple dedicated computer rooms each with independent redundancy and security. The property has multiple major fiber carriers on site and benefits from some of the country s most competitive power rates. Customers requiring substantial office space can utilize the adjacent and exclusive 32,000 square foot office building. PHILOSOPHY Committed to ultimate reliability, DFT s philosophy is to design, build, operate and manage highly dependable and environmentally efficient data centers. Our goal is to maximize Power Usage Effectiveness ("PUE") in all aspects of data center operations. Dynamic electrical distribution and flexible floor plans provide optimal solutions for our tenants. DFT commissions proven technologies, such as rotary UPS and evaporative chilled water systems, in configurations that maximize utilization of the data center design and infrastructure. Our engineering track record and expertise enable us to shorten the duration of construction and minimize costs which directly benefit our clients. >
Data Center CH1: Specifications Location: Elk Grove Village, IL Acreage: 22.8 Building Size: 485,000 sq ft Nearest Airport: O'Hare International Airport PROPERTY BUILDING DESCRIPTION COMPUTER ROOM SPECIFICATIONS DATA CENTER AREA DESCRIPTION STAGING/TENANT OFFICE SPACE SECURITY CRITICAL POWER UPS SYSTEMS GENERATORS ON SITE FUEL CAPACITY HEAT REJECTION SYSTEMS (HVAC) STS/PDUS COMMUNICATIONS Utility Power: 34.5 kv Parking: 400+ Number of Stories: 1 Loading Docks: 4 Dock Bays Phase 1: Critical Load: 18.2 MW Rooms 1-3: Critical Load: 0.433 MW, Approx. Gross SF: 2,700 Rooms 4-13: Critical Load: 1.3 MW, Approx. Gross SF: 8,400 Rooms 14-16: Critical Load: 1.3 MW, Approx. Gross SF: 9,900 Phase 2: Critical Load: 18.2 MW Rooms 18A-18B: Critical Load: 0.650 MW, Approx. Gross SF: 5,000 Rooms 17, 19-26: Critical Load: 1.3 MW, Approx. Gross SF: 7,300-8,900 Rooms 27A & 27B, 28A & 28B: Critical Load 2.6 MW, Approx. Gross SF: 13,900-14,300 Raised Floor Area: 121,000 sq ft (Phase I), 109,666 sq ft (Phase II) Number of Computer Rooms: 16 (Phase I), 15 (Phase II) Raised Floor Height: 42" under raised floor plenums Raised Floor to Ceiling Height: 15-20+ft Office: 9 internal suites and 32,000 sf of adjacent office space Staging: 6 staging rooms (Phase I), 2 staging rooms (Phase II) Building and Perimeter: Ballistic glass enclosed security check-in, front window areas and loading dock Security Guards: Staffed 24/7 Access Control: Electronic Security features with card key access and dual authentication with biometric readers CCTV: 24/7 surveillance of the interior/exterior of the facility Total Megawatts: 36.4 Redundancy: N+2, Each Phase, plus additional Swing UPS which offers additional redundancy to either electrical system Description: 32 Rotary power systems with 1,300 kw of critical output each Redundancy: N+2, Each Phase Description: 32 diesel-powered engine generators with 2,250 kw capacity each Redundancy: N+2, Each Phase Storage Tanks: Four 50,000 gallon underground diesel storage tanks Number of Hours: Nominal 55 Hours Description: 16 centrifugal chillers with 1,150 Ton capacity each Redundancy: N+2, Each Phase Chilled Water Storage: Two 500,000 gallon storage tanks for 24 minutes of continuous full load operation STS Description: Dual input Static Transfer Switches (STSs) PDU Description: 300 kva Power Distribution Units (PDUs) : 4 separate network Points of Entry () with diverse underground duct banks providing multiple entry points into the facility Conduits: Dedicated underground conduits to each computer room from multiple and diverse s Multiple Carriers: Available Meet-Me-Room: Available Description: Conventional smoke detector and laser based incipient smoke detection systems and double interlocked pre-action sprinkler system FIRE PROTECTION >
Data Center CH1: Map CENTRIFUGAL CHILLER (TYP.) BR. RM. BR. RM. MECH. RM. MECH. RM. MECH. RM. LOB. LOADING DOCK W. 17 OFFICE CORRIDOR MMR OFFICE SEC EQ MMR X X 22 21 20 19 18A 4 8 COMPUTER ROOMS 17-28 COMPUTER ROOMS 1-16 26 25 24 23 18B 10 11 12 13 CORRIDOR 28B 28A 27B 27A 14 15 16 CORRIDOR TRANSFORMER STOR. SNOW MELT AREAWAY AREAWAY STOR. FP/PL RM. STOR. SWITCHBOARD (TYP.) UPS UNIT AREAWAY (TYP.) PHASE 2 PHASE 1 AREAWAY DIESEL ENGINE GENERATOR (TYP.) SPACE ALLOCATIONS Electrical/Mechanical Computer Room Public Circulation Data/Telco Support Administration/Office BR. RM. MECH. RM. MECH. RM. W. ELEV. TELE/COMM ELEV. BR. RM. LOB. W. SECOND FLOOR CON. FIRST FLOOR M. 1 2 3 19 5 6 7 M. M.
For more information please contact leasing@dft.com 1212 New York Ave., NW Suite 900 Washington, DC 20005 P 202.728.0044 F 202.728.0220 www.dft.com NYSE: DFT