Data Center CH1. Elk Grove Village, IL



Similar documents
Experience Matters...

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

AT&T Internet Data Center Site Specification Washington-DC Area (Ashburn, VA)

Santa Clara, CA 95054

san francisco//usa data center specifications tel: fax: internet + intellectual property + intelligence

Chicago 1 (CHI-1) Data Center

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

Digital Chicago. 600 south FeDeraL - chicago grand ave - FranKLin ParK 350 east cermak - chicago

COMMODITIZING THE DATA CENTER MARKET

How To Visit An Internet Data Center

LEVEL 3 DATA CENTER SERVICES IN OMAHA, NEBRASKA HIGH AVAILABILITY ENTERPRISE COMPUTING BUSINESS DEMANDS IT. LEVEL 3 DELIVERS IT.

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

Data Center Planning. PUE Overview

1301 Fannin. Houston Data Center & Office Facility

AT&T Internet Data Center Site Specification New York III (Secaucus, NJ)

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

OPERATOR - FACILITY ADDRESS - DATE

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

NY2 21 CRITICAL MEGAWATTS 280,000 SQUARE FEET

LEVEL 3 DATA CENTER SERVICES IN SAN FRANCISCO HOUSE POWER-INTENSIVE APPLICATIONS AND SUPPORT BUSINESS CONTINUITY

AT&T Internet Data Center Site Specification San Diego Koll (San Diego, CA)

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Strategic Data Centre Site Profiles Data Centre Co-Location London North

Secure I Reliable I Flexible COPT DC Hornbaker Road, Manassas, Virginia

Data Centre Barrie, Ontario

colocation. perfected. Overview

19 Site Location, Design and Attributes. Site Location, Design and Attributes

N O W A V A I L A B L E

AT&T Internet Data Center Site Specification Dallas Area (Allen, Tx)

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

FOR LEASE. 823 Pilot Rd. - Data Center. Las Vegas, NV. Property Features:

Global Data Center & Colocation Facilities

Data Center Infrastructure & Managed Services Outline

Subject: County of Los Angeles Data Center Space Requirement

Assessment of Existing Data Centers for Critical Facilities Round Table Group

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

GREEN DATA CENTER DESIGN

How To Build A Data Center For Ragingwire

Data Centre Basiglio, Milan Flexible, advanced and efficient by design.

Wholesale Data Center Suites Available Now

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Data Center Colocation Build vs. Buy

Iron Hill Corporate Center Newark, DE

Total Cost of Ownership Analysis for Data Center Projects

Scalable. Affordable. Flexible. Fast.

CyrusOne Global Data Center Solutions

Pacnet Hong Kong CloudSpace2 Technical Specifications. Upholding the Principles of Efficiency and Sustainability in Data Center Design

Department of the Interior

Why Choose Go4Hosting Data Center?

Presentations, One Summer Street UPS/ Generator Power and Boston Data Center Facility Overview. GridSolar, LLC

X-tier Data Facility. Prepared by X-tier SAE Corporation

Technical specifications. Containerized data centre NTR CDC 40f+

POWERING A CONNECTED ASIA. Pacnet Hong Kong CloudSpace1 Technical Specifications. Asia s Pioneering Facility with Direct Subsea Cable Access

Data Center:Build-to-Suit

NEW JERSEY CENTER OF EXCELLENCE

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Seattle London

Global Data Center Solutions

Data Centre Powergate, London Flexible, advanced and efficient by design.

vcloud SERVICE Virtual Tech in partnership with Equinix - vcloud Service

NY-1 DATACENTER AT A GLANCE. NY-1 is a Tier III-rated, SAS SSAE16 and HIPAA-certified data center

ISOMEDIA COLOCATION

DATA CENTERS. POWERED BY TRUST DuPONT FABROS TECHNOLOGY

Strategic Data Centre Site Profiles. Data Centre Co-Location London East

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group

Onsite Support: 24/7/365 onsite team. Security: 24/7/365 onsite manned security and CCTV. Monitoring: 24/7/365 Environmental monitoring and management

BRUNS-PAK Presents MARK S. EVANKO, Principal

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

Data Center Components Overview

Data Center Presentation

Energy Efficient High-tech Buildings

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

Data Centre Southeast AMS 5, Netherlands Highly connected, premium data centre.

Green Data Centre Design

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

House your data in a building constructed for only one express purpose protect the information inside. Twin Cities East Data

Relevant Mission Critical Experience

AFS Center. Data Center Info. Arizona Facility Services 2331 West Alameda Dr Tempe, AZ (602) Main (602) Fax

Colocation. Introduction. Structure of the service. Service Description

Electrical Systems. <Presenter>

DATACENTER COLOCATION. Flexible, Secure and Connected

PHP/MySQL APPLicAtion HoSting

Data Centre Infrastructure

National Aluminium Co. Ltd.

LDeX Group. Colocation Solutions for High Expectations

VOLICO. Colocation Hosting. Enterprise Hosting Solutions

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Transcription:

Data Center CH1 Elk Grove Village, IL

powerful/ efficient /reliable solutions >

Data Center CH1 ABOUT DUPONT FABROS TECHOLOGY (DFT) DFT is a leading owner, developer, operator and manager of wholesale data centers. Our highly advanced and secure facilities power, cool, and protect the computer servers of numerous enterprise and technology companies. In conjunction with our operational expertise, we deliver uninterrupted service and ultimate reliability to our customers mission critical business applications. OVERVIEW Located in the western suburbs of Chicago, CH1 is one of the Midwest s most sophisticated and efficient data centers. The facility is constructed in two phases of 18.2 MW of Critical Load each. Clients are able to lease one or multiple dedicated computer rooms each with independent redundancy and security. The property has multiple major fiber carriers on site and benefits from some of the country s most competitive power rates. Customers requiring substantial office space can utilize the adjacent and exclusive 32,000 square foot office building. PHILOSOPHY Committed to ultimate reliability, DFT s philosophy is to design, build, operate and manage highly dependable and environmentally efficient data centers. Our goal is to maximize Power Usage Effectiveness ("PUE") in all aspects of data center operations. Dynamic electrical distribution and flexible floor plans provide optimal solutions for our tenants. DFT commissions proven technologies, such as rotary UPS and evaporative chilled water systems, in configurations that maximize utilization of the data center design and infrastructure. Our engineering track record and expertise enable us to shorten the duration of construction and minimize costs which directly benefit our clients. >

Data Center CH1: Specifications Location: Elk Grove Village, IL Acreage: 22.8 Building Size: 485,000 sq ft Nearest Airport: O'Hare International Airport PROPERTY BUILDING DESCRIPTION COMPUTER ROOM SPECIFICATIONS DATA CENTER AREA DESCRIPTION STAGING/TENANT OFFICE SPACE SECURITY CRITICAL POWER UPS SYSTEMS GENERATORS ON SITE FUEL CAPACITY HEAT REJECTION SYSTEMS (HVAC) STS/PDUS COMMUNICATIONS Utility Power: 34.5 kv Parking: 400+ Number of Stories: 1 Loading Docks: 4 Dock Bays Phase 1: Critical Load: 18.2 MW Rooms 1-3: Critical Load: 0.433 MW, Approx. Gross SF: 2,700 Rooms 4-13: Critical Load: 1.3 MW, Approx. Gross SF: 8,400 Rooms 14-16: Critical Load: 1.3 MW, Approx. Gross SF: 9,900 Phase 2: Critical Load: 18.2 MW Rooms 18A-18B: Critical Load: 0.650 MW, Approx. Gross SF: 5,000 Rooms 17, 19-26: Critical Load: 1.3 MW, Approx. Gross SF: 7,300-8,900 Rooms 27A & 27B, 28A & 28B: Critical Load 2.6 MW, Approx. Gross SF: 13,900-14,300 Raised Floor Area: 121,000 sq ft (Phase I), 109,666 sq ft (Phase II) Number of Computer Rooms: 16 (Phase I), 15 (Phase II) Raised Floor Height: 42" under raised floor plenums Raised Floor to Ceiling Height: 15-20+ft Office: 9 internal suites and 32,000 sf of adjacent office space Staging: 6 staging rooms (Phase I), 2 staging rooms (Phase II) Building and Perimeter: Ballistic glass enclosed security check-in, front window areas and loading dock Security Guards: Staffed 24/7 Access Control: Electronic Security features with card key access and dual authentication with biometric readers CCTV: 24/7 surveillance of the interior/exterior of the facility Total Megawatts: 36.4 Redundancy: N+2, Each Phase, plus additional Swing UPS which offers additional redundancy to either electrical system Description: 32 Rotary power systems with 1,300 kw of critical output each Redundancy: N+2, Each Phase Description: 32 diesel-powered engine generators with 2,250 kw capacity each Redundancy: N+2, Each Phase Storage Tanks: Four 50,000 gallon underground diesel storage tanks Number of Hours: Nominal 55 Hours Description: 16 centrifugal chillers with 1,150 Ton capacity each Redundancy: N+2, Each Phase Chilled Water Storage: Two 500,000 gallon storage tanks for 24 minutes of continuous full load operation STS Description: Dual input Static Transfer Switches (STSs) PDU Description: 300 kva Power Distribution Units (PDUs) : 4 separate network Points of Entry () with diverse underground duct banks providing multiple entry points into the facility Conduits: Dedicated underground conduits to each computer room from multiple and diverse s Multiple Carriers: Available Meet-Me-Room: Available Description: Conventional smoke detector and laser based incipient smoke detection systems and double interlocked pre-action sprinkler system FIRE PROTECTION >

Data Center CH1: Map CENTRIFUGAL CHILLER (TYP.) BR. RM. BR. RM. MECH. RM. MECH. RM. MECH. RM. LOB. LOADING DOCK W. 17 OFFICE CORRIDOR MMR OFFICE SEC EQ MMR X X 22 21 20 19 18A 4 8 COMPUTER ROOMS 17-28 COMPUTER ROOMS 1-16 26 25 24 23 18B 10 11 12 13 CORRIDOR 28B 28A 27B 27A 14 15 16 CORRIDOR TRANSFORMER STOR. SNOW MELT AREAWAY AREAWAY STOR. FP/PL RM. STOR. SWITCHBOARD (TYP.) UPS UNIT AREAWAY (TYP.) PHASE 2 PHASE 1 AREAWAY DIESEL ENGINE GENERATOR (TYP.) SPACE ALLOCATIONS Electrical/Mechanical Computer Room Public Circulation Data/Telco Support Administration/Office BR. RM. MECH. RM. MECH. RM. W. ELEV. TELE/COMM ELEV. BR. RM. LOB. W. SECOND FLOOR CON. FIRST FLOOR M. 1 2 3 19 5 6 7 M. M.

For more information please contact leasing@dft.com 1212 New York Ave., NW Suite 900 Washington, DC 20005 P 202.728.0044 F 202.728.0220 www.dft.com NYSE: DFT