PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative



Similar documents
An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Gas Separations: A Comparison of GasPro and Aluminum Oxide PLOT Columns for the Separation of Highly Volatile Compounds

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

BTU ANALYSIS USING A GAS CHROMATOGRAPH

23 The Thermal Conductivity Detector

Get the Right GC for Your Industry

Pilot Gasifier Producer Gas Analysis and Measurement Arrangements in. University of Applied Sciences

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Hands-on Workshop on Advanced Hydrocarbon Analysis July 23, 2015

Addressing the World Helium Shortage For Gas Chromatography

How To Run A Gas Plant

Diffusion and Fluid Flow

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

Gas Chromatography Liner Selection Guide

Chromatograph Maintenance and Troubleshooting Class # 5050

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

Transformer Oil Gas Analysis

SUCRALOSE. White to off-white, practically odourless crystalline powder

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Question Bank Organic Chemistry-I

ß-CYCLODEXTRIN SYNONYMS

Page Which hydrocarbon is a member of the alkane series? (1) 1. Which is the structural formula of methane? (1) (2) (2) (3) (3) (4) (4)

On-line Ozone Precursor Analyzers From the Leader in Thermal Desorption Technology

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Molecular Sieve Adsorbents

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Process Instrumentation

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

Fractional Distillation and Gas Chromatography

On-line Dissolved Gas Analysis

Background Information

DOWEX Resins as Organic Solvent Desiccants

UOP Adsorbents COMPREHENSIVE PORTFOLIO TO REMOVE CONTAMINANTS FROM A VARIETY OF SOURCES. UOP Adsorbent Solutions

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

RECITATION NOTES FOR EXPERIMENT # 5 A&B THIN LAYER CHROMATOGRAPHY

Thermal Conductivity Detector

MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

Theory and Instrumentation of GC Introduction

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION ACKNOWLEDGEMENT ABSTRACT LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS LIST OF APPENDICES

The photoionization detector (PID) utilizes ultraviolet

Fluid & Gas Properties

AN INTRODUCTION TO HEADSPACE SAMPLING IN GAS CHROMATOGRAPHY FUNDAMENTALS AND THEORY. Andrew Tipler

Natural Gas Processing Solutions Using the 700XA Gas Chromatograph

CHROMOCTANE O N LINE ANALYZER

Expectations for GC-MS Lab

Purification of reaction mixtures using flash chromatography.

Fundamentals of Gas Chromatography

Analyzing Small Molecules by EI and GC-MS. July 2014

Evolution of Ozone Precursor Measuring and the PAMs Project from 1992 to Present

For Chromatography, you must remember Polar Dissolves More, not like dissolves like.

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Alkanes. Chapter 1.1

AMD Analysis & Technology AG

NGL RECOVERY PLANT: TREATER OPTIMIZATION FOR WATER AND MERCAPTAN REMOVAL

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

EXPERIMENT 1 - Determination of the purity and identity of organic compounds by melting point and/or analytical thin layer chromatography

Analysis of Liquid Samples on the Agilent GC-MS

Gas Chromatography. Gas Chromatograph

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

SYLOBEAD Adsorbents. for Natural Gas Processing. Introduction. Therefore, it is often necessary to condition the raw gas to:

Micro Cryo-Trap Model 971

Petrochemical Industry Ethylene Plant

Balancing chemical reaction equations (stoichiometry)

Dionex IonPac AS19-4µm

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Operating Hints for Using Split/Splitless Injectors

Agilent 7697A Headspace Sampler Data Sheet

Thermo Scientific ConFlo IV Universal Interface

DGA - Method in the Past and for the Future

Mass Spectrometry. Fundamental GC-MS. GC Considerations

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Split / Splitless Injection for Capillary GC

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Question (3): What are the different types of covalent bonds found in carbons compounds? Briefly explain with examples.

Separation of Amino Acids by Paper Chromatography

C184-E014D GC Shimadzu Gas Chromatograph System

Bulletin 864A. Simulated Distillation of Petroleum Products by Packed Column and Capillary Column GC

FOR RISK ASSESSMENT. Analysis of mineral oil: Manual pre-separation, followed by LV-GC/FID Off-line HPLC-GC/FID FEDERAL INSTITUTE.

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Clarus 580 Gas Chromatograph

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Gas Chromatograph GC Consumables. p/n:

Lecture Overview. Hydrogen Bonds. Special Properties of Water Molecules. Universal Solvent. ph Scale Illustrated. special properties of water

Lecture 35: Atmosphere in Furnaces

EXTENDING MOLECULAR SIEVE LIFE IN NATURAL GAS DEHYDRATION UNITS

SCION GC Series. Innovation with Integrity. The Gas Chromatographers Choice for Separations GAS CHROMATOGRAPHY

Oasis HLB Cartridges and 96-Well Plates

Transcription:

PLOT Columns Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

PLOT Column Selection 93 Features & Benefits of Restek PLOT Columns Features Highest quality porous materials. Benefits The most consistent and efficient analyses obtainable. Consistency in porosity and uniformity in particle and pore size are major concerns in designing the solid stationary phase. We developed a unique synthesis and selection technology to yield uniform, small diameter particles that are ideal for a specific separation. Particles are 100% bonded to the tubing. No need for particle traps because particle generation is eliminated. Restek coating and bonding techniques produce strong, uniform particle adherence to the inside of the capillary tubing. Customers have described Restek s Rt -Msieve 5A PLOT column as bulletproof, meaning that the stationary phase is bonded so strongly that particle generation is completely eliminated. Reproducible quality. Reproducible performance. Because we use advanced technology to make these columns, the entire manufacturing process is simple and stable. Each step of the column-making process is meticulously quality-checked, allowing Restek to offer the best quality PLOT columns. Quick Reference Chart PLOT Column Rt -Alumina Rt -Msieve 5A Rt -QPLOT Rt -QSPLOT Application C1 C5 hydrocarbons. purity analysis of ethylene, propylene, butenes, butadiene................................. 94 95 Permanent gas analysis. He, Ne, Ar, O2, N2, Xe, Rn, SF6, and CH4, C2H6, Co............................................ 96 Nonpolar porous polymer. High retention for volatiles, CO2, sulfur, and ppm water in solvents..............................97 Intermediate polarity porous polymer. Baseline separation of ethane, ethene, acetylene............................................ 97 Page Rt -SPLOT Rt -UPLOT Intermediate polarity porous polymer. Light gases in ethylene and propylene, ketones, esters....................................... 97 Polar porous polymer. More retention for polar compounds...................................................... 97 PLOT Column Phase Cross-Reference: Similar Performance Restek Porous Layer Agilent/J&W Supelco Alltech Varian/Chrompack Quadrex Rt -Alumina Aluminum oxide GS-Alumina, Alumina-PLOT AT-Alumina CP-A12O3/NA2SO4 HP PLOT S, HP PLOT M Rt -Msieve5A Molecular sieve 5A GS-Molsieve, Molsieve 5A PLOT AT-Molesieve CP-Molesieve 5A PLT-5A HP PLOT/Molesieve Rt -QPLOT DVB porous polymer Supel-Q-PLOT AT-Q CP-PoraPlot Q, PoraBond Q Rt -QSPLOT Intermediate polarity GS-Q porous polymer Rt -SPLOT DVB vinylpyridine CP-PoraPlot S polymer Rt -UPLOT DVB ethyleneglycol- HP-UPLOT CP-PoraPlot U, dimethylacrylate polymer PoraBond U

94 Rt -Alumina PLOT Columns did you know? Rt -Alumina PLOT columns show unique retention characteristics for hydrocarbons. Rt -Alumina PLOT Column Characteristics 1. Highly selective adsorbent for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers at temperatures far above ambient. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt -Alumina PLOT column is stable up to 200 C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 C. Full efficiency and selectivity will be restored. Selectivity The selectivity of the Rt -Alumina PLOT column is measured by the retention indices for acetylene and propadiene. These two components are extremely sensitive for a change in selectivity. For saturates, retention is determined mainly by the volatility of the compound, with less volatile compounds retained longer than more volatile compounds. For example, isoparaffins are less retained than less volatile normal paraffins of similar carbon number. For unsaturates, retention is strongly influenced by polarity or degree of unsaturation. In general, hydrocarbons having a higher degree of unsaturation are more polar. This polarity comes from the presence of π electrons; the more π electrons present in a compound, the more polar it behaves and the more strongly it is retained. Retention indices for some unsaturates separated on the Rt -Alumina PLOT column are listed in Table I. Sensitivity Proper deactivation is critical to minimize reactivity of the aluminum oxide stationary phase and maximize column sensitivity. Quantitation can be done only if the column exhibits linear response, which results from good stationary phase inertness. Rt -Alumina PLOT columns are specially deactivated and provide high inertness for unsaturates and saturates. In fact, Rt -Alumina PLOT columns are almost four times more sensitive for unsaturates than other brands on the market. Column sensitivities for various unsaturated hydrocarbons, measured by the peak height ratio based on n-butane, are shown in Table I. Table I: Retention indices and column response for unsaturates on an Rt -Alumina PLOT column at 80 C. Ethylene Acetylene Propylene Propadiene Retention Index 255 421 372 407 Peak Ratio (vs. n-butane) 0.65 0.72 0.84 0.54

Guaranteed Reproducibility Each Rt -Alumina PLOT column is tested with a hydrocarbon test mix to ensure proper phase thickness and deactivation. Pentane is used to calculate k (capacity factor), which is a measure of phase thickness. The ratio of isobutane to acetylene retention is measured to ensure proper deactivation of the alumina oxide layer. The plates per meter value is calculated to evaluate column efficiency. Rt -Alumina PLOT Columns 95 Restek s Rt -Alumina PLOT columns offer fast and reproducible hydrocarbon stream and purity analyses. The 0.32mm ID Rt -Alumina PLOT column provides fast and efficient analysis of C1 to C5 hydrocarbons. The higher capacity of the 0.53mm ID Rt -Alumina PLOT column makes it ideal for purity analysis of many common petrochemicals, such as 1,3-butadiene, ethylene, and propylene (see figure). Rt -Alumina Columns (fused silica PLOT) (Na2SO4 deactivation) ID df (µm) temp. limits 30-Meter 50-Meter 60-Meter 0.32mm 3 to 200 C 19702 19703 0.53mm 6 to 200 C 19700 19701 Propylene purity on an Rt -Alumina PLOT column. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1. methane 2. ethane 3. ethylene 4. propane 5. cyclopropane 6. propylene 7. isobutane 8. n-butane 9. propadiene 10. acetylene 11. trans-2-butene 12. 1-butene 13. cis-2-butene 14. isopentane 15. n-pentane 16. 1,3-butadiene 17. propyne Neil Mosesman Marketing Manager 20+ years of service! tech tip Trace water in the carrier gas can affect the selectivity and retention of the Rt -Alumina PLOT column. The column can be regenerated by baking out the water (50 C to 200 C @ 8 C/min., 50cm/sec. flow rate). Periodic conditioning ensures excellent run-to-run retention time reproducibility. The maximum programmable temperature for an Rt -Alumina PLOT column is 200 C. Higher temperatures cause irreversible changes to the porous layer adsorption properties. min. 2 4 6 8 10 12 14 GC_PC00185 Column: Rt -Alumina, 50m, 0.53mm ID (cat.# 19701) Inj.: 100µL hydrocarbon mix (gas-tight syringe) Oven temp.: 40 C (hold 3 min.) to 120 C @ 10 C/min. (hold 5 min.) Inj./det. temp.: 200 C Carrier gas: helium Linear velocity: 37.5cm/sec. set @ 80 C Split flow: 60mL/min. FID sensitivity: 1.28 x 10-10 AFS Table of Contents for Applications see pages 518-519 Searching for a chromatogram?

96 Molecular Sieve 5A PLOT Columns please note Rt -Msieve 5A PLOT columns are designed for efficient separation of Ar/O2 and other permanent gases, including CH4, C2H6, and CO. Rt -Msieve 5A PLOT Columns Rt -Msieve 5A PLOT columns are designed for efficient separation of Ar/O2 and other permanent gases, including CH4, C2H6, and CO. Special coating and deactivation procedures ensure chromatographic efficiency and the integrity of the porous layer coating. The high surface area of the Rt -Msieve is generated by the pore structure present in the molecular sieve. Only compounds that can enter the pores will be exposed to this surface and will be retained. Molecular sieves have very high retention, allowing separations of permanent gases at temperatures above ambient. Additionally, Restek s unique immobilization process guarantees that the uniform particles remain adhered to the tubing even after continuous valvecycling. tech tip Because molecular sieve materials are very hydrophilic, they will adsorb water from the sample or carrier gas. Water contamination can have a detrimental effect on peak symmetry and can reduce the resolution of all compounds. If water contamination occurs, reactivate your Rt -Msieve 5A PLOT column by conditioning at 300 C with dry carrier gas flow for 3 hours. Our revolutionary molecular sieve 5A PLOT columns separate Ar/O2 and H2/He at ambient temperature or above (see figure). These columns also are an excellent choice for rapid separation of permanent gases in refinery or natural gas. Our deactivation technology also allows the CO peak to elute as a sharp peak. This is in contrast with other suppliers where CO often tails badly and cannot be quantified below % levels. Permanent gases on an Rt -Msieve 5A PLOT column. Argon resolved from oxygen. 1. hydrogen 40ppm 2. argon 30ppm 3. oxygen 50ppm 4. nitrogen 50ppm 5. methane 40ppm 6. carbon monoxide 50ppm Excellent peak shape for carbon monoxide. did you know? ShinCarbon ST micropacked columns are another alternative for analyzing permanent gases. See page 116 for information. GC_PC00898 Column: Rt -Msieve 5A, 30m, 0.53mm ID, 50µm (cat.# 19723) Sample: permanent gases (ppm) Inj.: 5µL sample loop, 6-port Valco valve, valve temp.: ambient Inj. temp.: 200 C Carrier gas: helium, constant flow Linear velocity: 5mL/min. Oven temp.: 27 C (hold 5 min.) to 100 C @ 10 C/min. (hold 5 min.) Det.: Valco helium ionization detector @ 150 C Rt -Msieve 5A Columns (fused silica PLOT) 0.32mm 30 to 300 C 19720 19722 0.53mm 50 to 300 C 19721 19723

Porous Polymer PLOT Columns 97 Porous Polymers: Rt -QPLOT, Rt -QSPLOT, Rt -SPLOT, and Rt -UPLOT Columns Restek has developed unique polymer technology and coating processes, to make excellent porous polymer PLOT columns. Selectivity is similar to that of Porapak and HayeSep packings. Unlike molecular sieve and alumina columns, porous polymer PLOT columns are not moisture sensitive, making them particularly useful for applications in which moisture is of major concern. Chromatographic selectivity, in terms of polarity or chemical functionality, can be modified by incorporating polar functional groups in the styrene/divinylbenzene matrix. The least polar, or nonpolar, Rt -QPLOT columns are made with divinylbenzene. Rt -SPLOT columns incorporate 4-vinylpyridine, providing intermediate polarity. The new Rt -QSPLOT column has been engineered to have a polarity between the Rt -QPLOT and Rt -SPLOT columns. The Rt -QSPLOT column fully resolves ethylene, acetylene, and ethane. Highly-polar Rt -UPLOT columns are modified with an ethylene glycol/dimethylacrylate functional group to provide excellent selectivity for unsaturated compounds. Use these porous PLOT columns for a wide variety of separations. Permanent gases can be separated at subambient temperatures. Inorganic gases such as CO2 can be easily analyzed on porous polymer columns. For hydrocarbon analysis, tremendous versatility based on a choice of selectivity is advantageous. These columns also are designed for analysis of various polar and nonpolar solvents. Rt -QPLOT Columns (fused silica PLOT) 100% divinylbenzene 0.32mm 10 to 250 C 19717 19718 0.53mm 20 to 250 C 19715 19716 Rt -QSPLOT Columns (fused silica PLOT) porous divinyl benzene homopolymer 0.32mm 10-60 to 270/290 C 19739 19740 0.53mm 20-60 to 270/290 C 19737 19738 Rt -SPLOT Columns (fused silica PLOT) divinylbenzene 4-vinylpyridine did you know? New purification techniques have improved the peak shapes for polar compounds on our Rt -QPLOT columns. new! Intermediate polarity porous polymer Rt -QSPLOT Columns 100% resolution of ethylene, acetylene, and ethane. 0.32mm 10 to 250 C 19711 19710 0.53mm 20 to 250 C 19713 19712 Rt -UPLOT Columns (fused silica PLOT) divinylbenzene ethylene glycol/dimethylacrylate 0.32mm 10 to 190 C 19725 19724 0.53mm 20 to 190 C 19727 19726 Solvents on the nonpolar Rt -QPLOT column. 1 2 3 4 5 1. methane 2. methanol 3. ethanol 4. acetone 5. n-pentane 6. ethyl acetate 7. n-hexane please note Our porous polymer PLOT columns are not moisture sensitive, making them ideal for applications in which moisture is of major concern. Column: Rt -QPLOT, 30m, 0.32mm ID (cat.# 19718) Inj.: 20µL split injection. 50ppm (w/v) each in helium, Cyclosplitter inlet liner (cat.# 20755) Oven temp.: 150 C Inj./det. temp.: 200 C Carrier gas: hydrogen Det.: FID Split ratio: 20/1 6 7 Table of Contents for Applications see pages 518-519 min. 1 2 3 4 5 6 7 8 9 10 11 12 GC_PC00181