2010 edition. Handbook of. Fire-Rated Glass. for schools

Similar documents
FAQ S FREQUENTLY ASKED QUESTIONS ABOUT FIRE AND IMPACT/SAFETY RATED GLAZING PRODUCTS

Pyroguard Wired Glass

Fire-Rated Glass and Glazing START

From Wired Glass to Clear Solutions: Designing with Fire Rated Glass Today

The 60 minute Fire Rated Application Explained

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

New Product Announcement

Basic Fire Door Requirements

FIRE GLASS TO GO! Fire Glass Solutions from

Steel Door Institute. Fire Rated Doors and Frames

Building Code Clarifications - 7. Fire Resistance

Classroom Door Security & Locking Hardware

The replacement or modification of existing windows shall comply with the following requirements:

General Fire Code Requirements Within Commercial Tenant Spaces

Walking and Working Surface Checklist:

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

Current as of 11/10/08 1 of 1

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

City of Riverside Building & Safety Division Phone: (951)

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

Office of the State Fire Marshal. Fire Rated Doors

The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

PYROSWISS VETROFLAM CONTRAFLAM

FIRESTOPPING & SMOKE SEALS

Commercial Kitchen Fire Safety

Automatic Door Selection Guide

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Teach me about Glazing

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Installation Instructions

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Warehouse Checklist. Warehouse Construction

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

Fiberglas, Exterior Wall Thermal Insulation

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Elevating Your House. Introduction CHAPTER 5

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

FIRE RATED GLAZING System Guide

Arapahoe County Residential Water Heater Installation and Inspection Guide

Notes. Material 1. Appropriate Flammable Liquids

Glass and Building Regulations Impact Safety

How To Test For Premer Retardant

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Solar Panel Installations

Fire-Rated Doors and Hardware. A Guide to Field Inspection

CHAPTER 24 GLASS AND GLAZING

Overview of Hotel Fire Safety Requirements

Tremco Fire Protection Systems Group Technical Bulletin

Architect/Contractor Information Package

BUILDING PERMIT SPECIFICATIONS

HOT WORK PERMIT PROGRAM TRAINING. John Braun

NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

TOWN OF BRENTWOOD TH PLACE BRENTWOOD, MD (301) FENCE PERMIT APPLICATION

17,280 square feet Overview:

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

Georgia Tech Aerospace Server French building Server Room. Server Room Policy Handbook: Scope, Processes and Procedure

White Paper FIRE DOOR INSPECTIONS, REPAIRS AND LABELING

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

Impact-Resistant Windows and Sliding Glass Doors

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Code Requirements for Existing Buildings

Name Of Occupancy Date. Yes No Describe

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

EXHIBITION DISPLAY RULES

All You Ever Wanted to Know About Fire Extinguishers...

CHILD CARE CENTER INFORMATION SHEET

Terms and Definitions In Canada

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

Fire Safety Requirements for Child Care Centre

Indiana Building Rehabilitation Standard

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

ELEVATED WORK POLICY

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

COMMERCIAL BUILDING APPLICATIONS

St. John s University

Fire-Retardant-Treated (FRT) Plywood

GENERAL FIRE SAFETY TERMS & DEFINITIONS

FIRE-RESISTANCE-RATED CONSTRUCTION

Transcription:

Handbook of Fire-Rated Glass for schools 2010 edition

The Rules have changed For decades, traditional wired glass has been the most common fire-rated glass product specified for schools in North America. It s no wonder -- it provides economical and reliable fire protection. And for a long time, wired glass was the only product available that could do the job. But there is a down side: Despite its tough appearance, traditional wired glass can t tolerate much impact. And when it breaks, the wires can form snags that are capable of inflicting serious injury. When fire codes were first being drafted, traditional wired glass was the only glazing material that could offer any fire protection. So when high traffic areas called for a fire rating, wired glass was granted an exemption from meeting impact safety requirements. The consensus was that the risks posed by fire were greater than the risks posed by breakage. But fire safety without impact safety isn t enough when you have a corridor filled with students jostling each other on their way to class. In such settings, traditional wired glass 800.426.0279 fireglass.com

can represent a potential for problems. Realizing this, the International Code Council (ICC) decided to lift the long-standing impact exemption for wired glass. Now, all fire-rated glass in K-12 schools and athletic facilities, when used in hazardous locations (doors, sidelites, etc.), must meet the higher impact requirements. 2010 edition This is a monumental shift, having far-reaching implications. The following pages answer some of the most common questions that have been raised because of this change. IBC 2006 SECTION 2406 SAFETY GLAZING 2406.1 All glazing in hazardous locations as defined in Section 2406.3 shall comply with the impact test requirements in Sections 2406.1.1 through 2406.1.4. 2401.6.1.1 CPSC 16 CFR 1201. Except as provided in Sections 2406.1.2 through 2406.1.4, all glazing shall pass the test requirements of CPSC 16 CFR 1201, listed in Chapter 35. Glazing shall comply with the CPSC 16 CFR, Part 1201 criteria, for Category I or II as indicated in Table 2406.1. Sections 2406.1.1 through 2406.1.4 do not list wired glass as an exemption. Therefore, traditional wired glass is no longer allowed in safety impact areas. What distinguishes fire-rated glass from ordinary glass? Like most glass, fire-rated glazing allows light and visibility for aesthetic or security reasons. But fire-rated glass does something more: It has been tested to act as a barrier to the spread of flames and smoke. In the world of fire protection, this is known as compartmentation. Unlike sprinklers or other active protection systems, fire-rated glass is on duty 24 hours a day. If there is a power failure, a loss of water pressure, or a human error that interferes with the sprinklers working properly, fire-rated glass will not be affected and will continue to perform as needed. Staying in place during a fire may sound like a fairly simple task, but no ordinary glass can do it.

What testing does fire-rated glass have to pass? Glass and framing are installed vertically in the test furnace of an independent test laboratory, such as Underwriters Laboratories, Inc. (UL). The fire is ignited and temperatures are measured on the surface of the glass. Ratings are given based on the length of time the glass remains intact, from 20 minutes to 3 hours. Ordinary window glass can withstand temperatures of approximately 250 F. However, after only 5 minutes, a real world fire (and the fire test) temperatures reach nearly 1,000 F. Glass that withstands an hour in the fire test is subjected to nearly 1,700 F. At the conclusion of the fire test, to achieve a rating greater than 20 minutes, the glass is required to be subjected to the impact pressure and thermal shock of water from a two-man fire hose. This tests the ability of the glass and framing system to stay in place if structural damage takes place. It also proves the glass will stay in its protective position to block passage of flames and the deadly smoke, if subjected to the cooling effect of water from sprinklers or fire extinguishers. THE TESTING GROUND What is the impact safety test for glass? A 34" x 76" piece of glass is mounted in a vertical frame. A punching speed bag is filled with 100 pounds of lead shot (similar to BB s found in shotgun shells). This very heavy bag is hung from a cable and swung, in pendulum fashion, from various heights to impact the glass. The velocity of the bag, at high impact levels (CPSC 16 CFR 1201 Category II), corresponds to the impact of a full grown adult running into the glass. To qualify for an impact safety rating, glass must either not break, or break in a safe manner. 800.426.0279 fireglass.com

Are there different levels of impact safety for glazing materials? Yes. This issue is extremely important in schools and relates to the impact safety test and the level from which the impact bag is dropped. The various impact ratings are very revealing. Let s start with the most common level of impact safety and work our way to lower levels. 2010 edition 48-inch drop This represents 400 ft/lb of impact, and is called Category II by the Federal CPSC (Consumer Products Safety Commission). It is the highest level of required impact safety. This represents the impact of a full-grown adult running into the glass with insignificant or no injury. With few exceptions, all tempered or laminated safety glass in use today falls into this category. More important, there are numerous products available today that meet this impact rating and also offer high levels of fire protection. 18-inch drop This represents 150 ft/lb of impact, and is called Category I by the CPSC. Glass that can only meet this test is limited to a maximum size of 9 square feet per lite (or less). This roughly represents the expected impact from an 85 lb child running into the glass. 12-inch drop This represents only 100 ft/lb of impact and was created as an exception for wired glass. It indicates the glass may only withstand the impact of a very young child. This impact level, which could only protect very small children, is now prohibited from use in ALL types of buildings (including educational facilities) per IBC 2006.

When using glass in fire-rated locations, is impact safety glass always required? No. Building codes clearly define where impact safety glass is required. Common applications for high impact glass are doors, sidelites, glass located near the floor, and other hazardous locations, as defined by building codes. In those areas, any fire-rated product would also need to be impact safety-rated. In areas where human contact is not a concern (transoms, some windows) an impact rating would not be required. For those areas, there are fire-rated products that are not impact rated which are generally less expensive than glazing that offers both fire and impact protection. However, keep in mind that schools are high activity areas that can present abnormal situations. A window in the middle of a school wall that doesn t technically require impact safety ratings may still fall victim to the energy of students pushing and shoving. Therefore, it may be best to err on the side of caution and use an impact safety-rated product even when codes don t demand it. think safe 800.426.0279 fireglass.com

If, due to the International Building Code (IBC), I m no longer using traditional wired glass in hazardous areas, what products are available? There are two primary categories of alternatives to wired glass that can be labeled as Thin and Thick glass. 2010 edition THIN There are now several products with or without wires that make outstanding alternatives to traditional wired glass. The FireLite family of products and WireLite NT are examples. Approximately 1/4" to 5/16" thick, they fit in standard fire-rated frames. Depending on the product, these newer materials are available in large sizes and have fire ratings from 20 to 90 minutes (up to 3 hours in small door lites). Thin glass products such as FireLite are classified as opening protective that block smoke and flames but are not a barrier to heat. Thin products are available with or without impact safety ratings and can be cut and labeled locally throughout North America - so availability is nearly immediate. THICK These special glass products are commonly called glass walls because they allow virtually unlimited expanses of glass. Tested to the same standards as solid barrier walls, glass walls block heat in addition to flames and smoke. If more than 25% of the openings in a corridor contain glass, then these products should definitely be considered. During a fire, the ability of the glass to block heat transfer will allow safe passage from the building. These glass products may be 3/4" thick or greater, depending on required fire rating, so appropriate window and door framing may be a consideration. As special cutting and processing equipment is needed for the glass wall materials, delivery is slightly longer than thin products. think ahead

What special considerations should be taken into account when choosing fire-rated glazing for schools? Schools are unique in the construction industry, because they raise several issues that typically do not arise with other occupancies. High Activity Educational facilities are subject to greater activity than a typical office building. The constant movement of students throughout the day means that impact safety must be a high priority. Abuse School hallways and common areas are likely to be defaced, either intentionally or unintentionally. The fire-rated glazing chosen should be durable. Products relying on a surface film for impact safety may not be the best choice for these locations. Maintenance For building and life safety (not to mention legal considerations), damaged products must be replaced or repaired in short order. Be sure the product you choose will be durable and available locally. Longevity Schools are expected to operate for many years. Since school construction and maintenance budgets are tight, it is very important that building products stand up over time. Why not just apply a safety film to wired glass? As we mentioned before, schools are more prone to abuse than other types of facilities. Even the toughest films can be marred, lacerated or peeled. The film can be damaged by vandals, or unintentionally by maintenance personnel or just daily use. When the film is damaged, it not only is unsightly -- it can impair the performance ability of the product and render the impact ratings invalid. It s also important to note that not all surface-applied film is fire-rated. If you do choose to use a filmed product, make sure it has been tested for fire and impact, and is listed by an independent testing agency. We are not opposed to the use of surface-applied film, we even sell a fire-rated product that has a film applied for impact safety. However, for maintenance reasons, we simply do not recommend its use in high traffic areas such as schools. 800.426.0279 fireglass.com

What specific products do you recommend for schools? For high traffic, hazardous locations, that previously used wired glass, we recommend FireLite Plus. It meets the CPSC 16 CFR 1201 (Category II) impact requirements. The high impact laminating materials are sandwiched between two lites of clear glass ceramic, so both exposed surfaces are durable. FireLite Plus can be cut with normal glass cutting tools, which means it can be delivered quickly from school maintenance personnel or local glazing contractors. In non-impact rated areas, we recommend FireLite. At only 3/16" thick, it easily fits into new or existing fire-rated frames. Like FireLite Plus, FireLite can be cut locally for quick delivery. And since it is a ceramic, it has a surface even more durable than regular glass. 2010 edition WireLite NT is another alternative. This 1/4" thick product is composed of wired glass and high performance fire-rated surface-applied film. The result is a product that meets Category I and II impact levels. When should I use the thick glass that is a barrier to heat transfer? These products are typically used where large expanses of glass are required, i.e., where glazed areas exceed 25% of the wall area. Their ability to block heat transfer can prove invaluable when protecting exit corridors. And the benefit of blocking heat is sometimes considered, even when heat blockage is not required by building codes. Due to the need for special cutting and processing equipment, delivery must be direct from the manufacturer. This extended lead time is a consideration if glass requires immediate replacement. With a typical thickness of at least 3/4", frames and glazing stops may require modification to ensure proper assembly. Having said that, there are many times when such a product is the best choice. In those instances, we recommend Pilkington Pyrostop. Pilkington Pyrostop is available in a broad range of make-ups for interior and exterior use, with ratings from 45-minutes up to 2 hours.

Aren t the newer fire-rated products more expensive? The initial investment for the newer, high performance glazing materials is greater than traditional wired glass. The old saying, you get what you pay for holds true: As with most things in life, the greater the level of performance desired, the greater the cost. But you should also consider the life of the product after it is installed. Schools are designed to last more than 30 years. As discussed, products with surface applied films will require more maintenance over that time. For fire-rated glazing, it s better to base your decision on long term safety and durability rather than initial purchase price alone. Specifying the lowest cost option up front can leave open the door for costly accidents, injuries or repairs down the road. 2010 edition THE RIGHT INVESTMENT 800.426.0279 fireglass.com

PRODUCT COMPARISON CHART / ACOUSTICS Product Maximum fire rating Offers impact safety** Passes hose stream test Blocks heat transfer during fire Complies with energy codes Compatible with TGP framing Provides acoustic barrier Advantages/ Disadvantages Fireglass 20 20 min. + Moderate initial investment - Cannot withstand thermal shock Pilkington 20 min. Pyrodur + Moderate initial investment - Cannot withstand thermal shock Wired Glass 45 min. + Least expensive option - Institutional appearance - Low impact resistance - Limited sizes WireLite 45 min. + Moderate initial investment WireLite NT 90 min. + Surface-applied fire-rated film + Cat. I and II impact safety + Withstands thermal shock + Passes hose stream test - Possible abuse to surface film FireLite 90 min. + Heat resistance of ceramic - Low impact resistance FireLite NT 3 hrs.* + Surface-applied fire-rated film + High impact resistance - Possible abuse to surface film FireLite Plus 3 hrs.* + Durable laminated construction + High impact resistance FireLite IGU 3 hrs.* + Energy efficient + Acoustic barrier + Wide choice of appearances Pilkington 2 hrs. Pyrostop + + Floor-to-ceiling glass designs + Reduces heat transfer + Tested as a wall - Can be heavy *For doors. Consult product literature for maximum ratings in other openings. **Meets CSPC 16CFR1201 (Cat. I or II) + In an IGU make-up. 800.426.0279 fax: 800.451.9857 sales@fireglass.com fireglass.com THICK THIN

8107 Bracken Place SE Snoqualmie, WA 98065 fireglass.com 2010 Technical Glass Products. FireLite and FireLite Plus are registered trademarks of Nippon Electric Glass Co., Ltd. Pilkington Pyrostop and Pilkington Pyrodur are registered trademarks of Pilkington plc. WireLite is a registered trademark of Technical Glass Products. Technical Glass Products, One Source. Many Solutions., Fireglass and Fireframes are registered trademarks of Technical Glass Products.