Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system



Similar documents
Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS

Quick Connect. quick - simple - efficient.

E-STOP relays, safety gate monitors

How To Use A Sim Sims 2.2 (Blackberry) With A Sims 3 (Blackintosh) And Sims 4 (Blackburn) (Blackford) (Whiteford) For A Long Time (Blackwood) (Blue

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

PNOZsigma - Base units

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Barcode Reader Series BCL 31, BCL 32, BCL 34

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ZC-24DO CANopen I/O Module: 24 Digital Outputs

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Telephone- and leased line modem for industrial applications TD-36

E-STOP relays, safety gate monitors

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Safety automation solutions

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Rack mounted telephone- and leased line modem for industrial applications

MasterINTERFACE 39 Series - Relay interface modules

mecotron Safety relay ESTOP-2 For emergency stop monitoring

TX OPEN RS232/485 module

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Multifunction devices

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

E-STOP relays, safety gate monitors

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Model: DC-A2IO Advanced HVAC Controller

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Contact expansion modules

IntesisBox KNX LG Air Conditioning

Safety technique. Emergency stop module BO 5988 safemaster

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Hardware Manual RM CANview Ethernet

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Fieldbus slave modules with I/Os, DIO

Technical Data. back-up time in minutes 100% load % load

connecdim Gateway G1 Ethernet TCP/IP to DALI

Control Devices Catalogue. Control Devices. Preferred and Standard Products

E-STOP relays, safety gate monitors

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Digital display DA 48

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

is then retained absolutely without interruption.

FIREDEX Conventional Fire Panels

Power Supplies 3. SDN-P DIN Rail Series

Thyristor-controlled power supplies and battery chargers

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

E-STOP relays, safety gate monitors

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

E-STOP relays, safety gate monitors

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

Digital input modules

Product Information Sheet UH36 Hi Pot Tester

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Multi-Range Programmable DC Power Supplies 9115 Series

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

TMS TANK MANAGEMENT SYSTEM

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

Digital Single Axis Controller

MasterINTERFACE 39 Series - Relay interface modules

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

J TB/TW Temperature limiter, temperature monitor

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Thermal-Magnetic Circuit Breaker M1-..

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

TX2123 RS485 TO ETHERNET ADAPTOR

PNOZ s3. Safety relays. Operating Manual EN-10

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Electronic Control Devices The European Product Catalogue 2007

SMS 4 / SMS 5 safety mat Product information

Inwall 4 Input / 4 Output Module

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

NX safety stand-alone

MSI-s/R. Modular Safety Interface. CONNECTING AND OPERATING INSTRUCTIONS Original Instructions. without prior notice /05.

Actuator-Sensor-Interface

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Control- and feedback head for integrated mounting on Robolux valves Type 2036

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation

Transcription:

E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Expandable with a safe bus system Reduction of expenditures in Mounting and Installation Easy programmable Software modules tested and certificated Safety category 4 according to EN 954-1, SIL 3 according to IEC 61508

Fiessler Programmable Safety Center FPSC System descriptiong The FPSC Fiessler Programmable Safety Center is a programmable electronic safety controller for personal protection, i.e. for safety functions. The FPSC complies with the highest safety requirements: SK1 up to SK 4 according to EN 954-1 SIL 1 up to SIL 3 according to EN IEC 61508 PL a up to PL e according to pren 13849-1 The product family FPSC provides maximum flexibility within its hardware and software structure. The FPSC - AD version offers the possibility to connect decentralized I/O modules via the implemented safe bus system. This guarantees a modular system design that offers flexibility therefore reducing the costly and often elaborate configuration of the safe system bus. The safety-related functions are programmable by using pre-assembled and tested software modules. The chaining is made by simple assignment of input, i.e. output adresses. Intermediate data are stored in the temporary storage. There are various ready-to-use software modules at your disposal. For the communication with a superior control, i.e. for the operating sequence control or technology control, a serial interface is provided. The transfer of data for visualizing as well as the transfer of machine-relevant data can de realised via this interface The simple snap-on mechanism for fastening the items on a top hat rail in the control cabinet considerably reduces the installation expenditure of the items of the product family. Overview of the product family FPSC, hardware : safe base units FPSC - B, basic configuration 32 safe inputs 4 fast safe inputs 4 fast safe outputs 4 fast outputs, bi-polar switching 8 safe outputs, monopolar switching 2 serial interfaces FPSC - AD, enhanced configuration 32 safe inputs 4 fast safe inputs 4 fast safe outputs 4 fast outputs, bi-polar switching 8 safe outputs, monopolar switching 2 serial interfaces for enhancing by decentralized I/O modules Doku Nr 953 Stand 15.9.2005 / FM - page 2

Overview of the product family FPSC, hardware: safe decentralized modules FPSC - RS8I, decentralized input module 8 safe inputs FPSC - RS16I, decentralized input module 16 safe inputs FPSC - RS24I, decentralized input module 24 safe inputs FPSC - RS4O, decentralized output module 4 safe outputs FPSC - RS8O, decentralized output module 8 safe outputs FPSC - RS12O, decentralized output module 12 safe outputs FPSC - RS8I4O, decentralized input/ output module 8 safe inputs 4 safe outputs FPSC - RS8I8O, decentralized input/ output module 8 safe inputs 8 safe outputs Doku Nr 953 Stand 15.9.2005 / FM - page 3

Overview of the product family FPSC, hardware: safe decentralized modules FPSC - RS16I4O, decentralized input/ output module 16 safe inputs 4 safe outputs Overview of the product family FPSC, hardware: non-safe decentralized signalling modules FPSC - RM8IN, decentralized input module 8 non-safe inputs, common negative potential 1 CAN bus interface FPSC - RM8ON, decentralized output module 8 non-safe outputs, common negative potential 1 CAN bus interface Doku Nr 953 Stand 15.9.2005 / FM - page 4

Overview of the product family FPSC, software FPSC - PR-S, Programming software Software to program the base units S: single user license M: multi-user license FPSC - Diag, Diagnosis and Analyzing Software Software for the back-analyzing of the application program and for visualizing of both inputs and outputs, for the visualization of the status of the flags and of the system status. S: single user license M: multi-user license Overview of the product family FPSC, accessories FPSC - RS232 cable Cable between the programming unit (PC, Notebook etc.) and the base units for programming the parameters FPSC - USB / RS232 adaptor Interface converter from USB standard to RS232 for entering the parameters into the base units FPSC - CAN cable cable for the safety-related networking of the decentralized modules and the base unit Doku Nr 953 Stand 15.9.2005 / FM - page 5

Technical Data Product Family FPSC Technical Data Field of application Safety relevant classification Electrical data Power supply Tolerance range Load current Protection of the power supply Connections: power supply Input level output level CAN-connector (optional) Interfaces Minimum response times High Speed inputs => High Speed outputs Mecanical data Dimensions (HxBxT) FPSC - B, FPSC - AD parameterizable safety control with optional safety-related bus interface up to category 4 according to EN 954-1 up to SIL 3 according to EN IEC 61508 up to PL e according to pren 13489-1 FPSC - B, FPSC - AD 24 V DC 19,2... 30,0 V DC max. 10% residual ripple typ. 350 ma T 6,3 A Plug base with screw terminals max. 2,5 mm2 max. 1,5 mm2 max. 2,5 mm2 Sub-D plug 9-pin RS 232 Programming interface RS 232 User interface 1 ms FPSC - B, FPSC - AD 127 x 390 x 80 mm Mounting on top hat rails according to DIN 50 022 Protection class of the housing IP 20 Inputs FPSC - B, FPSC - AD Number of safe standard inputs 32 Number of safe high speed inputs 4 Galvanic isolation yes Signal level at log "0 0... 2 V DC Signal level at log "1" 15... 28 V DC Input current 5 ma (bei 24 V) Minimum impulse duration at 20 ms the standard inputs Status displayed via LED Single Pole Outputs FPSC - B, FPSC - AD Number of safe standard outputs 8 Number of high speed outputs 4 Galvanic isolation yes Output current at log "1" max. 2 A Short-circuit protection electronic Status displayed via LED Dual Pole Outputs FPSC - B, FPSC - AD Number of safe dual pole outputs 4 Galvanic isolation yes Output current at log "1" max. 2 A Short-circuit protection electronic Status displayed via LED Protection class of the terminals IP 20 Weight 1,65 kg Environmental conditions FPSC - B, FPSC - AD Operating temperature 0... +60 C Storage temperature Relative humidity -25 C... +70 C 30%... 85% RH Striking and creep distances DIN EN 50 178 Vibrations DIN EN 60 068-2-6 EMC DIN EN 61 000-6-2 Bedewing / Condensation not permitted Doku Nr 953 Stand 15.9.2005 / FM - page 6

Technical Data decetralized modules FPSC - RSxxx Technical data Field of application Safety relevant classification Electrical Data Power supply FPSC - RSxxx Enhancing of the base units FPSC-B, FPSC-AD by safety- related inputs and outputs Up to category 4 according to EN 954-1 Up to SIL 3 according to EN IEC 61508 Up to PL e according to pren 13489-1 FPSC - RSxxx 24 V DC Tolerance range 21,6... 26,4 V DC max. 10% residual ripple Load current typ. 350 ma Protection of the power supply Connections: power supply Input level output level CAN-connector (optional) Mechanical data Dimensions (HxBxT) T 6,3 A plug base with screw terminals max. 2,5 mm2 max. 2,5 mm2 max. 2,5 mm2 Sub-D Stecker 9 polig FPSC - RSxxx 127 x 127 x 120 mm Mounting on top hat rails according to DIN 50 022 Protection class of the housing IP 20 Protection class of the terminals IP 20 Inputs Number of safe standard inputs Galvanic isolation Signal level at log "0 Signal level at log "1" Input current Minimum impulse duration at the standard inputs Status displayed via Dual Pole Outputs Number of safe dual pole outputs Galvanic isolation output current at log "1" short-circuit protection Status displayed via FPSC - RSxxx 8, 16, 24, according to the required configuation yes 0... 2 V DC 15... 28 V DC 5 ma (bei 24 V) 20 ms LED FPSC - RSxxx 4, 8, 16, according to the required configuation yes max. 0,5 A electronic LED Weight 1,0 kg Environmental Conditions FPSC - RSxxx Operating temperature 0... +45 C Storage temperature Relative humidity -25 C... +70 C 30%... 85% RH Striking and creep distances DIN EN 50 178 Vibrations DIN EN 60 068-2-6 EMC DIN EN 61 000-6-2 Bedewing / Condensation not permittel EMV DIN EN 61 000 6 2 Doku Nr 953 Stand 15.9.2005 / FM - page 7

Overview of the available software modules Software module Emergency OFF Safety switch Interlocking device, locked by snap-switch Interlocking device, locked by magnet Time delay Gate control Contact multiplication Pulse latch Flip Flops Enabling mode single-channel (NA) double-channel (NA) Reset Start button / Autostart feedback circuit Yes / No switch-on testing Yes / No cyclic (repeated) test Yes / No single-channel (Sis) double-channel (SiS) Reset Start button / Autostart feedback circuit Yes / No switch-on testing Yes / No cyclic (repeated) test Yes / No single-channel (TZF) double-channel (TZFW) Reset Start button / Autostart feedback circuit Yes / No switch-on testing Yes / No cyclic (repeated) test Yes / No single-channel (TZM) double-channel (TZMW) Reset Start button / Autostart feedback circuit Yes / No switch-on testing Yes / No cyclic (repeated) test Yes / No OFF-delay ON-delay timer AND NOT AND OR NOT OR each of them with 8 inputs 1 input up to 8 outputs level triggering edge triggering D-Flip Flop and RS-Flip Flop Energy (with permissive switch) Drive (mit Tipp) Energy (no permissive switch) Doku Nr 953 Stand 15.9.2005 / FM - page 8

Overview of the available software modules Software modules BLVT AKAS 1 and 2 AKAS 3 Overrun traverse measurement Muting Valve monitoring Module for programming the different operating modes of the Fiessler Elektronik BLVT safety light curtains product series Module for the evaluation of data of the AKAS I or AKAS II systems Module for the evaluation of data of the AKAS III system For monitoring the overrun traverse of a press, e.g. of a press brake Module for the control and evaluation of the Muting functions Module for triggering and monitoring of hydraulic valves/contactors Operating mode selctor switch Safe selector switch for selecting the operation modes (1 out of 8) Filters Module for the input filter adjustment of the High speed inputs in 16 stages Two-hand control Module for evaluation of data of a two-hand control panel Doku Nr 953 Stand 15.9.2005 / FM - page 9

Doku Nr 953 Stand 15.9.2005 / FM - page 10