Fiber in the Data Center



Similar documents
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Data Center Design for 40/100G

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

The Need for Low-Loss Multifiber Connectivity

How To Make A Data Center More Efficient

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

Loss & Continuity Testing with MPO/ MTP Connectors

Overcoming OM3 Performance Challenges

Understanding Fiber Polarity: Implications at 10G, 40G, & 100G

With the advent of Gigabit Ethernet

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

MPO. Fast Fibre Solution for Data Centres

Obsolete Fiber Technology? Not in my Data Center!

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

Patch Cords for Data Center Applications

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

Corning Cable Systems Optical Cabling Solutions for Brocade

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

OCTOBER Layer Zero, the Infrastructure Layer, and High-Performance Data Centers

Zone Distribution in the Data Center

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

Secure/Keyed LC System Solutions Overview

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

The Three Principles of Data Center Infrastructure Design WHITE PAPER

Fiber Selection and Standards Guide for Premises Networks

CISCO 10GBASE X2 MODULES

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network

Data Center Cabling Technology and Trends

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

Arista and Leviton Technology in the Data Center

Attaching the PA-A1-ATM Interface Cables

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?

The 8-Fiber Solution for Today s Data Center

How To Make A Fibre Cable For A Data Centre

How To Properly Maintain A Fiber Optic Infrastructure

AMP NETCONNECT Data Center Cabling Solutions

10G and Beyond in the Data Center with OM3 Fiber

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

Polymer Coated Fiber Cable (PCF)

DATA CENTER SOLUTIONS GUIDE

PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS

MIGRATING TO A 40 GBPS DATA CENTER

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

Fibre optic testing best practices

Sustaining the Cloud with a Faster, Greener and Uptime-Optimized Data Center

Corning Cable Systems Optical Cabling Solutions for Brocade

Fiber Systems. Best Practices for Ensuring Polarity of Array-Based Fiber Optic Channels

TIA Releases Guidelines for Maintaining Polarity Using Array Connectors

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

How To Get A Better Signal From A Fiber To A Coax Cable

The Conversion Technology Experts. Fiber Optics Basics

Optimizing Infrastructure Support For Storage Area Networks

ADC KRONE s Data Centre Optical Distribution Frame: The Data Centre s Main Cross-Connect WHITE PAPER

Plug & Play Universal Systems

DATA CENTER DESIGN BEST PRACTICES: EFFICIENCIES BEYOND POWER AND COOLING

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

SYSTIMAX Copper Solutions Designed for the Digital Generation

Upgrading Path to High Speed Fiber Optic Networks

WHITE PAPER. 50 versus 62.5 micron multimode fiber

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

HP Multimode OM3 LC/LC Optical Cables Overview. Models HP 50 m Multimode OM3 LC/LC Optical Cable

Enabling 21 st Century Connectivity

Parallel SMF (PSM) in the Data Centre

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

InstaPATCH ZERO Solution Guide

Implementing Fast Ethernet

High density Fiber Optic connections in the Data Center. Phil Ward Datacenter Product Market Manager. HUBER+SUHNER AG

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

Data Center Architecture with Panduit, Intel, and Cisco

100BASE-SX Fast Ethernet:

Uniprise Solutions. Ten Good Reasons To Choose CommScope.

Infrastructure for the next three generations

Data Center Topology Guide

Living Infrastructure Solution Guide.

Cisco SFP Optics for Gigabit Ethernet Applications

HUBER+SUHNER AG Phil Ward

Structured and Point to Point Network Cabling for Industrial Automation

Pretium EDGE HD Solutions

Data Centre & Enterprise Solutions. RapidNet

Arista 40G Cabling and Transceivers: Q&A

Security & Surveillance Cabling Systems

Simplified 40-Gbps Cabling Deployment Solutions with Cisco Nexus 9000 Series Switches

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

Transcription:

Fiber in the Data Center A NetClear White Paper Rudy Montgelas Senior Fiber Product Manager Ortronics/Legrand Lisa Huff Data Center Applications Engineer Berk-Tek, A Nexans Company March 2008 A New Generation of Low-Loss, Modular Cassette-Based Systems Enhance 10-Gb/s Performance

Today s data centers (DC) present a challenge in meeting critical business needs in the face of burgeoning transactions and exploding amounts of information that must be stored and managed. With over five exabytes of new information being generated each year globally, even modest data centers must flexibly meet demands for growth in a high-reliability environment. While expansion can be accommodated by adding new servers and storage, it is also met by increasing bandwidth to allow more transmissions per second. Data rates have progressively moved from 10 Mb/s through 100 Mb/s and 1 Gb/s to today s 10 Gb/s and tomorrow s 40 or 100 Gb/s. As data rates increase, the use of fiber-optic cabling in the DC is becoming more commonplace. Advances in optical technology make fiber more affordable, more practical, and easier to use in the data center. These improvements include: 50-micron laser-optimized multimode fiber (LOMF) that allows cable runs of 300 meters at 10 Gb/s with traditional LOMF. Up to 600 meters is possible with a new generation of enhanced LOMF, exemplified by Berk-Tek GIGAlite -XB cable. As will be shown, this second generation of LOMF gives even greater flexibility in meeting the needs of DCs. Vertical-cavity surface-emitting lasers (VCSELs) that lower the cost of optical transceivers. Since they are well matched to LOMF at a wavelength of 850 nm, they make the use of multimode fiber economically attractive. Cassette-based interconnects that speed the installation of fiber-based cabling systems and simplify the on-going management of the system. The Momentum series of cassettes from Ortronics/Legrand offer improved performance over legacy cassettes of just a few years ago. The Benefits of Cassette-Based Fiber Interconnects Multi-fiber cables terminated with industry-standard MTP /MPO array connectors simplify use of fiber in the DC. The cables significantly reduce congestion in pathways, provide the highest port densities (12 fibers in a 0.5 x 0.3-inch area), and simplify system design, installation, and management. While fiber ribbon cables are popular for array connections, new reduced-diameter cables, such as Berk-Tek s Micro Data Center Plenum (MDP) cable, are setting a new standard in DC cabling. As shown in Figure 1, the diameter of a 48-fiber MDP cable is less than half that of a stacked ribbon cable of the same capacity and only one-third of a similarly configured Loose- Tube Plenum (LTP) cable. When properly applied, reduced-diameter cables improve air flow and aid in dissipating heat in the computer room. * MTP is a registered trademark of US Connec Figure 1. Reduced-diameter cables save space in crowded conduits. The companion cassettes, as shown in Figure 2, perform the transition from the multi-fiber array to individual SC or LC patch cords. A single cassette can typically handle 12 or 24 fibers in a single unit and up to 12 cassettes fit in a standard 4U 19-inch rackmount fiber patch panel. Installation of the cassette is simple (Figure 3). The cassettes are inserted into the fiber patch panel, and the array cable is plugged into the back of the cassette and patch cords connect to the front. This plug-and-go simplicity means extremely fast and reliable installation when compared to field installing fiber connectors. Copyright 2008 Berk-Tek, a Nexans Company and Ortronics/Legrand, All rights reserved.

Design Considerations Using LOMF multi-fiber interconnect cables and cassettes is straightforward. A primary design consideration is ensuring that the system stays within the channel insertion loss budget for a particular application. This budget is simply predetermined by the application (such as 10GBASE-SR). Therefore, the attenuation of the patch cord and backbone cable, associated connector insertion loss, and the insertion loss value of the cassettes should not exceed the channel insertion loss budget. (A free link-loss calculator is available from NetClear at www.netclear-channel.com/calculator. It is an easyto-use spreadsheet that automatically calculates loss based on component choices and link lengths.) Figure 2. A fiber cassette acts as a transition between a MTP/ MPO-based multi-fiber backbone and LC- or SC-terminated patch cords (shown with cover removed for clarity). The sum of these individual losses must be less than the maximum channel insertion loss specified for the application running over the cabling system. As new higher-data-rate networking protocols enter the market, the link budget for the channel diminishes. One of the reasons for shrinking link budgets is that the standards groups, which defined new high-speed protocols conservatively, accounted for certain link penalties. The available channel loss budget is what remains after these penalties are factored into the total loss budget. For example, intersymbol interference (ISI), which can cause bit errors when adjacent data pulses spread and overlap one another, is a major penalty in the overall power budget. As shown in Figure 4, the impact of ISI on overall loss budget is comparable to channel insertion loss, with over 75% of the total loss budget coming from these two factors Figure 3. Fiber cassettes offer the simplicity of plug-and-go application. Cassettes can mount in standard 19-inch or 23- inch rack-mount cabinets, wall-mount enclosures, and under-floor boxes. All components cable assemblies and cassettes are factory terminated and tested so that there is no field preparation involved. And because the components are provided with the test data on a label conveniently affixed to the cassette housing, any field testing results can be verified quickly and easily. The ISI penalty in the 10G standard was calculated using a 50-micron LOMF (OM-3) with a modal bandwidth of 2000 MHz km. The modal bandwidth is primarily limited by the fiber characteristic of differential model delay (DMD), which causes ISI due to pulse spreading. A new generation of LOMF improves the modal bandwidth to 4900 MHz km at 850 nm using today s VCSELs. As we will discuss next, this has important consequences on the application of fiber cassettes in the data center. Copyright 2008 Berk-Tek, a Nexans Company and Ortronics/Legrand, All rights reserved.

provides great flexibility for both the designer and installer. Figure 5 summarizes channel budgets and illustrates the maximum number of cassettes possible using different cassette grades. Figure 4. 75% of the total loss budget is allocated to ISI and channel insertion loss in IEEE 802.3ae. Channel Insertion Loss Assuming a fiber having an effective modal bandwidth of 2000 MHz km at 850nm and a fixed link length of 300 meters, the budget for channel insertion loss for 10-Gb/s Ethernet is a tight 2.6 db. With the new 4900 MHz km LOMF, and conservatively compensating for connector modal noise, it becomes possible to reallocate up to 1.9 db of the ISI penalty to the channel loss yielding a more generous 4.5 db budget of channel insertion loss. At the same time, fiber cassettes, backbone cables, and patch cords have been improved to offer lower component insertion loss. Ortronics Momentum cassettes are offered in two performance tiers, with progressively improved insertion loss: 0.75 db for high-performance cassettes and 0.50 db for premium-performance cassettes. This performance, which includes the loss of the rear panel MPO and front panel LC or SC connectors, represents an improvement over 1.25 db or 1.5 db for firstgeneration legacy cassettes. The combination of enhanced low-dmd fiber and improved cassette performance significantly increases flexibility in deploying a cabling system in a DC. With traditional OM3 LOMF and first-generation cassettes, achieving the channel insertion-loss budget over a full 300 meters was pushing the limits: the cable loss at 1.05 db and the insertion loss for 2 cassettes at 2.5 db produced a total loss of 3.55 db. This constrains the design flexibility. With improved fiber and cassettes, it is now possible (although not necessarily practical) to use as many as seven cassettes in the path. The extra system margin Two things need to be noted about Figure 5: 1. The improved fiber has an attenuation of 3.0 db/km (as opposed to 3.5 db/km for OM-3 fiber), which yields a loss of 0.9 db over 300 meters. 2. The graphic is for 300-meter channels. Most channels in DC applications are under 100 meters, which means additional power is reallocated to the budget. Figure 6 shows the distribution of real-world multi-fiber cable backbone lengths commonly used in the DC. Cable lengths over 25 meters are the exception: the vast majority of backbone cables are shorter. Figure 5. Low DMD cable and improved cassettes can allow more connections in the channel. Figure 6. Most backbone cables in a DC are much shorter than the 300 meters maximum allowed by standards and the 600 meters possible with such cables as the GIGAlite-XB. Copyright 2008 Berk-Tek, a Nexans Company and Ortronics/Legrand, All rights reserved.

It s the System That Counts The performance of a fiber-based cabling solution needs to be viewed at the system level and not just as an assembly of components. The newer high-performance and premium-performance fiber cassettes are perfect examples. Because the cassette s performance is primarily attributed to improved connector end-face polishing and connector end preparation at the factory, it is essential that the attached backbone cable and patch cords are prepared with the same high-quality process. Otherwise, the improved system-level insertion loss performance may not be realized. Simply put, to achieve improved performance you need high-performance or premium cassettes and matching cables. Similarly, to allow the ISI penalty to be reallocated to the channel budget, all fibers backbone, patch, and fiber internal to the cassette must use the improved high-performance, low-dmd cable. The example in Figure 5 is based on worst-case performance at 300 meters. For other channel lengths, the calculations can be easily modified. Such systems will easily accommodate longer channels with fewer cassettes or shorter channels with the potential of additional cassettes. The important consideration is that, by using worst-case maximum numbers, real-world typical performance will provide an additional comfortable margin. The increased flexibility in system configuration today translates to peace of mind knowing you will not be restricted tomorrow. The use of multi-fiber cable and cassettes, for example, will ease the transition to future parallel transmissions being considered for 40 Gb/s and 100 Gb/s systems now being defined. What s more, the easier installation, the simplified management, and the higher performance combine to offer a lower total cost of ownership. Conclusion Cassette/multi-fiber cabling systems in the DC have obvious advantages in space savings and simple installation. Low-DMD fiber, such as Berk-Tek s GIGAlite-XB, combined with improved connector performance in MOMENTUM 3 cassettes offer flexibility for longer runs or more connections. Gone are the severe limitations on the number of cassettes that you can use in a channel which opens up the widest range of cabling and equipment topologies to keep the growth and evolution of DCs fluid and easily managed. What to Look for in a Fiber Cassette Low Insertion Loss. The lower the insertion loss, the more cassettes that can be used in the channel and the greater flexibility you have in your DC topology Compatibility with Low-DMD Fibers. A cassette using low-dmd fiber is already compatible with systems using low-dmd fiber. This allows the ISI penalty to be reallocated to the channel insertion loss. Internal Fiber Management. The cassette should have internal guides to keep the fibers from bending too tightly. Comprehensive Performance Documentation Conveniently Displayed. The cassettes should be supplied with factory test results. Because such data is often misfiled, lost, or located inside the cassettes, Ortronics/Legrand now affixes the performance data to a label on the outside of the housing. Protected Array Connection. Many cassettes are designed so that the array connections stick out from the back of the cassette, increasing the chance they will be inadvertently bumped or damaged. Cassettes that have the connection located in a recess in the cassette housing provide better protection. Choice of patchcord connectors. The LC interface is the most popular (and recommended) because it allows the best combination of high-density, lowloss, and compatibility with equipment vendors. Some users may prefer other options, such as the SC or MT-RJ. Protected, recessed fiber array connection Convenient, accessible performance data Various adapter interface options up to 24 fibers Copyright 2008 Berk-Tek, a Nexans Company and Ortronics/Legrand, All rights reserved. 5

Berk-Tek, A Nexans Company 132 White Oak Road New Holland, PA 17557 Tel: 800-BERK-TEK; 717-354-6200 Fax: 717-354-7944 www.berktek.com Ortronics/Legrand 125 Eugene O Neill Drive New London, CT 06320 Tel: 800-934-5432; 860-445-3900 Fax: 860-405-2992 www.ortronics.com Copyright 2008 Berk-Tek, a Nexans Company and Ortronics/Legrand, All rights reserved. 6