Structural Lining for Water Mains. Presenters: Stephen Marcino, PE and Micah Blate, EIT (JMT)

Similar documents
Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

Introduction to Pressure Pipe Rehabilitation with CIPP

Water Main Lining A Sustainable Alternative to Open Cut Replacement

Rehabilitation or Replacement? That Is The Question

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

PRESSURE PIPE REHABILIATION CIPP TECHNOLOGIES

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

The Environmental Implications of Road Culvert Repair Technologies. Bridget Donaldson Senior Research Scientist

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

CURED-IN-PLACE PIPE MINIMIZING RISK BY DEFECT CODING

REHABILITATION OR REPLACEMENT? THAT IS THE QUESTION

Trenchless Technology for Drainage Structures

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

Culvert Rehabilitation Practices

THE ECOLOGICAL IMPLICATIONS OF TRENCHLESS PIPE REHABILITATION

Ultraviolet (UV) Light Cured Fiberglass Reinforced Cured-In-Place Pipe (CIPP) It is not just for sanitary sewer rehabilitation

CIPP for Large Diameter Pressure Pipes. Water Research Foundation Large Diameter Pipe Rehabilitation Seminar 20 January 2016 George Bontus, P.Eng.

02780 LINER FOR SEWER REHABILITATION

TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

The leader in trenchless rehabilitation

Summary 7/11/2012. Michigan Water Environment Association 2012 Annual Conference Boyne Mountain Resort

IS THAT LINER THICK ENOUGH?

SPR PE Steel Reinforced Liner

GENERAL SPECIFICATIONS AND GUIDELINES FOR INSTALLATION MASTERLINER CURED-IN-PLACE PIPE SYSTEMS

Trenchless Construction Technology and Issues

San Antonio, TX July 28, 2011

epros DrainLiner Program

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

APPLICATION OF GLASS-REINFORCED PLASTIC TO SEWER REHABILITATION

Section 2320 Cured-In-Place Pipe Lining

Section Four: Linings and Coatings

Pipe Bursting. Case Study at Zeeland, MI Collections Seminar September 6, Presentation Agenda. What is Pipe Bursting? What is Pipe Bursting?

PORTLAND BES ADVANCES IN SEWER MAINTENANCE AND REPAIRS BY OPERATING MULTIPLE CIPP CREWS.

ENGINEERING DESIGN GUIDE FOR REHABILITATION WITH CURED-IN-PLACE PIPE Second Edition

SECTION NONREINFORCED CONCRETE SEWER PIPE

Trouble Shooting for Trenchless Liner Installation During Sewer Line Rehabilitation

IN-SITU CULVERT REHABILITATION: SYNTHESIS STUDY AND FIELD EVALUATION

LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE POTABLE WATER DISTRIBUTION SYSTEM

EI- MH TO MH LINER

Sewer Pipe Lining An Economic Solution for Pipe Rehabilitation By Tawana Albany Nicholas, Virgin Islands Waste Management Authority

Demonstration of an Innovative Large-Diameter Sewer Rehabilitation Technology in Houston, Texas

Section SEWER PIPE INSTALLATION AND TESTING

SEKISUI SPR CONSTRUCTION PIPE SYSTEMS FOR THE NEXT GENERATIONS

12/8/2014. Brought To You By: This webcast is sponsored by NASSCO with the support of IPBA.

2. SOCIAL COSTS Introduction...19 Worldwide Experience and Best Practices in Mitigating Disruption..20

INSTALLATION OF INSITUFORM LINER

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

by Leonard Friesenhahn, P.E.

Large Bore Rectangular Box Culvert and Non Circular Rehabilitation with CIPP

CONSTRUCTION OF NON-CIRCULAR SEWER REHABILITATION PROJECTS IN LOS ANGELES

Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam

Annular Space Grouting of Slipline Products

Water Transmission & Sewer Force Main Renewal 16 through 60

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

Using StrongPIPE Hybrid FRP for PCCP Rehab in Miami-Dade System

Superior Pipe Restoration Solutions. Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com

Flowtite Jacking Pipe

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

BKP Berolina Polyester GmbH & Co. KG. Berolina-Liner System Lightspeed in gravity pipe rehabilitation!

CCTV PIPE INSPECTION AND EVALUATION RUNWAY 17L-35R

LIFELINE PIPELINE RESTORATION AND SEISMIC MITIGATION

TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe

ASTM C76, Class III, Wall B, except as modified herein. Clean natural sand, ASTM C33. Artificial or manufactured sand will not be permitted.

City of Lincoln, Nebraska STEVENS CREEK BASIN TRUNK SEWER TECHNICAL MEMORANDUM NO. 5 PIPE MATERIAL SELECTION TABLE OF CONTENTS

A SUPPLEMENT OF TRENCHLESS TECHNOLOGY PIPE PIPE RELINING

REHABILITATION OF FAILED CORRUGATED METAL PIPE SPILLWAYS PRESENTED AT JUNE 1996 REGIONAL CONFERENCE MID-ATLANTIC COUNCIL FOR SAFE DAMS

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

Sewer network renovation using glass-fiber reinforced (GRP) pipe liners

CHALLENGES IN LINING A 100 YR OLD BRICK SEWER

DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

REHABILITATION METHOD FOR INCREASING FLOW VELOCITY AND REDUCING SEDIMENTATION

Pressure Pipe and Sewer Renovation

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

Pipeline Replacement using Relining

Tremco Fire Protection Systems Group Technical Bulletin

STANDARD SANITARY SEWER REHABILITATION SPECIFICATIONS

Utilizing Trenchless Technology to Achieve Watermain Asset Management Objectives

Where life interacts with infrastructure.

Oil and Gas Pipeline Design, Maintenance and Repair

- GFRP pipe liners - UV curing technology - TQM - Total Quality Management

Transcription:

Structural Lining for Water Mains Presenters: Stephen Marcino, PE and Micah Blate, EIT (JMT) 2015 PA-AWWA Annual Conference Thursday, April 23 rd, 2015

Agenda 1. Introduction 2. Purpose of Lining 3. Lining History 1. Spray-on 2. CIPP 4. Classifications of Liners 5. Spray-on Structural Liners Example Manufacturers 6. Cured-in-Place Pipe Liners Example Manufacturers 7. Conclusion

Introduction Aging infrastructure Alternate to open-cut methodology Trenchless technology Limited resources and capital Structural Lining Less intrusive Potentially less Cost Two primary types: Spray-on Cured-in-place pipe (CIPP) Image provided by NY Times

Purpose of Lining Objectives of Lining may include: Improve water quality Stop water loss/leaks Structurally renew existing pipeline Improve hydraulic characteristics Extend service life of pipeline Reduce cost Image courtesy of Ellingson Companies

Lining History Spray-on Cement Mortar Lining First used in 1830s¹ Non-structural Structural Lining Epoxy implemented in UK in 1985 US approval in 2008 via ANSI/AWWA C620-07 Standard (Spray-applied in-situ epoxy lining) Image courtesy of Thortex (epoxy coating application) ¹According to Water Research Foundation (WRF)

Lining History CIPP CIPP¹ Pipe within a pipe First implemented in 1971 in London, named insit u form (Latin for form in place ) Originally felt tube saturated with resin Patent issued 1977 and commercialized by Insituform Technologies Patent expired in 1994 Image courtesy of GML Coatings, LLC ¹Artice: Evolution of Cured-in-Place Pipe Allows Structural Renewal of Drinking Water Pipe, David Kozman, PE

Classifications of Liners AWWA developed classification system to describe and differentiate among linings Class 1 Non-structural Coating/corrosion protection Class 2 Semi-structural pressure transferred to host pipe Requires adhesion to host pipe Class 3 Semi-structural pressure transferred to host pipe Does not require adhesion to host pipe Class 4 Fully-structural Independent of host pipe Pipe within a pipe

Spray-On Structural Liners

Spray-on Structural Liners Process Overview Pre-inspection Isolate segment Requires two access points Application rig pushed into position and winched backwards while nozzle head applies material to pipe Post-inspection Image courtesy of trenchless-pipelining

Spray-on Structural Liners Advantages Minimal effort to re-establish service connections Minimize disruptions to community due to minimal access pits compared to opencut Typical maintenance/repair methods can be applied to completed pipelines Limitations Voids and blisters may form if pipe is not properly prepared Potential for uneven liner due to rig issues Material can slump on invert of pipe Image courtesy of Municipal Sewer and Water Magazine

Spray-on Structural Liners Example Manufacturers Quest Inspar PipeArmor Installation sizes: 6 174 Inches (any pipe material) Material 100% Polyurea Installed by Quest Inspar >0.020 inch thickness Design standards: ASTM D-192 AWWA class IV designation (fully structural) Product Certifications: NSF/ANSI 61 Standard Service Connections: Service connections are not blocked during the lining process. Maximum lining distance: 900 LF in each direction (upstream/downstream) at one time Image courtesy of Quest Inspar

Spray-on Structural Liners Example Manufacturers 3M Skotchkote Renewal Liner 2400 Installation sizes: 4 24 Inches (DI and CI) Material 100% Polyurea Requires authorized applicator contractor 0.05 inch to 0.3 inch thickness Design Standards: ASTM F 1216-09, D638-08, D2990-08, and D1599-99 Non-designated fully structural lining (designed to operational pressure and external loads and conforming to above-referenced standards) Product Certifications: NSF/ANSI 61 Standard Service Connections: Service connections are not typically blocked during the lining process. If they are, a mechanical robot can reinstate them. Maximum lining distance: 600 LF at one time Image courtesy of 3M

CIPP Structural Liners

CIPP Structural Liners Process Overview Liner tube wetted-out with resin before inserted into host pipe Cured utilizing hot water, steam, or UV Advantages Minimum disturbance to community Line through bends and non-circular shapes (oval, elliptical, etc.) VOC free Disadvantages Like spray-on, bypass or isolation of line required Requires temperature monitoring of materials prior to installation Typically requires certified installers Image courtesy of Trenchless International

CIPP Liner Example Manufacturers Aqua Pipe Installation sizes: 6 24 Inches (CI, Steel, or DI) Materials, 3 layers: Outer Layer: Semi-Porous synthetic woven polyester (proprietary) Propriety resin Inside: Thermal Polyurethane Membrane Requires licensed installers. Licensing includes rigorous training and equipment purchase. Design Standards: ASTM F1216 and ASTM 1743 AWWA Class IV Designation Product Certifications: NSF/ANSI Standard 61, UL, NQ 3660-950, and WRAS¹¹ Approved Material Image courtesy of Aqua Pipe ¹ Water Regulations Advisory Scheme

CIPP Liner Example Manufacturers Aqua Pipe Installation: 1. The woven synthetic polyester jackets are impregnated on site, 2. The jacket is pulled in place through the host pipe. 3. Because the outer layer of the liner is semi-porous, the resin seems through it, allowing adhesion to the host pipe. 4. The final step includes circulating hot water through the pipe for curing purposes. Service Connections: Following installation a mechanical robot reinstates service laterals. Maximum Installation Length: 1,000 LF at one time Images courtesy of Aqua Pipe

CIPP Liner Example Manufacturers SEKISUI NordiPipe Installation sizes: 6 48 Inches Materials, 4 layers: PE Coating Needled Felt Glass Fiber Epoxy Resin Requires licensed installers. Licensing includes rigorous training and equipment purchase. Design Standards: ASTM D638, D790 AWWA Class IV Designation Product Certifications: NSF/ANSI 61 Standard Image courtesy of SEKISUI

CIPP Liner Example Manufacturers SEKISUI NordiPipe Installation: The liner is impregnated on site, in a climate controlled environment, with an epoxy resin. Once prepared, the liner is inverted into place and cured with steam or heated water. Service Connections: Following installation a mechanical robot reinstates service laterals. Maximum installation length: 500 LF at one time Images courtesy of SEKISUI

CIPP Liner Example Manufacturers Insituform InsituMain Installation sizes: 6 60 Inches (CI, DI, Steel, Cement, RCP, Plastic) Materials, 3 layers: Polyester Fiber Fiberglass Epoxy Resin Design Standards: ASTM F1216 and ASTM F1743 AWWA Class IV Designation Product Certifications: NSF/ANSI 61 Standard Image courtesy of Insituform

CIPP Liner Example Manufacturers Insituform InsituMain Installation: The composite material is impreganated on or off-site with an epoxy resin. The pipe is installed into the pipe with either an inverted or pull-in method (either direction). To cure the material, steam or heated water is circulated through the pipe. Service Connections: Following installation a mechanical robot reinstates service laterals. Maximum installation length: 1,500 LF at one time Image courtesy of Insituform

Conclusion and Summary Table Lining Method CIPP Lining Spray-on Lining Example Manufacturer SEKISUI Nordipipe (Class IV) Aqua-Pipe (Class IV) Insituform InsituMain (Class IV) 3m Skotchtite (Class III) Quest Inspar Pipe Armor (Class IV) Pipe Size (in.) Approximate Cost (Per LF)* 6 48 $100-$125 6 24 $105-$125 6 60 $120-$140 Materials Benefits Disadvantages Woven polyester and polyurethane Needled felt, glass fiber, epoxy resin Polyester fiber, fiberglass, epoxy resin 4 24 $125-$140 Polyurea 6 174 $120 135 Polyurea Fast installation Minimum surface disruption Minimum annular space between host pipe and liner (no grouting required) Increased Hazen-Williams C-factor VOC free Cost-effective Quick cure-time Little to no effort required for service connection reestablishment Minimal surface disturbance Cost-effective Typical maintenance/repair applicable following installation Certified installers not available in every area Internal pressure rating limitations Materials need to be monitored for temperature Bend limitations Limited number of installers/manufacturers Potentialdefects of liner due to applicator issues Material may slump in invert of pipe * Approximate installed costs for 6-inch pipe designed to a structural level. Costs can vary greatly depending upon specific site location, total length of pipe, condition of host pipe, installer, amount of bends and fittings and water service connections.

Questions?