Bridging the analytical gap



Similar documents
XFA 600 Thermal Diffusivity Thermal Conductivity

Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System

Differential Scanning Calorimetry DSC

DSC Differential Scanning Calorimeter

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

DMA-1 Direct Mercury Analyzer

Table of content. L81/RITA high speed Thermo Balance. Quattro Dilatometer. L75/1250/B/S Macro Dilatometer. New air cooled furnace program

SDT 2960 Simultaneous DSC-TGA including DTA capabilities

AMD Analysis & Technology AG

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Lecture 35: Atmosphere in Furnaces

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

MILESTONE H E L P I N G C H E M I S T S

Experiment #5: Qualitative Absorption Spectroscopy

MPA. Innovation with Integrity. Multi Purpose Analyzer FT-NIR

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

Elemental analyzer multi EA 5000

DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE. E. Günther, S. Hiebler, H. Mehling

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

Background Information

Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

HFM Heat Flow Meter Thermal Conductivity Analyzer

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

QGA Quantitative Gas Analyser

Characterization of Electronic Materials Using Thermal Analysis

13C NMR Spectroscopy

Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible

Performance and advantages of qnmr measurements

Physical & Chemical Properties. Properties

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Trace Gas Exchange Measurements with Standard Infrared Analyzers

Alkoxycarbonylation of Ethylene with Cellulose in Ionic Liquids

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

DETECTION OF COATINGS ON PAPER USING INFRA RED SPECTROSCOPY

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC

Pesticide Analysis by Mass Spectrometry

Advanced Solutions for Gas Monitoring

ß-CYCLODEXTRIN SYNONYMS

CATALYSIS & THERMAL ANALYSIS

Measurement & Analytics Measurement made easy

Characterization of Polymers Using TGA

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

TGA/SDTA851 e Module. Thermal Analysis. Technical data Quality Service

Analyzing Small Molecules by EI and GC-MS. July 2014

Thermal Diffusivity Thermal Conductivity

Features of the formation of hydrogen bonds in solutions of polysaccharides during their use in various industrial processes. V.Mank a, O.

How To Choose A Total Organic Carbon Analyzer

Chapter 2 Chemical and Physical Properties of Sulphur Dioxide and Sulphur Trioxide

MB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

Measurement of Specific Heat Capacity Using Differential Scanning Calorimeter

Spectral Measurement Solutions for Industry and Research

EL724. Biodegradable Resin Products [EL /2/ ]

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Fundamentals of Mass Flow Control

Thermo Scientific ConFlo IV Universal Interface

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

Thermal diffusivity and conductivity - an introduction to theory and practice

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Name Date Class CHAPTER 1 REVIEW. Answer the following questions in the space provided.

GCSE COMBINED SCIENCE: TRILOGY

AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Balancing chemical reaction equations (stoichiometry)

Supporting Information

Appendix 5 Overview of requirements in English

Determination of the heat storage capacity of PCM and PCM objects as a function of temperature

ORGANIC SAMPLE PREPARATION

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

SCION SQ Series GC-MS

Analytical Testing Services Commercial Price List ManTech International Corporation January 2016

Analysis of Phthalate Esters in Children's Toys Using GC-MS

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

Waters Core Chromatography Training (2 Days)

2.02 DETERMINATION OF THE FORMULA OF A COMPLEX BY SPECTROPHOTOMETRY

MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA

Department of Aerospace Engineering Indian Institute of Science Bangalore

Guidance for Industry

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Laboratory procedures in polymer chemistry

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

NMR and other Instrumental Techniques in Chemistry and the proposed National Curriculum.

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Expectations for GC-MS Lab

IB Chemistry. DP Chemistry Review

TRL-onlineTOC Monitor is designed for monitoring carbon content in

Safety data sheet according to 1907/2006/EC, Article 31

MATERIAL SAFETY DATA SHEET

Transcription:

Bridging the analytical gap Thermal analysis provides perfect tools for the characterization of all kinds of organic and inorganic solids or liquids. Thermodynamic transitions, thermal stability, decomposition and chemical reactions are detected and quantified with high accuracy in a broad temperature range. Information about the type and quantity of evolved gases, i.e. details about the chemistry behind the processes under study, are lacking in most experiments, however. The connection of thermal analysis with the powerful infrared spectroscopy for gas analysis bridges the analytical gap. A NETZSCH thermobalance (TG) is the general basis for couplings. The evolution of volatiles during a heating program is measured by corresponding weight changes down to a level of 0.01% of the sample weight. A purge gas flow carries the volatiles through a short heated transfer line to the gas cell of a BRUKER Fourier-Transform Infrared (FTIR) Spectrometer. All gases with a changing dipole moment are identified by their typical absorption spectrum and complex gas mixtures can be spectroscopically separated. Areas of application: - composition of materials - solid-gas reactions - combustion products - residual solvent content - precursor reactions - evaporation, outgassing

Optimized TG-FTIR coupling The TG-FTIR coupling designed through the joint efforts of BRUKER and NETZSCH engineers resulted in a real functional unit, both for the hardware and the software solution. An outstanding sensitivity for the gas analysis is provided due to low purge gas flow rates at the thermobalance, a natural, vertical gas flow around the sample, a heated furnace gas outlet, the shortest possible heated transfer line, and a beam-conforming stainless steel gas cell with a sensitive IR detector. This is supported by a comfortable integration between the Proteus software for thermal analysis and the OPUS software for the FTIR. All information is strongly correlated with temperature and time of the running experiment. Key features of the coupled TG-FTIR systems - excellent sensitivity - high resolution of superimposed effects - easy cleaning - complete system vacuum-tight - easy control from one PC FTIR gas cell (230 C) transfer line (250 C) optional MS coupling (300 C) adaptor (250 C) control thermocouple TG-FTIR coupling with heated adapter, transfer line and gas cell IR detector outlet water cooling TG cell motorized furnace cover micro furnace sample sample carrier

Application: Curing Powders and Paints Drying and curing of water based paint Volatile components in paints are of environmental issue during application. Water-based paints and powder coatings reduce this problem to a great extent. 31.9 mg of a two component hydro clear coat were analyzed in the TG 209 F1 Libra coupled to a TENSOR 27 FTIR spectrometer. The sample was heated at a rate of 5 K/min in a nitrogen flow of 45 ml/min up to 300 C. The main weight loss up to 100 C was clearly attributed to the water, but significant contributions come also from hydrocarbons, like alkyl acetates and aliphatic alcohols. The maximum evolution rate for these latter components is shown by the two peaks in the traces at 154 C. During drying of this clear coat, no indication of harmful or toxic volatiles was found. 3D display of paint spectra

Application: Medical drug products Stability, shelf life and residual solvents are important characteristics to study in drug substances, excipients and drug products. Acetylsalicylic acid (Aspirin ) Salicylic acid bp. 211 C at 1013 mbar Phenol bp. 181 C at 1013 mbar Decomposition scheme of acetylsalicylic acid Thermal decomposition of acetylsalicylic acid A piece of an Aspirin tablet was heated at a rate of 10 K/min in a nitrogen flow of 45 ml/min up to complete decomposition. The two main steps of weight loss contribute to the evolved gas mixture with mainly acetic acid, salicylic acid, phenol and carbon dioxide. The high boiling components are efficiently transferred through the heated transfer line to the gas cell and clearly detected by FTIR. The reaction and decomposition scheme is shown by the structural formulas. wave number TG signal temperature Coupling TG 209 F1 Libra - Tensor 27 with external gas cell 5

Application: Reduced pressure for high boiling products The detection of volatile products with boiling temperatures strongly exceeding the heating of the transfer line requires special care. The vacuum-tight design of the BRUKER- NETZSCH coupling system allows working at a reduced pressure. This way, the boiling temperature of volatile samples is also reduced to a range where the passage through the transfer line is without loss. It is possible to detect high boiling plasticizers in polymers and rubbers like Fomblin in a perfluorinated O-ring, tested below. At a pressure of 100 mbar in the thermobalance and the whole gas path, the plasticizer Fomblin which evolved from the O-ring was identified at 370 C by comparing with the spectrum for the pure substance. At higher temperatures (460 C), decompostion products of the polymer, like HF and other fragments at the marked absorption bands, are additionally detected. Detection of evolved gases during heating of a perfluorinated rubber at reduced pressure

Calibration + Quantification TG-DTG and Gram-Schmidt plot with 4 calibration peaks and a sample peak for CO 2 evolution from CaCO 3 The unique PulseTA is based on the injection of a specific amount of gas or liquid into the purge gas flow and monitoring of the changes of sample mass, enthalpy and evolved gases. PulseTA offers three principal means of thermoanalyitcal study, depending on the kind of injected gas or liquid: Injection of an inert gas which does not interact with the sample Because the amount of injected gas is known, this mode can be used for a precise calibration of the coupled TG-FTIR for quantitative gas analysis and it increases the sensitivity for detection of volatile contents even below 0.01%. Injection of a gas which chemically reacts with the sample This mode provides the opportunity of investigating all types of solid-gas reactions at incremental reaction extents (e.g. catalyst research). Injection of a gas which adsorbs at the sample surface This mode offers the means to study adsorption / desorption phenomena at atmospheric pressure and at specific temperature. 3D plot for CO 2 pulses and CaCO 3 decomposition

Application: Building materials Energy-saving in building requires wall constructions with low thermal conductivity. This is achieved using building bricks with high porosity. Various organic products capable of producing a high volume of voids are mixed into the clay to form the cavities during firing. The burn-out of the organics in a traditional clay brick is accompanied by high energy release (775 J/g). Water and carbon dioxide are the main volatiles during the binder burn-out, but the FTIR also clearly detects the evolution of HF and SO 2 from the clay. The identification of the emissions allows the optimization of the firing process from economical and ecological viewpoints. TG signal Weight and energetic changes of a raw clay for porous bricks wave number

Training, Application service, Contract testing Short start-up time, efficient use of new coupled instruments and helping our customers interpret results are goals of our after-sales support teams. Learn from our experience and that of our users in special training courses and users meetings, while visiting our well equipped application laboratories, or during hands-on workshops. Enjoy your travel in beautiful regions when visiting BRUKER Optik GmbH in Ettlingen or NETZSCH- Gerätebau GmbH in Selb, Germany. If an investment in a coupled instrument from BRUKER or from NETZSCH is currently not in your horizon, please allow us to offer you our excellent testing services for all your sampling needs. Special coupling seminar temperature 3D plot for gas evolution during brick firing

Software OPUS for comprehensive FTIR measurements & evaluations The OPUS user interface offers many features for displaying and managing infrared spectra. Customizable pop-up menus and tool bars allow users to configure the OPUS software to their applications. The OPUS / CHROM software provides special routines for setting up experiments and performing evaluations for the hyphenated techniques, especially TG-FTIR. Both the integral Gram-Schmidt chromatogram trace and spectral windows traces for interesting absorption bands can be calculated and displayed in real time. spectra. All manipulations and evaluation functions offered in the OPUS software can be applied to the 3D. The OPUS / SEARCH package contains an extensive array of search functions in addition to a full featured library editior. The search software can be used with a large set of commercial libraries or create and maintain user own libraries. The OPUS / 3D is a package for processing and viewing results obtained with the OPUS / CHROM. It supports 2D and 3D representations of the data together with TG and time data. It also allows 3D files to be created from individual Screen dump: spectra of paint measurement and evaluation Screen dump: multi-window spectra evaluation

A Single operating software Proteus for Thermal Analysis Integration with OPUS / CHROM The control of measurements with TG-FTIR instruments is governed by the Proteus software. The user gives the command for data acquisition, once both the OPUS and the Proteus software have had the parameters inputted. The online data collection is simultaneous and synchronized so that later, during evaluation, a precise time and temperature correlation between all the signals from the two coupled analytical systems is guaranteed. The user works with the two software packages on one computer and has all possibilities of evaluating data and displaying results in the OPUS and in the Proteus software according to his preferences. The integration of the two software packages based on effective data exchange from acquisition to evaluation makes the coupled TG-FTIR a real functional unity. Special TA-FTIR features: - simultaneous TG-DSC/DTA-FTIR instrument control and data storage on the same PC - combined analysis graphics of TG-DSC/DTA and FTIR signals - trace calculations with evaluation of characteristic temperatures and peak areas together with TG and DSC curves - Gram-Schmidt plot with temperature and peak area calculation together with TA curves Evaluation of CaCO 4 H 2 O decomposition

Versatility in couplings Why just coupling FTIR? Many reasons favor the infrared spectroscopy for the analysis of volatile products during thermal analysis on organics, polymers, rubbers, paints, biomaterials, drugs and food. But why not using additionally and even simultaneously a mass spectrometer to get information on all evolved species? Ask for our well proven solutions for simultaneous TG-FTIR-MS couplings. Or are you looking for state of the art solutions for mass spectrometer couplings and for GC-MS couplings? Let us show and demonstrate you our proposals, based on more than 30 years of experience in the field of coupling gas analysis methods. BRUKER entered the field of FTIR spectroscopy in 1974. The early instruments set new standards in research FTIR with evacuable optics, high resolution and automatic range change. Since then, the product line has been continuously expanding with instruments suitable for both analytical and research applications with exceptional performance characteristics. BRUKER led the way establishing FT-Raman as a major new analytical technique in the late 1980s. The recent introduction of dedicated FT Near IR systems for QA/QC has enhanced the reputation of BRUKER Optics as a leading supplier of FTIR and FT-Raman instrumentation. BRUKER Optics Inc. has R&D and manfacturing centers in Germany and in the USA, supporting technical centers and offices throughout Europe, North and South America and Asia. BRUKER OPTIK GmbH Rudolf-Plank-Str. 27 76275 Ettlingen Germany Phone: +49 7243 504-600 Fax: +49 7243 504-698 E-mail: info@brukeroptics.de www.brukeroptics.de NETZSCH-Gerätebau GmbH offers a complete product line for the thermoanalytical and thermophysical characterization of materials within the scope of research, development and quality control. DSC, DTA, TG, STA, DMA, DEA, TMA, dilatometers and instruments for thermal conductivity and diffusivity form the core of the production program developed since 1953. We provide instruments for measurements in the extremely broad temperature range from -260 C to 2800 C, various couplings for FTIR and mass spectrometers, as well as a host of accessories for applications in research, development and quality assurance. Our well-equipped applications laboratories around the world are at your service for consultation or on a contract basis to demonstrate the excellent capabilities of our instruments. NETZSCH-Gerätebau GmbH Wittelsbacherstr. 42 95100 Selb Germany Phone: +49 9287 881-0 Fax: +49 9287 881-505 E-mail: at@netzsch.com www.netzsch.com NGB TG-FTIR E 500 0412 LH