Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets



Similar documents
Sliding and Folding Door Fittings Sliding Door Accessories

SSG PRODUCTS FOR SHIPS AND OFFSHORE

AMS 120. EFT Guest Card Terminal & Refund unit

STORAGE DESIGN LIMITED

Guide rail bracket (for adjustable heads)

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Furniture Fittings Furniture Handles and Knobs

Huwilift DUO, Huwilift DUO Forte Seite 4 3. Huwilift MAXI. Huwilift MAXI UP. Huwilift Senso, Huwilift E-Senso Page 4 17

Installation Instructions and Ordering Information

Decorative Metal Wiring Accessories in Assorted Plate Finishes

Mini USB and USB 2.0-IP67 Connector System

InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley

BB-18 Black Body High Vacuum System Technical Description

PB accessories. PB accessories. Labelling option. Order Information B Printed board handle A BZA42727 BZA42724.

InForm Tables and Base Cabinets

Edition Perfect combination ratiopacpro Electronic P Edition kaging www clear order..biz information in the catalogue

Rack Cabinets. Rack Configuration. 19 inch

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

How you select and where to install me! Kitchen BE CAREFUL OF FOLLOWING PARAMETERS : A- Plumbing space needed (specifically the height).

swimming pool accessories

ADC Structured Cabling Solutions

Slides and Drawers. The right collection

ELECTRICAL CONNECTORS

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Colonnade Security Pipe

PRODUCT DATA SHEET T-LIFT DESK

Saferand easierinstallation

K17.11 DOOR BOLTS K17 DOORS

Fixturing systems Fixturing systems for measurement technology

Medical Lighting. XL4 Patient Light

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Interior Pocket Door System. A hiding gliding sliding door

mechanics PP-Profiles Panel Profiles PT-Profiles T-Groove Plates RE-Profiles Rectangular Profiles PU-Profiles Universal Profiles

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

1. Geo Vertical 2. Geo Horizontal

TARIFF CODE and updates standard

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

The space saving solution.

Batibox TM flush-mounting boxes for dry partitions

Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to

K17.12 Door closers K17. Doors

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

How To Buy A Designo Grille

Slimline Plus. Catalogue No. R6

Data Centre Solutions

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

SERVER ROOM CABINET INSTALLATION CONCEPTS

19" Open Rack for Network and Cabling Management

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

06 / Optional components. MAXDATA PLATINUM Server-Rack PLATINUM. [Product Guide]

Relay mounting systems

REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional

H45 LED - Direct and indirect pendant

Contractors Guide Central Inverter System Installation

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

PART-II (COMMERCIAL / PRICE BID) DESIGN, SUPPLY AND INSTALLATION OF CUSTOMIZED STEEL LAB FURNITURE.AT N.C.C.S., PUNE

New Media Power Socket Outlets. New Media Power Socket Outlets

CI/SfB. (31.59) X NOVEMBER 2003 Coburn Interior Sliding Systems

PHA 2000 PHB 3000 EXIT PAD

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

ASR Emitter I und Emitter I Exclusive

LIEBERT VNSA Installation Sheet

Workspace and storage furnishings

1. Taboe Sani 2. Taboe 3. Taboe Freestanding

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

QUICK BUILD DEMOUNTABLE CONTAINERS & WAREHOUSES. Construct the Quick-Build Container in under 5 minutes!

Cable entry plate KDP

HARTING Ethernet Cabling 4-poles Overview

Product Information 19 / 45HU Data-Center-Rack (Cabinet)

HARTING Ethernet Cabling 4-poles Overview

Linkeo 19" freestanding cabinets

Integral Kit Instructions

No Phone Line II-48 System

LABORATORY CASEWORK. Table of Contents. Laboratory Cabinetry and Specialties. ADVANTAGE laboratory. Series/Model Number Specification...

TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150

Morgue refrigeration unit

The Solution for Flexible Workspace Electrification WHERE TO PUT THE SOCKETS? ANYWHERE.

VOYAGER 570G. 744A Sprayer Control

Motorhome Entrance Door CaraD-RF With Aluminium Door Panel Art. 1401

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s

Surface Water Drainage Products

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

1.1 DIMENSIONS AND WEIGHT PAG LOAD CENTRE FOR LIFTING PAG STORAGE CONDITIONS PAG. 2

installation guide ACTIV-1

SIMULATION PRE-INSTALLATION GUIDELINES CONTRACTOR REQUIREMENTS FOR ROOM PREPARATION

UNIVERSAL RAILING, STEEL

Select Radiators Installation Guide

Rack installation instructions

ARCHITECTURAL. FritsJurgens Pivot Door System Product Range Brochure

Ethernet Cat 5e & Cat 6 Patch Panels

HDA

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

BLADE S-MAX Cabinet for Blade Server

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Transcription:

Complete underfloor box for one Modul 45 socket and two data connection sockets Screed height 105-165 mm In the field of complete service outlets, the GE 1 and GET 1 models are a universal, high-quality solution. The GE 1 version has a cord outlet for dry-cleaned floors, whilst the GET 1 has a tube body for wet-cleaned floors. Both types have a solid aluminium lid and are equipped with a stainless steel housing. A Modul 45 Schuko socket can be installed as a power supply, and there are also two empty slots for data technology or telecommunications systems modules (cooperation with R&M, see data technology section). System components Square GE1 boxes with cord outlet and GET1 with tube body Irrespective of screed type Flexible insertion The combi box The side mesh can be used universally. Use in cement and liquid screed is possible. The pipes and cables can be inserted without difficulty as the mesh of the underfloor connection box can be processed using scissors or a knife. Major benefits through small size and combined use as power supply and optional network connection. 174 UFS

Type GE 1 VA Length Width Screed height mm mm mm 125 125 105-165 Complete, pre-mounted underfloor box with flexible mesh apron for equipment with one power socket of the Modul 45 series and two R&M RJ45 data connection sockets. Version for drycleaned floors, with solid aluminium lid and cord outlet. GE1 Service outlet, complete with cord outlet Material symbol pcs kg/% pc V2A V2A 1 215,000 7368 38 7 Type Length Width Screed height GET1 Service outlet, complete with tube body Material symbol mm mm mm pcs kg/% pc V2A GET 1 VA 125 125 105-165 V2A 1 205,000 7368 39 0 Complete, pre-mounted underfloor box with flexible mesh apron for equipment with one power socket of the Modul 45 series and two R&M RJ45 data connection sockets. Version for wetcleaned floors, with solid aluminium lid and tube body. Type pcs kg/% pc SGH 50 1 3,700 7368 59 3 For opening the GET1 service outlets. Suitable for all service outlets and tube bodies with a smooth surface. Suction lifter UFS 175

Service outlets with power socket Surfaces Version Material Socket Nickel-plated, old brass, old copper, chromeplated With protection frame or with contact frame Die-cast zinc Power socket, British Standard, switched The round GESRM2 service outlet is a prefitted installation unit. The scope of delivery contains a power socket. The metallic installation unit can be supplied in four colour tones: nickel, chrome, old copper and old brass. Two versions are available for use in screed floors: with guide frame and with protective frame. The version with the protective frame is used for raised floors. When closed, the installation unit can be wet-cleaned. The minimum installation depth is 70 mm. System components Service outlet, underfloor outlet box Mounting in underfloor outlet boxes Mounting in underfloor boxes Prefabricated mounting The UDL2-120 outlet box must be fully in contact with the raw floor and be flush with the top edge of the screed. The UZD..RM2 mounting lids are required for installation in an underfloor box. After work on the floor covering has been completed, the installation unit is screwed into the installation openings, and is then aligned and fixed. Then the socket is connected or the optional expansion takes place with data technology connection systems. 176 UFS

Complete mounting lid closed The lid of the service unit does not possess a recess for the insertion of floor coverings. It is smooth and is flush with the protection frame or the contact frame. GESRM2 Complete service outlet with protection frame for UZD/UDL pcs kg/% pc Zn / N GESRN2USBBSS nickel-plated 1 81,900 7428 01 2 Round service outlet with prefitted single-gang power socket, switched (BS-type). The service outlet has a floor covering protection frame and can be used in combination with an underfloor box UZD or an underfloor outlet box UDL2-120. The minimum installation depth is 70 mm. Surface: nickel plated. pcs kg/% pc Zn / CuZn GESRMS2USBBSS brass-coated 1 81,900 7428 01 6 Round service outlet with prefitted single-gang power socket, switched (BS-type). The service outlet has a floor covering protection frame and can be used in combination with an underfloor box UZD or an underfloor outlet box UDL2-120. The minimum installation depth is 70 mm. Surface: old brass. pcs kg/% pc Zn / Cu GESRK2USBBSS copper-plated 1 81,900 7428 01 0 Round service outlet with prefitted single-gang power socket, switched (BS-type). The service outlet has a floor covering protection frame and can be used in combination with an underfloor box UZD or an underfloor outlet box UDL2-120. The minimum installation depth is 70 mm. Surface: old copper. pcs kg/% pc Zn GESRC2USBBSS chrome-plated 1 81,900 7428 01 4 Round service outlet with prefitted single-gang power socket, switched (BS-type). The service outlet has a floor covering protection frame and can be used in combination with an underfloor box UZD or an underfloor outlet box UDL2-120. The minimum installation depth is 70 mm. Surface: chrome plated. UFS 177

GESRM2 Complete service outlet with protection frame for UZD/UDL pcs kg/% pc Zn GESRSM2USBBSS matt 1 81,900 7428 01 8 Round service outlet with single socket with switch (BS). This version has a floor covering protection frame and can be installed flush with the surface in conjunction with a UZD underfloor junction and branch box or a UDL2-120 connection box in screed floors. The minimum installation depth is 70 mm. Surface: matt, black chrome-plated. GESRM2 Complete service outlet with protection frame for RF/CF pcs kg/% pc Zn / N GESRN2HSBSS nickel-plated 1 103,700 7428 03 2 frame and can be installed in false and cavity floors. The minimum installation depth is 70 mm. Surface: nickel-plated. pcs kg/% pc Zn / CuZn GESRMS2HSBSS brass-coated 1 103,700 7428 03 6 frame and can be installed in false and cavity floors. The minimum installation depth is 70 mm. Surface: brass. pcs kg/% pc Zn / Cu GESRK2HSBSS copper-plated 1 103,700 7428 03 0 frame and can be installed in false and cavity floors. The minimum installation depth is 70 mm. Surface: old copper pcs kg/% pc Zn GESRC2HSBSS chrome-plated 1 103,700 7428 03 4 frame and can be installed in false and cavity floors. The minimum installation depth is 70 mm. Surface: chrome-plated. pcs kg/% pc Zn GESRSM2HSBSS matt 1 103,700 7428 03 8 frame and can be installed in false and cavity floors. The minimum installation depth is 70 mm. Surface: matt, black chrome-plated. 178 UFS

frame and can be installed flush with the surface in conjunction with a UZD underfloor junction and branch box or a UDL2-120 connection box. The minimum installation depth is 70 mm. Surface: nickel-plated. GESRM2 Complete service outlet with floor covering contact frame for UZD/UDL GESRN2UABBS pcs kg/% pc Zn / N nickel-plated 1 74,900 7428 02 2 pcs kg/% pc Zn / CuZn GESRMS2UABBS brass-coated 1 74,900 7428 02 6 frame and can be installed flush with the surface in conjunction with a UZD underfloor junction and branch box or a UDL2-120 connection box. The minimum installation depth is 70 mm. Surface: brass. pcs kg/% pc Zn GESRK2UABBS copper-plated 1 74,900 7428 02 0 frame and can be installed flush with the surface in conjunction with a UZD underfloor junction and branch box or a UDL2-120 connection box. The minimum installation depth is 70 mm. Surface: old copper. pcs kg/% pc Zn GESRC2UABBS chrome-plated 1 74,900 7428 02 4 frame and can be installed flush with the surface in conjunction with a UZD underfloor junction and branch box or a UDL2-120 connection box. The minimum installation depth is 70 mm. Surface: chrome-plated. pcs kg/% pc Zn GESRSM2UABBS matt 1 74,900 7428 02 8 frame and can be installed flush with the surface in conjunction with a UZD underfloor junction and branch box or a UDL2-120 connection box. The minimum installation depth is 70 mm. Surface: matt, black chrome-plated. UFS 179

Underfloor outlet box UDL2-120 Type Screed height mm pcs kg/% pc ST / FS UDL2-120/70 70+15 1 77,200 7408 55 8 UDL2-120/80 80+15 1 82,610 7408 56 2 Underfloor outlet box for the installation of a GESRM2 service outlet. With 2 x 2 openings for M20 or Pg16 pipe installation. Mounting plates Type pcs kg/% pc ST / FS MPR2/2LJU6C 1 30,000 7407 62 1 For the installation of two data modules of the type LJU6C in service outlet GESRM2. Dimension of the assembly opening in mm: 36,2 x 22. 180 UFS

Complete service outlet with underfloor box for conduit installations, 2 compartments Size Material Minimum installation depth For 2 compartments V2A, brass 95 mm The design of the square UDHome4 installation unit is very compact. Just one order number contains all the parts required for both mounting and use. The parts visible in the floor covering are made of V2A or brass. The installation unit permits the installation of electrical resources in dry-cleaned cavity floors or in screed floors. As only conduits can be used for cable routing, it can be installed anywhere in the floor, even outside an existing underfloor system, and is thus extremely suited for private living accommodation. The load capacity is designed for the requirements of office and administrative buildings. The floor structure must be at least 95 mm thick. System components UDHome4 Insertion of installation tubes Height adjustment of the UDHome4 Prefabricated mounting Breakable openings (front side on the two opposing sides and on floor plate) allow cable routing via the installation tube (M25). The minimum installation depth is 95 mm (measured from the raw screed to the top edge of the screed). The installation unit possesses four interior stable support brackets with a height-adjustment area of up to 30 mm and can thus be adjusted to the level of the ed floor. The cassette is designed with a 3 mm sheet steel plate and can accept floor coverings with thicknesses of up to 15 mm. The cassette can be opened using a handle in the cord outlet. UFS 181

UDHome4 Service outlet Type UDHOME4V Screed height mm 95-125 Material symbol pcs kg/% pc V2A V2A 1 345,200 7427 10 3 CuZn Square installation unit for use in dry-cleaned cavity floors and in dry-cleaned screed floors. The housing has pre knock-outs for conduits (M25). Top frame height levellable to final floor level with 4 levelling units. Minimun installation depth is 95 mm, levelling range is + 30 mm. UDHOME4M 95-125 CuZn 1 355,200 7427 10 7 Mounting support, nominal size 4, for APMT2 cover plates Type pcs kg/% pc ST / FS MT4R4AP2 1 12,310 7407 74 8 Mounting support for accepting APMT2 cover plates, which aid the installation of accessories in installation units of nominal sizes 4 and R4. Cover plate APMT2/0 Type Colour Length mm pcs kg/% pc ST / FSO APMT2/0 grey/white RAL 9002 163 80 12,300 7406 91 2 For blank covering of an unused compartment in an international mounting support. L = 163 mm. Cover plate APMT2/1 Type Colour Length mm pcs kg/% pc ST / FSO APMT2/1 grey/white RAL 9002 163 40 7,600 7406 91 6 Cover plate for installing four data connection sockets of type LJC6C. L = 163 mm. 182 UFS

Type Colour APMT2/2 grey/white RAL 9002 Cover plate for installation of a double BS socket, type MK14347D1WHI. L = 163 mm. Length mm pcs kg/% pc ST / FSO 163 80 8,100 7406 92 0 Cover plate APMT2/2 UFS 183