FIX TURE CARRI ERS. 140(a) MPB-2011-USA



Similar documents
Carriers, Fixtures & Piping

SECTION COMMERCIAL PLUMBING FIXTURES

PUBLIC RESTROOMS, DESIGN INTENT

Base Cabinet with Self-storing Folding Doors and Floor

WATER CLOSET SUPPORTS TECHNICAL DATA

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Packaged Terminal Air Conditioner Wall Sleeve Installation

Residential Plumbing BCN 1058

INSTALLATION INSTRUCTIONS

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Saferand easierinstallation

Installation Instructions

March 14, Installation of Bay, Bow and Garden Windows

SECTION SOIL AND WASTE SYSTEMS

SECTION 6. Glass Storefront Doors:

604 Water Closets and Toilet Compartments

Select Radiators Installation Guide

A. General: comply with appropriate standards. 1. International Association of Plumbing and Mechanical Officials: IAPMO. 2. California State AB 1953.

F1000 VITREOUS CHINA URINAL BENEFITS FEATURES

Top 10+ Mistakes of DWV plumbing design

Quartz Top Installation Instructions See separate installation instructions for installing your new Vanity.

AZEK Rail Install Guide

PART 1 GENERAL 1.1 SECTION INCLUDES

DE Frame with C Series Sidelight

Electrical Wiring Technical Bulletin

INSTALLATION OF A BAY WINDOW

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB

SECTION STORM DRAINAGE SYSTEM

Installation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls

Premier & Deluxe 3-Season Room Sliding Glass Door

Window Installation Instructions

PANELIZED HOME INSTALLATION GUIDELINE

RadianceRail Installation Guide

Sliding Door Hardware Installation Instructions

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

How To Fit A Portman Door Leaf

Guidelines for Earthquake Bracing of Residential Water Heaters

Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN

How To Install A Watertight Tub Drain On A Waterproof Waterproof Tub

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

DRAIN, WASTE AND VENT PLUMBING

Heavy Glass Frameless Shower Door With Return Panel

Clad Direct Glaze Window Installation Instructions

Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.

ADA Design Guide Washrooms & Showers

INSTALLATION INSTRUCTIONS

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

James M. Pleasants Company

TRANS-05, Torque Tube Removal, Rebuilding, and Installation

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

Slide the new steering column shaft through the steering column from the driver compartment.

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

Steel Door Frame Installation in Steel Stud Construction

B. Select combinations of fixtures and trim and other components that are compatible.

GENERAL PLUMBING REQUIREMENTS

Installation Guide. Bath and Wall Surrounds SERIES B

SECTION FACILITY STORM DRAINAGE PIPING

Installation Instructions

Can you design a frameless shower enclosure that doesn't leak?

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

CLEAR-DIVISIONS CENTERFOLD

Installation Instructions

Guidelines for Earthquake Bracing Residential Water Heaters

HOW TO MEASURE FOR DRAPERY & WINDOW

Mechanical Services Standard Specification Compressed Air Systems. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

Lathe Milling Attachment

Installation Instructions For Slider Casement Air Conditioners

LACAVA. Table of Contents. Owner s Manual. Wall-mounted & Vessel Sinks PS#:

Chapter 10 - Scaffolding Systems

OPERATING INSTRUCTIONS AND PARTS LIST FOR U U UNDERGROUND HOSE REELS

CLEAR-DIVISIONS VARIOFOLD

Chapter 3 Pre-Installation, Foundations and Piers

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

CLEANOUT FEATURES. KLEENATRON II Features CLEANOUTS

Part #20195 WORKBENCH BRACKET SYSTEM INSTRUCTIONS

glass & Glazing Products

Installation Instructions / Warranty

Installation Instructions

HORIZONTAL INSTALLATION

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

TYPE E Main Valve Sizes 3 /8 through 12

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base

Installation Instructions

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation Instructions

SPIRAL STAIR KIT INSTALLATION MANUAL

SLACK PERFORMANCE KARTS

K17.11 DOOR BOLTS K17 DOORS

1500 Follow Spot Yoke

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Installation Instructions

Transcription:

FIXTURE CARRIERS STRUCTURAL FEET The feet are heavy duty cast ductile iron and invertible. No distinction is necessary between right and left hand. Each foot wraps around the specially formed edge of the carrier body extending only 7/8" (22) beyond the faceplate. This wrap around design allows for better seating with a continuous adjustment slot that covers the full mounting range. Slots at the top and bottom provide additional means to install the feet. The 18" (460) height covers most mounting requirements for both standard and ADA water closets. CARRIER FACEPLATE The faceplate is lacquered cast iron, heavy duty and invertible for use with siphon jet or blowout water closets. Breakaway tabs and elongated mounting slots accommodate the full range of standard and wheelchair roughing-in heights. It slides into the groove in the structural feet to form a rigid assembly. FIX TURE CARRI ERS EXTENSION The extension includes a test cap and N.P.T. (tapered) threads. It is made of ABS plastic. The standard length is 8" (200) long and covers a 1" (25) minimum to 6 1/4" (160) maximum range. After system testing, the extension is easily cut off to meet the installation requirements. HARDWARE OPTIONAL ANCHOR FOOT The hardware is cadmium The anchor foot is heavy-duty plated, with chrome plated lacquered cast iron, which provides MIFAB cap nuts. three-point support. Adjustable FITTING GASKET threaded rod attaches the foot to the The gasket is elastomer and is fitting. A single anchor bolt secures the designed with a raised bead to provide foot to the floor. (Specify suffix -3) a positive watertight seal between the fitting and carrier body. It is held in place at the fitting opening, eliminating awkward handling when attaching the carrier body to the fitting. 140(a)

Fixture Carrier Selection Guide ADVANTAGES OF OFF-THE-FLOOR PLUMBING FIXTURES Off-the-floor plumbing fixtures are easily the most widely used plumbing fixture in commercial building today. As the name implies, no part of the fixture touches the floor of the installation. The fixture is mounted to steel studs protruding through the wall from a carrier support in the pipe chase. This carrier support is anchored to the chase floor and receives the fixture load. The advantages of off-the-floor fixtures, as opposed to floor mounted fixtures, are numerous. The most obvious advantages - installation, maintenance, sanitation and aesthetics - are presented here. TYPES OF WATER CLOSETS There are two types of water closets commonly used in commercial installations: siphon jet and blowout. The MIFAB closet carrier can be used to mount either type. SIPHON JET WATER CLOSETS use siphonic flushing action to evacuate the bowl. This is a quiet and economical type of flushing action that provides quick, efficient results. The large water surface area of the bowl, for better sanitation, is another desirable feature of the siphon jet water closet. The siphon jet closet mounts to the carrier with four mounting studs. RS FI URE C ARR IE 1. INSTALLATION The installation of floor mounted fixtures can be costly and time-consuming to the job. Floor mounted fixtures require slab penetration and sleeving at each location. The resulting waste piping is run under the slab, thus creating a need in multi-story buildings to provide a false ceiling for concealment purposes. The piping assembly also requires special consideration as it is usually accomplished piece by piece during installation. By comparison, the off-thefloor fixture installation does not involve slab penetration in the toilet room. Since all piping is behind the wall, there is no need for ceiling modification. And off-the-floor support systems are fairly modular in design, allowing for prefabrication, on or off site, before installation. All this contributes to substantial savings in time and cost. 2. MAINTENANCE Both floor mounted and off-the-floor plumbing installations may have similar mechanical service requirements; however, due to their inherent characteristics, the off-the-floor installations are generally considered easier to service and maintain. 3. SANITATION The most important consideration of toilet room design is sanitation, the ability to maintain a clean environment. The floor mounted fixture installation directly opposes this consideration. The base of the fixture magnetically attracts dirt that is difficult, if not impossible, to remove. Floor deterioration in the area of fixture contact also contributes to unsanitary conditions. The clearance that the off-the-floor fixture installation provides immediately resolves the problems of floor mounted design. Complete sanitation is easily maintained with normal cleaning. BLOWOUT WATER CLOSETS use a direct jet stream for bowl evacuation. This type of flushing action is rapid and forceful and primarily used in heavy duty installations such as stadiums and terminals. Due to this powerful flushing, the blowout water closet is noisier in operation than the siphon jet. The blowout closet mounts to the wall with three mounting studs. NOTE: It is highly unadvisable to mount Blow-out type water closets in a "Back to Back" type installation. 140(b) 4. AESTHETICS Aesthetic appeal is an important consideration in deciding upon fixtures. The clean, smooth lines of off-the-floor fixtures complement today's contemporary toilet room designs.

Fixture Carrier Selection Guide (Cont d.) FIXTURE CARRIERS PLATE TYPE CARRIERS The MIFAB plate type floor mounted fixture carriers have been developed to accommodate the majority of hanger plate supported fixtures such as urinals, plate type lavatories and water coolers for support independent of the wall. The MIFAB universal backing plate provides adjustment for a wide variety of fixtures from most manufacturers. MC-32 BACK OF SUPPORT BRACKET 2-1/2 (63) FRONT OF SUPPORTING PLATE CLIP HANGAR SUPPORT STUDS CONCEALED ARM CARRIERS MIFAB concealed arm lavatory carriers can be used with any lavatory fixture that has been drilled for concealed arm supports. This concealed arm support consists of ductile iron arms with leveling and locking hardware. These arm assemblies are available in two lengths to accommodate standard and wheelchair fixtures. After carrier installation and completion of wall construction, final adjustment can be made to the arm and sleeve assembly. Then the fixture is slid over the arms. Level and locking are accomplished through openings in the fixture itself. Installation is then complete. MC-41 INVERTIBLE HEADERS - are heavy duty cast iron and can be installed on either side of the ver tical upright. SINGLE UNIVERSAL PLATE ASSEMBLY FOR FIXTURE HANGER SUPPORT (SPECIFY MC-31) CLIP HANGAR SUPPLIED WITH FIXTURE BY OTHERS BEARING PLATE WITH STUDS EXTRA HEAVY RECTANGULAR STEEL STRUCTURAL UPRIGHTS (2 x 1 x 1/8 THICK) (50 x 25 x 3) BEARING STUDS NOT ATTACHED TO FIXTURE 42 (1050) RECTANGULAR STRUCTURAL UPRIGHTS - are heavy duty structural steel with integral welded feet and narrow in design to provide strong suppor t in drywall construction. (2 x 1 x 1/8 THICK) (50 x 25 x 3) FIX TURE CARRI ERS 3 (75) HEAVY DUTY INTEGRAL FOOT SUPPORTS 4-1/2 (113) FOOT SUPPORTS SHOULD BE SECURELY ANCHORED TO FLOOR WITH 1/2 (13) LAG BOLTS AND ANCHORS BY OTHERS Carriers are provided with complete installation instructions for customer convenience. DUCTILE IRON ARMS with levelling screws attached allow any lavatory to be easily positioned and leveled on the job. Locking devices, also attached to the arms, hold the fixture securely in place. Adjustable sleeves accommodate varying wall thickness. Due to accessibility of the adjustable sleeve set screws, final positioning of the arms from the wall can be made after wall construction is complete. CONCEALED ARM INSTALLATION DETAIL 140(c)

Fixture Carrier Suggested Specifications WALL HUNG CLOSET CARRIERS Wall Hung Water Closets shall be supported independently of the wall by MIFAB Series MC-1(*) carrier fittings with ductile iron adjustable foot supports. Where space permits, waste piping shall be run horizontally above the floor and MIFAB Series MC-10 series single or double carrier fittings shall be used. Connection to the stack in a horizontal run shall be a TY or a MC-13 carrier fitting. Where pipe space is limited, or where single fixtures are installed use MIFAB MC-14 Series. Where fixtures are located on common waste/vent stacks use MIFAB Series MC-15 series carrier fittings. * Series number denotes horizontal, vertical adjustable or vertical fixed water closet carrier. WALL HUNG URINALS Wall Hung Urinals shall be supported independently of the wall by MIFAB Series MC-32 Series Urinal Carrier with two supporting plates, heavy-duty rectangular steel uprights with integral welded feet. MC-10-L MC-32 RS FI URE C ARR IE WALL HUNG LAVATORIES Wall Hung Lavatories shall be supported independently of the wall by MIFAB Series MC-40 Series Lavatory Carrier with heavy duty rectangular steel uprights with integral welded feet. Wherever possible, fixtures shall be supplied with access for concealed arm supports and MIFAB Series MC-41 with cast ductile iron arms shall be used. Supply chrome plated escutcheons on slab type lavatories. Where fixtures are not available with access for concealed arms, fixtures shall be supported by MIFAB Series MC-31 or MC-32 for plate supported lavatories, or MC-40 for exposed arms. WHEEL CHAIR LAVATORIES Wheel chair lavatories shall be supported independently of the wall by MIFAB Series MC-42 Lavatory Carrier with extended cast ductile iron concealed arms and heavy duty rectangular steel uprights with integral welded feet. MC-41 & MC-42 with cast ductile iron arms. 140(d)

TYPICAL CLOSET CARRIER LAYOUT ANSI Standard A-112.19.2, Vitreous China Plumbing Fixtures, paragraph 5.1.3.3 states that a "Physically Handicapped" water closet is a siphon jet design that is positioned 18" from the finished floor to the top of the rim. The closet carrier layout detailed below has the following common installation dimensions: * Waste piping is pitched at 1/4 per foot * Centerline of the regular water closet outlets to the finished floor is 5 1/4 * Regular water closet rim to the finished floor is 15 1/4 * Centerline of the physically handicapped water closet outlet to the finished floor is 8 1/4 * Physically handicapped water closet rim to the finished floor is 18 The regular water closets are supported by MIFAB's MC-10-27-36 long barrel carrier fittings that are produced with a 36" long barrel. This can save the installer time and material by not having to purchase and cut waste pipe to install between standard "short barrel" carrier fittings (MC-10 Series) that are 13" long. Note that physically handicapped water closets can also be installed onto the MC-13, vertical, adjustable carrier by positioning the centerline of the 4" female threaded nipple connection in the faceplate 8-1/4" from the finished floor. 36 36 36 36 5 1/4 5 1/4 5 1/4 5 1/4 8 1/4 2 7/8 MC-13 ADJUSTABLE VERTICAL CARRIER PLUMBING STACK (BY OTHERS) 3 1/4 3 5/8 4 MC-10R-27-36 MC-10R-27-36 MC-10R-27-36 TYPICAL CLOSET CARRIER LAYOUT CENTER LINE OF FIXTURE OUTLET HEIGHT FROM FINISHED FLOOR 8 1/4 ROUGH-IN TYPICAL FOR HANDICAPPED CLOSET ROUGH IN MC-10R-27-36 PHYSICALLY HANDICAPPED CLOSET LOCATION Up to a maximum of ten fixtures may be installed on either side of the stack fitting provided that the waste drain piping is pitched 1/8" per foot. ADJUSTMENT RANGE OF MIFAB'S MC-10 AND MC-13 SERIES CARRIER FITTINGS Lowest fixture outlet and drain line position CENTERLINE DRAIN LINE POSITION FROM THE FINISHED FLOOR MINIMUM MAXIMUM C ARRIERS INT ROD UCTI ON 4 1/2 4 1/2 1/4 4 3/4 4 1/2 1/2 5 4 3/4 3/4 1/4 4 1/2 Highest fixture outlet and drain line position 5 1/2 5 1/4 1 1/4 6 5 3/4 1 3/4 6 1/2 6 1/4 2 1/4 7 6 3/4 2 3/4 7 1/2 7 1/4 3 1/4 8 7 3/4 3 3/4 8 1/4 8 4 8 1/2 8 1/4 4 1/4 8 3/4 8 1/2 4 1/2 9 1/4 9 1/2 9 8 3/4 4 3/4 9 1/2 9 1/4 5 1/4 Note: For all rough-in heights, the closet carrier fitting has a 4" vertical adjustment range. This is to ensure that there is enough drainage pitch on long runs. 141

HORIZONTAL AND VERTICAL ADJUSTABLE / FIXED CLOSET CARRIER MINIMUM SPACE REQUIREMENTS Dimensions shown are minimum assuming carrier face plate and foot are built in wall and minimum length shortened coupling is used. Dimensions shown are minimum assuming carrier fitting, face plate foot and rear anchor foot are located in pipe chase. HORIZONTAL ADJUSTABLE CARRIERS IN WALL IN PIPE CHASE MC-10L/R MC-10D MC-10L/R MC-10D VERTICAL ADJUSTABLE CARRIERS IN WALL IN PIPE CHASE MC-12/MC-13 MC-12D/MC-13D MC-12/MC-13 MC-12D/MC-13D VERTICAL FIXED OFFSET CARRIERS IN WALL IN PIPE CHASE MC-15 MC-15D MC-15 MC-15D MIFAB Inc 1321 West 119th Street Chicago Illinois 60643-5109 USA Toll Free 1-800-465-2736 Fax 773-341-3049 142