604 Water Closets and Toilet Compartments
|
|
|
- Allison Lawson
- 9 years ago
- Views:
Transcription
1 604 Water Closets and Toilet Compartments General. Accessible water closets and toilet compartments shall comply with Section Location. The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be centered in the ambulatory accessible compartment specified in Section Clearance Size. Fig Water Closet Location Clearance around the water closet shall be 60 inches (1220 mm) minimum, measured perpendicular from the side wall, and 56 inches (1420 mm) minimum, measured from the rear wall. No other fixtures or obstructions shall be within the water closet clearance.
2 604.4 Height Overlap. Fig Size of Clearance for Water Closet The clearance around the water closet shall be permitted to overlap the fixture, associated grab bars, tissue dispensers, accessible routes, and clear floor or ground space, or clearances at other fixtures and the wheelchair turning space. The top of water closet seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground. Seats shall not return automatically to a lifted position Grab Bars. Fig Height of Water Closet Grab bars for water closets shall comply with Section 609. Grab bars shall be provided on the rear wall and on the side wall closest to the water closet Side Wall. Side wall grab bar shall be 42 inches (1065 mm) long minimum, 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm)
3 minimum from the rear wall Rear Wall. Fig Side Wall Grab Bar for Water Closet The rear wall grab bar shall be 24 inches (610 mm) long minimum, centered on the water closet. Where space permits, the bar shall be 36 inches (915 mm) long minimum, with the additional length provided on the transfer side of the water closet Flush Controls. Fig Rear Wall Grab Bar for Water Closet Flush controls shall be hand operated or automatic. Hand-operated flush controls shall comply with Section Dispensers.
4 Toilet paper dispensers shall comply with Section and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet. The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the floor or ground. There shall be a clearance of 1½ inches (38 mm) minimum below and 12 inches (305 mm) minimum above the grab bar. Dispensers shall not be of a type that control delivery, or that do not allow continuous paper flow. (a) Below Grab Bar Toilet Compartments. (b) Above Grab Bar Fig Dispenser Location Accessible toilet compartments shall comply with Sections through Compartments containing more than one plumbing fixture shall comply with Section 603. Water closets in accessible toilet compartments shall comply with Sections through Wheelchair Accessible Compartments.
5 Size. Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor mounted water closets, measured perpendicular to the rear wall. (a) Wall-Hung Water Closet Doors. (b) Floor-Mounted Water Closet Fig Wheelchair Accessible Toilet Compartments Compartment doors shall not swing into the minimum required
6 compartment area Approach. Compartment arrangements shall be permitted for left-hand or righthand approach to the water closet Toe Clearance. In wheelchair accessible compartments, the front partition and at least one side partition shall provide a toe clearance complying with Section and extending 6 inches (150 mm) deep beyond the compartment-side face of the partition, exclusive of partition support members. Toe clearance at the front of the partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches 42 (1650 mm) deep with a floor-mounted water closet. Toe clearance at the side partition is not required in a compartment greater than 66 inches (1675 mm) wide. (a) Elevation
7 (b) Plan Fig Toilet Compartment Toe Clearance Ambulatory Accessible Compartments. Ambulatory accessible compartments shall be 60 inches (1525 mm) deep minimum and 36 inches (915 mm) wide. Compartment doors shall not swing into the minimum required compartment area Doors. Toilet compartment doors shall comply with Section 404, except that if the approach is to the latch side of the compartment door, the clearance between the door side of the compartment and any obstruction shall be 42 inches (1065 mm) minimum. The door shall be hinged 4 inches (100 mm) maximum from the adjacent wall or partition farthest from the water closet. The door shall be self-closing. A door pull complying with Section shall be placed on both sides of the door near the latch.
8 Grab Bars. Fig Toilet Compartment Doors Grab bars shall comply with Section Wheelchair Accessible Compartments. A side-wall grab bar complying with Section shall be provided on the wall closest to the water closet, and a rear-wall grab bar complying with Section shall be provided Ambulatory Accessible Compartments. A side-wall grab bar complying with Section shall be provided on both sides of the compartment Coat Hooks and Shelves. Coat hooks provided within toilet compartments shall be 48 inches (1220 mm) maximum above the floor or ground. Where provided, a fold-down shelf shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the floor or ground. 605 Urinals General. Accessible urinals shall comply with Section Height. Urinals shall be of the stall type or shall be of the wall-hung type with the rim at 17 inches (430 mm) maximum above the floor or ground.
9 605.3 Clear Floor or Ground Space. A clear floor or ground space complying with Section 305 positioned for forward approach shall be provided Flush Controls. Flush controls shall be hand operated or automatic. Hand-operated flush controls shall comply with Section Lavatories and Sinks General. Accessible lavatories and sinks shall comply with Section Clear Floor or Ground Space. A clear floor or ground space complying with Section 305.3, positioned for forward approach, shall be provided. Knee and toe clearance complying with Section 306 shall be provided. EXCEPTIONS: 1. A parallel approach shall be permitted to a kitchen sink in a space where a cook top or conventional range is not provided. 2. The dip of the overflow shall not be considered in determining knee and toe clearances Height and Clearances. The front of lavatories and sinks shall be 34 inches (865 mm) maximum above the floor or ground, measured to the higher of the fixture rim or counter surface Faucets. Fig Height of Lavatories and Sinks
10 Faucets shall comply with Section 309. Hand-operated, self-closing faucets shall remain open for 10 seconds minimum Bowl Depth. Sinks shall be 6 ½ inches (16512 mm) deep maximum. Multiple compartment sinks shall have at least one compartment complying with this requirement Exposed Pipes and Surfaces. Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks.
Chapter Seven: REQUIREMENT 7. Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms
Chapter Seven: REQUIREMENT 7 Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms 7 PART A: Usable Kitchens 7a...covered multifamily dwellings with a building entrance on an accessible
Bath Planning Guidelines With Access Standards
Bath Planning Guidelines With s 1: Door/Entry The clear opening of a doorway should be at least 32. This would require a minimum 2-10 door. If the existing structure precludes changing the opening then
The emergency provisions affect the following Building Code sections:
On August 1, 2012 new emergency chapter 11B code provisions became effective. Attached are copies of the emergency express terms and the applicable figures. The new requirements are underlined and deleted
Strategies for Compliant Bathrooms
(888) 341-7781 (V/TTY) - Technical Guidance www.fairhousingfirst.org 2005-2006 Designed and Developed by: The BearingPoint Team for U.S. Dept. of Housing and Urban Development C-OPC-22667 October 2005
ADA Design Guide Washrooms & Showers
ADA Design Guide Washrooms & Showers Accessories Faucets Showers Toilets Lavatories interactive version available at bradleycorp.com/adaguide.pdf Accessible Stall Design There are many dimensions to consider
Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards
Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards Last updated: 4/8/13 The Division of State Architect s (DSA) office has recently posted the Final Approved Express
PUBLIC RESTROOMS, DESIGN INTENT
PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes
Base Cabinet with Self-storing Folding Doors and Floor
Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People
City of Los Angeles Department of Building and Safety Disabled Access Section COMMERCIAL ACCESSIBILITY PLAN REVIEW LIST JOB ADDRESS CITY ZIP
GENERAL PROJECT INFORMATION PLAN CHECK NO JOB ADDRESS CITY ZIP REVIEWED BY PHONE DATE Email NOTE: Code references are to the 2014 edition of the City of Los Angeles Building Code with July 1, 2015 Supplement
Kitchen Planning Guidelines With Access Standards
Kitchen Planning Guidelines With s 1: Door/Entry The clear opening of a doorway should be at least 32 wide. This would require a minimum 2-10 door. The clear opening of a doorway should be at least 34.
Seattle Tacoma International Airport Restroom Standards
Seattle Tacoma International Airport Restroom Standards Last Updated July 10, 2015 Contents Introduction... 2 General Restroom Features:... 2 Mock up During Design... 2 Doorless Entry... 2 Entry Identification
Typical storey plan with two toilet clusters SANITARY PROVISION SANITARY PROVISION. Individual washroom. Standalone, unisex individual washroom
ACCESSIBLE TOILET REQUIREMENTS Code 2007 o Where toilets are provided at every level of a building Accessible individual washroom or WC compartment can be provided Disadvantage If WC compartment is provided,
Accessible Single Occupancy Toilet Rooms Floor Plan Examples
Accessible Single Occupancy Toilet Rooms s Chapter 11 - Accessibility Connecticut State Building Code 1999 Section 1108.2.2 The drawings on the following pages have been reproduced from handouts from the
Common ADA Errors and Omissions in New Construction and Alterations
U.S. Department of Justice Civil Rights Division Disability Rights Section Common ADA Errors and Omissions in New Construction and Alterations Introduction The ADA requires that new construction and alterations
Universal Design Recommendations for Accessible University Settings. Mauricio A. Lizama, Ph.D., ATP
INFORME TÉCNICO Unidad de Diseño, Desarrollo y Evaluación de AT PRATP Septiembre, 2009 Universal Design Recommendations for Accessible University Settings Mauricio A. Lizama, Ph.D., ATP The features listed
INTERNATIONAL RESIDENTIAL PLUMBING CODE
INTERNATIONAL RESIDENTIAL PLUMBING CODE RP2-06/07 P2705.1 Proponent: Guy Tomberlin, Fairfax County, Virginia, representing Virginia Plumbing and Mechanical Revise as follows: P2705.1General. The installation
Compliance Guide. For Title III of the Americans with Disabilities Act
Compliance Guide For Title III of the Americans with Disabilities Act The use of the term ADA Compliant herein is a description of a class of product designs and is not intended as a substitute for your
Accessibility Guide for Small Businesses
. Accessibility Guide for Small Businesses June 2015 Second Edition Preface This document is intended to provide explanation and technical guidance to assist owners of small businesses of the accessibility
REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations
Chapter Five: REQUIREMENT 5 Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations 5...covered multifamily dwellings with a building entrance on an accessible
Common ADA Errors and Omissions in New Construction and Alterations
Common ADA Errors and Omissions in New Construction and Alterations Learning Objectives Course Number: 6002 Credit Hours: 1 After completing this course you will have a better understanding of numerous
City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address
City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address July 005 Prepared by DMCG Disability Management Consulting Group L.L.C. 801 Jonquil Place Columbia, MO 650 In
Residential Plumbing BCN 1058
Residential Plumbing BCN 1058 CHAPTER 7 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System MICHAEL KNOTEK 74 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System PLUMBING FIXTURES
Effective Date: March 2015 -Rev. 5/29/2015- Void After: March 2016. Product: Ceramic Plumbing Fixtures File No. 3360
IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the
FUTRUS WALL-MOUNT VANITY SINK SOLUTIONS WITH DUPONT CORIAN
FUTRUS WALL-MOUNT VANITY SINK MODEL FWS_3018R ADA PRODUCT SPECIFICATION The wall-mount vanity sink shall be made of Corian solid surface. Bathroom module shall be 30 (762 mm) in length, 18 (457 mm) in
WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents
Chapter 1 Administration Chapter 3 General Regulations Chapter 5 Water Heaters Chapter 7 Sanitary Drainage Chapter 9 Vents Chapter 11 Storm Drainage Policy Statements Table of Contents Chapter 2 Definitions
Page 1 of 5 COMPLIANCE CHECKLIST. > Hospice Inpatient Facility Nursing Care Unit
COMPLIANCE CHECKLIST Page 1 of 5 > Hospice Inpatient Facility Nursing Care Unit The following checklist is for plan review of hospice inpatient facilities. This checklist is derived from Section 105 CMR
Subject: FO-HK Restroom Cleaning
FO SOP-H05 Page: 1 of 5 PROCEDURE: FO-HK Restroom Cleaning INTENDED AUDIENCE: All Facilities Operations Housekeeping Personnel PURPOSE: The purpose of this S.O.P. is to illustrate how to properly and thoroughly
CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.
CHAPTER 9 VENTS 901 GENERAL 901.1 Scope The provisions of this chapter shall govern the materials, design, construction, and installation of vents. 901.2 Protection of Trap Seals The protection of trap
Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit
COMPLIANCE CHECKLIST Page 1 of 6 > Long Term Care Facility - Nursing Unit The following checklist is for plan review of new long-term care facilities and new additions to existing long-term care facilities.
CHECKLIST C ACCESSIBLE TOILETS CHECKLIST
CHECKLIST C ACCESSIBLE TOILETS CHECKLIST These guidelines relate to accessible toilets for use by visitors. Different considerations may apply where accessible toilets are to be used by employees. All
ADA. Checklist for Readily Achievable Barrier Removal. The Americans with Disabilities Act. Checklist for Existing Facilities version 2.1.
Checklist for Existing Facilities version 2.1 ADA T I IT L TE S L I EI & I I II I COMPLIANCE MATERIALS To obtain additional copies of this checklist, contact your Disability and Business Technical Assistance
HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS 1226.6 PRIMARY CARE CLINICS
Compliance Checklist: [OSHPD 3] Primary Care Clinics Page 1 of 7 HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS 1226.6 PRIMARY CARE CLINICS Primary Care Clinics are Health Facilities licensed
Expanding Your Market
U.S. Department of Justice Civil Rights Division Disability Rights Section Expanding Your Market Maintaining Accessible Features in Retail Establishments Introduction More than 50 million Americans with
Typical Finished Basement Details
Fauquier County, Virginia Typical Finished Basement Details Based on the 2012 International Residential Code Finished basements must be constructed in conformance with this document. For requirements,
REQUIREMENT 3. Usable Doors
Chapter Three: REQUIREMENT 3 Usable Doors 3...covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that all the doors designed to allow passage
Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.
Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal
FIX TURE CARRI ERS. 140(a) MPB-2011-USA
FIXTURE CARRIERS STRUCTURAL FEET The feet are heavy duty cast ductile iron and invertible. No distinction is necessary between right and left hand. Each foot wraps around the specially formed edge of the
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION
Accessible. Accessible Multifamily Housing. Key Code Requirements from Volume 1-C (1999) of the North Carolina State Building Code
Accessible Accessible Multifamily Housing Key Code Requirements from Volume 1-C (1999) of the North Carolina State Building Code HOUSING HOUSING HOUSING HOUSING HOUSING HOUSING HOUSING HOUSING HOUSING
Accessible Toilets. A unisex facility should have its own entrance. It should not be entered from a single sex facility.
Accessible Toilets This is an advisory statement reflecting current statutory and current best practice requirements. It offers guidance on best practice in designing environments not only to meet the
PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES
PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES Health Systems Protection Rev. 07/2006 35-05-20/06/07/18 OFFICE OF FOOD PROTECTION 417 FEDERAL ST
Policy Name: Accessible Customer Service Plan. Form # 13.1.0. Position Responsible: VP Accreditation & Professional Development
Policy Name: Accessible Customer Service Plan 13.1.0 Policy Statement This policy is intended to meet the requirements of the Accessibility Standards for Customer Service, Ontario Regulation 429/07 under
Your Basement Remodeling Specialist LLC
Your Basement Remodeling Specialist LLC Contents Introduction 3 Remodel Details 4 Basement Bid Scope 5 Financial Arrangements 6 Homeowners Shopping Guide 7 The following is provided with your actual quote:
3. Tile used in the toilets is generally in good shape, though somewhat dated looking. The floor tile is slippery when wet.
Architectural Elements Support Facilities A. System Description 1. Architectural support facilities include the lobby, classroom, fitness room, office area, staff toilet/showers, public toilet/lockers,
R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. R432-5-2. Purpose.
R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. This rule is promulgated pursuant to Title 26, Chapter 21. R432-5-2. Purpose. The
Schedule of Maintenance Fees
Schedule of Maintenance Fees Effective July 1, 2015 It is the policy of the Housing Authority of Murray not to charge for NORMAL wear and tear. However, the Housing Authority reserves the right in every
Back Porch. Insulation Option # 2 Includes Option #1 plus, Insulate Walls Separating Both Master Suites and Leisure Room
EQUAL HOUSING TRAY CEILING Back Porch TRAY CEILING 36 Inch Plate Glass Mirror Double Hung W.I.C. Linen Shelves Hung Single Bath Coat Closet Master Suite Vestibule Laundry Insulation Option # 2 Includes
THE CENTER FOR UNIVERSAL DESIGN NC STATE UNIVERSITY College of Design. Residential Rehabilitation, Remodeling and Universal Design
THE CENTER FOR UNIVERSAL DESIGN NC STATE UNIVERSITY College of Design Residential Rehabilitation, Remodeling and Universal Design Dedication The Center for Universal Design dedicates this noteworthy publication
ACCESSIBILITY CHAPTER 11
CHAPTER 11 ACCESSIBILITY SECTION 1101 GENERAL 1101.1 Scope. The provisions of this chapter shall control the design and construction of facilities for accessibility to physically disabled persons. 1101.2
NEW YORK. Downloaded 01.15.11
Nurses Station & Resident Call System PRE 1975: NEW YORK Downloaded 01.15.11 713 1.3 Nursing units. Each nursing unit shall include the following service areas and shall meet the following minimum requirements:
Typical Finished Basement Details
Fairfax County, Virginia Typical Finished Basement Details Based on the 2012 International Residential Code Finished basements must be constructed in conformance with this document. For requirements, details
*** THIS FILE INCLUDES ALL REGULATIONS ADOPTED AND PUBLISHED THROUGH THE *** *** NEW JERSEY REGISTER, VOL. 41, NO. 4, FEBRUARY 17, 2009 ***
5:23-7.1 Applicability The provisions of this subchapter shall apply to all buildings, including their associated sites and facilities, and portions thereof, unless exempted by this subchapter. This subchapter
SECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES
SECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent
Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent Scope for Irvinton Village Unit #512 Overall Scope: Demolition, Renovation, and
ACCESS AUDIT OF WESTPORT HOUSE
ACCESS AUDIT OF WESTPORT HOUSE Large sign on the highway to indicate the entrance to Purbeck District Council Large and wide entrance Entrance showing sign for opening times Entrance sign Main entrance
PEOPLE FIRST. How to Plan Events Everyone Can Attend. Braille Accessible Print Assistive Listening Systems
PEOPLE FIRST How to Plan Events Everyone Can Attend Braille Accessible Print Assistive Listening Systems Closed Captioning Accessibility Sign Language Interpretation Information Telephone Typewriter (TTY
DuPont Surfaces. DuPont TM Corian Lavatories. TECHNICAL bulletin
DuPont Surfaces DuPont TM Corian Lavatories TECHNICAL bulletin TABLE OF CONTENTS PAGE SECTION 3 Illustration of ADA Guidelines Used 3 Options for Counters Placed 34 from Floor 4 Model 810 with Front Overflow
ADA Guide for Small Businesses
U.S. Small Business Administration Office of Entrepreneurial Development U.S. Department of Justice Civil Rights Division Americans with Disabilities Act ADA Guide for Small Businesses The U.S. Small Business
TOWN OF DAVIE BUSINESS TAX RECEIPT 6591 ORANGE DRIVE DAVIE, FLORIDA 33314-3399 PHONE: 954.797.1212 FAX: 954.797.1086 WWW.DAVIE-FL.
BUSINESS TAX RECEIPT BUSINESS TAX RECEIPT CHECKLIST FOR SUBMITTALS COMMERCIAL/INDUSTRIAL The following information is required in order for your application to be submitted for review. Items A-E are required
Plumbing Code Sections For Commercial Food Facilities
Plumbing Code Sections For Commercial Food Facilities SCOPE The following list of requirements summarizes the plumbing issues that are commonly addressed in commercial retail food facilities by health
Area of Rescue Assistance Communication System ADA Code Applicable excerpts:
Area of Rescue Assistance Communication System ADA Code Applicable excerpts: CONTENTS (Guidelines and Definitions) Page 1 Area of Rescue Assistance Requirements Page 2 Emergency Communication Equipment
New York City Department of Buildings
The New NYC Building Code Chapter 11 Accessibility New York City Department of Buildings Technical Affairs Keith Wen, R.A. Copyright Materials This presentation is protected by US and International Copyright
INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS
BATH SINKS INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Caution: All installation types need to allow room for faucet installation. Ensure adequate clearance behind the basin for your faucet and
Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842
Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842 APPLICATION for ZONING and BUILDING PERMIT APPLICATION INSTRUCTIONS:
GENERAL PLUMBING REQUIREMENTS
22 00 00 GENERAL PLUMBING REQUIRMENTS i. 01 81 00 Facility Performance Requirements ii. 22 07 00 Plumbing Insulation iii. 22 10 00 Plumbing Piping iv. 22 40 00 Plumbing Fixtures v. 22 45 00 Emergency Plumbing
Accessible reception. and service counters
Accessible reception and service counters 01 Introduction 02 Good design 04 What does the New Zealand Building Code say? 05 What does the New Zealand Standard say? 05 What s in a name? 07 What are the
2015-2016 Design Scenario Interior Design STAR Event
2015-2016 Design Scenario Interior Design STAR Event The Pocono s Children s Camp Developed with input by professional members of The American Society of Interior Designers (ASID) Project Overview and
ELECTRONIC HEALTH RECORDS AND WRITING SURFACES
ELECTRONIC HEALTH RECORDS AND WRITING SURFACES Author: Bill Zellmer AIA, CASp Issue Date: January 9, 2015 Sutter Health - Physical Access Compliance Sutter PAC Group Revisions: May 8, 2015 Barrier Interpretation
All Apartments River Village Community Bedroom Bathroom Kitchen Living Room Commons/Hallways/Stairwells Doors Windows
All Apartments Paint cost per linear foot $3.79 Drywall repair per linear foot $10.25 Drywall repair with paint cost per linear foot $14.04 Flooring cost per square foot $8.95 Item Removal Fee (Per Item)
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS ODEON IN-WALL TANK K-6283K/ K-6284K/ K-6286K Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid
2012 CODES SIGNIFICANT CHANGES 2012 IBC
2012 CODES SIGNIFICANT CHANGES 2012 IBC 1. Section 303.4 added language that includes commercial kitchens which are associated with restaurants, cafeterias, and similar dining facilities to be classified
PMA ONLINE TRAINING Venting for Plumbing Systems
PMA ONLINE TRAINING Venting for Plumbing Systems One Hour Continuing Education Venting PMA training disclaimer The information provided in this document is intended for use as a guideline and is not intended
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
DESIGN GUIDELINES FOR SUBSTANTIAL REHABILITATION.
1 DESIGN GUIDELINES FOR SUBSTANTIAL REHABILITATION. I. APPLICABILITY OF GUIDELINES. The design guidelines apply to the rehabilitation of multi-family buildings, subject to H.P.D. review and approval. The
GENERAL PLUMBING REQUIREMENTS
22 00 00 GENERAL PLUMBING REQUIRMENTS i. 00 00 07 Design Professional Design Process Requirements ii. 00 00 08 Design Professional Documentation Requirements and Deliverables iii. 01 81 00 Facility Performance
What to Expect From the Examination. How to Study the Plumbing Codes
Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.
Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot
Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot Craig Selover Selover Consulting [email protected] H:248 542-3010 C:248 917-1380 Floor Plan Floor Plan All Piping WaterSense,HERS,
WAW-2311 WAW-2322 WAW
COMMERCIAL PRODUCT GUIDE Plumbing Fixtures & Accessories MADE IN THE USA Willoughby Industries has manufactured commercial grade stainless steel and solid surface plumbing products for more than 65 years.
Sealant. 30" Model No. 35020. D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation
INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE London Kitchen Sinks 24" Sink model number 35030 30" Sink model number 35020 36" Sink model number 35040 Thank you for selecting Porcher. To ensure this product
Technical Bulletin: Understanding the ADA and Implications for Office Design
Technical Bulletin: Understanding the ADA and Implications for Office Design What is the ADA? The Americans with Disabilities Act (ADA) is a federal law enacted in 1990. It prohibits discrimination on
SPACE TYPE: AUDITORIUM
SPACE TYPE: AUDITORIUM Construction Criteria The unit costs for space types are based on the construction quality and design features in the following table. This information has been generally organized
TIPS TO PREPARE FOR MOVING OUT OF YOUR UNIT Cleaning Tips and Price List
TIPS TO PREPARE FOR MOVING OUT OF YOUR UNIT Cleaning Tips and Price List The Residence Life Department wants to provide you with a few handy cleaning tips so that you can leave your room in tip top shape
Furniture. Portsmouth Vanity and Centerset Faucet. On the Cover: 0283.008 Standard Collection Console Table, 8710.000 Console Table Legs
Furniture & Sinks Furniture 03 Portsmouth Vanity and Centerset Faucet On the Cover: 0283.008 Standard Collection Console Table, 8710.000 Console Table Legs American Standard s bath furniture is designed
New or Remodeled Food Service Establishment Checklist**
ToTo Protect and Promote the Health and the Environment of the People of Kittitas County New or Remodeled Food Service Establishment Checklist** **Some items may not be required for limited food service