PROCESS AUTOMATION JUNCTION BOX SELECTION GUIDE FOR FIELDBUS INFRASTRUCTURE



Similar documents
PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

TECHNICAL WHITE PAPER LIFE CYCLE POLICY FOR THE CHEMICAL, PETROCHEMICAL AND PHARMACEUTICAL INDUSTRIES

Intelligent Fieldbus Keeps your Process Running

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

PROCESS AUTOMATION VISUNET INDUSTRIAL SYSTEMS

RELIABLE SIGNALS INTERFACE TECHNOLOGY PRODUCT OVERVIEW

PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

DeviceNet, Panel Mount Junction Box

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

FACTORY AUTOMATION LGS SERIES INTELLIGENT

How To Use A Network Card With A Network Box (Ios) On A Microsoft Powerbook 2.5 (I2) (I3) (Io2) And I2 (Io) (Net) (Ipo) (

mpm DIN CONNECTORS

Amphenol LTW Technology Co., Ltd. Amphenol LED Market. Innovation in Waterproof Solution

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS

PROCESS AUTOMATION. ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW

The Power of Electrical Engineering

FCS-MBx-SG Megablock series*

Digital display DA 48

SAFETY MANUAL SIL Switch Amplifier

400 Series - Mini USB Buccaneer

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Microcor Wireless Transmitter (MWT)

FACTORY AUTOMATION EXPERTISE AND SERVICE OPEN DOORS RADAR SENSORS FROM PEPPERL+FUCHS

AUTOMOTIVE EXCELLENCE

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Software Release Notes - FieldConnex Diagnostic Manager

Network Connectivity. Your link for dependable routing of signal and data in industrial environments

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

M-series FOUNDATION Fieldbus I/O

SYSTEM DESCRIPTION Termination Boards

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Rosemount 333 HART Tri-Loop

TECHNICAL WHITE PAPER INTRINSICALLY SAFE FIELDBUS IN HAZARDOUS AREAS

A99B Series Temperature Sensors

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

Technical Data. Dimensions

HARTING Ethernet Cabling 4-poles Overview

TELEPHONES Accessories. Phones. parts. Keypad Telephones Auto Dial. Courtesy Inmate Telephones. Hands-Free Telephone. Catalog.

LED...A Q Series Sealed High-Intensity

Type testing

Inductive sensor NI10-M18-Y1X-H1141

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

HARTING Ethernet Cabling 8-poles Overview

General 1-2-Opto-electronics Safety Switches 4-Emergency

THERMAL MANAGEMENT SOLUTIONS

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Build A Powerline Box Powerline Generator

PURGE/PRESSURIZATION SYSTEM

Solar Power Solutions

Low Frequency Velocity Sensor

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

DuroSite LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

PROCESS AUTOMATION MANUAL R2-SP-N*

Electronic Pressure Switch EDS 300

IMVIB. Online vibration monitoring for Ariel compressors

FACTORY AUTOMATION LASER BARCODE SCANNERS FOR INDUSTRIAL AUTOMATION

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Mini USB and USB 2.0-IP67 Connector System

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Testing Accessories. Test PaddleS. Insulated Socket Wrench Jumper Strips Test Lead Kit. Test Paddle Attachment Clips Plugs Binding Posts

MTL Fieldbus Network Solutions. Delivering high reliability in Fieldbus Networks

Solenoid Valve Island Type 3965

Lightning Arresters P KVA P KVA. Description & Installation

A&C Solutions: please contact us.

FACTORY AUTOMATION POSITION TRACKING SYSTEM WCS2B/WCS3B

TRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas

Digital inductive conductivity transmitter

DeviceNet, minifast Conduit Adapters

SECTION OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

PROCESS AUTOMATION LEVEL MEASUREMENT VIBRATION AND GUIDED MICROWAVE

Standard Buccaneer - USB

PROCESS AUTOMATION. System Manual CREST. Fieldbus Power Hub

Directory chapter 04

RAY-MAX Integrated Solar Power Strip

40.3. Control Relays and Timers

TYPE APPROVAL CERTIFICATE

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Compact pressure switch Flameproof enclosure Ex d Model PCA

Transcription:

PROCESS AUTOMATION JUNCTION BOX SELECTION GUIDE FOR FIELDBUS INFRASTRUCTURE

ENCLOSURE SOLUTIONS FOR FIELDBUS DISTRIBUTION Delivering Solutions For the last 50 years, Pepperl+Fuchs has been a world leader in hazardous area protection, always striving to provide our customers with the latest technologies in the most costeffective manner. Committed to providing our customer with a competitive edge, we now offer our expertise in designing and building enclosure solutions. Our FieldConnex segment protector and FieldBarrier wiring interfaces are now available in ready-toinstall field junction boxes. Our fieldbus junction box solutions are tailored to meet the demanding needs of harsh operating environments. This value-added solution results in reduced engineering and installation costs. Junction boxes are available in a variety of housing materials and enclosure designs. Our off-theshelf solutions offer a quick turn around for your next project. Typical field junction box We not only offer a complete range of solutions for fieldbus installations, we can also develop custom solutions tailored to specific requirements. If your enclosure needs are on a much larger scale, allow our application engineers to develop your unique solution. This reduces in-house engineering efforts and costs. From concept and design to startup and commissioning, Pepperl+Fuchs will provide custom-engineered field boxes manufactured in our UL508A, UL698A, and CSA approved panel shop. This guarantees the consistent superior quality you have come to expect from Pepperl+Fuchs. Custom engineered solutions are completed in-house by our experts, and we can provide CAD drawings in 2-3 business days.

Distributed Architecture In process plants throughout the world, segment protectors and FieldBarriers are used as key components in the distribution of fieldbus networks from the control room to the field instruments. A trunk and spur topology is commonly used. In a typical fieldbus installation, 10-12 fieldbus devices are connected via one cable run that can span between 1500-1900 meters. This one cable supports power and communication to all the devices; therefore, it is recommended to use short circuit protection and energy limitation to isolate a fault condition from negatively affecting device communications on that segment. One device is connected to the output spur of a segment protector or FieldBarrier. Fieldbus junction boxes are installed close to the instruments in the field in one of two ways depending on the location of the instrumentation: Highly Distributed Architecture Multiple segment protectors and FieldBarriers may be packaged together or combined with other components for a custom distribution panel DCS Distributed Architecture One segment protector/fieldbarrier per enclosure DCS Power Supply Power Supply Junction Box Junction Box Junction Box Field Devices Field Devices

BUILDING A STANDARD JUNCTION BOX Painted Steel Stainless Steel Polycarbonate Fiberglass Choose Your Material The enclosure material is an important consideration in planning the fieldbus network distribution, and it is critical to the overall success of the installation and longterm stability of fieldbus communications. Materials differ tremendously in their physical strength; however, the strength of a material does not determine its resistance to corrosion, water, or other outdoor elements. Aluminum (Segment Protector) Aluminum (FieldBarrier) Polycarbonate Fiberglass Painted Steel Aluminum Stainless Steel Options (cord grips & connectors) available available available available available Dimensions (inches) 9.2 x 6 x 3.3 9.6 x 7.5 x 4.7 10 x 8 x 4 10.1 x 4.5 x 3 10 x 8 x 4 Temperature Range ( C) -35 to +70-35 to +70-40 to +70-40 to +70-40 to +70 IP/NEMA Ratings IP 67 / NEMA 4, 4X, 6, 12, 13 NEMA 4X, 6P, 12 IP 66 / NEMA 4, 12, 13 NEMA 4X IP 66 / NEMA 4, 4X, 12, 13

Choose Your Cable Connection Whether the installation specifies conduit, or armored or PLTC/ ITC cable from the control room to the junction box, we have a wide range of solutions to make installation quick and easy. It is not uncommon to have different trunk and spur connections, i.e., conduit adapter on the trunk in/out and quick disconnect receptacles on the spurs. If you have a specific gland requirement, contact us for a solution. Mini Receptacle NPT Conduit Stainless Steel Plastic Nickel-Plated Brass

BUILDING A STANDARD JUNCTION BOX Choose Your Distribution Module Segment protectors and FieldBarriers are key components in the distribution of the Fo u n d at i o n fieldbus and PROFIBUS PA networks from the control room to the field instruments. FieldConnex distribution modules offer best-in-class segment reliability and simplified installation. Select the distribution interface that matches the application. Segment Protectors: General-Purpose, Div. 2/Zone 2 Segment protectors (current limiting devices) provide additional dependability to the fieldbus network; they isolate a single short from affecting the entire network. FieldConnex segment protectors simplify installation and reduce the likelihood of miswiring or over-termination. When the fault is repaired, the segment protector automatically resumes operation of the spur. R2 Segment Protector: The innovative design provides simple installation of field instruments. A key feature is the trunk T-connector. It provides a single location for the terminator, and the segment protector can be replaced without disturbing the trunk. R2 segment protectors support 4-12 spurs. RM Modular Segment Protector: The trunk module connects the unit to the segment and also has two output spurs. Each expansion module has four spurs and simply snap side-by-side on a DIN rail with a system plug for connection. RM segment protectors support 2-26 spurs. FieldBarrier: Zone 1/Class I Div. 1 Spurs (Entity/FISCO Outputs) The FieldBarrier can be installed in Zone 1/Div. 2. In addition to short-circuit protection the FieldBarrier offers galvanic isolation. Each intrinsically safe output can be up to 120 m long. This permits installation of field instruments in Zone 0/Div. 1 and allows live maintenance on the instruments. R2 Segment Protectors RM Segment Protector Available as a custom junction box solution FieldBarrier F2D0-FB-EX4 or available as a custom junction box solution

SPJB - 10 - SS. CGS Build an R2 Segment Protector Junction Box Model Number Select the distribution module, number of spurs, connection type, and enclosure material to build your model number. Segment Protector Junction Box Number of Spurs 4,6,8,10,12 Enclosure Material SS Stainless Steel SSW Stainless Steel with Window CS Carbon Steel CSW Carbon Steel with Window PCW Polycarbonate with Window FB Fiberglass FBW Fiberglass with Window AL Aluminum Connection Type NF No Fitting ½ CB ½" NPT Conduit 7/8S 7/8" Mini Receptacle CGP Plastic Cable Gland CGB Nickel-Plated Brass Gland CGS Stainless Steel Gland

CUSTOM ENCLOSURES BUILT TO YOUR SPECIFICATION OFFER TRE Customize Your Junction Box Pepperl+Fuchs is more than just a hazardous location supplier, we put things together. Allow our trained engineering staff to assist in the design and documentation of your next custom junction box. Our experienced design engineers use AutoCAD to provide quick turnaround on panel layout drawings and will explore all design options to ensure the most cost-effective solution. A custom enclosure, built to your specification, saves time and provides reduced startup and installation costs. Consider the versatility of incorporating multiple segment protectors, FieldBarriers, as well as lightning surge protection or Pepperl+ Fuchs Bebco EPS purge solutions into a single enclosure. Our standards for quality and craftsmanship combined with our competitive prices make Pepperl+Fuchs an excellent choice for your next project. Reduced in-house engineering Installation savings Enclosures designed and built in our facility UL508A, UL698A, and CSA approved panel shop Multiple FieldBarriers can be packaged with other components, such as surge protection, for a custom solution.

MENDOUS VERSATILITY AND COST SAVINGS Pepperl+ Fuchs Bebco EPS Purge Pressurization products offer a safe and economical approach to installing electrical equipment in hazardous locations. By creating a safe area inside the enclosure, general-purpose equipment can be used in hazardous (classified) areas. Applications & Markets Where We Specialize Installing signal conditioners and intrinsic safety isolator termination boards in the field replaces manual point-to-point wiring and long cable runs back to the control system cabinet. This shift saves a tremendous amount of time and money. Distributed fieldbus junction boxes are a money-saving option when there is a large grouping of field instruments.

ACCESSORIES Quick Disconnect Cables and Bulk Fieldbus Cable Our Type A/ER molded cordset and extension cables are manufactured with PLTC/ITC ER-rated cable. Exposed Run (ER) cable is more robust and has a crush-resistant construction. ER cable can run up to 15 meters outside an open cable tray or conduit reducing the overall installation time and cost. Quick disconnect connectors make installation and disconnection quick and easy. Male-female molded extension cables eliminate common hard wiring errors. In the North American fieldbus market we typically see female cordsets (female molded connector with flying leads). The fieldbus cable is hard wired at the field junction box and has a molded connector at the instrument. Armored Fo u n d at i o n Fieldbus Extension Cables & Cordsets See online part no. configurator at http://www.am.pepperl-fuchs.com/fieldconnex/configurator.jsp C-V9F-G-BK- *M-ACL-V9M-G-FF-S AL armored extension cable * = lengths 1-300 m C-V9F-G-BK- *M-ACL-0-0-FF-S AL armored female cordset * = lengths 1-300 m Fo u n d at i o n Fieldbus Type A/Exposed Run Extension Cables & Cordsets (4-pole S.S. coupling nut) C-V9F-G-OR-*M-ER-V9M-G-FF-S (7/8) extension cable * = lengths 1-250 m (stocked lengths 1,2,5,10,15,20, 25,30, and 50 meters) C-V1F-G-OR-*M-ER-V9M-G-FF-S (M12) extension cable * = lengths 1-250 m (stocked lengths 1,2,5,10,15,20, 25,30, and 50 meters) C-V9F-G-OR-*M-ER-0-0-FF-S (7/8) female cordset * = lengths 1-250 m (stocked lengths 1,2,5,10,15,20, 25,30, and 50 meters) C-V1F-G-OR-*M-ER-0-0-FF-S (M12) female cordset * = lengths 1-250 m (stocked lengths 1,2,5,10,15,20, 25,30, and 50 meters) Bulk Fieldbus Type A Exposed Run Cable * = OR (Orange) * = BL (Blue) C-*- 300 Fieldbus Type A: shield TP, 18 AWG - PVC type PLTC, ITC cable, 300 m (1000 ft) C-*- 750 Fieldbus Type A: shield TP, 18 AWG - PVC type PLTC, ITC cable, 750 m (2500 ft) C-*- 1500 Fieldbus Type A: shield TP, 18 AWG - PVC type PLTC, ITC cable, 1500 m (5000 ft) Bulk Fo u n d at i o n fieldbus multicore - orange C-OR-* MC-300 Fieldbus Type A: * 2, 5 or 8 shield TP Pair, 18 AWG multicore PVC type A PLTC, ITC cable, 300 m (1000 ft) Bulk Fo u n d at i o n fieldbus armored Type A - black C-A-300 Type A fieldbus cable with aluminum armor, 18 AWG, PLTC/CM/ITC 300 m (1000 ft) Fieldbus Physical Layer Diagnostics Increase commissioning efficiency and reduce operating cost with online diagnostics that continuously evaluate the fieldbus physical layer. The Advanced Diagnostic Module (ADM) is a tool for comprehensive commissioning diagnostics for the fieldbus physical layer for both Fo u n d at i o n fieldbus H1 and PROFIBUS PA. The ADM simplifies device installation and loop checks through the node commission wizard and sets notification levels for signal degradation and easy troubleshooting from the control room. Advanced Physical Layer Diagnostics COMM-KT Fieldbus commissioning kit, 120 V 500 ma PS, 24 V fieldbus PS (No DM-AM/DTM license) ADM-COMM-KT Fieldbus commissioning kit, 120 V 500 ma PS, 24 V fieldbus PS, DM-AM/DTM license ADM-COMM-NI-KT DM-AM-KIT DTM-FC.ADM Fieldbus commissioning kit, 120 V 500 ma PS, 24 V fieldbus PS, DM-AM/DTM license & National Instruments FF H1 interface Mobile ADM Kit, includes ADM, carrying case, mounting bracket, cables & screw driver Professional DTM license for Mobile ADM

Accessories Fieldbus accessories make installation easier. We have a variety of mini and micro instrument receptacles, receptacle covers, and cable gland plugs in plastic, stainless steel, and nickelplated brass. Mini and micro field attachable connectors are available to make quick disconnect cable connections in the field. Field Attachable Connectors V1-FA-M-B M12, male, NPB, shielded (right angle available) V1-FA-F-B M12, female, NPB, shielded (right angle available) V9-FA-M-B 7/8, male, NPB, shielded (right angle available) V9-FA-F-B 7/8, female, NPB, shielded, straight (right angle available) V9-FA-M-S 7/8, male, plastic W/ SS, straight (right angle available) V9-FA-F-S 7/8, female, plastic W/ SS, straight (right angle available) Instrument Receptacles V9-R-M-S V9-R-M-A V9-R-M2-S V1-R-M-S V1-R-M2-S 7/8 (mini) male 1/2 NPT, 18 AWG, SS 7/8 (mini) male 1/2 NPT, 18 AWG, aluminum 7/8 (mini) male 1/2 NPT, 18 AWG, SS, 2-wire 7/8 (mini) male 1/2 NPT, 18 AWG, SS, 4-wire 7/8 (mini) male 1/2 NPT, 18 AWG, SS, 2-wire Other Accessories M20-CG-PLUG V9-CL VAZ-VR-1 V9-R-F-COV JB-BR-TB M16-NPT-CON C-V9-TEE-A C-V9-TEE-S M20 cable gland plug enclosure Mini connector lock, 10 pieces/bag M12 male receptacle cover 7/8 female receptacle cover nylon Insertion bridge - 2 position, 10 pieces Adapter - M16 to 1/2 NPT-brass 4-pole mini tee, aluminum 4-pole mini tee, S.S. Fieldbus Surge Protection DB-LB-I DP-LBF-I1.34 DB-LB DP-LBF-1.34 FN-LBF-D1.32 FN-LBF-I1.32 DIN rail base module, I.S. I.S. protection module DIN rail base module, general-purpose General-purpose protection module 1/2 NPT screw in surge protection, general-purpose 1/2 NPT screw in surge protection, I.S. fieldbus Terminators KMD0-FT-EX FN-FT-EX1.D.IEC DIN rail fieldbus terminator, I.S. or safe area Screw mount terminator, I.S. or safe area

process automation protecting your process For over a half century, Pepperl+Fuchs has provided new concepts for the world of process automation. Our company sets standards in quality and innovative technology. We develop, produce and distribute electronic interface modules, Human-Machine Interfaces and hazardous location protection equipment on a global scale, meeting the most demanding needs of industry. Resulting from our world-wide presence and our high flexibility in production and customer service, we are able to offer complete individual solutions wherever and whenever you need us. We are the recognized experts in our technologies Pepperl+Fuchs has earned a strong reputation by supplying the world s largest process industry companies with the broadest line of proven components for a diverse range of applications. 6 5 3 1 7 4 1 2 Worldwide/German Headquarters Pepperl+Fuchs GmbH Mannheim Germany Tel. +49 621 776 2222 E-Mail: pa-info@de.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs PTE Ltd. Singapore Company Registration No. 199003130E Tel. +65 6779 9091 E-Mail: pa-info@sg.pepperl-fuchs.com 8 2 3 4 5 Central/Western Europe & Africa Headquarters Pepperl+Fuchs N.V. Schoten/Antwerp Belgium Tel. +32 3 6442500 E-Mail: pa-info@be.pepperl-fuchs.com Middle East Headquarters Pepperl+Fuchs M.E (FZE) Dubai UAE Tel. +971 4 883 8378 E-Mail: pa-info@ae.pepperl-fuchs.com North/Central America Headquarters Pepperl+Fuchs Inc. Twinsburg Ohio USA Tel. +1 330 486 0002 E-Mail: pa-info@us.pepperl-fuchs.com Northern Europe Headquarters Pepperl+Fuchs GB Ltd. Oldham England Tel. +44 161 6336431 E-Mail: pa-info@gb.pepperl-fuchs.com www.pepperl-fuchs.com 6 7 8 Southern/Eastern Europe Headquarters Pepperl+Fuchs Elcon srl Sulbiate Italy Tel. +39 039 62921 E-Mail: pa-info@it.pepperl-fuchs.com Southern America Headquarters Pepperl+Fuchs Ltda. São Bernado do Campo SP Brazil Tel. +55 11 4341 8448 E-Mail: pa-info@br.pepperl-fuchs.com Subject to modifications 2009 PEPPERL+FUCHS, INC. Printed in USA Part No. 912658 06/09 00