Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction



Similar documents
Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Model 3051 Pressure Transmitter with HART Protocol

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop

Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices

Best Practices for Reducing Transmitter Life Cycle Costs

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Replacing Displacers with Guided Wave Radar

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Rosemount 1199 Submersible Seal

Model 1756 Test Lead Kit

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

ProductDiscontinued. Rosemount 3095 MultiVariable Mass Flow Transmitter with HART or FOUNDATION Fieldbus Protocol

Import the Gateway Certificate to the Browser

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Hard Disk Drive (HDD)

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Rosemount 751 Field Signal Indicator

SERVICE GUIDE. Gateway Notebook

ATS Overhead Table Shelf System INSTRUCTION MANUAL

How To Set Up An Inverter

Thermocouple Thermometer Models

PTU Series Ultrahigh-Purity Pressure Transducers

Sunny Boy Accessories SMA POWER BALANCER

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Rosemount 708 Wireless Acoustic Transmitter

SECURITY SYSTEM SMART SIREN KIT

Installation Instructions

Reference Manual , Rev AB January Rosemount 3051S Electronic Remote Sensors

GENUINE PARTS INSTALLATION INSTRUCTIONS

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

AGILENT E5071C ENA NETWORK ANALYZER

Operating Instructions Electronics module VEGADIF 65

Cable Drum Machine. Operation Manual BC260 SERIES. Cleans 1 1/4" to 3" lines up to 50'

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

SDX Submersible Depth Transmitter User Manual

ATEX Zone 2 and 22 Installation Drawings and Instructions

Safety instructions VEGADIS DIS81.CEIA/V****

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

MCR1900 Media Converter 19-Slot Chassis

Technical Data. Dimensions

Micro Motion Model 2200S Transmitters

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Changing the SIM in a BANDIT Product s GSM Card

CELO5. User & Installation Manual.

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

3. Loosen 3 x grub screws in the Dec end cap and unscrew the cap and counterweight shaft. NEQ6 Belt Modification Kit.

Wiper Motor Marinco 2.5. Installation Instructions

IMPORTANT SAFETY NOTICE

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Reference Manual , Rev BB August Rosemount Graphical Field Display.

Instructions A Amp AC/DC Current Probe

Your safety and the safety of others are very important.

Rosemount 248 Temperature Transmitter

Plus ESG50GL Battery-powered, High-speed Cable Cutter

UniStream CPU-for-Panel

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

EasyNote TJ Series. Disassembly Manual

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

S-series Mass Connection Solutions

Advantium 2 Plus Alarm

Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications

Operating Instructions

Refer installation of power supplies to qualified service personnel.

Service Guide. Gateway M275

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

RayClic Connection System Installation Instructions

5800 Temperature Sensor Cable Assembly

Installation Instructions S

Small form factor bay converter and hard drive installation

LUCCI AIRFUSION QUEST II CEILING FAN

Wolflite Safety Handlamp H-251E

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Emerson Smart Wireless Gateway Solutions

PBX Series Quick Fit Connector Bimetallic Steam Traps

Rosemount 3051 Pressure Transmitter

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Rosemount 3051 Pressure Transmitter. Rosemount 3051CF Series Flowmeter Transmitter

6 inch A-Arm Lift Kit WARNING: / installation instructions. will fit CLUB CAR DS. included:

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Dissolved Oxygen Sensors

Series Hose Reels

G670 Intermittent Pilot Ignition Controls

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

HP UPS R1500 Generation 3

Transcription:

Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages................................. page S-2 Overview....................................... page S-3 Exchange Procedure............................. page S-4 Removing the Transmitter Head.................... page S-4 Exchanging the.................... page S-6 Exchanging the EMC Board - Transmitter Without a Barrier Board................. page S-9 Exchanging the EMC Board - Transmitter With a Barrier Board................... page S-12 Exchanging the Barrier Board...................... page S-15 Part Number References.......................... page S-19 INTRODUCTION This instruction is a supplement to the Rosemount 5300 Series Reference Manual (Document No. 00809-0100-4530) and the Rosemount 5400 Series Reference Manual (Document No. 00809-0100-4026). It describes how to exchange the, the EMC Board, and the Barrier Board on a Rosemount 5300 and 5400 Series transmitter. NOTE This instruction is valid for Transmitter Heads with a manufacturing date of September 2006, and later. For Part Number references, see Part Number References on page S-19. This instruction is not valid for Product Certification model code E4, or Option model code QS. NOTE The exchange of, EMC Board, or Barrier Board must be documented! This includes stating the serial number of the instrument, date of exchange, type of exchange, and service technician. Tools The following tools are needed: A 50 mm wrench (Rosemount 5300 Series) or a 60 mm wrench (Rosemount 5400 Series) is used to unscrew the nut when removing the transmitter head A screw driver is used to disconnect the cables Plastic bag or cloth for antenna and tank seal protection Wrench for removing cable glands www.rosemount.com

Rosemount 5300 and 5400 Series Manual Supplement SAFETY MESSAGES Procedures and instructions in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that raises potential safety issues is indicated by a warning symbol ( ). Please refer to the following safety messages before performing an operation preceded by this symbol. Failure to follow safe installation and service guidelines could result in death or serious injury Make sure the transmitter is installed by qualified personnel and in accordance with applicable code of practice. The transmitter may only be maintained and repaired by qualified personnel. The applicable standards and legal requirements as well as any product certificates have to be observed. Only original spare parts may be used. Use the equipment only as specified in the Rosemount 5300 Series Reference Manual (Document No. 00809-0100-4530), the Rosemount 5400 Series Reference Manual (Document No. 00809-0100-4026), and in this Manual Supplement. Failure to do so may impair the protection provided by the equipment. Do not perform any services other than those contained in this manual unless you are qualified. Explosions could result in death or serious injury Verify that the operating environment of the transmitter is consistent with the appropriate hazardous locations specifications. To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Before connecting a HART or FOUNDATION fieldbus based communicator in an explosive atmosphere, make sure the instruments in the loop are installed in accordance with intrinsically safe or non-incendive field wiring practices. To avoid process leaks, only use o-rings designed to seal with the corresponding flange adapter. Electrical shock can result in death or serious injury Avoid contact with the leads and terminals. High voltage that may be present on leads can cause electrical shock. Make sure the main power to the Rosemount 5300 Series transmitter or Rosemount 5400 Series transmitter is off and the lines to any other external power source are disconnected or not powered while wiring the transmitter. Probes with non-conducting surfaces Probes covered with plastic and/or with plastic discs may generate an ignition-capable level of electrostatic charge under certain extreme conditions. Therefore, when the probe is used in a potentially explosive atmosphere, appropriate measures must be taken to prevent electrostatic discharge. S-2

Manual Supplement Rosemount 5300 and 5400 Series OVERVIEW EMC Board Barrier Board (optional) (1) Display Terminal compartment Cable gland Nut 50 mm (Rosemount 5300) Nut 60 mm (Rosemount 5400) Locking screw (ATEX, IECEx flameproof versions) To unlock: tighten screw. To lock: unscrew until it locks against cover. Exchange Procedure Summary NOTE Before starting the exchange procedure read and follow the Safety Messages on page S-2. Use the following procedure to exchange a, and/or an EMC Board, or Barrier Board: 1. Do not remove the instrument cover in explosive environments if the circuit is live. Disconnect/shut off the electrical power to transmitter head and then open the instrument cover. Disconnect the wiring, pull the cables out through the glands, and bring the transmitter head to a suitable location for maintenance work. See Removing the Transmitter Head on page S-4. 2. Exchange the, see Exchanging the on page S-6. 3. Exchange the EMC Board, see Exchanging the EMC Board - Transmitter Without a Barrier Board on page S-9. If the transmitter is equipped with a Barrier Board (1), see Exchanging the EMC Board - Transmitter With a Barrier Board on page S-12. To exchange the Barrier Board, see Exchanging the Barrier Board on page S-15. 4. Place the transmitter head on the tank seal and make sure that the nut is properly tightened. 5. Connect the wires. 6. Tighten the cover to the terminal compartment. 7. Power up the transmitter. 8. Verify proper operation. (1) This instruction is valid for Product Certification model codes E1, E2, E3, E5, E6, E7, KA, KB, KC, and KD. S-3

Rosemount 5300 and 5400 Series Manual Supplement EXCHANGE PROCEDURE Removing the Transmitter Head This section describes the different steps to exchange the and/or the EMC Board, or the Barrier Board on a Rosemount 5300 or Rosemount 5400 Series transmitter. 1. Removing the Transmitter Head section describes how to disconnect wiring and remove the transmitter head from the antenna. 2. Exchanging the section describes how to remove and replace the. 3. Exchanging the EMC Board - Transmitter Without a Barrier Board describes how to remove and replace the EMC Board. 4. Exchanging the EMC Board - Transmitter Without a Barrier Board describes how to remove and replace the EMC Board on a transmitter with a Barrier Board. 5. Exchanging the Barrier Board section describes how to remove and replace the Barrier Board. 1. Disconnect the power supply. All power to the transmitter is supplied over the signal wiring. 2. For ATEX, IECEx, and NEPSI installations, unlock the locking screw (tighten screw) and remove the cover. Do not remove the cover in explosive atmospheres when the circuit is live. Cover Locking Screw 3. Make a note which cables are connected to the plus (+), minus (-), and ground terminals, and disconnect the cables using a screw driver. 4. Pull the cables out through the cable gland/conduit. Plus (+) Minus (-) Ground S-4

Manual Supplement Rosemount 5300 and 5400 Series 5. Loosen the nut using a wrench. Nut 6. Lift the transmitter head away from the tank seal. Cover the tank seal with a plastic bag or cloth to protect the exposed parts from dust, rain, moisture etc. during the exchange procedure. 7. Bring the transmitter head to a suitable location for maintenance work and continue with exchanging the, EMC Board, or Barrier Board. Make sure to follow proper protection procedures in order to avoid damage from Electrostatic Discharges (ESD). S-5

Rosemount 5300 and 5400 Series Manual Supplement Exchanging the Terminal Block 1. Remove the two screws that hold the. 2. Pull the out of the compartment. 3. Separate the from the EMC Board. If the transmitter is equipped with the optional Barrier Board, the may be separated from the EMC Board when it is pulled out of the compartment. EMC Board S-6

Manual Supplement Rosemount 5300 and 5400 Series 4. Verify that the Part Number of the new is correct, see Part Number References on page S-19. Part Number 5. Attach the new to the EMC Board. 6. Insert the with the EMC Board into the compartment, making sure that the cable to the EMC Board is not jammed inside the terminal compartment. Tip: rotate the /EMC Board 360 counterclockwise before inserting into the compartment. Make sure the cable is not jammed 7. Secure the /EMC Board with the two screws. Tighten by hand. 8. Remove the cover from the tank seal. Mount the transmitter head on the tank seal and make sure the nut is properly tightened. Nut 50 mm (Rosemount 5300) Nut 60 mm (Rosemount 5400) S-7

Rosemount 5300 and 5400 Series Manual Supplement 9. Connect the signal wires and grounding. 10. Tighten the cover to the terminal compartment and tighten the cable glands, making sure that the cover is secured to meet explosion-proof requirements. For ATEX, IECEx, and NEPSI installations, lock the cover with the locking screw. See Overview on page S-3. 11. Power up the transmitter and verify proper operation. S-8

Manual Supplement Rosemount 5300 and 5400 Series Exchanging the EMC Board - Transmitter Without a Barrier Board This section describes changing the EMC Board for Rosemount 5300 and Rosemount 5400 Series transmitters without a Barrier Board. See Exchanging the EMC Board - Transmitter With a Barrier Board on page S-12 if the transmitter is equipped with a Barrier Board. To change the EMC Board: 1. Remove the transmitter head (see Removing the Transmitter Head on page S-4). 2. Remove the two screws that hold the. 3. Pull the and the EMC Board out of the compartment. 4. Separate the from the EMC Board. EMC Board S-9

Rosemount 5300 and 5400 Series Manual Supplement 5. Disconnect the cable from the connector on the back of the EMC Board. 6. Verify that the Part Number of the EMC board is correct. See Part Number References on page S-19. Label with Part Number 7. Connect the cable to the new EMC Board. 8. Attach the to the new EMC Board and insert them into the compartment, making sure that the cable to the EMC Board is not jammed inside the terminal compartment. Tip: rotate the 360 degrees counterclockwise before inserting into the compartment. Make sure the cable is not jammed 9. Secure the /EMC Board with the two screws. Tighten by hand. S-10

Manual Supplement Rosemount 5300 and 5400 Series 10. Remove the cover from the tank seal. Mount the transmitter head on the antenna and make sure the nut is properly tightened. Nut 50 mm (Rosemount 5300) Nut 60 mm (Rosemount 5400) 11. Open the terminal compartment and connect signal wires and grounding. 12. Tighten the cover to the terminal compartment and tighten the cable glands, making sure that the cover is secured to meet explosion-proof requirements. For ATEX, IECEx, and NEPSI installations, lock the cover with the locking screw. See Overview on page S-3. 13. Power up the transmitter and verify proper operation. S-11

Rosemount 5300 and 5400 Series Manual Supplement Exchanging the EMC Board - Transmitter With a Barrier Board This section describes how to change the EMC Board for Rosemount 5300 and Rosemount 5400 Series transmitters with a Barrier Board (1). See section Exchanging the EMC Board - Transmitter Without a Barrier Board on page S-9 if the transmitter has no Barrier Board. To change the EMC Board do the following: 1. Remove the transmitter head (see Removing the Transmitter Head on page S-4). 2. Remove the two screws that hold the. 3. Pull the and the EMC Board out of the compartment. EMC Board Barrier Board 4. Verify the Part Number of the new EMC Board, see Part Number References on page S-19. Label with Part Number (1) This instruction is valid for Product Certification model codes E1, E2, E3, E5, E6, E7, KA, KB, KC, and KD. S-12

Manual Supplement Rosemount 5300 and 5400 Series 5. Insert the EMC Board gently into the compartment ensuring that the contact pins are properly attached to the Barrier Board. EMC Board Contacts for the EMC Board Contact pins Barrier Board 6. Insert the into the compartment. EMC Board Contact pins for the 7. Make sure that the is properly attached to the contact pins on the EMC Board. 8. Secure the /EMC Board with the two screws. Tighten by hand. 9. Remove the cover from the tank seal. Mount the transmitter head on the tank seal and make sure the nut is properly tightened. Nut 50 mm (Rosemount 5300) Nut 60 mm (Rosemount 5400) 10. Connect signal wires and grounding. S-13

Rosemount 5300 and 5400 Series Manual Supplement 11. Tighten the cover to the terminal compartment and tighten the cable glands, making sure that the cover is secured to meet explosion-proof requirements. For ATEX, IECEx, and NEPSI installations, lock the cover with the locking screw. Locking Screw. To lock: unscrew until it locks against cover. 12. Power up the transmitter and verify proper operation. S-14

Manual Supplement Rosemount 5300 and 5400 Series Exchanging the Barrier Board This section describes how to change the Barrier Board for Rosemount 5300 and Rosemount 5400 Series transmitters (1). To change the Barrier Board do the following: 1. Remove the transmitter head (see Removing the Transmitter Head on page S-4). 2. Remove the two screws that hold the. 3. Pull the and the EMC Board out of the compartment. EMC Board Barrier Board 4. Remove the two screws that hold the Barrier Board. Barrier Board (1) This instruction is valid for Product Certification model codes E1, E2, E3, E5, E6, E7, KA, KB, KC, and KD. S-15

Rosemount 5300 and 5400 Series Manual Supplement 5. Disconnect the cable from the Barrier Board. Disconnect cable 6. Verify that the Part Number of the Barrier Board is correct, see Part Number References on page S-19. Label with Part Number 7. Connect the Barrier Board cable to the new Barrier Board. It will only fit in the correct polarity. Make sure the Barrier Board cable is correctly routed and not jammed. Barrier Board cable S-16

Manual Supplement Rosemount 5300 and 5400 Series 8. Tighten the screws. The two screws connect the Barrier Board to ground and are critical for the assembly to be explosionproof/flameproof. Make sure the screws are fully tightened. 9. Insert the EMC Board gently into the compartment ensuring that the contact pins are properly attached to the Barrier Board. EMC Board Contacts for the EMC Board Contact pins Barrier Board 10. Insert the into the compartment. EMC Board Contact pins for the 11. Make sure that the is properly attached to the contact pins on the EMC Board. 12. Secure the /EMC Board with the two screws. Tighten by hand. 13. Remove the cover from the tank seal. Mount the transmitter head on the tank seal and make sure the nut is properly tightened. Nut 50 mm (Rosemount 5300) Nut 60 mm (Rosemount 5400) 14. Connect signal wires and grounding. S-17

Rosemount 5300 and 5400 Series Manual Supplement 15. Tighten the cover to the terminal compartment and tighten the cable glands, making sure that the cover is secured to meet explosion-proof requirements. For ATEX, IECEx, and NEPSI installations, lock the cover with the locking screw. Locking Screw To lock: unscrew until it locks against cover. 16. Power up the transmitter and verify proper operation. S-18

Manual Supplement Rosemount 5300 and 5400 Series PART NUMBER REFERENCES For verification of the Part Number of the EMC Board, Barrier Board, or, use the table below. Previously used Part Number New Part Number EMC Board 9240030-516 9240030-529 EMC Board N/A 9240030-549 FOUNDATION Fieldbus Barrier Board 9240030-517 9240030-544 HART Std. (1) 05400-0601-0001 05400-7004-0001 HART Transient 05400-0601-0002 05400-7004-0006 FOUNDATION 05400-0601-0003 05400-7004-0003 Fieldbus Std. (1) FOUNDATION Fieldbus 05400-0601-0004 05400-7004-0004 Transient (1) FISCO (1) 05400-0601-0005 05400-7004-0005 (1) For a transition period, both part numbers are valid and will be delivered from factory. Parts with Previously used Part Number and parts with New Part Number are identical; the only change is in label design. S-19

Rosemount 5300 and 5400 Series Manual Supplement The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. HART is a registered trademark of the HART Communication Foundation. FOUNDATION is a trademark of the Fieldbus Foundation. All other marks are the property of their respective owners. 2011 Rosemount Inc. All rights reserved. Standard Terms and Conditions of Sale can be found at http://www.rosemount.com/terms_of_sale/. Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906-8888 F (952) 949-7001 www.rosemount.com Emerson Process Management Shared Services Ltd. Heath Place Bognor Regis West Sussex PO22 9SH England Tel 44 (1243) 863121 Fax 44 (1243) 867554 Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 Tel (65) 6777-8211 Fax (65) 6777-0947 Enquiries@AP.Emersonprocess.com 00809-0200-4026 Rev BB, 03/11