Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection



Similar documents
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Electrical connection

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

LUT Luminescence scanners: Seeing what no-one else can

W150: Miniature photoelectric switch series with completely integrated electronics

RY2 miniature industrial relays

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Measuring Sensors PRODUCT DESCRIPTION

Color Mark Sensor with Red or Green LED E3S-VS

intelligent solutions

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

CONFIGURABLE SAFETY RELAYS

Barcode Reader Series BCL 31, BCL 32, BCL 34

photoelectric highlights

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Universal Voltage Terminal Photoelectric E3JM

CONFIGURABLE SAFETY RELAYS

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Cross-beam scanning system to detect slim objects. 100 mm in

38 Series - Relay interface modules A

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

technical data (according to IEC )

38 Series - Relay interface modules A

Digital display DA 48

HERZ-Thermal Actuators

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Pluggable interface relays CR-P Pcb relays

Electric Rotary Actuator - On/Off or programmable control actuator

W 36: Mastering complex tasks reliably

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Cable Plug acc. to DIN EN , Form A

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Inductive sensor NI10-M18-Y1X-H1141

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

How To Use A Flowmeter

650W Single Output Power Supply

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Fast, reliable, ultra-precise. My-Com precision switches.

Inductive Proximity Sensors

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

W 160: Miniature series for optimum solutions

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Adjustment functions for both span and shift have been incorporated

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Panel Meters and Controllers Modular Panel Meter Type EDM 35

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

Three-phase monitoring relay CM-PFE

Control Devices Catalogue. Control Devices. Preferred and Standard Products

E-STOP relays, safety gate monitors

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Safety Relays ESM/ESM-F

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Preset Counter signo 721

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

SKR - industry relay

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Safety technique. Emergency stop module BO 5988 safemaster

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Relés e Contatores de Estado Sólido SIRIUS

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

Combi switchbox with integrated 3/2 way pilot valve

is then retained absolutely without interruption.

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Guideline Laser Series

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

Smart Sensing Solutions Since 1954

Electronic Pressure Switch EDS 300

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

Power Supplies 3. SDN-P DIN Rail Series

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

FP2 Relay. The Best Relaytion

New XUY roller sensors

ACS-30-EU-EMDR-10-MOD

BOS 73K... BOS 74K...

Transcription:

Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching! Universal connection via terminals! Additional plug-in time module! Integrated optics heating A B C D E Removable lid cheese head screw DIN 6912 M5x16 (machined) Optical axis Indicator diodes Device fixture M6x9 Device fixture M6x12 ISO 9001 Electrical connection We reserve the right to make changes 78_a01e.fm IEC 60947... IEC 60947... IP 65 Accessories: (available separately)! Mounting systems (BT 16, UMS 78)! Fastening adapter BT 08! Diaphragm BL 04! Time module transient pulses ZK 7810! Time module slow operation/release ZK 7820! Alignment aid ARH 2 Transmitter Receiver Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730 www.leuze.de LS 78/24 R - 04

LS 78 Specifications Optical data Typ. operating range limit 1) Operating range 2) Light source Wavelength Timing Sensor switching frequency Sensor response time Delay before start-up Electrical data Operating voltage U B Power consumption Residual ripple Bias current 180m 120m LED(modulated light) 880nm 100Hz (PNP/NPN) 20Hz (relay) 5ms (PNP/NPN) approx. 25ms (relay) 200ms 12 30VDC approx. 600mW (PNP/NPN) approx. 3.5VA (relay) 15% of U B 70mA (PNP/NPN) max. 120mA (relay) PNP/NPN transistor output or relay Light/dark switching through sliding switch (U B -2V)/ 2V (PNP/NPN) max. 100mA (PNP/NPN) max. 240VAC with resistive load max. 2.5AAC with resistive load Switching output Function characteristics Signal voltage high/low Output current Switching voltage, relay Switching current, relay Indicators LED red light path interrupted LED green light path free Mechanical data Housing Weight Optics Connection type Environmental data Ambient temp. (operation/storage) 3) Protective circuit 4) VDE safety class Protection class IP 65 LED class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 Options De-humidifying system diecast aluminium transmitter 600g, receiver 600g glass lens screw terminals -20 C +60 C/-30 C +70 C 1, 2, 3 I, all-insulated to prevent condensation on the optics due to temperature changes 1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) -30 C with operating voltage continuously applied 4) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection Order guide Designation Part No. Transmitter and receiver LS 78/24 R Transmitter LS 78/2 SE 500 00229 Receiver LS 78/24 RE 500 06684 Tables Diagrams Remarks The standard devices are expandable through plug-in time modules:! Time module ZK 7810 (transient pulses), slow operation and pulse length adjustable from 0.1s 5s.! Time module ZK 7820 (slow operation and release), slow operation and release separately adjustable from 0.2s 10s. See figure for adjustment: transient pulses slow operation and slow release drop-out pick-up LS 78/24 R - 04 0512

RK 78 Energetic diffuse reflection light scanner Dimensioned drawing 0 0.8m 115/230 V AC! AC voltage 115/230V! Relay output! Light/dark switching! Universal connection via terminals! Additional plug-in time module A B C D E F Removable lid cheese head screw DIN 6912 M5x16 (machined) Sensitivity adjustment Optical axis Indicator diodes Device fixture M6x9 Device fixture M6x12 ISO 9001 Electrical connection We reserve the right to make changes 78_c01e.fm IEC 60947... IEC 60947... IP 67 Accessories: (available separately)! Mounting systems (BT 16, UMS 78)! Fastening adapter BT 08! Diaphragm BL 04! Time module transient pulses ZK 7810! Time module slow operation and release ZK 7820! Alignment aid ARH 2 Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730 www.leuze.de RK 78/7-800 - 04

RK 78 Specifications Optical data Scanning range (white 90%) 1) 0 800mm Adjustment range 5 100% Light source LED (modulated light) Wavelength 880nm Timing Sensor switching frequency 20Hz Sensor response time approx. 25ms Delay before start-up 200ms Electrical data Operating voltage U B 115/230VAC Power consumption approx. 3.5VA Residual ripple 15% of U B Bias current max. 120mA Switching output relay: 1 change-over contact Function characteristics Light/dark switching through sliding switch Switching voltage, relay max. 240VAC with resistive load Switching current, relay max. 2.5AAC with resistive load Indicators LED red light path interrupted Mechanical data Housing diecast aluminium Weight transmitter 600g, receiver 600g Optics glass lens Connection type screw terminals Environmental data Ambient temp. (operation/storage) 2) -20 C +60 C/-30 C +70 C Protective circuit 3) 1, 2, 3 VDE safety class I, all-insulated Protection class IP 65 LED class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 Options De-humidifying system to prevent condensation on the optics due to temperature changes 1) Scanning range: recommended range with performance reserve 2) -30 C with operating voltage continuously applied 3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection Tables Diagrams Order guide Designation Part No. Energetic diffuse reflection light scanner RK 78/7-800 500 00452 Remarks The standard devices are expandable through plug-in time modules:! Time module ZK 7810 (transient pulses), slow operation and pulse length adjustable from 0.1s 5s.! Time module ZK 7820 (slow operation and release), slow operation and release separately adjustable from 0.2s 10s. See figure for adjustment: transient pulses slow operation and slow release drop-out pick-up RK 78/7-800 - 04 0512

SLS 78 Protective throughbeam photoelectric sensors Dimensioned drawing 0 150m 24 V DC BWS Typ 2 HANNOVER SACHSEN-ANHALT! Activation input for testing and interlinking! Connection via M12 connector! Integrated optics heating A B C D E Transmitter/receiver Optical axis Indicator diodes Device fixture M6x9 Device fixture M6x12 ISO 9001 Electrical connection We reserve the right to make changes 78_a03e.fm IEC 60947... IEC 60947... IP 65 Accessories: (available separately)! Mounting systems (BT 16, UMS 78)! Alignment aid ARH 2! M12 connectors (KD )! Test-monitoring units: - available only from Leuze lumiflex SLSS 78M-1720-T2-45 SLSE 78 M/P-1730-T2-41 Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730 www.leuze.de SLSS 78 M - 04 SLSE 78 M/P - 04

SLS 78 Specifications Optical data Typ. operating range limit 1) 0 150m Operating range 2) 0 120m Light source LED (modulated light) Wavelength 880nm Timing Switching frequency 300Hz Response time 1.7ms Delay before start-up 200ms Input pulse min. 1.7ms Electrical data Operating voltage U B 24VDC ± 20% Residual ripple 15% of U B Bias current receiver 35mA transmitter 60mA Switching output PNP transistor output Function characteristics light switching Signal voltage high/low (U B -2V)/ 2V Output current max. 200mA Indicators Receiver LED red light path interrupted LED green light path free LED green flashing light path free, no performance reserve Transmitter LED yellow transmitter ON Mechanical data Housing diecast aluminium Optics glass, eff. angle of radiation ± 4 acc. to pren 50100-2 Weight 463g Connection type M12 connector, 4-pin Environmental data Ambient temp. (operation/storage) -25 C +60 C/-30 C +70 C VDE safety class III Protective circuit 3) 1, 2, 3 Protection class IP 65 LED class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 Options Activation input activ Transmitter active/not active 8V/ 2V or not connected Activation/disable delay 400µs Input resistance 4.7kΩ ±10% 1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection Tables Diagrams Order guide Designation Part No. Transmitter and receiver SLS 78M/P-1730-T2-4 Transmitter SLSS 78M-1720-T2-45 500 29536 Receiver SLSE 78 M/P-1730-T2-41 500 80323 Remarks The protective throughbeam photoelectric sensor is a contactless active protective device only in connection with a safety-relevant control system, in which the cyclical testing of transmitter and receiver is carried out according to EN 61496-1, category 2 (testing). The power supply unit used to operate the photoelectric sensor has to be able to compensate for changes and interruptions of the supply voltage acc. to EN 61496-1. Minimum blackening object: Ø30mm. SLSS 78 M - 04 0512 SLSE 78 M/P - 04

LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 115/230 V AC 24/48 V AC! AC voltage 115/230V and 24/48V! Light/dark switching! Universal connection via terminals! Additional plug-in time module A B C D E Removable lid cheese head screw DIN 6912 M5x16 (machined) Optical axis Indicator diodes Device fixture M6x9 Device fixture M6x12 ISO 9001 Electrical connection We reserve the right to make changes 78_a02e.fm IEC 60947... IEC 60947... IP 65 Accessories: (available separately)! Mounting systems (BT 16, UMS 78)! Alignment aid ARH 2! Test monitoring unit: - TNT 32 (Part No. 500 20476) - TNT 33 (Part No. 500 28158) - TNT 34 (Part No. 500 81023) Transmitter Receiver Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730 www.leuze.de LS 78/7-04

LS 78 Specifications Optical data Typ. operating range limit 1) 180m Operating range 2) 120m Light source LED (modulated light) Wavelength 880 nm Timing Sensor switching frequency 20Hz (relay) Sensor response time approx. 25ms (relay) Delay before start-up 200ms Electrical data Operating voltage U B 115/230VAC, 24/48VAC Power consumption approx. 3.5VA (relay) Bias current max. 120mA (relay) Switching output relay: 1 change-over contact Function characteristics Light/dark switching through sliding switch Switching voltage, relay max. 240VAC with resistive load Switching current, relay max. 2.5AAC with resistive load Indicators LED red light path interrupted LED green light path free Mechanical data Housing diecast aluminium Weight transmitter 600g, receiver 600g Optics glass lens Connection type screw terminals Environmental data Ambient temp. (operation/storage) 3) -20 C +60 C/-30 C +70 C Protective circuit 4) 1, 2, 3 VDE safety class I, all-insulated Protection class IP 65 LED class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 Options De-humidifying system to prevent condensation on the optics due to temperature changes 1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) -30 C with operating voltage continuously applied 4) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection Tables Diagrams Order guide Selection table Equipment # Order code " LS 78/7 Part No. 500 00235 (Tr) Part No. 500 00240 (Re) LS 78/7 24/48 V Part No. 500 25233 (Tr) Part No. 500 25232 (Re) Housing metal!! Typ. operating range limit 180m!! Connection terminals!! Features Voltage supply 115/230VAC! 24/48VAC! Switching output relay!! Time modules ZK 7810, ZK 7820 retrofittable!! Remarks The standard devices (see table) are expandable through plug-in time modules:! Time module ZK 7810 (transient pulses), slow operation and pulse length adjustable from 0.1s 5s.! Time module ZK 7820 (slow operation and release), slow operation and release separately adjustable from 0.2s 10s. See figure for adjustment: transient pulses slow operation and slow release drop-out pick-up LS 78/7-04 0512

FRK 78 Diffuse reflection light scanner with background suppression Dimensioned drawing 50 800mm 12-30 V DC 115/230 V AC 24/48 V AC! With PNP switching output and/or relay outputs! Light/dark switching in each device! Universal connection via terminals! Additional plug-in time module A B C D E Removable lid cheese head screw DIN 6912 M5x16 (machined) Optical axis Indicator diodes Device fixture M6x9 Device fixture M6x12 Preferred entry direction for objects " + # + $ ISO 9001 Electrical connection We reserve the right to make changes 78_d01e.fm IEC 60947... IEC 60947... IP 67 Accessories: (available separately)! Mounting systems (BT 16, UMS 78)! Fastening adapter BT 08! Diaphragm BL 04! Time module transient pulses ZK 7810! Time module slow operation and release ZK 7820! Alignment aid ARH 2 Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730 www.leuze.de FRK 78/4 R-800, FRK 78/7-800 - 04 FRK 78/7-800-24-48 V - 04

FRK 78 Specifications Optical data Scanning range 1) Adjustment range Light source Wavelength Timing Sensor switching frequency Sensor response time Delay before start-up Electrical data Operating voltage U B Power consumption Residual ripple Bias current 50 800mm 140 1000mm LED (modulated light) 880nm 100Hz (PNP) 20Hz (relay) 5ms (PNP) approx. 25ms (relay) 200ms Switching output Function characteristics Signal voltage high/low Output current Switching voltage, relay Switching current, relay Indicators LED red light path interrupted Mechanical data Housing Weight Optics Connection type Environmental data Ambient temp. (operation/storage) 2) Protective circuit 3) VDE safety class 4) Protection class IP 65 LED class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 Options De-humidifying system 1) Scanning range: adjustable through spindle drive inside the housing 2) -30 C with operating voltage continuously applied 3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection 4) Rating voltage 250VAC Order guide Selection table 12 30VDC, 115/230VAC, 24/48VAC approx. 600mW (PNP) approx. 3.5VA (relay) 15% of U B 70mA (PNP / NPN) max. 120mA (relay) PNP transistor output, relay: 1 change-over contact Light/dark switching through sliding switch (U B - 2V)/ 2V (PNP) max. 100mA (PNP) max. 240VAC with resistive load max. 2.5AAC with resistive load diecast aluminium transmitter 600g, receiver 600g glass lens screw terminals -20 C +60 C/-30 C +70 C 1, 2, 3 I, all-insulated to prevent condensation on the optics due to temperature changes Order code % FRK 78/4 R-800 Part No. 500 00590 FRK 78/7-800 Part No. 500 00591 FRK 78/7-800-24-48 V Part No. 500 00365 Equipment& Housing metal!!! Scanning range 800mm!!! Connection terminals!!! Features Voltage supply 12 30VDC!! 115/230VAC! 24/48VAC! Switching output PNP! relay!!! Time modules ZK 7810, ZK 7820 retrofittable!!! Tables Diagrams Remarks Operation without relay through splitting of bridge "B" (FRK 78/4 R-800). The standard devices (see table) are expandable through plug-in time modules:! Time module ZK 7810 (transient pulses), slow operation and pulse length adjustable from 0.1s 5s.! Time module ZK 7820 (slow operation and release), slow operation and release separately adjustable from 0.2s 10s. See figure for adjustment: drop-out transient pulses slow operation and slow release pick-up FRK 78/4 R-800, FRK 78/7-800 - 04 0512 FRK 78/7-800-24-48 V - 04