White paper. Shielded or unshielded network cables A matter of choice, electromagnetic environment and compatibility



Similar documents
Course Catalog Axis Communications Academy

Bringing open IP benefits to physical access control AXIS A1001 Network Door Controller

ARTICLE. 10 reasons to switch to IP-based video

White paper. Lightfinder. Outstanding performance in difficult light conditions

Axis Exam Preparation Guide

INSTALLATION GUIDE. AXIS T8133 Midspan 30W

White paper. IP opens doors to a new world of physical access control

with Component Rating A Simple Perspective

Axis Mobile Streaming

WHITE PAPER. P-Iris. New iris control improves image quality in megapixel and HDTV network cameras.

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

guide Axis Camera Families for Autodesk Revit

Questions and answers

Axis IP surveillance. Endless possibilities for video surveillance.

ARTICLE. Sound in surveillance Adding audio to your IP video solution

ARTICLE. Which has better zoom: 18x or 36x?

Whitepaper. Image stabilization improving camera usability

White paper. Axis Video Analytics. Enhancing video surveillance efficiency

OptimizedIR in Axis cameras

Transportation. The road to smarter traffic monitoring with Axis network video solutions.

Axis video encoders. Where analog and network video meet.

30 In Compliance October

ARTICLE. Image quality: Usability is the real issue How to select the right camera system.

The impact of the New EMC Directive 2004/108/EC

White paper. Video encoders - brings the benefits of IP surveillance to analog systems

EMC Standards: Standards of good EMC engineering

Frequently Asked Questions

White paper. Axis Video Analytics. Enhancing video surveillance efficiency

Security & Surveillance Cabling Systems

Data Centers. Defense in depth. Network video protection for data centers.

Media Conversion in Video Security and Surveillance Systems

Axis Thermal Network Cameras High-quality detection in dark and challenging conditions

Accelerating solution sales. Channel Partner Program.

White paper. In the best of light The challenges of minimum illumination

White paper. CCD and CMOS sensor technology Technical white paper

AXIS 291 1U Video Server Rack Installation Guide

AXIS T81B22 DC 30W Midspan

White paper. Sharpdome. Sharp images on every level

Education. Educated security solutions. Secure your school or university with Axis network video solutions.

Streamlining software integration. Application Development Partner Program.

Axis network cameras A wide portfolio of products for professional video surveillance.

Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

G019.A (4/99) UNDERSTANDING COMMON MODE NOISE

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

EMC Safety switches January 2008

KVM - DVI, USB 2.0, Cat 5 Extender

Ethernet Patch Cord Wiring

USB Rover port USB m Cat 5 Extender. User Guide

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Data Communications Competence Center

Grounding Demystified

Fiber s Role in the Video Security & Surveillance Network. Curt Carlson Product Manager Transition Networks

MDI/MDIX) FEP-32008T-3

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

Chapter 4 Connecting to the Internet through an ISP

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

Electromagnetic Compatibility Considerations for Switching Power Supplies

How to Choose the Right Cable Category

Industrial Ethernet The Perfect Cable for an Imperfect Environment

White paper. Latency in live network video surveillance

Large surveillance systems

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

White paper. SIP An introduction

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

AXIS 241Q/S Blade - Rack Solution Installation Guide

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

aseries A13B Mini Bullet Camera User Manual

EMI in Electric Vehicles

Structured Cabling, Earthing & Equipotential Bonding

STRUCTURED CABLING SYSTEMS

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

Electromagnetic (EMI) shielding

Growing our business. Together. Leveraging Axis Channel Partner Program benefits in North America.

PRO 5000 CPE 1D Quick Installation Guide

Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables.

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

Understanding SMD Power Inductors. Application Note. July 2011

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

An extended EMC study of an electrical powertrain for transportation systems

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

White paper. HDTV (High Definition Television) and video surveillance

3.5 mm Audio Jack. Manual innoxplore ix B24 A2DP Stereo Bluetooth Audio Adapter Dongle 3.5mm Audio Jack [ix B24] Contents

10/100/1000 Base-T to Gigabit Fiber Media Converter

Balanced vs. Unbalanced Audio Interconnections

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

8-Port PoE Network Switch

W O R L D C L A S S H I F I

Radiometrics Guide to FCC & Canada Compliance. for Unintentional Radiators

Transcription:

White paper Shielded or unshielded network cables A matter of choice, electromagnetic environment and compatibility

Table of contents 1. Introduction 3 2. Shielded versus unshielded network cables 3 3. Two digital device classes 4 4. Immunity 4 5. Shielded cables or unshielded cables with axis network cameras 4

1. Introduction All electric and electronic devices emit electromagnetic energy, also referred to as radio frequency emission or RF emission. RF emissions are a byproduct of electrical or magnetic activity. Unfortunately, the emissions from one device can interfere with other devices and could potentially cause problems. Interference can lead to data loss, picture quality degradation on monitors and cameras and can cause other equipment to malfunction. This is generally titled electromagnetic interference or EMI problems. Electromagnetic Compatibility (EMC) refers to the ability of equipment to function satisfactorily without disturbing other equipment in that environment. For example, any system connected to the alternating current (AC) mains power line must be immune to transient surges; the degree of immunity depends on the application. EMC requirements concern two basic concepts: emissions and immunity (susceptibility). Immunity is a measure of how good a system is at rejecting interference from other devices. Both emission and immunity are factors that need to be taken into consideration before determining how a product shall be installed in an existing environment. 2. Shielded versus unshielded network cables Lately, debate has arisen on the advantages and disadvantages of shielded twisted-pair (STP) cables and unshielded twisted-pair (UTP) cables. Though STP cables and UTP cables are inherently different in design and manufacture, their purpose should be the same, which is to provide reliable connectivity of electronic equipment. In this paper, we make the simplification to allow different types of shielded or screened cables (FTP, S/FTP, SF/UTP) to be addressed as Shielded Twisted Pair Cable or STP. STP UTP The shield works as a guard and drains induced current surges to earth via PoE adapter or the switch STP cables have additional shielding material that is used to reduce external interference. The shield also reduces the emission at any point in the path of the cable. UTP cables provide much less protection against such interference and the performance is often degraded when interferences or disturbances are present. Both types of cables, however, have some protection to interference due to the twisted pair design of the conductors. The drawback of STP cables is that they will increase the total cost of an installation. STP cables are more expensive due to the shielding, which is an additional material that goes into every meter of the cable. The shielding also makes the cable heavier and stiffer. Thus, it is more difficult to handle. 3

3. Two digital device classes Whether a product is tested to Class A or B limits for emissions is determined by the environment in which the product will be used according to the following definitions. Class A Class A digital devices are marketed for use in a commercial, industrial or business environment. Since the product is intended for a commercial market, the emissions requirements are less stringent than Class B (residential) devices. Class B Class B digital devices are marketed for use in residential areas. As such, they are tested to comply with harder emission requirements than Class A devices. In fact, FCC encourages manufacturers to comply with Class B limits even if the product is marketed for use in a commercial, industrial or business environment. Note that the FCC rules according to part 15, subpart B, Class A and Class B digital devices refer to RF emission only. A Class A product has lower requirements for RF emission due to the higher level of radio frequency interference already present in a commercial, industrial or business environment than a Class B product, which is intended for use in a residential environment. 4. Immunity Immunity is a measure of the ability of electronic products to tolerate the influence of electrical energy (radiated or conducted) from other electronic products and electromagnetic phenomena. The requirements for a product to withstand electrical disturbances or interference are the opposite of RF emission requirements. That is, the immunity requirements are higher in an outdoor, industrial or similar environment, than in a residential environment. 5. Shielded cables or unshielded cables with Axis network cameras Recently, a selected range of Axis products has undergone extensive RF-emission tests with the result that the user can choose between using unshielded, UTP, network cables and fulfill the FCC Class A RF-emission limits, or using shielded, STP, network cables and fulfill the FCC Class B RF-emission limits. Our recommendation is to deploy an STP network cable in demanding electrical environments. Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable. It is also mandatory to use an STP cable where the camera is used outdoors or where the network cable is routed outdoors. Most indoor surveillance deployments are done with an unshielded twisted-pair cable and that will be sufficient to fulfill the regulatory requirements for the US market. The UTP network cable will provide lower cable costs. Since it is less bulky and allows a simpler termination of the connector, it is also easier to handle. These may all be principal factors for the customer. 4

www.axis.com 47113/EN/R1/1203 About Axis Communications As the market leader in network video, Axis is leading the way to a smarter, safer, more secure world driving the shift from analog to digital video surveillance. Offering network video solutions for professional installations, Axis products and solutions are based on an innovative, open technology platform. Axis has more than 1,000 dedicated employees in 40 locations around the world and cooperates with partners covering 179 countries. Founded in 1984, Axis is a Sweden-based IT company listed on NASDAQ OMX Stockholm under the ticker AXIS. For more information about Axis, please visit our website www.axis.com 2012 Axis Communications AB. AXIS COMMUNICATIONS, AXIS, ETRAX, ARTPEC and VAPIX are registered trademarks or trademark applications of Axis AB in various jurisdictions. All other company names and products are trademarks or registered trademarks of their respective companies. We reserve the right to introduce modifications without notice.