Open System Architecture

Similar documents
IT Cabling Solutions

How to Choose the Right Cable Category

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

SHEET 5 CABLE TELEVISION SYSTEM

Accelerating Light. Copper Cabling Solutions. Category 6A

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Copper Patch Cords. Impact On Network Performance and Reliability

The High Cost of a Low-Cost Cable Certification Tester

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

Data Communications Competence Center

Overcoming OM3 Performance Challenges

Enhanced Category 5 Cabling System Engineering for Performance

Cabling Standards Update 2014

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

TIA Fiber Optics LAN Section (FOLS) LAN Standards, News & Trends Report

Upgrading Path to High Speed Fiber Optic Networks

GigaSPEED X10D Solution How

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements

Security & Surveillance Cabling Systems

CCNA Discovery Chapter Four

Direct Attach Cable with Micro Coaxial Wire for Data Center

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk


STATE OF NEVADA Department of Administration Division of Human Resource Management CLASS SPECIFICATION

EECC694 - Shaaban. Transmission Channel

24 GHz Point-to-Point 1.4+ Gbps Radio. Datasheet. Model: AF24. High Performance Wireless Backhaul. Long Range of 13+ km

Network Engineers Everywhere:

Safety & Performance in the Wire and Cable Industry

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

Innovative Connectivity Solution for Maximum Performance and Security

TECHNICAL NOTE 7-1. ARCNET Cable Length vs. Number of Nodes for the HYC9088 in Coaxial Bus Topology By: Daniel Kilcourse May 1991.

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Panduit 28 AWG Patch Cords Installation Guideline

Obsolete Fiber Technology? Not in my Data Center!

Chapter 4 Connecting to the Internet through an ISP

SYSTIMAX Copper Solutions Designed for the Digital Generation

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Characterization of a new copper cable for next generation DSL systems

Connecting Wireless. Distributed Antenna System Cable & Connectivity

Fiber Systems. Best Practices for Ensuring Polarity of Array-Based Fiber Optic Channels

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Leviton Network Solutions Certified Contractors

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Structured and Point to Point Network Cabling for Industrial Automation

DATA CENTRES POWERED BY EXCEL

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

VIDEO SURVEILLANCE OVER UTP WHITE PAPER INTRODUCING VIPER VIDEO SURVEILLANCE

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

PANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Total Solutions Verification

Innovative cable technologies Business Unit Telecommunication Systems

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Category 6 Cabling Questions and Answers

with Component Rating A Simple Perspective

Nexus Technology Review -- Exhibit A

Uniprise Solutions COAX 101. White Paper.

Broadband 101: Installation and Testing

TENDER: Tf{/ A

Make your business EXCEL with technology solutions provided by Excel Communications Worldwide, Inc.

(Refer Slide Time: 2:10)

Broadband access. Nils Holte, NTNU. NTNU Department of Telecommunications Kursdagene ved NTNU, Digitale telenett, 9. januar

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Networks. The two main network types are: Peer networks

Component 4: Introduction to Information and Computer Science

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters

IPTV over Fiber Optics for CPE Installers

SPEAKER WIRE BY JOHN F. ALLEN

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Polymer Coated Fiber Cable (PCF)

Copper Cabling Troubleshooting Handbook

why fixed.plan? We only connect to Tier 1 partners, including Openreach, BT and Talk Talk Business, ensuring a robust and reliable service.

Media Conversion in Video Security and Surveillance Systems

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

The UlTimaTe in PremiUm ConneCTion

Transcription:

Open System Architecture

What is Open System Architecture? If you are installing a Category 5e, 6 or 6A infrastructure, there is a sizeable selection of well know products available. What makes one product a wiser choice than another? Which one offers maximum performance, while also providing the best value? Should you buy the heavily marketed closed brand solution that touts unmatched performance or should you pick and choose the products that best meet your specific needs? If you do the latter, what kind of performance can you expect to get? The closed solutions appear to offer the best performance. But, they are also asking a premium for that performance. If you own this project, you want the best value possible. You want high performance, without the high price. The purpose of this paper is to illustrate why open system architecture, a standards based network solution approach, is a viable alternative to those closed solutions. This paper will also provide examples of the exceptional performance delivered by an open system architecture solution that includes HCA brand Category 6 cable from Hitachi Cable America.

Open System Architecture vs Closed Solutions In network infrastructure, the term open system architecture refers to the practice of using virtually any combination of standards-compliant cable and connective hardware in the design of the network. The standard, ANSI/TIA-568-C.1, dictates the performance requirements of the network components to ensure that they will accommodate the applications that were designed to operate over them. By employing the open system architecture philosophy, the end user has the freedom to choose the products that best meet their specific needs. They can then be confident that the solution they chose will support all applications designed to operate over that solution. Just like a standard light bulb will fit into any lamp and work when you flip the switch, so will the network perform when you use components that meet or exceed the standards. Of course there are also different levels of quality and performance to choose from in the market place. Certainly a wise choice, especially when it comes to cable for the open system architecture, is to select a company that offers guaranteed performance, a substantial warranty, such as a lifetime warranty, and has sufficient personnel, both internally and externally, to properly support the customer. If an issue arises, it s good to have quick and easy access to the manufacturer. Other items that can contribute to confidence in a product s selection are if it is manufactured in the U.S. and if the company makes its facility accessible to visitors. Generally, companies that build a quality product are proud to show customers how they do it. Since a network infrastructure can be a significant investment, typically in the thousands or even millions of dollars, knowing the origin of the products and being familiar with their manufacturers could very likely influence your decision when selecting components. Closed solutions, ones in which a specific cable and connectivity manufacturer must be used in order to obtain a warranty, are typically marketed as providing better performance than standards-based solutions. This may or may not be the case. These closed solutions may involve the components from two companies or a single company. Often, a connectivity manufacturer aligns with a cable manufacturer. In some instances all materials come from one company, or at least, have one company s name printed on them. Few companies actually make both the cable and connective hardware themselves. Closed solutions offered by a single company or from a collaborative effort between companies are not new. They have been around for a number of years. And, virtually all of them tout some advantage that its solution offers over the others. But, how can you really tell which one is the best? How much is fact and how much is hype? In fact, just recently, two solutions, each comprised of a connectivity manufacturer and a cable manufacturer, broke off their longterm relationships and switched partners. Was this done to provide a better product to the customer? Was it done because of a new corporate sales strategy? Regardless, when two companies market a closed solution jointly, it may have more to do with their sales channels than their quest for higher performance. These are just some of the items to consider when choosing materials. At Hitachi Cable America, we believe the best method for selecting the appropriate products for an infrastructure is to evaluate the performance, warranty and overall value that the individual components offer. With that information, you can then build the best infrastructure for your company. An open system architecture solution offers users the freedom to chose the materials that best meet their needs.

Warranty Every end-user wants to be certain that the products they have chosen will be backed by a meaningful warranty. Most closed solutions offer a warranty carried by one of the companies in the solution, usually the connectivity manufacturer, and it covers the entire solution. The length of these warranties may be 15 or 25 years. These warranties are only available through certified installers. So, in order to receive a warranty, the installation must be performed by an installer that has been certified by the solution manufacturer(s). This ensures that the work is done in an acceptable manner. This is, unquestionably, a good practice. Hitachi Cable America offers a lifetime warranty through its network of certified installers. This warranty lasts as long as the owner occupies the facility. Hitachi Cable America, however, also permits the warranty to be transferred to a new owner. Testing of the network is required, but the ability to transfer the warranty can be of great value to a company that may choose to lease out their current space. The closed solution warranties can be comprehensive, but they can also be very restrictive. Virtually all closed solution warranties restrict future moves, adds and changes to the network in ways that are not always in the best interest of the end user. For example, representatives from some of the closed solution companies have been known to threaten end-users by telling them that if they integrate non-solution products into their solution, they could place the warranty for the entire infrastructure in jeopardy. One could argue that this restriction helps keep inferior products and or installers from interacting with the warranted products. It can also help exclude competition and ensure that the end user only buys products from their solution. Also, as part of their installer certification process, some companies, such as Hitachi Cable America, offer training programs that can be very educational. Hitachi Cable America s training programs are accredited by BICSI (Building Industry Consultant Services International), so those who require credits to maintain a BICSI certification can receive them by attending Hitachi Cable America s training programs. Hitachi Cable America s facility is located in Manchester, New Hampshire. All copper premise and fiber optic cables are manufactured there and facility tours are available. If you need direct support from the manufacturer, it s available directly from Hitachi Cable America. If you have questions about Hitachi Cable America products or our Lifetime warranty, you can call Hitachi Cable America directly. When it comes to a warranty, no company offers a warranty more comprehensive than Hitachi Cable America s Lifetime Warranty. Performance Is performance of the network infrastructure important? You bet it is. Studies have indicated that approximately 50% of network throughput problems are related to the network infrastructure. So, when trying to obtain the best value for the investment, it is very important to select high quality, high performance products. The purveyors of closed solutions contend that only their solutions can provide exceptional performance. The performance they offer may be good, but is it measurably better than that which can be obtained by combining a leading cable manufacturer and a leading connectivity brand? Recently, Hitachi Cable America obtained third-party testing of its HCA Category 6 PLUS cable (30025-8) and the connectivity provided by eight well-known manufacturers. The data (right) indicates that when the PLUS cable is mated to the connectivity shown, the resulting permanent link (a circuit including cable and connectors at each end) provides performance in excess of the parameters established in the ANSI /TIA-568-C.1 standard. For example, both ACRN and PSACRN, identified in the yellow boxes, demonstrate that there is significant margin over the limits in the Category 6 standard. ACRN (Attenuation-to-Crosstalk Ratio Near-end) is the relationship between a signal on a conductor and associated noise emanating from an adjacent conductor. Near-end indicates it is at the tester end of the link being tested. ACR is calculated from attenuation and NEXT (crosstalk) measurements. PSACRN is the difference between a twisted pair s attenuation and combined crosstalk from adjacent pairs. Both ACRN and PSACRN are key performance indicators in a permanent link.

If noise overcomes a signal on a conductor, it will corrupt it. Higher ACRN and PSACRN vales are desirable. Therefore, if you chose an open system architecture solution that includes the PLUS Category 6 cable form Hitachi Cable America, you will have a solution that will support all applications intended for Category 6. So, if you are seeking the best value for your infrastructure investment, it is clear that an open system architecture solution featuring cables from Hitachi Cable America will perform as well as if not better than closed solutions, offer a better warranty, and be backed by a company with over a quarter century experience making communication cables. Open system architecture solutions can be a better value and offer equal or better electrical performance than closed solutions. Hubbell & Hitachi PLUS Category 6 Cable ACR-N (db) 11.2 Frequency (MHz) 75.0 Limit (db) 28.0 PS ACR-N (db) 11.9 Frequency (MHz) 29.0 Limit (db) 38.5 HellermanTyton & Hitachi PLUS Category 6 Cable ACR-N (db) 9.1 Frequency (MHz) 162.9 Limit (db) 15.3 PS ACR-N (db) 10.4 Frequency (MHz) 94.3 Limit (db) 23.5 Leviton & Hitachi PLUS Category 6 Cable ACR-N (db) 13.8 Frequency (MHz) 181.2 Limit (db) 11.7 PS ACR-N (db) 13.1 Frequency (MHz) 240.0 Limit (db) 2.6 OCC & Hitachi PLUS Category 6 Cable ACR-N (db) 7.8 Frequency (MHz) 71.2 Limit (db) 30.0 PS ACR-N (db) 9.8 Frequency (MHz) 71.2 Limit (db) 28.0 Panduit & Hitachi PLUS Category 6 Cable ACR-N (db) 7.9 Frequency (MHz) 18.8 Limit (db) 45.9 PS ACR-N (db) 10.1 Frequency (MHz) 18.8 Limit (db) 43.5 AMP & Hitachi PLUS Category 6 Cable ACR-N (db) 8.7 Frequency (MHz) 14.8 Limit (db) 48.4 PS ACR-N (db) 10.1 Frequency (MHz) 14.8 Limit (db) 46.0 Ortonics & Hitachi PLUS Category 6 Cable ACR-N (db) 11.0 Frequency (MHz) 57.5 Limit (db) 32.0 PS ACR-N (db) 12.8 Frequency (MHz) 57.5 Limit (db) 29.5 Systimax & Hitachi PLUS Category 6 Cable ACR-N (db) 11.6 Frequency (MHz) 24.3 Limit (db) 43.0 PS ACR-N (db) 13.3 Frequency (MHz) 24.3 Limit (db) 40.6

About Hitachi Cable America For over 25-years, Hitachi Cable America has been designing and building advanced communication cables for the telecommunications industry. Located in Manchester, New Hampshire, our 300,000 square foot (91,440 sq. m.) facility produces over 4,000 different cables. Products manufactured include HCA brand high performance copper and fiber optic communication cables, as well as flat and round electronics cables, custom cables and cable assemblies. Hitachi Cable America products are used worldwide across a wide spectrum of industries, including medical, financial, manufacturing, educational, government and military. At Hitachi Cable America, maximum cable performance is our top priority. Our on-site drawing mills provide greater control of conductor diameters and the use of only high-quality insulation and jacket materials ensure optimum electrical performance as well as long-term reliability. Whether it is cable for industrial Ethernet or Infiniband, VOIP or POE+, our cables are designed to deliver maximum throughput regardless of the environment. So if you are considering Category 6A CMP cable for a data center or need an OM4 fiber link between buildings on campus, chose cables from Hitachi Cable America. Other Products from Hitachi Cable America: Copper Category 3, 5e, 6, 6A, 7 & 7A Cables Fiber Optic Cables (indoor, outdoor & armored) NanoCore Fiber Optic Cables & Assemblies Industrial Ethernet Cables Coaxial & Mini-coaxial Cables ECOFLEX Cabling System Round & Ribbon Electronic Cables Active Optical HDMI Assembly For more information about Open System Architecture or any of the products we manufacture, please contact us. 900 Holt Avenue Manchester, New Hampshire 03109 USA Tel: 603.669.4347 Sales: 800.772.0116 Fax: 603.669.9621 www.hca.hitachi-cable.com 09/13