ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Similar documents
SENSAPHONE 901 Tryens Road Aston, PA PH:

SECTION DETECTION AND ALARM

APPLICATION SUPPORT BULLETIN

Section TELEPHONE AUTOMATIC DIALER SYSTEM

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

Uninterruptible Power Supply

SMART SENSOR COLLECTION

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

1 Serial RS232 to Ethernet Adapter Installation Guide

Rack mounted telephone- and leased line modem for industrial applications

Temperature & Humidity SMS Alert Controller

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TrueAlarm Fire Alarm Systems

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

Office of Integrated Security Systems Longwood University Camera System Standards

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Technical Overview CM-2 Climate Monitor. Get yours direct at:

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

Remote Site Management Solutions

Telephone- and leased line modem for industrial applications TD-36

AC-115 Compact Networked Single Door Controller. Installation and User Manual

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

PE6108/PE6208/PE8108/PE8208

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

ORION TELECOM NETWORKS INC. T1

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

High Power Programmable DC Power Supplies PVS Series

Product Guide CM-Relay

TrueAlarm Fire Alarm Systems

How To Use A Ds6101Di On A Tv Or Tv With A Video Camera On A Network (Tivv) Or Tv (Dv) On A Computer Or Tv At A Network Or Tv On A Cell Phone Or Tv For

United Security Products Model AVD-45b Automatic Voice Dialer Installation and Instruction Manual

VALIANT COMMUNICATIONS

Overview of Cisco 2600 Series Routers

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

3500/22M Transient Data Interface

Technical Overview CM-16 Climate Monitor. Get yours direct at:

GSM home alarm system s manual

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Business/Home GSM Alarm System. Installation and User Manual

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

securityprobe 5E Standard

Emerson Smart Firewall

MAJORSINE Power Inverter

500r+ Installation and User Guide

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Loop-V4300 MINI DACS E1/ T1 CONVERTER

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

1.44 kw Programmable DC Power Supplies XLN Series

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Expansion Modules & Accessories

DC-8706K Auto Dial Alarm System

DC Electronic Loads 8500 series

Home Security Alarm System

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

IntesisBox Modbus Server SAMSUNG Air Conditioners

Repeaters and Mimics Data Sheet

MANUAL PC1000R

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

UPS Network Interface. Quick InstallationGuide

Plena Voice Alarm System. Software Manual Configuration Software

8-Port HDMI Switch USER MANUAL VS0801H

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

APPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Business/Home GSM. Alarm System(III) Installation and Users guide

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Powerware 5110 UPS User s manual

Users Manual of GSM Home Alarm System with Photo-taken

USB-500 Series Stand-Alone, Low-Cost Data Loggers

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

ADEMCO LYNXR-I Security Systems

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8

In addition to our VoiceDirector hardware products, the following SIP broadband devices are also compatible with VoiceDirector:

Business/Home. GSM Alarm system

User Manual. Humidity-Temperature Chart Recorder. Model RH520

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

DS-9500NI-ST Series NVR. Technical Specification

Transcription:

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as the Host) capable of monitoring 8 environmental input channels and 64 network IP devices, with an architecture that can accept up to 31 additional Node units to expand the system s capacity and range of monitoring. The system shall be integrated in construction and shall be installed and configured for operation by the user via Microsoft Windows -compatible ConsoleView Software provided at no additional charge. Custom voice messages for input alarms and status messages can be recorded and uploaded into the Host by the user. Input channels shall be capable of interfacing with IMS-4000 series sensors via 8 RJ-45 jacks in the Host or Node(s). Upon detection of any alarm or status change, the system shall commence alarm delivery from a contacts list associated with the particular alarm condition(s) or combination thereof, and deliver the alarm message via a custom voice message, fax, e-mail, numeric pager, alphanumeric pager, or SNMP. The voice alarm message shall be delivered in digitized human voice using messages recorded by the user. The system will continue to call telephone numbers in succession until a positive acknowledgment of the alarm message is received. Acknowledgment can be accomplished from a voice phone call, by logging in to the unit, via web page, or via SNMP management software. The system shall have a three-year warranty from the manufacturer. The system shall be a Sensaphone IMS-4000 by Phonetics, Inc. B. Standards The system shall meet FCC requirements Part 68 and Part 15, and shall be registered for direct connection to the telephone network. The system shall comply with the Telephone Consumer Act (Host). The system shall be Canadian DOC certified. C. Optional Equipment The IMS-4000 shall have the following accessories and sensors available as options: Node: IMS-4002 8 additional sensor inputs, internal & external mics, ethernet and Serial ports PowerGate: IMS-4301 8 power outlets that can be remotely controlled via e-mail or phone PowerGate2: IMS-4302 remotely switch power from 8 inputs and to 8 outlets Temperature sensors: IMS-4810, IMS-4811, IMS-4812, IMS-4813 Humidity sensors: IMS-4820, IMS-4821 Water Detection sensor: IMS-4830 External Power sensor: IMS-4840 Dry Contact sensors: IMS-4850 4-20mA sensor: IMS-4851 1

Door switch sensor: IMS-4860 Passive infrared detection sensor: IMS-4861 Smoke detector sensor: IMS-4862 II. Product A. Enclosure The IMS-4000 Host shall be designed for the following mounting configurations: 1U rack-mount Table mount Wall mount (using optional flanges) The Host dimensions shall be 19"W x 1.75"H x 9.5"D. The weight shall be 7.4 lbs. The Node dimensions shall be 9.6"W x 1.8"H x 9.6"D. The Node weight shall be 3.12 lbs. B. Front Panel The front panel of the IMS-4000 Host shall consist of eight Environmental Sensor Inputs with green and red LED status indicator lights, one internal microphone, one external microphone 1/4" jack, one Ethernet port with data transmission LEDs, one serial port, one phone jack with LED light, and one LED each to indicate Battery Power Alarm and AC Power Alarm status. The eight sensor inputs shall be configured to interface with IMS-4000 series sensors. C. Rear Panel The rear panel of the IMS-4000 Host shall provide one power switch and one IEC 320 connector with fuse. III. Electrical Specifications A. Power Source The system shall operate from 90-260VAC 50/60Hz power. Input power connection shall be IEC 320 type. Typical power consumption shall be 25 Watts. B. Battery Backup The Host shall include an internal UPS that automatically switches to battery backup in the event of an AC power failure. The battery shall be a 12V 2.9AH gel cell, which will keep the unit operating for approximately 3.5 hours when fully charged and under normal operating conditions. IV. Environmental Input Attributes and Features A. Environmental Inputs The system shall come standard with 8 environmental input channels designed to interface with IMS-4000 series sensors. The input resolution shall be 12-bit. All input values shall read to one decimal place. V. IP Monitoring Attributes and Features The system shall have the following built-in monitoring features: 1. AC power failure detection 2. Low battery detection 3. Sound monitoring via internal or external microphone 2

All monitored channels, including built-in monitoring features, shall allow local and remote data programming of pertinent operational data including, but not limited to: 1. Input name 2. Input class 2. Input calibration 3. High and Low limits 4. Input recognition time 5. Alarm reset time 6. Data logging 7. Alarm on Return-to-Normal 8. Master Enable/Disable for each channel to dial out for alarm 9. 24 hour/7 day alarm monitoring schedule VI. Communications Features A. Communication Methods The system shall be able to communicate alarms and other status information using the following methods. 1. Programmable voice 2. Fax 3. Numeric pager 4. Alphanumeric pager 5. Internet E-mail 6. Web page 7. SNMP B. Telephone Specifications The system shall connect to a standard 2-wire telephone line using tone dialing methods, with loop start only. The system shall recognize ringer frequencies from 16 to 60 Hz. No leased or dedicated lines shall be required. Call progress detection shall ensure that the alarm dialout is not hindered by no-answers or busy signals. D. Communications Interface The system shall have a built-in RS232 serial port for the purpose of network configuration and system options. The system shall have a built-in 10/100Base-T ethernet port for network communication via IMS-4000 ConsoleView software, SNMP, web page and e-mail. E. User Profiles The system shall be accessible by up to 64 users. Each user shall have configureable permissions for security purposes. Each User shall have up to 8 contact destinations in the event of an alarm. F. Contacts (Telephone Numbers, E-mail Addresses, Pager Numbers, etc.) The system shall be capable of delivering alarm messages to up to 8 contacts (36 digit telephone numbers /64 character e-mail addresses) per User Profile. There shall be a capability to schedule the availability of each contact over a 7 day/24 hour period 3

G. Voice Messages The system shall have the ability to record, store and reproduce voice messages and to use those messages to articulate the location and status of the monitored sensors and conditions. In absence of user-recorded voice messages, the system shall articulate status using the internally resident vocabulary of default messages associated with each sensor class. There shall be one recorded identification message for the system Host, and one recorded alarm message for each Node and sensor input. Message format shall be PCM, 8KHz, 8 bit, mono. H. Web Status The software shall be capable of producing a web page that includes: the status of all environmental inputs and IP alarms; logged data for each input and IP alarm; historical alarm information for each input and IP alarm; graphs of the last 24 hours of logged data; the present state of all PowerGate outlets; and live images from any associated video camera. The IMS-4000 shall be capable of automatically delivering a copy of the web page to a remote web server via FTP for viewing on another network. VI. Configuring and Programming A. Configuring Network Settings The IMS-4000 Host shall have a built-in RS232 port for the purpose of configuring the system.the port shall operate at 9600 baud, no parity, and 1 stop bit. A terminal or terminalemulation program may be used to configure the network settings. B. Programming IMS-4000 ConsoleView software shall be available via CD-ROM in order to program the Host and configure unit properties for networked Host and Nodes. VII. System Features A. Local Visual Indication Each Host sensor input shall include corresponding green and red LEDs that will indicate the present status of the input. The system shall also include two LEDs to indicate Ethernet received data (green) and transmitted data (yellow), and one LED for Phone Line Status, Battery Power Alarm, and AC Power Alarm. B. Datalog The system shall be capable of logging the values of all environmental inputs, the battery voltage, AC power status and IP Alarm history. Items to be stored shall be selectable to maximize memory usage. Up to 62,500 total samples can be stored in the unit s nonvolatile memory. The time between logs shall be user-programmable. The datalog history shall be viewable through the ConsoleView software or via the IMS web page. Data shall be available in both QuickView and HistoryView profiles. If the Datalog fills up, it will overwrite the oldest data first. It shall be possible to force a full history download of data and eventlogs. C. Security Each User Profile shall have a programmable security level for each Host and Node in the system. There shall be three levels of access: Master System Administrator, Site Administrator, and User. 4

VIII. Remote Operation Features A. Status Report & Touch-Tone Commands The system shall allow the user to call into the unit at any time using any standard telephone to obtain a full spoken status report. The report can provide information on both environmental conditions (sensors) and IP alarms. The user may also ping networked devices and switch PowerGate outlets via telephone touch-tone commands. The status report shall be articulated using the resident voice-synthesized English vocabulary, in combination with digitized userrecorded voice messages. B. User-Specific Reports The status report shall be customized based upon the user s individual User Code. A valid User Code shall be necessary to hear a status report. The unit will create a custom report based upon the Classes that the User has selected in his or her User Profile. C. Voice Acknowledgment An alarm on any monitored channel may be acknowledged remotely by pressing tones on a touchtone telephone keypad. D. Data Acknowledgment An alarm on any monitored channel may be acknowledged via the ConsoleView software or the IMS-4000 web page. E. SNMP The Host shall contain an SNMP agent that supports V1, V2c, and V3 versions of SNMP. The SNMP Agent shall be enabled or disabled via local configuration options while directly connected to the Host through the RS-232 port. Read and write access to most IMS-4000 parameters shall be provided, as well as the ability to send traps when alarms occur. IX. Environmental A. Electrical Protection Power and telephone connections shall have internal spike and surge protection using metal oxide varistors. All environmental input channels shall have fault protected input circuits. B. Additional Electrical Surge Protection Additional Power and Telephone line surge protection shall be available from the manufacturer. When so installed, the system shall be fully warranted against any damage caused by transient surges entering the system through Power or Telephone lines. C. Environmental The system shall function over an operating temperature range of 32 F 122 F at up to 5 90% RH, non-condensing. D. Maintenance The system manufacturer shall have in-house service facilities and technical assistance available during normal business hours, Monday Friday 8am 5pm(EST). Specifications subject to change without notice. 2004 Phonetics, Inc. 5

PHONETICS, INC. 901 Tryens Road Aston, PA 19014 Phone: 610-558-2700 FAX: 610-558-0222 LIT-2001 Engineering Specs 3.2004 6