G64 Area Gamma Monitor



Similar documents
AC-115 Compact Networked Single Door Controller. Installation and User Manual

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

FIREDEX Conventional Fire Panels

Digital Keypad Use s Manual

CB200W Water Leak Detection Panel Application Guide

UM-X Field display for continous level sensors

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Back-UPS Pro 1300/1500 Installation and Operation

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

Cronos -1 Gamma Object / Tool Monitors

WD-AMX Water Detection Controllers

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Electronic Control Devices The European Product Catalogue 2007

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

AlarmSense 2-wire detection and alarm system. Product Guide

SMART SENSOR COLLECTION

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

GV- RK1352 Card Reader

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

User manual Rev 1.3 Contents

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

How To Use A Ds340 (Dsp)

Rack mounted telephone- and leased line modem for industrial applications

MANUAL PC1000R

Electronic Control Devices The European Product Catalogue 2007

K9 Heat Alarm Owners Manual HA-1520

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

DC Electronic Loads 8500 series

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

TS510 & TS500. Installation & User Guide. Compatible Equipment

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MCR1900 Media Converter 19-Slot Chassis

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Conventional Fire Detection and Extinguishant Control System Specification

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Model: DC-A2IO Advanced HVAC Controller

Telephone- and leased line modem for industrial applications TD-36

PD 100A. Printing data system

Repeaters and Mimics Data Sheet

ACTIVE 5 ENGINEERING MANUAL

INTREPID Perimeter Intrusion Detection System

Installation and Operation Back-UPS 1250, 1300, 1500

Perimeter Security System

EQUIPMENT SPECIFICATIONS

EKOS Cart. Instructions for Use

Business/ Home GSM Alarm System

Modular I/O System Analog and Digital Interface Modules

SYSTEM 7000 IRIS+ USER MANUAL

HyperAccess Access Control System

Honeywell Analytics Lines of Business

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Current Monitoring Kit QUICK START GUIDE

Keep it Simple Timing

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Catalog. Arc Guard System TM TVOC-2

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members:

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

for CS flow / dew point sensors

Current Monitoring Kit

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

GSM HOME SECURITY SYSTEM

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

LT-82 Stationary IR Transmitter

HCR3.2/.. Chipcard reader HOTEL SOLUTION

L5354 ControlNet Communications Interface

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Combi B Alarm box. Mounting instructions

Business/Home GSM Alarm System. Installation and User Manual

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

User Manual. EtherUSB

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Wireless Home Security Alarm System AM 500

15 Series - Electronic step relay and dimmer. Features SERIE

Nardalert S3 Non-Ionizing Radiation Monitor

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

OZW30. Central Unit SYNERGYR

Transcription:

Features Solid state detector: range 0.1 µsv/h to 100 msv/h (10 µr/hr 10 R/hr) Pseudo-logarithmic ratemeter averaging for good statistics at low level and fast response at high levels Removable detector unit for remote use Ion chamber detector option for high range applications 100 µsv/h to 100 Sv/h (10 mr/hr 10 kr/hr) SC & GM options available for use with customer s own scintillation or GM probes Three user-set alarm levels across the full range Local signalling by audio and visual alarms Remote signalling by relays, 4 20 ma and RS-485 communications outputs Displays on high visibility LCD Status, fault and alarm messages shown clearly Membrane push buttons allow alarm mute and reset Keypad allows parameter adjustment Interlock monitor functionality Front panel RS-232 port for configuration by local PC Optional iconfig PDA configuration unit G64 Area Gamma Monitor Description The G64 Area Gamma Monitor is a compact, mains-powered, microprocessor-based radiation monitor, designed specifically for area and process monitoring in nuclear facilities. Its main functions are to display the gamma dose rate in the area and to warn local personnel in the event of an alarm situation. It can also function as an interlock monitor. The G64 is intended for installed use but can also be used on a bench stand or wheeled trolley to provide temporary monitoring or to supplement permanently installed monitors during maintenance activities. The only requirements of the basic system are a G64 monitor, suitably mounted (wall mounting brackets supplied), and a mains power supply in the range 100-240 V ac. G64 Area Gamma Monitor The standard G64 is supplied with a compact solid state detector for use in low to medium dose rate applications. The detector is directly mounted on top of the display/alarm unit. For remote monitoring applications, the detector assembly can be easily dismounted from the display/alarm unit and installed at distances of up to 100 m (328 ft) using a Remote Detector Kit. The user must simply ensure that connections between the detector and the G64 display/alarm unit are correct and that the detector is mounted using the wall mounting bracket supplied. The G64 is also available in three other versions for additional applications: 1. G64IC: for high dose rate and high integrated dose applications. Supplied with a remotely mounted ion chamber detector, 10 m (33 ft) dual coaxial detector cable and a remote amplifier/interface unit. 2. G64SC: intended for use with existing scintillation detectors and therefore not supplied with a detector. Scaled in cps kcps and supplied with a remote scintillation detector amplifier/interface unit for connection to customer s own installed detector. 3. G64GM: primarily intended for use with existing GM probes and therefore not supplied with detectors equipped with a remote GM detector amplifier/interface unit for connection to customer s own installed GM detector. Nuclear Measurement Solutions for Safety, Security and the Environment www.canberra.com C38991 09/11

Operating Principle A block diagram of the G64 with solid state detector is shown below. Gamma radiation interactions in the G64 solid state detector produce charge pulses whose magnitude and frequency are proportional to the incident energy and dose rate. These charge pulses are amplified and shaped to produce a series of voltage pulses, each of which, if it is above the minimum energy that the G64 has been designed to detect, triggers an RS-422 pulse which is sent to a scaler. The scaler contents are read out at regular intervals by a microprocessor and converted to the corresponding radiation dose rate. An adaptive software algorithm is used to ensure both a rapid response to step changes and good statistical accuracy, even at low dose rate levels. The microprocessor controls the G64 s indicators, alarm annunciators and external communications. Ion Chamber Detector The G64 Ion Chamber Detector is a small, environmentally-sealed (IP65) gamma radiation detector, which is designed to replace the standard solid state semi-conductor detector in high dose/high dose rate environments. The detector (inside the high dose rate environment) is connected to its remote amplifier/interface unit (outside the high dose rate environment) by 10 m (33 ft) of special connecting cable (supplied). The amplifier/interface supplies the high voltage required by the ion chamber and converts the low level current signal to a frequency signal for transmission to the G64 display/alarm unit via up to 50 m (164 ft) of standard twin twisted pair cable. The amplifier/interface unit also receives 12 V dc power from the G64 display/alarm unit via this cable. In low dose rate areas (<20 µsv/hr) the G64IC ion chamber may need an internal 18 kbq (0.5 µci) 241 Am holdup source installed inside in order to give a constant indication that the detector is operating (as required under International Standards for Monitors). G64 SC and GM Systems Both of these systems are supplied without detectors, as their primary purpose is to replace or upgrade old system electronics where the customer desires to retain the existing detector. Each system has a remote amplifier/interface unit designed to supply the high voltage required by the detector and amplify the detector pulses and convert them to RS-422 format for transmission to the G64 display/alarm unit. Both the SC and GM amplifier/interface units have a very wide range of gain and high voltage settings, to allow them to be set up to match a wide variety of scintillation or GM detectors. INPUTS Semiconductor Detector RADIATION DETECTION Comparator USER INTERFACE Keypad Charge Amplifier Main Voltage Amplifier & Shaping Scaler Power Supply ALARM ANNUNCIATORS COMMUNICATIONS Beacon Sounder Microprocessor RS-232/RS-485 Current Loop Relays RS-422 Pulse Digital Display Status LEDs INDICATORS OUTPUTS

Configuration The G64 incorporates a universal power supply that operates over the mains range 100-240 V ac. Therefore, no switches or links are required to operate at any voltage within this range. On power-up, the G64 will perform a self-test and when this has been successfully completed it will commence monitoring. Using a Remote Detector To remove the detector assembly, simply open the front panel of the G64, pull out the retaining pin and unplug the assembly from the top of the unit. Install and connect the detector using a G64 Remote Detector Kit, which consists of: detector mounting bracket cover plate for top of main G64 unit cable (standard lengths 10 m, 25 m or 100 m), terminated with a 9-way D-type connector that plugs directly into the remote detector. The flying lead of the cable is connected to the screw terminal block within the instrument. The cable is a twin twisted pair; two wires for DC power and two for RS-422 pulses from the detector. The same cable connection is used for the IC, SC and GM remote amplifiers/interfaces. The G64 can be configured via the front panel RS-232 port using the PC Config software supplied with the unit or the optional iconfig PDA. This software allows access to all user-settable parameters. In addition, the most commonly accessed parameters (e.g. alarm levels) can be accessed via the front panel keys using a hidden passcode key sequence. This access can be disabled for additional security if required. Parameters accessible via the keypad include: detector type, calibration factor and dead time alarm levels and responses fault condition responses alarm level detection factor high alarm delay time detector nil-count timeout period analogue output (4-20 ma) start decade and range (number of decades) averaging algorithm to be used (pseudo-log or fixed time). The status of the operating parameters may be viewed at any time by means of soft keys and the LCD display on the front panel. In the event of an alarm situation, two soft keys are available on the front panel to allow the user to mute the sounder (the beacon continues to flash) or to reset the instrument. Indicators Readings and other data are displayed on a large 16 character x 2 line liquid crystal display (LCD) provides a more precise indication of the dose rate. It is permanently backlit for easy viewing. The display indicates the current alarm level setting when the corresponding soft key is pressed. The LCD also indicates the current system parameters when the scroll data soft key is pressed. When the G64 is operating normally, the green beacon will be constantly illuminated. The G64 has three light emitting diodes (LEDs) located above the LCD display, which indicate whether it is normally operational, in a fault condition or working off its internal battery ( AC fail ). Alarms and Annunciators The G64 has three alarm thresholds, all of which are user settable. The alert and high alarms are triggered when the ambient radiation level exceeds these thresholds. Both can be set across the range of the instrument, although the alert level must always be less than the high level. The user can select which annunciators are associated with these alarms, whether they are to be latched or unlatched, and what detection factor is to be applied.

The detection factor allows the user to set thresholds at a fixed number of standard deviations above and below each alarm level to provide confidence that an alarm is genuine rather than a statistical fluctuation. For example, if an alarm level in µsv/h is equivalent to 100 cps recorded in the detector and the detection factor is set to 2 sigma, then the alarm will be generated when the count rate exceeds 120 cps and will be maintained until it falls below 80 cps. The low alarm threshold differs from the other two in that, in this case, the alarm is triggered if the radiation falls below this level. Its main purpose is to identify a detector failure and it therefore shares the same relay as the equipment fault. Alarm annunciation is by means of: the red beacon, which flashes the sounder, which can be configured by the user to one of 24 different tones and frequencies (e.g. to avoid confusion with other plant devices) via switches accessible behind the front door. LEDs, located below the LCD, indicate which of the three alarm conditions has been registered. The user may suppress alarm annunciation for either or both of the activity alarms if required. In the event of a sustained mains failure, full operation is supported by an internal battery for at least 30 minutes. Outputs and Communications Connections to the G64 are via unplugable screw terminal blocks, accessible, with the front panel open, through compression glands on the underside of the instrument. The G64 enables the user to control external devices and to transmit data to local or remote locations via: three sets of volt-free changeover contacts for the alert and high activity alarms and the low activity alarm/equipment fault condition. Relays can be configured to operate in the fail-safe mode, i.e. normally energized (default setting) or in normally de-energized mode RS-232 serial port for communication to local PC or PDA RS-485 serial port for communication with remote monitoring systems current loop output for driving a chart recorder RS-422 pulse output for connection to distributed control systems. Diagnostics The G64 incorporates a number of hardware and software diagnostics to identify the nature of any fault in the operation of the instrument. Faults that will be detected are: 5 V, 12 V or 24 V dc line fault (check) low internal battery voltage detector fault mains failure microprocessor fault Occurrence of any of these conditions will cause the green beacon to flash and will trip the equipment fault relay. The nature of the fault will be displayed on the LCD. The G64 includes a back-up battery to provide up to 5 seconds immunity to temporary mains interruptions and up to 30 minutes of full operation (with AC fail indication) if the interruption is sustained. During this period it will emit a constant audio tone and flashing green beacon and the AC fail LED will be illuminated. G64 Interlock Monitor The three sets of volts-free changeover contacts provided in the monitor can be configured for interlock control. In these applications the beacons may be removed if not required, and the sounder disabled.

Related Equipment D1 Slave Alarm The D1 Slave Alarm is designed for use with any monitoring instrument, including the G64 Area Gamma Monitor, whose output provides a pair of volts-free relay contacts. In its standard configuration the Slave Alarm is actuated when the relay contacts open, signalling the alarm condition with an audio sounder and a flashing red beacon. The D1 is mains powered and can be set for use with a 110 V or 240 V ac power supply. Accessories remote Detector Kit (10 m, 25 m, 100 m) (33 ft, 82 ft, 328 ft) includes pre-terminated cable, blanking plate and wall mount for detector bench stand with RCD and MCB 110 V ac or 240 V ac versions (/B110 or /B240 option) trolley mount with RCD and MCB 110 V ac or 240 V ac versions (/T110 or /T240 option) test pulse generator RADACS G64 is compatible with CANBERRA s RADACS environmental surveillance and monitoring software. RADACS allows the implementation of large networks of varied monitoring instruments to provide total surveillance and control of radiological conditions throughout plants and facilities. PART G64CAL G64ICCAL G64DA G64RD/A G64RD/B G64RD/C G64TB G64SA iconfig ICAM/B240 ICAM/B110 ICAM/T ICAM/T240 ICAM/T110 G64 ACCESSORIES and OPTIONS DESCRIPTION CALIBRATION OF STD G64 CALIBRATION OF G64 IC SYSTEM G64 DETECTOR ASSEMBLY (spare) G64 AREA/INTERLOCK GAMMA MONITOR REMOTE DET KIT (10 m) (33 ft) G64 AREA/INTERLOCK GAMMA MONITOR REMOTE DET KIT (25 m) (82 ft) G64 AREA/INTERLOCK GAMMA MONITOR REMOTE DET KIT (100 m) (328 ft) G64 TEST BOX (PULSE GENERATOR) D1 SLAVE ALARM UNIT ICONFIG POCKET configuration unit for icam and G64 BENCH STAND C/W CABLES and MAINS ISOLATORS BENCH STAND C/W CABLES and MAINS ISOLATORS TROLLEY KIT bare/unwired trolley for wheeled transport of bench stand mounted systems TROLLEY C/W CABLES and MAINS ISOLATORS TROLLEY C/W CABLES and MAINS ISOLATORS

Specifications PHYSICAL RADIOLOGICAL STANDARD IEC532, installed dose rate meters, warning assemblies and monitors for X- and gamma radiations of energy between 50 kev and 7 MeV (1992). RESPONSE TIME <6 seconds to 90% of final step change value. DYNAMIC RANGE 0.1 µsv/h to 100 msv/h (10 µr/hr 10 R/hr). G64 SOLID STATE DETECTOR LINEARITY ±10% from 1 µsv/h to 100 msv/h ( 137 Cs radiation). ENERGY RESPONSE 70 kev to 7 MeV ±30% normalized to 137 Cs. POLAR RESPONSE ±20% over 4p for 137 Cs. ENVIRONMENTAL Operating temperature 0 C to +40 C (32 F to 104 F). Relative humidity to 85% (non-condensing). ENVIRONMENTAL PROTECTION IP65 when mounted on G64. POWER REQUIREMENTS 12 V dc, typically 30 ma (supplied by G64 Display/Alarm unit). DIMENSIONS 85 x 75 x 60 mm (3.3 x 2.9 x 2.4 in.). WEIGHT 0.5 kg (1.1 lb). G64IC ION CHAMBER SYSTEM MEASUREMENT RANGE 100 µsv/h to 100 Sv/h (10 mr/hr 10 kr/hr). TEMPERATURE RANGE 0 C to 40 C (32 F to 104 F). ENVIRONMENTAL PROTECTION IP65. POWER REQUIREMENTS 12 V dc, typically 100 ma (supplied by G64 Display/Alarm unit). DIMENSIONS Detector: Approximately 230 mm (9 in.) long x 50 mm (2 in.) Diameter. Amplifier/Interface: 210 x 80 x 63.5 mm (8.3 x 3.1 x 2.5 in.). G64SC SCINTILLATION SYSTEM MEASUREMENT RANGE Range 0.1 cps 100 kcps. AMPLIFIER INTERFACE UNIT/POWER SUPPLY +12 V dc, 210 ma (supplied by G64 Display/Alarm unit). TEMPERATURE RANGE 0 C to +40 C (32 F to 104 F). HUMIDITY 0%-85%, non condensing. DIMENSIONS 65 x 210 x 80 mm (2.6 x 8.3 x 3.1 in.) (H x L x W) (including mounting plate). WEIGHT Remote interface box <3 kg (6.6 lb). HIGH VOLTAGE +500 V to +1800 V into >20 MW load impedance. DISCRIMINATOR THRESHOLDS 0.1 V, 0.5 V or 2.5 V. TRANSFER FACTOR 8 mv/pc or 160 mv/pc. INPUT IMPEDANCE 50W. PULSE SHAPING 1 µs. G64GM SYSTEM MEASUREMENT RANGE RANGE dependent on GM probe used: typically 0.1 µsv/h to 7.5 msv/h (10 µr/hr 0.75 R/hr) with MC10P probe. 100 µsv/h 10 Sv/hr (10 mr/hr 1 kr/hr) with MC10PS probe. AMPLIFIER INTERFACE UNIT/POWER SUPPLY 12 V dc 170 ma. TEMPERATURE RANGE 0 C to +40 C (32 F to 104 F). HUMIDITY 0%-85%, non condensing. DIMENSIONS 65 x 210 x 80 mm (2.6 x 8.3 x 3.1 in.) (H x L x W) (including mounting plate). WEIGHT Remote interface box <3 kg (6.6 lb). DISPLAY/ALARM UNIT DISPLAY LCD digital output 6 decade Meter D analogue indication. OUTPUTS Three Fail-safe relays for faults and alarms, each with two sets of changeover contacts. RS-232/RS-485 interfaces RS-422 format pulse output. Current loop (4-20 ma). ENVIRONMENTAL PROTECTION IP54 (limited by beacon). POWER SUPPLY 100-240 V ac 35 VA Internal backup battery (rechargeable) giving >30 minutes backup. DIMENSIONS 445 (including beacon and connectors) x 175 x 100 mm (17.5 x 6.9 x 3.9 in.). WEIGHT 3.5 kg (7.7 lb). PRODUCT CODES G64 G64 Area monitor with solid state detector (SI units). G64R G64 Area monitor (US units) with solid state detector. G64IC/A G64IC High dose rate area monitor version with 10 m (33 ft) screened twisted pair cable from amplifier to G64 controller. G64IC/B G64IC System with 25 m cable supplied with 25 m (82 ft) screened and twisted pair cable from amplifier to G64 controller. G64IC/C G64IC System with 50 m (164 ft) cable. G64SC/A Cooling water monitor (excludes detector) version with 10 m (33 ft) screened twisted pair cable from amplifier to G64 controller. G64SC/B Cooling water detector version with 25 m (82 ft) screened twisted pair cable from amplifier to G64 controller. G64SC/C Cooling water monitor (excludes detector). G64GM/A G64 Geiger Mueller System (excluding detector) supplied with 10 m (33 ft) screened twisted pair cable from amplifier to G64 controller. G64GM/B G64 Geiger Mueller System (excluding detector) version with 25 m (82 ft) screened twisted pair cable from amplifier to G64 controller. G64GM/C G64 Geiger Mueller System (excluding detector) version with 100 m (328 ft) screened twisted pair cable from amplifier to G64 controller. RADACS is a trademark of Canberra Industries, Inc. 2011 Canberra Industries, Inc. All rights reserved.