Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES



Similar documents
Multiresidue Analysis of Pesticides in Avocado with Agilent Bond Elut EMR Lipid by GC/MS/MS

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Multiresidue Analysis of Pesticides in Avocado with Agilent Bond Elut EMR Lipid by LC/MS/MS

How To Test For Contamination In Large Volume Water

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Multi Pesticides Residue analysis in Ayurvedic cough Syrup by GCMS/MS using QuEChERS extraction method

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

LC-MS/MS for Chromatographers

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

[ DISQUE DISPERSIVE SAMPLE PREPARATION EXTRACTION PRODUCTS ] QuEChERS. Simplifed

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

AppNote 1/2008. Automated Disposable Pipette Extraction of Pesticides from Fruits and Vegetables KEYWORDS ABSTRACT

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

The Chemistry of QuEChERS. Quick, Easy, Cheap, Effective, Rugged and Safe Method for Determining Pesticide Residues

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Oasis HLB Cartridges and 96-Well Plates

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Pesticide Analysis by Mass Spectrometry

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

LC-MS/MS, the new reference method for mycotoxin analysis

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Sample Preparation for Forensic Toxicology and Clinical Research. Part 1: Sample Preparation Options

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

A Novel Approach to Low Volume Sample Preparation

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Tracer Detection Systems

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

Guidance for Industry

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

How To Analyze Pesticide Levels In Lemon Oil

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

WATERS QUANTITATIVE ANALYSIS solutions

Signal, Noise, and Detection Limits in Mass Spectrometry

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Analytical Test Method Validation Report Template

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

Agilent LCMS products and the application strategies in veterinary drug analysis

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

Innovative vs Traditional

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

S olid Ph ase Extraction (SP E) Method:

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS

MassHunter for Agilent GC/MS & GC/MS/MS

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Transcription:

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

AGILENT ENHANCED MATRIX REMOVAL LIPID ARE LIPIDS WEIGHING YOUR SAMPLES DOWN? Interference from lipids is a problem for labs measuring trace residues in fatty foods or complex biological matrices. Lipids can build up in the instrument and column, decreasing lifetime and reducing analyte sensitivity due to ion suppression. The need for MS maintenance increases too, because of lipid deposits on the source. The need for lipid removal is well understood, but current methods often sacrifice analyte recovery, removing some of your target analytes along with the lipids. Now, you don t have to choose between lipid removal and analyte recovery, because innovative Agilent Enhanced Matrix Removal Lipid delivers the most complete matrix removal and analyte recovery of any sample prep product. Enhanced Matrix Removal Lipid, UNLIKE any other type of sample prep, is a unique sorbent that selectively removes lipids in complex matrices and challenging high-fat samples such as avocado, so you can remove lipids without losing your analytes. x 6..4.3...9.8.7.6..4.3.. Avocado Quechers extract before dspe Avocado Quechers extract with C8/PSA cleanup Avocado Quechers with EMR Lipid cleanup 9% Matrix Removal with EMR Lipid 6 7 8 9 3 4 6 7 8 9 3 4 6 7 8 9 3 3 3 33 34 3 vs. acquisition time (min) Figure. GC/MS full-scan chromatogram overlay of an untreated QuEChERS avocado extract (black), compared to traditional C8/PSA cleanup (red) and an extract treated with Agilent Enhanced Matrix Removal Lipid (blue).

STANDARD QuEChERS Extraction/partition (6 steps) Mix and centrifuge Transfer to dspe (sorbents) Mix and centrifuge Evaporate/reconstitute or dilute Filter out precipitate Transfer to A/S vial EMR LIPID QuEChERS Extraction/partition (6 steps) Mix and centrifuge Transfer to dspe (EMR Lipid & HO) Mix and centrifuge Polish* Evaporate/reconstitute or dilute Transfer to A/S vial The innovative sorbent in EMR Lipid replaces C8/PSA in your QuEChERS methodology to significantly reduce matrix effects and improve analyte recoveries. It can be universally applied to the analysis of polar, mid-polar and non-polar target analytes, providing effective matrix removal. *Note: Polish step is omitted for tetracycline analysis. Sample Type Removal (%) Avocado 9 Olive oil 73 Avocado oil 8 Canola oil 7 Beef liver 97 Wet cat food 9 Paprika 9 Cumin 7 Hops 7 Tumeric 47 Black pepper Onion 4 Strawberry Plum Red pepper 6 Spinach 6 Orange Apple 66 3

EMR LIPID MINIMIZE LIPIDS. MAXIMIZE RESULTS. Analyte recovery % (n=6) in ppb pesticides fortified avocado 8 6 4 Methamidophos EMR Lipid cleanup C8/PSA dspe cleanup Zirconia sorbent cleanup Thiophanate methtyl Bentazone,4-D Acid Dichlorprop Penconazole TPP EPN Captafol EMR Lipid significantly removes matrix contributions, improving recovery across many analytes and minimizing your need for separate workup and methods. Figure 3. Recovery data for multiple pesticide residue analysis in avocado, showing some of the 73 pesticides analyzed. Using Agilent Enhanced Matrix Removal Lipid, 9% of the pesticides fell within the acceptable recovery range of 7 to %. Analytes Recovery % (n=6) in ppb vet drugs fortified in bovine liver samples 3 REC<7% REC in 7 % REC> Higher efficiency matrix removal with EMR Lipid results in higher precision and greater accuracy in results. Figure 4. Number of analytes with % recoveries within the acceptable % recovery range of 7-% for the analysis of vet drugs in Bovine Liver, demonstrating the higher number of acceptable results after Agilent Enhanced Matrix Removal Lipid Cleanup vs zirconia sorbent. EMR Lipid cleanup C8/PSA cleanup Zirconia sorbent cleanup 4

Chromatographic benefits of sample preparation using EMR Lipid QuEChERS Efficiently removing lipids from samples without removing analytes is the key to improving chromatographic performance for the best quality data, especially with high-sensitivity MS detectors. An EMR Lipid QuEChERS protocol considerably improves accuracy, reproducibility, and low-level quantitation when using GC/MS and LC/MS (Figure ). BENEFIT BETTER ANALYTE SENSITIVITY IMPROVED S/N RATIO LESS INTERFERENCES FOR ACCURATE INTEGRATION Example EPN in avocado on LC-QQQ Captan in avocado on GC-QQQ Permethrin in avocado on GC-QQQ EMR Lipid cleanup Zirconia sorbent cleanup C8/PSA cleanup 3. 3.8.6.4..8.4..8 3..63.4.8.6..4..8.4..8.6.4. x 3.. x 3.. x 3.. +MRM (34. -> 96.) AVBVR POQ4.d 4.863 min. 4. 4.46.4 Acqusition Time (min) +MRM (34. -> 96.) AVZ-Sep+ POQ 4.d 4.863 min. 4. 4.46.4 +MRM (34. -> 96.) AVC8 PR-Q3.d 4.8 min. 4. 4.46.4 x 4.6 +MRM (. -> 79.)AV MBPI-a-CD C spike ppb-.d 3.63 min..8.. -..7 3 3. 3.4 3.6 x...8.. -. x.4...8.. -. +MRM (. -> 79.) AV Z-Sep+ C spike ppb-.d.7.9 3. 3.4 3.6 +MRM (83. -> 68.)AV x 4 MBPI-a-CD C spike ppb-.d.788 min. 4. 3....7 -..4.6.8. Figure. Improvements in chromatography can be seen in the analysis of samples prepared with Agilent Enhanced Matrix Removal Lipid, including better sensitivity due to reduced matrix ion suppression, better signal-to-noise ratio, and fewer interferences providing accurate integration with GC or LC triple quadrupole systems. 3.63 min. +MRM (. -> 79.) Post-S ppb Fatty cspe C-.D *3.74 min..7.9 3. 3.4 3.6 +MRM (83. -> 68.) AV MZ-Sep+ C spike ppb-.d.89 min. x 4 7 6 4.4.6.8. +MRM (83. -> 68.) AV Fatty dspe spike ppb-r.d.833 min. x 4 7 6 4.4.6.8.

FASTER SAMPLE PREP STREAMLINES LAB PRODUCTIVITY Without effective sample cleanup, analytical efficiency and quality are quickly compromised as fatty matrices build up in the instrument and column. With EMR Lipid, system performance is maintained even after injections of a fatty-matrix sample like avocado. Reduced maintenance allows for increased sample throughput and enables you to use your assets to their fullest extent, maximizing productivity in your lab. 8 6 4 TPP peak area 8 6 4 Figure 6. Analyte response across avocado sample injections. Triphenyl phosphate (TPP) is a commonly used internal standard. Signal suppression or enhancement can result from insufficient cleanup of samples, which can contribute to poor data quality, errors, and re-running samples. The superior EMR Lipid cleanup. Response drops 4% Zirconia sorbent cleanup. Response drops % C8/PSA cleanup. Response increases 3% matrix removal ability of Agilent Enhanced Matrix Removal Lipid, results in a cleaner source and more consistent MS response over time, for higher quality data, fewer re-runs, and reduced need for time-consuming troubleshooting and source maintenance. 3 3 4 4 6 6 7 7 8 8 9 9 Injections of avocado extract samples on GC/QQQ Relative abundance for tuning ion (%) 3 9 8 7 6 4 3 PARAMETER EM voltage Rel. abundance MS ion 9 Rel. abundance MS ion METHOD PERFORMANCE CRITERIA >6V needs EM replacement Min 7 Min 6 4 8 6 4 EM Voltage With EMR Lipid there is less need for system maintenance and calibration due to fewer sample matrix interferences. As a result, fewer samples need to be re-run. This advantage lets you operate at higher throughput, resulting in cost savings and a more efficient lab. Figure 7. GC/MS source conditions during injections of avocado samples, demonstrating significantly reduced frequency of MS source maintenance (cleaning or replacement) when using Agilent Enhanced Matrix Removal Lipid. Injections of avocado samples after QuEChERS EMR Lipid cleanup 6

Analytes RSD over injections on GC/QQQ (n = ) Pesticides EMR Lipid Cleanup C8/PSA Cleanup Zirconia sorbent Cleanup Dichlorvos 6.. 6.8 -Phenylphenol 7. 3.6 9. Ethalfluralin.4 8.8 3. Sulfotep 7..8 7. Atrazine 6.8. 9. Lindane 8..8. Chlorothalonil..7 37.4 Diazinon 6.6.7 6.9 Chlorpyriphosmethyl 8.4 8.9 4.9 Dichlofluanid.7 9..9 Aldrin 9.8 9.3.7 Tolylfluanid. 6.6 7.8 Captan 9.9.9 47. Procymidone 6.8 4.3. Bupirimate 6.8.4.7 Endrin 8.3.6 4. Endosulfan sulfate 8...4 DDT.4 4.6 Iprodione..7 4. Permethrin 6.8.8 8.8 Parathion ethyl.8 7. 3. TPP 9. 9.9 8.3 Over a hundred runs of fatty sample analysis, the consistently better, effective clean up of EMR Lipid results in lower % RSDs and greater confidence in results, compared to alternative QuEChERS procedures. Higher quality data with better precision results in less need for data re-verification, justification and fewer costly re-runs. Figure 8. Reproducibility of pesticides analyzed (%RSD) over multiple injections of avocado samples on GC/QQQ. ppb fortified avocado samples were tested every five injections, and avocado matrix blanks were injected in between. RSD > % are considered as unacceptable and marked in red. The benefits of using new and innovative EMR Lipid for QuEChERS are clear Improved productivity: better sensitivity and signal-to-noise from fewer matrix interferences enable faster data processing, and greater sample throughput. Reduced lab costs: cleaner samples using EMR Lipid can offer significantly reduced MS source maintenance, giving you more time to analyze samples rather than spend time on costly troubleshooting, downtime, and instrument repair. Simplified workflows: standardize on an easy-to-use single-sorbent procedure that maximizes analyte recovery from a wide variety of fatty samples. Save time and money by reducing material costs, inventory, training time, and documentation, thereby streamlining your lab productivity. Higher quality results: a cleaner sample profile leads to greater data integrity and confidence in results, faster data processing, and fewer re-runs. Part Number Description 98- Bond Elut QuEChERS EMR Lipid dspe 98- Bond Elut QuEChERS EMR Lipid Final polish 7

The best analysis requires the best overall workflow Explore more food testing solutions at www.agilent.com/chem/food Increase analysis throughput with current instruments and minimal investment check how to increase your laboratory productivity here: Liquid chromatography analysis workflow agilent.com/chem/productivitylc Gas chromatography analysis workflow agilent.com/chem/productivitygc Learn more agilent.com/chem/emr-lipid Find a local Agilent customer center www.agilent.com/chem/contactus USA and Canada -8-7-977 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com India lsca-india_marketing@agilent.com For Research Use Only. Not for use in diagnostic procedures. This information is subject to change without notice. Agilent Technologies, Inc., Published in the USA, July 7, 99-6EN