Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M



Similar documents
Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Opiates in Urine by SAMHSA GC/MS

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Analyzing Small Molecules by EI and GC-MS. July 2014

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Analysis of Phthalate Esters in Children's Toys Using GC-MS

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

How To Test For Contamination In Large Volume Water

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Determination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

Griffin 460 Mobile GC/MS Analysis of Designer Drugs, Including Synthetic Cannabis & Bath Salts, Utilizing Prepless Sample Introduction (PSI) Probe

How To Use An Acquity Qda Detector

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

SCREENING FOR THE PRESENCE OF PARA-METHYLTHIOAMPHETAMINE IN URINE BY SOME COMMERCIAL IMMUNOASSAYS AND CONFIRMATION BY GC/MS

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

MASS SPECTROMETRIC IDENTIFICATION OF SOME SULPHUR CONTAINING PHENALKYLAMINE DESIGNER DRUGS *

Expectations for GC-MS Lab

Chemical analysis service, Turner s Green Technology Group

AMD Analysis & Technology AG

aurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Bridging the analytical gap

Micromass LCT User s Guide

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

SCION SQ Series GC-MS

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Analysis of Liquid Samples on the Agilent GC-MS

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

lung cancer targeted photodynamic therapy and imaging

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Analytical Test Report

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Purification of reaction mixtures using flash chromatography.

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

GC/MS BATCH NUMBER: CK0102

Benzo[a]pyrene Method Development

Appendix 5 Overview of requirements in English

Determination of polyols derived from sugars and residual sugars found in dry wines by means of gas chromatography (Resolution Oeno 9/2006)

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

Background Information

Pesticide Analysis by Mass Spectrometry

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Quantitation of Drugs in Dried Bloodstains. Thomas Meyer Anna Gomenyuk Nadiah Lester

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Samples RMN Analytical Report ( ) GC/FID Analysis (RM01) Nicotine Purity

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary

QGA Quantitative Gas Analyser

GC/MS Considerations for Fracking Gases and Water. Dr. Harold McNair Virginia Tech Blacksburg, VA.

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

SUCRALOSE. White to off-white, practically odourless crystalline powder

How To Develop A Recipe Card

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

A Complete Solution for Method Linearity in HPLC and UHPLC

Identification of Arson Accelerants by Gas Chromatography

Q-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: Gaschromategraph GC 5000 BTX Type FID for Benzene

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 &

Setting up a Quantitative Analysis MS ChemStation

Storage Conditions of Sausages

How To Use Gc-Ms

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Available online at Procedia Engineering 00 (2010)

Transcription:

Bruker Daltonics Application Note # MS- Fast n-site Identification of Drugs with the mobile GC/MS system E²M For the detection of drugs a couple of quick tests are available which were used by the police departments and the State ffices of Criminal Investigations. These tests are limited to substance specific reactions and do not give any information about different drug compositions (thin down compounds, by-products, precursors, impurities etc.) which were necessary for criminal investigations. For a clear identification of complex mixtures GC/MS is still the method of choice. With the mobile GC/MS system E²M a fast and inexpensive detection and identification of drugs can be accomplished directly at the scene of crime. This application note demonstrates the time saving determination of different drugs/drug compositions with the E²M in the GC mode and by direct measurements with the Air/Surface probe. Sampling preparation For this application note the following solutions were prepared by dissolving the raw material in methanol (hashish:.7 mg/ml, marihuana:. mg/ml, morphine:.8 mg/ml, cocaine:. mg/ml, heroin:.6 mg/ml). For the identification on-site (not quantification) where a microbalance may not be present this can be done by transferring the amount of one micro-spatula tip ( 5 mg) into a vial filled with ml methanol. Figure : pium poppy yields the raw material for morphine and heroin production..

Chromatogram and appropriate mass spectra from a morphine sample x 6 x 5.5..5..5. 5. +M S, Disse ct, 8.6-5 8. s # ( 7 7-8 6 ). 5 9. 8. 9.. 6 8 Time [s] 6. 6.. 5 6.. Nist: Ethylmorphine; Q EI +MS (P : 79, F: 86, R : 89, M : ) 8.. Analytical conditions E²M with mounted GC in injector mode:.5 m HP5-ms,. mm ID, µm film. injector temperature:, hold-time: s, charging time: s, pressure during charging: 6 mbar, GC temperature program: to at 5 /min (hold: 6s), carrier gas: ambient air at.5 ml/min, MS Scan: 6 5 u, integration time: 5 ms/mass; injected volume: µl. E²M with mounted Air/Surface probe: probe head temperature:, probe line temperature:, sampling pump pressure; 85 mbar. MS Scan: 6 5 u, integration time: 5ms/mass; sampling: µl with probe (pressing probe head on the sample). 7 5 H 5 5 x 5.5. 9.. 5 9. 8. 9.. 6. 6. 7 5... 8.. 8 5. +M S, Disse ct, 7 8. -5. s # ( 7 5-8 8 ) N.5..5. 5 6. 5. 7.. 6 8. 9... N ist: M o rp h in e ; Q E I + M S (P : 7 9, F: 8 8, R : 9 6, M : ) H 8 5. 7 5 5 5. N 6. 5. 5 9.. 7.. 7. H 9. 5 5 5 5 m /z Figure : GC run; Injection: µl morphine solution (.8 mg/ml): Beside morphine the derivate ethyl morphine was identified. Identified substances morphine sample 9. 7595 Ethylmorphine Nist 76-58- 79 9.5 77 Morphine Nist 57-7- 79

Chromatogram and appropriate mass spectra from a cocaine sample In te ns. x 6 6. + MS, 8 6.6 -.s # ( - ) 8. 5 5. 8. 5.. 5 5. 7.. 8. 8... 9 8.. 68. 7. 5. 6 8 Time [s]. + MS, 8 6.6 -. s # ( - ) 8. 8. 5. 5.. 5 5. 7.. 8.. 6 8.. 5. 8. 9 8. 7.. Figure : Direct sampling of µl cocaine solution (. mg/ml) from a surface with E²M Air/Surface probe; Analytical conditions: see E²M with mounted Air/Surface probe. Identified substances cocaine sample 9.8 67 Cocaine Nist 5-6- 87 Chromatogram and appropriate mass spectra from a hashish sample x 5.5. + M S, Disse ct, 8 9. -5 8.8s # ( 79-9 ). 9 9... In t en s. x 6 7.. 5.5... 5 5 5. 6 9. 9.. 7. 9. Nist: 6H-Dibenzo,D]pyran,a-tetrahydro. [b - -ol, 6a,7,8-6,6,9 -trimethyl- -pentyl -; Q EI +MS (P : 87, F: 9, R: 9, M : ). 5. 7 5.. H. 5 5 7.. 5 6 7 8 9 T im e [s] 5. 5 5. 6 9.8.9. 7. 7. 9.. x 5. + M S, Disse ct, 9 9.9-5 6.9s # ( 8-9 ) 9 5. 6 5 7 5 5 5. 8. Ni st: Ca. n n a b i n o l ; Q E I +M S (P : 9 9, F: 9 5, R: 9 8, M : ) 9 5. H 8... 6 5.. 5. 5 5 5 5 m /z Figure : GC run; Injection: µl hashish solution (.7 mg/ml): two typical components of hashish / marihuana identified: Cannabinol, THC; Analytical conditions: see E²M with mounted GC in injector mode.

Identified substances hashish sample 95.5 6659 Tetrahydrocannabinol (THC) Nist 86-5-8 87 55.8 586788 Cannabinol Nist 5-5-7 99 Chromatogram and appropriate mass spectra from a heroin sample Inte n s. x 6 8 6 Figure 5: Asian heroin. 6 8 T im e [s] TIC + Dissect:, Cm pd, 8. s Dissect:, Cm pd, 5.5 s Dissect:, Cm pd, 56.5 s x 5.8. +M S, Dissect, 5. -55.6s # (87-).6 7. 6 9.... 5 5 9. 8. 9.. 6.. 6 8.. N i st: Di a ce tylm o rp h i n e ; Q E I + M S (P : 8 8, F: 9 5, R : 9, M : ). 7. 7 5 5 5 5. 6 9.. 6 8... N 8. 9.. 6. 5 5 5 5 m /z Figure 6: GC run; Injection: µl heroin solution (.6 mg/ml): Beside diacetylmorphine (heroin) the compounds acetylcodein and novocaine were identified which are typical thin down compounds of heroin; Analytical conditions: see E²M with mounted GC in injector mode. Identified substances heroin sample 8. 557877 Novocaine Nist 59-6- 9 5.5 99596 Acetylcodein Nist 76 56.5 8999 Diacetylmorphine (Heroin) Nist 56-7- 88

Chromatogram and appropriate mass spectra from an unknown sample x 6 Figure 7: Unknown sample confiscated by the police and suspected of being a drug. 5 6 7 8 T im e [s] In te ns. x 5. +M S, Dissect, 86.-.5s #(-9 ) 5. 8. 5 9. 6. 8.. N ist: A sp i ri n ; Q E I + M S (P : 9 5, F : 96, R: 96, M : ) H. 7 5 5. 9. 8. 5 6. 8. 5 5 5 5 m /z Figure 8: GC run; Injection: µl unknown solution (. mg/ml): Results show that no drug is present; sample is just rotten Aspirin (Aspirin + salicylic acid) with some caffeine; Analytical conditions: see E²M with mounted GC in injector mode. Identified substances unknown sample 55.6 7576 Salicylic Acid Nist 69-7-7 956 95.5 Aspirin Nist 5-78- 95 5.8 78 Caffeine Nist 58-8- 7

Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. Bruker Daltonics 9-8, MS- Conclusions With the mobile GC/MS system E²M drugs (here: hashish, marihuana, morphine, cocaine, heroin) can be identified directly on the scene of crime within 5 min. The operation of the system is reduced to the lowest possible level so that non-chemists are able to run the system. In comparison to classical investigations (laboratory measurements), which are time consuming, and expensive identification of drugs can be carried out quickly and at low cost. Therefore the GC/MS system E²M is a powerful analytical tool to save time and money. Author Dr. Thomas Ludwig, Application CBRNE, Bruker Daltonik GmbH, Application-CBRNE@bdal.de Keywords: nsite Analysis Mobile GC/MS Fast drug detection Instrumentation & Software Mobile GC/MS System E²M E²M Software Package For research use only. Not for use in diagnostic procedures. Figure 9: Mobile GC/MS system E²M www.brukerdetection.com Bruker Daltonik GmbH Bremen Germany Phone +9 () 5- Fax +9 () 5- detection@bruker.com Bruker Daltonics Inc. Billerica, MA USA Phone + (978) 66-66 Fax + (978) 667-599 detection@bruker.com