IMPROVED CCD DETECTORS FOR HIGH SPEED, CHARGE EXCHANGE SPECTROSCOPY STUDIES ON THE DIII D TOKAMAK



Similar documents
16th International Toki Conference on Advanced Imaging and Plasma Diagnostics

Fig.1. The DAWN spacecraft

Diagnostics. Electric probes. Instituto de Plasmas e Fusão Nuclear Instituto Superior Técnico Lisbon, Portugal

First Measurements with U-probe on the COMPASS Tokamak

Non-Inductive Startup and Flux Compression in the Pegasus Toroidal Experiment

Introduction to reflective aberration corrected holographic diffraction gratings

Diagnostics. Electric probes. Instituto de Plasmas e Fusão Nuclear Instituto Superior Técnico Lisbon, Portugal

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Simplicity. Reliability. Performance

Experiment #5: Qualitative Absorption Spectroscopy

How an electronic shutter works in a CMOS camera. First, let s review how shutters work in film cameras.

Measurement of Resistive Wall Mode Stability in Rotating High Beta Plasmas

New Developments and Functional Enhancements in RDE Used Oil Analysis Spectrometers

Synthetic Sensing: Proximity / Distance Sensors


Advances in scmos Camera Technology Benefit Bio Research

Introduction to CCDs and CCD Data Calibration

Nederland België / Belgique

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

The accurate calibration of all detectors is crucial for the subsequent data

INFRARED MONITORING OF 110 GHz GYROTRON WINDOWS AT DIII D

Local Electron Thermal Transport in the MST Reversed-Field Pinch

Multiple Delay Coherence Imaging Charge Exchange Recombination Spectroscopy

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

View of ΣIGMA TM (Ref. 1)

S2000 Spectrometer Data Sheet

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Major Conclusions of the MFE Study

Grazing incidence wavefront sensing and verification of X-ray optics performance

Cathode Ray Tube. Introduction. Functional principle

High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules

Neutral Beam Injection Experiments in the MST Reversed Field Pinch

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

Information about the T9 beam line and experimental facilities

MRC High Resolution. MR-compatible digital HD video camera. User manual

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

Spectral Measurement Solutions for Industry and Research

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

GA A25827 EFFECTS OF ELECTRON CYCLOTRON CURRENT DRIVE, COUNTER-NBI, AND ROTATIONAL ENTRAINMENT ON NEOCLASSICAL TEARING MODE CONTROL IN DIII-D

5. The Nature of Light. Does Light Travel Infinitely Fast? EMR Travels At Finite Speed. EMR: Electric & Magnetic Waves

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

MCAL Spectrophotometry. Spectrophotometry

8.1 Radio Emission from Solar System objects

PoS(PhotoDet 2012)068

TOF FUNDAMENTALS TUTORIAL

(Amplifying) Photo Detectors: Avalanche Photodiodes Silicon Photomultiplier

Silicon Drift Detector Product Brochure Update 2013

How To Make A Plasma Control System

AUTOMATION OF OPERATIONS ON THE VEPP-4 CONTROL SYSTEM

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

ULTRAFAST LASERS: Free electron lasers thrive from synergy with ultrafast laser systems

Measuring the Doppler Shift of a Kepler Star with a Planet

Fusion Engineering and Design

State Newton's second law of motion for a particle, defining carefully each term used.

Digital vs. Analogue Control Systems

COOKBOOK. for. Aristarchos Transient Spectrometer (ATS)

Blackbody Radiation References INTRODUCTION

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

Applications: X-ray Microtomography, Streak Tube and CRT Readout, Industrial & Medical Imaging X-RAY GROUP

Silicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

Short overview of TEUFEL-project

AS COMPETITION PAPER 2008

Facilities Perspectives

Heating diagnostics with MHD waves

Presentation of problem T1 (9 points): The Maribo Meteorite

A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA

Understanding Line Scan Camera Applications

Laser drilling up to15,000 holes/sec in silicon wafer for PV solar cells

Integration of a passive micro-mechanical infrared sensor package with a commercial smartphone camera system

Lab 9: The Acousto-Optic Effect

Gamma Ray Detection at RIA

(I) s(t) = s 0 v 0 (t t 0 ) a (t t 0) 2 (II). t 2 = t v 0. At the time. E kin = 1 2 m v2 = 1 2 m (a (t t 0) v 0 ) 2

Module 13 : Measurements on Fiber Optic Systems

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

FTIR Instrumentation

hsfc pro 12 bit ultra speed intensified imaging

High Power Neutral Beam Injection in LHD

Design Strategies for High Availability: Accommodating In-Vessel Piping Services and Auxiliary Systems

C.-K. Ng. Stanford Linear Accelerator Center. and. T. Weiland. University oftechnology. FB18, Schlossgartenstr. 8. D64289, Darmstadt, Germany.

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

Robot Perception Continued

Single Photon Counting Module COUNT -Series

RECOMMENDATION ITU-R F (Question ITU-R 157/9) b) that systems using this mode of propagation are already in service for burst data transmission,

A Measurement of 3-D Water Velocity Components During ROV Tether Simulations in a Test Tank Using Hydroacoustic Doppler Velocimeter

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Silicon Sensors for CMS Tracker at High-Luminosity Environment - Challenges in particle detection -

ISC Dual Frequency WFS RFPD Test Procedure:

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps :1 > 70 % pco. low noise high resolution high speed high dynamic range

Transcription:

IMPROVED CCD DETECTORS FOR HIGH SPEED, CHARGE EXCHANGE SPECTROSCOPY STUDIES ON THE TOKAMAK by K.H. Burrell P. Gohil, R.J. Groebner, D.H. Kaplan, D.G. Nilson,* J.I. Robinson, and D.M. Thomas General Atomics, San Diego, California *Lawrence Livermore National Laboratory, Livermore, California Presented at Workshop on Scientific Detectors for Astronomy Waimea, Hawai i June 16 22, 2002 QTYUIOP 168 02/KHB/wj

INTRODUCTION The ultimate goal of fusion research is to establish a burning plasma where the energy needed to sustain the plasma comes from its own fusion reactions From the standpoint of a spectroscopist, the tokamak plasmas utilized in magnetic fusion research provide a wonderful light source Ion temperatures up to 27 kev and electron temperatures up to 10 kev are routinely available for several seconds in the tokamak Electron densities are typically in the 1 10 10 19 m 3 range Spectroscopic measurements of Doppler broadening, Doppler shift and intensity of radiation from highly ionized atoms allows us to determine Ion temperature T i Poloidal and toroidal rotation speeds Vθ, Vφ Density n of a given ion Radial electric field E r (via radial force balance equation) By utilizing charge exchange excitation from the 80 kev D 0 neutral beams used to heat the plasma, we can perform spatially localized measurements To date, we have used various H-like and Li-like ions: D I, He II, C IV, C VI, O VIII, F IX, Ne X, Ar XVI, Ar XVIII, Ca XXVIII, and Ca XX D, He, C, and O are naturally present in the plasma; F, Ne, Ar, and Ca have been injected to study particle transport Measurements are made at 40 spatial points using fiber optics to couple light to the spectrometers

SUMMARY For the 2000 experimental campaign, we replaced the intensified linear photodiode detectors on the 16 edge views with advanced CCD detectors mounted on faster (f/4.7) Czerny-Turner spectrometers equipped with toroidal mirrors PixelVision Pluto cameras based on SITe O-18A chip were used Photoelectron signal has increased by a factor of 20 and signal to noise by a factor of 2 to 8, depending on signal level and CCD readout mode Major portion of signal level improvement comes from increased quantum efficiency (70% to 85% versus 10% for intensifier) Improved spectrometers account for the rest of the signal increase Minimum integration time is 0.32 ms while archiving to PC memory and 0.15 ms using temporary on-chip storage of spectra We are now in the process of upgrading another 16 views of the spectroscopic system to CCD detectors This upgrade will use PixelVision cameras with SITe O-18B chip

TOKAMAK Ohmic Heating Transformer that generates the high currents in the plasma which produce a plasma stabilizing magnetic field Field Shaping Coils that produce the magnetic fields that keep the plasma centered in the chamber Toroidal Field Coils that produce the main magnetic field (toroidal field) that suspends the high temperature plasma away from the vacuum vessel Ports where diagnostics are mounted to measure plasma properties Plasma Vacuum Vessel to prevent air from contaminating the fusion fuel (plasma) Graphite Armor to protect the vacuum vessel from the hot plasma Divertor removes heat and exhausts particles from plasma

DII-D PLASMA PARAMETERS Parameter Simultaneous Maximum DIII-D TOKAMAK PARAMETERS Major Parameters Plasma Major Radius R 1.67 m Electron Temperature T e 7.5 kev 16 kev Ion Temperature T i 18 kev 27 kev Plasma Minor Radius a Maximum Plasma Height 0.67 m 2.8 m Density n e 1.0 10 20 m 3 1.7 10 20 m 3 Elongation κ 1-2.5 Confinement Time τ E 0.4 s 0.5 s Plasma Current I P 2.25 MA 3.0 MA Stored Energy W 4.2 MJ 4.2 MJ Beta β 6.7% 13% Normalized Beta β N 3.9 6.0 Fusion Product nτt i 7 10 20 kev s m 3 7 10 20 kev s m 3 Magnetic Field B T Fuel Gas Heating Power to Plasma Neutral Beam Electron Cyclotron Wave Ion Cyclotron Wave Operating Mode Pulsed, Every Pulse Duration 2.1 T D, H, He 16 MW 3 MW 4 MW 12 min. 5 10 s

PLAN VIEW OF CER CHORDS Vertical Direction Edge Vertical Array Centerline of Neutral Beam R major = 226.6 cm ~6 mm ~6 mm R major = 231.0 cm Horizontal Direction Edge Tangential Array 360 0 330 Neutral Beams EDGE Tangential Viewing Chords 30 Neutral Beam EDGE Vertical Viewing Chords Central Vertical Viewing Chords Central Tangential Viewing Chords Inner Wall 270 Outer Wall 90

VERTICAL VIEW OF CER CHORDS EDGE Vertical Chords Central Tangential Chords EDGE Tangential Chords Central Vertical Chords

DETECTOR HISTORY When we developed the charge exchange spectroscopy system originally in 1985, we obtained the speed we needed using detectors based on image intensifiers fiber optically coupled to linear silicon diode arrays We pushed this technology to its limits, obtaining 0.52 ms readout times of 1024 diode Reticon linear arrays In the mid-1990 s, CCD technology finally developed to the point where it was superior to intensifier-linear diode array combinations, even under conditions where sub-millisecond integration times are needed We developed a detector system based on the Sarnoff VCCD512 chip Minimum integration time was 0.38 ms using a 1 MHz readout of the serial register However, in spite of several years development effort, system read noise was about 75 electrons, much worse than the 35 45 electrons promised in the specifications Basic board set was from Sarnoff; General Atomics did system integration In the late 1990 s, complete commercial scientific CCD camera systems became available System integration performed by vendor Complete camera cost the same as Sarnoff board sets Data acquisition to inexpensive PC instead of expensive CAMAC digitizers and Unix workstation

DESIGN PHILOSOPHY Detector performance must exceed that of the previous intensifier-linear diode array system by a large margin to make the development effort worthwhile Signal and signal to noise should be well above those achieved in the previous system Quantum efficiency should be well above the 10% available with standard image intensifiers Minimum integration time should be well below 0.52 ms Design for highest possible light throughput and highest possible quantum efficiency Requires a back illuminated, thinned CCD chip Use as low an f/number spectrometer as commercially available Continue to use commercial Czerny-Turner spectrometer for ease of setting wavelength Some of the lines used in experiments: D I 656.2 nm, He II 468.6 nm, B V 494.47 nm, C VI 343.37 nm, C VI 529.05 nm, C VI 771.68 nm, F IX 479.4 nm, F IX 342.9 nm, Ne X 524.90 nm, Ar XVI 346.3 nm, Ar XVIII 344.9 nm, Ca XVIII 344.9 nm, Ca XX 346.3 nm

CCD HAS MULTIPLE READOUT MODES PixelVision CCD camera is controlled with a flexible digital signal processing system which allows various software selectable readout modes Image mode allows readout as a standard 2-D imager Very convenient for aligning camera to spectrometer Used with PixelVision-provided software on PC Much too slow for tokamak spectroscopy TDI mode: standard tokamak spectroscopic mode When external trigger occurs, charge in exposure area on chip is clocked to the storage areas Two storage areas, one for upper and one for lower half of chip At the same time, all 251 pixels in each column of each storage area are binned on to the serial readout register Serial register is then read out at either 0.5 MHz or 2.2 MHz digitizing rate; left and right halves of both registers are digitized separately (4 output channels total) Data is archived to PC memory; number of spectra limited only by PC memory 0.32 ms minimum integration time at 2.2 MHz, 0.82 ms at 0.5 MHz 30 electrons readout noise at 2.2 MHz, 15 20 electrons at 0.5 MHz Sample mode When external trigger occurs, charge in exposure area is binned onto the first row of the storage area Storage area is clocked once to move charge to next row Cycle repeats until storage area is full Storage area is then read out one row at a time at 0.5 MHz digitizing rate Only 254 spectra can be stored in storage area 0.15 ms minimum integration time 15 20 electrons readout noise

QUANTUM EFFICIENCIES OF BACK ILLUMINATED CCD CHIPS 100 Quantum Efficiency vs. Wavelength @ Room Temp. Quantum Efficiency, % 80 60 40 20 SITe 0-18B SITe 0-18A 0 200 300 400 500 600 700 Wavelength, nm 800 900 1000 1100

COUPLING CCD CAMERAS TO SPECTROMETERS Initial desire was to use a 1024 x 1024 Pluto chip Large enough to take four spectra Would require one camera per spectrometer Chip was never available in commercial quantities 652 x 488 0 18 A chip was available in 1999, but only has one third the area of the 1024 x 1024 chip Because of broad wavelength range needed in our system (300 to 800 nm), optics to couple the output of the spectrometer to the smaller chip would have been complicated and expensive It was significantly cheaper to buy more cameras to get the necessary area Planar mirror coupling arrangement shown below is simple, robust and works over the required wavelength range This design required boring hole in spectrometer s removable hatch In principle, this coupling scheme could be done with one mirror One mirror design would require milling a 120 mm wide slot in the body of the spectrometer to accommodate the bodies of the CCD cameras

SIDE VIEW OF SPECTROMETER, DIVERTOR MIRRORS AND CCD CAMERAS Support Frame Divertor Mirrors Translation stages for 3-axis linear motion and 1-axis azimuthal motion Pixelvision Camera 1 Pixelvision Camera 2 Spectrometer Light Path Divertor Mirror Toroidal Mirror

Translation Stages Mount for Prism Mirror Cameras Spectrometer

SCHEMATIC DIAGRAM OF PIXELVISION CAMERAS AND COMPUTERS LAYOUT EDGE VERTICAL SYSTEM (8 CHORDS: V9 V16) EDGE TANGENTIAL SYSTEM (8 CHORDS: T9 T16) Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Camera 1 V9, V11 Camera 2 V13, V15 Camera 3 V10, V12 Camera 4 V14, V16 Camera 5 T9, T11 Camera 6 T13, T15 Camera 7 T10, T12 Camera 8 T14, T16 Optical links for data, control and triggers Optical links for data, control and triggers PCI board 1 PCI board 0 PCI board 1 PCI board 0 PCI board 1 PCI board 0 PCI board 1 PCI board 0 DELL PC (PV2) DELL PC (PV3) DELL PC (PV4) DELL PC (PV5) Ethemet link (100baseT) Computer Network

TOROIDAL MIRROR FOR ACTON SPECTROMETER Standard Czerny-Turner spectrometers use spherical mirrors; this leads to astigmatism with tangential (wavelength-direction) and sagittal (vertical) focal planes being different Offset by 12 mm at center of exit plane Tilted about 1 degree Vertical blurring at best wavelength focus reduces number of spatial chords which can be imaged on a given detector without cross talk Techniques used previously to reduce this blurring cost signal Toroidal mirror for first (collimating) mirror in spectrometer can reduce astigmatism Focal planes meet along a line in middle of exit planes Focal planes are still tilted, but this produces very small blurring over 7.8 mm width of detector Signal improved about a factor of two over system without toroidal mirror

PIXELVISION CAMERA s SIGNAL TO NOISE IS SIGNIFICANTLY BETTER THAN INTENSIFIED DIODE ARRAY s Signal proportional to DQ/f 2 D is dispersion (pm/pixel) (CCD system 15.6; intensifier system 11.62) Q is quantum efficiency (CCD system 0.75; intensifier system 0.1) f is spectrometer f/number (CCD system 4.7; intensifier system 6.8) Binned serial output on CCD system to produce 326 pixels with 15.6 pm/pixel dispersion Result is factor 20 improvement for new CCD system over intensified diode system New system noise estimate (S e + r 2 e ) 1/2 S e is signal in photoelectrons r e is read noise in electrons Intensifier system noise estimate (3.24 S e + r 2 e ) 1/2 Factor 3.24 = 1.8 2 is due to amplification in intensifier Signal to noise ratio improvement For small signal levels: 2 for 2.2 MHz readout speed and 4 for 0.5 MHz For large signal levels: 8 for both readout modes

BACKGROUND LEVEL DRIFT AND REFRESH CIRCUITRY The dark current and dc offset contributions must be subtracted from the total digitized value to obtain the signal due to photo electrons The dark current and dc levels showed unexpected changes when the external triggers start or when the interval between the triggers changes This can amount to many 10 s of digitizer counts Level can take several seconds to stabilize when external triggers first start Level change stabilizes in a fraction of a second when the interval between triggers changes (e.g. from 10 ms to 1 ms) To minimize background level change, we implemented control electronics which repetitively trigger the cameras at 10 ms intervals between tokamak shots Tokamak synchronous triggers take over during shot We have implemented software to record a complete set of background data with timing duplicating the tokamak timing We fit an interpolation function to this and archive the parameters of the interpolation function Initial functional form was simply linear Working on a form which adds a decaying exponential to the linear fit

NEUTRON/GAMMA REJECTION Because of D-D fusion reactions in the tokamak plasma, neutron and gamma radiation is present in our spectrometer room Maximum neutron rate is up to 10 16 /s next to tokamak Shielding has been installed to reduce the neutron/gamma hits on the CCD detectors Enough has been installed to reduce the neutron/gamma hits on the detectors to a maximum rate of a few hits in 10 ms This consists of the main shielding surrounding the whole tokamak plus local shielding for each spectrometer Complete shielding would be expensive and make access to the equipment extremely difficult Software is used to identify pixels whose signals are polluted by neutron/gamma hits and these are ignored in the analysis which computes temperature and rotation Neutron/gamma spikes are typically much more localized than the spectrometer instrumental response and have more rapid pixel to pixel variation These differences are used as the basis for the software rejection algorithm

HIGH TIME RESOLUTION CER MEASUREMENTS SHOW DETAILED EFFECTS OF PULSED MHD INSTABILITY (ELM) ON EDGE PLASMA Intensity (1017 ph/m 2 s sr) Temperature (kev) 5 4 3 2 1 R R s (cm) 4.9 1.4 0.1 0 2700 2702 2704 2706 1.5 1.0 0.5 2.0 0.8 +1.2 2708 2710 0.0 2700 2702 2704 2706 2708 2710 Time (ms) Toroidal Velocity (km/s) 60 40 20 0 2700 2702 2704 2706 2708 2710 0.020 Divertor D α 0.015 0.010 0.005 0.000 2700 2702 2704 2706 2708 2710 Time (ms)