Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions



Similar documents
What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Supplementary Materials and Methods (Metabolomics analysis)

Overview. Purpose. Methods. Results

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns

Oasis HLB Cartridges and 96-Well Plates

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Development and Validation of a LC-MS/MS Method for Plasma Analysis of the Serotonin Metabolite: 5-Hydroxyindoleacetic acid (5-HIAA)

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Rapid LC/MS/MS Method Development for Drug Discovery

How To Test For Contamination In Large Volume Water

How To Develop A Recipe Card

Chemical analysis service, Turner s Green Technology Group

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

LC-MS/MS for Chromatographers

Analytical Test Report

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Waters Core Chromatography Training (2 Days)

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

S olid Ph ase Extraction (SP E) Method:

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

SUPPLEMENTARY FIGURES

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

CORESTA RECOMMENDED METHOD N 72

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Fatty acid amide hydrolase (FAAH) inhibition reduces L-DOPA-induced hyperactivity in. the MPTP-lesioned non-human primate model of Parkinson s disease

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

LC-MS/MS STRATEGIES FOR QUANTIFICATION OF THERAPEUTIC ANTIBODIES TO SUPPORT CLINICAL

A Novel Approach to Low Volume Sample Preparation

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Q-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

High Sensitivity MS Determination of Carryover in a New Autosampler Design

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

LC-MS/MS Solutions for the Pharmaceutical and CRO Industries TSQ Series -based Solutions for Drug Discovery and Development

8. SUMMARY AND CONCLUSION

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

AppNote 7/2009. Analysis of Drugs of Abuse using Automated Disposable Pipette Extraction and LC/MS/MS KEYWORDS ABSTRACT

SpikeTides TM Peptides for relative and absolute quantification in SRM and MRM Assays

METHOD OF ANALYSIS. N methyl 2-pyrrolidone

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

An In-Gel Digestion Protocol

Chromium Speciation in Drinking Water by LC-ICP-MS

Ádám Tölgyesi Joerg Stroka. Report EUR EN

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Guidance for Industry

WATERS QUANTITATIVE ANALYSIS solutions

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

Structural Analysis of Labeled N-Glycans from Proteins by LC-MS/MS Separated Using a Novel Mixed-Mode Stationary Phase

Peptide synthesis, radiolabelling and radiochemical analysis

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Quantitative Analysis of Explosives in Surface Water Comparing Off-Line Solid Phase Extraction and Direct Injection LC/MS/MS

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Matrix Effect in Bio-Analysis of Illicit Drugs with LC-MS/MS: Influence of Ionization Type, Sample Preparation, and Biofluid

Introduction. Methods. Sample Processing

Transcription:

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions authors Angela (Qi) Shen, Ling Morgan, Marcele L. Barroso, and Xin Zhang; Tandem Labs Tuyen Nguyen; Sepracor Inc. introduction The aminoglycosides are mainstream drugs used in the treatment of serious gram-negative systemic infections. They irreversibly bind to the ribosome site and other cellular structures in order to interrupt the protein synthesis. The common feature of these drugs is an aminocyditol ring linked to an amino sugar in the structure. Therefore, these drugs are highly soluble in water, exhibit low plasma protein binding, and are more than 90% excreted through the kidney. Herein, we share our experiences with LC-MS/MS method development for the analysis of aminoglycosides in plasma samples with HILIC and ion pairing chromatography. OBJECTIVE To develop a reliable and generic LC-MS/MS method to quantify the aminoglycoside class of drugs. approaches Sample Generation 1. Sample Matrix: Mouse, Rat and Guinea Pig Plasma with K 2 EDTA as the anti-coagulant. (Spiking solution approach was employed in the preparation of all standard and QC calibrants.) 2. Sample Treatment: Acid treated plasma samples underwent protein precipitation with a ratio of 1:6, Sample:Acetonitrile. (Cold internal standard prepared in Acetonitrile was preferred to generate cleaner sample extract for LC-MS/MS analysis.) The transferred supernatant was dried down and reconstituted with 1% Formic Acid (FA) in water, or initial MPA/MPB composition of LC conditions. 3. Internal Standard: Vancomycin and glyburide. Angela (Qi) Shen et al. (2008) 1

LC Conditions Two types of LC conditions were employed for the analysis: ion pairing chromatography and HILIC. (See details in each respective section.) MS Conditions MRM mode and electrospray ionization mode (ESI), in positive, were employed for all analytes. Amikacin: 586.7 > 163.2; Streptomycin: 582.7 > 263.2 Spectinomycin: 333.2 > 98.0; Gentamicin: 478.6 > 160.3 Vancomycin: 724.8 > 144.2; Glyburide: 494.5 > 369.1 Data Acquisition API4000 or API5000, utilizing ESI mode, were needed for required LLOQs for each analyte under different experimental conditions. Analyst 1.4.2 was used for regression and linearity calculations.results AND DISCUSSION Figure 1. Model Compound Chemical Structures Angela (Qi) Shen et al. (2008) 2

results and discussion Sample Preparation Nonspecific Binding: Initially, an inconsistent LLOQ was obtained during amikacin analysis. Investigational experiments were conducted and revealed non-specific binding for all four compounds. Table 1. A brief summary of the situations tested 1. 2. 3. All four compounds exhibit severe binding to glass vials after four consecutive transfer steps among four regular 4mL glass vials. All four compounds bind to plastic tubes. Gentamicin and amikacin are more severe than the other two. Addition of organic acid, such as 1% FA in stock solution eases the non specific binding to glass vials, as well as plastic tubes and 96 well plates. Acid Treatment Simple protein precipitation was used with a ratio of 1:6, Sample:Acetonitrile. (Cold internal standard in Acetonitrile solution is preferred to generate cleaner sample extract for LC-MS/MS analysis.) Acidification of samples prior to PPT proved to be the key step for good recovery. Angela (Qi) Shen et al. (2008) 3

Figure 2. Initial Result of Treatment of Plasma Sample with Acid Optimization: After a series of experiments, 10% v:v of 3N HCl was determined to be a suitable choice for minimum sample volume of 25µL. After PPT, the sample supernatant was transferred and dried down. Initial LC composition of MPA/MPB was determined the preferred choice for the re-con solution Figure 3. Selective Ion Pairing Chromatograms: untreated versus acid treated Angela (Qi) Shen et al. (2008) 4

HILIC Condition: Mobile Phases: 1. MPA: 5 or 25 mm Ammonium Formate in Milli-Q water with Formic Acid (ph = ~2.5) 2. MPB: Acetonitrile with 1% (v:v) Formic Acid HPLC Column: SeQuant Zic-HILIC 50 X 2.0 mm, 5 µm particle size. Flow Rate: 600 µl/min Gradient Profile: Hold initial 90% of MPB for 0.5 minutes; decrease to 10% of MPB at 1.0 minute; retain at 10% of MPB for 3 minutes; return to 90% of MPB for column conditioning. Figure 4. HILIC: Impact of Different Concentrations of Ammonium Formate: 20 mm vs 5 mm (ion suppression) Decreasing the concentration of Ammonium Formate from 20 mm to 5 mm in MPA improved the MS response for all analytes due to ion suppression reduction. On the other hand, such change had negative impact on the chromatography for gentamycin analysis. Angela (Qi) Shen et al. (2008) 5

Table 2. Summary of LLOQ for Four Compounds Under Different Conditions Ion Pairing Chromatography 1. 2. Mobile Phases: MPA: 10 mm Nonafluoropentanoic Acid with 10 mm Ammonium Hydroxide in Milli-Q water. MPB: 5 mm Nonafluoropentanoic Acid with 5 mm Ammonium Hydroxide in 10:90 mixture of Milli-Q water:acetonitrile HPLC Column: Agilent Zorbax SB-C8 30 X 2.0 mm, 5 µm particle size. Flow Rate: 500 µl/min Gradient Profile: Hold initial 20% of MPB for 0.5 minutes; increase to 90% of MPB for 2.4 minutes; retain 90% of MPB for 0.5 minutes; return to 20% of MPB for column conditioning. Figure 5. Ion Pairing Chromatography Angela (Qi) Shen et al. (2008) 6

The major advantage of the employment of ion pairing chromatography is the improvement of the detection limit for all analytes by 10 fold (see Table 2). In addition, ion suppression phenomenon is manageable (data is not shown here). We did observe column related carry-over issues. The detail is summarized in Table 3 below. Table 3. Summary of Carryover Evaluation conclusion We report two different LC-MS/MS approaches for the analysis of aminoglycosides using ion pairing and HILIC. Care must be taken during the sample preparation step, since severe non-specific binding to glass and some binding to plastic were observed. Pre-treating the sample with acid is critical for good compound recovery from the samples. Both ion pairing and HILIC demonstrate good chromatography for majority of compounds tested. We also observed that ion pairing chromatography demonstrated better detection limits for three of the compounds. Both ion pairing and HILIC have comparable detection limits for Spectinomycin. Further optimization of HILIC conditions to improve sensitivity is needed for all compounds. Angela (Qi) Shen et al. (2008) 7

Tandem labs Tandem Labs is a leading bioanalytical and immunoanalytical contract research organization (CRO) supporting pharmaceutical and biotechnology companies with their discovery, preclinical, and clinical drug development programs. Our laboratory menu includes advanced mass spectrometry, immunoanalytical support, pharmacokinetics, and pharmacodynamics. We also provide clinical research services through our strategic partner. Download more posters and white papers at our website www.tandemlabs.com/capabilities_publications Find full contact information online www.tandemlabs.com/contact Tandem Labs-Utah 1121 East 3900 South Building C, Suite 105 Salt Lake City, UT 84124 (801) 293-2400 Tandem Labs-New Jersey 115 Silvia Street West Trenton, NJ 08628 (609) 434-0044 Tandem Labs-New England 35R Cabot Road Woburn, MA 01801 (781) 933-2769 x 123 Angela (Qi) Shen et al. (2008) 8