IPSIP M series-m Modular Data Center



Similar documents
Huawei IDS2000 Modular Data Center Solution

Huawei IDS1000 Container Data Center Solution

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

High-density modular data center making cloud easier. Frank Zheng Huawei

JAWAHARLAL NEHRU UNIVERSITY

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

RiMatrix S Make easy.

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

How To Build A T7 Rack For Information Technology

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Huawei Data Center Facility Integration Solution

Technical specifications. Containerized data centre NTR CDC 40f+

Scalable. Affordable. Flexible. Fast.

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Managing Data Centre Heat Issues

Huawei Cloud and Virtualization introduction HUAWEI TECHNOLOGIES CO., LTD.

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

Data Center Solutions - The Containerized Evolution

APC APPLICATION NOTE #112

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Eaton 93PM UPS Where aesthetics meet intelligence.

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

Data Center Components Overview

THE WORLD S MOST EFFICIENT DATA CENTER

In Row Cooling Options for High Density IT Applications

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Automation's Modular Containerized Datacenter Solutions

Portable Energy Efficient Data Centre Solution

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

All-in-one Container Data Center solution HUAWEI TECHNOLOGIES CO., LTD.

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Choosing Close-Coupled IT Cooling Solutions

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

AIRAH Presentation April 30 th 2014

NAISSUS THERMAL MANAGEMENT SOLUTIONS

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

Phase Modular Finally the benefits of Modular ups are for all

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

APC APPLICATION NOTE #92

Data Centre Testing and Commissioning

POD S in Data Centres. The Frame Group Pty Ltd

CANNON T4 MODULAR DATA CENTRE HALLS

DIGITUS Network & Server Cabinets. UNIQUE Series

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

INFRASTRUCTURE FOR DATACENTERS

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

EHDC. Cooling system for Data Center and server cabinets.

The Pros and Cons of Modular Systems

White Paper Rack climate control in data centres

As close to perfection. development and production. Modular data center

SERVER ROOM CABINET INSTALLATION CONCEPTS

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Energy Efficiency and Availability Management in Consolidated Data Centers

COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION

Cisco Nexus 7000 Series Power Supply Modules

opdc Cut your data center OPEX upto 70%

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

BRUNS-PAK Presents MARK S. EVANKO, Principal

Colt Colocation Services Colt Technology Services Group Limited. All rights reserved.

Case Study: Guaranteed efficiency through standardised data centres

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

ECOCIAT. Domestic hot water heat recovery unit

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Airflow Simulation Solves Data Centre Cooling Problem

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

PowerGem Pro Uninterruptible Power Supply

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

The Mission Critical Data Center Understand Complexity Improve Performance

DataCenter 2020: first results for energy-optimization at existing data centers

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

FULL DC INVERTER SYSTEMS

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Cisco Redundant Power System 2300

Rittal Liquid Cooling Series

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

How to Meet 24 by Forever Cooling Demands of your Data Center

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Building a data center. C R Srinivasan Tata Communications

AU-110 racking guide NBXPN: 023

Galaxy VM. Three-phase power protection. schneider-electric.com

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Transcription:

IPSIP M series-m Modular Data Center IPSIP MODULAR TECHNOLOGIES.

1

With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption are bringing a lot, as well as improving the efficiency of data centers, accelerating the speed of deployment,and controlling investment and operating costs, IPSIP Modular has launched the M Series-M modular data center solution. M Series M is a new generation modular data center solution with complete integration of cabinets, power supply and distribution systems, cooling systems, cabling systems, management software, and much more. IPSIP Modular M Series-M modular data center adopts All-in-room integration design. It supports flexible deployment with single or dual row, contained or non-contained aisle, cold or hot aisle containment. Maximum 48 cabinets can be deployed in dual-row module and 18 cabinets in single-row module with 3~36 IT cabinets. The maximal IT power can be up to 21kW/ rack. Single module is suitable for the space below 100m2.. M Series-M module data center has been widely applied in small and medium enterprises as well as the branch of large corporation in government,education, healthcare, finance industry etc, and medium capacity desktop cloud computing and high-performance computing data center. Customer Value: Fast deployment All in room design, a single room integrates cabinets, confined aisle, power supply and distribution system, cooling system and management system. Factory prefabrication and standardized interfaces makes installation within 1 week and deployed period saving up to 50% High adaptability Maximizing the space utilization by flexible deployment of single-row or dual-row for diversified rooms Support concrete floor or raise height floor installation, only a 2.6 m net height is required Efficient & modular design Modular structure makes scalable expansion and Capex saving up to 30% Associate with In-row cooling, modular UPS, aisle containment and highly integrated PDU cause the PUE lower than 1.5 Intelligent management IPSIP Modular NetEco management system can monitor all data center facility uniformly including electricity, environment, video, access control etc The comprehensive intelligent management platform provides functions such as alarm management, report management, capacity management, energy efficiency management, resource management, 3D view realizes precise management, simple operation and maintenance and energy saving 2

Two types of cable troughs: signal cable troughs and power cable troughs. Cables insulation reduces system interference and increase reliability. Cable holes are located in the center of each cabinet top cover to simplify cable-routing into the cabinet. The expansion of length direction can be achieved. Cabling Skylight A flat roof ceiling consists of side panels, top frames, and revolving ceiling panels. The temperature detector and smoke alarm are installed in containment aisle, and are linked with skylight controller. After the action of electromagnetic switch, the rotate skylight automatically opens by gravity, ensuring the fire extinguishing gases into the aisle. End door The end door of a confined channel can be a sliding door or a double door. Tempered glass is used as the door panel, which ensures channel visibility and meets fire fighting requirements. Sealed brushes are installed at the bottom of the door panel, making the date center module sealed in an enhanced manner. The access control system is optional when a double door is used. Power system Power Distribution - PDF PDF includes integrated PDF and combined PDF (UPS PDF and precise PDF). 380/400/415V (3Ph, 50/60Hz) are all supported. UPS PDF integrated ATS, UPS power supply and air conditioner power supply, and precise PDF mainly provides power and energy measurement for IT load. Power Supply - UPS The UPS provides an uninterruptible power supply for the modular data center. 380/400/415V (3Ph, 50/60Hz) are all supported. According to Tier II, Tier III, Tier IV demands, power supply system is in the N, N+1, 2N backup. 3

NetEco system NetEco system manages the real-time data and status of data center infrasturctures, including power, environment, video, and door status. Handling emer gencies automatically, impr oving management efficiency greatly, reducing the cost of O&M. Dynamic PUE management, optimizing important power and cooling services, smart interaction with cloud-platform. Fire system FM200 heptafluoropropane gas is equipped, module containment is installed with smoke temperature sensors, when the smoke sensor and temperature sensor are warning at the same time, then the fire control system push gas into module; External smoke sensor, and temperature sensor fixing bracket are available, and the height is adjustable to realize fast free-engineering (when not using the fixing bracket, sensors can be directly installed on the ceiling). Cooling In a modular data center, air conditioners and racks form cold /hot aisles for isolation between cold air and hot air. Row-level ACs are close to the heat sources, which reduces the air pressure losses and minimizes cold air leakage to maximize the use of cold air. The cooling supply system is in the 'N+X' backup, which complies 'Tier III', and for higher reliability, the 'Tier IV' could be also customized. Rack One modular data center consists of 48 server racks at most. Racks are unified in dimension, and complied with 19-inch standard, and the air ventilation is front-to-rear, and the doors' perforation rate is 67%. Super bearing load: static load is1200 kg. All racks are pre-installed in factory, which make on-site implementation much faster. 4

IDS2000-M Specifications Item Specifications 300mm single-row with aisle containment: L x 1560mm x 2180mm, L 10800mm 1200mm single-row with aisle containment: L x 2400mm x 2350mm, L 10800mm Number of IT racks per module Single row: 12; dual row 36 Dual-row with aisle containment: L x 3600mm x 2350mm, L 14400mm System Input Power IT Power Consumption Maximum power per rack Operating Condition Reliability level 208/220V (3Ph, 60Hz) 380/400/415V (3Ph, 50/60Hz) 440/460/480V (3Ph, 60Hz) 208V: 15~75kVA 380V: 10~200kVA 480V: 80/120kVA 21kW T1 condition: 30ºC ~ +45ºC; T3 condition: 20ºC ~ +55ºC Tier II or Tier III (up to Tier IV) Altitude 0 ~ 1000m (derating above 1000m) Cabinet Air-cooled In-row Air Conditioner Chilled water In-row Air Conditioner Rack-mounted UPS Modular UPS Installation (H x W x D) Installation space Protection level Cooling capacity (H x W x D) Input power Refrigerant Cooling capacity (H x W x D) Input power Refrigerant Input power Rated capacity Input power Rated capacity Installing on concrete floor or raised floor 2000mm x 600mm x 1200mm/2200mm x 600mm x 1200mm 42U/47U IP20 25kW/35kW 2000mm x 600mm x 1100mm 380/400/415V (3Ph, 50/60Hz),440/460/480V (3Ph, 60Hz) R410A 30kW 2000mm x 300mm x 1200mm 200~240V (1Ph, 50/60Hz) Water / Ethylene Glycol 380V (3Ph, 50/60Hz) 10/15/20kVA 380V (3Ph, 50/60Hz) 40/80/120/160/200kVA 5

IPSIP Modular NetHos cabinet NetHos series cabinet which is reliable, safe, compatible and environment-friendly, meets different scenarios of modular data centers. Safety and reliability Complied with IEC 60297-1 standard, adjustable distance between the front and the rear mounting bars Stable Structure Design Super bearing load: static load is1200 kg Good heat dissipation The doors' perforation rate is 67%, to ensure the smooth air ventilation Good compatibility Standardized design, compatible with different 19-inch equipment Flexible expansion Using connection fittings, to support cabinets mounted side by side Professional power distribution solutions Professional cabinet-level power system, providing various types of power distribution solutions A two-section side panels The side panels are fixed with tools, easy for installation, transportation and disassembly Perfect cable management Top or bottom wiring is optional with cable through on top Division Design On-demand deployment for different businesses and different densities 6

IPSIP Modular UPS series UPS2000-G series (1/3/6/10/15/20kVA) UPS5000-E series (40/80/120/160/200/240/280/320kVA) UPS5000-A series (30/40/60/80/120/200/300/400/500/600/800kVA) UPS8000-D series (200/300/400/500/600kVA) Reliable Efficient Convenient Intelligent A strong know-how support system to safeguard up to 1,000,000+ IPSIP Modular power system under the harsh and severe environments Tests performed under the extreme environment conditions, i.e. Airborne Hygroscopic Dust Test(AHD) and Long Life Test(LLT) The key components used are provided by Top 3 suppliers High efficiency at online mode: up to 96% High efficiency at low load rate enables IPSIP Modular UPS to reduce power loss even at parallel configuration Globally, IPSIP Modular UPS has achieved Energy Star qualification in the first batch Modularization, ease of expansion Standardization, ease of identification Integration, ease of delivery Fault-tolerant, ease of maintenance A built-in real-time operating system offers reliability and flexibility Real-time monitoring on battery parameter and automatic temperature compensation NetEco smart network to cover all power supply nodes 7

IPSIP Modular precision air conditioner series NetCol5000-A series Air-cooled in-row precision air conditioner (25/35kW) NetCol5000-C series Chilled-water in-row precision air conditioner (30kW) NetCol8000-A series Air-cooled in-room precision air conditioner (50/100kW) NetCol8000-C series Chilled-water in-room precision air conditioner (50/70/120/150kW) Efficient Reliable Intelligent Green Component-level energy saving: Integrated high efficiency DC inverter compressor, EC fan, power supply module etc Unite-level energy saving: CFD simulation, field synergy design, optimized matching System level saving: Function such as cascading, rotation and operation mode of avoiding competition Key component are in redundancy design Wide operating temperature range: -20ºC ~ +55ºC Lightning filtering board designs, adapts for extreme mains CAN communication protocol realizes accurate control of air conditioner s parameters Linkage and group control function can control up to 32 air conditioners One-key fault information collection, clearly display fault reason and maintenance strategy R410A environment friendly refrigerant with high efficiency RoHS complied 8

M Series-M Typical Products 20KVA M020-4D-4 UPS capacity 20kVA Number of IT racks 4 Power density 4kW/R 3.6m 3m M020-4S-4 UPS capacity 20kVA Number of IT racks 4 Power density 4kW/R 1.5m 6m M020-5D-3 UPS capacity 20kVA Number of IT racks 5 Power density 3kW/R 3.6m 3.6m M020-5S-3 UPS capacity 20kVA Number of IT racks 5 Power density 3kW//R 1.5m 6.6m Note: M020-4D-4: M: modular data centers; -: hyphen; 020: main UPS capacity 20kVA; 4: number of IT racks; D: single or dual row (D: dual-row aisle; S: single-row aisle); 4: IT power per rack is 4kW 9

M Series-M Typical Products 30KVA M030-6D-4 UPS capacity 30kVA Number of IT racks 6 Power density 4kW/R Backup time 40min 3.6m 3.6m M030-6S-4 UPS capacity 30kVA Number of IT racks 6 Power density 4kW/R Backup time 40min 1.5m 7.2m M030-8D-3 UPS capacity 30kVA Number of IT racks 8 Power density 3kW/R Backup time 40min 3.6m 4.2m M030-8S-3 UPS capacity 30kVA Number of IT racks 8 Power density 3kW/R Backup time 40min 1.5m 8.4m 10

M Series-M Typical Products 40KVA and 60KVA M040-5D-5 UPS capacity 40kVA Number of IT racks 5 Power density 5kW/R 3.6m 3.6m M040-5S-5 UPS capacity 40kVA Number of IT racks 5 Power density 5kW/R 1.5m 7.2m M040-8D-4 UPS capacity 40kVA Number of IT racks 8 Power density 4kW/R 3.6m 4.8m M060-8D-5 UPS capacity 60kVA Number of IT racks 8 Power density 5kW/R 3.6m 5.4m 11

M Series-M Typical Products 80KVA and 120KVA M080-11D-5 UPS capacity 80kVA Number of IT racks 11 Power density 5kW/R Backup time 15min 3.6m 6m M080-7D-9 UPS capacity 80kVA Number of IT racks 7 Power density 9kW/R Backup time 15min 3.6m 4.8m Note: The dimensions do not include external power area M120-10D-9 UPS capacity 120kVA Number of IT racks 10 Power density 9kW/R 3.6m 5.4m Note: The dimensions do not include external power area M120-17D-5 UPS capacity 120kVA Number of IT racks 17 Power density 5kW/R 3.6m 7.2m 12