HOMER Analyzer ISM 2.45 GHz, R-26 Waveguide

Similar documents
One Port Network Analyzer

Impedance 50 (75 connectors via adapters)

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

R&S ZCxxx Millimeter-Wave Converters Specifications

USB Smart Power Sensor

R&S ZNBT8 Vector Network Analyzer Specifications

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

EFC Frequency converters

Waveguide Access Point WGA631. Product Guide

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

Vibration analysis and monitoring Compact. Powerful. Modern technology.

EVAL-UFDC-1/UFDC-1M-16

USB Smart Power Sensor

DRO Function guide: Zero setting 1/2 calculation mm/inch conversion INC/ABS conversion

R&S SMZ Frequency Multiplier Specifications

Six-Port Reflectometer: an Alternative Network Analyzer for THz Region. Guoguang Wu

R&S ZVA Vector Network Analyzer Specifications

High Power Programmable DC Power Supplies PVS Series

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Energy Management Energy Meter Type EM23 DIN

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Measuring Laser Power and Energy Output

Continuous, remote monitoring and logging of electromagnetic fields

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Multi-Range Programmable DC Power Supplies 9115 Series

IntesisBox KNX LG Air Conditioning

Agilent X/P/K281C Adapters

Experiment 7: Familiarization with the Network Analyzer

R&S ZNC Vector Network Analyzer Specifications

RClamp0821P. Ultra-Low Capacitance 1-Line ESD protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics

Power Meter Series 700

Engineering and service software For KNX and LPB plants

HYDRUS ULTRASONIC METER

Waveform Monitor Audio & Loudness Logging

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RF Measurements Using a Modular Digitizer

How To Use A Sound Card With A Subsonic Sound Card

Type-D EEG System for Regular EEG Clinic

NEW. EVEN MORE data acquisition and test stand automation

iva Cable & Antenna Analyzer

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Telephone- and leased line modem for industrial applications TD-36

Current Probes. User Manual

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

Accurate Measurement of the Mains Electricity Frequency

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Description: Multiparameter System (4 or 8 channels)

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Continuous, remote monitoring and logging of electromagnetic fields

PHASE SHIFT DUPLEXERS

Rack mounted telephone- and leased line modem for industrial applications

SolarMax P series The power package for residential solar plants

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

High Performance Schottky Rectifier, 3.0 A

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Switch Selection Guide

Surface Mount Schottky Barrier

DCS Series 1 kw, 1.2 kw, & 3 kw

JITAI Technology Co., LTD. Your 1 st Partner. Product Catalog. Microwave Passive Device Design and Manufacture

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Complimentary Reference Material

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Application Guide to RF Coaxial Connectors and Cables

DATA SHEET. TDA1510AQ 24 W BTL or 2 x 12 W stereo car radio power amplifier INTEGRATED CIRCUITS

Series 7500 Torque Sensor

IntesisBox KNX Modbus RTU master

Multi-Range Programmable DC Power Supplies 9115 Series

iva Cable & Antenna Analyzer

ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A8, October 27, 2012

Navi-Radar 4000 and Navi-Sailor 4000 ECS for workboats and small crafts BIG SOLUTIONS FOR SMALL VESSELS

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

Sound Power Measurement

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

10MQ100N SCHOTTKY RECTIFIER. I F(AV) = 2.1Amp V R = 100V. Bulletin PD rev. M 07/04. Major Ratings and Characteristics. Description/ Features

High Performance Schottky Rectifier, 1 A

1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Premium Server Client Software

US-Key New generation of High performances Ultrasonic device

Technical Data Sheet. 3DLevelScanner

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

1.44 kw Programmable DC Power Supplies XLN Series

Experiments Using the HP8714 RF Network Analyzer

Nardalert S3 Non-Ionizing Radiation Monitor

APPLICATION NOTES POWER DIVIDERS. Things to consider

Fractus Compact Reach Xtend

Physical Specifications (Custom design available.)

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

30BQ100PbF SCHOTTKY RECTIFIER. 3 Amp. I F(AV) = 3.0Amp V R = 100V. Bulletin PD rev. C 01/07. Major Ratings and Characteristics

Kit 27. 1W TDA7052 POWER AMPLIFIER

Keysight Technologies Understanding the Fundamental Principles of Vector Network Analysis. Application Note

Transcription:

HOMER Analyzer ISM 2.45 GHz, R-26 Waveguide Basic Description The HOMER-Series STH 2.45-GHz Analyzer is an automatic impedance and power measurement system based on R-26 (WR-340) waveguide. The system works under the full-power operating conditions of magnetron-based microwave generators and measures both magnitude and phase of reflection coefficient as well as incident, reflected and absorbed powers and frequency. The system is designed for CW, high-ripple (Rectified) and Pulsed sampling modes. STH can be: Used autonomously without external controller; Controlled from a personal computer or another controller via RS232 or CAN Bus interface; Integrated into a LabVIEW environment. The system comes with its own software (Server) and documentation. Principle of Operation The HOMER Analyzer is based on the six-port reflectometer (SPR) principle. SPR is capable of measuring complex reflection coefficient of the load as well as the incident, reflected and absorbed powers. A frequency counter is also integrated with the system. The conceptual simplicity of SPR facilitates its stable and temperature-independent operation over long periods of time. The system parameters required for the computations are obtained in the process of factory-made calibration where a collection of impedance standards is connected in place of load. It is recommended for the best performance that the recalibration be performed once a year. Reflectometers of this type are especially suitable for industrial applications where on-line monitoring and control under full working power is required. Modes of Sampling HOMER supports three modes of signal sampling, named CW, Rectified, and Pulsed. CW mode is applicable to unmodulated microwave signals with output power ripple not exceeding 15% of the peak value. Rectified mode is designed for slowly pulsing microwave signals (up to 400 Hz repetition rate). Such signals are typical for magnetrons powered by low-cost power supplies which incorporate simple half-wave or fullwave rectifiers. Pulsed mode (optional) is intended primarily for sampling fast square-pulse-modulated microwave signals with pulse widths down to 100 s. Rectified and Pulsed modes can provide both instantaneous and average values of reflection coefficient and power. Office: S-TEAM Lab, Budova FEI STU B212, Ilkovicova 3, SK-84104 Bratislava, Slovak Republic Tel./fax: +421-2-6542 7968 E-mail: support@s-team.sk http://www.s-team.sk

HomSoft Windows Control, Visualization and Data Logging Software The HomSoft control, visualization and data logging software significantly expands the system capabilities. The basic features include: Microsoft Windows environment Accurate measurement of complex reflection coefficient and its displaying in various formats, including - Magnitude - Phase - Return Loss - VSWR - Polar Display - Smith Charts (Z and Y) - Rieke-Type Chart Measurement of incident, reflected, and absorbed power and its displaying in various formats, including watts, decibels, percentage of incident power Numerical readout of signal frequency, load reflection coefficient and power in various formats Arbitrary shifting of the measurement plane Saving measured data as tables (text files) or pictures (BMP, GIF, JPG) Periodic data logging of all or some of the measured quantities Multiple windows enabling simultaneous observation of various quantities in different formats Wide selection of appearances of displayed curves Storing and retrieving of complete system settings tailored to particular tasks DDE server option enables another Windows application to share measurement results Extensive on-line help Example of HomSoft graphical user interface. Rev A9. Data subject to change. 2/6 29-Oct-2015

Specifications Electrical Waveguide type R-26 (WR-340) Flange type IEC Frequency range 2425 to 2475 MHz Maximum working power 1 2 30 kw Minimum working power 1 W Dynamic range of working power 20 db Reflection coefficient measurement error (uncertainty circle radius) 0.05 Incident power measurement error (matched load) 5 % Power supply voltage 24 V 10% DC Current consumption 0.7 A Interface RS232 or RS422, CAN Bus Modes of operation CW, Rectified, Pulsed Max ripple in CW mode 15 % of peak value Max repetition rate of signal envelope in Rectified mode 3 10 khz Min pulse width in Pulsed mode 100 s Mechanical Mass 3 kg Length 174 mm (6.85 in) Width 138 mm (5.43 in) Height 226 mm (8.90 in) Surface finish E-CLPS 4600 Environmental Operating temperature range +5 to +55 0 C Storage temperature range -10 to +125 0 C 1 2 3 Actual maximum working power is fixed according to customer s demand (must not exceed 30 kw). The actual minimum working power is 20 db (=dynamic range) below the actual maximum working power or 1 W, whichever is greater. In Rectified and Pulsed modes, maximum power means peak power (not its mean value). Signal envelope repetition rate (ripple frequency) f e is determined by power line frequency f p and rectification method. Examples: One-phase half-wave rectification f e =f p ; one-phase full-wave rectification f e =2f p ; three-phase half-wave rectification f e =3f p ; three-phase full-wave rectification f e =6f p ; three-phase Y+ half-wave rectification f e =6f p ; three-phase Y+ full-wave rectification f e =12f p. Rev A9. Data subject to change. 3/6 29-Oct-2015

Configurations Basic Configuration STH Basic Unit Internal firmware (Server) Calibration in 2425 to 2475 MHz band RS232 or RS422 serial interface CW and Rectified modes of operation Operating handbook (pdf) Communication protocol manual (pdf) Set of standard cables 4 Options 1. HomSoft Windows visualization and control software 2. Pulsed mode of sampling 3. CAN Bus communication interface (includes CAN Bus cable) 4. CAN-USB Adapter (to connect PC to CAN Bus network) 5. LabVIEW HOMER Virtual Instruments Library 6. Dynamic Data Exchange (DDE) server in HomSoft Windows SW 5 7. Technical support in hours (four hours are complimentary) Optional Power Supplies - Traco Power TBL 150-124, 24V/6.25A, DIN rail mountable - Electro-Automatik EA-PS-524-11T, 24V/10.5A, input 90-264 V, benchtop 4 5 Set of standard cables includes DC power supply cable, RS232/RS422 cable, and, in case of CAN Bus, CAN Bus cable. HomSoft Windows visualization and control SW option required. Rev A9. Data subject to change. 4/6 29-Oct-2015

Miscellaneous CAN-USB Adapter. To connect your PC with a CAN Bus network (or with the STHT alone), the Sontheim CAN USB Light Dongle adapter is needed. You can order it as an option. Another possibility is to buy the dongle yourself from the manufacturer (see http://www.s-i-e.de ). LabVIEW HOMER Virtual Instruments Library enables HOMER control and monitoring (measurement results retrieval) from within the National Instruments LabVIEW environment. The library consists of a number of virtual subinstruments and is accompanied by a few useful examples. The library enables users to integrate HOMER into their own applications with much less effort than trying to start from scratch by studying HOMER communication protocol and programming the communication themselves. DDE Server. DDE Server is a functionality within the HomSoft Windows SW hence it needs the HomSoft Windows visualization and control software option, too. The DDE Server enables another (customer s) Windows program to extract measurement results from HomSoft program, e.g. to a LabVIEW environment. Technical support. Very often users, especially in the initial phase, need counsel about issues that are not the matter of HOMER itself but of their particular application, or about topics that are in detail described in the accompanying documentation. Four hours of such support are provided free of charge; additional support should be ordered. Rev A9. Data subject to change. 5/6 29-Oct-2015

Basic Dimensions (in millimeters) Rev A9. Data subject to change. 6/6 29-Oct-2015