Electrodeposition of Nickel Particles and their Characterization



Similar documents
Laboratorio Regionale LiCryL CNR-INFM

Magnetic Media Measurements with a VSM

ZETA POTENTIAL ANALYSIS OF NANOPARTICLES

Materials Research for Advanced Data Storage

Usage of Carbon Nanotubes in Scanning Probe Microscopes as Probe. Keywords: Carbon Nanotube, Scanning Probe Microscope

T.M.M. TEKNIKER MICROMACHINING

New Approach to Analysis of the Switching Current Data in Ferroelectric Thin Films

Spin-flip excitation spectroscopy with STM excitation of allowed transition adds an inelastic contribution (group of Andreas Heinrich, IBM Almaden)

Sputtered AlN Thin Films on Si and Electrodes for MEMS Resonators: Relationship Between Surface Quality Microstructure and Film Properties

Magnetic Data Storage and Nanoparticles Ernie Chang

Study of the anomalous magnetic behavior of nanostructures by X-ray magnetic circular dichroism

Improved Contact Formation for Large Area Solar Cells Using the Alternative Seed Layer (ASL) Process

EXPERIMENTAL STUDY OF STRUCTURAL ZONE MODEL FOR COMPOSITE THIN FILMS IN MAGNETIC RECORDING MEDIA APPLICATION

Paper No APPLICATION OF EQCM TO THE STUDY OF CO2 CORROSION

Sn-Cu Intermetallic Grain Morphology Related to Sn Layer Thickness

Direct Observation of Magnetic Gradient in Co/Pd Pressure-Graded Media

Etudes in situ et ex situ de multicouches C/FePt

Pulsed laser deposition of organic materials

Basic principles and mechanisms of NSOM; Different scanning modes and systems of NSOM; General applications and advantages of NSOM.

Lecture 6 Scanning Tunneling Microscopy (STM) General components of STM; Tunneling current; Feedback system; Tip --- the probe.

Coating Thickness and Composition Analysis by Micro-EDXRF

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

- particle with kinetic energy E strikes a barrier with height U 0 > E and width L. - classically the particle cannot overcome the barrier

Neuere Entwicklungen zur Herstellung optischer Schichten durch reaktive. Wolfgang Hentsch, Dr. Reinhard Fendler. FHR Anlagenbau GmbH

Fabrication of Complex Circuit Using Electrochemical Micromachining on Printed Circuit Board (PCB)

FRAUNHOFER INSTITUTe For

Microscopie à force atomique: Le mode noncontact

XRaySwitchingStudyonThinFilmSiliconPhotovoltaicSolarPanel

CONCEPT OF DETERMINISTIC ION IMPLANTATION AT THE NANOSCALE

CHAPTER 5: MAGNETIC PROPERTIES

It has long been a goal to achieve higher spatial resolution in optical imaging and

MISCIBILITY AND INTERACTIONS IN CHITOSAN AND POLYACRYLAMIDE MIXTURES

Laserbearbeitung von dünnen Schichten auf Rolle-zu-Rolle-Anlagen

Permanent Magnet Materials

Implementation Of High-k/Metal Gates In High-Volume Manufacturing

Chapter Outline: Phase Transformations in Metals

Link, W. A., Individual heterogeneity and identifiability in capture recapture models. Animal Biodiversity and Conservation, 27.1:

, Yong-Min Kwon 1 ) , Ho-Young Son 1 ) , Jeong-Tak Moon 2 ) Byung-Wook Jeong 2 ) , Kyung-In Kang 2 )

Ultra-High Density Phase-Change Storage and Memory

X-Ray Study of Soft and Hard Magnetic Thin Films

h e l p s y o u C O N T R O L

DIEGO TONINI MORPHOLOGY OF NIOBIUM FILMS SPUTTERED AT DIFFERENT TARGET SUBSTRATE ANGLE

NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES

Spatially separated excitons in 2D and 1D

Observation of Long Transients in the Electrical Characterization of Thin Film BST Capacitors

Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser

NANOFLAM. Projet ANR Blanc 2011 BS Aide allouée: , durée 36+8 mois (fin : Mai 2015) Laboratoire H. Curien

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Novel inkjettable copper ink utilizing processing temperatures under 100 degrees C without the need of inert atmosphere

1. Photon Beam Damage and Charging at Solid Surfaces John H. Thomas III

Surface characterization of oxygen deficient SrTiO 3

KNOWLEDGE BASE ARTICLE Zero Voltage Transmission (ZVT) Technology. Basics of the GPZ 7000 Technology: Zero Voltage Transmission (ZVT)

Characterization of surfaces by AFM topographical, mechanical and chemical properties

PROBLEM-BASED LEARNING IN MATERIALS AND MANUFACTURING ENGINEERING EDUCATION ACCORDING TO THE ITESM-2015

OPTIMIZING OF THERMAL EVAPORATION PROCESS COMPARED TO MAGNETRON SPUTTERING FOR FABRICATION OF TITANIA QUANTUM DOTS

Atomic Force Microscopy. Long Phan Nanotechnology Summer Series May 15, 2013

Anharmonicity and Weak Mode Assignment in La 2 x Sr x CuO 4 with Oxygen Isotopic Substitution

Bi-directional FlipFET TM MOSFETs for Cell Phone Battery Protection Circuits

PHYSICAL PROPERTIES: GLASS. Forensic Science CC Spring 2007 Prof. Nehru

Characterization of excited states of 15 N through 14 C(p,p) 14 C using polarized proton beam

Determination of the Real Surface Area of Pt electro-catalyst by Hydrogen Under-potential (UPD) Deposition

NP Series VALVE REGULATED LEAD-ACID BATTERIES

Quantum Computing for Beginners: Building Qubits

Iron-Carbon Phase Diagram (a review) see Callister Chapter 9

Susana Sanduvete-Chaves, Salvador Chacón-Moscoso, Milagrosa Sánchez- Martín y José Antonio Pérez-Gil ( )

STM and AFM Tutorial. Katie Mitchell January 20, 2010

Exploring the deposition of oxides on silicon for photovoltaic cells by pulsed laser deposition

Atomic Force Microscopy Observation and Characterization of a CD Stamper, Lycopodium Spores, and Step-Height Standard Diffraction Grating

Exchange bias. J. Nogués, Ivan K. Schuller *

Capacitance and Ferroelectrics

Atomic Force Microscope and Magnetic Force Microscope Background Information

Effect of PWB Plating on the Microstructure and Reliability of SnAgCu Solder Joints

X-Rays and Magnetism From Fundamentals to Nanoscale Dynamics

Lab Report No.1 // Diodes: A Regulated DC Power Supply Omar X. Avelar Omar de la Mora Diego I. Romero

MAGNETIC PHASE AND DOMAIN EVOLUTION OF

Use of Carbon Nanoparticles for the Flexible Circuits Industry

SPM 150 Aarhus with KolibriSensor

CHANGES IN MAGNETIC DOMAIN STRUCTURE OF MARAGING STEEL STUDIED BY MAGNETIC FORCE MICROSCOPY

Piezoelectric Scanners

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

7/3/2014. Introduction to Atomic Force Microscope. Introduction to Scanning Force Microscope. Invention of Atomic Force Microscope (AFM)

Scanning Probe Microscopy

KOLEKTOR MAGNET TECHNOLOGY

Asset Sale: AFM System Veeco / DI DIMENSION 3100

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

Effect of the Hydrodynamic Conditions on the Electrochemical Degradation of Phenol on a BDD Anode

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

Investigation the Protective Performance of Organic Coatings with Different Breakage Degree Using EIS United to SOM Neural Network

Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft

Coating Technology: Evaporation Vs Sputtering

HANDBOOK OF MODERN FERROMAGNETIC MATERIALS

Transcription:

Article Electrodeposition of Nickel Particles and their Characterization Gerardo T. Martínez,* 1 Genaro Zavala, 2 and Marcelo Videa 3 J. Mex. Chem. Soc. 2009, 53(1), 7-11 2009, Sociedad Química de México ISSN 1870-249X 1 Laboratorio de Microscopía. Centro de Investigación en Química Aplicada. Blvd. Enrique Reyna # 140, Saltillo 25253, Coahuila, Mexico. gtadeo@ciqa.mx 2 Departamento de Física. Instituto Tecnológico y de Estudios Superiores de Monterrey, Campus Monterrey, Avenida Garza Sada 2501 Sur, Monterrey, N.L., 64849, México. (+52) 81 83 58 2000 ext 4631. genaro.zavala@itesm.mx 3 Departamento de Química. Instituto Tecnológico y de Estudios Superiores de Monterrey, Campus Monterrey, Av. Garza Sada 2501 Sur, Monterrey, N.L., 64849, México. (+52) 81 83 58 2000 ext 4513. mvidea@itesm.mx Received July 30, 2008; accepted February 17, 2009 Abstract. Electrodeposition of nickel on ITO substrates is achieved by current pulse reduction. A comparison between potential pulse and current pulse experiments presents differences in particle size and particle size distribution. The latter shows smaller particle size dispersion than what is found with potential pulses. Characterization of the carried out by Atomic Force Microscopy shows with average sizes between 100 to 300 nm. Magnetic characterization by Magnetic Force Microscopy and SQUID shows that of ~300 nm were ferromagnetic with a coercive field of 200 Oe and a saturation magnetization of 40 10-6 emu at 300 K. Key words: Electrodeposition, magnetic nano, Atomic Force Microscopy, Magnetic Force Microscopy. Introduction The development of methods that allow controlled growth of metallic has gained special interest due to novel applications in electrocatalysis, data storage, and the construction of devices at nanotechnology. These applications demand a controlled production of with specific dimensions and low size dispersion, through procedures that make it feasible to bring them into industrial application. Electrodeposition of metallic through a double potential pulse technique has been studied extensively [1]. The potentionstatic doublepulse procedure, characterized by the pulses E 1 and E 2 and their corresponding pulse durations t 1 and t 2, is an efficient way to control the particle size distributions of electrodeposits. It is based on the knowledge of the critical potential for the system, E crit, which is the minimal potential that has to be applied in order to allow the formation of nuclei. The first pulse, which should be more negative than E crit, is used to initiate the formation of the nuclei and the second pulse, less negative than E crit but more negative than the reversible potential, is used to control the growth of the nuclei formed during the previous pulse [2]. To achieve particle growth, the overpotential of the second pulse must be low enough to inhibit generation of new nuclei. Under such circumstances, the original distribution of stable nuclei formed during the first pulse should be preserved [3]. The mechanism of nucleation and growth has also been studied and it is concluded that depending on the potential of the applied pulse, the nucleation can be either instantaneous or progressive [4-7]. Resumen. Se realizó la electrodeposición de partículas de níquel sobre substratos de ITO mediante la aplicación de pulsos de corriente. La comparación entre el método de pulsos de potencial y pulsos de corriente muestra diferencias en el tamaño de partícula y su distribución. El método de pulsos de corriente conduce a una menor dispersión en el tamaño de partícula que el observado con pulsos de potencial. La caracterización de las partículas se llevó a cabo por Microscopía de Fuerza Atómica mostrando partículas con un tamaños promedio entre 100 y 300 nm. Mediante Microscopía de Fuerza Magnética y SQUID se determinó que partículas de ~300 nm son ferromagnéticas, con un campo coercitivo de 200 Oe y una magnetización de saturación de 40 10-6 emu a 300 K. Palabras clave: Electrodeposión, partículas magnéticas, Microscopía de Fuerza Atómica, Microscopía de Fuerza Magnética. This work explores the use of one current pulse, which forces the electrode s potential during electrodeposition to adjust to the imposed kinetics for electron transfer. The results obtained on the preparation of nickel through a current pulse method to study their magnetic properties in order to develop suitable materials for the magnetic information storage industry are reported. Topographical and magnetic characterization of the electrodeposited is presented. Pulse duration effect on the particle size distribution is discussed. Experimental Setup The electrodeposition experiments were carried out in a threeelectrode arrangement. Since the magnetic properties of the deposits were to be characterized, thin films of Indium Tin Oxide (ITO) on glass were selected as working electrodes (WE) to avoid magnetic interactions of the with the substrate. Each experiment was strictly performed on fresh ITO electrodes. A Pt wire as counter electrode (CE), and a Ag/ AgCl electrode (RE) as reference electrode. A 0.05M Ni 2 SO 4 with 0.1M NaSO 4 solution was used. The pulses were applied using an EG&G Princeton Applied Research potentiostat/galvanostat. Equal intensity pulsed current experiments of 0.5 ma with different durations, 90 ms, 110 ms, 500 ms, 1000 ms, 5000 ms, 10,000 ms and 15,000 ms, were performed. Since a current pulse induces a response in which the working electrode polarizes until it reaches a minimum and

J. Mex. Chem. Soc. 2009, 53(1) Gerardo T. Martínez et al. then stabilizes to a fixed value, equivalent values for E 1 and E 2 can be determined from the experimental polarization curves (see Fig. 1) and then be used for a double potential experiment to compare results from both techniques. The lowest value for the potential reached when a pulse of 0.5 ma of current is applied was 960 mv and this value was chosen as the nucleation pulse (E 1 ). The value of stabilization of potential, 850 mv, was chosen as the growth pulse (E 2 ). Using these parameters, a double potential pulse was set up in order to compare the results obtained with these two different techniques. After the electrodeposition experiments, samples were topographically characterized using a Veeco Nanoscope IIIa Multimode Atomic Force Microscope with Veeco MESP silicon tips in tapping mode. The images were analyzed using a Matlab routine for image processing [8]. For the magnetic characterization, the same equipment was used in Magnetic Force Microscopy (MFM) mode to obtain the magnetic domain images, and a Superconducting Quantum Interference Device (SQUID) for the magnetization curves. The MFM images were taken with a lift scan height of 300 nm and the sample was previously magnetized in longitudinal direction. Results The results obtained by the pulsed current experiments are presented in figure 1, where the behavior of the potential is shown when a 0.5 ma pulse is applied to the system. It can be observed that the polarization of the electrode is similar to a two-potential pulse experiment since after the current pulse there is a sharp drop in the electrode potential followed by a recovery to a higher and constant potential. In Figure 1, the time axis is plotted logarithmic scale to allow the inspection of the current curve at the shortest times. During the first 50 ms of the current pulse the potential drops to a minimum near 960 mv which later recovers, reaching a constant value. The first stage will be called a varying step and the second stage will be called stabilization step of the potential. These stages are related to the nucleation and growth of the on the substrate. Table 1 shows the statistical information of the single current pulse experiments. It is observed that the density of increases at very short pulse lengths and then it stabilizes at longer times. The mean particle size does not vary greatly at the early stages of the experiment (90-110 ms) but then there is a small decrease of size (500-5000 ms) which will be followed by an increase of particle size at longer durations (10,000-15,000 ms). The standard deviation of the particle size maintains a regular value for the different pulse lengths and it increases on longer time experiments. Figure 2 shows AFM images where it can be observed the size and distribution of the. 15 mm 15 mm scans were performed to get an overall view of the distribution and a 3 mm 3 mm scan to observe the in more detail. Fig. 1. Potential behavior after a 0.5 ma pulse is applied to the system. The plot shows several experiments superimposed in which the pulse length is varied from 90 ms to 15,000 ms. Table 1. Statistical information of the pulsed current experiments. The data is obtained after the analysis of the AFM images. Duration of current pulse Density of Mean equivalent Standard Deviation of equivalent 90 ms 0.83 / mm 2 162 nm 53 nm 110 ms 1.94 / mm 2 167 nm 43 nm 500 ms 2.01/ mm 2 147 nm 53 nm 1000 ms 1.85 / mm 2 137 nm 43 nm 5000 ms 1.05 / mm 2 132 nm 57 nm 10,000 ms 1.56 / mm 2 225 nm 64 nm 15,000 ms 1.53 / mm 2 246 nm 95 nm In the double potential pulse technique, similar potential values as the ones obtained in the pulsed current experiments were used. The same potential pulse E 1 to nucleate the was used and the duration of the growth pulse E 2 was varied. Figure 3 shows the current behavior during the potential pulses. It can be observed that during the first pulse it was obtained the typical nucleation curve [4] for electrodeposition and an increase of the current, indicating a possible growth of the. The first potential pulse has the same duration as the first current pulse applied, which was 90 ms. In the second potential pulse, the current is nearly stable on 0.5 ma, indicating a growth of the at constant speed. Table 2 presents the statistical information of the double pulsed potential experiments. The duration of the experiments is very short compared to the duration of the pulsed current experiments. However,

Electrodeposition of Nickel Particles and their Characterization 9 Table 2. Statistical information of double pulsed potential experiments. The data was obtained after the analysis of the AFM images. Duration of first potential pulse Duration of second potential pulse Density of Mean equivalent Standard Deviation of equivalent 90 ms 90 ms 0.43 / mm 2 205 nm 82 nm 90 ms 180 ms 0.31 / mm 2 232 nm 77 nm 90 ms 270 ms 0.31 / mm 2 332 nm 117 nm Fig. 2. AFM images show the evolution of the particle deposition growth and the increase in particle density as pulse time increases. Figure 4 shows the AFM images obtained in the double pulsed potential experiments. It can be observed that the growth of the is very fast at short times compared to the pulsed current experiments. The standard deviation of the particle size also increases with time resulting in a wide particle size distribution. Particles of ca. 300 nm were characterized by Magnetic Force Microscopy and their magnetic properties were obtained by SQUID. These showed to be ferromagnetic at room temperature (300 K) with a magnetization of 40 10-6 emu. Figure 5 shows their magnetization hysteresis and Figure 6 shows the MFM images along with topography. Fig. 3. Current response after applying two potential pulses. The first pulse of -960 mv for 90 ms shows the nucleation stage and some growth process, while the second pulse of -850 mv was applied for 90, 180 and 270 ms to observe the growth mechanism. the mean particle size and its standard deviation are greater. The density of is almost constant. These results are expected by using this technique because the first potential pulse allows the formation of a determined number of nuclei, and the second potential pulse makes them grow. Fig. 4. AFM images show the fast growth of the at short times. The density of remains very similar at all times.

10 J. Mex. Chem. Soc. 2009, 53(1) Gerardo T. Martínez et al. Fig. 5. Magnetization curve of ~300 nm obtained by SQUID. They show ferromagnetic behavior. Discussion It is shown that with the pulsed current method the growth of can be achieved more efficiently than that obtained with the double pulse method. The behavior of the cell potential indicates two steps, a nucleation process at the start and a growth process when it stabilizes. The change in the cell potential induced by the current pulse indicates that at short times (< 100 ms) a progressive deposit of is achieved. At longer times the growth of the larger is limited by diffusion due to a depletion layer [9] established around the. Meanwhile, in the regions of the substrate that are free of deposit smaller grow. This can be seen in Figure 7, where the particle size distribution plots are shown. The average particle size shifts to larger values keeping the size dispersion almost unchanged. This is interpreted as that the varying part of the pulse promotes nucleation and growth of ; however, since the system is forced to a determined speed of electron transfer, the system favors different processes at different sites of the substrate. At the beginning several nuclei are formed and these grow until a certain size is reached which is limited by diffusion, due to the depletion of nickel ions around them. At this point, other nuclei are formed (progressive nucleation), keeping up with the imposed rate of charge transferred. The stabilization will be reached when all nuclei reach the size in which their growth is limited by diffusion. At this stage, the growth of is constant to maintain the speed of the process. This results in a low dispersion of particle size. The double pulse method produces lower density of, although the growth of the is faster. The nucleation seems to be instantaneous in this case, so, there is not an increase in the number of. The magnetic characterization of the show that they are in fact magnetic with a well defined hysteresis shown in Figure 5. The have a remnant magnetization of 40 10-6 emu and a coercive field of 200 Oe which make them soft magnetic material with a small remnant magnetization compared with what is obtained with bulk Nickel. Since SQUID measures a collective magnetization contribution, MFM images were obtained trying to see the behavior of a single particle. The images presented in Figure 6 show that after magnetizing the sample, the magnetic moments of the are aligned to give a longitudinal magnetization monodomain image with changes of magnetic signal at the edges and uniform signal above the [10]. Conclusion An alternative electrodeposition current pulse method is proposed to achieve magnetic Ni. The particle size and particle size distribution depend on the duration of the current Fig. 6. AFM topography and MFM image of ~300 nm. Fig. 7. Image shows the particle distributions of the pulsed current experiments. We observe that at short times, there is an increase on number of and at longer times, there is an increase in the size of the, leaving the particle size dispersion almost unchanged.

Electrodeposition of Nickel Particles and their Characterization 11 pulse. An increase on particle density is observed during the varying step of the current pulse and a growth of the during the stabilization step of the current pulse. This method allows experiments of longer time periods than the traditional pulsed potential method, which can be taken as an advantage for variable control and sampling accuracy of the equipment. The SQUID measurements show that the of ~300 nm were ferromagnetic with a coercive field of 200 Oe and a saturation magnetization of 40 10-6 emu at 300 K, while MFM images showed that the are single domain. Acknowledgements We thank the CAT-007 and CAT-120 Research Programs by the Tecnológico de Monterrey and CONACyT for the financial support of this research. Special thanks to Alex de Lozanne and Changbae Hyun at the Physics Department of the University of Texas at Austin for their discussions and equipment support in the SQUID measurements. References 1. Budevski, E.; Staikov, G.; Lorenz, W. J. Electrochim. Acta. 2000, 45, 2559-2574. 2. Sandmann, G.; Dietz, H.; Plieth, W. J. Electroanal. Chem. 2000, 491, 78-86. 3. Ueda, M.; Dietz, H.; Anders, A.; Kneppe, H.; Meixner, A.; Plieth, W. Electrochim. Acta 2002, 48, 377-386. 4. Sharifker, B.; Hills, G. Electrochim. Acta 1983, 28, 879-889. 5. Sharifker, B.; Mostany, J. J. Electroanal. Chem. 1984, 177, 13-23. 6. Sluyters-Rehbach, M.; Wijenberg, J. H. O. J.; Bosco, E.; Sluyters, J. H. Electroanal. Chem. 1987, 236, 1-20. 7. Heerman, L.; Tarallo, A. J. Electroanal. Chem. 1999, 470, 70-76. 8. http://www.nacs.uci.edu/dcslib/matlab/matlab-v60/help/toolbox/ images/gettings.html, accessed August 2006. 9. Penner, R. M. J. Phys. Chem. B 2001, 105, 8672-8678. 10. Rugar, D.; Mamin, H. J.; Guethner, P.; Lambert, S, E.; Stern, J. E.; McFayden, I.; Yogi, T. J. Appl. Phys. 1990, 68, 1169-1183.