Firmware upgrade instructions for the Web/SNMP and Network



Similar documents
Network Management Card Wizard--1. Introduction... 1 Using the Network Management Card Wizard... 5

Title Page Web/SNMP Management SmartSlot Card

Network Management Card

How to Log On Main Screen Control Console Menus How to Log On Summary Page Navigation Menu... 29

Network Management Card. Installation and Quick Start Manual

USER S GUIDE Switched Rack PDU

USER S GUIDE. network management card. Contents. Introduction--1. Control Console--13

Updating MNS-BB CUSTOMER SUPPORT INFORMATION PK012906

USER S GUIDE. network management card. Contents. Introduction--1. Control Console--13

1. Installing and configuring APC UPS Management

Environmental Monitoring Unit

File Transfers. Contents

Device Installer User Guide

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

MasterSwitch Power Distribution Unit

Quick Note 038. Upgrade Software options and/or VPN Licenses on a Digi Transport router.

Connecting the DG-102S VoIP Gateway to your network

Update Firmware from GUI

1 MAXDATA Modular System Firmware Update

Liebert IntelliSlot Web Cards

Debugging Network Communications. 1 Check the Network Cabling

[HOW TO RECOVER AN INFINITI/EVOLUTION MODEM IDX ] 1

File Transfers. Contents

Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7

Network Management Card

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

SMC7004ABR Barricade Broadband Router Installation Instructions

FRM301 SNMP Upgrade Procedure

User s Guide. Network Management Card AP9631-IBM

Moxa Device Manager 2.0 User s Guide

How To Log On Main Screen Control Console Menus... 19

Chapter 4 Management. Viewing the Activity Log

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

SNMP-1 Configuration Guide

Configuring the Switch with the CLI Setup Program

Using Internet or Windows Explorer to Upload Your Site

Alarm Messages Clearing the Hardware Alarms How to Log On Summary Page Navigation Menu... 24

How to Upgrade the Firmware of a Brother Printer/Print Server

HP Security Modules. Software Upgrade Guide. Part number: Document version: 6PW

Configuring the CyberData VoIP 4-Port Zone Controller with Audio Out

Using IDENT M System T with Modbus/TCP

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Binary Upgrade Procedure

Chapter 3 Management. Remote Management

VoIP Ceiling Speaker with Allworx 6x Server Setup Guide

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

User Guide. Switched With Metering-by-Outlet Rack Power Distribution Unit AP8641, AP8653, AP8661

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

VoIP Intercom with Allworx 6x Server Setup Guide

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

Environmental Management System

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

Unified Access Point Administrator's Guide

3.5 EXTERNAL NETWORK HDD. User s Manual

USER S GUIDE. Contents. NetBotz Rack Monitor 200. Introduction--1. Control Console--8

QNAP SYSTEMS INC. QNAP Digital Signage Player Web Console Manual

Connecting and Setting Up Your Laptop Computer

User s Guide. Metered Rack Power Distribution Unit

IP Phone Configuration and Troubleshooting Guide

FirePass NSE RMA4 Replacement Script. FirePass. Network Support Engineer RMA4 Replacement Script, Version 1.01

User s Manual Network Management Card

AT-S99 and AT-S102 Version Management Software for the Converteon Media Converter Products. Software Release Notes

Network Load Balancing

c. Securely insert the Ethernet cable from your cable or DSL modem into the Internet port (B) on the WGT634U. Broadband modem

Maintaining the Content Server

D-Link Central WiFiManager Configuration Guide

User s Guide. Managed Rack Power Distribution Unit

Technote 20 Using MSIE to FTP into an AcquiSuite

Network Management Card. User Manual

Do not start HiQnet London Architect on the computer until instructed to do so below at Start and Configure HiQnet London Architect.

Honeywell Internet Connection Module

Focal Point 2.1 Management Software & CPSMM100 Firmware Manual

Starting a Management Session

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

Chapter 6 Using Network Monitoring Tools

LevelOne VOI H.323 VoIP Gatekeeper. User Manual

IIS, FTP Server and Windows

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I Rev B

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

Virtual Appliance Setup Guide

User s Guide. Network Management Card AP9635

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

How to convert a wireless router to be a wireless. access point

Network Monitoring User Guide Pulse Appliance

SNMP Manager User s Manual

IP SERIAL DEVICE SERVER

Sky Broadband upgrading your router software

Software Installation Guide

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

MasterSwitch. Power Distribution Unit. User s Guide AP9211 AP9212

HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide

CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs

ACP ThinManager Tech Notes Troubleshooting Guide

User Manual. Thermo Scientific Orion

L Firmware And FPGA Configuration Upgrade

GV-Data Capture V3 Series User's Manual

Securely manage data center and network equipment from anywhere in the world.

Transcription:

Page 1 of 6 Answer ID 768 Firmware upgrade instructions for the Web/SNMP and Network Management Cards Question How do I upgrade the firmware on an APC Web/SNMP Management Card or Network Management Card? Answer Solution: When upgrading the firmware on your Web SNMP/Network Management Card, you need to determine which files pertain to your application. First, look on your card. If the part number is AP9606, then you have a Web SNMP Management Card. If the part number is AP9617/AP9618/AP9619, then you have a Network Management Card. **If the part number is Powernet SNMP adapter, AP9605, or AP9603, there are no firmware updates available.** Second, you need to determine which device you have the Web SNMP/Network Management installed in. For example, if you have the Network Management Card installed in a UPS, you need to determine which UPS you have. APC offers four different UPS families. These four families are as follows: SmartUps/Matrix Symmetra (Symmetra, Symmetra Rackmount, Symmetra LX) Symmetra 3 phase (Symmetra PX) Silcon Select the correct UPS type. Next, go to the Network Management Card section on the software downloads page. A link to the software downloads page is below: http://www.apcc.com/tools/download/ If you have a Smart Ups 700, then you will choose: Network Management Card x.x.x firmware executable for Smart Ups and Matrix w/ap9617/8/9 installed Click on the Free Download link on the left hand side of the page. Proceed through the menus and download the firmware executable. Once you have the firmware downloaded, then you can proceed with the upgrade. There are a couple of different ways that you can upload the firmware.

Page 2 of 6 - Firmware executable - Xmodem - Manual (FTP prompt) Firmware executable If you have a Windows NT/2000 computer, you can use the executable to upgrade the firmware. If you have any other type of computer, then you will need to manually upload each firmware file to the Web SNMP/Network Management Card. Go to the Xmodem or Manual section for firmware upgrades. Click on the firmware executable once the download is complete. The executable will proceed to unzip firmware files. You can specify the location where you want the firmware to download to. Once the firmware has been saved, the executable will prompt you for the IP address of the Web SNMP/Network Management Card that you want to upgfade. Once you enter the IP address, click enter. You will be prompted for a username and password. Use the username/password that you normally use to log into the card. By default, the username and password is apc. Press enter. You will then be prompted to either 1) Continue with upgrade 2) Re-enter Parameters 3) Quit. Choose option 1 then enter. The firmware executable will then begin the upgrade process. This process may take as long as 5-7 minutes to finish. Once finished, close the executable. Verify that the firmware upgrade was successful. Log into the card and go to Help, then About System. The updated firmware should be listed on this page. Xmodem ***For AP9617/18/19 cards that have AOS 1.2.0 firmware and below, you will need to first upgrade to AOS 2.0.2 before upgrading to the latest firmware. AOS 2.0.2 should be included as part of the firmware executable located on the firmware download page.*** 1. Connect the Management Card to an available serial port on the host computer with the supplied cable (part number 940-0024C). 2. If PowerChute is running then stop that service. 3. Open a terminal session. Configure the terminal session to 2400bps, no

Page 3 of 6 parity, 8 data bits, 1 stop bit, and no flow control. If you are using HyperTerminal select Call->Disconnect and then Call->Connect to apply the changes to the serial port. 4. Press the <Enter> key several times. You should see a User Name prompt. If you do not see the prompt, make sure that you have the proper cable and that the communication settings are correct. 5. Log into the Management Card. 6. Enter the Administrator User Name and Password. The default for both is "apc". If you have changed the Administrator User Name and Password, use the new settings to log in. The main Control Console menu will appear. 7. Start an XMODEM transfer. 8. Select option 3 - System. 9. Select option 4 - File Transfer. 10. Select option 2 - XMODEM. 11. Enter "YES" at the prompt to continue with the transfer. 12. Select the appropriate baud rate. The higher the baud rate, the faster the firmware upgrade. 13. Change the terminal program's baud rate to match the one you selected in step 4. If you are using HyperTerminal select Call->Disconnect and then Call->Connect to apply changes made to the serial port. Press <ENTER> to continue. 14. From the terminal program's menu, select the binary platform file (the file with the plat prefix) to transfer via XMODEM-CRC. 15. After the XMODEM transfer is complete set the baud rate back to 2400. The

Page 4 of 6 Management Card will automatically reboot itself. (Please note that a reboot of the control unit does not reboot outlets) Manual (via FTP) ***For AP9617/18/19 cards that have AOS 1.2.0 firmware and below, you will need to first upgrade to AOS 2.0.2 before upgrading to the latest firmware. AOS 2.0.2 should be included as part of the firmware executable located on the firmware download page.*** 1. To perform an upgrade with this method the Management Card must have been previously configured with a System IP, Subnet Mask, and Default Gateway and attached to the network. In addition, FTP Server must be enabled. 2. Open an MS-DOS command prompt window on a PC which is connected to the network. Change to the directory which contains the firmware upgrade files. The commands which need to be entered are shown in bold. C:\>cd\apc C:\apc> 3. Open an FTP client session. C:\apc> ftp 150.250.6.21 (150.250.6.21 being the IP address of the web card) 4. Log in using the Administrator User Name and Password. Your passwords may be different than the defaults, "apc" and "apc". Typically, the password will appear on the screen as ***. Connected to 150.250.6.21

Page 5 of 6 220- APC FTP server ready. 220 User (150.250.6.10:(none)):apc 331 User name okay, need password. Password:apc 230 User logged in, proceed. ftp> 5. Upgrade the aos first. The aos module is the file with the aos prefix. ftp> bin 200 Command okay. ftp> ftp> put aosxxx.bin (XXX being the version number downloaded) 200 Command okay. 150 Opening data connection for aos301.bin 250 Requested file action okay, completed. Management Card Rebooting... 327680 bytes sent in 5.99 seconds (54.70 Kbytes/sec) ftp> 6. Close the FTP client session. ftp>bye C:\apc> 7. Wait about 20-30 seconds. 8. Repeat Steps 3-8 again for the application module (sumx for Smart Ups/Matrix, sy for Symmetra, etc). In Step 6, substitute the

Page 6 of 6 sumx module file name, in place of the aos module file name. Or the sy prefix for the Symmetra Note : Never remove the Management Card before it completes the reboot cycle. Doing so will damage the Management Card. The reboot cycle is complete when the status LED turns off and after 20 seconds turns solid green or slowly flashing red.