MasterSwitch. Power Distribution Unit. User s Guide AP9211 AP9212
|
|
|
- August Wright
- 9 years ago
- Views:
Transcription
1 MasterSwitch Power Distribution Unit AP9211 AP9212 User s Guide
2 Thank You! Thank you for selecting the APC MasterSwitch power distribution unit. It has been designed for many years of reliable, maintenance-free service. APC is dedicated to the development of high-performance electrical power conversion and control products. We hope that you will find this product a valuable, convenient addition to your computing system. Please read this manual! It provides important configuration and operating instructions that will help you get the most from your MasterSwitch unit. For safety information and instructions on the installation and initial configuration of the MasterSwitch unit, see the Installation and Quick Start Manual provided in printed form with the unit and in PDF format (Install.pdf) on the MasterSwitch CD-ROM. Save this manual! It includes instructions for obtaining warranty service. MasterSwitch Power Distribution Unit User s Guide ii
3 Contents MasterSwitch Power Distribution Unit Introduction Product Description Front panel 1 LEDs 2 Rear panel 3 Initial Setup Configuring TCP/IP settings 4 Customizing your configuration 4 Auto-configuration 4 Managing the MasterSwitch PDU Management Interfaces Management Options 5 Web interface 5 Control Console interface 6 Password-Protected Accounts Account access 8 Menu Items Introduction Management Options 9 Outlets MasterSwitch Outlet Configuration 11 Event Log Retrieving the Event Log by using FTP 12 Using a spreadsheet to view the Event Log 13 Deleting the Event Log in the FTP interface 13 Network TFTP/FTP 14 Telnet/Web 15 SNMP 15 System Outlet User Management 19 Identification 20 Date/Time 20 File Transfer 21 MasterSwitch Power Distribution Unit User s Guide iii
4 Contents Links 22 Help Accessing and Navigating the Online Help 23 APC Interactive Assistant 23 About Card 23 Security Security Features Planning and implementing security features 24 Port assignments 24 User names, passwords, community names 24 Authentication Authentication versus encryption 25 MD5 authentication (Web interface) 25 Summary of access methods 27 Product Information Warranty Information Obtaining service 28 Warranty exclusions 28 Obtaining Customer Support Contacting Customer Support 29 Life-Support Policy General policy 30 Examples of life-support devices 30 Specifications Product specifications for AP Approvals for AP Product specifications for AP Approvals for AP Index APC Worldwide Customer Support MasterSwitch Power Distribution Unit User s Guide iv
5 Introduction Product Description MasterSwitch Power Distribution Unit Front panel.! Reset Button Re-initializes the MasterSwitch PDU without affecting the outlet state. " Status LED Indicates the status of the Ethernet LAN connection and the state of the management card, as described in LEDs # Link-RX/TX LED on page 2. $ Eight Outlet Power LEDs Indicates whether the associated outlet is on. % Serial Port Connects the MasterSwitch PDU to a terminal emulator program to access the Control Console. & RJ-45 Port Connects the MasterSwitch PDU to an Ethernet LAN using the 10Base-T communication cable. This connection allows configuration of the MasterSwitch PDU through the Web, Telnet, or SNMP. Continued on next page MasterSwitch Power Distribution Unit User s Guide 1
6 Introduction Product Description continued LEDs Each outlet has a corresponding LED that indicates the state of the outlet, and two LEDs indicate the status of the entire unit. The following table describes the conditions indicated by the LEDs. LED Status Description Outlet LED Status Link-RX/TX On Off Off Green Flashing Green Red Blinking Red Off Flashing Green The Outlet is on. The Outlet is off. The MasterSwitch PDU has no power. The MasterSwitch PDU has valid network settings. The MasterSwitch PDU does not have valid network settings. A hardware failure has been detected in the MasterSwitch PDU. The MasterSwitch PDU is making BOOTP requests. The device that connects the MasterSwitch PDU to the network (a router, hub, or concentrator) is off or is not operating correctly. The MasterSwitch PDU is receiving data packets from the network. Continued on next page MasterSwitch Power Distribution Unit User s Guide 2
7 Introduction Product Description continued Rear panel The following table lists the features of the MasterSwitch rear panel shown in the figures on this page.! Power Cord/ IEC Inlet " Outlets # Outlet Label $ Circuit Breaker The following figure shows the MasterSwitch (AP9211) rear panel with NEMA 5-15 outlets. The following figure shows the MasterSwitch (AP9212) rear panel with IEC-320 C13 outlets. MasterSwitch Power Distribution Unit User s Guide 3
8 Introduction Initial Setup Required network settings You must configure the following network settings of the MasterSwitch PDU before it can operate on a network: IP address of the unit Subnet Mask IP address of the default gateway Note: If a default gateway is not present, enter an IP address of a computer that is on the same subnet and that is always active. Configuring TCP/IP settings To configure TCP/IP settings, see TCP/IP on page 14 and see the MasterSwitch Installation and Quick Start Manual, included in printed form with the MasterSwitch PDU and in Portable Document Format (Install.pdf) on this CD-ROM. Customizing your configuration After you configure MasterSwitch network settings, no further configuration is required. The remaining MasterSwitch properties are pre-configured to default settings at the factory. However, you may want to customize these properties for your application. For more information, see Managing the MasterSwitch PDU on page 5. Auto-configuration The management card within the MasterSwitch PDU supports an autoconfiguration utility that you can use to create a configuration file, which you can then download to other MasterSwitch PDUs, either to individual units one at a time or to multiple units at the same time. For more information, see the Management Card Addendum (addendum.pdf on the MasterSwitch CD-ROM). MasterSwitch Power Distribution Unit User s Guide 4
9 MasterSwitch Power Distribution Unit Managing the MasterSwitch PDU Management Interfaces Management Options After you configure a MasterSwitch PDU with the proper network settings, you can manage the unit remotely through its Web, Control Console, and SNMP interfaces. You can also use the Control Console to manage a MasterSwitch PDU locally through a serial connection. Only one user at a time can access a MasterSwitch PDU. Serial interface users (using a terminal emulator) have precedence over Telnet users, and Telnet users have precedence over Web users. Web interface To access and log on to the Web interface of the MasterSwitch PDU: 1. In the URL Location field of the Web browser, do one of the following: If the Web port of the MasterSwitch PDU is set to the default value of 80, enter followed by the unit s IP address. The following example shows a typical IP address: If the Web port of the MasterSwitch PDU is set to a value other than the default of 80, enter the System IP address (the IP address of the unit) followed by a colon and the configured Web port value (8000 in the following example). If there is a DNS server entry for the MasterSwitch PDU, you can choose to enter the DNS name to access the unit. Continued on next page MasterSwitch Power Distribution Unit User s Guide 5
10 Managing the MasterSwitch PDU Management Interfaces continued Web interface, continued 2. Respond to the user name and password prompts. The default for both the Administrator user name and the Administrator password is apc (lowercase). After you log on, you can change the user name, password, and time-out values through the System menu. See User Manager on page 17. Note: Some Web interface features (data verification, Assistant Online, and MD5 authentication) require that you enable JavaScript or Java on your web browser, and MD5 authentication also requires that you have cookies enabled. Control Console interface In addition to or instead of using the Web interface, you can use the Control Console to manage the MasterSwitch PDU by one of the following modes of access: Telnet, for remote management. A serial interface, for local management. Telnet. To access the unit s Control Console using a serial connection: 1. Choose Connect, then Remote Server. 2. Type the IP address of the MasterSwitch PDU. 3. Click the Connect button. Continued on next page MasterSwitch Power Distribution Unit User s Guide 6
11 Managing the MasterSwitch PDU Management Interfaces continued Control Console interface, continued Serial Interface. To access the unit s Control Console, use the supplied null-modem cable ( ) to connect the serial port of the computer to the serial port on the MasterSwitch PDU, and set the terminal port to the following communication settings: Baud Rate 2400 Data Bits 8 Stop Bits 1 Parity Handshaking Local Echo Terminal Type None None Off ANSI (VT100) Logging on. To log on to the Control Console using either Telnet or a serial interface, respond to the user name and password prompts.the default for both the Administrator user name and the Administrator password is apc (lowercase). Note: You can change the user name, password, and time-out values through the System menu. See User Manager on page 17. Using menu items. All menus of the Control Console list items by number and name. To select an item, type the number, and press ENTER. For menus that configure value, always use the Accept Changes option to save any changes that you make. MasterSwitch Power Distribution Unit User s Guide 7
12 Managing the MasterSwitch PDU Password-Protected Accounts Account access There are up to 16 Outlet User accounts, one Administrator account, and one Device Manager account. Each type of account provides a different level of access to the management menus. Each Outlet User account has access only to the outlets assigned to it. The Administrator and Device Manager accounts have access to all outlets. The Administrator account can configure and manage all other accounts. Menu Items Administrator Account Type Device Manager Outlet User Outlets Yes Yes Yes MasterSwitch Yes Yes No Event Log Yes Yes No Network Yes No No System Yes No No Logout Yes Yes Yes Help Yes Yes Yes Links Yes Yes Yes For instructions on configuring Device Manager and Outlet User accounts, see User Manager on page 17. MasterSwitch Power Distribution Unit User s Guide 8
13 Menu Items Introduction MasterSwitch Power Distribution Unit Management Options Both the Web and Control Console interfaces provide the capabilities that this section describes for managing the MasterSwitch PDU, but the information in this section is based on the Web interface. If you are using Telnet or a serial interface to access the MasterSwitch PDU, terminology may differ from what is used here. Menu access depends on which type of account has logged on. See Password-Protected Accounts on page 8 for more information on accounts. Note: SNMP information appears in a separate document, Mibguide.pdf, on this CD-ROM. MasterSwitch Power Distribution Unit User s Guide 9
14 Menu Items Outlets Outlet Control Actions You can perform the following Outlet Control Actions on individual outlets or on all accessible outlets as a group (by Master Outlet Control). You can apply a Control Action only to an outlet that is not executing a command. Item Definition Immediate On Immediate Off Immediate Reboot Delayed On Delayed Off Sequenced Reboot Delayed Reboot Delayed Sequenced Reboot Cancel Pending Commands The outlet turns on. The outlet turns off. The outlet turns off immediately, waits the outlet s Reboot Duration time, and turns on. The outlet turns on according to its Power On Delay. The outlet turns off according to its Power Off Delay. All outlets in the group assigned to the outlet user immediately turn off. Each outlet then waits the longest Reboot Duration (in seconds) of any outlet in the group, waits its own Power On Delay, and turns on. The outlet turns off after its Power Off Delay, waits its own Reboot Duration, and turns on. Each outlet in the group of accessible outlets does the following: 1. Waits its own Power Off Delay. 2. Turns off. 3. Waits the longest Reboot Duration time (in seconds) of any outlet in the group. 4. Waits its own Power On Delay. 5. Turns on. All pending commands are canceled for the outlet(s). Note: The Outlet State appears in orange with an asterisk (*), indicating that a command is pending for the outlet(s). MasterSwitch Power Distribution Unit User s Guide 10
15 Menu Items MasterSwitch Configure Device Settings Item Unit Name Coldstart Delay Reboot Duration Definition The name of the MasterSwitch PDU. Maximum: 23 characters. The time that the MasterSwitch PDU waits before applying power to outlets after AC power is applied to the unit. The longest reboot duration of any outlet in the group of accessible outlets. You can change this value only by modifying the Reboot Duration of individual accessible outlets. Sequenced Reboot and Delayed Sequenced Reboot use this value. Outlet Configuration Item Outlet Name Power On Delay Power Off Delay Reboot Duration URL Links Definition The name that identifies the outlet. Maximum: 23 characters. The time that the outlet waits before turning on after the command is issued. Delayed On, Sequenced Reboot, and Delayed Sequenced Reboot use this value. The time that the outlet waits before turning off after the command is issued. Delayed Off, Delayed Reboot, and Delayed Sequenced Reboot use this value. The time that the outlet will remain off during a reboot. Immediate Reboot and Delayed Reboot use this value. Defines HTTP links to relevant Web pages. MasterSwitch Power Distribution Unit User s Guide 11
16 Menu Items Event Log Displaying the Event Log To display the Event Log, select the Event Log menu in the Web interface or press CTRL + L in the Control Console interface. The Event Log displays the following information for the most recent 300 events for the MasterSwitch PDU. Item Date Time Event Description The date on which the event occurred (DD/MM/YYYY) The time at which the event occurred (HH:MM:SS) Description of the event. Retrieving the Event Log by using FTP To retrieve the Event Log using client-side FTP: 1. From an MS-DOS prompt, type ftp card-ip, where card-ip is the IP address of your MasterSwitch PDU. 2. After you log into the unit's FTP server, type dir. The screen displays information similar to the following: ftp>dir 200 Command okay. 150 Opening data connection for /. --wx-wx-wx 1 apc apc Jul aos253.bin --wx-wx-wx 1 apc apc Jul msp202.bin -r--r--r-- 1 apc apc 4096 Jul event.txt 226 Closing data connection. ftp: 194 bytes received in 0.00Seconds Kbytes/sec. ftp> Continued on next page MasterSwitch Power Distribution Unit User s Guide 12
17 Menu Items Event Log continued Retrieving the Event Log by using FTP, continued Using a spreadsheet to view the Event Log 3. Type get event.txt. The MasterSwitch PDU transmits the Event Log, containing at least the last 300 events, to your specified drive. The screen displays information similar to the following. ftp>get event.txt 200 Command okay. 150 Opening data connection for event.txt 226 Closing data connection. ftp: 3694 bytes received in 0.11Seconds 33.58Kbytes/sec. ftp> To view the event.txt file after you obtain it, use a spreadsheet application. The file is TAB-delimited for automatic formatting of columns. Note: When you import the event.txt file into a spreadsheet, the spreadsheet may display the year in the date fields as only two digits instead of the four digits logged and displayed by the MasterSwitch PDU. To display the year as four digits, select a four-digit date format in the spreadsheet. The event.txt file also includes the following information that is not shown in the Web and Control Console Event Log screens: The version of the event.txt file format (first field). The date and time at which the event.txt file was retrieved. The Name, Contact, Location, and IP address for the unit s Management Card. A unique Event Code for every type of event. Deleting the Event Log in the FTP interface To delete the Event Log, type del event.txt. You are not prompted to confirm the deletion. The screen displays information similar to the following: ftp>del event.txt 250 Requested file action okay, completed. ftp> A new event.txt file is created immediately in response to the Deleted Log event. MasterSwitch Power Distribution Unit User s Guide 13
18 Menu Items Network TCP/IP The TCP/IP section of the Network menu displays settings for the MasterSwitch PDU and allows you to configure the following TCP/IP settings. Item System IP Subnet Mask Default Gateway BOOTP Description The IP address of the MasterSwitch PDU The network subnet mask The local default gateway (router address) Enables or disables BOOTP requests for TCP/IP settings at startup. TFTP/FTP For control of file transfers, the TFTP/FTP section allows access to the following menu items on the TFTP/FTP menu for the TFTP and FTP Client and the FTP Server. Client or Server Menu Item Definition TFTP Client Remote Server IP: The network address of the TFTP server used for downloads. FTP Client FTP Server Remote Server IP: User Name: Password: Access: Port: The network address of the FTP server used for downloads. The user name for access to the FTP server. The password for access to the FTP server. Enable or Disable FTP server access. The TCP/IP port on which the FTP server for the MasterSwitch PDU is located. Default: port 21 Continued on next page MasterSwitch Power Distribution Unit User s Guide 14
19 Menu Items Network continued Telnet/Web T. Port Telnet Web Menu Item Access Port Access Port Definition Enables or Disables Telnet access. The TCP/IP port where the Telnet server for the MasterSwitch PDU resides. Default: port 23 Enables or Disables Web access. The TCP/IP port where the Web server for the MasterSwitch PDU resides. Default: port 80 SNMP The SNMP section of the Network menu displays the following SNMP settings: Item SNMP Access Access Control Trap Receiver Definition Enables or disables SNMP access. Controls access to each of the four SNMP channels. Defines up to four network management stations (NMSs) to which traps are sent. Continued on next page MasterSwitch Power Distribution Unit User s Guide 15
20 Menu Items Network continued SNMP, continued Access control. The Access Control section of the SNMP menu identifies the current settings for all four SNMP channels and provides the configurable values for a selected channel. Item Community Name NMS IP Access Type Definition The password that the NMS (identified by the NMS IP option) must use for SNMP access to the MasterSwitch PDU. The allowed access type is defined by the Access Type option. Maximum: 15 characters. Limits access to the NMS or NMSs specified. You specify the value as a specific IP address for one NMS or as an IP address filter for multiple IP addresses. For example: allows only the NMS with the specific IP address of to have access allows access for any NMS on the segment allows access for any NMS on the segment allows access for any NMS on the 159 segment or allows access for any NMS. Defines what actions the NMS that is identified by the NMS IP option can perform: Write: The NMS can use GETs and SETs. Read: The NMS can use only GETs. Disabled: The NMS can use neither GETs nor SETs. Trap Receiver. The Trap Receiver section of the SNMP menu identifies the current settings for all four trap receivers and allows you to change the values for a selected trap receiver. Item Community Name Receiver NMS IP Trap Generation Authentication Traps Definition The password that the MasterSwitch PDU uses when it sends traps to the NMS identified by the Receiver NMS IP option. Maximum: 15 characters. The IP address of the NMS that will receive traps sent by the MasterSwitch PDU. Note: To send no traps to any NMS, set as the Trap Receiver IP. Enables or Disables the ability of the MasterSwitch PDU to send traps to the NMS identified by the Receiver NMS IP option. Enables or Disables the ability of the MasterSwitch PDU to send authentication traps to the NMS identified by the Receiver NMS IP option. MasterSwitch Power Distribution Unit User s Guide 16
21 Menu Items System User Manager The User Manager section of the System menu displays the following configurable properties of the Administrator and Device Manager accounts. Administrator Account Item Auto Logout Authentication Definition The amount of time the user can be inactive on the system before being logged out automatically. Default: 3 minutes. One of the following settings: Basic: Causes the Web Interface to use standard HTTP 1.1 login (base64-encoded passwords). MD5: Causes the Web Interface to use an MD5-based authentication login. For MD5 authentication to function properly, you must have cookies enabled in your browser. Default: Basic User Name Password Authentication Phrase The user name. Access: Administrator only Maximum: 10 characters Default: apc The password for HTTP 1.1 authentication only Access: Administrator only Maximum: 10 characters Default: apc The password for MD5 only. Access: Administrator only Minimum: 15 characters Maximum: 32 characters Default: admin user phrase Continued on next page MasterSwitch Power Distribution Unit User s Guide 17
22 Menu Items System continued User Manager, continued Device Manager Account Item Definition User Name Password Authentication Phrase The user name. Maximum: 10 characters Default: device The password for HTTP 1.1 authentication only. Maximum: 10 characters Default: apc The password for MD5 only. Minimum: 15 characters Maximum:32 characters Default: device user phrase Continued on next page MasterSwitch Power Distribution Unit User s Guide 18
23 Menu Items System continued Outlet User Management You can create up to 16 independent Outlet User accounts for a MasterSwitch PDU. Current Outlet User List. The list shows the existing outlet user accounts and the outlets to which they have access. To select an existing account to edit or delete, click on the underlined user name, To add a user, select Add New User. Configure the Outlet User Account Settings. Following are the configurable settings for Outlet User Manager.. Item User Name Password Authentication Phrase User Description Account Status MasterSwitch Outlet Access Delete User Definition The outlet user name for both HTTP 1.1 and MD5 authentication. Maximum: 10 characters Note: If the User Name is in orange, the user account has been disabled. The outlet user password for HTTP 1.1 authentication. Maximum: 10 characters The Outlet user authentication phrase for MD5. Minimum: 15 characters Maximum: 32 characters. A descriptive Identification of the outlet user. Maximum: 30 characters Enables, disables, or deletes the outlet user s account. Note: A disabled account prevents the Outlet User of the account from logging in. The User Name is in orange if the account has been disabled. Selects the specific outlets to which an outlet user will have access. To delete an account, change the Account status to delete Outlet User, or click Delete User. Continued on next page MasterSwitch Power Distribution Unit User s Guide 19
24 Menu Items System continued Identification Item Name Contact Location Definition The system name used to identify the device. Name will be used for the sysname OID in the SNMP agent. The contact for or owner of the device. Contact will be used for the syscontact OID in the SNMP agent. The physical location of the device. Location will be used for the syslocation OID in the SNMP agent. Date/Time. Item Date Time Definition The date for the system in the following format: MM/DD/YY. The time for the system in the following format: HH:MM:SS (24-hour time). Continued on next page MasterSwitch Power Distribution Unit User s Guide 20
25 Menu Items System continued File Transfer The File Transfer section of the System menu provides access for managing file transfers. Item Remote TFTP Server IP Remote FTP Server IP Remote FTP Server User Name Remote FTP Server Password Filename Result of Last File Transfer Initiate File Transfer Via Description The IP address of the remote TFTP server defined in the Network menu s TFTP/FTP settings. TFTP: Remote Server IP The IP address of the remote FTP server defined in the Network menu s TFTP/FTP settings. FTP: Remote Server IP The user name for the FTP server defined in the Network menu s TFTP/FTP settings. FTP Client: User Name The password for the FTP server defined in the Network menu s TFTP/FTP settings. FTP Client: Password The name of the file to be downloaded. Displays the results of the last file transfer. Lets you choose whether the file will be transferred by TFTP or FTP. Continued on next page MasterSwitch Power Distribution Unit User s Guide 21
26 Menu Items System continued Tools Item Definition No Action Reboot Card Reset Card to Defaults Reset Card to Defaults Except TCP/IP Causes no action. Restarts the operation of the Management Card, but does not affect the state of the MasterSwitch outlets. Restores all configuration settings, including TCP/IP settings and user accounts, to their defaults and enables BOOTP. Restores all configuration settings to the default except TCP/IP settings. Links The link names that you configure appear on the navigation menu at the left in the Web interface. (The APC links are pre-defined but can be changed.). Link Type User Links APC Links Item Name URL Name URL Definition A link name that will appear on the menu bar. Up to 3 are allowed. The HTTP link in URL form for the link name specified as Name: View the names of the APC links. Define the URL of each APC link. Note: Only the Web interface of the MasterSwitch PDU displays hyperlinks and allows you to define them. MasterSwitch Power Distribution Unit User s Guide 22
27 Menu Items Help Contents The Contents screen provides an overview of many parameters reported and configured through the Web and Control Console interfaces. Accessing and Navigating the Online Help To access the online help, do one of the following: In the Web interface, select Help at the lower left in the navigation frame. In the Control Console, type? to access the Help menu. When using any menu, you can access the internal help pages by clicking? at the end of the black title bar APC Interactive Assistant APC Interactive Assistant brings APC Customer Service to the Web. When you select APC Interactive Assistant, the MasterSwitch PDU transmits information to the APC Interactive Assistant server. The server then provides customized up-to-date product information (such as whether a later version of firmware is available) and provides access to extensive context-sensitive help. About Card About Card provides the following information about the MasterSwitch PDU: The serial number The hardware revision The date and time at which the application version and APC OS information was loaded. MasterSwitch Power Distribution Unit User s Guide 23
28 Security Security Features MasterSwitch Power Distribution Unit Planning and implementing security features As a network device that passes information across the network, the MasterSwitch PDU is subject to the same exposure as other devices on the network. Use the information in this section to plan and implement the security features appropriate for your environment. Port assignments If a Telnet, FTP, or Web server uses a non-standard port, a user must specify the port when using the client interface, such as a Web browser. The non-standard port address becomes an extra password, hiding the server to provide an additional level of security. The TCP ports for which the Telnet, FTP, and Web servers listen are initially set at the standard well known ports for the protocols.to hide the interfaces, use any port numbers from 5000 to User names, passwords, community names All user names, passwords, and community names for SNMP are transferred over the network as plain text. A user who is capable of monitoring the network traffic can determine the user names and passwords required to log in to the Administrator, Device Manager, and Outlet User accounts of the Control Console or Web interface of a MasterSwitch PDU. This security limitation of the protocols affects any device using Telnet, a Web server, or an SNMP version 1 agent. MasterSwitch Power Distribution Unit User s Guide 24
29 Security Authentication Authentication versus encryption The MasterSwitch PDU controls access by providing basic authentication through user names, passwords, and IP addresses, but provides no type of encryption. These basic security features are sufficient for most environments, in which sensitive data is not being transferred. To ensure that data and communication between the MasterSwitch PDU and the client interfaces, such as Telnet and the Web browser, cannot be captured, you can provide a greater level of security by enabling MD5 authentication (described below) for the Web interface. MD5 authentication (Web interface) The Web interface option for MD5 authentication enables a higher level of access security than the basic HTTP authentication scheme. The MD5 scheme is similar to CHAP and PAP remote access protocols. Enabling MD5 implements the following security features: The Web server requests a user name and a password phrase (distinct from the password). The user name and password phrase are not transmitted over the network, as they are in basic authentication. Instead, a Java login applet combines the user name, password phrase, and a unique session challenge number to calculate an MD5 hash number. Only the hash number is returned to the server to verify that the user has the correct login information; MD5 authentication does not reveal the login information. In addition to the login authentication, each form post for configuration or control operations is authenticated with a unique challenge and hash response. After the authentication login, subsequent page access is restricted by IP addresses and a hidden session cookie. (You must have cookies enabled in your browser.) Pages are transmitted in their plain-text form, with no encryption. Continued on next page MasterSwitch Power Distribution Unit User s Guide 25
30 Security Authentication continued MD5 authentication (Web interface), continued If you use MD5 authentication, which is available only for the Web interface, disable the less secure interfaces, including Telnet, FTP, and SNMP. For SNMP, you can disable write-only access so that read access and trap facilities are still available. Although MD5 authentication provides a much higher level of security than the plain-text access methods, complete protection from security breaches is almost impossible to achieve. Well-configured firewalls are an essential element in an overall security scheme. For additional information on MD5 authentication, see RFC document #1321 at the Web site of the Internet Engineering Task Force. For CHAP, see RFC document #1994. Continued on next page MasterSwitch Power Distribution Unit User s Guide 26
31 Security Authentication continued Summary of access methods Interface Security Access Notes Serial Control Console Access is by user name and password. Always enabled. These methods are available: Telnet Control Console User name and password Selectable server port Server Enable/Disable The user name and password are transmitted as plain text. SNMP These methods are available: Community Name NMS IP filters Agent Enable/Disable Four access communities with read/write/disable capability NMS IP filters allow access from either one IP address or from multiple IP addresses. You specify multiple NMSs not by their literal IP addresses but in the format of an NMS IP filter. See Access control on page 16 for more information. These methods are available: FTP Server User name and password Selectable server port Server Enable/Disable Only the Administrator account has access. Web Server These methods are available: User name and password Selectable server port Server Enable/Disable MD5 Authentication option In basic HTTP authentication mode, the user name and password are transmitted base-64 encoded (with no encryption). MD5 authentication mode uses a user name and password phrase. MasterSwitch Power Distribution Unit User s Guide 27
32 MasterSwitch Power Distribution Unit Product Information Warranty Information Limited warranty American Power Conversion (APC) warrants the MasterSwitch PDU to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser. Obtaining service To obtain service under warranty, you must obtain a Returned Material Authorization (RMA) number from APC or a designated APC service center. Products must be returned to APC or to an APC service center with transportation charges prepaid and must be accompanied by a brief description of the problem and proof of date and place of purchase. See Contacting Customer Support on page 29 for more information, including packaging, shipping, and labeling requirements for returned products. Warranty exclusions Except as provided herein, American Power Conversion makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. Except as provided above, in no event will APC be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of this product, even if advised of the possibility of such damage. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. MasterSwitch Power Distribution Unit User s Guide 28
33 Product Information Obtaining Customer Support Contacting Customer Support To obtain customer support for problems with the MasterSwitch PDU: 1. Contact Customer Support at a phone number or address listed under APC Worldwide Customer Support on page 34, and be ready to provide the serial number and date of purchase of the MasterSwitch PDU. 2. Be prepared to provide a description of the problem so that the technician can attempt to solve the problem over the phone. 3. If phone consultation cannot solve the problem, the technician will give you a Return Material Authorization (RMA) number. If the MasterSwitch PDU is under warranty, repair or replacement is free of charge. If the warranty has expired, there will be a charge for repair or replacement. 4. If you are asked to return the MasterSwitch PDU, pack the unit carefully. Damage sustained in transit is not covered by the warranty. Enclose a letter in the package with your name, address, RMA number, a copy of the sales receipt, your daytime phone number, and a check as payment (if applicable). Mark the RMA number clearly on the outside of the shipping carton. The factory will not accept any materials without this marking. 5. Return the MasterSwitch PDU by insured, prepaid carrier to the address provided by the technician. MasterSwitch Power Distribution Unit User s Guide 29
34 Product Information Life-Support Policy General policy American Power Conversion (APC) does not recommend the use of any of its products in the following situations: In life-support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life-support device or to affect significantly its safety or effectiveness. In direct patient care. APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of American Power Conversion is adequately protected under the circumstances. Examples of lifesupport devices The term life-support device includes but is not limited to neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators (for adults or infants), anesthesia ventilators, infusion pumps, and any other devices designated as critical by the U.S. FDA. Hospital-grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems. APC does not claim that units with these modifications are certified or listed as hospital-grade by APC or any other organization. Therefore these units do not meet the requirements for use in direct patient care. MasterSwitch Power Distribution Unit User s Guide 30
35 Product Information Specifications Product specifications for AP9211 The following table shows the product specifications for the MasterSwitch PDU with the part number AP9211. Type of Specification Item Specification Electrical Input: Nominal input voltage Acceptable input voltage Nominal input frequency Overcurrent protection Input connector Output: Output connectors Maximum total current draw: 100/120 VAC VAC 50/60 Hz 15-A circuit breaker 15 ft (4.5 m) attached NEMA 5-15 line cord Eight NEMA 5-15 outlets 12 A Physical Size (H W D) in ( cm) Environmental Weight: Shipping weight: Elevation (above MSL): Operating Storage Temperature: Operating Storage Operating Humidity: 6.0 lb (2.7 kg) 7.5 lb (3.4 kg) 0 to 10,000 ft (0 to 3000 m) 0 to 50,000 ft (0 to m) 32 to 104 F (0 to 40 C) 32 to 113 F (0 to 45 C) 0 to 95%, non-condensing Approvals for AP9211 The following table shows the approvals for the MasterSwitch PDU with the part number AP9211. Type Approval EMC verification: Safety Agency: FCC Class A; DOC Class A; VCCI CSA; UL Continued on next page MasterSwitch Power Distribution Unit User s Guide 31
36 Product Information Specifications continued Product specifications for AP9212 The following table shows the product specifications for the MasterSwitch PDU with the part number AP9212. Type of Specification Item Specification Electrical Physical Environmental Input: Nominal input voltage Acceptable input voltage Nominal input frequency Overcurrent protection Input connector Output: Output connectors Maximum total current draw: Size (H W D) Weight: Shipping weight: Elevation (above MSL): Operating Storage Temperature: Operating Storage Operating Humidity: VAC VAC 50/60 Hz 12-A circuit breaker IEC-320 C14 inlet and IEC-320 C13-to-C14 power extender cord (2m) Eight IEC-320 C13 outlets 10 A in ( cm) 4.5 lb (2.0 kg) 6.0 lb (2.7 kg) 0 to 10,000 ft (0 to 3000 m) 0 to 50,000 ft (0 to m) 32 to 104 F (0 to 40 C) 32 to 113 F (0 to 45 C) 0 to 95%, non-condensing Approvals for AP9212 The following table shows the approvals for the MasterSwitch PDU with the part number AP9212. Type Approval EMC verification: CE with CISPR 22 and 24 Safety Agency: VDE; IEC MasterSwitch Power Distribution Unit User s Guide 32
37 Web/SNMP Management SmartSlot Card Index A About Card, 23 Access limiting NMS access by IP address, 16, 27 Account types access to menus for each type, 8 Administrator, 17 Device Manager, 18 Outlet User, 19 Administrator account, 17 Approvals AP9211, 31 AP9212, 32 Authentication, 25 Auto-configuration, 4 C Configuration auto-configuration, 4 customizing, 4 FTP, 14 TCP/IP settings, 4 Telnet port, 15 TFTP, 14 using menu options, 9 Web port, 15 Configure Device Settings, 11 Contents screen, 23 Control Console interface, 6 Customer Support, contacting, 34 Customizing configuration, 4 D Date/Time section, System menu, 20 Deleting the Event Log, 13 Device Manager account, 18 E Encryption not supported, 25 Event Log contents, deleting, 13 displaying, 12 menu, 12 retrieving wth FTP, 12 viewing as a spreadsheet, 13 F File Transfer, 21 Front panel, 1 H Help Help menu, 23 Interactive Assistant, 23 I Identification section, System menu, 20 Interactive Assistant, 23 Interfaces, management, 5 L LEDs, 2 Life-support policy, 30 Links section, System menu, 22 M Management interfaces Control Console, 6 Web, 5 Managing MasterSwitch, 5 MasterSwitch menu, 11 MD5 authentication, 25 Menu items, 9 Menus Event Log, 12 Help, 23 MasterSwitch, 11 Network, 14 Outlets, 10 System, 17 N Network menu, 14 O Online help, 23 Outlet Configuration, 11 Outlet Control Actions, 10 Outlet User accounts, 19 Outlet User Management, 19 Outlets menu, 10 P Panel front, 1 rear, 3 Password-protected accounts, 8 Port assignments, 24 Problems, persistent, 29 Product description, 1 Product information, 28 R Rear panel, 3 RMA (return material authorization) number, 28 S Security, 24 authentication, 25 features, 24 Service, obtaining, 28 Setup, initial, 4 SNMP section, Network menu, 15 Specifications AP9211, 31 AP9212, 32 System menu, 17 T TCP/IP configuring settings, 4, 14 Reset Card to Defaults except TCP/IP, 22 section of Network menu, 14 Telnet port, configuring, 15 TFTP/FTP section, Network menu, 14 Tools, 22 U User Manager, 17 W Warranty information, 28 Web interface, 5 Web port, configuring, 15 MasterSwitch Power Distribution Unit User s Guide 33
38 Contact Information APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge. You can contact APC Customer Support in any of the following ways: Use an APC web page to find answers to frequently asked questions (FAQs), to access documents in the APC Knowledge Base, and to submit customer support requests. (Corporate Headquarters) Connect by links to APC web pages for specific countries and regions, each of which provides customer support information. Submit customer support requests. Contact local or regional APC Customer Support by telephone or . For addresses and local, country-specific, customer support telephone numbers worldwide, go to For addresses and technical support telephone numbers of major APC regional customer support centers, use the following list: APC Headquarters (U.S.. and Canada) Latin America Europe, Middle East, Africa Japan (1) (800) (toll free) (1) (401) (United States) (353) (91) (Ireland) (03) Contact the APC representative or other distributor from whom you purchased your APC hardware device or APC software application for information on how to obtain local customer support. Entire contents copyright 2000 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC and NetShelter are registered trademarks of American Power Conversion Corporation. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only B 07/2000
MasterSwitch Power Distribution Unit
MasterSwitch Power Distribution Unit AP9211 AP9212 AP9217 AP9218 User s Guide Contents MasterSwitch Power Distribution Unit Introduction................................. 1 Product Description.............................
Environmental Monitoring Unit
Environmental Monitoring Unit AP9312TH AP9312THi User s Guide Contents Environmental Monitoring Unit Managing the Unit............................ 1 Introduction.................................. 1 Available
Triple Expansion Chassis
Triple Expansion Chassis AP9604 Installation Manual Contents Introduction............................. 1 Installation.............................. 2 Power Considerations...................... 5 Operations..............................
Out-of-Band Management Card
Out-of-Band Management Card AP9608 Installation Manual Related Documents For information on using the Out-of-Band Management Card after installation and startup, see the online User s Guide specific to
Title Page Web/SNMP Management SmartSlot Card
Title Page Web/SNMP Management SmartSlot Card AP9606 User s Guide Thank You! Thank you for selecting the APC Web/SNMP Management SmartSlot Card. It has been designed for many years of reliable, maintenance-free
Metered Rack Power Distribution Unit
Metered Rack Power Distribution Unit AP7830 AP7840 Installation and Quick Start Contents Product Description and Inventory...................... 1 Additional documentation......................... 2 Inventory.....................................
Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7
Contents Introduction--1 Product Description.................................. 1 Internal Management Features........................... 3 Front Panel........................................ 5 Watchdog
Network Management Card. Installation and Quick Start Manual
Network Management Card Installation and Quick Start Manual Radio frequency interference Changes or modifications to this unit not expressly approved by the party responsible for compliance could void
APC Step-Down Transformer. User s Manual
APC Step-Down Transformer Models: AP9621, SURT005, SURT006, SUTF3, SYTF2, SYTF2J, SYTF3 and SYTF3J User s Manual English 990-7820D, July 2003 TABLE OF CONTENTS APC Contact Numbers and Support Visit the
USER S GUIDE Switched Rack PDU
Contents Introduction--1 Product Description....................................... 1 Access Procedures....................................... 3 Recover From a Lost Password..............................
How to Log On... 15 Main Screen... 18 Control Console Menus... 21. How to Log On... 24 Summary Page... 27 Navigation Menu... 29
Contents Introduction--1 Product Description.................................. 1 Access Procedures.................................... 3 How to Recover From a Lost Password..................... 6 Upgrading
Network Management Card Wizard--1. Introduction... 1 Using the Network Management Card Wizard... 5
Contents Network Management Card Wizard--1 Introduction....................................... 1 Using the Network Management Card Wizard................ 5 File Transfers--10 Introduction......................................
Wireless Router Setup Manual
Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,
VoIP Zone Controller: 4-Port Audio Out Operations Guide
The IP Endpoint Company VoIP Zone Controller: 4-Port Audio Out Operations Guide SiP Compliant 010881 Document Part #930109D for Firmware Version 1.0.6 CyberData Corporation 3 Justin Court Monterey, CA
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
Network-Enabled Devices, AOS v.5.x.x. Content and Purpose of This Guide...1 User Management...2 Types of user accounts2
Contents Introduction--1 Content and Purpose of This Guide...........................1 User Management.........................................2 Types of user accounts2 Security--3 Security Features.........................................3
User s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Starting a Management Session
Management Software AT-S63 Starting a Management Session AT-S63 Version 2.2.0 for the AT-9400 Layer 2+ Switches AT-S63 Version 3.0.0 for the AT-9400 Basic Layer 3 Switches 613-000817 Rev. A Copyright 2007
Web Power Switch III User s Guide Revision LPC-3
Web Power Switch III User s Guide Revision LPC-3 Web Power Switch III Features Congratulations on your purchase. The Web Power Switch III is a cost-effective AC power switch for remote control and reboot.
Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005
Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)
Welcome. Unleash Your Phone
User Manual Welcome Unleash Your Phone For assistance with installation or troubleshooting common problems, please refer to this User Manual or Quick Installation Guide. Please visit www.vonage.com/vta
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B
Management Software AT-S84 User s Guide For the AT-9000/24 Layer 2 Gigabit Ethernet Switch Version 1.1 613-000368 Rev. B Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication
PE6108/PE6208/PE8108/PE8208
Energy Intelligence Solutions PE6108/PE6208/PE8108/PE8208 eco PDU Distribution Unit ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency
Router Setup Manual. NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17
NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear, Inc. Microsoft, Windows,
Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6
Contents Introduction 1 Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5 Initial Configuration Requirements 6 Overview 6 Setup Wizard 7 Status, Alarm,
How To Set Up An Andsl Modem Router For Internet Access
ADSL Modem Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10026-01 2006-2 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
UPS Network Interface. Quick InstallationGuide
UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I-00453 Rev B
User s Manual UPS SERIES Network Interface Card UPS-IPCARD I-00453 Rev B TABLE OF CONTENTS INTRODUCTION............................................................. 3-4 INSTALLATION GUIDE.......................................................
Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.
About This Guide This guide contains step-by-step instructions for setting up the D-Link DFL-260E/860E Firewall. Please note that the model you have purchased may appear slightly different from those shown
Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version 3.40 12/2004
Prestige 202H Plus ISDN Internet Access Router Quick Start Guide Version 3.40 12/2004 Table of Contents 1 Introducing the Prestige...3 2 Hardware Installation...4 2.1 Rear Panel...4 2.2 The Front Panel
IP Power Stone 4000 User Manual
IP Power Stone 4000 User Manual Two Outlet Remote AC Power Controller Multi Link, Inc. 122 Dewey Drive Nicholasville, KY 40356 USA Sales and Tech Support 800.535.4651 FAX 859.885.6619 techsupport@multi
CM500 High Speed Cable Modem User Manual
User Manual February 2015 202-11472-04 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label
Securely manage data center and network equipment from anywhere in the world.
LES1516A LES1532A LES1548A Secure Server with Cisco Pinout Securely manage data center and network equipment from anywhere in the world. To download the user manual, this quick start guide, and software
TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module
Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually
USER S GUIDE. network management card. Contents. Introduction--1. Control Console--13
Contents Introduction--1 Product Description.................................. 1 Functionality 1 Initial set-up 2 Network management features 3 Internal Management Features........................... 5
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your Wireless-G Router Model WGR614v9. You can access these features by selecting the items under
Expert Power Control NET 4x 8212 / 8213
2010 Gude Analog- und Digitalsysteme GmbH 2010 Gude Analog- und Digitalsysteme GmbH 23.08.2010 Content 3 Table of content Kapitel 1 Security Advise 5 Kapitel 2 Description 5 Kapitel 3 Hardware 6 3.1 Content
Firewall VPN Router. Quick Installation Guide M73-APO09-380
Firewall VPN Router Quick Installation Guide M73-APO09-380 Firewall VPN Router Overview The Firewall VPN Router provides three 10/100Mbit Ethernet network interface ports which are the Internal/LAN, External/WAN,
Network Management Card
Network Management Card AP9617 AP9618 AP9619 Installation and Quick-Start Manual How to Avoid Equipment Damage Disconnect UPS power You do not need to turn off a Symmetra or a Silcon model UPS to install
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,
DSL-2600U. User Manual V 1.0
DSL-2600U User Manual V 1.0 CONTENTS 1. OVERVIEW...3 1.1 ABOUT ADSL...3 1.2 ABOUT ADSL2/2+...3 1.3 FEATURES...3 2 SPECIFICATION...4 2.1 INDICATOR AND INTERFACE...4 2.2 HARDWARE CONNECTION...4 2.3 LED STATUS
SNMP-NET UPS SNMP Card (Web-Based monitoring SNMP Card)
UPS SNMP Card (Web-Based monitoring SNMP Card) User s Manual PN: 34000281 R1 Table of Contents Chapter 1 Introduction...3 Features...3 System Application...3 Chapter 2 Installation...4 SNMP-NET Chapter
your Gateway Windows network installationguide 802.11b wireless series Router model WBR-100 Configuring Installing
your Gateway Windows network installationguide 802.11b wireless series Router model WBR-100 Installing Configuring Contents 1 Introduction...................................................... 1 Features...........................................................
USER S GUIDE. network management card. Contents. Introduction--1. Control Console--13
Contents Introduction--1 Product Description.................................. 1 Features 1 Initial set-up 2 Network management features 3 Internal Management Features........................... 4 Overview
SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES
SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES www.unipowerco.com 2014 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive, Coral Springs,
User s Guide. Managed Rack Power Distribution Unit
User s Guide Managed Rack Power Distribution Unit Contents Introduction--1 Product Features......................................... 1 Getting Started........................................... 4 Establishing
NMS300 Network Management System
NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate
ZyWALL 5. Internet Security Appliance. Quick Start Guide Version 3.62 (XD.0) May 2004
ZyWALL 5 Internet Security Appliance Quick Start Guide Version 3.62 (XD.0) May 2004 Introducing the ZyWALL The ZyWALL 5 is the ideal secure gateway for all data passing between the Internet and the LAN.
SNMP-1 Configuration Guide
SNMP-1 Configuration Guide You must configure the Net Logic Card before it can operate properly. You have two methods to configure the Net Logic Card: Using telnet or terminal. Using Telnet 1. Make sure
Link Link sys E3000 sys RE1000
User Guide High Performance Extender Wireless-N Router Linksys Linksys RE1000 E3000Wireless-N Table of Contents Contents Chapter 1: Product Overview 1 Front 1 Top 1 Bottom 1 Back 2 Chapter 2: Advanced
FXM Communication Manual
Operator s Manual 017-201-B1 9/06 EFFECTIVE: September, 2006 Alpha Technologies Power Alpha Technologies 1 Introduction to FXM Computer Communication There are several ways to connect a computer to the
PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
Trademarks Copyright PLANET Technology Corp. 2004 Contents subject to revise without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Wireless-N Gigabit Router WNR3500. You can access these features by selecting the items
NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2
NetProbe Lite Web Based 8 Channel Sensor Collector User Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission
Alarm Messages... 15 Clearing the Hardware Alarms... 16. How to Log On... 17 Summary Page... 21 Navigation Menu... 24
Contents Introduction--1 Product Description.................................. 1 Access Procedures................................... 3 How to Recover from a Lost Password..................... 6 Upgrading
Powerware Environmental Rack Monitor User s Guide
Powerware Environmental Rack Monitor User s Guide FCC Part 15 Class B EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
HG659 Home Gateway. User Guide HUAWEI TECHNOLOGIES CO., LTD.
HG659 Home Gateway User Guide HUAWEI TECHNOLOGIES CO., LTD. Product Overview...................................... 1 Ports and Buttons.................................................. Indicators.........................................................
OfficeConnect Internet Firewall 25 Internet Firewall DMZ. QuickStart Guide (3C16770, 3C16771)
OfficeConnect Internet Firewall 25 Internet Firewall DMZ QuickStart Guide (3C16770, 3C16771) Checking Package Contents Getting Started Thank you for purchasing the OfficeConnect Internet Firewall. The
CM400 High Speed Cable Modem User Manual
User Manual July 2015 202-11412-02 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of
Acano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B
Acano solution Acano Solution Installation Guide Acano January 2014 76-1002-03-B Contents Contents 1 Introduction... 3 1.1 Before You Start... 3 1.1.1 Safety information... 3 1.1.2 You will need the following
Multi-Homing Dual WAN Firewall Router
Multi-Homing Dual WAN Firewall Router Quick Installation Guide M73-APO09-400 Multi-Homing Dual WAN Firewall Router Overview The Multi-Homing Dual WAN Firewall Router provides three 10/100Mbit Ethernet
WebPower UPS SNMP HTTP AGENT
WebPower UPS SNMP HTTP AGENT User Guide WebPowerPro_man_E420 AT, IBM are registered trademarks of International Business Machines Corporation. NetWare are registered trademarks of Novell, Incorporated.
LifeSize Networker Installation Guide
LifeSize Networker Installation Guide November 2008 Copyright Notice 2006-2008 LifeSize Communications Inc, and its licensors. All rights reserved. LifeSize Communications has made every effort to ensure
Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide
English CHAPTER 1 Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide Cisco One-Year Limited Hardware Warranty Terms Easy Installation: Try These Steps First! (CRWS Users) Overview
PE8216/PE8324. Energy Intelligence Solutions
PE8216/PE8324 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The
APC IP KVM QuickStart Guide
APC IP KVM QuickStart Guide Use this guide to install and configure the American Power Conversion (APC ) IP Keyboard Video Mouse (KVM) Switch and related products. See the APC IP KVM Installation, Configuration,
User s Guide. Network Management Card AP9631-IBM
User s Guide Network Management Card AP9631-IBM Contents Introduction... 1 Product Description....................................... 1 Features................................................ 1 Initial
User s Guide. SNMPWEBCARD Firmware Version 12.06.0062 through 12.06.0065 Revision A
WARRANTY REGISTRATION: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty User s Guide SNMPWEBCARD Firmware Version 12.06.0062 through 12.06.0065 Revision A
SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0
SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0 Before You Begin Before you install the SOHO 6 Wireless, you must have: A computer with a 10/100BaseT Ethernet card
SNMP Manager User s Manual
SNMP Manager User s Manual Table of Contents 1. Introduction...2 2. SNMP Manager Install, Quick Start and Uninstall...2 2.1. Software Installation...2 2.2. Software Quick Start...2 2.3. Software Uninstall...2
Sharp Remote Device Manager (SRDM) Server Software Setup Guide
Sharp Remote Device Manager (SRDM) Server Software Setup Guide This Guide explains how to install the software which is required in order to use Sharp Remote Device Manager (SRDM). SRDM is a web-based
Broadband Phone Gateway BPG510 Technical Users Guide
Broadband Phone Gateway BPG510 Technical Users Guide (Firmware version 0.14.1 and later) Revision 1.0 2006, 8x8 Inc. Table of Contents About your Broadband Phone Gateway (BPG510)... 4 Opening the BPG510's
Switched Rack Power Distribution Unit
Switched Rack Power Distribution Unit AP7922 Installation and Quick Start This manual is available in English on the enclosed CD. Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar. Este
Broadband ADSL2+ Modem DM111PSPv2
Broadband ADSL2+ Modem DM111PSPv2 User Manual 350 East Plumeria Drive San Jose, CA 95134 USA August 2011 202-10913-01 v1.0 2011 NETGEAR, Inc. All rights reserved No part of this publication may be reproduced,
Ultra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
Dominion PX. General Questions. What is Dominion PX (PX)?
Dominion PX Question General Questions What is Dominion PX (PX)? Is Raritan new to the rack power distribution unit market? Can the PX be used as a stand-alone device? Does PX work with Raritan s CommandCenter
Crow Limited Warranty. Print Version 017
Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose
Chapter 7 Troubleshooting
Chapter 7 Troubleshooting This chapter provides troubleshooting tips and information for your ProSafe VPN Firewall 200. After each problem description, instructions are provided to help you diagnose and
Firmware upgrade instructions for the Web/SNMP and Network
Page 1 of 6 Answer ID 768 Firmware upgrade instructions for the Web/SNMP and Network Management Cards Question How do I upgrade the firmware on an APC Web/SNMP Management Card or Network Management Card?
How To Check If Your Router Is Working Properly
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Dual Band Wireless-N Router WNDR3300. You can access these features by selecting the
Chapter 4 Management. Viewing the Activity Log
Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in
Overview of WebMux Load Balancer and Live Communications Server 2005
AVANU Load Balancing for Microsoft Office Live Communications Server 2005 WebMux Delivers Improved Reliability, Availability and Scalability Overview of WebMux Load Balancer and Live Communications Server
SecureLinx Spider Duo Quick Start Guide
SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...
Dominion KX II-101-V2
Dominion KX II-101-V2 Quick Setup Guide Thank you for your purchase of the Dominion KX II-101-V2, the economical, full-featured, single-port digital KVM-over-IP device. For details on using the KX II-101-V2,
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported
Network Management Card
Network Management Card Installation manual IP= MAC=00E0D8FF855E Reset 100 10 data Card Settings 1 2 RS232 Download ETHERNET RS232 66074 34003641EN/AG - Page 1 1 2 1 2 Quick start ASI or STS U-Talk ASI
User s Manual. Remote Management Card RMCARD202. Intelligent Remote Management Card allows a UPS system to be managed, monitored, and configured
User s Manual Remote Management Card RMCARD202 Intelligent Remote Management Card allows a UPS system to be managed, monitored, and configured Version 1.2 TABLE OF CONTENTS Introduction 1 Installation
Prestige 650R-31/33 Read Me First
Prestige 650R-31/33 Read Me First Prestige Rear Panel Connections PORT DSL CONSOLE LAN 10/100M POWER Connect to a telephone jack using a telephone wire. CONNECTION Connect to a serial port (COM port) on
Quick Installation Guide of WLAN Broadband Router
To avoid users without access right through your WLAN Broadband Router, suggest that use security mechanism like WEP, WPA or set ID/password for web configuration login IP address 192.168.1.254. Preparation
While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.
AG082411 Objective: How to set up a 3G connection using Static and Dynamic IP addressing Equipment: SITRANS RD500 Multitech rcell MTCBAH4EN2 modem PC with Ethernet card Internet explorer 6.0 or higher
Broadband ADSL2+ Modem Model DM111Pv2 Setup Manual
Broadband ADSL2+ Modem Model DM111Pv2 Setup Manual NETGEAR, Inc. 350 East Plumeria Drive San Jose, CA 95134 USA October 2014 208-10256-02 v1.0 Support Thank you for selecting NETGEAR products. After installing
Prestige 660R-6x Read Me First
Prestige 660R-6x Read Me First Prestige Rear Panel Connections DSL PORT CONNECTION Connect the DSL port on the Prestige to the wall jack using the included DSL cable (telephone wire). Connect the micro