Low Profile Ultra ATA-133 RAID PCI Host



Similar documents
SATA 150 RAID. user. Model MAN UM

SATA II 4 Port PCI RAID Card RC217 User Manual

PCI ATA 133 RAID Controller Card. User Manual

Serial ATA RAID PCI. User's Manual

SATA RAID Function. (Only For Chipset Sil 3112 /Sil 3512 Used) USER S MANUAL 12M E-SI

Addonics. 4-Port External SATA II PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-E) User s Guide Revision 1.1 T E C H N O L O G I E S

Installation Guide. RAID 5 esata 3Gbps 2 external port Low profi le PCI Express card. GICe702S3R5W6 PART NO. M0557

Serial ATA RAID PCI Card

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

Serial ATA 4-Channel RAID Quick Installation Guide

ATA-133 IDE RAID Card. Version 1.1

RAID installation guide for Silicon Image SiI3114

SATA RAID SIL 3112 CONTROLLER USER S MANUAL

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

SATARAID5 Serial ATA RAID5 Management Software

Encore SATA2 RAID PCIe Card

Serial-ATA IDE Card. Version 1.0

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

SATA II PCIe RAID Quick Installation Guide

IDE2410 ATA-100 IDE RAID Card. Version 1.0

6-Port SATA II 150 PCI Host Card w/raid

SATARAID5 Serial ATA RAID5 Management Software. Users Manual

Serial ATA PCI Quick Installation Guide

Ultra ATA 133 RAID PCI Pro

VT8237 SATA RAID User Manual

RAID installation guide for ITE8212F

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

UltraATA 100 PCI RAID TM

ESATA PCI CARD. User s Manual

SATARaid Serial ATA RAID Management Software

SATA II PCIe RAID Quick Installation Guide

Serial ATA 2 Ports PCI Host

SATA II-150 PCI RAID

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

PCI SATA + PATA Raid Card

2-Serial/1-Parallel Port PCI Adapter RC303 User Manual

Guide to SATA Hard Disks Installation and RAID Configuration

Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2

PCI SATA RAID Card User Manual

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

Table of Contents 1. INTRODUCTION TO THE DC-200 RAID CARD... 3

SERIAL ATA HOST CONTROLLER CARD USER MANUAL SATA R SATA I WARNING

4+1 SATA II 300 IDE/PATA PCI-E. Combo Host Card w/ RAID & Port. Multiplier

The UltraATA 133 PCI is an ultra high-speed dual channel Ultra ATA/133 controller board for use in Pentium-class computer.

ITE RAID Controller USER MANUAL

Promise FastTrak 100-Lite RAID Controller

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

User manual Ver: 2.0. SATA Channel PCI RAID Card

NVIDIA RAID Installation Guide

VIA RAID configurations

esata 3.0Gbps RAID ExpressCard

Marvell SATA3 RAID Installation Guide

SATA II-150 PCI Quick Installation Guide


SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

SiI3132 SATARAID5 Storage Management Software User Manual

Intel Rapid Storage Technology

HP User Manual for LSI Integrated RAID on HP xw4200/xw6200/xw8200/xw9300 Workstation

AMD RAID Installation Guide

GigaRAID (IT8212) ATA RAID Controller USER S MANUAL

RAID Option Installation

Intel ESB2 SATA RAID Setup Guidelines

How To Set Up A Raid On A Hard Disk Drive On A Sasa S964 (Sasa) (Sasa) (Ios) (Tos) And Sas964 S9 64 (Sata) (

SiS964/SiS180 SATA w/ RAID User s Manual. Quick User s Guide. Version 0.3

PCI Express SATA / esata 6Gb/s RAID Card User Manual

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

Intel Matrix Storage Manager 8.x

Promise RAID Function

VIA RAID Installation Guide

AMD RAID Installation Guide

IDE ATA/133 Controller

AMD RAID Installation Guide

English. Configuring SATA Hard Drive(s)

VIA / JMicron RAID Installation Guide

Guide to SATA Hard Disks Installation and RAID Configuration

RAID configuration and driver installation guide

Configuring ThinkServer RAID 100 on the TS140 and TS440

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

4 Port PCI SATA RAID Controller Adapter Card

Server RSV-S8 User Manual

Guide to SATA Hard Disks Installation and RAID Configuration

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Chapter 2 Installation

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines

Guide to SATA Hard Disks Installation and RAID Configuration

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

Data Lifeguard Tools. Software Manual

RocketRAID User's Manual. Revision: 1.0 Date: Mar HighPoint Technologies, Inc.

Configuring ThinkServer RAID 100 on the Lenovo TS130

Chapter 3 Software Installation

How To Set Up Your Motherboard With A Power Supply And Power Supply On A Microtower 2.2 (Ios) With A Hard Disk Drive On A Mini Usb 2.3 (I386) With An External Hard Disk (I2)

Installing a printer in Windows 95.

FASTTRAK USER MANUAL TX2200, TX2300. Version 3.2

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

INTRODUCTION INSTALLING THE SCSI CARD 2940UW PRO

SATARAID5 Management Software User s Guide

ForceWare Software MediaShield User s Guide. Version 5.0

Transcription:

Low Profile Ultra ATA-133 RAID PCI Host User Manual English LINDY No. 70642 www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (November 2004)

1. Introduction This Low Profile Ultra ATA-133 RAID PCI Host Adapter is a PCI to dual Ultra ATA-133 host controller board which can support Low profile PCI and regular size PCI both. It provides a 32bit, 33/66 MHz PCI interface on the host side and dual, fully compliant Ultra ATA-133 ports on the device side to access ATA Hard disk drive. The board can be used to upgrade your desktop computer to have dual Ultra ATA-133 Channels and support RAID 0, RAID 1 and RAID 0+1 features. It comes completely with drivers for Windows 98, Windows Millennium, Windows NT 4.0, Windows 2000 and XP. RAID, Redundant Array of Independent Disks, greatly enhances two main areas of data storage: performance and data integrity. By using RAID 0, also known as Striping, performance of sustained data transfer rates is greatly enhanced by simultaneously writing data to 2, 3 or 4 drives. The second benefit of RAID is data redundancy. RAID 1, Mirroring, writes identical data on two drives or sets of drives, thus protecting the data from a disk failure. If, for any reason, one drive were to fail, your data is secure and available from the mirrored second drive. 1.1. Features 1.1.1. PCI Interface Compliant with PCI Specification, revision 2.2. Integrated PCI DMA engines. 32 bit, 33/66MHz fully compliant PCI host interface. 1.1.2. High Speed Ultra ATA-133 Interface Supports two independent ATA channels. Supports ATA 133. Supports full speed burst transfers on the ATA bus. Supports software-controlled ATA bus tri-state. Supports device specific timing registers. - 2 -

Supports device read-ahead and write-ahead capability under Virtual DMA. Features one 256-byte FIFO (32-bit x 64 deep) per IDE channel for host reads and writes. Features ATA to PCI interrupt masking. Features command buffering from the PCI to ATA. Features Virtual DMA: Bus master transfer on the PCI bus and PIO transfer on the ATA bus. Features Watch Dog Timer for fault resiliency. Provides RAID 0 (Stripping) to greatly increase the performance of data transfer by simultaneously writing data to 2 drives. Provides RAID 1 (Mirroring) to protect the data from a disk failure by writing identical data on 2 drives. RAID 0+1 (Mirrored-Stripping) combine both Striping and Mirroring technologies to provide both the performance enhancements that come from Striping and the data availability and integrity that comes from Mirroring. 1.2. Package Contents Low Profile Ultra ATA-133 RAID PCI Host Adapter This Users Manual CD (includes RAID driver, Meldey GUI software and pdf file of 48pages manual that all under directory /ATA133 RAID) Regular Size PCI Bracket 2. What Is RAID RAID - Redundant Array of Independent Disks RAID technology manages multiple disk drives to enhance I/O performance and provide redundancy in order to withstand the failure of any individual member, without loss of - 3 -

data. This card provides two RAID Set types, Striped (RAID 0), Mirrored (RAID 1) and Mirrored-Striping (RAID 0+1). Disk Striping (RAID 0) Striping is a performance-oriented, non-redundant data mapping technique. While Striping is discussed as a RAID Set type, it is actually does not provide fault tolerance. With modern SATA bus mastering technology, multiple I/O operations can be done in parallel, enhancing performance. Striping arrays use multiple disks to form a larger virtual disk. Disk Mirroring (RAID 1) Disk mirroring creates an identical twin for a selected disk by having the data simultaneously written to two disks. This redundancy provides instantaneous protection from a single disk failure. If a read failure occurs on one drive, the system reads the data from the other drive. Mirrored-Striping (RAID 0+1 also known as RAID 10) A Mirrored-Striping Set does just what it says, combining both Striping and Mirroring technologies to provide both the performance enhancements that come from Striping and the data availability and integrity that comes from Mirroring. When data is written to a Mirrored-Striped Set, instead of creating just one virtual disk as Striping would do, a second, Mirrored virtual disk is created as well. 3. RAID Setting (BIOS Setting) Creating and deleting RAID sets is a function found in the BIOS. During boot up, the RAID setting message will appear and pause for a few moments to allow the user to choose what to do. This board will act as normal NON-RAID card when BIOS not configured for RAID. Just proceed to Software Installation section directly. 3.1. Creating Striped Sets (RAID 0) 1. As the BIOS boots, press F3 to enter the raid bios utility. 2. Select Create RAID set. Press F2. 3. Select Create Striped Set press F1. - 4 -

4. Select Auto config. Press A. 5. Press 2 and then press Y to ESC exit the setup. 6. Continue with conventional Fdisk and Format steps as if you are installing a conventional hard drive. 7. Your RAID configuration is complete. Please proceed to software installation section. 3.2. Creating Mirrored Sets (RAID 1) 1. As the BIOS boots, press F3 to enter the raid bios utility. 2. Select Create RAID set. Press F2. 3. Select Create Mirrored set press F2. 4. Press Y Select automatic Setup. 5. Press Y and then press ESC to exit the setup. 6. Continue with conventional Fdisk and Format steps as if you are installing a conventional hard drive. 7.Your RAID configuration is complete. Please proceed to software installation section. 3.3. Creating a Mirrored-Striped Set 1. As the BIOS boots, press F3 to enter the raid bios utility. 2. Select Create RAID set. Press F2. 3. Select Mirrored-Striped set then press F3. 4. Select Auto config. Press A. 5. Press Y and then press ESC to exit the setup. 6. Continue with conventional Fdisk and Format steps as if you are installing a conventional hard drive. 7.Your RAID configuration is complete. Please proceed to software installation section. 3.4. Deleting RAID Sets 1. As the BIOS boots, Press F3 to enter the raid bios utility. - 5 -

2. Select Delete RAID set. Press F1. 3. Select 1 click Y to remove the RAID set. If the RAID set being deleted is a Striped set, then all of the data will be lost. If the set being deleted is a Mirrored set, then the data will remain intact and accessible on both drives. 3.5. Creating a Spare Drive After configuring a Mirrored set, it may be desirable to assign a third drive as a Spare which can automatically replace a failed drive. 1. As the BIOS boots, Press F3 to enter the raid bios utility. 2. Select Creating a Spare Drive. Press F1. 3. Choose the drive number of the drive to be designated as a spare. 4. Answer Y and the spare drive will be created and listed as the last Set. 3.6. Deleting a Spare Drive To delete a spare drive, use the same procedure as deleting a RAID set. 3.7. Resolving Conflict When a RAID set is created, the metadata written to the disk includes drive connection information (Primary and Secondary). If, after a disk failure, the replacement disk was previously part of a RAID set (or used in another system), it may have conflicting metadata, specifically in reference to the drive connection information. If so, this will prohibit the RAID set from being either created or rebuilt, in order for the RAID set to function properly, this old metadata must be first overwritten with the new metadata. To resolve this, select Resolve Conflicts, and the correct metadata, including the correct drive connection information, will be written to the replacement disk. 4. Installing Drivers And Medley GUI Software - 6 -

Windows 2000 Operating System After the board has been properly installed, when the computer is powered on, the OS will automatically search for new devices. When the new board is found, a window will appear asking Found New Hardware Wizard. Click Next, and Select search for a suitable driver for my device [recommend] click next, select specify a location click next, Insert the floppy disk into the floppy disk drive and click Browse. Most floppy disk drives are configured as [A:]. Choose the [A:] drive in your browser and the PnP680r.sys file for the SiI 0680 or PnP649r.sys file for the SiI 0649 should appear. Select the file and click Open: Verify that the directly listed in this window is A: and click OK then click next. Now, a window verifying that the new Driver for the board has been properly installed. Click Finish. To install Medley, use Windows InstallShield by performing the following: 1. After computer restarts, insert floppy disk in floppy disk drive. 2. Double-click on My Computer. 3. Double-click on 3 1/2 Floppy [A:]. 4. Double-click on Install SiIConfig.exe. 5. Follow on-screen instructions to complete installation. Note: Do NOT install in the Start Up folder. Choose the Default folder (normally Accessories or Administrative Tools or something similar). Windows NT Operating System Windows NT does not have an automatic Find Device setting and so after the operating system boots, click on the Start button located at the bottom left hand corner of the Desktop, select Settings and then Control Panel. Find and click on the SCSI Adapters. Click Drivers and Add. The next window is asking for the location of the driver to be installed. Since the driver is on the provided floppy disk, insert the floppy in the floppy disk drive and click Have Disk. The next window is asking for the location of the driver. Most floppy disk drives are configured as [A:]. To verify, click on Browse. - 7 -

The next window verifies that the appropriate file is located on [A:]. Select the file sil680r and click Open. [A:] should appear in the window. Click OK. The next window allows you to select which driver to install. Only one driver should appear in this window. Select Silion Image Sil 0680 Ultra-133 Medley ATA Raid Controller and click on OK. It is always good to Restart the computer after an installation. To install the Medley GUI, use Windows InstallShield by performing the following: 1. After computer restarts, insert floppy disk in floppy disk drive. 2. Double-click on My Computer. 3. Double-click on 3 1/2 Floppy [A:]. 4. Double-click on InstallSiIConfig.exe. 5. Follow on-screen instructions to complete installation. Note: Do NOT install Medley in the Start Up folder. Choose the Default folder (normally Accessories or Administrative Tools or something similar). Windows 98/Me Operating System With the board newly installed, as Windows 98/Me boots, the New Device will be detected and the Add New Hardware Wizard window will appear. Follow the instructions in each window, using the driver installation files (PnP680r.mpd or PnP649r.mpd) on the provided floppy disk as necessary. 1. Select specify the location of the driver [Advanced] click next. 2. Select search for the best driver for your device [Recommend]. Specify a location. Insert floppy disk into the floppy disk drive and click Browse. 3. Choose A: click ok and then next. 4. Click next and then Finish. To install the Medley GUI, use Windows InstallShield by performing the following: 1. After computer restarts, insert floppy disk in floppy disk drive. 2. Double-click on My Computer. 3. Double-click on 3 1/2 Floppy [A:]. 4. Double-click on InstallSiIConfig.exe. 5. Follow on-screen instructions to complete installation. Note: Do NOT install in the Start Up folder. Choose the Default folder (normally Accessories or Administrative Tools or - 8 -

something similar). Windows XP Operating System After the board has been properly installed, when the computer is powered on, the OS will automatically search for new devices. When the new board is found, a window will appear asking Found New Hardware Wizard. Select install from a list or specific location[advanced], click Next, and select search for a suitable driver for my device [recommend] click next, select specify a location click next, insert the floppy disk into the floppy disk drive and click Browse. Most floppy disk drives are configured as [A:]. Choose the [A:] drive in your browser and the PnP680r.sys file for the SiI 0680 or PnP649r.sys file for the SiI 0649 should appear. Select the file and click Open: Verify that the directly listed in this window is A: and click OK then click next. Now, a window verifying that the new Driver for the board has been properly installed. Click Finish. To install Medley, use Windows InstallShield by performing the following: 1. After computer restarts, insert floppy disk in floppy disk drive. 2. Double-click on My Computer. 3. Double-click on 3 1/2 Floppy [A:]. 4. Double-click on Install SiIConfig.exe. 5. Follow on-screen instructions to complete installation. Note: Do NOT install in the Start Up folder. Choose the Default folder (normally Accessories or Administrative Tools or something similar). - 9 -

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. - 10 -