Universal Design Recommendations for Accessible University Settings. Mauricio A. Lizama, Ph.D., ATP



Similar documents
Bath Planning Guidelines With Access Standards

Base Cabinet with Self-storing Folding Doors and Floor

UNIVERSAL DESIGN CHECKLIST

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations

REQUIREMENT 3. Usable Doors

604 Water Closets and Toilet Compartments

Common ADA Errors and Omissions in New Construction and Alterations

Common ADA Errors and Omissions in New Construction and Alterations

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

ACCESS AUDIT OF WESTPORT HOUSE

Chapter Seven: REQUIREMENT 7. Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms

Schedule of Maintenance Fees

PUBLIC RESTROOMS, DESIGN INTENT

The replacement or modification of existing windows shall comply with the following requirements:

Welcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S.

ADA Design Guide Washrooms & Showers

ADA. Checklist for Readily Achievable Barrier Removal. The Americans with Disabilities Act. Checklist for Existing Facilities version 2.1.

Expanding Your Market

Kitchen Planning Guidelines With Access Standards

Walking and Working Surface Checklist:

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

ADA Guide for Small Businesses

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

BUILDING PERMIT SPECIFICATIONS

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Accessible Toilets. A unisex facility should have its own entrance. It should not be entered from a single sex facility.

Hotel Accessibility Pack

CHECKLIST C ACCESSIBLE TOILETS CHECKLIST

ACCESSIBILITY STANDARD

All Apartments River Village Community Bedroom Bathroom Kitchen Living Room Commons/Hallways/Stairwells Doors Windows

Damage Charge Lists. FLOORING Replace Repair Carpet per square foot (Mohwak heat carpet tile)

Hotel Accessibility Pack

THE CENTER FOR UNIVERSAL DESIGN NC STATE UNIVERSITY College of Design. Residential Rehabilitation, Remodeling and Universal Design

Typical storey plan with two toilet clusters SANITARY PROVISION SANITARY PROVISION. Individual washroom. Standalone, unisex individual washroom

ADA Checklist for Polling Places

Accessible Single Occupancy Toilet Rooms Floor Plan Examples

Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards

Accessibility Design Advice

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

New York City Department of Buildings

Irvinton Village Apartments 2901 Fulton Houston, Texas Houston Housing Authority J. Allen Management Managing Agent

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

HOME SAFETY ASSESSMENT CHECKLIST

Droveway ARCHITECTURAL SERVICES. Disability Access Audit. Sample Gospel Hall. 22 September For

Policy Name: Accessible Customer Service Plan. Form # Position Responsible: VP Accreditation & Professional Development

accessibility standard

DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS

City of Los Angeles Department of Building and Safety Disabled Access Section COMMERCIAL ACCESSIBILITY PLAN REVIEW LIST JOB ADDRESS CITY ZIP

Inspection Item COMMENTS

ADA ACCESSIBILITY CHECKLIST FOR EXISTING FACILITIES

1 STAR HOTELS. Caballero Errante Europa Ibis Budget Madrid Vallecas Ibis Madrid Valentín Beato Sancho

Rapid Repairs Value Price List

2015 Maintenance Tenant Charge Schedule

NEW YORK. Downloaded

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

The ADL Spa. Making daily living safer and more comfortable

ACCESSIBLE SCHOOL FACILITIES A RESOURCE FOR PLANNING

SOUTH GLOUCESTERSHIRE COUNCIL SPECIFICATION REQUIREMENTS FOR WHEELCHAIR UNITS - DRAFT

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Your Basement Remodeling Specialist LLC

Ministry of the Environment Decree on accessible building

220.5" Basic Features. Electrical Features

APPENDIX B DESIGNING DISABILITY-FRIENDLY SPACES

Accessibility Guide for Small Businesses

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

Building Condition Assessment Report

3. Tile used in the toilets is generally in good shape, though somewhat dated looking. The floor tile is slippery when wet.

Mobile Home Pre-Inspection Checklist

Customer Access 1 Checklist for Banks, Financial and Legal Services

Installation Instructions

Technical Bulletin: Understanding the ADA and Implications for Office Design

City of Riverside Building & Safety Division Phone: (951)

Moving and Handling Techniques

ELECTRONIC HEALTH RECORDS AND WRITING SURFACES

Typical Finished Basement Details

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

47 Levencourt Way London SW8 1HR. Tenant: Eric Stevenson Prepared for: Elizabeth Collins

ADA HOTEL SITE INSPECTION CHECKLIST

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

17,280 square feet Overview:

The emergency provisions affect the following Building Code sections:

Wheelchair homes design guidelines. Guidelines to achieve the necessary standards for wheelchair users dwellings

BUILDING REGULATIONS PART M 2004 ACCESS TO AND USE OF BUILDINGS. Designers Checklist of Provisions/Areas for Consideration.

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

PEOPLE FIRST. How to Plan Events Everyone Can Attend. Braille Accessible Print Assistive Listening Systems

Storage Solutions. Maximize Storage & Optimize Space

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

New College. School Of Divinity.

Page 1 of 5. Exterior Finish. 1.) 8 textured lap siding. Roofing. 1.) 30-year dimensional shingles over a layer of 30# felt. Color is Weathered Wood.

Transcription:

INFORME TÉCNICO Unidad de Diseño, Desarrollo y Evaluación de AT PRATP Septiembre, 2009 Universal Design Recommendations for Accessible University Settings Mauricio A. Lizama, Ph.D., ATP The features listed here are called universal design or lifetime design features. Universal design accommodates varying needs throughout a person's life. These features are safe and easy for all persons to operate and maintain. Listed features include important factors that must be considered at the design stage and other recommendations which do not need to be addressed until the occupancy stage. However, we include all (structural and non-structural) recommendations in order to provide a clear view of the desired goal: accessibility and usability for all. General Features throughout the Campus Doorways should be at least 32 inches wide (have a 32-inch clear passage), preferably 36 inches wide. Clear floor space (18 minimum) beside door on pull side at latch jamb provides space to move out of the way of the door swing when pulling it open. 5 lbs maximum pull or push weight for opening doors. Hallways at least 42 inches wide (preferably 48 inches wide). Turning space in all rooms (at least 60 diameter). An open plan design, minimizing hallways and doorways and maximizing sight lines. Telephones accessible to a person who is unable to stand. Text telephones accessible for the deaf. There should be good, even lighting throughout the building. Light fixtures, lamps, and window treatments should be selected and placed to avoid glare on smooth surfaces. Smoke detectors with light and sound located throughout the building. Flooring materials should be hard (anti-slip), even surfaces or tightly woven, low pile carpeting over a thin pad. Color contrast between floor surfaces and trim allows easy recognition of the junction of floor surfaces and walls. Avoid glossy surfaces. Appropriate alternate access routes at reasonable distance from regular entrance area. Accessible emergency call systems. Elevators/lifters requiring key access must have clear signage indicating where such key is available or a call button to the place where the keys are held o Access to needed keys should be easy, fast and close-by. PRATP Page 1

Small garden or synthetic grass bathroom area for assistant dogs. Switches, Outlets and Controls Light switches should be located within easy reach at the entrance of each room and should be reachable from a seated position (42 to 48 inches from the floor). 54 maximum side reach, 48 maximum front reach. Electrical outlets at 18 minimum height, allows for easy reach from a sitting position as well as for those who have trouble bending over. Install outlets in enough locations to eliminate the need for extension cords (which may interfere with wheelchair use and become a danger to blind persons). Easy-touch rocker or motion activated switches. Install one electric outlet over each entrance door (on the inside part of the room) for future installation of automatic door opener. Provide an electrical outlet beside each sliding door for future installation of automatic door opener. Provide electrical outlet adjacent to each toilet (preferably below water tank level) for future installation of motion sensing auto-flush or automatic toileting system. Install lighted rocker switches outside each closet in which lighting is required or use door activated switches. Electrical panel with top no more than 54 above floor located with a minimum 30 x 40 clear floor space in front. Entrances Most entrances should be usable without going up or down steps. In many cases a ramp may be needed with a pitch of no greater than 1 to 12 (for every 1 foot in rise, 12 feet in length) and preferably 1 to 20. Entryways should be protected from rain. The entrance between the garage/parking and the building should not require going up steps. Drop-off areas protected from rain (to load/unload a wheelchair ramp) Thresholds should be level or beveled and no more than 1 2 inch higher than the floor. The doorway should have a clear, unobstructed opening at least 32 inches in width and preferably 36 inches wide. Doors should have a handle that can be reached by a seated person. If a lock is required, it should also be reached by a seated person. Space at entry doors should be a minimum 5 x 5 level clear space inside and outside of entry door for maneuvering while opening or closing door. (Can be smaller if automatic power door is provided.) Good lighting at entry doors: focused light on lockset and/or motion detector controls that turn on lights when someone approaches the door. Room numbers and office signs should be large, high contrast, well lit located in a prominent place, easy to locate. Signs should also be available in Braille and/or raised texture. PRATP Page 2

Windows/Sliding Doors Sills of windows should be no higher than 30 inches so that a person seated can see outside. Windows should be easy to open (crank operated windows are desirable). Escape windows that could be easily opened during an emergency. Sliding doors: drop frame and threshold into sub floor to reduce upstanding threshold track. Interior pocket doors: When fully open, door should extend 2 minimum outside door jamb and be equipped with open-loop handles for easy gripping. Classroom/Science labs Wheelchair accessible desks with 29 minimum clear knee space. Preferred seating (usually at the front) for low vision and hard of hearing students. Counter heights of 30, 32, and 34 inches are accessible for a seated person. The usual height for a wheelchair armrest is 29 inches. Adequate knee space requires at least 24 inches. Adjustable height work surfaces (28-42 ) allow functionality for people of all heights, those with back trouble and people who are seated. o Dual Height Counter: Includes lowered counter segments to provide work areas for seated people. Each lowered segment must have clear knee space below. Clear vertical space of 30 inches at the front of the counter will provide enough clearance for most wheelchairs. o Manually Adjustable Segments: Mechanically adjustable counter segments adjustable in 2 increments (28-42 ). A design of this type allows counter height to be adjusted with minimal work. An "adaptable design" approach such as this is ideal for a lab where users may change relatively frequently. This can be accomplished in a couple of ways: Wall mounted brackets: Counters may be mounted with heavy duty commercial shelf brackets and standards. Shelving of this type is found in many retail store shelving units. Movable wood support: A wooden support strip can be attached to the sides of base cabinets and the countertop to allow for some adjustability. o Electrically Adjustable Height: Electrically powered, continuously adjustable counter segments. This option provides a uniquely flexible, highly accessible solution. o Pull-out work surfaces: Provide a variety of work heights for different jobs. They work best when at a height of 27, and at least 30" wide by 24" deep. Space between face of cabinets and opposite walls should be 48 minimum. Clear knee space under counter (29 high minimum). May be open knee space or achieved by means of removable base cabinets or fold-back, bi-fold, or self-storing doors. Pipe protection panels must be provided to prevent contact with hot or sharp surfaces Color contrasts at the front and back edges of counter tops serve as visual cues to persons with impaired vision. Use contrasting colors on counter edges to increase visibility for those with visual impairments. Light-colored counter tops reflect available light and are desirable for persons with limited vision. PRATP Page 3

Round corners on all countertops, especially for visually impaired persons Stretches of continuous counter tops for easy sliding of items to different areas (facilitate task flow) Full-extension, pull-out drawers, shelves and racks for easy access to all storage space. Adjustable height shelves in wall cabinets. Whenever possible, use front or side mounted controls on equipment to facilitate easy reach. Equipment dials 1½ inches or greater in diameter are easier to turn. Controls should have readable settings and directions with large print and good contrast. If possible, mount controls and faucets on the side of the sink rather than the back. They are easier for seated persons to reach. Use sprayer with a flexible hose. Cabinet doors and drawers should be easy to open. D-shaped handles or magnetic closures are easier to use. Storage that includes pullout shelves, baskets, and lazy susans makes items more accessible. Below a counter, base cabinets with no shelves can be used by a seated person when the cabinet doors are open. Adequate glare-free task lighting is needed throughout the lab. Ensure fire extinguisher is within easy reach and is usable by persons with impaired mobility and dexterity. Bathrooms Bathroom doors should be at least 32 inches wide and open out (or both ways) so that if a person falls in the bathroom, they do not block the door. Adequate maneuvering space: 60 diameter turning space in the room and 30 x 48 clear floor spaces at each fixture. Spaces may overlap. Clear space (36 ) in front and to one side of toilet allows for easy maneuvering at toilet. Toilet centered 18 from any side wall, cabinet or tub. Lavatory counter height (32 minimum, 34 maximum). Knee space under lavatory (29 high) allows someone to use lavatory from a seated position. Pipe protection must be provided to prevent contact with hot or sharp surfaces. Countertop lavatories preferred with 6½ deep bowl mounted as close to front edge as possible. Wall hung lavatories acceptable with appropriate pipe protection. Pedestal lavatories are not acceptable. Long mirrors should be placed with bottom no more than 36 above finished floor and top at least 72 high. Full-length mirrors are good choices. Tilted mirrors may be used. Provide adequate space and anchoring surface for installation of grab bars. Grab bars should be considered a safety feature to prevent falls. Grab bars should be able to support 250 pounds. Towel bars are not safe to be used as grab bars. Non-slip surfaces and flooring in the bathroom helps prevent falls. Single-lever water controls at all plumbing fixtures and faucets. Handles on faucets should have levers rather than knobs for easier use. Showers (e.g. sports complex) PRATP Page 4

Stairs Other Hand-held showers in all tubs and showers, in addition to fixed heads, if provided. Single lever diverter valves are preferred. Adjustable height, movable hand-held shower head or 60 flexible hose allows easy use by people of all heights. Mixer valve with pressure balancing and hot water limiter prevents scalding people who cannot move out of the way if water temperature and/or pressure changes suddenly. Curb less shower (minimum 5 x 3, 5 x 4 preferred), waterproof floor, and a floor drain. Integral transfer seat in shower stall allows people to sit in the shower without needing additional equipment. Water controls and faucets are sometimes easier to reach if they are located off center, near the entry side of the shower. Offset controls with adjacent clear floor space allows for easy access from outside the shower with no inconvenience when inside. Step height (risers) should be no greater than 7 inches high (preferably 6 inches, minimum of 4inches) Steps should be 11 inches deep to fit most shoe sizes. All stairs should have appropriate width and space at the bottom for later installation of a platform lift, if needed. Stair handrails to extend horizontally beyond top and bottom risers. Light switches should be located at both the top and bottom of the stairs, and the stairway should be adequately lit. Color contrast difference between treads and risers on stairs. Easy to use hardware, requiring little or no strength or flexibility: lever door handles push plates loop handle pulls on drawers and cabinet doors touch latches magnetic latches in lieu of mechanical, keyless locks Clear policies to handle special or emergency situations such as heavy rain, flooded areas, strong wind, electric failure, fire, etc. Map of accessible campus routes, including slopes (if appropriate). PRATP Page 5