R E P O R T N U M B E R QI1208164



Similar documents
Unmatched Metal Hardness Testing

TotTurf Interlocking Tile TotTurf Interlocking Tile Product Specifications TOTTURF a PLAYCORE company August 2012

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

SECTION PLAYGROUND SURFACING TILES

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

EXPERIMENT 10 CONSTANT HEAD METHOD

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: VL-WDW11 VistaLuxe Awning

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

SEALED BID SOLICITATION QUOTATION BLANKET ORDER

METHOD OF TEST FOR UNIT WEIGHT OF FRESH CONCRETE

High Strain Dynamic Load Testing of Drilled Shafts

TEST REPORT. Rendered to: DEXERDRY. For: Deck Weatherproofing System Installed with AZEK Deck Boards

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

Government of Nova Scotia. Standards for the Daily Program (revised October 2012)

Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less

Name: PLSOIL 105 & 106 First Hour Exam February 27, Part A. Place answers on bubble sheet. 2 pts. each.

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

Chapter 3 Pre-Installation, Foundations and Piers

Technical Services. Product MM INCH Installation direction Seams treatment GTI CONNECT (interlocking)

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

home site map help ECMS Project: Standard / Federal Oversight Advertised

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Caltrans Geotechnical Manual

Moisture and Resilient Floor Covering

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

TEST REPORT. Rendered to: BRISTOLITE SKYLIGHTS Santa Ana, California

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: T TYPE: Two-Lite Storefront

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Analytical Testing Services Commercial Price List ManTech International Corporation January 2016

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania

Roof Inspection and Evaluation

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

APPENDIX C MOISTURE GUIDELINES & MOISTURE TESTING

AIRCRAFT PERFORMANCE Pressure Altitude And Density Altitude

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

TEST PROCEDURE FOR FIELD WITHDRAWAL RESISTANCE TESTING

PERFORMANCE TEST REPORT. Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall

SECTION 311 PLACEMENT AND CONSTRUCTION OF CEMENT TREATED SUBGRADESOIL CEMENT BASE COURSE

TEST REPORT. Report No.: B Rendered to: CROFT, LLC. Magnolia, Mississippi. PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95

How To Test Water Penetration On Concrete Block And Mortar

REQUIREMENTS FOR OBTAINING A THORNBURY TOWNSHIP, DELAWARE COUNTY PERMIT

Phoenix Body Fat Scale Manual

C. Section TESTING LABORATORY SERVICE.

Low risk includes facilities that sell or give away non potentially hazardous food in original manufacturer packaging and do not offer samples.

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR1 Teutonic Outswing Vinyl Entrance Door

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR2 Teutonic Outswing Vinyl Entrance Door

Principle #4 - Monitoring

The regulations that impact outdoor space, surfacing, fall zones, equipment, entrapments, hazards and supervision are:

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

DC RESISTANCE TEST AND WEIGHT MEASUREMENT TEST ON PRAGUE ACCC/TW CONDUCTOR STRANDED BY PT KMI WIRE AND CABLE Tbk COMPANY

Appendix D.1. Testing Requirements for Infiltration, Bioretention and Sand Filter Subsoils

SUPPLIER QUALITY MANAGEMENT SYSTEM QUESTIONNAIRE

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

ACL 395 Resistivity Meter

AST M F /GSA TS01 T EST R EPO R T. Rendered to: UNI T E D ST A T ES A L U M INU M

Colorado State University. Durrell Center Roof Repair

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

FAAC International, Inc.

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

Guide for SOLID CONCRETE BLOCK SEALS

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

PRODUCT DATASHEET. Confidex Ironside Micro CONTENTS

The minimum reinforcement for the stem wall is the placement of:

RECOMMENDATIONS FOR REPAIR OF SPRAY POLYURETHANE FOAM (SPF) ROOF SYSTEMS DUE TO HAIL AND WIND DRIVEN DAMAGE

SFxxx-S PID Test Report (Potential Induced Degradation) TUV Rheinland Japan. ARC Product Management Ver. 1

Selecting a Moisture Barrier Bag

How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Proper use of the Rebound Hammer Updated to reflect the changes to ASTM C805

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

GEOTECH ENGINEERING and TESTING

SECTION SUPPORT OF EXCAVATION

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD

Details of the instrument calibration are maintained in laboratory records.

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

APPENDIX B. EPA s Investigating, Evaluating, and Remediating Moisture and Mold Problems (see EPA website for complete details)

Renovating Your Basement

Site Development Information Worksheet for single family residential development

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MGM INDUSTRIES SERIES/MODEL: TYPE: Single Hung Window

NORSOK STANDARD M-650 Edition 4. Qualification of manufacturers of special materials

RGC-IR Remote Gas Calibrator for IR400

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

Transcription:

R E P O R T N U M B E R QI1208164 PREPARED FOR RUBBER-CAL INC. 3012 S. CRODDY WAY SANTA ANA, CA 92704 ATTENTION LUIS MACIAS REPORT DATE AUGUST 8, 2012 TÜV SÜD America, Inc. 47523 Clipper Street Plymouth, Michigan 48170 USA Phone: 734.455.4841 Fax: 734.455.6590 www.tuvamerica.com TÜV SÜD America, Inc. letters, reports and data are for the exclusive use of our customers to whom they are addressed and shall not be reproduced, except in full, without the written approval of the Laboratory. Our letters and reports apply only to those samples tested, and are not necessarily indicative of the qualities of apparent identical or similar products. Samples not destroyed in testing are retained for a maximum of thirty (30) days. The use of the name TÜV SÜD America, Inc. or its Seal or Insignia, are not permitted to be used by the customer on their communications, brochures, advertising, reports or other forms of media, without prior written approval. Reported test parameters are generally specified as set points of testing equipment. All documentation and data utilized in the generation of this report are available upon request.

REPORTED / APPROVED BY: TÜV SÜD America, Inc. Reported by: Timothy Lockstein, Project Coordinator CERTIFICATION TEST PROGRAMS Approved by: Keith Shelton, Certification Manager CERTIFICATION TEST PROGRAMS Page 2 of 7

PURPOSE The purpose of this test report is to present the test results obtained during the performance of a test program. This report includes a brief description of the samples presented for test, a list of the documents presented as test instructions, and a summary of the testing performed and the results obtained. Applicable requirements and conclusions are based on the criteria provided by our client, or as specified in the reference document(s). WORK REQUESTED / REFERENCE DOCUMENT(s) ASTM F1292-09 Impact Attenuation of Surfacing Materials within the Use Zone of Playground Equipment. TEST SEQUENCE Testing was performed on August 6, 2012 and August 7, 2012. SAMPLE DESCRIPTION Rubber-Cal Inc, submitted nine (9) rubber tiles 2.5 inches thick identified as Rubber Safety Surfacing Tile. Page 3 of 7

TESTING PERFORMED IMPACT ATTENUATION Procedure Sample material was submitted for testing. A 2.5-inch thick sample: 18 x 18, was tested to determine the maximum critical fall height of the product at temperatures -6⁰C, 23⁰C, and 49⁰C. An impact test consists of three (3) impacts at the same impact site, at each temperature and height. Calculate the average HIC and G-max values using the second and third impact data. Requirements ASTM F1292-09, using an average of the last two (2) of three (3) impacts, no value shall exceed 200 G-max or 1000 HIC. Conclusion The Rubber Safety Surfacing Tiles met the requirements of ASTM F1292-09, at 6 feet. SAMPLE DISPOSITION The samples material will be retained by TÜV SÜD America for fifteen (15) days then disposed of at the discretion of TÜV SÜD America unless otherwise requested. Page 4 of 7

TEST EQUIPMENT TÜV SÜD America, Inc. s calibration system meets the requirements of ISO 17025:2005. TÜV ID Description Manufacturer Model Calibration Due System 2 Surface Impact Tester Alpha Automation Triax 2000 Verified prior to use PLYP00036 Tri-axial accelerometer Dytran 3014M2 03/13 PLYP00052 Reference Pad Alpha Automation N/A NCR PLYP00082 Hemispherical Missile Alpha Automation Per figure 1 01/14 PLYP00065 Micro P Display Unimeasure MR-0-JR-2MV13 01/13 PLYP00066 Pancake Load Cell Sensotec BL114DL30A 01/13 PLYP00068 Digital Thermometer Omega HHII 01/13 PLYP00084 Penetration Probe Omega 88311 01/13 PLYP00080 Measurement Rod Surveyors 1 10/12 PLYP00069 Environmental Chamber Russels RB-8-1-1 08/12 PLYP00101 Environmental Chamber Thermotron F-40-CHV-LN2 08/12 PLYP00071 Thermohygrometer Extech Instruments 445702 01/13 NCR No Calibration Required APPENDICES: Appendix A: Test Data Page 5 of 7

Phone: Commercial Name of product: Date of Manufacture: No. of samples submitted: Surfacing Material Report ASTM F1292-09 Client: Manufacturer: Manufacturing Location: 3012 South Croddy Way Santa Ana, CA 92704 Initial Test 800.370.9152 Follow up Test Ref Job: Rubber Safety Surfacing Tile Unknown Sample Receipt Date: 7/30/2012 Ambient Air Temperature: 21.8 C 9 samples Humidity: 36.0% Triax System 1: Triax System 2: Test Equipment: Accelerometer ID: PLYP00089 Accelerometer Calibration Due Date: TUV Report No.: QI1208164 Report Date: 8/8/2012 Test Date: 8/6/12 & 8/7/12 PLYP00101 7/31/12 PLYP00069 6/1/2012 Calibration Due Date: 7/31/12 Loose fill Material Sample Description: Environmental Chamber No.: Calibration Due Date: Environmental Chamber No.: Engineered Wood Fiber: Loose Fill Wood Rubber: Sand: Gravel: Other: Un-compacted Depth: Compacted Depth: Inches Inches Comments: Unitary Sample Description: Tiles Poured in Place Other Total Thickness: Top Layer: N/A Base Layer: N/A 2.5 The above described sample was tested at : 6 Ft. The results reported herein reflect the performance of the above described samples at the time of testing and at the temperature(s) reported. The results are specific to the described samples. Samples of surfacing materials that do not closely match the described samples will perform differently. The following data sheet provides an accurate representation of the test results. Compliance with this Standard does not constitute product certification. Sample in compliance with ASTM F1292-09 at the temperature and rating specified? Yes No Page 6 of 7 Appendix A

Client: TUV Report No. QI1208164 Manufacturer: Test Date: 8/6/12 & 8/7/12 Drop Specified Impact Height (Ft.) Reference Temperature -6 C, (21.2 F) Reference Temperature 23 C,(73.4 F) Reference Temperature 49 C,(120.2 F) G-Max HIC Velocity (ft/s) G-Max HIC Velocity (ft/s) G-Max HIC Velocity (ft/s) 1 6 158 892 19.6 153 843 19.7 162 973 19.6 2 6 158 897 19.7 155 870 19.7 166 988 19.7 3 6 156 879 19.7 161 896 19.7 158 891 19.7 Average Measured Surface Temperature Sample Condition: 157 888 158 883 162 939.5 Max. Change from reference + 3 C -6 C Max. Change from reference + 23 C 49 C,(5.4 F) 5 C,(9 F) Max. Change from reference -3 C,(-5.4 F) Drop G-Max HIC Velocity (ft/s) G-Max HIC Velocity (ft/s) G-Max HIC Velocity (ft/s) 1 7 168 1065 21.2 167 1031 21.2 171 1107 21.2 2 7 173 1123 21.2 179 1112 21.2 186 1228 21.2 3 7 176 1106 21.2 172 1065 21.3 179 1162 21.2 Average One foot over (Ft.) Reference Temperature -6 C, (21.2 F) Reference Temperature 23 C,(73.4 F) 174.5 1114.5 175.5 1088.5 182.5 1195 Max. Change from reference + 3 C Measured Surface Temperature -6 C Max. Change from reference + 23 C 49 C,(5.4 F) 5 C,(9 F) Reference Temperature 49 C,(120.2 F) Sample Condition: Max. Change from reference -3 C,(-5.4 F) Drop G-Max HIC Velocity (ft/s) G-Max HIC Velocity (ft/s) G-Max HIC Velocity (ft/s) 1 5 144 736 17.9 130 616 17.9 123 598 17.9 2 5 141 696 18.0 136 640 18.0 134 656 18.0 3 5 140 687 18.0 138 650 17.9 131 625 18.0 Average 140.5 691.5 137 645 132.5 640.5 Max. Change from reference + 3 C Measured Surface Temperature -6 C Max. Change from reference + 23 C 49 C,(5.4 F) 5 C,(9 F) Sample Condition: One foot under (Ft.) Reference Temperature -6 C, (21.2 F) Reference Temperature 23 C,(73.4 F) Reference Temperature 49 C,(120.2 F) Max. Change from reference -3 C,(-5.4 F) ÜV SÜD America, Inc. Test Report Page 7 of 7 Appendix A