LC-MS Optimierung: Eine Kombination von sowohl Hardware-, als auch Software-Weiterentwicklungen
|
|
|
- Felix Fowler
- 10 years ago
- Views:
Transcription
1 Langenauer Wasserforum 2009: Workshop Teil 1 (09:40 h - 10:05 h) Zweckverband Landeswasserversorgung Fa. Agilent [Dr. Volker Gnau] LC-MS Optimierung: Eine Kombination von sowohl Hardware-, als auch Software-Weiterentwicklungen 09. November 2009 Zweckverband Landeswasserversorgung
2 LC-MS Optimierung: Eine Kombination von sowohl Hardware-, als auch Software- Weiterentwicklungen Dr. Volker Gnau Agilent Technologies Waldbronn
3 Agenda 1. Vorstellungs der Agilent Konzepte, Ultra High Definition 2. Quantifizierung 1. direkte Injektion 2. online Solid Phase Extraction 3. Screening mit UHD-QTOF
4 Ultra High Definition Die Optimierung aller analytischen Dimensionen Signal Response Sensitivity Dynamic Range Linearity Peak Resolving Power Peak Capacity Separation Speed Mass Spectrum Data Mining Differential Profiling Annotation Ionization Profile Mass Accuracy Isotopic Fidelity Mass Resolving Power Acquisition Rate
5 Agilent 1290 Infinity LC Lowest Delay Volume Pump (w/o) mixer: 10 µl Pump, Fixed Loop 20 µl Pump, Fixed Loop, JetWeaver 55 µl Highest Precision Best Autosampler Performance ALS precision for small volumes: <1.5% from 0.5-1µLm, <0.7% from 1-2µL, 2-20 µl (40 ul) ** Pump Active Damping: RT stability < 0.2 % (1.5 min runs)** <0.002% carry-over with Chlorhexidine Optional needle seat backflushing with FlexCube Fixed Loop or Variable Loop Injections Greatest Productivity 2mL/min for highest resolution per time Reduced Ion & Matrix Suppression HT-Solution for up to 2000 samples/day (ACR) Complete Integration and control from MassHunter Enables method conversion from/to any (U)HPLC
6 Der perfekte Match - Highest Performance LC/MS Systems Agilent 1290 Infinity LC and Agilent 6540 Accurate Mass Q-TOF MS The ultimate Qual solution Agilent 1290 Infinity LC and Agilent 6460 Triple Quad MS The ultimate Quan solution
7 Methoden Entwicklung mit MassHunter Optimizer Principal workflow Setup compounds and rules Setup rules for precursor and fragment selection Setup optimization parameters Execute Optimization Creation of Acquisition Method MassHunter Optimizer is an Add-on software to MassHunter Acquisition It is used for the optimization of the compound dependant QQQ parameters (Fragmentor voltage and collision energy) Depending on the chosen rules MassHunter optimizer will make 1 to 5 individual injections for each compound All other QQQ parameters are optimized by the Autotune functionality in relation to the molecular mass over the whole mass range
8 Direkte Injektion Quantitative Analyse von Pestiziden Compounds included in method (236 compounds in Acephate Acetamiprid total) Acibenzolar-S-methyl Acrinathrin Aldicarb Aldicarb sulfone Aldicarb sulfoxide Amitraz Atrazine Avermectin B1a Azinphos-methyl Azoxystrobin Benalaxyl Bendiocarb Benfuracarb Benthiavalicarb Bifenthrin Bitertanol Boscalid Bromuconazole Bupirimate Buprofezin Butralin Cadusafos Carbaryl Carbendazim Carbofuran Carbofuran-3-hydroxy Carbophenothion Carbosulfan Chlorfenvinphos Chlorotoluron Chlorpyrifos Chlorthiophos Cinerin 1 Cinerin 2 Clofentezine Clothianidin Crufomate Cyanofenphos Cyazofamid Cyflufenamid Cyhalothrin Cymoxanil Cyproconazole Cyprodinil Cyromazine Demeton-S-methyl Demeton-S-methyl sulfone Oxydemethon methyl Dialifos Diazinon Diclobutrazol Dicrotophos Diethofencarb Difenoconazol Diflubenzuron Dimethoate Dimethomorph Dimethylvinphos(E) Dimoxystrobin Disulfoton-Sulfone Disulfoton-Sulfoxide Ditalimfos Diuron Dodine Edifenphos Emamectin B1a EPN Epoxiconazole Ethiofencarb Ethiofencarb sulfone Ethiofencarb sulfoxide Ethion Ethofumesate Ethoprophos Etofenprox Etrimfos Fenamidone Fenamiphos Fenamiphos-Sulfone Fenamiphos-Sulfoxide Fenarimol Fenazaquin Fenbuconazol Fenhexamid Fenoxycarb Fenpropimorph Fenpyroximate Fenthion Fenthion-sulfon Fenthion-Sulfoxide Fipronil Fluazifop acid Fluazifop-P-butyl Fludioxonil Flufenacet Flufenoxuron Fluopicolide Fluoxastrobin Fluquinconazole Flusilazole Flutriafol Fluvalinate Fonofos Formothion Fosthiazate Furalaxyl Furathiocarb Haloxyfop acid Heptenophos Hexaconazole Hexazinone Hexythiazox Imazalil Imidacloprid Indoxacarb Iprovalicarb Isazofos Isoprocarb Isoproturon Jasmolin 1 Jasmolin 2 Kresoxim-methyl Lenacil Linuron Lufenuron Malaoxon Malathion Mecarbam Mepanipyrim Mepronil Metalaxyl Metazachlor Metconazole Methamidophos Methidathion Methiocarb Methiocarb sulfone Methiocarb Sulfoxide Methomyl Methoxifenozide Metolachlor Metolcarb Metrafenone Metribuzin Mevinphos-1 Monocrotophos Myclobutanil Neo-Quassin Nitenpyram Nuarimol Ofurace Omethoate Oxadixyl Oxamyl Paclobutrazol Paraoxon-ethyl Paraoxon-methyl Penconazol Pencycuron Pendimethalin Phenthoate Phorate Sulfone Phorate Sulfoxide Phosalone Phosmet Phosphamidon Phoxim Picoxystrobin, Piperonyl butoxide Pirimicarb Pirimiphos-ethyl Pirimiphos-methyl Prochloraz Profenofos Prometryn Propachlor Propamocarb Propanil Propargite Propazine Propetamphos Propham Propiconazole Propoxur Propyzamide Proquinazid Prosulfocarb Pymetrozine Pyraclostrobin Pyrazophos Pyrethrin 1 Pyrethrin 2 Pyridaben Pyridaphenthion Pyrifenox Pyrimethanil Pyriproxifen Quassin Quinalphos Quinoxyfen Resmethrin Rotenone Simazine Spinosad A Spinosad D Spirodiclofen Spiromefesin Spiroxamine Sulfotep Tebuconazole Tebufenozide Tebufenpyrad Teflubenzuron Terbufos Terbufos sulfone Terbufos sulfoxide Tetrachlorvinphos Tetraconazole Tetramethrin Thiabendazole Thiacloprid Thiamethoxam Thiobencarb Thiodicarb Tolylfluanid Triadimefon Triadimenol Triazamate acid Triazophos Trichlorfon Trietazine Trifloxystrobin Triticonazole Zoxamidec
9 Methoden Entwicklung mit MassHunter Optimizer Dynamic MRM database with transitions for > 600 pesticides
10 Rt # Concurrent dmrm = x3 x4 x4 x3 x4 x2 x1 Cycle time Selection of 24 pesticide transitions from previous slide To illustrate efficiency of cycle times using dynamic MRMs.
11 # Concurrent dmrm = x3 x4 x4 x3 x4 x2 x1 Cycle time Selection of 24 pesticide transitions from previous slide To illustrate efficiency of cycle times using dynamic MRMs.
12 Quantitative Analyse von Pestiziden Chromatographic conditions Agilent 1290 Infinity LC system consisting of: HPLC method Separation column: Mobile phase: - binary pump Inj.Vol.: 1 or 10 µl - wellplate sampler - column compartment - diode array detector (not used) ZORBAX Eclipse Plus C-18 RRHD column, 150 x 2.1 mm, C, p max = 1030 bar A: 5 mm ammonium formate B: methanol + 5 mm ammonium formate Flow: 0.4 ml/min Gradient: 0.00 min 10 % B 0.50 min 10 % B 3.50 min 50 % B min 100 % B min 100 % B min 10 % B min 10 % B
13 Quantitative Analyse von Pestiziden Agilent Jet Stream conditions Spray chamber conditions: Gas temp.: 200 C Dry gas: 8 l/min Nebulizer: 30 psi Sheath gas temp: 300 C Sheath gas flow: 11 l/min Positive Negative CapVoltage: 4500 V 3000 V Nozzle voltage 300 V 0 V Automatic setup of MRM tables based on selected cycle time, retention times and retention time windows for the individual compounds Cycle time 500 ms Interscan delay 3.5 ms Total No. of MRMs 484 Maximum No. of concurrent MRMs 68 Minimum Dwell time Maximum Dwell time 3.85 ms ms
14 Quantitative Analyse von Pestiziden MRM traces of 236 pesticides in sample (10 ng/ml) Method includes 236 pesticides with 2 MRM transitions each Variable dwell times, Inter-scan delay 3.5 ms
15 Quantitative Analyse von Pestiziden - Ausschnitt MRM traces of 236 pesticides in sample (10 ng/ml) more than 120 MRM transitions in 1.2 min
16 Quantitative Analyse von Pestiziden Example 1: Cyromazine EIC for Cal_3 (1.0 pg o.c.) Quantifier: Qualifier: Peak width: 12.0 s Cycle time: 500 ms Data points: 24
17 Quantitative Analyse von Pestiziden Example 2: Linuron EIC for Cal_3 (1.0 pg o.c.) Quantifier: Qualifier: Peak width: 12.3 s Cycle time: 500 ms Data points: 25
18 Agilent 1290 Infinity LC Methode für Pestizide MRM traces of Avermectin B1a (10 ng/ml) 2x10 3 5x10 3 8x10 3 RRLC method (25 min gradient) RT Width min min 1290 method (12 min gradient) RT Width 9.70 min min 1290 method (7 min Gradient) RT Width 5.51 min min
19 Online SPE Proben Vorbereitung An Agilent solution for water analysis the AQUA system
20 Agilent AQUA Online-SPE System - Setup System configuration SPE system: Quarternary pump G1329A autosampler with 900 µl head 6 port 2 pos valve 12 port 6 pos valve 12 port stream selection valve (optional) RRLC system: Binary pump SL Well plate sampler SL (not used) Column department SL
21 Das Setup des Agilent AQUA Online-SPE Systems Method implementation in Mass Hunter Acquisition Single 900 µl injection: DRAW def. amount from sample VALVE mainpass WAIT 0.7 min / 1.5 min** REMOTE startpulse ** The delay volume of the online-spe system is approximately 100 µl. If the 900 µl seat extension is used the wait time has to be extended to 1.5 min.
22 Quantitative Bestimmung von Pestiziden MRM traces of pesticides in calibration samples w/wo SPE HPLC separation no SPE Cal_7 (1 µg/l), Inj.Vol. 20 µl HPLC separation SPE cartridge as precolumn Cal_7 (1 µg/l), Inj.Vol. 20 µl All compounds elute from cartridge under gradient conditions, increased RTs and slightly broader peaks (late eluting compounds) due to longer column. HPLC separation + SPE (backflush mode) Cal_5 (100 ng/l), Inj.Vol. 200 µl RTs similar to separation with SPE cartridge mounted as precolumn but decreased peak widths and better chromatographic resolution (result of backflush mode).
23 Quantitative Bestimmung von Pestiziden Example 1: 2-Hydroxyatrazine EIC for Cal_1 (1.0 ng/l) Quantifier: Qualifier: Peak width: 22.7 s Data points: 25 Linear range: < 1 ng/l to 1 µg/l
24 Quantitative Bestimmung von Pestiziden Example 1: 2-Hydroxyatrazine (S/N calc. peak-to-peak) 2-OH-Atrazine Water Blank 2-OH-Atrazine Test Sample 1 2-OH-Atrazine Cal 1 (1.0 ng/l) 2-OH-Atrazine Cal 2 (5.0 ng/l) 2-OH-Atrazine Test Sample 2 2-OH-Atrazine Cal 3 (10.0 ng/l) 2-OH-Atrazine Test Sample 3 2-OH-Atrazine Cal 4 (50.0 ng/l)
25 Quantitative Bestimmung von Pestiziden 20-fold injection of Cal_4 (50 ng/l, same cartridge) TIC-Overlay for 20-fold injection of Cal_4 Compound Average (in ng/l) SD RSD 2OH-Atrazine Atrazine-desisopropyl ,6-Dichlorobenzamide Metamitron Atrazine-desethyl Dimethoate Hexazinone Simazine Cyanazine Bentazone Atrazine Compound Average (in ng/l) SD RSD Isoproturon ,4-D MCPA DNOC Mechlorprop Dichlorprop Terbuthylazin Dinoseb Pendimethalin
26 Zusammenfassung Agilent LC/MS has achieved a new, higher level of performance Combined operation in MassHunter software Agilent 1290 Infinity LC allows fast, hi resolution separations Huge peak capacity for complex separations Excellent injection and RT precision Low delay volume for very fast methods Very low AS carry-over Agilent G6460 QQQ system can keep up! Fast pos/neg switching Fast MRM and Dynamic MRM methods for triple quad Dynamic MRM databases for pesticides and forensics Excellent sensitivity and linear dynamic range
27 6540 UHD Accurate Mass Q-TOF LC/MS The Highest Performing Bench-top Q-TOF - By Far Exceptional Ultra High Definition Performance With No Trade-Offs Up to 40,000 resolution Excellent isotopic fidelity Mass measurement error down to 500 ppb 5 orders of linear dynamic range Femtogram-level sensitivity with Agilent Jet Stream FAST acquisition for UHPLC up to 20 spectra/second Made Possible by Continuing Technology Breakthroughs Ion Beam Compression (IBC) cools & focuses ion beam Extended Flight Tube with Enhanced Mirror Technology (EMT) New Photonis Fast Bipolar Detector The Ultimate Qualitative Analysis System Proteomics/Metabolomics Non-targeted food/environmental screening Impurity analysis Metabolite ID
28 6540 Ultra High Definition Q-TOF Resolving Power Across the Mass Range Resolution is Scan Rate Independent 5 x R= R= R= R=30218 R= R= R= R= R= Counts vs. Mass-to-Charge (m/z)
29 6540 MS Resolution Is Invariant With Acquisition Rate - Pesticides Example Resolution azoxystrobin 404 m/z cyproconazole 292 m/z cyprodinil 226 m/z diazinon 305 m/z linuron 249 m/z paclobutrazol 294 m/z propazine 229 m/z tetraconazole 372 m/z tricyclazole 190 m/z Acquisition Rate (scans/second)
30 6540 Ultra High Definition QTOF Mass Accuracy Repetitive Injections 40pg reserpine on-column, 10 injections +ESI EIC( ) Scan Frag=240.0V Reserpine_40pgms3.d Counts vs. Acquisition Time (min) Error (ppm) Run Mean 0.25 Std. Dev 0.32 x Isotope Obs % Calc % Obs m/z Calc m/z Diff (ppm) Counts vs. Mass-to-Charge (m/z) 250 ppb mass accuracy calibration and very accurate isotopic ratios
31 Agilent MassHunter Software for Mass Spectrometry also available for GC/MS and ICP-MS in 2009 MassHunter Workstation Data Acquisition/Control Qualitative Analysis Quantitative Analysis Application Software MassHunter Profiling MS Optimizer (small mol and peptides Metabolite ID Easy Access for MassHunter MassProfiler Prof. for MassHunter
32 Pesticide Screen 1290 Infinity/6540 Q-TOF 1290/ sec analysis 250 pesticides (125pg on-column) 1-naphthol Mass [M+H] + = Resolution = ppm Peak Width=0.8 sec 23 data points Spinosad A Mass [M+H] + = Resolution = ppm Fenpyroximate E Mass [M+H] + = Resolution = ppm
33 Analysenzeit: 17 Minuten 224 Pesticides 6530 TOF/1290 Infinity UHPLC Daten-Akquisitionsrate: 3 Hz 50pg on-column
34 Analysenzeit: 3 Minuten 224 Pesticides 6530 TOF/1290 Infinity UHPLC Daten-Akquisitionsrate: 10 Hz 50pg on-column
35 Analysenzeit: 90 Sekunden 224 Pesticides 6530 TOF/1290 Infinity UHPLC Daten-Akquisitionsrate: 20 Hz 50pg on-column
36 Pesticide Screen 1290 Infinity/6540 Q-TOF Beispiel: Extrahierte Ionenchromatogramme mit unterschiedlichen Extraktionsbreiten Spinosyn A EIC ± 0.5 Da ± 0.1 Da ± 50 ppm (ca Da) ± 10 ppm (ca Da)
37 Target screening confirmation via MS/MS Beispiel: Compoundspektren für Spinosyn A Oben: MS1-Spektrum Unten: MS/MS-Spektrum, Annotationen zeigen m/z und generierte Summenformel Spinosyn A Referenzmasse
38 Target screening confirmation via MS/MS Beispiel: MS1 bzw. MS/MS-Chromatogramm für Spinosyn A mit vergleichbarem Signal/Rausch-Verhältnis Spinosyn A MS/MS EIC S/N = 96 Spinosyn A MS1 EIC S/N = 84
39 Agilent TOF Screening Solution (PCD) FBF Find by Formula
40 Non-Targeted Screen Summary (QTOF/TOF) Agilent TOF/Q-TOF for unknown screening (low ppm mass accuracy.) Agilent MassHunter PCD utilizes the accurate mass data to provide reliable positives for qualitative screens. Extra Confirmation with Isotope abundance (pattern), spacing and mass matching Pesticide analytes Fully Automated integration with MassHunter Qualitative Analysis SW. Reliable Data mining Algorithms (MFE or FBF.) Low pico-gram on-column Sensitivity. Fully Automated. Faster data acquisition with 1290 Infinity UHPLC.
Validation Data of 127 Pesticides Using a Multiresidue Method by LC-MS/MS and GC-MS/MS in Olive Oil
1 Validation Data of 127 Pesticides Using a Multiresidue Method by LC-MS/MS and GC-MS/MS in Olive Oil 3 CONTENTS 1. Aim and Scope 1 2. Short Description 1 3. Apparatus and Consumables 1 4. Chemicals 1
Fast GC-MS/MS for High Throughput Pesticides Analysis
Application Note: 52027 Fast GC-MS/MS for High Throughput Pesticides Analysis Igor Fochi, Elena Ciceri, Hans-Joachim Huebschmann, Thermo Fisher Scientific, Milan, Italy Ciro D Aniello, Laboratorio D Aniello
AppNote 4/2010. Automated QuEChERS Extraction for the Confi rmation of Pesticide Residues in Foods using LC/MS/MS KEYWORDS ABSTRACT
AppNote 4/2010 Automated QuEChERS Extraction for the Confi rmation of Pesticide Residues in Foods using LC/MS/MS Virgil Settle, Fred Foster Gerstel, Inc., 701 Digital Dr. Suite J, Linthicum, MD 21090,
LC -MS/MS: Instrumentation and settings 4 GC-MS/MS: Instrumentation and settings 5
EURL-FV Analysis of pesticide residues in fruit and vegetables with ethyl acetate extraction using gas and liquid chromatography with tandem mass spectrometric detection 0.1 1 CONTENTS 1. Introduction
Report of Pesticide Residue Monitoring Results of the Netherlands for 2001. Concerning Directive 90/642/EEC, 86/362/EEC and Recommendation 2001/42/EU
Report of Pesticide Monitoring Results of the Netherlands for 2001 Concerning Directive 90/642/EEC, 86/362/EEC and Recommendation 2001/42/EU H.A. van der Schee Inspectorate of Health Protection, Commodities
Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF
Simultaneous qualitative and quantitative analysis using the Agilent 654 Accurate-Mass Q-TOF Technical Overview Authors Pat Perkins Anabel Fandino Lester Taylor Agilent Technologies, Inc. Santa Clara,
Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
Hellenic Accreditation System S.A. Annex F1/B8 to the Certificate No 139-6
Hellenic Accreditation System S.A. Annex F1/B8 to the Certificate No 139-6 SCOPE of ACCREDITATION of the Analytical Laboratory of BIOLAB Single Member Private Company in Ioannina Tested Chemical Testing
Chemical Sub-group or Exemplifying Active Constituent. 1A Carbamates* 1B Organophosphates* 2A Cyclodiene organochlorines
1* Acetylcholinesterase inhibitors * all members of this class may not be crossresistant 2 GABA-gated chloride channel antagonists 1A Carbamates* 1B Organophosphates* 2A Cyclodiene organochlorines 2B Phenylpyrazoles
This is to signify that
This is to signify that PROFESYONEL ÇEVRE ANALIZ LAB. GIDA TARIMSAL VE KAL. HIZ. SAN. VE TIC. A.Ş TEOMANPAŞA MAH.GAZI BULVARI NO: 345 KEPEZ, ANTALYA TURKEY Testing Laboratory TL-577 has met the requirements
Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection
Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection Application Note Food Testing & Agriculture Authors Edgar Naegele and Thomas
(Text with EEA relevance)
28.6.14 L 190/55 COMMISSION IMPLEMTING REGULATION (EU) No 718/14 of 27 June 14 amending Regulation (EC) No 669/09 implementing Regulation (EC) No 882/04 of the European Parliament and of the Council as
(Text with EEA relevance)
5.12.14 L 349/33 COMMISSION IMPLEMTING REGULATION (EU) No 1295/14 of 4 December 14 amending Annex I to Regulation (EC) No 669/09 implementing Regulation (EC) No 882/04 of the European Parliament and of
JOINT FAO/IAEA DIVISION OF NUCLEAR
JOINT FAO/IAEA DIVISION OF NUCLEAR TECHNIQUES IN FOOD AND AGRICULTURE PROPOSED DRAFT REVISION OF THE LIST OF METHODS FOR PESTICIDE RESIDUE ANALYSIS INCLUDING METHODS OF DETERMINATION FOR DITHIOCARBAMATES
Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS
Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS AGILENT 6000 SERIES LC/MS SOLUTIONS UNRIVALED ACHIEVEMENT AT EVERY LEVEL The Agilent 6000 Series of LC/MS instruments
Multiresidue Analysis of Pesticides in Avocado with Agilent Bond Elut EMR Lipid by LC/MS/MS
Multiresidue Analysis of Pesticides in Avocado with Agilent Bond Elut EMR Lipid by LC/MS/MS Application Note Food Testing and Agriculture Authors Limian Zhao and Derick Lucas Agilent Technologies, Inc.
# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
[ WELCOME ] 2015 Waters Corporation 1
[ WELCOME ] 2015 Waters Corporation 1 Lance Nicolaysen Senior Director Americas Mass Spectrometry Business Waters Corporation, USA 2015 Waters Corporation 2 MS-Related Job Opportunities Field Marketing
Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay
PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird
MPLs of active substances of pesticides in food products in accordance with GN 1.2.1323-03. mg/kg
Maximum permissible levels (MPLs) of residues of active substances of pesticides in fresh food products of plant origin fixed by Russian legislation in accordance with Hygiene Standard (GN) 1.2.1323-03
Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System
Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS
How To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
list of active substances, all matrices
list of s, all matrices number of validated s according to SANCO/12571/2013 in multi residue method (MRM): 467 reporting limit (mg/kg) according to matrices* multi residue method (MRM) 2,4,5-T (F) LC-MS/MS
[AMI] Multi-residue method, by LC-MSMS, for the quantification of amitraz and its metabolites in fruit, vegetables, cereals and cereal products
Multi-residue methods: all the mentioned substances will be searched for. The general reporting limit (RL) (mg/kg) is mentioned on the right side of each pesticide. The limit of quantification may vary
IRAC Mode of Action Classification Scheme
Insecticide Resistance Action Committee www.irac-online.org IRAC Mode of Action Classification Scheme Issued, April 2016 Version 8.1 Prepared by: IRAC International MoA Working Group Approved by: IRAC
Annex of the Certificate (Page 1/6) Accreditation Scope
Annex of the Certificate (Page 1/6) Deney Laboratuvarı Accreditation Number: Address: Osman Akça Tüccarlar Sitesi Ticaret Borsası Hizmet Binası Kat:2 No:2/ALAŞEHİR 45600 MANİSA / TÜRKİYE Phone Fax E-Mail
Agilent LCMS products and the application strategies in veterinary drug analysis
Agilent LCMS products and the application strategies in veterinary drug analysis Experience A New Level of Confidence Ma Xin 马 鑫 LCMS Application Engineer Internal Sales Training - The new 6495 QQQ LC/MS
UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs
Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs
PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW
OVERVIEW Exact mass LC/MS analysis using an orthogonal acceleration time of flight (oa-tof) mass spectrometer is a well-established technique with a broad range of applications. These include elemental
The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis
The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis Stephen Lock AB SCIEX Warrington (UK) Overview A rapid, robust, sensitive and specific LC-MS/MS method has been developed for
Revista: Journal of Chromatography A Volume 1314, November 2013. Preprint de l autor. Versión / Versió:
Título artículo / Títol article: Application of gas chromatography (triple quadrupole) mass spectrometry with atmospheric pressure chemical ionization for the determination of multiclass pesticides in
IRAC Mode of Action Classification Scheme
Insecticide Resistance Action Committee www.irac-online.org IRAC Mode of Action Classification Scheme Issued, May 2015 Version 7.4 Prepared by: IRAC International MoA Working Group Approved by: IRAC Executive
API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined
API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS AB SCIEX QTRAP 4500 LC/MS/MS System and Gerstel, Inc. MultiPurpose Sampler
MassHunter for Agilent GC/MS & GC/MS/MS
MassHunter for Agilent GC/MS & GC/MS/MS Next Generation Data Analysis Software Presented by : Terry Harper GC/MS Product Specialist 1 Outline of Topics Topic 1: Introduction to MassHunter Topic 2: Data
The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring
The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring Delivering up to 2500 MRM Transitions per LC Run Christie Hunter 1, Brigitte Simons 2 1 AB SCIEX,
Fast Screening, Identification, and Quantification of Pesticide Residues in Baby Food Using GC Orbitrap MS Technology
Fast Screening, Identification, and Quantification of Pesticide Residues in Baby Food Using GC Orbitrap MS Technology Cristian Cojocariu, 1 Dominic Roberts, 1 Michael T. Hetmanski, 2 Richard J. Fussell,
Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES
Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES AGILENT ENHANCED MATRIX REMOVAL LIPID ARE LIPIDS WEIGHING YOUR SAMPLES DOWN? Interference from lipids is a problem for labs measuring
Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays
Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays Scheduled MRM HR Workflow on the TripleTOF Systems Jenny Albanese, Christie Hunter AB SCIEX, USA Targeted quantitative
The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.
The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. Mark Crawford Single Presenter Name Abstract With the recent decline in hive bee populations this year the investigation of acaricides
Appendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates Using the Explore Workflow on the AB SCIEX TripleTOF 5600 System A major challenge in proteomics
Micromass LCT User s Guide
Micromass LCT User s Guide 1) Log on to MassLynx with your username & password. 2) After you have logged in, the MassLynx software will automatically run. 3) After MassLynx has come up, open your project
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
Methods of Analysis Determination of Pesticides in Sediment Using Gas Chromatography/Mass Spectrometry
Methods of Analysis Determination of Pesticides in Sediment Using Gas Chromatography/Mass Spectrometry Techniques and Methods 5 C3 U.S. Department of the Interior U.S. Geological Survey Methods of Analysis
Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column
Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column Sachiki Shimizu, FUJIFILM Fine Chemicals Co., Ltd., Kanagawa, Japan Kenneth J. Fountain, Kevin Jenkins, and Yoko Tsuda,
HONEY BEES FROM PESTICIDES
E-53-W Beekeeping Department of Entomology PROTECTING HONEY BEES FROM PESTICIDES Christian H. Krupke, Gregory Hunt and Rick E. Foster, Extension Entomologists Honey bees are a vital part of our agricultural
Bologna 12-13 Maggio 2011; 1 MS Environmental Day
; 1 MS Environmental Day E. Salvadori, A. Falai, M. Cappelli, S. Dugheri, A. Bonacchi, G. Arcangeli, V. Cupelli, D. Santianni, D. Burrini ISPRA reports: 50% of monitoring points of surface water are contaminated
Chronic dietary exposure to pesticide residues in the United States
Winter International Journal of Food Contamination (2015) 2:1 DOI 10.1186/s40550-015-0018-y DATA ARTICLE Open Access Chronic dietary exposure to pesticide residues in the United States Carl K Winter Abstract
Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France
Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS Mikaël LEVI Shimadzu France Welcome Seminar Barcelona 2013 Interest in Steroids assay by LC-MS/MS Steroids measurement is essential
Dietary intake of pesticide residues in Italy: results of 2005-2008 study
Dietary intake of pesticide residues in Italy: results of 2005-2008 study Michele Lorenzin Provincial Agency for Environmental Protection, Autonomous Province of Trento, Trento, Italy Corresponding author
High-Throughput 3-D Chromatography Through Ion Exchange SPE
High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample
Supplementary Materials and Methods (Metabolomics analysis)
Supplementary Materials and Methods (Metabolomics analysis) Metabolite extraction and mass spectrometry analysis. 12 Vldlr-/- knock out and 12 wild type (WT) retinas were separately frozen at -80 ºC in
Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS
Summary: Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS UCT Part Numbers: CUNAX226 - Clean-Up C8+NAX, 2mg/6mL BETA-GLUC- ml Beta-Glucuronidase Enzyme, liquid form SLAQ1ID21-3UM -
How To Use An Agilent 9 Infinity Lc
Agilent 9 Infinity LC Infinitely more powerful 9 Agilent 9 Infinity LC Infinitely more powerful. With more than enough power to handle any HPLC or UHPLC challenge, the advanced technology in the Agilent
Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2
Technical ote Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2 Alek. Dooley, Carmai Seto, esham Ghobarah, and Elliott B. Jones verview:
AMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application
Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform
Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform Remco Swart Pittcon March 8-12, 2015 1 The world leader in serving science Outline Thermo Scientific Vanquish UHPLC
Biocides main groups
Analytical challenges for the analysis of biocides in aqueous and solid environmental matrices Arne Wick, Kathrin Broeder, Michael Schluesener, Thomas Ternes Federal Institute of Hydrology (BfG), Koblenz,
Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening
Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Application Note Forensics Author Erin Shonsey Director of Research Alabama Department of Forensic Science Abstract
UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research
UPLC-MS/MS Analysis of in Plasma for Clinical Research Dominic Foley and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity improves reproducibility through removal
Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform
Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform Charles Yang, Leo Wang, Dipankar Ghosh, Jonathan Beck,
Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method
Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method Introduction During the last decade, the complexity of samples
LC-MS/MS Technology and Applications Transform your routine science
LC-MS/MS Technology and Applications Transform your routine science Jonathan Beck, Ph.D Marketing Scientist Environmental & Food Safety October 2th, 215 1 The world leader in serving science Outline High
Rapid and Easy Multiresidue Method for Determination of Pesticide Residues in Foods Using Gas or Liquid Chromatography Tandem Mass Spectrometry
Rapid and Easy Multiresidue Method for Determination of Pesticide Residues in Foods Using Gas or Liquid Chromatography Tandem Mass Spectrometry Satoshi Takatori, Masahiro Okihashi, Yoko Kitagawa, Naoki
Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances
Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances TripleTOF 5600 + LC/MS/MS System with MasterView Software Adrian M. Taylor AB Sciex Concord, Ontario (Canada) Overview
Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine
Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine Application Note Authors Peter JW Stone and Kevin McCann Agilent Technologies, Inc. Santa Clara,
The Bitter Taste of Europe s Apple Production and how Ecological Solutions can Bloom
of Europe s Apple June 2015 Introduction: Solutions can The Bloom Bitter Taste Solutions can Bloom Apple and fruit production is one of the most chemical intensive sectors in Europe s agriculture. Considering
List of Banned Pesticides and Pesticides Watchlist Version 1.0
List of Banned Pesticides and Pesticides Watchlist Version 1.0 www.utzcertified.org UTZ Certified Draft List of Banned Pesticides and Pesticides Watch List May 2014 0 Translations of this document are
Spices 1779. Compound Commodity Spike level mg/kg ginger root, galangal rhizome, pepper black and white pepper black and white 0.1 0.5 1.
Spices 1779 EVALUATION OF PESTICIDE RESIDUES IN SPICES First draft prepared by Prof. Dr. Arpad Ambrus, Hungarian Food Safety Office, Budapest, Hungary EXPLANATION The 2004 JMPR estimated maximum residue
Analysis of Veterinary Drug Residues in China
Analysis of Veterinary Drug Residues in China Dr. Xionghai Yi( 伊 雄 海 ) Shanghai Entry-Exit Inspection and Quarantine Bureau of The People s Republic of China SEP. 10, 2014 Contents Profile of the institution
Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System
Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System Olaf Scheibner, Maciej Bromirski, Thermo Fisher Scientific, Bremen, Germany
eco-institut-label Test criteria: Bedding goods
Test criteria: Bedding goods (Status: June 2016) A Basic requirements Full declaration of Minimisation requirements for substances with dangerous properties according to dangerous substances regulations.
Discovery of Pesticide Protomers Using Routine Ion Mobility Screening
Michael McCullagh, 1 David Eatough, 1 Vincent Hanot, 2 and Séverine Goscinny 2 1 Waters Corporation, Wilmslow, UK 2 Wetenschappelijk Instituut Volksgezondheid Institut Scientifique de Santé Publique, Brussels,
Automation of Solid Phase Extraction and Column Chromatographic Cleanup
Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for
Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract
LC-MS/MS for Chromatographers
LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,
Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract
Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate
Fairtrade International Prohibited Materials List
Fairtrade International Prohibited Materials List The Prohibited Materials List (PML) is divided in two lists: the Red List and the Amber List. Red List The Red List includes materials that must not be
High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK
High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK Background Unilabs YBS are a bioanalytical CRO based in York (Uk) Copenhagen
amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS
amazon SL Setting New Standards in Performance, Simplicity and Value Innovation with Integrity Ion Trap Best-In-Class Ion Trap Mass Spectrometer for Routine Analysis The amazon SL entry-level system is
Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis
Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines
Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection
Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection Derek Hillbeck, Thermo Fisher Scientific, Runcorn, UK Application Note 2999 Key
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification Gold Standard for Quantitative Data Processing Because of the sensitivity, selectivity, speed and throughput at which MRM assays can
Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring
PO-CON1359E Ultra Fast UHPLC-LCMSMS Method Development in HPLC 2013 MASS-09 Anja Grüning 1 ; Brigitte Richrath 1 ; Klaus Bollig 2 ; Sven Vedder 1 ; Robert Ludwig 1 1 Shimadzu Europa GmbH, Duisburg, Germany;
Outline of MassHunter Software Session
Outline of MassHunter Software Session 1. Overview MassHunter Software Programs 2. From ChemStation to MassHunter (Optional) 3. MassHunter Qual and Quant (?) 4. MassHunter for LC/MS Demo Find by Methods:
Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) Approach for Determining Pesticide Residues
In Press Pesticide Analysis in Methods in Biotechnology, Eds. J.L. Vidal Martinez and A. Garrido Frenich, Humana Press, USA Nov. 2004 6 Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) Approach
Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report
of melamine-ware by GC-MS and LC-MS/MS Page 1 of 15 Method development for analysis of formaldehyde in foodsimulant extracts of melamine-ware by GC-MS and LC-MS/MS December 2012 Contact Point: Chris Hopley
Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS
Bruker ToxScreener TM A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS ToxScreener - Get the Complete Picture Forensic laboratories are frequently required
Resistance to Pesticides. Rupert Knowles
Resistance to Pesticides Rupert Knowles Farmer Choices If a farmer has a pest problem and has been advised to apply pesticides, he has many factors to think about. List 10 factors that affect the farmer
Q-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.
Q-TOF User s Booklet Enter your username and password to login. After you login, the data acquisition program will automatically start. ~ 1 ~ This data acquisition window will come up after the program
ORSER ORGANIK URUNLER KONTROL vesertifikasyon LTD.STI Cemal Nadir Sokak No:10/5 Cankaya/ANK
ACARICIDI "A"-ACARICIDES "A"(mip 01 ed. 02 rev. 09 2008) Amitraz (including the metabolites containing the 2,4-dimethylanine moity expressed as amitraz) < L.O.D. 0,010 Binapacryl < L.O.D. 0,010 Bromocyclen