Quality documentation challenges for veterinary clinical pathology laboratories
|
|
|
- Molly Burke
- 10 years ago
- Views:
Transcription
1 J Vet Diagn Invest 20: (2008) Quality documentation challenges for veterinary clinical pathology laboratories Federico Sacchini, 1 Kathleen P. Freeman Abstract. An increasing number of veterinary laboratories worldwide have obtained or are seeking certification based on international standards, such as the International Organization for Standardization/ International Electrotechnical Commission Compliance with any certification standard or quality management system requires quality documentation, an activity that may present several unique challenges in the case of veterinary laboratories. Research specifically addressing quality documentation is conspicuously absent in the veterinary literature. This article provides an overview of the quality system documentation needed to comply with a quality management system with an emphasis on preparing written standard operating procedures specific for veterinary laboratories. In addition, the quality documentation challenges that are unique to veterinary clinical pathology laboratories are critically evaluated against the existing quality standards and discussed with respect to possible solutions and/or recommended courses of action. Documentation challenges include the establishment of quality requirements for veterinary tests, the use or modification of human analytic methods for animal samples, the limited availability of quality control materials satisfactory for veterinary clinical pathology laboratories, the limited availability of veterinary proficiency programs, and the complications in establishing species-specific reference intervals. Key words: International Organization for Standardization/International Electrotechnical Commission standards; quality documentation; standard operating procedures. Introduction Quality management systems for laboratories are designed to promote and maintain the generation of valid test results in a way that meets or exceeds client expectations. A quality management system may help to demonstrate that the laboratory is technically competent and able to produce results appropriate for its needs. In the absence of compulsory quality standards, the implementation of quality management systems in veterinary laboratories has historically been driven by the need for mutual recognition of infectious disease tests for international trade. The release of standards of acceptable laboratory practice derived from the International Organization for Standardization (ISO)/International Electrotechnical Commission (IEC) by the World Organization for Animal Health (OIE), the animal health reference institutions of the World Trade Organization, has facilitated the implementation of quality management among laboratories responsible for certifying the infectious disease status of traded animals. 8,18 In North America, the American Association of Veterinary Laboratory Diagnosticians (AAVLD) has run From IDEXX Laboratories, Wetherby, West Yorkshire, United Kingdom. 1 Corresponding Author: Federico Sacchini, IDEXX Laboratories, Grange House, Wetherby, West Yorkshire LS22 7DN, UK. [email protected] an accreditation program for publicly funded veterinary diagnostic laboratories since The AAVLD has recently incorporated the OIE quality standards into its essential requirements for accreditation. 1,18 In addition, several veterinary laboratories worldwide that are not involved in official infectious disease testing but have recently obtained or are seeking certification based on international standards, such as the ISO/IEC or the more recent ISO/IEC The recent establishment of the European College of Veterinary Clinical Pathology (ECVCP) has provided a further incentive to implement a quality management system for veterinary laboratories in Europe. In order to be considered a training laboratory for candidates for the ECVCP examination, European veterinary laboratories must be ECVCP accredited. 4 The verification of compliance with any certification standard requires complete documentation of the processes included in the quality system. In human medical laboratories, the most common deficiencies identified during on-site inspections performed by regulatory bodies are quality documentation problems. 6,12 Unsurprisingly, the inadequacy of written documentation has been reported as a major problem for several veterinary laboratories seeking approval for training by the ECVCP Laboratory Standards Committee and is likely to represent a major obstacle 266
2 Quality documentation 267 for other veterinary laboratories seeking certification based on international standards. 4 In addition to problems shared with human medical laboratories, several quality documentation issues are unique to veterinary clinical pathology laboratories. The absence of defined quality requirements, the frequent use or modification of human analytical methods, the limited availability of quality control (QC) materials satisfactory for animal species, the scarcity of proficiency testing programs specific for veterinary laboratories, and the lack of valid species-specific reference intervals are typical challenges that have to be faced during the preparation of quality documentation for veterinary clinical pathology laboratories. The main purpose of this article is to provide an overview of the documentation needed to implement a quality management system in veterinary laboratories, with an emphasis on standard operating procedures (SOPs). In addition, the quality documentation challenges that are unique to veterinary clinical pathology laboratories are critically evaluated against the existing quality standards (ISO, OIE, AAVLD) and discussed with respect to possible solutions and/ or recommended courses of action. Quality documentation in the veterinary laboratory Quality documentation can be defined as the set of documents and records generated by a laboratory to demonstrate the planning, implementation, adherence to, and continuous improvement associated with a quality management system. Documentation comprises all levels of the organization, from the quality statement and SOPs to the forms and reports medical laboratories generate daily. Additionally, many other types of internal and external documents, such as meeting minutes, reference intervals, instructions, laboratory plans, and textbooks, are considered part of the quality documentation. 8 The amount of documentation produced should be adequate to demonstrate compliance with the quality system without overburdening laboratory personnel with unnecessary documentation. A good documentcontrol system is necessary to provide unique identifiers for all documents, to assist in the periodic review of documents currently in use, and to ensure that obsolete documents are promptly removed from the environment. Specific software packages for document control are commercially available and are commonly used for the management of all the quality system documentation (IdeaGen Software: 2006, Quality workbench. Matlock, Derbyshire, UK; Clinical Pathology Accreditation [UK]: Available at: Accessed November 16, 2007). 2 The veterinary laboratory has a need for quality documentation to demonstrate quality practices as requested by ISO or other external quality certification authorities and/or to demonstrate to internal and external clients and management the activities associated with the quality system, regardless of whether or not external certification is desired. Quality documentation is derived from quality plans addressing both the laboratory environment/community and philosophy/vision. The latter addresses the scope of testing, type of clientele, quality standards, and ongoing quality improvement, while the laboratory environment/community refers to the actual physical setting of the laboratory and its facilities, equipment, and personnel. Eventually, the quality plans are translated into the working practices and procedures that make up the practical instructions that regulate the activities within the laboratory. Finally, the forms and records generated while executing laboratory activities provide evidence of quality practices as determined by the quality management system. The relationship between documentation and other quality aspects in the veterinary laboratory is shown in Fig. 1. Each of the items specified within the concept map requires documentation to provide evidence of the laboratory s commitment to quality, the competence of personnel, assurance of the quality of results, delivery to veterinary clients, and provision of the best possible patient care as a result of the laboratory-veterinarian partnership. The categories and relationships identified in Fig. 1 may be further expanded to specify the standards and working practices in each section. The expansion for the section on environment/community includes addressing such issues as the adequacy and ergonomics of facilities, the type of equipment and its validation, maintenance, calibration, and performance requirements. Training, initial and ongoing competency demonstration, and appraisal forms and plans should be included in the section for personnel. The philosophy and vision section should include information regarding the scope of testing, quality requirements for testing, the turnaround time for various tests, internal QC and proficiency testing, audits, and other aspects of continuous quality improvement. Working practices/procedures can be expanded to include the specific aspects of a variety of documents, including the laboratory catalogue, price list, information sheets or handouts, invoices, report forms, work lists, and performance logs. Standard operating procedures An SOP is a set of written instructions that describes a routine or repetitive activity an organization follows. SOPs describe the operational elements
3 268 Sacchini, Freeman Figure 1. Concept map showing the relationship between documentation and other quality aspects in the veterinary clinical pathology laboratory. of an organization and are derived from its quality policy. 8,15 The preparation and use of SOPs represent critical parts of any quality management system and are not an exclusive requirement of the ISO standards. The main purpose of SOPs is to facilitate consistent conformance to technical and quality specifications within an organization. For this reason, SOPs are intended to be specific to the organization whose activities are described. Adopting SOPs allows organizations to implement standardized processes to maximize the efficiency and effectiveness of the work effort and minimize the effects of temporary/ permanent personnel changes. In addition, SOPs can be used as educational material for personnel training programs and can serve as a checklist for inspectors during the auditing process. 8,15 It is the laboratory s responsibility to decide which of its activities need to be documented. Table 1 provides examples of quality policies and SOPs adopted by the cytology department of the authors laboratory. The writing style of the SOP should be concise, and information should be provided in a step-by-step format. The amount of information included should be sufficient to allow someone with limited experience, but basic understanding, to perform the procedure unsupervised. The minimum level of expertise required to carry out the procedure should also be specified. 2,7,8,15,18 The SOP format may vary significantly between organizations and types of SOPs being written. A laboratory should have SOPs that describe preanalytical, analytical, and postanalytical activities. A generalized format should include title, purpose or principle, procedure instructions, quality documentation management information, and additional information in the procedure instruction for analytical methods. Activities performed with automated in-
4 Quality documentation 269 Table 1. Standard operating procedures (SOPs) and policies adopted in the Cytology department of the authors laboratory.* Preanalytical elements Analytical elements Postanalytical elements SOPs Cytology specimen receipt Cytology body fluid analysis Cytology report auditing Cytology specimen test request entry Cytology smear preparation Actions for nonconformities, client complaints, and improvement opportunities in the Cytology department Cytology work load generation Cytology cytospin preparations using Cytology report authorization the Shandon Cytospin 3 Maintenance of the Hema-Tek Staining cytology slides using the Routing of specimens from Cytology Policies Automatic Slide Stainer Maintenance of the Shandon Automated Coverslipper Maintenance of the Shandon Cytospin 3 Identification and handling of potentially infectious materials in the Cytology department Handling of leaking specimens or those received in inappropriate packing Hema-Tek Automatic Slide Stainer Coverslipping slides using the Shandon Automated Coverslipper Assignment of cytology cases to pathologists Cytology reporting Reporting of urgent cytology specimens Cytology case second opinions to other departments General housekeeping in the Cytology department Retention and disposal of cytology submissions * Examples from the authors laboratory. Other laboratories within different organizations or with different preferences may have other SOPs and policies or include them in other areas of the laboratory. struments may contain the instructions from the instrument s manual and manufacturer s literature; activities performed manually need to be described in detail following the step-by-step procedures performed in the laboratory. A general template for an analytical SOP is shown in Table 2. 2,3,7 Documentation challenges in veterinary clinical pathology laboratories The previously described documentation concepts and guidelines are extrapolated from international standards developed by the ISO and the Clinical and Laboratory Standards Institute (CLSI), which are applicable to any type of diagnostic laboratory. Although the same principles can be intuitively adjusted to prepare quality documentation for many different types of laboratories, a series of specific challenges arise for veterinary clinical pathology laboratories. As previously mentioned, these include the absence of compulsory quality requirements for veterinary tests, the frequent use or modification of human analytical methods for animal samples, the limited availability of QC materials at levels of analytes significant for animal species, the limited availability of proficiency testing programs for veterinary testing, and the complications in establishing species-specific reference intervals. In the following section, the previously identified quality challenges specific to veterinary clinical pathology laboratories are critically evaluated with reference to the quality standards usually adopted (ISO/IEC 17025, ISO/IEC 15189, OIE, AVVLD) and discussed with respect to possible solutions and/or recommended courses of action. Absence of compulsory quality requirements Quality requirements are critical to quality planning. In the clinical pathology laboratory this type of information promotes selection of analytical methods based on the required specifications (e.g., allowable imprecision, inaccuracy, total error) and to implement statistical QC procedures designed to detect errors that exceed the predetermined quality requirements. 16 Quality requirements can be established in several ways, depending on the intended use of information. For instance, quality requirements for clinical pathology laboratories can be provided in the form of medically important changes (e.g., clinical decision limit, medically significant change), analytical quality requirements (e.g., allowable total error), or analytical performance criteria (e.g., maximum allowable imprecision/bias), all of which can be translated in operating specifications for the method (e.g., allowable imprecision, allowable bias, and validated QC procedures; Wesgard, JO: 2000, Defining quality requirements. Available at: westgard.com/lesson53.htm. Accessed November 17, 2007). The existence of many different types of quality requirements has created some confusion in human clinical pathology, and a hierarchic approach to quality requirements has been recently proposed to clarify the subject. 10 Veterinary clinical pathology
5 270 Sacchini, Freeman Table 2. General template for analytical standard operating procedures (SOPs). 2,3,7,8,15 Title/name Category Scope/principle of the examination Procedure instructions Summary of method performance/validation Health and safety Method limitations Equipment and reagents Quality control procedures and frequency Step-by-step procedure instructions Directions for test interpretation Document control information Comments Clearly identify the intent of the activity being described. The adopted methodology should be indicated in the title of analytical SOPs. Must be stated at the beginning of the document. May be included within the procedure instructions, even if not necessary to perform a repetitive activity: N Adoption of validated methods is an essential quality standard requirement. N Inclusion of performance specifications (e.g., linearity, sensitivity, specificity, accuracy) may help technicians understand the scope of the procedure. N Inclusion may allow the SOP to be used for training/teaching purposes. Reference general health and safety guidelines, as well as risks or preventive measures needed for the specific activity defined by the SOP. N Type of sample(s) and volume(s) acceptable for analysis N Sample handling and storage N Effects of hemolysis, lipemia, icterus N Cross-reactions that may invalidate the results This type of information may be summarized in checklists for quick reference at the workstation. Recommended actions to verify the validity and consistency of the generated test results: N Internal and external quality control procedures and their frequency N Calibration procedures and schedule N Preparation of quality control materials N Quality control validation data Accurate description of the analytical procedure, from instrument calibration to sample preparation, sample analysis, and result calculation. N Biological reference intervals N Reportable intervals N Critical values N Follow-up actions for unexpected results or those falling outside the reportable intervals (e.g., recheck after sample dilution, repeat analysis, pathologist review criteria) Short title, unique identification number, revision number/date, number of pages, authorizing signature laboratories have no compulsory quality requirements, and quality requirements based on clinically relevant information are rarely available. 5 Recently, quality requirements for several canine analytes based on analytical performance criteria (e.g., maximum allowable total error, imprecision, bias) calculated from data on biological variation have been proposed. 9 The international quality standards do not indicate specific quality requirements to be met by veterinary clinical pathology laboratories. This is understandable because the quality requirements may differ with laboratory type, clients, use of the laboratory data, and species of interest. However, both the ISO/IEC and standards indicate that the laboratory shall use examination procedures that meet the needs of the client/user of the service, while the OIE standard and the AAVLD essential requirements recommend including international/scientific acceptance and client expectations among the many criteria to be adopted for selecting a test method and the required quality for the test. Until widely accepted quality requirements are developed, a critical point for a veterinary clinical pathology laboratory willing to implement a quality management system is to establish its own quality requirements. As indicated by the ISO, OIE, and AAVLD standards, the quality requirements for examination procedures should be based on the needs and expectations of clients/laboratory users. The utilization of quality requirements obtained from human proficiency testing has been suggested as a possible starting point. 5,9 An obvious limitation of this approach is represented by the differences in needs and expectations between veterinary and human clinical pathology laboratory users. Additionally, the selection of analytical methods for veterinary clinical pathology laboratories is often limited by cost, and the performance of the adopted method may not be sufficient to meet stringent human quality requirements. Nevertheless, this approach may provide realistic estimates of quality requirements attainable with the analytical method, assuming that these data are critically evaluated against the needs and
6 Quality documentation 271 expectations of laboratory users, particularly in respect to medically important changes such as clinical decision limits and medically significant changes specific for the target animal species. Use of human analytical methods or modified methods for animal species Many clinical pathology veterinary tests are performed adopting human analytical methods or their modifications, and require validation before they can be routinely used for animal species. Validation may be defined as the demonstration that the method performs adequately for a specifically defined purpose throughout the range of analyte concentrations and test materials to which it is applied. 14 The implementation of a quality management system in veterinary laboratories requires the adoption of validated analytical methods and may represent a further guarantee of the quality of results to clients/users of the service. The ISO/IEC provides explicit guidance about the scope and techniques to be adopted for method validation, but it recognizes that validation is always a balance between costs, risks, and technical possibilities. 8 Specific guidance for validating diagnostic assays for animal infectious disease can be found in the Manual of Diagnostic Tests and Vaccines for Terrestrial Animals (World Animal Health Organization [OIE]: n.d., Principles of validation of diagnostic assays for infectious diseases. In: Manual of diagnostic tests and vaccines for terrestrial animals. Available at: mmanual/a_00010.htm. Accessed November 16, 2007). The application of the same principles outlined in the OIE manual is recommended by the AAVLD standard for evaluating other test methods in veterinary laboratories. General principles of method validation are also available from other publications. 9,16 The AAVLD essential requirements for accreditation define a method as validated for use if adequate performance is demonstrated with ongoing documentation of internal or inter-laboratory use of known reference standards for the species and/or diagnostic specimens of interest. Alternatively, a validated method can be defined as one or more of the following: 1) endorsed or published by reputable technical organizations such as the OIE; 2) published in a peer-reviewed journal with sufficient documentation to establish diagnostic performance and interpretation of results; or 3) documentation of internal or interlaboratory comparison to an accepted methodology or protocol. 1,18 With the exception of infectious disease testing, there is limited availability of large collaborative validation studies addressing animal analytical methods. Consequently, in some cases it is necessary for veterinary clinical pathology laboratories to perform single-laboratory method validation. Unfortunately, this type of study is often expensive and may be limited by technical problems (e.g., number of available subjects, lack of a gold standard). In such circumstances it is important that the laboratory identifies (in agreement with its clients) which characteristics need to be evaluated. In the absence of mandated requirements, the extent of the evaluation undertaken by the laboratory must meet client expectations, bearing in mind that often the data regarding method performance obtained from singlelaboratory validation studies are not robust enough to fulfill OIE validation standards. 8,14 Availability of quality control materials for animal samples All of the quality standards usually applied to laboratories recommend the implementation of internal QC procedures to verify the validity and consistency of the generated test results. The use of suitable certified reference standards and materials is recommended by the ISO to ensure the quality of examination procedures. The OIE and AAVLD standards also include the availability of QC materials among the criteria to be adopted for method selection. However, when human analytical methods (or their modifications) are applied to animal species, the implementation of statistical QC procedures may be limited by the availability of QC materials satisfactory for veterinary clinical pathology laboratories (e.g., biologically significant analyte concentrations for specific animal species) or matrices representative of animal origin. In such cases, alternative QC procedures (e.g., nonstatistical) may be implemented and the rationale of these actions justified in the procedure instructions of the SOP. Examples of nonstatistical QC that may be implemented in veterinary laboratories include providing criteria for repeat testing, technical supervisor review, and pathologist s review. In addition, there may be reflex testing (i.e., if a particular result is obtained, then additional testing is initiated). For many tests, correlation with other tests and clinical signs may help provide confidence in the interpretation of the test results. If the test result does not appear to fit with those obtained for other tests or does not correlate well with the clinical signs of the patient, then additional evaluation and investigation is warranted to determine if there may be an error or if additional testing may be required. Other nonstatistical QC that can be initiated in any laboratory, but that may be of special importance in veterinary laboratories, include review of patient data and
7 272 Sacchini, Freeman percentages of positive tests for particular tests and species for specified time periods (e.g., percent positive feline leukemia virus results for a specified period, such as shift, week, or month). The nonstatistical QC implemented by various veterinary clinical pathology laboratories may vary depending on the type of laboratory, volume of testing, technical and pathological expertise, and other factors. Availability of proficiency testing programs for veterinary clinical pathology laboratories Participation in proficiency testing programs is required by the ISO and OIE. Relatively few proficiency testing programs are specific for veterinary testing (Veterinary Laboratories Agency: n.d., Proficiency testing or external quality assessment schemes. Available at: corporate/vla/eqa/ptschemes.html. Accessed November 16, 2007). 17 Human-based proficiency testing programs may not test levels of analytes significant for veterinary clinical pathology laboratories and may not represent differences in matrix, analytes, or other factors important for animal species testing. However, human-based quality assurance (QA) programs offer an opportunity for external QA when veterinary-based programs are not available. Inclusion of species-specific reference intervals Though veterinary laboratories analyze specimens obtained from a variety of animal species, the reference intervals are often poorly defined, particularly in the case of rare or exotic species. Beyond cost, several factors may complicate the establishment of specific laboratory reference intervals for animal species. Regulations may prohibit the collection of blood samples from healthy animals for this purpose. In other cases, an adequate number of suitable subjects may not be readily available, or technical issues such as analyte stability, may limit the transport of fresh material to the laboratory. Including reference intervals for quantitative test results in the test report is recommended by all quality standards. When species-specific reference intervals are not available and the laboratory-specific reference intervals cannot be established, the verification of published reference intervals is stimulated by adopting a quality management system. The selection of at least 120 animals is typically recommended to establish reference intervals. 13 However, the availability of such a large number of independent samples is often unrealistic when dealing with animal species. Sixty animals may be acceptable if the resultant reference distribution is Gaussian, but even finding 60 animals may be prohibitive for a veterinary laboratory. 11 In such circumstances, previously published reference intervals may be verified by analyzing specimens from 20 animals representative of the reference sample population. If 2 or fewer samples fall outside the claimed reference limits, the reference interval is considered to be verified. 16 If no previously published reference intervals are available, and fewer than 60 animals are used to establish a new reference interval, the maximum and minimum observed test values, and possibly a histogram showing the distribution of the values, should be reported. Finally, reference intervals are sometimes calculated from the comparative method, using the regression equation established from statistical analyses. 16 Conclusion Documentation is an important part of any veterinary laboratory quality system. Careful thought about the aspects of the laboratory that need documentation to achieve external certification or to demonstrate a quality system without external certification is required. The type of documentation and document control required by external certification programs is usually well defined, but the specifics of the documentation may vary among veterinary clinical pathology laboratories because the type of testing, scope of testing, and client needs may differ. Several unique challenges must be addressed when implementing quality systems. This article has outlined possible solutions and/or courses of action that may help to overcome some of these unique challenges, but it is not meant to be exhaustive or prescriptive. It is the authors intent to stimulate a discussion about these topics among the veterinary clinical pathology community, starting for instance, with the need for a consensus on establishing quality requirements for veterinary tests. References 1. American Association of Veterinary Laboratory Diagnosticians (AAVLD): 2006, Essential requirements for an accredited veterinary medical diagnostic laboratory. Version 4.1. AAVLD, Davis, CA. 2. Burnett D: 2002, A quality management system and documentation. In: A practical guide to accreditation in laboratory medicine, ed. Burnett D, Poyser KH, Sherwood RA, pp ACB Venture Publications, London, UK. 3. Clinical and Laboratory Standards Institute (CLSI): 2006, Laboratory documents: development and control; approved guidelines, 5th ed. CLSI, Wayne, PA. 4. Freeman KP, Bauer N, Jensen AL, Thoresen S: 2006, Introduction to ISO 15189: a blueprint for quality systems in veterinary laboratories. Vet Clin Pathol 35: Freeman KP, Gruenwaldt J: 1999, Quality control validation in veterinary laboratories. Vet Clin Pathol 4: Garcia F, Harrison E, Wise C, Wolk D: 2003, Is your document control out of control? Complying with document control regulation. Clin Leadership Manage Rev 17:
8 Quality documentation International Organization for Standardization (ISO)/International Electrotechnical Commission (IEC): 2003, International Standard Medical laboratories Particular requirements for quality and competence. ISO, Geneva, Switzerland. 8. International Organization for Standardization (ISO)/International Electrotechnical Commission (IEC): 2000, International Standard General requirements for the competence of testing and calibration laboratories. ISO, Geneva, Switzerland. 9. Jensen AL, Kjelgaard-Hansen M: 2006, Method comparison in the clinical laboratory. Vet Clin Pathol 3: Kenny D, Fraser CG, Petersen PH, Kallner A: 1999, Consensus agreement. Scand J Clin Lab Invest 59: Lumsden JH: 2000, Reference values. In: Schalm s veterinary hematology, ed. Feldman BF, Zinkl JG, Jain NC, 5th ed., pp Lippincott Williams & Wilkins, Philadelphia, PA. 12. Shifman RB, Cembrowsky G, Wolk D: 2004, Quality management. In: Clinical laboratory management, ed. Garcia LS, et al., pp American Society of Microbiology Press, Washington, DC. 13. Stockham SL, Scott MA: 2002, Fundamentals of veterinary clinical pathology. Iowa State University Press, Ames, IA. 14. Thompson M, Ellison SLR, Wood R: 2002, Harmonized guidelines for single-laboratory validation of methods of analysis. Pure Appl Chem 74: U.S. Environmental Protection Agency: 2001, Guidance for preparing standard operating procedures (SOPs). Office of Environmental Information, Washington, DC. 16. Westgard JO: 2003, Basic method validation, 2nd ed. Westgard QC, Madison, WI. 17. Wiegers AL: 2004, The quality assurance of proficiency testing programs for animal disease diagnostic laboratories. J Vet Diagn Invest 16: World Animal Health Organization (OIE): 2002, OIE standard for management and technical requirements for laboratories conducting tests for infectious animal diseases. In: OIE quality standard and guidelines for veterinary laboratories: infectious diseases, pp OIE, Paris, France.
Checklist. Standard for Medical Laboratory
Checklist Standard for Medical Laboratory Name of hospital..name of Laboratory..... Name. Position / Title...... DD/MM/YY.Revision... 1. Organization and Management 1. Laboratory shall have the organizational
REQUIREMENTS FOR AN ACCREDITED VETERINARY MEDICAL DIAGNOSTIC LABORATORY
REQUIREMENTS FOR AN ACCREDITED VETERINARY MEDICAL DIAGNOSTIC LABORATORY AMERICAN ASSOCIATION OF VETERINARY LABORATORY DIAGNOSTICIANS, INC. Version 6.1 AC-201, Version 6.1, 06-01-12 Page 1 of 27 Table of
Content Sheet 10-1: Overview of External Quality Assessment (EQA)
Content Sheet 10-1: Overview of External Quality Assessment (EQA) Role in quality management system Assessment is a critical aspect of laboratory quality management, and it can be conducted in several
JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition
JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR CliniCAl laboratories 2nd Edition Effective 1 April 2010 International Patient Safety Goals (IPSG) Goals The following is a list of all goals.
The age of competence: an update on the international laboratory accreditation scene for veterinary testing laboratories
J Vet Diagn Invest 14:89 96 (2002) SPECIAL ARTICLE The age of competence: an update on the international laboratory accreditation scene for veterinary testing laboratories Ann L. Wiegers Abstract. Many
Gap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing
Gap Analysis May 2013 Issued: May 2013 Gap Analysis of and in the field of Medical Testing Copyright National Association of Testing Authorities, Australia 2013 This publication is protected by copyright
ISO/IEC 17025 QUALITY MANUAL
1800 NW 169 th Pl, Beaverton, OR 97006 Revision F Date: 9/18/06 PAGE 1 OF 18 TABLE OF CONTENTS Quality Manual Section Applicable ISO/IEC 17025:2005 clause(s) Page Quality Policy 4.2.2 3 Introduction 4
NABL NATIONAL ACCREDITATION
NABL 160 NABL NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES GUIDE for PREPARING A QUALITY MANUAL ISSUE NO. : 05 AMENDMENT NO : 00 ISSUE DATE: 27.06.2012 AMENDMENT DATE: -- Amendment
LAP Audioconference How to Prepare and Comply with Your Quality Management Plan* February 18, 2009
LAP Audioconference How to Prepare and Comply with Your Quality Management Plan* February 18, 2009 Paul Bachner, MD, FCAP Professor & Chair Department of Pathology & Laboratory Medicine University of Kentucky
Individualized Quality Control Plan (IQCP) Frequently Asked Questions Date: May 5, 2015 (last updated 05/13/2016)
Topic: Individualized Quality Control Plan (IQCP) Frequently Asked Questions Date: May 5, 2015 (last updated 05/13/2016) Click on the links below to be taken to a specific section of the FAQs. General
2009 LAP Audioconference Series. How to Prepare and Comply with Your Quality Management Plan
2009 LAP Audioconference Series How to Prepare and Comply with Your Quality Management Objectives: As a result of participating in this session, you will be able to: Explain the reasons why the QM is important
FINAL DOCUMENT. Guidelines for Regulatory Auditing of Quality Management Systems of Medical Device Manufacturers Part 1: General Requirements
GHTF/SG4/N28R4:2008 FINAL DOCUMENT Title: Guidelines for Regulatory Auditing of Quality Management Systems of Medical Device Manufacturers Authoring Group: GHTF Study Group 4 Endorsed by: The Global Harmonization
State Meat and Poultry Inspection (MPI) Program Laboratory Quality Management System Checklist
This checklist is intended to help laboratories improve the quality of their testing programs with regard to meat and poultry testing samples, in order to ensure those laboratories are at least equal to
1.0 INTRODUCTION 1.1 Overview
Guidance document for the writing of standard operating procedures (Taken from United States Environmental Protection Agency Guidance for Preparing Standard Operating Procedures (SOPs) EPA QA/G- 6 [EPA/600/B-
NIST HANDBOOK 150 CHECKLIST
NIST HANDBOOK 150 CHECKLIST Instructions to the Assessor: This checklist addresses the general accreditation criteria prescribed in NIST Handbook 150, NVLAP Procedures and General Requirements (2006 edition).
American Association for Laboratory Accreditation
Page 1 of 6 1.0 INTRODUCTION These accreditation requirements are applicable to the special competition animal drug testing laboratory accreditation program. This program is designed to meet the requirements
QUALITY MANAGEMENT IN VETERINARY TESTING LABORATORIES
NB: Version adopted by the World Assembly of Delegates of the OIE in May 2012 CHAPTER 1.1.4. QUALITY MANAGEMENT IN VETERINARY TESTING LABORATORIES SUMMARY Valid laboratory results are essential for diagnosis,
Standards for Laboratory Accreditation
Standards for Laboratory Accreditation 2013 Edition cap.org Laboratory Accreditation Program Standards for Accreditation 2013 Edition Preamble Pathology is a medical specialty essential to patient care
ISO 9001:2008 STANDARD OPERATING PROCEDURES MANUAL
8200 Brownleigh Drive Raleigh, NC 27617-7423 Phone: (919) 510-9696 Fax: (919) 510-9668 ISO 9001:2008 STANDARD OPERATING PROCEDURES MANUAL ALLIANCE OF PROFESSIONALS & CONSULTANTS, INC. - 1 - Table of Contents
International Commission on Trichinellosis (ICT) Recommendations for Quality Assurance in Digestion Testing Programs for Trichinella.
International Commission on Trichinellosis (ICT) Recommendations for Quality Assurance in Digestion Testing Programs for Trichinella These Recommendations were developed, in part, during a Workshop sponsored
USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY
USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY Breakout Session 3B Tuesday, May 1 8:30 10 am James Blackwood, MS, CLSI David D. Koch, PhD, FACB, DABCC, Pathology & Laboratory
QUALITY MANUAL GREAT LAKES INSTITUTE FOR ENVIRONMENTAL RESEARCH ANALYTICAL LABORATORIES. October 2008 Revision 08
QUALITY MANUAL GREAT LAKES INSTITUTE FOR ENVIRONMENTAL RESEARCH ANALYTICAL LABORATORIES October 2008 Revision 08 Great Lakes Institute for Environmental Research University of Windsor Windsor, Ontario
Medical Cannabis Laboratory Approval Program
Medical Cannabis Laboratory Approval Program Application Process and Required Documentation After the publication of the Medical Cannabis Laboratory Application, currently expected by February 16, 2015,
Quality Management System Policy Manual
Quality Management System Burns Engineering, Inc. 10201 Bren Road East Minnetonka, MN 55343 4. 4.1 General Requirements The Quality Manual consists of the quality system policy documents and the quality
Company Quality Manual Document No. QM Rev 0. 0 John Rickey Initial Release. Controlled Copy Stamp. authorized signature
Far West Technology, Inc. ISO 9001 Quality Manual Document No.: QM Revision: 0 Issue Date: 27 August 1997 Approval Signatures President/CEO Executive Vice President Vice President/CFO Change Record Rev
Best Practices for Maintaining Quality in Molecular Diagnostics Gyorgy Abel, MD, PhD
Best Practices for Maintaining Quality in Molecular Diagnostics Gyorgy Abel, MD, PhD Director, Clinical Chemistry Molecular Diagnostics / Immunology Department of Laboratory Medicine Lahey Clinic Medical
Unaccredited Point-of-Care Laboratory Testing Guideline for Physicians
Unaccredited Point-of-Care Laboratory Testing Guideline for Physicians Prepared by the Advisory Committee on Laboratory Medicine College of Physicians & Surgeons of Alberta Serving the Public by guiding
AN AUDIT QUESTIONNAIRE THAT EXAMINES SPECIFICALLY THE MANAGEMENT OF TECHNICAL ACTIVITIES CLAUSES IN ISO 15189
Indian Journal of Clinical Biochemistry, 2010 / 25 (1) 92-98 LABORATORY DOCUMENTATION AN AUDIT QUESTIONNAIRE THAT EXAMINES SPECIFICALLY THE MANAGEMENT OF TECHNICAL ACTIVITIES CLAUSES IN ISO 15189 T F Hartley
Definition of Minimum Performance Requirements for Analytical Methods of GMO Testing European Network of GMO Laboratories (ENGL)
Definition of Minimum Performance Requirements for Analytical Methods of GMO Testing European Network of GMO Laboratories (ENGL) 13 October 2008 Date of application: 13 April 2009 INTRODUCTION The scope
Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions
Bio-Rad Laboratories QC data management solutions QC Data Management Solutions Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions Bio-Rad Laboratories QC data management
MEAT GRADING AND CERTIFICATION BRANCH QUALITY MANUAL
United States Department of Agriculture Marketing and Regulatory Programs Agricultural Marketing Service Livestock and Seed Program Meat Grading & Certification Branch MGC Instruction 800 May 9, 2005 Page
Example of a food company quality
Appendix A manual Example of a food company quality Contents Date: 13/03/95 RME-QLMN-OO Page 1 of 3 Section Title ISO 9001 reference 01 In trod uction 02 Purpose 03 Scope 04 Definitions 05 Management responsibility
IAS ACCREDITED INSPECTION AGENCIES: GUIDELINES FOR CONDUCTING INTERNAL AUDITS AND MANAGEMENT REVIEWS. Revised January, 2016
IAS ACCREDITED INSPECTION AGENCIES: GUIDELINES FOR CONDUCTING INTERNAL AUDITS AND MANAGEMENT REVIEWS Revised January, 2016 IAS has found that inspection agency personnel are often confused by the requirements
Good Research Practice
Page 1 of 8 The Royal Veterinary College Introduction Preface Good Research Practice Funding bodies need to be assured of the quality and validity of research they fund and ensure their contractors are
NABL accreditation is a formal recognition of the technical competence of a medical testing laboratory
NABL accreditation is a formal recognition of the technical competence of a medical testing laboratory Third party assessment NABL has Mutual Recognition Arrangement with APLAC and ILAC NABL accredited
CHAPTER 13. Quality Control/Quality Assurance
CHAPTER 13 Quality Control/Quality Assurance Quality Control/Quality Assurance (QC/QA) can be defined as the set of planned and systematic activities focused on providing confidence that quality requirements
Laboratory Director Responsibilities
Clinical Laboratory Improvement Amendments (CLIA) Laboratory Director Responsibilities What Are My Responsibilities As A Laboratory Director NOTE: Congress passed the Clinical Laboratory Improvement Amendments
EPA NATIONAL LEAD LABORATORY ACCREDITATION PROGRAM. LABORATORY QUALITY SYSTEM REQUIREMENTS (LQSR) REVISION 3.0 (November 05, 2007)
EPA NATIONAL LEAD LABORATORY ACCREDITATION PROGRAM LABORATORY QUALITY SYSTEM REQUIREMENTS (LQSR) REVISION 3.0 (November 05, 2007) The requirements in this document apply to all lead testing laboratories
Methods verification. Transfer of validated methods into laboratories working routine. Dr. Manuela Schulze 1
Methods verification Transfer of validated methods into laboratories working routine Dr. Manuela Schulze 1 1. Introduction 2. Definitions and differences validation verification 3. How to perform verification
OPERATIONAL STANDARD
1 of 11 1. Introduction The International Safe Transit Association (ISTA), a non-profit association whose objective is to prevent product damage and excess packaging usage within the distribution environment.
Individualized Quality Control Plan
NOVEMBER 2014 CLIA Individualized Quality Control Plan WHAT IS AN IQCP? OVERVIEW Discovering, Deciphering and Designing an Individualized Quality Control Plan (IQCP) IQCP provides a framework for customizing
Flow Cytometry. CLIA Compliance Manual*
Flow Cytometry CLIA Compliance Manual* Revised for the International Society for Advancement of Cytometry (ISAC) and Clinical Cytometry Society (CCS) By Michael Keeney ART, FIMLS Teri Oldaker B.A., CLS(NCA)QCYM
Data Management Implementation Plan
Appendix 8.H Data Management Implementation Plan Prepared by Vikram Vyas CRESP-Amchitka Data Management Component 1. INTRODUCTION... 2 1.1. OBJECTIVES AND SCOPE... 2 2. DATA REPORTING CONVENTIONS... 2
Sutter Health Support Services Shared Laboratory Position Description. Incumbent: Laboratory Date: October 23, 2006 Written By: Michele Leonard
Sutter Health Support Services Shared Laboratory Position Description Position Title: Clinical Laboratory Scientist, Microbiologist Incumbent: Entity: SHSS Shared Laboratory Reports To: Director of Operations,
OIML D 18 DOCUMENT. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL DOCUMENT OIML D 18 Edition 2008 (E) The use of certified reference materials in fields covered by metrological control exercised by national services of legal metrology. Basic principles
Haulsey Engineering, Inc. Quality Management System (QMS) Table of Contents
Haulsey Engineering, Inc. Quality Management System (QMS) Table of Contents 1.0 Introduction 1.1 Quality Management Policy and Practices 2.0 Quality System Components 2.1 Quality Management Plans 2.2 Quality
DEC STD 017-2 - ISO 9002 - Quality Systems - Model for Quality Assurance in Production and Installation
Digital Internal Use Only DEC STD 017-2 - ISO 9002 - Quality Systems - Model for Quality Assurance in Production and Installation DOCUMENT IDENTIFIER: A-DS-EL00017-02-0000 Rev A, ABSTRACT: This standard
5th Edition NetCord-FACT International Standards for Cord Blood Collection, Banking, and Release for Administration. Summary of Changes
5th Edition NetCord-FACT International Standards for Cord Blood Collection, Banking, and Release for Administration Summary of Changes This document summarizes the changes made to the 5th edition of the
ISO 9001 Quality Systems Manual
ISO 9001 Quality Systems Manual Revision: D Issue Date: March 10, 2004 Introduction Micro Memory Bank, Inc. developed and implemented a Quality Management System in order to document the company s best
2010 Laboratory Accreditation Program Audioconference. Accreditation Requirements for Waived Vs. Non-waived Tests
2010 Laboratory Accreditation Program Audioconference Accreditation Requirements for Waived Vs. Non-waived Tests Objectives: After participating in this audioconference you will be able to: Define the
COMPLIANCE BY DESIGN FOR PHARMACEUTICAL QUALITY CONTROL LABORATORIES INSIGHT FROM FDA WARNING LETTERS
COMPLIANCE BY DESIGN FOR PHARMACEUTICAL QUALITY CONTROL LABORATORIES INSIGHT FROM FDA WARNING LETTERS Primer CONTENTS INTRODUCTION...3 QUALITY AND COMPLIANCE IN QUALITY CONTROL LABORATORIES...5 Compliance
ALACC Frequently Asked Questions (FAQs)
Updated October 17, 2012 ALACC Contents Web Introduction to FAQ... 2 FAQ #6... 3 ALACC Section: How to Meet ISO 17025 Requirements for Method Verification (Page 9)... 3 FAQ #13... 4 ALACC Section ALACC
General Information. Our Background Automated Phone Services Holiday Coverage Licenses & Accreditations
General Information Our Background Automated Phone Services Holiday Coverage Licenses & Accreditations Our Background Foundation Laboratory is an advanced, accredited and certified clinical diagnostic
1 For more information T: +1.847.664.1499 / E: [email protected] / W: ul.com/dap
DATA ACCEPTANCE PROGRAM UL Client Test Data Program Investigations of products by UL typically involve the testing of product samples. While UL maintains extensive facilities for these purposes, customers
CORPORATE QUALITY MANUAL
Corporate Quality Manual Preface The following Corporate Quality Manual is written within the framework of ISO 9001:2008 Quality System by the employees of CyberOptics. CyberOptics recognizes the importance
DRY CLEANING PROGRAM QUALITY ASSURANCE MANAGEMENT PLAN
DIVISION OF ENVIRONMENT QUALITY MANAGEMENT PLAN PART III: DRY CLEANING PROGRAM QUALITY ASSURANCE MANAGEMENT PLAN Revision 3 January 8, 2013 Kansas Department of Health and Environment Division of Environment
www.itilhelp.com ISO 9000 Quality Standard Background Information Quality Systems Implementation
ISO 9000 Quality Standard Background Information www.itilhelp.com There is a worldwide trend towards more stringent customer expectations with regard to quality. Accompanying this trend has been a growing
TITLE: Quality System Manual DOCUMENT NUMBER: QMS
1 of 19 BUSINESS PROCESS (BP) QUALITY MANAGEMENT SYS NAME SIGNATURE DATE PREPARED BY BILL ATKINSON SIGNATURE ON FILE 12/3/2014 APPROVALS DEPARTMENT NAME SIGNATURE DATE PRESIDENT DANNY ANGEL SIGNATURE ON
COPY. Revision History: Changes were made to reflect the current practice of only including the most recent changes in the revision history.
Revision History COPY The top row of this table shows the most recent changes to this controlled document. For previous revision history information, archived versions of this document are maintained by
Validation of measurement procedures
Validation of measurement procedures R. Haeckel and I.Püntmann Zentralkrankenhaus Bremen The new ISO standard 15189 which has already been accepted by most nations will soon become the basis for accreditation
ISO 9001:2008 QUALITY MANUAL. Revision B
ISO 9001:2008 QUALITY MANUAL Revision B Because we want you to achieve the highest levels of performance, we connect care Because with leading we want science you to achieve continuously the highest improve,
UCLA PATHOLOGY & LABORATORY MEDICINE QUALITY MANAGEMENT PLAN
Page 1 of 11 UCLA PATHOLOGY & LABORATORY MEDICINE QUALITY MANAGEMENT PLAN INTRODUCTION A quality management system can be described as a set of key quality elements that must be in place for an organization
Statement of Guidance
Statement of Guidance Internal Audit Unrestricted Trust Companies 1. Statement of Objectives 1.1. To provide specific guidance on Internal Audit Functions as called for in section 3.6 of the Statement
CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems
Date(s) of Evaluation: CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems Assessor(s) & Observer(s): Organization: Area/Field
Six Sigma Metric Analysis for Analytical Testing Processes
Six Sigma Metric Analysis for Analytical Testing Processes Sten Westgard, MS, Westgard QC Introduction Laboratories seek objective assessment and comparison of analytical methods and instrumentation performance.
Eagle Machining, Inc. Quality Management System
Eagle Machining, Inc. Quality Management System 1 of 10310 Antoine Drive Bldg D, Houston, Texas 77086 BUSINESS OPERATING MANUAL (QUALITY MANUAL) Revision Date: 08/01/2014 Approved By: Joseph Vu Date: 08/01/2014
AEROSPACE STANDARD. Quality Management Systems - Requirements for Aviation, Space and Defense Organizations RATIONALE
AEROSPACE STANDARD AS9100C Issued 1999-11 Revised 2009-01 Superseding AS9100B Quality Management Systems - Requirements for Aviation, Space and Defense Organizations RATIONALE This standard has been revised
Rockwell Automation Quality Management System
Rockwell Automation Quality Management System Our Quality Policy Rockwell Automation is committed to a global quality system focused on customer solutions. We achieve this through superior products and
MEDICAL DEVICE GUIDANCE
May 2014 MEDICAL DEVICE GUIDANCE GN-23: Guidance on Labelling for Medical Devices PREFACE This document is intended to provide general guidance. Although we have tried to ensure that the information contained
NC SBI QUALITY ASSURANCE PROGRAM
NC SBI QUALITY ASSURANCE PROGRAM for the SBI Reviewed by: Deputy Assistant Director Bill Weis Date: Approved by: Assistant Director Jerry Richardson Date: Originating Unit: SBI Effective Date: July 25,
NIST HANDBOOK 150-5 CHECKLIST CONSTRUCTION MATERIALS TESTING
NIST HANDBOOK 150-5 CHECKLIST CONSTRUCTION MATERIALS TESTING Instructions to the Assessor: This checklist addresses specific accreditation criteria prescribed in NIST Handbook 150-5, Construction Materials
New York State Department of Health Wadsworth Center Clinical Laboratory Reference System Clinical Laboratory Evaluation Program
New York State Department of Health Wadsworth Center Clinical Laboratory Reference System Clinical Laboratory Evaluation Program Guidance for Implementing a Laboratory Quality Management System Version
Content Sheet 16-1: Introduction to Documents & Records
Content Sheet 16-1: Introduction to Documents & Records Role in quality management system The management of documents and records is one of the 12 essential elements of the quality system. The management
GLP vs GMP vs GCP Dominique Pifat, Ph.D., MBA The Biologics Consulting Group [email protected]
GLP vs GMP vs GCP Dominique Pifat, Ph.D., MBA The Biologics Consulting Group [email protected] Common Misconception Good Laboratory Practices 1) A quality system concerned with the organizational process
CLIA & Individualized Quality Control Plan (IQCP)
& Individualized Quality Control Plan (IQCP) Judith Yost, M.A., M.T.(ASCP) Director Division of Laboratory Services Centers for Medicare & Medicaid Services 1 Objectives Provide Background & History of
College of American Pathologists Laboratory Accreditation Program. Document Control Management
College of American Pathologists Laboratory Accreditation Program Document Control Management William Castellani, MD, FCAP Inter-Regional Commissioner Laboratory Accreditation Program September 19, 2007
Content Sheet 12-1: Overview of Personnel Management
Content Sheet 12-1: Overview of Personnel Management Role in quality management system Personnel are the most important laboratory resource. Critical to the implementation of the quality management system
IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS
REFERENCES NIST Special Publication 330 IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS Revised October 2013 International vocabulary of metrology Basic and general concepts and
Going Beyond Laboratory Automation: Do Less Accomplish More. Swedish Covenant Hospital
Going Beyond Laboratory Automation: Do Less Accomplish More Susan Dawson, MBA, MT(ASCP) Swedish Covenant Hospital Chicago, IL Swedish Covenant Hospital Open Heart Oncology Birthing Unit Community Outreach
Strengthening Forensic Science in the United States: A Path Forward
This PDF is available from The National Academies Press at Strengthening Forensic Science in the United States: A Path Forward ISBN 978-0-309-13135-3 Committee on Identifying the Needs of the Forensic
TEST METHOD VERIFICATION AND VALIDATION
1 TEST METHOD VERIFICATION AND VALIDATION SWACM 2014 MICHAEL LOEFFELHOLZ, PH.D., ABMM DEPT. PATHOLOGY UNIV TEXAS MEDICAL BRANCH GALVESTON, TX 2 OBJECTIVES Define validation and verification Describe components
A Comprehensive On-site Diagnostic Program for the Detection of Trichinella
A Comprehensive On-site Diagnostic Program for the Detection of Trichinella Alvin A. Gajadhar Centre for Food-borne and Animal Parasitology Canadian Food Inspection Agency Saskatoon, SK. Canada Reference
PERFORMANCE-BASED EVALUATION OF LABORATORY QUALITY SYSTEMS An Objective Tool to Identify QA Program Elements that Actually Impact Data Quality
PERFORMANCE-BASED EVALUATION OF LABORATORY QUALITY SYSTEMS An Objective Tool to Identify QA Program Elements that Actually Impact Data Quality ABSTRACT Sevdâ K Aleckson, Western Region Quality Assurance
OD-2017-Ed.1.5 CHECK LIST FOR TESTING AND CALIBRATION LABORATORIES
IECEE OD-2017-Ed.1.5 OPERATIONAL & RULING DOCUMENTS CHECK LIST FOR TESTING AND CALIBRATION LABORATORIES Rev 2006-09-22 OD-2017-Ed.1.5 IEC - IECEE 2007 - Copyright all rights reserved Except for IECEE members
ISO 9001:2000 AUDIT CHECKLIST
ISO 9001:2000 AUDIT CHECKLIST No. Question Proc. Ref. Comments 4 Quality Management System 4.1 General Requirements 1 Has the organization established, documented, implemented and maintained a quality
Guideline on good pharmacovigilance practices (GVP)
1 2 20 February 2012 EMA/541760/2011 3 4 Guideline on good pharmacovigilance practices (GVP) Module I Pharmacovigilance systems and their quality systems Draft finalised by the Agency in collaboration
ISO 9001:2008 Audit Checklist
g GE Power & Water ISO 9001:2008 Audit Checklist Organization Auditor Date Page 1 Std. 4.1 General s a. Are processes identified b. Sequence & interaction of processes determined? c. Criteria for operation
Guidance for Laboratory Quality Manuals
OLA Ontario Medical Association QUALITY MANAGEMENT PROGRAM LABORATORY SERVICES (QMP LS) Ontario Laboratory Accreditation Division (OLA) Guidance for Laboratory Quality Manuals Quality Management Program
Network Certification Body
Network Certification Body Scheme rules for assessment of railway projects to requirements of the Railways Interoperability Regulations as a Notified and Designated Body 1 NCB_MS_56 Contents 1 Normative
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (06) 72 2R (FORM/158-Rev.02) STANDARD AIDE-MEMOIRE FOR THE MJA/MJV OF OMCLs Full document title and reference Document type
Quality Manual. This Quality Manual complies with the Requirements of ISO 9001:2008 and ISO/IEC 80079-34, Explosive Atmospheres - Edition 1.
This complies with the Requirements of ISO 9001:2008 and ISO/IEC 80079-34, Explosive Atmospheres - Edition 1.0 2011-04 Prepared By: Phyllis Olsen Release Date: 10/28/15 Certificate No: CERT-08776-2006-AQ-HOU-RvA
Testing Facility Laboratory Manual
Quality Synthetic Rubber's Testing Facility Laboratory Manual Quality Synthetic Rubber, Inc. 1700 Highland Road P.O. Box 1030 Twinsburg, Ohio 44087-9030 Phone: 330-425-8472 Duns Code: 01-753-2458 Z-Code:
QUALITY MANUAL ISO 9001. Quality Management System
Page 1 of 20 QUALITY MANUAL ISO 9001 Quality Management System Printed copies are not controlled unless marked "CONTROLLED". Upon receipt of this document, discard all previous copies. Page 2 of 20 Approval
CENTRIS CONSULTING. Quality Control Manual
CENTRIS CONSULTING Quality Control Manual ISO 9001:2008 Introduction Centris Consulting developed and implemented a Quality Management System in order to document the company s best business practices,
REGULATION (EEC) No 2309/93
REGULATION (EEC) No 2309/93 Council Regulation (EEC) No 2309/93 of 22 July 1993 laying down Community procedures for the authorization and supervision of medicinal products for human and veterinary use
Quality Management System Manual
Quality Management System Manual This manual has been reviewed and approved for use by: Jack Zazulak President, Aurora Machine Limited March 07, 2011 Date - Copyright Notice - This document is the exclusive
Unique Standards and Documentation Required for Accredited CLT/MLT Programs
Unique Standards and Documentation Required for Accredited CLT/MLT Programs Section III (CLT/MLT) Page 1 UNIQUE STANDARDS AND THE REQUIRED DOCUMENTATION Objectives Clinical Laboratory Technician/Medical