Power Quality A guide to voltage fluctuation and light flicker
|
|
|
- Arline Shelton
- 10 years ago
- Views:
Transcription
1 Power Quality A guide to voltage fluctuation and light flicker Scope This guide provides a simple introduction to the theory of how light flicker is produced and how it is perceived. It includes a description of the international standards that define how voltage fluctuation should be measured and what levels are needed to reduce light flicker to acceptable levels. There are also sections describing what you can do to prevent or reduce the impact of voltage fluctuation. Introduction One of the many aspects of power quality that can affect electricity users is voltage fluctuation that causes lights to flicker. Whenever the electrical load changes, the supply voltage is affected proportionately. Most people have seen this occur in their house; when the refrigerator or the furnace starts, some of the lights may dim. If a large enough change occurs, such as the start-up of a large industrial motor, lights can dim or brighten, not only for that customer, but all over town. Normally the customer whose load is changing is the most affected, but other customers are all affected to some degree, depending on how large the load change is and how close they are to the changing load. If large voltage changes occur in rapid succession, light levels will vary, and when the variation becomes large enough to be noticeable or annoying, the effect is called light flicker. Experience has shown that most people are tolerant of an occasional dip in the lights, but when flicker is frequent or continuous, they begin to complain. How flicker is perceived The response of the eye Like other human senses, the eye has amazing capabilities. Without conscious thought, our eyes can adapt to light levels varying by a factor of 10,000 from bright sunlight to faint starlight. Despite that enormous dynamic range, we can detect variations in brightness of less than 1%. Even more impressive, dedicated parts of the brain filter the incoming information, removing background clutter and extracting the most important features. Our eyes are also extraordinarily sensitive to rapid change. As the light level gradually drops by a factor of 100 at dusk, we may be almost unaware of the change, but a 1% step change in ambient light level due to a sudden change in voltage will almost certainly attract our attention. Fundamental constraints on the response of the eye limit our perception of very rapid events. The mechanisms of converting light into nerve impulses take a finite time to occur, so the brain has averaging mechanisms that smooth out the time delay between nerve impulses, presenting us with a constant picture, despite the bucket brigade nature of the
2 2 incoming signals. As a result of this automatic smoothing, pictures displayed in rapid succession appear continuous, an effect that movies and television use to good advantage. Gaps shorter than about 50 milliseconds (1/20 of a second) are filled in, as our processing system ignores them as it would variations in nerve impulses, and averages them out. We are, therefore, quite insensitive to changes that occur at frequencies above about 20 cycles per second. It is no coincidence that our television and electric lights run at 60 cycles per second, fast enough that they do not appear to flicker. The net result of the balance between averaging and pupil adaptation is that our sensitivity to changing light levels increases the faster they change, up to the point where the finite response time of the eye and the automatic smoothing mechanism begin to come into effect. This begins to occur at about 9 cycles per second, the frequency at which we are most sensitive to light flicker. The effect of voltage on light output There is one more level of complication involved when we consider the effect of variations in supply voltage. Since we are concerned with the effect of light flicker caused by voltage changes, we must consider not only the perception process, but also the conversion of electricity into light, and the way that the output level of a lamp depends on the power supply voltage. Different lamp types (incandescent, fluorescent, arc lamps) respond differently, but in general the light output is proportional to the power consumption, although the power is not necessarily proportional to the voltage. In ballasted lamps, such as arc lamps and fluorescents, the ballast stabilizes the power, which is therefore more or less proportional to the voltage. Incandescent lamps act like resistors, so the power is roughly proportional to the square of the voltage (actually, the dependence is changed slightly by the fact that the resistance increases as the filament temperature increases). As a result, incandescent lamps tend to be the most sensitive to changing voltage, and so flicker calculations are based on incandescent lamps as a worst case. An incandescent lamp produces light by passing electric current through a tungsten filament until it glows white-hot. We tend to think that when we turn on the switch, the light comes on instantly, but in fact it takes around a tenth of a second for the filament to heat up completely. Like any other object, it has a certain amount of thermal inertia, although because it is small, the time it takes to heat up is short. As we have seen, moderately fast changes are the most visible, and the filament time constant is close enough to the frequencies of interest that it must be taken into account. Thermal inertia provides another smoothing mechanism that reduces the impact of higher-frequency changes and slows down step changes. The thermal inertia depends on the size and shape of the filament, and so this term dictates a slightly different response curve in Europe, where 220-volt lamps are used, from North America, where the standard is 120 volts. Figure 1 shows the light output of an incandescent lamp when the 60 Hz power is turned on. After the filament warms up, the light output has a substantial amount of flicker. Note that because the filament heats equally with positive and negative voltages, the flicker frequency is doubled to 120 Hz, too fast to be visible to the human eye. Light Voltage time (ms) Figure 1. The light output of an incandescent lamp during starting
3 3 The threshold of perceptibility All of these factors taken together determine how likely a given level of flicker is to be noticed by an observer. It is difficult to classify levels of visibility; the only quantitative measure is to determine the threshold of perceptibility. This can be done in a scientific way by presenting observers with a light source that has variable amounts of flicker and asking them to press a button or make a signal when the light seems to flicker. Different individuals have different sensitivities, so trials with a number of observers are required to achieve repeatable results. The threshold of perception is defined as the amount of flicker that is perceptible to 50% of observers. These experiments have been performed in numerous studies, and a standard flicker perceptibility curve, shown in Figure 2 below, has been drawn based on the results. The curve shows the percentage voltage variation at the threshold of perception for different flicker shapes and repetition frequencies. 3% Flicker Perception Threshold At frequencies near the peak sensitivity (8.8 Hz), voltage variations as small as 0.2% can be perceived. At higher frequencies, the thermal inertia of the lamp filament and the averaging of the eye mean that larger changes must occur before they are visible. For square variations, the response at medium to high frequencies is quite similar to that for sine waves, but a little more sensitive. At low frequency, step changes appear as independent events, and the threshold of perceptibility levels off at a constant value of 0.5% Square wave Sine wave Time (ms) 2% % 0% Figure 2. Flicker perception threshold vs frequency Smooth change Step change Frequency (Hz) The tests can be done with two types of flicker: smooth sinusoidal variations, or square waves with sharp step changes, as shown in Figure 3. As you might expect, smooth variations are much less perceptible, especially at low frequencies, where the adaptation of the eye tends to conceal the changes Time (ms) Figure 3. Test voltage waveforms for flicker perception
4 4 How flicker is produced Voltage fluctuation basics Voltage fluctuation, or variation in the voltage at the electrical outlet, can be caused by events at many different points in the power distribution system. For most consumers, power generated by many large generators comes to them through a high-voltage electrical transmission network, or grid. Power flows through this grid at voltages around 100 or 200 kv to a substation, where the voltage is reduced by a transformer to a lower voltage, typically 12 to 25 kv. It then flows through an underground or overhead distribution system until it reaches a distribution transformer, where it is reduced further to the consumer voltage (typically 120/240 V in a single-phase service or 120/208 V or 347/600 V in a three-phase service). The power then flows through a service conductor to the customer s meter and distribution panel and through the building electrical system to the outlet or light fixture. The voltage at the outlet is determined by two factors: the generator output voltage and the voltage drop, or loss, in the transmission and distribution system. Rapid variations in the generator output voltage occur very infrequently. BC Hydro manages voltages at different points in the grid to maintain maximum efficiency and proper flow of power, and changes to voltage and power flow are carried out slowly in a controlled manner. Generators are equipped with automatic voltage regulators to maintain output voltage levels despite changes in load, and BC Hydro has voltage regulators in its distribution system. It is only when a major event, such as a transmission line outage due to a lightning strike or mechanical failure, occurs, or when system demand is greater than the combined available generation capacity, that the regulators are unable to maintain the voltage. Under these conditions there may be a temporary undervoltage or overvoltage until the condition is corrected, or, in the worst case, the system may become unstable, causing some areas to lose power completely and other areas to separate from the grid. Fortunately, this type of event is extremely rare even one or two events a year is considered unacceptable and corrective action is taken to prevent future repetitions. Most voltage variations are caused by changes in the voltage drop in the distribution system. Each component of the system has losses associated with it, and produces a voltage drop that is approximately proportional to the current flowing through it. The ratio of voltage drop to current flow is called the impedance, and can conveniently be expressed as the percentage drop in voltage at rated current. Transformer impedances vary; for example, an impedance of 10% means that the output voltage of the transformer will be 10% lower when it is fully loaded than when it has no load. The output voltage of a 120 V distribution transformer with 10% impedance might vary from 126 V at no load to 114 V at rated load. Distribution lines, service conductors and house wiring each produce a voltage drop as well, typically around 3% each at full load. For these impedances, the total voltage drop from the grid to the outlet, if every component were loaded to its maximum limit, would be 19%. In practice, most of the distribution system components are normally loaded to around 50% of their rating, and because the total distribution load is the sum of many customer loads, the voltage drop is usually fairly stable, in the range of 5% to 10%. Individual customer circuit loads vary from 0 to 100% of rated load, but even in a single house it is quite unlikely that all the appliances and lights would be on at the same time, so the total load of a single customer might vary from 10% to 90%. Loads change all the time, through manual switching, thermostats or changes in motor loads. When you push a piece of wood through your table saw, the current increases substantially as it tries to keep the blade spinning against the increased resistance, and the current drops again when the resistance ceases. In the same way, industrial loads such as wood chippers or conveyer belts draw more or less current,
5 5 depending on the motor loading. Any time a load changes, it affects the voltages throughout the electrical system, although most of the changes are so small as to be undetectable. Let us take as an example your 3/4 hp, 120 V table saw, plugged into an outlet in the workshop. When the saw is switched on, it probably draws about 30 A, or twice the current rating of the circuit, for a second or so, then drops back to about 3 A at idle. The 30 A momentary current will increase the current draw throughout the system. The magnitude of the current increase in the distribution line is reduced by the distribution transformer ratio. For a 14.4 kv line, the ratio is 120:1, and the load current surge will be 0.25 A at 14.4 kv. If we assume the substation transformer is rated for 1,000 amps with a 10% impedance, this will create a voltage drop of (0.25/1,000) x 10% = % at the transformer output. A typical distribution line one mile long might have an impedance of 3% at a rated current of 300 A, for a further voltage drop of (0.25/300) x 3% = % at the distribution transformer. It is clear that the impact of the load change on the overall power system is undetectable Figure 4. Total voltage dip at different points As we get closer to the load, the effects become greater. A typical small pole-mounted residential distribution transformer is rated 100 A at 120/240 V, and if we assume 10% impedance, the starting surge will create a voltage drop of about (30/100) x 10% = 3%. 3.0 Substation Line Transformer Panel Outlet Several houses probably share the transformer, and each of them will see a momentary 3% dip in voltage, large enough that your neighbours lights will flicker. The service conductor to a house usually has about 2% impedance at 100 A, so all the lights in your house will see an additional dip of 0.6%, for a total of 3.6%. Number 14 wire has a rating of 15 A and an impedance of about 0.06% per foot, so if there is a lamp plugged into the same outlet as the saw, 30 feet from the panel, the wiring will drop the lamp voltage by a further 3.6%, for a total dip of 7.2%. Figure 4 illustrates the voltage drops in this example. This illustrates how voltage variations propagate through the system. The closer you are to a varying load, and the farther from the substation, the more you will be affected. Most flicker and voltage variation problems affect the customer whose load is changing, or his or her immediate neighbours. The exception, and the most difficult case to deal with, is when a commercial or industrial load has frequent changes that are large enough to affect the voltage on the distribution line, and therefore to impact all the customers sharing that line. As the example illustrates, this occurs only with large load changes. Given the distribution system described above, to reach the threshold of perception (about 0.5% change for an isolated event), a distribution current surge of about 25 A would be required. For a three-phase load, this is equivalent to a load change of about 1 MW, or the starting current on a 300 hp motor. Common flicker sources Isolated events such as motor starts and process shutdowns can cause changes in voltage, but these isolated events are not classified as flicker. The public does not generally see these events as a major annoyance, as long as the voltage changes are infrequent and not large enough to cause problems other than minor perceptible light flicker. The most difficult sources of repetitive flicker are large loads that fluctuate at frequencies in the vicinity of the peak sensitivity region, near 10 cycles
6 6 per second. The classic example is an arc furnace, which has a large random variation in load current due to the nature of the arc. The variations are erratic, but often include substantial components in the range of 1 to 20 cycles per second. For a furnace located in an urban area with a strong distribution system, flicker may become a concern at load levels around 1 MW or more. Any arc furnace located far from a substation on a relatively weak line could be a source of flicker and should be checked for possible flicker problems. Another fairly common flicker source is a wood chipper that chops wood into chips for pulp and paper or for waste wood disposal. These machines consist of a chipping wheel driven by a large motor. As the wood is fed in at intervals, the motor current changes as the chipping wheel is loaded or unloaded, and affects the voltage as shown in Figure 5. The fluctuation rate depends on the feed material and mechanism, and may produce flicker in the sensitive frequency range. Since they are mostly rural, many of these plants are located at the end of weak distribution lines, and are therefore possible flicker sources, even if the load is only in the range of 100 hp or so. V A Voltage Current s Figure 5. Wood chipper voltage fluctuations Electric heating, either process heating or space heating, is a potential source of flicker, but in most cases this heating is controlled in a rather slow cycle by a thermostat or process controller, and the changes are infrequent enough to avoid the most sensitive frequency range. If the load is large and the impedance is high enough, however, electric heating can be a source of annoying flicker, especially in the same building. Particular care should be taken with electronic thermostats, since they can have very fast control cycles. Controllers with cycle times of a few seconds or less should be avoided, since their load cycling can lead to high levels of local flicker. Periodic variations at higher frequencies that are close together can produce flicker at their beat, or difference, frequency, like two guitar strings tuned close together. This effect is primarily a concern with multiple adjustable speed drives running at slightly different frequencies, say 50 and 55 Hz. On the source side, diesel generators can contribute to voltage fluctuations, particularly if there are variations in the fuel supply. These are just a few examples other load types can also produce flicker if the conditions are right. The key thing to look for is frequent load changes of substantial magnitude in relation to the distribution line capability. Whenever this type of load is on line, the potential for flicker is there. Types of voltage variation Flicker sources in the power system may generate smooth changes or step changes, and anything in between, and the shape has an impact on flicker perceptibility. A load such as a wood chipper is a good example of a square wave flicker source. As each piece of wood feeds into the chipper, the power demand increases suddenly when the chipper bites into the wood, and then drops quickly back to no load when the piece is consumed. Loads using modern adjustable speed drive controls, on the other hand, tend to resemble the sine wave variation, since most drives have adjustable ramping limits that produce a smooth, controlled acceleration and deceleration to minimize stress on the equipment as well as flicker. In many cases, the flicker shape is not a regular periodic change, and a complicated mathematical calculation is required to estimate the threshold of perceptibility.
7 7 Figure 6 shows an example of an irregular RMS* voltage variation that was measured when an irrigation pump started on a rural distribution line. This sort of variation needs a more advanced treatment than simply looking it up on the perceptibility threshold curve Time (seconds) Figure 6. An irregular motor starting voltage transient Non-repetitive events In the standards, it is clear that flicker refers only to repetitive variations in the power supply voltage. Occasional individual events such as motor starts, utility circuit switching and equipment failures or trips, if they are not repeated on a regular basis, are specifically excluded from the category of flicker. This is not to say that occasional voltage changes do not affect power quality; they should certainly be monitored and kept down to tolerable levels. Such events should be treated in the same way as other disturbances like undervoltage, overvoltage, transients and outages. The most common event of this type is the starting current surge for an infrequently started motor. Guidelines are available for the maximum voltage dip on motor starting. In a new motor installation, the voltage dip should be calculated from the starting current and system impedance, and if the guidelines will be exceeded, a soft-start mechanism, such as reduced-voltage starting, should be applied. * RMS (root means square) refers to the most common mathematical method of defining the effective voltage or current of an AC wave. Flicker measurement Early flicker measurement In the early days of the power system, measurement and analysis tools were primitive. Problems with flicker occurred from time to time, and engineers of the day developed empirical guidelines as to what levels of flicker were tolerable and what levels would likely lead to complaints. In keeping with the tools at their disposal, the parameters they used were simplified. 9 8 IEEE Rural limit 5 4 Urban limit Threshold of perception ,000 10,000 Changes per minute Figure 7. Typical rule-of-thumb flicker limit curves The guidelines were based on the number of voltage changes per minute (or per second or per hour) and the percentage voltage change. Curves were drawn to show the allowable number of changes of a given magnitude. Figure 7 shows some typical examples of this type of curve. In this figure, the curve labelled IEEE 141 is the Borderline of irritation curve from Figure 3-8 of IEEE 141. The Urban limit and Rural limit are curves historically used by BC Hydro s distribution department. The Threshold of perception curve is taken from the curves shown in the IEC flicker standards. This system, while simple in concept, has several obvious shortcomings. Clearly there are some approximations made in simplifying a series of events (especially complex ones like those shown in Figure 6) into a single magnitude and repetition rate. As we have seen, there are also significant differences in perception for step changes as opposed to gradual changes, so the slope of the transition should also be taken into consideration.
8 8 Another concern is how to combine different components, for example, if you have a large change every 10 seconds and a smaller change every second. There is also the question of how to deal with episodic flicker, where you may have rapid changes for a few minutes once an hour, or once a day. Figure 8. The IEC flicker meter Block 1: Voltage adapter Block 2: Squaring Block 3: Filters Block 4: Square and smooth Block 5: Statistics The IEC flicker meter To address some of these issues, the International Electrotechnical Commission (IEC) introduced standard IEC 868, Flickermeter Block functional 5: Statisticsand design specifications, in The standard defined the design and performance of a measuring instrument for flicker. The intent was for the meter to be used at the lighting location of interest. A block diagram is shown in Figure 8. The IEC flickermeter monitors a single-phase voltage signal, which is passed through rectifier, filter and conditioning circuits to produce a signal proportional to the RMS voltage. This RMS voltage signal is further processed to filter out the base level and measure the amount of voltage variation that is occurring. The voltage variation signal is then passed through a series of filters that approximate the perceptibility curve shown in Figure 2. The resulting output signal is called the instantaneous flicker sensation P, and has a value of 1.0 at the threshold of perceptibility, whatever the flicker frequency. This signal can then be fed to recording, averaging and statistical analysis circuits. The flickermeter standard did not define the statistical analysis to be done, but provided a capability for statistical analysis. Statistical measures of flicker In 1991 the IEC issued standard 868-0, Flickermeter part 0: Evaluation of flicker severity, which defined the statistical analysis and criteria for maximum acceptable flicker levels for a 230 V, 50 Hz system. In this document, a statistical analysis based on a ten-minute sample is used to calculate the parameter P st, the short-term perceptibility index. This index is calculated from a combination of five percentile values, i.e., the P value exceeded 50%, 10%, 3%, 1% or 0.1% of the time during the ten minutes. In this case, a value of 1.0 for the P st index represents the level at which flicker is seen as annoying by most observers. Below that level, there may be times when flicker is perceptible, but it should be rare enough that it is not annoying. In cases where the flicker has a large long-term variability, sampling can be done over an appropriate long interval, and the series of P st values can be averaged using a cube law average (i.e., cube, then average, then take the cube root). This ensures that occasional intervals of annoying flicker are given appropriate weighting. Present-day standards In 1994 the IEC reorganized the flicker standards into IEC and The basic content of the standards has not changed, but the standards have been updated and the numbering has been revised to conform to the overall IEC numbering scheme and fit in with other power quality standards. The IEEE has two standards that deal with flicker, IEEE 141 and IEEE 519, but they are moving to adopt standards compatible with IEC. IEEE task force P1453 has
9 9 developed a flickermeter definition appropriate to 120 V, 60 Hz systems, and is currently working on adopting a standard compatible with the IEC. The IEC is working on changes to incorporate 120 V, 60 Hz systems. Flicker source identification When light flicker occurs, one of the challenges is to identify the source of the flicker so that corrective action can be taken. In some cases there may be only a single large fluctuating load, and the source of the flicker will be obvious, but in other cases there may be multiple large loads connected to a line on which flicker is observed. In this case, conventional flicker measurement techniques have little to offer, but advanced methods can provide a solution. If a monitor that can measure currents as well as voltages is installed, the current drawn by each load can be monitored along with the line voltage. After recording one or two major load changes, the line voltage can be plotted against load current. The source impedance can then be calculated, i.e., the change in voltage per amp of load change. Once this is done, the voltage fluctuation caused by that customer can be calculated from the load current variations. By comparing the calculated fluctuation with the measured fluctuation, a direct measurement can be made of the percentage of the total fluctuation due to the customer being monitored, as shown in Figure 9. In a complicated system, each customer can be monitored either in turn or simultaneously, and the contribution of each load to the flicker can be determined, so that appropriate measures can be taken. This technique provides an additional benefit: proposed changes to the supply or the load can be evaluated. Load current variations multiplied by the impedance provide an estimate of the resulting flicker levels. Changes to the supply system will change the source impedance in a predictable way, and the impact of those changes on the voltage fluctuation can be predicted, taking into account measured load current variations. Recording currents along with voltages gives the system designer a whole new set of tools to use in dealing with flicker. Figure 9 shows some sample voltage and current waveforms and how they can be used to separate internal from external disturbances External disturbances Voltage Current Time (s) Figure 9. Flicker source identification waveforms What you can do to reduce flicker As described in the section on how flicker is produced, load changes have the greatest impact on the voltage in their immediate vicinity. In consequence, the first electricity customer to suffer from voltage flicker is often the customer whose load is causing the flicker. As a rule of thumb, for typical source impedance at the customer panel in the range of 5% to 10%, a load change of about 10% of the panel rating will cause visible light flicker. For a residential customer with a 100 A service, load changes of around 10 A, or 1 kw, would qualify, while for industrial or commercial customers the level increases in proportion to their total load. If repetitive load changes of this magnitude occur, you are likely to suffer annoying flicker levels. The visible flicker level is determined by the magnitude of load changes as well as the source impedance in common between the changing load and the lighting circuit. If you are suffering from local flicker, therefore, you have three basic strategies to choose from: reducing the load changes, reducing the source impedance, or decoupling the load from lighting circuits.
10 10 Reducing the load changes Flicker magnitude is influenced by three characteristics of the load changes: the magnitude, the speed of the change, and the repetition rate. You may be able to control any or all of these to reduce the impact of the flicker. It is sometimes possible to split up a large load, thus reducing the magnitude and/or speed of the change. For example, a large compressed air bank might have three motors, all controlled by the same pressure switch so that they start and stop together. By simply changing to three independent pressure switches, set at slightly different points, the starts and stops can be staggered, substantially reducing the resulting flicker. Similar strategies can be used for many loads like heaters, refrigerators, pumps and compressors, which are not time-critical. In some cases it may be difficult or costly to break up the load, but in other cases a small investment in controls may provide a substantial benefit in flicker reduction. Some of these strategies can pay off in conservation as well, running only a portion of the load unless the full power is needed, and thus reducing the losses. Other options include using soft-starters, reduced-voltage starting of motors or installing variable speed drives with slow starting ramps. With a manufacturing process, it may be possible to slow or stagger the process start through simple program changes. Reducing the source impedance For most low-voltage equipment, the majority of the source impedance is in the service drop, stepdown transformer and low-voltage wiring. If long distances are involved, the voltage drop in the low-voltage wiring can be substantial, and you might consider increasing the conductor size, which will not only reduce fluctuation on loads sharing those conductors, but will also reduce losses and result in some energy savings. The transformer impedance depends mainly on the size of the transformer, so the higher the transformer rating, the less flicker a connected load will produce on the secondary side of the transformer. In some cases it may be appropriate to change transformers, or switch loads between transformers, to minimize flicker. In general, the higher the voltage, the lower the effective impedance, so there may be cases where increasing distribution or end-use voltage will provide an effective remedy. Reducing the coupling The flicker induced in a light source by a changing load depends on the impedance that the two loads share. Often the simplest solution to local flicker, or even to area flicker, is to change the source connections for the lighting load. Industrial and commercial sites often have several supply transformers, which allows for some flexibility. If the site has one large fluctuating load, feeding that load from a dedicated transformer, or at least removing all lighting loads from that transformer, can eliminate or greatly reduce flicker. The worst case of lighting loads connected to the same circuit as the fluctuating load should definitely be avoided, and lighting circuits should be powered from a flicker-free circuit or transformer whenever possible. Another possibility is changing phases, since most lighting is single phase. Simply changing phases to a phase with a smaller variable load may reduce flicker problems substantially in some cases. Lighting changes Occasionally, flicker can be perceived because the type of lighting used is especially sensitive to voltage fluctuations. If other remedies are very expensive and the area of flickering lights is limited, then changing the type of lighting could be explored. Perhaps the most sensitive type of lighting is incandescent lighting on a common thyristor-based dimmer switch. If reduced lighting levels are desired, sometimes staged or blocked fluorescent lighting can achieve the same effect as incandescent light dimming. Active countermeasures Recent advances in power electronics have led to the availability of several different brands of static voltage compensators (SVC). These devices use solid-state switching of inductors or capacitors to
11 11 rapidly compensate for changing line load, thus stabilizing the distribution voltage. The principle is the same as with switchable line compensation capacitors or tap changers, but they operate quickly enough to reduce voltage flicker substantially. These compensators are expensive, but they may provide a cost-effective alternative to upgrading lines when simpler remedies fail. Figure 10 shows an example. In addition to reducing flicker, static voltage compensators have been reported to improve productivity of an arc furnace by 15% to 17% by supplying energy to the arc so that quicker, more efficient melts occur. This increase in productivity typically pays for the SVC in less than two years. A number of large electrical equipment companies manufacture flicker compensators. At present these include the ABB Statcom, the Mitsubishi D-Statcom, and the Siemens Dstatcom. Experience with these devices is limited, but a number of prototype installations have been in service for up to a few years. If the maximum voltage change (excluding infrequent events) is less than 0.2%, it is unlikely that any visible flicker will occur. If large voltage changes can occur, the situation should be reviewed by BC Hydro staff or consultants to determine more accurately whether flicker problems are likely. If so, remedial measures can be implemented, and the costs can be properly assessed against the new load. Following this process, you can make informed decisions about the cost and benefits of the new load, and, with BC Hydro, you can devise the most effective means of avoiding flicker problems Compensator turned on Difference Voltage Current Current Voltage dips reduced & smoothed Time (s) Figure 10. The effect of active compensation Planning ahead to avoid flicker The most cost-effective way of dealing with flicker is to avoid it in the first place. Anytime large variable loads are added to a distribution line, there is a potential for flicker. A new load of this magnitude usually requires consultation with BC Hydro prior to installation, and that is the ideal time to identify and deal with potential flicker problems. The first level of screening is to look at the magnitude of voltage change that can occur due to load variation. This is determined by multiplying the load change by the source impedance.
12 12 References A number of publications are available containing more detailed information on flicker. The most definitive information is in the standards listed below. There are also several textbooks and handbooks available through the IEEE web site. The article Voltage and Lamp Flicker Issues, available on the web, contains an excellent technical review of the issues involved in applying the IEC standards in a North American context. Anyone interested in becoming involved in the process should visit the IEEE task force website and contact a member of IEEE task force P1453 for further information. Websites IEC home page: IEEE home page: IEEE task force home page: grouper.ieee.org/groups/1453 Acknowledgement This brochure was adapted from material originally published by the Power Quality Service Center, Portland, Oregon, and is used under licence. Legal notice This work has been prepared by Performance Energy Partnership, Inc. (PEP) and Ferraro, Oliver & Associates, Inc. (FOA) under contract with Northwest Power Quality Service Center (NWPQSC) and modified by BC Hydro. Neither PEP, FOA, NWPQSC, BC Hydro nor any person on behalf of any of them makes any warranty with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Neither BC Hydro nor Northwest Power Quality Service Center (including its dealers or distributors) shall be liable to the purchaser or any other person or entity with respect to any liability, loss or damage caused or alleged to be caused directly or indirectly by this manual. Northwest Power Quality Service Center and BC Hydro shall not be liable for errors contained herein or for incidental consequences damages in connection with the furnishing, performance or use of this material. Handbooks IESNA Lighting Handbook 9th Edition, Illuminating Engineering Society, 2000 Articles S.M. Halpin, R. Bergeron, T. Blooming, R.F. Burch, L.E. Conrad, T.S. Key, Voltage and Lamp Flicker Issues: Should the IEEE Adopt the IEC Approach?, M. Sakulin and T.S. Key, UIE/IEC Flicker Standard for Use in North America: Measuring Techniques and Practical Applications, Proceedings of PQA 97, March 1997, Columbus OH. G.F. Reed, M. Takeda, J.E. Greaf, T. Aritsuka, T. Matsumoto, Y. Hamasaki, Y. Yonehata, A.P. Sidell, R.E. Chervus, Application of a 5 MVA, 4.16 kv D-Statcom system for voltage flicker compensation at Seattle Iron & Metals, IEEE Summer Power Meeting, July 2000 For more information contact: Your Key Account Manager Phone: Lower Mainland , other areas Fax: A04-587h March 2005 This brochure was printed on an environmentally friendly paper, made from 100% post-consumer waste and processed chlorine free. Please recycle.
Power Quality Centre VOLTAGE FLUCTUATIONS IN THE ELECTRIC SUPPLY SYSTEM. Technical Note No. 7 August 2003
Technical Note No. 7 August 2003 Power Quality Centre VOLTAGE FLUCTUATIONS IN THE ELECTRIC SUPPLY SYSTEM This Technical Note discusses voltage fluctuations, their causes and adverse effects, what levels
Introduction. Harmonics and IEEE 519 Page 1 of 19
Introduction In an ideal power system, the voltage supplied to customer equipment, and the resulting load current are perfect sine waves. In practice, however, conditions are never ideal, so these waveforms
POWER QUALITY IN YOUR HOME
POWER QUALITY IN YOUR HOME How to ensure the life and reliable operation of your home electronics Electricity provides the power you need to run your home electronic equipment. Sometimes, interference
Fundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
EET272 Worksheet Week 9
EET272 Worksheet Week 9 answer questions 1-5 in preparation for discussion for the quiz on Monday. Finish the rest of the questions for discussion in class on Wednesday. Question 1 Questions AC s are becoming
General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System
General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System Direction Planification des actifs et expertise de transport February 2011 TABLE OF CONTENTS 1. CONDUCTING
LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE
LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE Karl M. Hink, Executive Vice President Originally presented at the Power Quality 99 Conference ABSTRACT Motor protection
Power Quality Standards for Electric Service
Power Quality Standards for Electric Service Effective June 1, 2008 A transition period will exist from June 1 through December 31, 2008 in which installations may be approved and connected as long as
SECTION DVD01: VOLTAGE DROP/VOLTAGE FLICKER AND TRANSFORMER SIZING GUIDELINES
Issued 06-01-07 DESIGN Section DVD00 INFORMATION SECTION Page 1 of 1 INDEX SECTION DVD01: VOLTAGE DROP/VOLTAGE FLICKER AND TRANSFORMER INTRODUCTION... Page 2 LOAD ESTIMATING AND TRANSFORMER SIZING GUIDELINES...Page
Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1
Experiment no 1 Power measurement in balanced 3 phase circuits and power factor improvement 1 Power in Single Phase Circuits Let v = m cos(ωt) = cos(ωt) is the voltage applied to a R-L circuit and i =
Nuclear Power Plant Electrical Power Supply System Requirements
1 Nuclear Power Plant Electrical Power Supply System Requirements Željko Jurković, Krško NPP, [email protected] Abstract Various regulations and standards require from electrical power system of the
Power Quality for Information Technology System
Power Quality for Information Technology System ITS OBVIOUS THE TOLERANCE IS DIFFRENT But What isn t Tobvious? HOW MANY OF YOU HAVE : A COMPUTER AT HOME? = Computers are not screens and Keyboards COMPUTERS
Power System review W I L L I A M V. T O R R E A P R I L 1 0, 2 0 1 3
Power System review W I L L I A M V. T O R R E A P R I L 1 0, 2 0 1 3 Basics of Power systems Network topology Transmission and Distribution Load and Resource Balance Economic Dispatch Steady State System
INTRODUCTION TO SYNCHRONIZING AUTOMATIC SYNCHRONIZING CONSIDERATIONS AND APPLICATIONS
INTRODUCTION TO SYNCHRONIZING AUTOMATIC SYNCHRONIZING CONSIDERATIONS AND APPLICATIONS INTRODUCTION It is the intention of this presentation to provide an explanation of the automatic synchronizing process,
Line Reactors and AC Drives
Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences
FIXED CHARGE: This is a cost that goes towards making the service available, including
ELECTRICITY BILL COMPONENTS FIXED CHARGE: This is a cost that goes towards making the service available, including installation and maintenance of poles, power lines and equipment, and 24-hour customer
AMI and DA Convergence: Enabling Energy Savings through Voltage Conservation
AMI and DA Convergence: Enabling Energy Savings through Voltage Conservation September 2010 Prepared for: By Sierra Energy Group The Research & Analysis Division of Energy Central Table of Contents Executive
Power transformers. Special transformers Railway
Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together
SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS
SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE S By Jack Farrow, May, 2004 WELDING TECHNOLOGY CORPORATION ABSTRACT Information on how to select the correct size of substation transformer and 480V bus to
Power Quality. Uninterruptible Power Supply
Quality Uninterruptible Supply In the electrical system environment, power disturbances will occur. These can be caused by faults on the distribution system, the operation of nearby equipment, lightning
Rotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
Understanding Power Factor, Crest Factor, and Surge Factor. White Paper #17
Understanding Power Factor, Crest Factor, and Surge Factor White Paper #17 Executive Summary This paper explains the technical terms of Power Factor, Crest Factor, and Surge Factor. The use of these terms
ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe
NETWORKS ESB Networks Response to ERGEG Consultation on Voltage Quality Regulation in Europe Date: 22 February 2007 Distribution System Operator ESB Networks Page 1 of 12 Contents 1.0 INTRODUCTION...3
Neutral Currents in Three Phase Wye Systems
POWER SYSTEMS ENGINEERING DATA PUBLISHED BY SQUARE D, OSHKOSH, WISCONSIN Subject: Neutral Currents in Three Phase Wye Systems by Robert Arthur Square D Company Oshkosh, Wisconsin (414) 46-80 and R. A.
POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS
A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS By: Robert G. Ellis, P. Eng., Rockwell Automation Medium Voltage Business CONTENTS INTRODUCTION...
HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM
Technical Note No.3 March 2000 HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM This Technical Note discusses harmonic distortion, its causes and adverse effects, what levels are unacceptable and how
Cahier technique no. 196
Collection Technique... Cahier technique no. 196 Integration of local power generation in industrial sites and commercial buildings T. Hazel "Cahiers Techniques" is a collection of documents intended for
ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.
POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
Voltage Tolerance Boundary
Pacific Gas and Electric Company Voltage Tolerance Boundary The only national standard for utilization voltage regulation is ANSI C84.1. Its title is American National Standard for Electric Power Systems
Product Data Bulletin
Product Data Bulletin Power System Harmonics Causes and Effects of Variable Frequency Drives Relative to the IEEE 519-1992 Standard Raleigh, NC, U.S.A. INTRODUCTION This document describes power system
Equipment Performance Due to Voltage Sags Test Results for Contactor and Induction Motor
DOI 10.7603/s40707-013-0008-5 Equipment Performance Due to Voltage Sags Test Results for Contactor and Induction Motor Surya Hardi, Muhd. Hafizi, Muzamir Isa, Rohana Ismail Abstract This paper presents
Modeling and Simulation of a Large Chipper Drive
The Open Electrical & Electronic Engineering Journal, 009, 3, 1-8 1 Modeling and Simulation of a Large Chipper Drive Open Access Christian Kral, Anton Haumer, Hansjörg Kapeller and Gert Pascoli Austrian
Power Quality. Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost
Power Quality Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost A voltage sag is defined as a decrease in voltage magnitude below 90% of nominal, but not a complete interruption. The typical
The electrical energy produced at the gen
300 300 Principles of Power System CHAPTER CHAPTER 12 Distribution Systems General 12.1 Distribution System 12.2 Classification of Distribution Systems 12.3 A.C. Distribution 12.4 D.C. Distribution 12.5
= V peak 2 = 0.707V peak
BASIC ELECTRONICS - RECTIFICATION AND FILTERING PURPOSE Suppose that you wanted to build a simple DC electronic power supply, which operated off of an AC input (e.g., something you might plug into a standard
Power Supplies. 1.0 Power Supply Basics. www.learnabout-electronics.org. Module
Module 1 www.learnabout-electronics.org Power Supplies 1.0 Power Supply Basics What you ll learn in Module 1 Section 1.0 Power Supply Basics. Basic functions of a power supply. Safety aspects of working
Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power
App Notes ~ Outdoor Power System Design and Cost Considerations 1 Authors Peter Nystrom President TSi Power Corp. Coordination of Telecommunications Surge Protective Devices in Countries with Unstable
Power Quality Issues, Impacts, and Mitigation for Industrial Customers
Power Quality Issues, Impacts, and Mitigation for Industrial Customers By Kevin Olikara, Power and Energy Management Products Rockwell Automation, Inc. Now, more than ever, electronic equipment and computing
Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies
Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the
Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION
Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION Outline What is Reactive Power and where does it come from? Why is it important?
Electrical Resonance
Electrical Resonance (R-L-C series circuit) APPARATUS 1. R-L-C Circuit board 2. Signal generator 3. Oscilloscope Tektronix TDS1002 with two sets of leads (see Introduction to the Oscilloscope ) INTRODUCTION
Charger Output AC Ripple Voltage and the affect on VRLA batteries
TECHNICAL BULLETIN 41-2131 Charger Output AC Ripple Voltage and the affect on VRLA batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products.
Voltage Drop. Voltage Drop 1
Voltage Drop The technical information provided herein is to assist qualifi ed persons in planning and installing electric service to farms and residences. Qualified person is defi ned in Article 100 of
POWER AND VOLTAGE RATING
POWER AND VOLTAGE RATING SCOPE: The purpose of this document is to take the confusion out of power and voltage ratings in specifications and in product information publications. This will be accomplished
Motor Protection Voltage Unbalance and Single-Phasing
Motor Protection Voltage Unbalance and Single-Phasing Cooper Bussmann contributes the following information, which is an excerpt from their 190-page handbook SPD Selecting Protective Devices Based on the
Iron Powder Cores for Switchmode Power Supply Inductors. by: Jim Cox
HOME APPLICATION NOTES Iron Powder Cores for Switchmode Power Supply Inductors by: Jim Cox Purpose: The purpose of this application note is to cover the properties of iron powder as a magnetic core material
Three phase circuits
Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors
STANDARD SUPPLY CONDITIONS FOR SPECIFIED POWER DEMAND
STANDARD SUPPLY CONDITIONS FOR SPECIFIED POWER DEMAND NOTICE This is unofficial English translation of KYEPCO s STANDARD SUPPLY CONDITIONS FOR SPECIFIED POWER DEMAND ( tokutei kibo juyo hyojun kyokyu joken
S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information
Description Features The S112-X is a bi-directional, single-pole, single-throw, normally open multipurpose solid-state relay. The circuit is composed of one input IR LED with a series limiting resistor
Variable Frequency Drives - a Comparison of VSI versus LCI Systems
Variable Frequency Drives - a Comparison of VSI versus LCI Systems Introduction TMEIC is a leader in the innovative design and manufacture of large ac variable f requency drive systems. TMEIC has been
Touch Tone Controller. Model TR16A. Owner s Manual
Touch Tone Controller Model TR16A Owner s Manual CONTENTS IMPORTANT NOTICE Features... 2 Introduction... 2 Important Notice...3 How it Works... 4 Installation... 4 Operation a... 5 From the Touch Tone
Technical Comparison of On-line vs. Line-interactive UPS designs
Technical Comparison of On-line vs. Line-interactive UPS designs By Jeffrey Samstad Michael Hoff White Paper #79 Executive Summary UPS systems below 5000VA are available in two basic designs: line-interactive
Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.
By Darrell G. Broussard, P.E. Introduction: As engineers, we are aware that electrical power systems have grown. How much have they grown? When was the last time you specified a 2400-volt system, a 4160-volt
PowerFlex Dynamic Braking Resistor Calculator
Application Technique PowerFlex Dynamic Braking Resistor Calculator Catalog Numbers 20A, 20B, 20F, 20G, 22A, 22B Important User Information Solid-state equipment has operational characteristics differing
FULL ELECTRICAL LNG PLANTS: HIGHEST AVAILABILITY AND ENERGY EFFICIENCY THROUGH OVERALL SYSTEM DESIGN
FULL ELECTRICAL LN PLANTS: HIHEST AVAILABILITY AND ENERY EFFICIENCY THROUH OVERALL SYSTEM DESIN Dr. Edwin Lerch Siemens A Infrastructure and Cities Sector, IC S SE PTI, ermany Phone: 49-9131-7-34052 Fax:
Objectives. Electric Current
Objectives Define electrical current as a rate. Describe what is measured by ammeters and voltmeters. Explain how to connect an ammeter and a voltmeter in an electrical circuit. Explain why electrons travel
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
Supply Standards: Electricity Supply Standard July 2011 4 JULY 2011 ISSUE 6 UNCLASSIFIED UNCONTROLLED COPY IF PRINTED
s: Electricity Supply Standard July 2011 4 JULY 2011 ISSUE 6 OPERATIONAL PROCEDURE - s: Electricity PREPARED BY: Power Quality Manager AUTHORISED BY: General Manager Network Support DOCUMENT NUMBER: -
FILM CAPACITORS FOR ELECTRONIC LIGHTING
1. Introduction: FILM CAPACITORS FOR ELECTRONIC LIGHTING G. Schabbach, Dr. K. Weigel, Dr. G. Zimmermann EPCOS AG Fluorescent lamps have emerged as the preferred light source for industrial and domestic
Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.
Power Electronics Prof. K. Gopakumar Centre for Electronics Design and Technology Indian Institute of Science, Bangalore Lecture - 1 Electric Drive Today, we will start with the topic on industrial drive
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES WHITE PAPER: TW0062 36 Newburgh Road Hackettstown, NJ 07840 Feb 2009 Alan Gobbi About the Author Alan Gobbi Alan Gobbi
Facilities. Facility Power Monitoring: Or, Where Did All the Electrons Go? Technology & Development Program. Permanent and Temporary Metering
Facilities United States Department of Agriculture Forest Service Technology & Development Program February 2007 7300 0773-2309 Facility Power Monitoring: Or, Where Did All the Electrons Go? Ted Etter,
CO-ORDINATION OF PARALLEL AC-DC SYSTEMS FOR OPTIMUM PERFORMANCE
CO-ORDINATION OF PARALLEL AC-DC SYSTEMS FOR OPTIMUM PERFORMANCE Ana Diez Castro & Rickard Ellström Ying Jiang Häfner Christer Liljegren Vattenfall Utveckling AB ABB Power Systems Gotlands Energiverk AB
Short Circuit Current Calculations
Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that
Starting Current Reduction of Residential HVAC System and Peak-Load Impact of Power System: A Case Study
Starting Current Reduction of Residential HVAC System and Peak-Load Impact of Power System: A Case Study By Paul I-Hai Lin Professor of Electrical and Computer Engineering Technology P.E. (State of Indiana
FACTS. Solutions to optimise network performance GRID
Solutions to optimise network performance GRID Solutions to optimise your network Our worldwide presence: Better solutions for your network all around the world Tampere Philadelphia Stafford Konstanz Beijing
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education
Rule 5.500 Fast Track Analysis for National Life Insurance Co.
Rule 5.500 Fast Track Analysis for National Life Insurance Co. For a 500 kw Solar array to be located at 155 Northfield Street in Montpelier, Vermont Green Mountain Power Pam Allen Date: 5/31/13 SECTION
SYNCHRONOUS MACHINES
SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical
The design and performance of Static Var Compensators for particle accelerators
CERN-ACC-2015-0104 [email protected] The design and performance of Static Var Compensators for particle accelerators Karsten Kahle, Francisco R. Blánquez, Charles-Mathieu Genton CERN, Geneva, Switzerland,
AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN
AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN By Joe Randolph Introduction The conventional 2-wire analog phone line that telephone companies provide to residential
Power Quality & Custom Power
Day-3 Power Quality & Custom Power Arindam Ghosh Dept. of Electrical Engineering Indian Institute of Technology Kanpur,, India E-mail: aghosh@iitk iitk.ac.in Power Quality (PQ) The term electric power
The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies
The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies DATE: November 17, 1999 REVISION: AUTHOR: John Merrell Introduction In some short circuit studies, the X/R ratio is ignored when comparing
Impact of Leading Power Factor on Data Center Generator Systems
Impact of Leading Power Factor on Data Center Generator Systems White Paper 200 Revision 0 by Neil Rasmussen Executive summary IT devices may exhibit electrical input current with a characteristic called
For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz)
24 1. NETWORK CONFIGURATIONS definition Standard IEC 38 defines voltage ratings as follows: - Low voltage () For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690
Power surges can also be generated by equipment in your facility such as:
Power Quality Surge Suppressors What is Surge Protection A surge suppressor can be the first and best defense against the instant or gradual destruction of electrical equipment. Compared to the replacement
AMZ-FX Guitar effects. (2007) Mosfet Body Diodes. http://www.muzique.com/news/mosfet-body-diodes/. Accessed 22/12/09.
Pulse width modulation Pulse width modulation is a pulsed DC square wave, commonly used to control the on-off switching of a silicon controlled rectifier via the gate. There are many types of SCR s, most
Automatic Dropout Prevention Enables Current Sink Backlighting for High-End Handheld Devices
Automatic Dropout Prevention Enables Current Sink Backlighting for High-End Handheld Devices By Tom Karpus and Karl Volk Director, Handheld Applications and Systems Engineering and Director of Marketing
Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka
Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka S S B Udugampala, V Vijayarajah, N T L W Vithanawasam, W M S C Weerasinghe, Supervised by: Eng J Karunanayake, Dr. K T M U Hemapala
7. Reactive energy compensation
593 7. Reactive energy compensation 594 7. REACTIVE ENERGY COMPENSATION Reactive energy compensation is an important element for reducing the electricity bill and improving the quality of the electrical
Integration of Distributed Generation in the Power System. IEEE Press Series on Power Engineering
Brochure More information from http://www.researchandmarkets.com/reports/2171489/ Integration of Distributed Generation in the Power System. IEEE Press Series on Power Engineering Description: A forward
COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS
COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS Afshin LASHKAR ARA Azad University of Dezfoul - Iran [email protected] Seyed Ali NABAVI NIAKI University of Mazandaran
How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse
How the National Grid System Operates Chris Gorman Lead Account Executive Syracuse 2 Parts of the Electric System Parts of the Electric System 1. Generating Station: Produces Electricity. 2. Transmission
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Energy Saving systems for Induction motors.
Energy Saving systems for Induction motors. Are they a sham? Do they work? There seems to be a resurgence in interest in the Nola energy saving algorithm for induction motors, with a number of manufacturers
Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49
Circuits with inductors and alternating currents Chapter 20 #45, 46, 47, 49 RL circuits Ch. 20 (last section) Symbol for inductor looks like a spring. An inductor is a circuit element that has a large
Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015
Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) The standard tuning values used in ADVANCED Motion Controls drives are conservative and work well in over 90%
IEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays
IEC 00-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays Application Note July 1999 AN9612.2 Author: Wayne Austin The SP720, SP721, SP723, and SP724 are protection
Transfer Equipment Controls
Control Types Manual Transfer Switches Nonautomatic Transfer Switches Automatic Transfer Switches The type of control system for the transfer switch will vary depending on the type of switching equipment
E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.
SAFETY Industrial DESCRIBE hazards and precautions taken to avoid injury in the workplace. Example #1: All of the following are common PPE used to perform maintenance activities EXCEPT: a. Safety Glasses
APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.
TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION Abstract This application note describes the four quadrant mode of operation of a linear AC Power
ENERGY AND ENVIRONMENTAL SAVINGS IN STEEL MAKING BY MEANS OF SVC LIGHT
ENERGY AND ENVIRONMENTAL SAVINGS IN STEEL MAKING BY MEANS OF SVC LIGHT Rolf Grünbaum, Tomas Gustafsson ABB Power Systems AB AC Systems Division SE-721 64 Vasteras Sweden Phone: +46 21 32 40 00 rolf.grunbaum,
Connection of micro-generation to the electricity distribution network
Connection of micro-generation to the electricity distribution network Network recommendation YA9:09 Sivu 1(20) CONTENTS INTRODUCTION...3 1. MARKINGS AND DEFINITIONS...3 2. DEFINITION OF MICRO-GENERATION
Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE
Understanding Power Factor and How it Affects Your Electric Bill Presented by Scott Peele PE Understanding Power Factor Definitions kva, kvar, kw, Apparent Power vs. True Power Calculations Measurements
Interference in the ECG and its elimination
Interference in the ECG and its elimination General points The signal voltages in ECG recording are known to be very small and are in the millivolt range, i.e. they have amplitudes of only a few thousands
Flicker happens. But does it have to?
Flicker happens. But does it have to? Introduction Nearly all AC-powered traditional light sources exhibit some degree of periodic modulation or flicker. The effects of undesired flicker from artificial
Electronics for Analog Signal Processing - II Prof. K. Radhakrishna Rao Department of Electrical Engineering Indian Institute of Technology Madras
Electronics for Analog Signal Processing - II Prof. K. Radhakrishna Rao Department of Electrical Engineering Indian Institute of Technology Madras Lecture - 18 Wideband (Video) Amplifiers In the last class,
Guidelines for ATS selection: How to choose the right transfer solution for your power application.
Power topic #7012 Technical information from Cummins Power Generation Inc. Guidelines for ATS selection: How to choose the right transfer solution for your power application. > White Paper By Gary Olson,