Pressure Independent Characterized Control Valves (PICCV)
|
|
|
- Marjory McCarthy
- 10 years ago
- Views:
Transcription
1 Pressure Independent haracterized ontrol s (PIV) Easy direct coupling of actuator with a single screw. Perpendicular mounting ISO flange and square drive head eliminate lateral forces on the stem. Vent holes reduce condensation build-up. Regulator helps maintain constant differential pressure across ball. ouble EPM O-Ring design for long service life. Blow-out proof stem with thrust-bearing Teflon disc offering sturdy construction. Self cleaning ball seat design increases life and longevity of the valve. Nickle plated body reduces corrosion and stress concentration. ownstream low pressure PT port. Upstream high pressure PT port. Forged brass valve body. Regulator assembly built to last. Optional PT ports Integral PT ports on ½ and ¾ models. External union with PT ports on 1 through 2 PIV models. Equal percentage characterizing disc provides excellent control and reliability. ynamic pressure regulator assembly with stainless steel, brass, components and resilient polymer diaphragm. isadvantages of Today s Systems Time consuming balancing effort Rebalancing required when adding to system or remodeling Poor valve authority at average or low load Balancing procedure dictates quality Low ΔT at the coils yields overflow and increases pumping costs Potential spreading of control problems can occur when one or more loops are instable, due to interactive nature of circuits Low ΔT at the coil yields overflow and increases pumping costs. Features Advantages of the PIV Easy selection, no v calculation required Hydronic balancing is simplified, as the circuits are not interactive Flexible commissioning One piece installation saves 50% of labor costs, installation space, and investment for balancing valve Reduces pumping costs by maintain flow regardless of pressure fluctuations Visualizes fl ow in a BMS system and provides accurate fl ow for each degree of opening Prevents overfl ow or underfl ow for fast start-up Options Automatic dynamic system balancing Field adjustable fl ow rate 5 50 PSI differential pressure operating range (gradual fl ow will increase from 0-5 psi) GPM (½ 2 ) 5 year warranty Belimo P-Tool/ZTH-GEN US for commissioning Weather shields Auxiliary switches Flow verification orifi ce (-F models) available only with field set LRB24-SA and KRB24-3 Tefl on and Tefzel are registered products of upont
2 Set-up Pressure Independent haracterized ontrol s (PIV) SET-UP 2-WAY VALVE SPEIFY UPON ORERING NON-SPRING RETURN Stays in Last Position LRB24-3, KRB24-3 Floating type actuators LRX24-MFT ARX24-MFT MFT type actuators* N: Normally losed- Factory default with the directional switch in the 1 positon. Power to pin 2 will drive valve W. Power to pin 3 will drive valve W. N: Normally losedvalve will open as voltage increases. Actuator switch on Y2. NO: Normally Open- LRB Only- hange directional switch from default 1 position to the 0 postion. NO: Normally Openvalve will close as voltage increases. Actuator switch on Y1. LRB24-SA N ONLY: Normally losed-valve will open as voltage increases. Actuator switch on Y2 SPRING RETURN Note Fail Position LF24-MFT US AFRX24-MFT MFT type actuators TFRX24-MFT N/FO : Normally losed-valve will open as voltage increases. Actuator switch on W. Spring Action: Will fail open upon power loss. N/FO : Normally losed-valve will open as voltage increases. Switch on (arrow setting) Spring Action: Will fail open upon power loss. INSTALLATION PIVs should be installed with fl ow in the direction of the arrow on the valve body. If installed backwards, there could be damage age to either the diaphragm or the regulator. The valve assembly can be installed in a vertical or horizontal arrangement, as long as the actuator is positioned to avoid condensation from dripping on the actuator. N/F : Normally losed-valve will open as voltage increases. Actuator switch on W. Spring Action: Will fail closed upon power loss. N/F : Normally losed-valve will open as voltage increases. Switch on (arrow setting) Spring Action: Will fail closed upon power loss. *The design flow rate of PIVs with MFT actuators are dependent on their Minimum and Maximum Percentages of rotation. Actuators must be re-programmed for different Minimum and Maximum Settings if actuator set-ups must be changed. Please refer to PIV online technical documentation, MFT Adjustment Tables, for re-programming the settings. NO/F : Normally Open-valve will close as voltage increases. Actuator switch on W. Spring Action: Will fail closed upon power loss. NO/F : Normally Open-valve will close as voltage increases. Switch on (arrow setting) Spring Action: Will fail closed upon power loss. NO/FO : Normally Open-valve will close as voltage increases. Actuator switch on W. Spring Action: Will fail open upon power loss. NO/FO : Normally Open-valve will close as voltage increases. Switch on (arrow setting) Spring Action: Will fail open upon power loss. 2
3 Operation / Installation Pressure Independent haracterized ontrol s (PIV) FLOW PATTERN PIV consists of a differential pressure regulator in series with a control valve. The control valve is throttled to match the fl ow command of the control signal. The differential pressure regulator holds the pressure drop across the ball of the valve. As system pressures change, the differential pressure regulator moves in response to keep the fl ow stable. Regulator Section ontrol Section Water exits valve pressure is P3 (low). Pressure P1 at the inlet of the PIV is high and pressure P3 at the outlet is low. The differential pressure between P1 and P3 must be between 5-50 PSI to achieve pressure independent fl ow. When differential pressure increases the regulator opening is reduced. When differential pressure decreases the regulator opening is increased. This allows for the constant pressure differential across the ball of the valve. P1- Upstream pressure P2 entering valve. P1 P3 P3 P3 P3 is downstream of the ball as well as below diaphgram. P1 is upstream. Low pressure pulls regulator down against the spring force. THE BEST WAY TO ONTROL FLOW Maintain design fl ow independent of pressure variations. The PIV is a two-way valve that will supply a specific flow for each degree of ball opening regardless of pressure variations in a system. Accuracy 3
4 Piping the PIV to Achieve a Larger Flow Rate The Pressure Independent haracterized ontrol s can be piped in a parallel orientation to achieve increased flow rates. PIVs are available in flow values from 0.5 to 100 GPM. To achieve higher flows, it is recommended to pipe the two valves in parallel. To correctly operate these valves, the Belimo Multi Function Technology (MFT) will be employed to utilize one common control signal. This recommended configuration provides the control of flows up to 200 GPM by using two valves. The top diagram details valves piped in a parallel arrangement. The bottom diagram features a typical single piping arrangement. If more than three valves are piped in parallel, please call Belimo to discuss control options. TYPIAL PARALLEL PIPING IN RELATION TO THE INPUT AN OUTPUT (SALE: NONE) BELIMO PIV (TYP.) PARALLEL PIPING ARRANGEMENT FOR PIV H/ OIL PT PORT FLOW PT PORT PT PORT FLOW TEE (TYP.) AIR VENT FLOW PT PORT PT PORT FLOW SHUT OFF VALVE UNION ONNETION (TYP.) FLOW RAIN PT PORT FLOW TYPIAL PIPING IN RELATION TO THE INPUT AN OUTPUT (SALE: NONE) H/ OIL AIR VENT FLOW BELIMO PIV (TYP.) PT PORT STRAINER (Optional) PT PORT FLOW TYPIAL PARALLEL PIPING IN RELATION TO THE INPUT AN OUTPUT FLOW SHUT OFF VALVE SHUT OFF VALVE UNION ONNETION (TYP.) FLOW RAIN PT PORT FLOW STRAINER (Optional) FLOW SHUT OFF VALVE USA TYPIAL PARALLEL PIPING ANAA IN RELATION LATIN AMERIA / ARIBBEAN TO THE INPUT AN OUTPUT
5 Nomenclature Pressure Independent haracterized ontrol s (PIV) P B 005 LRX 24 -MFT Type P= Pressure Independent haracterized ontrol Porting 2 = Two Way Body Size 050 = ½ 075 = ¾ Body Type B = hrome Plated Flow Rate 005 =.50 GPM 010 = 1 GPM 015 = 1.5 GPM 020 = 2 GPM 025 = 2.5 GPM 030 = 3 GPM 035 = 3.5 GPM 040 = 4 GPM 045 = 4.5 GPM 050 = 5 GPM 055 = 5.5 GPM 060 = 6 GPM 065 = 6.5 GPM 070 = 7 GPM 075 = 7.5 GPM 080 = 8 GPM 085 = 8.5 GPM 090 = 9 GPM 095 = 9.5 GPM 100 = 10 GPM Options -P = PT Port -F = Flow Orifi ce Actuator Type Non-Spring Return LRB LRX KRB... Spring Return TF LF Power Supply 24 = 24 VA / 120 = 120 VA ontrol -3 = Floating Point -MFT = Multi- Function Technology -SA = Proportional 2-10V Ordering Example 1 hoose the valve actuator combination. P2050B005+LRX24-MFT 2 Specify preference or confi guration. Non-Spring Return Actuator Models NO = Normally Open N = Normally losed Spring Return Actuator Models NO/FO = Normally Open/Fail Open NO/F = Normally Open/Fail losed N/FO = Normally losed/fail Open N/F = Normally losed/fail losed Set-Up Refers to valve ports from inlet to outlet, per fl ow arrow. 3 +N For MFT Orders Only - Select Programming ode +Tagging (if needed) P (A19) P (A19) 2 to 10 V P (A28) 0 to 10 V P (W31) 0.02 to 5.00 seconds PWM P (W32) 0.10 to seconds PWM P (W34) 0.59 to 2.93 seconds PWM P (F03) Floating Point 4 oes order require tagging? Tagging: s may be tagged per customer specifi cation. ($10.00 charge per tag) Example: AHU-1 FU-2 Part number for tagging: omplete Ordering Example: P2050B005+LRX24-MFT+N+A19 5
6 Nomenclature Pressure Independent haracterized ontrol s (PIV) PIV LRX 24 -MFT Pressure Independent haracterized ontrol 2-way hrome Plated Brass Ball and Brass Stem Size 25 = 1 32 = 1¼ 40 = 1½ 50 = 2 Flow Rate 3 GPM Refer to table Options -P = PT Port -F = Flow Orifi ce Actuator Type Non-Spring Return LRB LRX ARX Spring Return TF LF AF Power Supply 24 = 24 VA/ 120 = 120 VA ontrol -3 = Floating Point -MFT = Multi-Function Technology -SA = Proportional 2-10 V S = Built-in Auxiliary Switch Ordering Example 1 hoose the valve actuator combination. PIV LRX24-MFT 2 Specify preference or confi guration. Non-Spring Models NO = Normally Open N = Normally losed Spring Return Models NO/FO = Normally Open/Fail Open NO/F = Normally Open/Fail losed N/FO = Normally losed/fail Open N/F = Normally losed/fail losed Set-Up Refers to valve ports from inlet to outlet, per fl ow arrow. 3 +N For MFT orders only - select programming code +Tagging (if needed) P (A19) P (A19) 2 to 10 V P (A28) 0 to 10 V P (W31) 0.02 to 5.00 seconds PWM P (W32) 0.10 to seconds PWM P (W34) 0.59 to 2.93 seconds PWM P (F03) Floating Point P (A19) On/Off** 4 oes order require tagging? Tagging: s may be tagged per customer specifi cation. ($10.00 charge per tag) Example: AHU-1 FU-2 Part number for tagging: omplete Ordering Example: PIV LRX24-MFT+N+A19 ** Wire for On/Off 6
7 Factory Set Pressure Independent haracterized ontrol s (PIV) Product Range Overview P2..., 2-way Nominal Size Type Suitable Actuators GPM ** Inches 2-way NPT Non-Spring Return Spring Return Models with (-P) have integral PT ports Models with (-P) have external PT ports Forged Body ast Body 0.5 ½ 15 P2050B005 (-P) 1 ½ 15 P2050B010 (-P) 1.5 ½ 15 P2050B015 (-P) 2 ½ 15 P2050B020 (-P) 2.5 ½ 15 P2050B025 (-P) 3 ½ 15 P2050B030 (-P) 3.5 ½ 15 P2050B035 (-P) 4 ½ 15 P2050B040 (-P) 4.5 ½ 15 P2050B045 (-P) 5 ½ 15 P2050B050 (-P) 5.5 ½ 15 P2050B055 (-P) 6 ¾ 20 P2075B060 (-P) 6.5 ¾ 20 P2075B065 (-P) 7 ¾ 20 P2075B070 (-P) 7.5 ¾ 20 P2075B075 (-P) 8 ¾ 20 P2075B080 (-P) 8.5 ¾ 20 P2075B085 (-P) 9 ¾ 20 P2075B090 (-P) 9.5 ¾ 20 P2075B095 (-P) 10 ¾ 20 P2075B100 (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) 18 1¼ 32 PIV (-P) 19 1¼ 32 PIV (-P) 20 1¼ 32 PIV (-P) 21 1¼ 32 PIV (-P) 22 1¼ 32 PIV (-P) 23 1¼ 32 PIV (-P) 24 1¼ 32 PIV (-P) 25 1¼ 32 PIV (-P) 26 1¼ 32 PIV (-P) 26 1½ 40 PIV (-P) 27 1½ 40 PIV (-P) 28 1½ 40 PIV (-P) 29 1½ 40 PIV (-P) 30 1½ 40 PIV (-P) 31 1½ 40 PIV (-P) 32 1½ 40 PIV (-P) 33 1½ 40 PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) LRB24-3 LRX24-MFT ARX24-MFT LRX120-3 LRB24-3 (Heat Pump Only) TFRX24-MFT LF24-MFT US AFRX24-MFT PIV haracteristic Mode of Operation The Pressure Independent haracterized ontrol (PIV) is a two-way valve which combines the functionality of a control valve and a pressure regulating valve, creating one precise product which is unaffected by pressure variations in a system. Product Features onstant fl ow regardless of pressure variations in the system at set degrees of ball opening. Maximizes chiller ΔT, preventing energizing additional chillers due to low ΔT. Simplifi ed valve sizing and selection, no v calculations required. (-P) ΔP verification across valve using PT ports. Actuator Specifications ontrol type -3 on/off, fl oating point -MFT proportional, 2-10 V (confi gurable) Manual override (LRB, LRX, AFRX, ARX) Electrical connection 3 ft. [1m] cable with ½ conduit fitting (additional cable lengths are available) Specifications Service chilled or hot water, 60% glycol max Flow characteristic equal percentage ontrollable flow range 75 Sizes ½, ¾, 1, 1¼, 1½, 2 End fitting NPT female ends Materials Body brass, nickel plated Ball chrome plated brass Stem chrome plated brass Seats ½ and ¾ Teflon PTFE 1 to 2 Tefl on PTFE /Tefzel Seat o-rings Viton haracterizing disc ½ and ¾ brass 1 to 2 Tefzel O-rings EPM (lubricated) iaphragm ½ and ¾ Nomex reinforced silicone 1 to 2 polyester reinforced silicone Regulator components stainless steel/brass/nitrile Spring stainless steel Media temp range 0 F to 212 F [-18 to +100 ] PT Ports optional, ½ to ¾ internal 1 to 2 external (-P) Body pressure rating 600 psi ½, ¾, psi 1¼, 1½, 2 lose off pressure 200 psi ifferential pressure 5 to 50 psid (ΔP) range Leakage ANSI lass IV (0.01% of rated valve capacity at 50 psi differential) Tefzel and Tefl on are registered trademarks of upont 7
8 Field Set Pressure Independent haracterized ontrol s (PIV) Product Range Overview P2..., 2-way Nominal Size Type Suitable Actuators GPM Range Inches 2-way NPT Non-Spring Return 0...( ) ½ 15 P2050B ( ) ½ 15 P2050B ( ) ½ 15 P2050B (5.7-10) ¾ 20 P2075B (11-16) 1 25 PIV (17-21) 1 25 PIV KRB24-3 LRB24-SA PIV haracteristic ΔP verifi cation across valve using PT ports (-P) Nominal Size Type Suitable Actuators GPM Range Inches 2-way NPT Non-Spring Return 0...( ) ½ 15 P2050B010-P 0...( ) ½ 15 P2050B025-P 0...( ) ½ 15 P2050B055-P 0...(5.7-10) ¾ 20 P2075B100-P 0...(11-16) 1 25 PIV P 0...(17-21) 1 25 PIV P Flow verifi cation using ΔP across orifi ce (-F) Nominal Size Type Suitable Actuators GPM Range Inches 2-way NPT Non-Spring Return 0...( ) ½ 15 P2050B010-F 0...( ) ½ 15 P2050B025-F 0...( ) ½ 15 P2050B055-F 0...(5.7-10) ¾ 20 P2075B100-F 0...(11-16) 1 25 PIV F 0...(17-21) 1 25 PIV F KRB24-3 KRB24-3 LRB24-SA LRB24-SA Mode of Operation The Pressure Independent haracterized ontrol (PIV) is a two-way valve which combines the functionality of a control valve and a pressure regulating valve, creating one precise product which is unaffected by pressure variations in a system. Product Features Once field set the valve will provide constant flow regardless of pressure variations in the system at set degrees of ball opening. Maximizes chiller ΔT, preventing energizing additional chillers due to low ΔT. Simplifi ed valve sizing and selection, no v calculations required. (-P) ΔP verification across valve using PT ports. (-F) Flow verification using ΔP across orifice. is supplied at maximum fl ow in the full open position only. Field adjustment is necessary to achieve lower flow. Actuator Specifications ontrol type on/off, fl oating point Manual override KRB, LRB...-SA Electrical connection 3 ft. [1m] cable (no conduit on KR) ½ conduit fi tting on LR only Specifications Service chilled or hot water, 60% glycol max Flow characteristic equal percentage ontrollable flow range 75 Sizes ½, ¾, 1 End fitting NPT female ends Materials Body brass, nickel plated Ball chrome plated brass Stem chrome plated brass Seats ½ and ¾ Tefl on PTFE 1 Tefl on PTFE /Tefzel Seat o-rings Viton haracterizing disc ½ and ¾ brass 1 Tefzel O-rings EPM (lubricated) iaphragm ½ and ¾ Nomex reinforced silicone 1 polyester reinforced silicone Regulator components stainless steel/brass/nitrile Spring stainless steel Media temp range KR valve assembly Body pressure rating lose off pressure ifferential pressure (ΔP) range Leakage 0 F to 212 F [-18 to +100 ] 0 F to 176 F [-18 to +80 ] 600 psi 200 psi 5 to 50 psid ANSI lass IV (0.01% of rated valve capacity at 50 psi differential) Tefzel and Tefl on are registered trademarks of upont 8
9 Factory Set P2... Series Pressure Independent haracterized ontrol s (PIV) hrome Plated Brass Ball and Brass Stem, NPT Female Ends Application The Pressure Independent haracterized ontrol is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV reheat coils. This valve is suitable for use in a hydronic system with constant or variable flow. This valve is designed with MFT functionality which facilitates the use of various control input. Flow Rate Nominal Size Suitable Actuators Technical ata Service chilled or hot water, 60% glycol Flow characteristic equal percentage Size ½, ¾, 1 Type of end fi tting female, NPT Materials Body forged brass, nickel plated Ball chrome plated brass Stem chrome plated brass Seat O-rings Viton Seat fi berglass reinforced Tefl on PTFE haracterizing disc ½ & ¾ Brass 1 TEFZEL Packing 2 EPM O-rings, lubricated iaphragm ½ & ¾ silicone and Nomex 1 polyester reinforced silicone Regulator components stainless steel/brass/nitrile Spring stainless steel Body pressure rating 600 PSI Media temp. range 0 F to 212 F [-18 to +100 ] lose off pressure 200 PSI Leakage ANSI lass IV (0.01% of rated valve capacity at 50 psi differential) Rangeability 100 : 1 ifferential pressure 5 to 50 PSI operating range accuracy ± 5%* Weight of valve body ½ = 2.52 lbs ¾ = 2.52 lbs 1 = 4.98 lbs ½ body has three discs with different flow capbilities (.50 GPM to 1 GPM), (1.5 GPM to 2.5 GPM), (3 GPM to 5.5 GPM) 1 body has two discs with different flow capabilities (11 GPM to 16 GPM), (17 GPM to 19 GPM) Tefzel and Teflon are registered trademarks of upont * See page 3 for more details. Model GPM Liter/sec Inches mm lose-off PSI P2050B005(-P) ½ P2050B010(-P) ½ P2050B015(-P) ½ P2050B020(-P) ½ P2050B025(-P) ½ P2050B030(-P) ½ P2050B035(-P) ½ P2050B040(-P) ½ P2050B045(-P) ½ P2050B050(-P) ½ P2050B055(-P) ½ P2075B060(-P) ¾ P2075B065(-P) ¾ P2075B070(-P) ¾ P2075B075(-P) ¾ P2075B080(-P) ¾ P2075B085(-P) ¾ P2075B090(-P) ¾ P2075B095(-P) ¾ P2075B100(-P) ¾ PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) (-P) optional, ΔP verification across valve using PT ports Spring Return TFR24-MFT US LF24-MFT US LRB(X)24-3 Non-Spring Return LRX24-MFT LRB24-3 Heat Pump Only 9
10 Field Set P2... Series Pressure Independent haracterized ontrol s hrome Plated Brass Ball and Brass Stem, NPT Female Ends is supplied at maximum fl ow in the full open position only. Field adjustment is necessary to achieve lower flow. Application The Pressure Independent haracterized ontrol is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV re-heat coils. This valve is suitable for use in a hydronic system with constant or variable flow. Nominal Size Suitable Actuators Technical ata Service chilled or hot water, 60% glycol Flow characteristic equal percentage Size ½, ¾, 1 Type of end fi tting female, NPT Materials Body forged brass, nickel plated Ball chrome plated brass Stem chrome plated brass Seat O-rings Viton Seat fi berglass reinforced Tefl on PTFE haracterizing disc ½ & ¾ brass 1 TEFZEL Packing 2 EPM O-rings, lubricated iaphragm ½ & ¾ silicone and Nomex 1 polyester reinforced silicone Regulator components stainless steel/brass/nitrile Spring stainless steel Body pressure rating 600 PSI Media temp. range LRB24-SA 0 F to 212 F [-18 to +100 ] KRB F to 176 F [-18 to +80 ] lose off pressure 200 PSI Leakage ANSI lass IV (0.01% of rated valve capacity at 50 psi differential) Rangeability 100 : 1 ifferential pressure 5 to 50 psi operating range accuracy ± 5%* Weight of valve body ½ = 2.52 lbs [1.14 kg] ¾ = 2.52 lbs [1.14 kg] 1 = 4.98 lbs [2.26 kg] Tefzel and Teflon are registered trademarks of upont. *See page 3 for more details. Model GPM Range Inches mm lose-off PSI P2050B ( ) ½ P2050B ( ) ½ P2050B ( ) ½ P2075B (5.7-10) ¾ PIV (11-16) PIV (17-21) PT Ports Model GPM Range Inches Nominal Size mm lose-off PSI P2050B010-P 0...( ) ½ P2050B025-P 0...( ) ½ P2050B055-P 0...( ) ½ P2075B100-P 0...(5.7-10) ¾ PIV P 0...(11-16) PIV P 0...(17-21) (-P) optional, ΔP verification across valve using PT ports. Flow Verification Orifice Model GPM Range Inches Nominal Size mm lose-off PSI P2050B010-F 0...( ) ½ P2050B025-F 0...( ) ½ P2050B055-F 0...( ) ½ P2075B100-F 0...(5.7-10) ¾ PIV F 0...(11-16) PIV F 0...(17-21) (-F) optional, flow verification using ΔP across orifice. Non-Spring Return KRB24-3 LRB24-SA Suitable Actuators Non-Spring Return KRB24-3 LRB24-SA Suitable Actuators Non-Spring Return KRB24-3 LRB24-SA 10
11 Factory Set P2... Series Pressure Independent haracterized ontrol s (PIV) hrome Plated Brass Ball and Brass Stem, NPT Female Ends Application The Pressure Independent haracterized ontrol is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV reheat coils. This valve is suitable for use in a hydronic system with constant or variable flow. This valve is designed with MFT functionality which facilitates the use of various control input. Flow Rate Nominal Size Suitable Actuators Technical ata Service chilled or hot water, 60% glycol Flow characteristic equal percentage Size 1¼, 1½, 2 Type of end fi tting female, NPT Materials Body forged brass, nickel plated Ball chrome plated brass Stem chrome plated brass Seat O-rings Viton Seat fi berglass reinforced Tefl on PTFE haracterizing disc TEFZEL Packing 2 EPM O-rings, lubricated iaphragm polyester reinforced silicone Regulator components stainless steel/brass/nitrile Spring stainless steel Body pressure rating 400 PSI Media temp. range 0 F to 212 F [-18 to 100 ] lose-off pressure 200 PSI Leakage ANSI lass IV (0.01% of rated valve capacity at 50 psi differential) Rangeability 100 : 1 ifferential pressure 5 to 50 PSI operating range accuracy ± 5%* Weight of valve body 1¼ = 8.31 lbs 1½ = 7.70 lbs 2 = 9.38 lbs 2 large = lbs 2 body has two different flow capacities (44 GPM to 80 GPM) (90 GPM & 100 GPM) Tefzel and Tefl on are registered trademarks of upont. *See page 3 for more details. Model GPM Liter/sec Inches mm lose-off PSI PIV (-P) ¼ PIV (-P) ¼ PIV (-P) ¼ PIV (-P) ¼ PIV (-P) ¼ PIV (-P) ¼ PIV (-P) ¼ PIV (-P) ¼ PIV (-P) ¼ PIV (-P) ½ PIV (-P) ½ PIV (-P) ½ PIV (-P) ½ PIV (-P) ½ PIV (-P) ½ PIV (-P) ½ PIV (-P) ½ PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) PIV (-P) (-P) optional, ΔP verification across valve using PT ports Spring Return AFRX24-MFT US Non-Spring Return ARX24-MFT 11
12 Field Set KRB24-3 Actuator, On/Off, Floating Point imensions (Inches ) 1.35 [34.2] [62.8] 6.30 [160] Models KRB24-3 Technical ata Power supply 24 VA ± 20% 50/60 Hz 24 V ± 20% Power consumption 1.0 W (0.2 W resting) Transformer sizing 1.5 VA (lass 2 power source) Electrical connection 3 ft., 18 GA appliance rated cable protected NEMA 2 (IP54) Overload protection electronic throughout rotation ontrol on/off, fl oating point Angle of rotation without end stop; limitless with end stop; 315 fi x max. with two end stops Torque 18 in-lbs [2 Nm] irection of rotation by electrical installation Position indication reflective visual indicator (snap-on), with magnet Manual override disengage with magnet Running time 75 seconds, constant independent of load Humidity 5 to 95% RH non condensing (EN ) Ambient temperature -22 F to +122 F [-30 to +50 ] Storage temperature -40 F to +176 F [-40 to +80 ] Housing NEMA 2, IP54 Noise level <45dB(A) Servicing maintenance free Quality standard ISO 9001 Weight 0.4 lbs [0.18 kg] Rated Impulse Voltage 800V, Type of action 1, ontrol Pollution egree 3. is supplied at maximum flow in the full open position only. Field adjustment is necessary to achieve lower flow. E F Nominal Size imensions (Inches ) ½ " [167] 4.47" [114] 5.09" [129] 2.34" [59] 1.35" [34] 1.25" [32] ¾ " [173] 5.4" [137] 5.09" [129] 2.34" [59] 1.35" [34] 1.25" [32] imensions with PT Port (Inches ) E 2.47 [62.8] F 1.35 [34.2] B A B A 6.30 [160] Nominal Size imensions (Inches ) ½ " [167] 4.47" [114] 6.43" [163] 3.54" [90] 1.35" [34] 2.4" [61] ¾ " [173] 5.4" [137] 6.43" [163] 3.54" [90] 1.35" [34] 2.4" [61]
13 Field Set KRB24-3 Actuator, On/Off, Floating Point imensions with Orifice* (Inches ) Wiring iagrams 2.47 [62.8] 1.35 [34.2] 6.30 [160] Provide overload protection and disconnect as required. 2 AUTION Equipment amage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 V. E F Nominal Size imensions (Inches ) ½ " [193] 7.6" [193] 5.09" [129] 2.34" [59] 1.35" [34] 1.25" [32] ¾ " [217] 8.53" [217] 5.09" [129] 2.34" [59] 1.35" [34] 1.25" [32] A,B WARNING Live Electrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W536_08 Typical Specification Actuators shall have brushless motor technology and be protected from overload at all angles of rotation. Actuators shall have manual override on the cover. Run time shall be constant and independent of torque. Actuators shall have a 5-year warranty, and be manufactured under ISO 9001 International Quality ontrol Standards. Actuators shall be as manufactured by Belimo. On/Off ontrol W537_08 SAFETY NOTES The actuator is not allowed to be used outside the specifi ed fi eld application. Assembly must be carried out by trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. The device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. The cable must not be removed from the device. The device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. Floating Point or On/Off ontrol 13
14 LRB24-SA Actuator, Proportional imensions (inches ) 2.6" [66] 6.5" [165] " [82] 1.69" [42] 2.34" [59.4] Model LRB24-SA Technical ata Power supply 24 VA ± 20% 50/60 Hz 24 V ± 10% Power consumption running 1.5 W holding 0.2 W Transformer sizing 2 VA (class 2 power source) Electrical connection 3 ft., 18 GA, plenum rated cable ½ conduit connector Overload protection electronic throughout 0 to 95 rotation ontrol proportional (2-10 V) Angle of rotation 90, adjustable with mechanical stop Position indication handle Manual override external push button Running time 90 seconds, constant independent of load Humidity 5 to 95% RH, non-condensing (EN ) Ambient temperature -22 F to +122 F [-30 to +50 ] Storage temperature -40 F to +176 F [-40 to +80 ] Housing type NEMA 2/IP54 Housing material UL94-5VA Agency listings culus acc. to UL A/-2-14, AN/SA E , SA 22.2 No , E acc. to 89/336/EE Noise level less than 35 db (A) Quality standard ISO 9001 Rated impulse voltage 800V, ontrol pollution degree 3, Type of action 1 (1.B for -S models) is supplied at maximum flow in the full open position only. Field adjustment is necessary to achieve lower flow. E F B A Nominal Size imensions (Inches ) ½ " [195] 4.47" [114] 7.13" [181] 2.34" [59] 1.48" [38] 1.48" [38] ¾ " [203] 5.4" [137] 7.13" [181] 2.34" [59] 1.48" [38] 1.48" [38] " [226] 6.85" [174] 8.02" [204] 3.23" [82] 1.6" [41] 1.6" [41] imensions with PT Port (Inches ) E 2.6" [66] F 3.22" [82] 1.69" [42] 6.5" [165] A B 2.34" [59.4] Nominal Size imensions (Inches ) ½ " [195] 4.47" [114] 8.47" [215] 3.54" [90] 1.48" [38] 2.4" [61] ¾ " [203] 5.4" [137] 8.47" [215] 3.54" [90] 1.48" [38] 2.4" [61]
15 LRB24-SA Actuator, Proportional imensions with PT Port (Inches ) Wiring iagrams 2.6" [66] 3.22" [82] 1.69" [42] 6.5" [165] 2.34" [59.4] AUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 V. 5 Only connect common to neg. (-) leg of control circuits. 7 A 500 resistor converts the 4 to 20 ma control signal to 2 to 10 V. 18 Actuators with plenum rated cable do not have numbers on wires; use color codes instead. A,B E F Nominal Size imensions (Inches ) " [320] 12.6" [320] 8.02" [204] 2.95" [75] 1.6" [41] 1.6" [41] Meets culus requirements without the need of an electrical ground connection WARNING Live Electrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. imensions with Orifice* (Inches ) 2.6" [66] 6.5" [165] 1311 Line Volts 24 VA Transformer Blk (1) ommon Red (2) + Hot W123 E F 3.22" [82] 1.69" [42] Nominal Size imensions (Inches ) ½ " [193] 7.6" [193] 4.05" [103] 2.34" [59] 1.25" [32] 1.25" [32] ¾ " [217] 8.53" [217] 4.05" [103] 2.34" [59] 1.25" [32] 1.25" [32] " [226] 8.9" [226] 8.02" [204] 3.23" [82] 1.6" [41] 1.6" [41] *Flow verifi cation orifi ce available August A, B 2.34" [59.4] On/Off V/4-20 ma Max Line Volts Function 100% 24 VA Transformer ( ) ontrol Signal (+) V/mA 2 to 10 V ( ) Feedback Signal (+) 5 a 7 a Ω 500 Ω Wht (3) + Input 3 Blk (1) ommon Red (2) + Hot 18 Wht (3) Y Input, 2 to 10V Org (5) U Output, 2 to 10V 15
16 LRB24-3, LRB24-3-S, LRX24-3 Actuators, On/Off, Floating Point imensions (inches ) 2.6" [66] 6.5" [165] " [82] 1.69" [42] FlowSetR 0.78" [20] imensions 2.34" [59.4] Models LRB24-3 LRB24-3-S LRX24-3 w/built-in Aux. Switch Technical ata Power supply 24 VA ± 20% 50/60 Hz 24 V ± 10% Power consumption running 1.5 W holding 0.2 W Transformer sizing 2 VA (class 2 power source) Electrical connection 3 ft., 18 GA, plenum rated cable ½ conduit connector Overload protection electronic throughout 0 to 95 rotation ontrol on/off, fl oating point Input impedance 600 Ω Angle of rotation 90, adjustable with mechanical stop irection of rotation reversible with protected Position indication handle Manual override external push button Running time 95 seconds, constant independent of load Humidity 5 to 95% RH, non-condensing (EN ) Ambient temperature -22 F to +122 F [-30 to +50 ] Storage temperature -40 F to +176 F [-40 to +80 ] Housing type NEMA 2/IP54 Housing material UL94-5VA Agency listings culus acc. to UL A/-2-14, AN/SA E , SA 22.2 No , E acc. to 89/336/EE Noise level less than 35 db (A) Quality standard ISO 9001 LRB24-3-S Auxiliary switch 1 SPT, 3A 250 VA, UL Listed, adjustable 0 to 100 Rated impulse voltage 800V, ontrol pollution degree 3, Type of action 1 (1.B for -S models) E F Nominal Size imensions (Inches ) ½ " [195] 4.47" [114] 7.91" [201] 2.34" [59] 1.48" [38] 1.48" [38] ¾ " [203] 5.4" [137] 7.91" [201] 2.34" [59] 1.48" [38] 1.48" [38] " [226] 6.85" [174] 8.8" [224] 3.23" [82] 1.6" [41] 1.6" [41] imensions with PT Port (Inches ) E 2.6" [66] F 3.22" [82] 1.69" [42] B A 6.5" [165] A B 0.78" [20] FlowSetR imensions " [59.4] Nominal Size imensions (Inches ) ½ " [195] 4.47" [114] 9.25" [235] 3.54" [90] 1.48" [38] 2.4" [61] ¾ " [203] 5.4" [137] 9.25" [235] 3.54" [90] 1.48" [38] 2.4" [61] 16
17 LRB24-3, LRB24-3-S, LRX24-3 Actuators, On/Off, Floating Point imensions with PT Port (Inches ) Wiring iagrams 2.6" [66] 3.22" [82] 1.69" [42] 6.5" [165] 2.34" [59.4] 0.78" [20] FlowSetR imensions AUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Actuators are provided with color coded wires. Wire numbers are provided for reference. 4 Actuators may also be powered by 24 V. A,B E F Nominal Size imensions (Inches ) " [320] 12.6" [320] 8.02" [204] 2.95" [75] 1.6" [41] 1.6" [41] Meets culus or UL and SA requirements without the need of an electrical ground connection. WARNING Live Electrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Line Volts 24 VA Transformer 4 3 Blk (1) ommon Red (2) + a open a closed a Wht (3) The indication of direction is valid for switch position 1. LRB24-3 On/Off ontrol 24 VA Transformer 4 3 W123 Floating Point ontrol Auxiliary Switch Line Volts The indication of direction is valid for switch position 1. Blk (1) ommon Red (2) + Wht (3) LRB24-3 S1 S2 S3 N NO LRB24-3-S 0 to 95 W169 17
18 LRX120-3 Actuators, On/Off, Floating Point imensions (Inches ) 1321 Models LRX120-3 Technical ata ontrol Power supply Power consumption Transformer sizing Electrical connection Overload protection Input impedance Angle of rotation irection of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings on/off, fl oating point 100 to 240 VA, 50/60 Hz (nominal) 85 to 265 VA, 50/60 Hz (tolerance) running 2 W holding 0.5 W 4 VA (class 2 power source) ½ conduit connector 18 GA, plenum rated cable 3 ft. [1m] 10 ft. [3m] 16 ft. [5m] electronic throughout 0 to 95 rotation 600 Ω 90, adjustable with mechanical stop reversible with protected handle external push button 150, 95, 60, 45, 35 seconds, constant independent of load 5 to 95% RH non-condensing (EN ) -22 F to +122 F [-30 to +50 ] -40 F to +176 F [-40 to +80 ] NEMA 2/IP54 UL94-5VA culus acc. to UL A/-2-14, AN/SA E , SA 22.2 No , E acc. to 89/336/EE (and 2006/95/E for line voltage and/or -S versions) <35 db(a) Noise level Quality standard ISO 9001 Rated impulse voltage 4kV, ontrol pollution degree 3, Type of action 1 E F Nominal Size imensions (Inches ) ½ " [195] 4.47" [114] 7.91" [201] 2.34" [59] 1.48" [38] 1.48" [38] ¾ " [203] 5.4" [137] 7.91" [201] 2.34" [59] 1.48" [38] 1.48" [38] " [226] 6.85" [174] 8.8" [224] 3.23" [82] 1.6" [41] 1.6" [41] imensions with PT Port (Inches ) E F Nominal Size imensions (Inches ) ½ " [195] 4.47" [114] 9.25" [235] 3.54" [90] 1.48" [38] 2.4" [61] ¾ " [203] 5.4" [137] 9.25" [235] 3.54" [90] 1.48" [38] 2.4" [61] B A A B
19 LRX120-3 Actuators, On/Off, Floating Point imensions with PT Port (Inches ) Wiring iagrams AUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Meets culus or UL and SA requirements without the need of an electrical ground connection. E WARNING Live Electrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W405 On/Off W406 F A,B Nominal Size imensions (Inches ) " [320] 12.6" [320] 8.02" [204] 2.95" [75] 1.6" [41] 1.6" [41] Floating Point or On/Off ontrol 19
20 LRX24-MFT Actuators, Multi-Function Technology imensions (inches ) 2.6" [66] 7.5" [191] " [82] 1.69" [42] 2.34" [59.4] E F B A Model LRX24-MFT Technical ata Power supply 24 VA ± 20% 50/60 Hz 24 V ± 10% Power consumption running 2 W holding 1.2 W Transformer sizing 5 VA (class 2 power source) Electrical connection 18 GA plenum rated cable 1/2 conduit connector 3 ft. [1m] 10 ft. [3m] 16 ft. [5m] Overload protection electronic throughout 0 to 95 rotation Operating range Y 2 to 10 V, 4 to 20 ma (default) variable (V, PWM, fl oating point, on/off) Input impedance 100 kω (0.1 ma), 500 Ω 1500 Ω (PWM, fl oating point, on/off) Feedback output U 2 to 10 V, 0.5mA max V variable Angle of rotation max. 95, adjust. with mechanical stop electronically variable Torque 45 in-lbs [5 Nm] irection of rotation reversible with protected Position indication handle Manual override external push button Running time 100 seconds variable (35 to 150 seconds) Humidity 5 to 95% RH non condensing (EN ) Ambient temperature -22 F to +122 F [-30 to +50 ] Storage temperature -40 F to +176 F [-40 to +80 ] Housing NEMA 2/IP54 Housing material UL94-5VA Agency listings culus acc. to UL A/-2-14, AN/SA E , SA 22.2 No , E acc. to 89/336/EE Noise level <35dB(A) Quality standard ISO 9001 Weight 1.5 lbs [0.7 kg] Rated impulse voltage 800V, ontrol pollution degree 3, Type of action 1 (1.B for -S models) Nominal Size imensions (Inches ) ½ " [220] 4.47" [114] 7.13" [181] 2.34" [59] 1.48" [38] 1.48" [38] ¾ " [228] 5.4" [137] 7.13" [181] 2.34" [59] 1.48" [38] 1.48" [38] " [251] 6.85" [174] 8.02" [204] 3.23" [82] 1.6" [41] 1.6" [41] imensions with PT Port (Inches ) E 2.6" [66] F 3.22" [82] 1.69" [42] 7.5" [191] A B " [59.4] Nominal Size imensions (Inches ) ½ " [220] 4.47" [114] 8.47" [215] 3.54" [90] 1.48" [38] 2.4" [61] ¾ " [228] 5.4" [137] 8.47" [215] 3.54" [90] 1.48" [38] 2.4" [61] 20
21 LRX24-MFT Actuators, Multi-Function Technology imensions with PT Port (Inches ) 2.6" [66] 3.22" [82] 1.69" [42] 7.5" [191] 2.34" [59.4] VA/ Transformer Line Volts 3 Position ( ) Feedback V (+) a 2 Blk (1) ommon Red (2) Hot Wht (3) Y Input Org (5) U Output W538 MFT On/Off ontrol A,B E F Nominal Size imensions (Inches ) " [320] 12.6" [320] 8.02" [204] 2.95" [75] 1.6" [41] 1.6" [41] Floating Point Line Volts 24 VA Transformer A 3 B to 10 V Feedback Signal 4 2 Blk (1) ommon Red (2) Hot + Wht (3) Y 1 Input 9 Pnk (4) Y 2 Input Org (5) U Output 2 to 10V MFT W538 Wiring iagrams 2 AUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Line Volts 24 VA Transformer 3 ontrol Signal ( ) 4 to 20 ma (+) or 2 to 10 V 2 Ω 500Ω 1/4 watt Blk (1) ommon Red (2) + Hot Wht (3) Y 1 Input, 2 to 10V Org (5) U Output, 2 to 10V MFT W538 3 Actuators may also be powered by 24 V Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. ontrol signal may be pulsed from either the Hot (source) or the ommon (sink) 24 VA line. ontact closures A & B also can be triacs. A& B should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection. The ZG-R Ω resistor converts the 4 to 20 ma control signal to 2 to 10 V, up to 2 actuators may be connected in parallel. WARNING Live Electrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. V/4-20 ma PWM Line Volts 24 VA Transformer (A only) 2 Position ( ) Feedback V (+) 6 Blk (1) ommon Red (2) + Hot Wht (3) Y Input Org (5) U Output MFT W538 21
22 ARX24-MFT Actuators, Multi-Function Technology imensions (inches ) 1323 Models ARX24-MFT Technical ata Power supply 24 VA ± 20% 50/60 Hz 24 V ± 10% Power consumption running 4 W holding 1.25 W Transformer sizing 6 VA (class 2 power source) Electrical connection ½ conduit connector 18 GA plenum rated cable 3 ft. [1m] 10 ft. [3m] 16 ft. [5m] Overload protection electronic throughout 0 to 95 rotation Operating range Y 2 to 10 V, 4 to 20 ma (default) variable (V, PWM, fl oating point, on/off) Input impedance 100 kω (0.1 ma), 500 Ω 1500 Ω (PWM, fl oating point, on/off) Feedback output U 2 to 10 V, 0.5 ma max V variable Angle of rotation 95 electronically variable irection of rotation reversible with protected Position indication handle Manual override external push button Running time 100 seconds Humidity 5 to 95% RH non-condensing (EN ) Ambient temperature -22 F to +122 F [-30 to +50 ] Storage temperature -40 F to +176 F [-40 to +80 ] Housing NEMA 2/IP54 Housing material UL94-5VA Agency listings culus acc. to UL A/-2-14, AN/SA E , SA 22.2 No , E acc. to 89/336/EE Noise level <45 db(a) Quality standard ISO 9001 Rated impulse voltage 4kV, ontrol pollution degree 3, Type of action 1 Nominal Size imensions (Inches ) 1¼ " [230] 8.19" [208] 8.73" [222] 3.5" [89] 1.85" [47] 1.85" [47] 1½ " [231] 8.03" [204] 8.73" [222] 3.5" [89] 1.85" [47] 1.85" [47] " [241] 8.50" [216] 8.97" [228] 3.5" [89] 1.85" [47] 1.85" [47] 2 NPT with fl ows to 40 GPM. imensions (inches ) E 3.46" [88] 2.5" [64] F 2.49" [63.4] 8.0" [203] 3.3" 1.35" [84] [35] BELIMO 50 Nominal Size imensions (Inches ) " [480] [396] 12.83" [326] 5.83" [148] 2.6" [66] 2.6" [66] 2 NPT with larger flows from 44 GPM to 100 GPM B A
23 ARX24-MFT Actuators, Multi-Function Technology imensions with PT Port (Inches ) 2.6" [66] 3.22" [82] 1.69" [42] 6.5" [165] 2.34" [59.4] ontrol signal may be pulsed from either the Hot (source) or the ommon (sink) 24 VA line. ontact closures A & B also can be triacs. A& B should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection. E F Nominal Size imensions (Inches ) 1¼ " [403] 15.9" [403] 8.73" [222] 3.5" [89] 1.85" [47] 1.85" [47] 1½ " [392] 15.43" [392] 8.73" [222] 3.5" [89] 1.85" [47] 1.85" [47] " [410] 16.13" [410] 8.97" [228] 3.5" [89] 1.85" [47] 1.85" [47] A,B The ZG-R Ω resistor converts the 4 to 20 ma control signal to 2 to 10 V, up to 2 actuators may be connected in parallel. WARNING Live Electrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W538 imensions with PT Port (Inches ) 3.46" [88] 2.5" 8.0" [203] [64] 1313 On/Off ontrol W " [63.4] 1.35" [35] 3.3" [84] A, B E F Nominal Size imensions (Inches ) " [596] 23.25" [591] 12.83" [326] 5.83" [148] 2.6" [66] 2.6" [66] Wiring iagrams Floating Point V/4-20 ma W538 W538 2 AUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 V. 4 Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. PWM 23
24 TFRX24-MFT US Actuators, Multi-Function Technology imensions (Inches ) 3.0" [76.2] 6.28" [159.55] " [74.5] 2.40" [61] E F B A Models TFRX24-MFT US Technical ata ontrol MFT Power supply 24 VA ± 20% 50/60 Hz 24 V ± 10% Power consumption running 2.5 W holding 1.0 W Transformer sizing 4 VA (class 2 power source) Electrical connection 3 ft., 18 GA plenum rated cable ½ conduit connector Overload protection electronic throughout 0 to 95 rotation Operating range Y* 2 to 10 V 4 to 20 ma (with 500 Ω, ¼ W resistor) ZG-R01 Input impedance 100 kω for 2 to 10 V (0.1 ma) 500 Ω for 4 to 20 ma 1500 Ω for PWM, fl oating point and on/off control Feedback output U* 2 to 10 V, 0.5 ma max irection of rotation spring reversible with W/W mounting motor reversible with built-in Mechanical angle of rotation* 95 Running time motor* 100 seconds spring <25 -4 F to +122 F [-20 to +50 ] < F [-30 ] Angle of rotation adaptation* off (default) Override control* min. (min position) = 0% - ZS (mid. position) = 50% - max. (max. position) = 100% Position indication visual indicator, 0 to 95 Humidity 5 to 95% RH, non-condensing Ambient temperature -22 F to +122 F (-30 to +50 ) Storage temperature -40 F to +176 F (-40 to +80 ) Housing NEMA 2/IP42 Housing material UL 94-5VA Noise level (max) running <35 db (A) spring return <65 db (A) Agency listings culus acc. to UL A/-2-14, AN/SA E , SA 22.2 No.24-93, E acc to 89/336/EE Quality standard ISO 9001 * Variable when configured with MFT options Rated impulse voltage 0.8 kv, ontrol pollution degree 3, Type of action 1.AA. Nominal Size imensions (Inches ) ½ " [180] 4.47" [114] 6.98" [177] 2.34" [60] 1.5" [38] 1.5" [38] imensions with PT Port (Inches ) E 3.0" [76.2] F 2.93" [74.5] A B 6.28" [159.55] " [61] Nominal Size imensions (Inches ) ½ " [180] 4.47" [114] 8.01" [203] 3.54" [90] 1.5" [38] 2.4" [61] 24
25 TFRX24-MFT US Actuators, Multi-Function Technology Wiring iagrams W024 1 Provide overload protection and disconnect as required. 2 AUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 V. 4 ZG-R01 may be used. WARNING Live Electrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W025 4 to 20 ma ontrol Signal 2 to 10 V ontrol Signal 25
26 LF24-MFT Actuators, Multi-Function Technology imensions (Inches ) 3.78" [96] 7.64" [194] " [114] 2.28" [58] Models LF24-MFT LF24-MFT-S w/built-in aux. switch Technical ata ontrol MFT ontrol signal 2 to 10 V Power consumption running 2.5 W holding 1 W Transformer sizing 5 VA (class 2 power source) Electrical connection 3 ft., 18 GA appliance cables (-S model has 2 cables) ½ conduit connector Overload protection electronic throughout 0 to 95 rotation Input impedance 100 kω for 2 to 10 V (0.1 ma) 500 Ω for 4 to 20mA 750 Ω for PWM 500 Ω for on/off and fl oating point Feedback 2 to 10 V, 0.5 ma max Angle of rotation 95 irection of rotation spring reversible with W/W mounting motor reversible with built-in Position indication visual indicator Running time <40 to 75 seconds (on-off) 100 seconds spring <25 F to +122 F [-20 to +50 ] <60 F [-30 ] Ambient temperature -22 F to +122 F [-30 to +50 ] Housing NEMA 2 Agency listings UL 873, SA 22.2 No. 24 certifi ed, E Noise level max. 62 db(a) Quality standard ISO 9001 LF24-MFT-S US Auxiliary switch 1 x SPT, 6A 250 VA, UL Listed, adjustable 0 to 95 (double insulated) E F Nominal Size imensions (Inches ) ½ " [206] 4.47" [114] 8.54" [217] 2.34" [59] 1.89" [48] 1.89" [48] ¾ " [211] 5.4" [137] 8.54" [217] 2.34" [59] 1.89" [48] 1.89" [48] " [231] 6.85"[174] 9.29" [236] 3.23" [82] 1.89" [48] 1.89" [48] imensions with PT Port (Inches ) E 3.78" [96] F 4.49" [114] B A A B 7.64" [194] " [58] Nominal Size imensions (Inches ) ½ " [206] 4.47" [114] 9.57" [243] 3.54" [90] 1.89" [48] 2.4" [61] ¾ " [211] 5.4" [137] 9.57" [243] 3.54" [90] 1.89" [48] 2.4" [61] 26
27 LF24-MFT Actuators, Multi-Function Technology imensions with PT Port (Inches ) 24 VA/ Transformer W " [96] 7.64" [194] 1316 Line Volts (1) ommon (2) Hot 4.49" [114] 2.28" [58] Position ( ) Feedback V (+) a (3) Y Input (5) U Output W W MFT On/Off ontrol 24 VA Transformer (A only) W041 Line Volts 7 Position Feedback V PWM, Triac Source and Sink ( ) (+) 6 (1) ommon (2) + Hot (3) Y Input (5) U Output W W MFT W302 A,B E F Nominal Size imensions (Inches ) " [320] 12.6" [320] 9.25" [235] 2.95" [75] 1.89" [48] 1.89" [48] Wiring iagrams 2 AUTION Equipment damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 V. 4 IN4004 or IN4007 diode (IN4007 supplied, Belimo part number 40155). 5 Triac A and B can also be contact closures. ontrol signal may be pulsed from either the Hot (Source) or 6 ommon (Sink) 24 VA line. Position feedback cannot be used with Triac sink controller. 7 The actuators internal common reference is not compatible. The ZG-R Ω resistor converts the 4 to 20 ma control signal to 2 to 10 V, up to 2 actuators may be connected in parallel. WARNING Live Electrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Floating Point ontrol Proportional 2 to 10 or 4 to 20 ma ontrol Signal 27
28 AFRX24-MFT, AFRX24-MFT-S Actuators, Multi-Function Technology imensions (Inches ) 4.04 [102.7] 9.77 [248.2] 3.93 [99.9] 2.50 [63.5] 1327 Models AFRX24-MFT AFRX24-MFT-S w/built-in aux. switches Technical ata ontrol MFT ontrol signal 24 VA, +/- 20%, 50/60 Hz 24 V, +20% / -10% Power supply 7.5 W Power consumption running 3 W holding 10 VA (class 2 power source) Transformer sizing 10 VA (class 2 power source) Electrical connection 3 ft. [1m], 10 ft. [3m] or 16 ft. [5m] 18 GA appliance or plenum cables, with or without ½ conduit connector -S models: two 3 ft. [1m], 10 ft. [3m] or 16 ft. [5m] appliance cables with or without ½ conduit connectors Overload protection electronic throughout 0 to 95 rotation Input impedance 100 kω for 2 to 10 V (0.1 ma) 500 Ω for 4 to 20 ma 1500 Ω for PWM, floating point and on/off control Feedback output 2 to 10 V, 0.5 ma max Angle of rotation 95 irection of rotation spring reversible with W/W mounting motor reversible with built-in Position indication visual indicator Manual override hex crank Running time spring <20 -4 F to +122 F [-20 to +50 ]; < F [-30 ] motor 150 seconds (default), variable (70 to 220 seconds) Ambient temperature -22 F to +122 F (-30 to +50 ) Housing NEMA 2, IP54, Enclosure Type 2 Agency listings culus acc. to UL A/-2-14, AN/SA E :02, E acc. to 2004/108/E & 2006/95/E Noise level 40dB(A) 150 seconds, run time dependent 62dB(A) spring return AFRX24-MFT-S US Auxiliary switches 2 x SPT, 7A 250 VA, UL listed, one switch is fi xed at +5, one is adjustable 25 to 85 (double insulated) Nominal Size imensions (Inches ) 1¼ " [277] 8.19" [208] 9.6" [244] 3.66" [93] 2.02" [51] 2.02" [51] 1½ " [285] 8.03" [204] 9.6" [244] 3.66" [93] 2.02" [51] 2.02" [51] " [284] 8.5" [216] 9.84" [250] 3.66" [93] 2.02" [51] 2.02" [51] 2 NPT with fl ows to 40 GPM imensions (Inches ) 4.04 [102.7] 2.5 [63.5] 9.77 [248.2] Nominal Size imensions (Inches ) " [559] 15.6" [396] 12.87" [327] 5.87" [149] 2.64" [67] 2.64" [67] 2 NPT with larger flows from 44 GPM to 100 GPM 3.93 [99.9]
29 AFRX24-MFT, AFRX24-MFT-S Actuators, Multi-Function Technology imensions with PT Port (Inches ) 4.04 [102.7] 9.77 [248.2] 1317 Line Volts 24 VA/ Transformer (1) ommon (2) Hot W [99.9] 2.50 [63.5] Position ( ) Feedback V (+) a (3) Y Input (5) U Output W W MFT On/Off ontrol 24 VA Transformer (A only) W041 Wiring iagrams 2 E F Nominal Size imensions (Inches ) 1¼ " [403] 15.9" [403] 9.44" [240] 3.5" [89] 2.05" [52] 2.05" [52] 1½ " [392] 15.43" [392] 9.44" [240] 3.5" [89] 2.05" [52] 2.05" [52] " [410] 16.13" [410] 9.68" [246] 3.5" [89] 2.05" [52] 2.05" [52] AUTION Equipment damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 V. IN4004 or IN4007 diode (IN4007 supplied, Belimo part number ). 5 Triac A and B can also be contact closures. ontrol signal may be pulsed from either the Hot (Source) or 6 ommon (Sink) 24 VA line. Position feedback cannot be used with Triac sink controller. 7 The actuators internal common reference is not compatible. ontact closures A & B also can be triacs. 8 A& B should both be closed for triac source and open for triac sink. Meets culus or UL and SA requirements without the need of an electrical ground connection. WARNING Live Electrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. A B Line Volts 7 Position Feedback V PWM, Triac Source and Sink Line Volts 2 to 10 V Feedback Signal ( ) (+) 24 VA Transformer 3 Floating Point ontrol Line Volts 6 A B 3 ontrol Signal ( ) 4 to 20 ma (+) or 2 to 10 V VA Transformer Ω 500Ω 1/4 watt Proportional 2 to 10 or 4 to 20 ma ontrol Signal (1) ommon (2) + Hot (3) Y Input (5) U Output W W MFT Blk (1) ommon Red (2) Hot + Wht (3) Y 1 Input 9 Pnk (4) Y 2 Input Org (5) U Output 2 to 10V MFT Blk (1) ommon Red (2) + Hot Wht (3) Y 1 Input, 2 to 10V Org (5) U Output, 2 to 10V MFT W538 W538 W195-AUXMFT Auxiliary Switches 29
30 Pressure Independent haracterized ontrol Heat Pump Applications Optimize Your Heat Pump Application by Using a Pressure Independent haracterized ontrol What are the benefi ts? A PIV dynamically balances a system by responding to changes in differential pressure. The PIV regulator modulates in response to differential pressures in the system to maintain a constant differential pressure across the ball of the valve. The PIV will maintain a constant fl ow at part load and during morning start-up when all loops become critical. With the PIV, each terminal gets the required fl ow, no overfl ow or underfl ow at this critical time. The PIV allows a mechanic to easily commission additional circuits after the initial system is up and running, again thanks to dynamic balancing capability. The PIV is available in fl ow rates from.5 to 100 GPM. hoosing the right PIV is as easy as determining the appropriate fl ow for your heat pump and then choosing the valve that satisfi es the fl ow requirement. How does it work? The PIV is ideally suited to save pumping cost associated with water source heat pumps. The PIV with On/Off control actuator is used to isolated the zone coil from the main hydronic circuit when the space is not calling for heating or cooling. Hydronic friction is reduced and when the system pump is controlled with a VF, the fl ow is matched to the load of the building. This combination of PIV and VF saves pumping energy 90% of the time when the building load is less than full. The PIV is available with integral -S travel switch models. The switch is wired in series with the compressor enable circuitry to assure water is fl owing through the coil before the compressor starts. WATER SOURE HEAT PUMP IN HEATING MOE WATER SOURE HEAT PUMP IN OOLING MOE 30
31 LRB24-3, LRB24-3-S Actuators, On/Off Application The Pressure Independent haracterized ontrol along with the LRB24-3 is paired together specifi cally for use in Heat Pump applications to precisely control the fl ow of condenser water. This assembly is suitable for use in a hydronic system with constant or variable fl ow. imensions (inches ) 2.6" [66] 6.5" [165] " [82] 1.69" [42] FlowSetR 0.78" [20] imensions 2.34" [59.4] Models LRB24-3 LRB24-3-S Technical ata Power supply 24 VA ± 20% 50/60 Hz 24 V ± 10% Power consumption running 1.5 W holding 0.2 W Transformer sizing 2.5 VA (class 2 power source) Electrical connection 18 GA plenum rated cable 1/2 conduit connector 3 ft. [1m] 10 ft. [3m] 16 ft. [5m] Overload protection electronic throughout rotation ontrol on/off Input impedance 600 Ω Angle of rotation 95 irection of rotation reversible with protected Position indication handle Manual override external push button and handle Running time 40 second constant independent of load Ambient temperature -22 F to +122 F [-30 to +50 ] Housing NEMA 2 / IP54 Housing material UL94-5VA Agency listings culus acc. to UL A/-2-14, AN/SA E , SA 22.2 No , E acc. to 89/336/EE and (-S Models) 2006/95/E Noise level max. 35 db(a) LRB24-3-S Auxiliary switches 1 SPT, 3A (0.5A 250 V Rated Impulse Voltage 800V, Type of action 1 (1.B for -S version), ontrol Pollution egree 3. E F Nominal Size imensions (Inches ) ½ " [195] 4.47" [114] 7.91" [201] 2.34" [59] 1.48" [38] 1.48" [38] ¾ " [203] 5.4" [137] 7.91" [201] 2.34" [59] 1.48" [38] 1.48" [38] " [226] 6.85" [174] 8.8" [224] 3.23" [82] 1.6" [41] 1.6" [41] B A 31
32 LRB24-3, LRB24-3-S Actuators, On/Off Wiring iagrams 1 Provide overload protection and disconnect as required. 3 Actuators may also be powered by 24 V. Meets culus or UL and SA requirements without the need of an electrical ground connection. WARNING Live Electrical omponents! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury VA Transformer 3 W569_B Line Volts Blk (1) ommon Red (2) + a open a closed a Wht (3) + The indication of direction is valid for switch position LRB24-3 On/Off ontrol Auxiliary Switch S1 S2 S3 N NO 0 to 95 LRB24-3-S W169_LRB 32
33 Instructions for FlowSetR Field Adjustment of Flow and Sizing and Selection Instructions for Non-Spring Actuator Utilizing the FlowSetR NON-SPRING RETURN ATUATOR: LRB24-3 EFAULT SET-UP: FlowSetR The factory setting corresponds to the ordered flow rate (selected from Belimo s standard product range). The valves factory setting is in open position (valve always closes in W direction). To set or adjust desired maximum flow (actuator, FlowSetR and valve are connected): 1. Fully close the valve via actuator control signal or via manual override (press button and turn handle in clockwise direction). NOTE: The FlowSetR fixed clockwise end stop purposely prevents the actuator from returning to its full zero-degree position, eliminating excess rotation. 2. Use the integrated hex tool in the actuator lever to turn adjustment screw in plus (+) or minus (-) direction in order to move scale indicator to desired flow rate. A standard hex tool (i.e. Allen wrench) size 5/32 or 4mm can also be used to turn adjustment screw. PIV flow can be field adjusted by using a hex tool. Therefore, the maximum flow can be increased or decreased within the valves adjustable flow range. Integrated Hex Tool Sizing and Selection PRESSURE INEPENENT, ON/OFF, PROPORTIONAL, FLOATING ATUATOR REQUIRE INFORMATION FOR SIZING: flow in GPM FOR SELETION: 2-way valves only pipe size media temperature spring return or non-spring return required close-off pressure (OP) voltage requirement ambient temperature required accessories EQUATIONS USE No equations are required. hoose the PIV that has the closest GPM to the requirement and round up to next available flow. PROEURE 1) Obtain required GPM 2) hoose valve model number that has closest GPM rating (round up) 3) Verify that valve size is not larger than pipe size and in general, do not select a valve less than ½ of the line size 4) Select actuator based upon selection parameters above 5) Based upon actuator/valve selection, verify close-off pressure (OP) meets project requirements FlowSetR Adjustable with hex tool size 5/32 [4mm] Sample scale PIV On Floating Point actuators, the running time is constant but dependent on the overall angle of rotation. Avoid disconnecting FlowSetR from actuator or valve! If necessary, refer to instruction sheet on how to install FlowSetR to valve, and actuator to FlowSetR. EXAMPLE OF V ALULATION 87 GPM is needed choose 90 GPM valve PIV
34 PIV Running Times Note: All MFT actuators have constant running time of 100 seconds. Whether they are set for on/off, floating or proportional control, the running time remains constant. Floating Point ontrol with LR...-3, these actuators have a constant running time. The running time is dependent on the model number or FlowSetR position as indicated in the table below. Some controllers need an adjustment of the running time, otherwise they lose the position information. In any case, we recommend a position reset once a day. Running Time (seconds) Flow Rate (GPM) LRB24-3/LRX120-3 P2050B P2050B P2050B P2050B P2050B P2050B P2050B P2050B P2050B P2050B P2050B P2075B P2075B P2075B P2075B P2075B P2075B P2075B P2075B P2075B PIV PIV PIV PIV PIV PIV PIV PIV PIV
35 Belimo PIV Flow Verification & ommissioning This document details the flow verification and commissioning procedures for PIV (pressure independent characterized control valves). The flow verification techniques contained within this document are optional and at the discretion of the Mechanical Engineer/esigner. These procedures are not mandatory to ensure proper operation of PIV valves. Pressure independent control valves are very different from pressure dependent control valves. Pressure variations in the system will not affect flow through the valve. The ability to adjust and/or control the flow rate which passes through the PI valve is not possible through another mechanical device. Additional mechanical devices should not be used. This makes the TAB/ ommissioning process much different than with standard control valves. Pressure independent valves offer numerous maximum design flow values in each valve body size. It is important to note that most pressure independent valves will not travel a full 90 degrees of rotation when commanded to full design flow position. esign flow in a PIV is adjusted through the maximum angle of ball travel. Therefore, if the valve s maximum flow setting is not at the end of the range, the valve will travel to a point less than 90 degrees. This is normal operation for pressure independent control valves. Note to Mechanical esigner/owner: It is essential that the mechanical contractor install three (3) independent pressure/ temperature ports if the PIV is not supplied with PT ports or a flow orifice device. Please refer to Figure A contained in this document for PT port locations. PT ports allow for true independent verification of proper PIV operationing parameters. Additionally, the PT ports allow for future comprehensive troubleshooting and diagnosis once the system has been in operation for an extended time period. For proper and accurate flow verification of the PIV, it is essential that the mechanical contractor install one additional separate independent pressure/temperature ports (PT) if the PIV valve body is supplied with integrated ports. I. PT port #1 and PT port #2 are used for measuring pressure differential across the coil (used to measure water pressure drop to equate to flow or to measure water temperature delta T through the coil). Figure A H/ OIL AIR VENT FLOW BELIMO PIV (TYP.) PT PORT II. PT port #2 and PT port #3a are used to measure pressure drop across the PIV (must be between 5-50 psi pressure across valve body). Pressure Independent valve body must have required differential pressure within this range WITH VALVE ASSEMBLY OMMANE TO ESIGN FLOW. shall be commanded to design flow position via EMS signal. o not manually open the valve with override handle. This pressure difference across the PIV is necessary to ensure the valve is working pressure independently. Pre Flow Verifi cation System hecklist In order to ensure a properly functioning hydronic system utilizing Pressure Independent haracterizing ontrol s, the mechanical contractor and/or T&B professional must verify that the following items have been confirmed before beginning flow verification. Each flow verification / commissioning procedure presented in this document begins with a reference to the checklist contained below. This serves as a constant reminder to the flow verification professional that these parameters must be met so that proper flow results can be measured / obtained. *Items to check before beginning flow verification procedure: Verify that System is purged of air and filled to proper pressure. Verify that each PIV valve has at least 5 psi but less than 50 psi dp across the valve (fig. A) by following one of the following two measurement options: Reading taken across PT ports 2 & 3a Reading taken across PT port 2 Reading taken across PT ports incorporated on valve body Verify Proper pump operation per manufacturers specifications. Verify proper supply water temperature is available and is at design temperature. Proper Air filter maintenance has been completed. Fan belts are in proper working order. Heat transfer devices (coils) are clean. Strainers are clean. All manual shutoff valves are open. All bypass valves are closed. No automatic or manual balancing valves exist (or if they do, they must be set fully open and locked so as not to interfere with the pressure independency of the PIV). 2 3a PT PORT FLOW SHUT OFF VALVE UNION ONNETION (TYP.) FLOW RAIN PT PORT 1 FLOW STRAINER (Optional) FLOW SHUT OFF VALVE 35
36 Belimo PIV Flow Verification & ommissioning Below are the accepted procedures for verifying/commissioning pressure independent control valves. Procedure #1 (System Verifi cation) Total System Flow Method Verification for PIV ooling s/heating s 1. Verify that System is in proper working order. *See Items to check before beginning flow verification procedure contained at the beginning of this document. 2. ommand open all PIVs in a given system via the building automation system if the total connected load matches the pump capacity and system diversity = 100%. Systems with less than 100% diversity need to have a % of valves closed to match pump capacity. 3. Ensure that pumps are commanded to 100% speed (or VF control loop has high enough dp setpoint to satisfy connected load). 4. Verify total system flow is at system design flow rate via accurate method: alibrated ircuit Setter on main lines Orifice Venturi Ultrasonic Flowmeter 5. ecrease the pump speed (or decrease dp setpoint if under control) until a measureable flow decrease occurs. 6. Increase pump speed (or increase dp setpoint if under control) slowly until design flow is reestablished. Make note of this final measured dp. This will be the correct system dp operating setpoint. NOTE: If total flow does not match design flow then troubleshooting must be done to determine cause. This may involve verifying flows at the terminal level. Procedure #2 (Terminal Level Verifi cation) Air eltat Method Verification for PIV ooling s/heating s 1. Verify that System is in proper working order. *See Items to check before beginning flow verification procedure contained at the beginning of this document. 2. Ensure that water is at design temperature. 3. Ensure that terminal airflow is at design airflow rate (cfm). 4. ommand open pressure independent characterized control valve to maximum design flow position 5. Reference approved engineering document containing design air delta T for heating/cooling coil associated with corresponding pressure independent characterized control valve. 6. Measure coil inlet air temperature and coil discharge air temperature. 7. ifference between coil inlet air reading and coil discharge air reading should equal or exceed design air delta T. Procedure #3 (Terminal Level Verifi cation) Water eltat Method Verification for PIV ooling s/heating s 1. Verify that System is in proper working order. *See Items to check before beginning flow verification procedure contained at the beginning of this document. 2. Ensure that water is at design temperature. 3. Ensure that terminal airflow is at design flow rate (cfm). 4. ommand open pressure independent characterized control valve to maximum design flow position. 5. Reference approved engineering document containing design water deltat for heating/cooling coil associated with corresponding pressure independent characterized control valve. 6. Measure water temperature differential of coil by using PT ports #1 and #2 as referenced in Figure A. PIV models with factory provided PT ports measure the water temperature differential of the coil. 7. Measured temperature differential should be equal to designed water temperature differential. Procedure #4 (Terminal Level Verifi cation) oil dp (eltap) Method Verification for PIV ooling s and PIV Heating s 1. Verify that System is in proper working order. *See Items to check before beginning flow verification procedure contained at the beginning of this document. 2. ommand open pressure independent characterized control valve to maximum design flow position. 3. Reference approved engineering document containing design coil water pressure drop (usually expressed in ft. of H2O) for design flow. This value will be for the heating/cooling coil associated with corresponding pressure independent characterized control valve. 4. Measure coil dp by using PT ports #1 & #2 as referenced in Fig. A. Adjust the angle of the actuator so the differential pressre across the orifice matches the flow required on the table located on page Formula to calculate flow is: Actual GPM = (Measured oil dp/esign oil dp) x esign GPM Note: oil dp and esign dp expressed in feet of H2O. Procedure #5 (Terminal Level Verifi cation) oil Flow for PIV-F Models with Factory Provided Flow Orifi ce 1. Verify that System is in proper working order. *See Items to check before beginning flow verification procedure contained at the beginning of this document. 2. ommand open pressure independent characterized control valve to maximum design flow position. 3. onnect differential pressure gauge to the flow orifice device s high and low pressure PT ports. Reference the gauge reading in the field to the provided published chart to determine the flow rate. 4. All PIV assemblies with flow orifice are motorized with proportional control LRB24-SA or floating point control KRB24-3 actuators. They are shipped from the Belimo factory with default flow setting equal to the maximum Gallons Per Minute (GPM) rating of the valve body. When the coil design GPM is less than the PIV factory default, the user must manually set the actuator travel limit to match the flow rate of the coil. The travel limit of the LRB24-SA is set with a simple electronic push button and the KRB24-3 is set mechanically with a fine tooth gear travel limit mechanism. The new field set PIV maximum flow rate is validated with the flow orifice methodology. 36
37 Belimo PIV Flow Verification & ommissioning Field adjustment of maximum flow and /or flow accuracy. (This function is not a requirement. This procedure is purely optional and is not a mandatory procedure for proper operation of PIV valves.) Flow Accuracy of the PIV valve body is +/-5%. However, actuator hysteresis and installation can have an effect on measured accuracy of the PIV assembly (actuator/valve) in the field. The accuracy of the PIV assembly can be improved in the application. The maximum flow setting and/or flow accuracy can be adjusted in the field using the Belimo P-Tool or ZTH-GEN US (shown on next page). Please contact your local Belimo representative to obtain/purchase this tool or arrange to have a Belimo representative visit the project site to make adjustments. For additional information pertaining to the flow verification and commissioning industry, please visit the website of these organizations that promote the certification and continuing education of industry professionals in the Test and Balance discipline. NEBB - National Environmental Balancing Bureau, TABB - Testing Adjusting Balancing Bureau, 37
38 Flow Setting and Verification for Field Set Actuators KRB24-3, LRB24-SA KRB24-3 Field Setting oil Maximum Flow Procedure The KRB24-3 actuator factory defaults flow setting is equal to the maximum GPM of the valve body it motorizes. If coil design maximum flow is less than the factory default, follow field set procedures below. To field set or adjust the desired maximum flow: Step 1: With Actuator powered by 24VA place factory provided magnet on actuator magnetic gear release area to release internal lock mechanism, allowing the indicator wheel to rotate freely. A click will be heard when it is released. Step 4b: For F models with flow orifice manually rotate the actuator until the measured flow matches the coil differential pressure gauge reading (inches w.c.) and flow reference from provided chart below. Manually position the actuators locking tab to make contact with the right side of the travel limit. Step 5: Reattach the locking tab to the actuator by first engaging at the top with a slight approach angle, and then push down to engage the bottom. A click will be heard when the locking tab is fully seated. Step 2: Access the locking tab by rotating the actuator and associated flow indicator away from the locking tab. Step 6: Remove the magnet from the actuator and retain for future use. Replacement magnets are available with part number LRB24-SA Field Setting oil Maximum Flow Procedure The LRB24-SA actuator factory defaults flow setting is equal to the maximum GPM of the valve body it motorizes. If coil design maximum flow is less than the factory default, follow field set procedures below. To set or adjust the desired maximum flow: Step 3: Using a small flat head screwdriver remove the locking tab by prying out from the bottom. Replace after new position is set according to step 4. Step 4a: Select the valve body and desired flow on the flow table attached to the power cable of the actuator; rotate the flow indicator on the top of the actuator to the desired position on the equal percentage scale. Manually position the actuator travel limit (right side edge with scale facing your view) to equal coil maximum flow. Step 1: With the actuator powered by 24VA depress the black gear release mechanism on the actuator and press down until the locking tab engages to the side of the actuator. If done correctly a click will be heard and gear release will stay depressed. 38
39 Flow Setting and Verification for Field Set Actuators KRB24-3, LRB24-SA Step 2: Select the valve body and desired flow on the flow table attached to the power cable of the actuator, rotate the actuator to the desired position to the maximum coil flow. Field Set Flow Verification Procedure with LRB24-SA and KRB24-3 actuators tools and chart Belimo provided flow orifice has two pressure ports for field elta P measurement with a manometer gauge. onnect monometer high pressure line to flow orifice red PT port; connect low pressure line to green PT port. Follow gauge instructions to verify connections. Take ΔP reading in inches of water (w.c.) and transpose to the PIV line of the Flow hart. From that point follow the corresponding chart line to the flow scale and determine the actual flow. Step 3a: With the desired flow achieved press the translucent button for 3 seconds with tool (e.g. pen tip) to load the position setting in the actuator. The translucent button will glow yellow when the position setting is loaded in the actuator. (Note: uring normal operation the translucent button will only be illuminated when the actuator handle is throttled to the field set maximum flow setting.) Step 3b: For F models with flow orifice manually rotate the actuator until the measured flow matches the coil differential pressure gauge reading (inches w.c.) and flow reference from provided chart. With the desired flow achieved press the translucent button for 3 seconds with tool (e.g. pen tip) to load the position setting in the actuator. The translucent button will glow yellow when the position setting is loaded in the actuator. (Note: uring normal operation the translucent button will only be illuminated when the actuator handle is throttled to the field set maximum flow setting.) Step 4: epress the black gear release mechanism on the side of the actuator to release locking tab. 39
40 P2050B010-F Flow hart Meter Readings, 70 F / 21 P2050B010-F P2050B025-F P2050B055-F P2075B100-F 1 2 P2050B010-F P2050B025-F P2050B055-F P2075B100-F P2050B025-F P2050B055-F P2075B100-F PIV F PIV F P2050B025-F P2050B055-F P2075B100-F PIV F PIV F Temperature orrection Factor: 155 F / 68 = 1.01 x GPM 205 F / 96 = 1.02 x GPM How to etermine Flow: 1. Enter the chart with the P (differential pressure) reading. 2. Go horizontally across to the size of the valve. 3. Go vertically up or down to read the GPM (flow). PIV F PIV F 2 40
41 Operating Instructions ZTH-GEN US The ZTH-GEN US is a tool created to easily adapt the fl ow settings for the PIV in the fi eld. It directly connects to the Belimo actuator. IMPORTANT: There are two ways to connect the tool to the actuators Y 5 U WT BL TQ ZTH-GEN US (ES) Technical Information Supply ommunication Used with actuator types 24 VA/ PP LRX24-MFT TFRX24-MFT LF24-MFT US ARX24-MFT AFRX24-MFT GMX24-MFT LR, AR, GM Series Use the interface on the top of the actuator. (Leave all of the wires of the actuator installed.) TFRX, LF, AFRX Series onnect to the installed wires of the actuator. RE-PROGRAMMING PROESS: Step 1 onnect cable to actuator port, twist to lock in place (or wire as above). Will display actuator for 5 seconds note this and compare to actuator being connected. ZTH-GEN LRX24-MFT Step 2 Start PIV PROESS press OK will be displayed. Press OK. ZTH-GEN START PIV PROESS press ok (ES) (ES) 41
42 Operating Instructions ZTH-GEN US Step 3 N (or NO) run to MAX? Press OK will be displayed. Press OK. NOTE: if you need to change the NO/N action for the actuator, then you must use the P-Tool. hanging the switch will not accomplish this. o not change the Y1/Y2 switch. Step 4 Actuator will drive to current setting (MAX for N, Min for NO). When it stops, adjust using + and buttons. As it is running, it will show actual value as the actuator moves. ZTH-GEN N - > run to MAX? press ok ZTH-GEN actual value 3% drive to MAX (ES) (ES) Step 5 HOL OWN the or + button down to adjust setting. If you disengage the button, then the word stop appears and will change to hold. When setting is changed as needed, press OK. To re-test flow, drive actuator to 80% of current setting and then re-drive to setting. (Ex: setting 70%, drive to 56% or lower and then ZTH-GEN drive back to 70%.) actual value 63% hold adj -> +/- ZTH-GEN Step 6 isplay will state SAVE to MAX (if N) or SAVE to MIN (if NO). Press OK. ZTH-GEN Save to MAX? ok actual value 6 hold adj -> +/- (ES) Step 7 isconnect tool by twisting and re-cover connection port (or un-wire actuator). You do not need to wait until actuator stops running to disconnect. ZTH-GEN disconnect tool (ES) (ES) Advanced Mode Enter the configuration menu by pressing OK (hold button) while connecting the ZTH-GEN US to the actuator. Step through with arrow key to Advanced Mode menu hange mode from 0 to 1 Unplug the ZTH-GEN US With advanced mode, change runtime, control signal (2-10 V, 0-10 V). (ES) 42
Products no longer available
Technical ata sheet R6..R haracterize control valves, 2-way, with flange PN 6 for open an close col an warm water systems for moulating control on the water sie of air-hanling an heating systems air bubble-tight
Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch
echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data
225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225C-024T-05 Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations.
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,
Frequently Asked Questions
Frequently Asked Questions System and Valve Basics: 1. Q: What is good cooling coil performance? A: The temperature range is controlled within +/- 0.5 F (0.28 C) off the cooling coil at set point or below.
Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL
BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
VG2000 Series Cast Iron Flanged Globe Valves
VG2000 Series ast Iron Flanged Globe Valves Installation Instructions Part No. 14-1161-106, Rev. Issued November 15, 2013 Supersedes June 15, 2007 pplications VG2000 Series ast Iron Flanged Globe Valves
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL
N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,
Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95
Actuators Technical data sheet 227S-230-05-S1 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection. www.usa.siemens.
2012 Valve & Valve Actuator Catalog For new construction or retrofits, simplify projects with our complete selection. www.usa.siemens.com/hvac Our dynamic duos provide comprehensive control. Fast installation
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Type overview. Technical data
Technical data sheet R3..xx-S.. Characterised control valve, 3-way, Internal thread For closed cold and warm water systems For modulating water-side control of air handling units and heating systems ir
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
How To Drive A Compact Serie 1
Electric lifting cylinder Compact Series Table of Contents Glossary... 2 Compact serie SR 1... 4 Dimension SR 1... 5 Compact Serie SR 1SP... 6 Dimension SR 1SP... 7 Compact Serie SR 5... 8 Dimension SR
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Know-how makes the difference. Electrical Actuators
Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.
Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid
DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing
Technical data sheet R5.. Characterized control valves, 3-way, with external thread for open and closed cold and warm water systems for modulating control on the water side of air-handling and heating
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling
Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Baumann 81000 Mikroseal Control Valve
Product Bulletin D103340X012 Baumann 81000 Mikroseal Control Valve The Baumann 81000 Mikroseal control valve (figures 1 and 2) is excellent for throttling of liquid or gaseous media, particularly where
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Overview of types. Technical data
Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight
Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009
Applying Pressure Independent Control Valves in H.V.A.C. Systems A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009 1 Introduction I know, as building design consultants, so much of your effort
Butterfly Valves PN 6/10/16 for flanged connection
4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40
Compressor Service & Maintenance Manual
Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance
System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors
European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
G670 Intermittent Pilot Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.
Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on
Install Guide 3M-50. Caution. Caution
PG 1 Install Guide 3M-50 aution Your thermostat is a precise instrument, handle it with care. Turn off electricity to the HVA system before installing or servicing thermostat or any part of the system.
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE
EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE User manual v1.5 Compatible with: ESIM264 v7.09.02 and up. ESIM364 all versions. Main features: Hardwired zone expansion adding 16 additional zones per
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
T5000 T000 LCD Digital Fan Coil Thermostat
T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
IOM SERIES 820-E/P Electro-Pneumatic Positioner
FLUID CONTROL DIVISION Parker Hannifin Corporation 95 Edgewood Avenue New Britain, CT 06051 Telephone (860) 827-2300 IOM SERIES 820-E/P Electro-Pneumatic Positioner INSTALLATION, OPERATING & MAINTENANCE
% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
How To Control A Motorized Motorized Power Control (Motorized Motor Control) (Mft)
Technical Documentation Multi-Function Technology (MFT) for Damper and Control Valve Applications Effective May 2010 Multi-Function Technology Your swiss army knife for HVAC. We set standards. www.belimo.com
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Fluxi 2000/TZ Turbine Gas Meter
Gas Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas.
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Specification Data CM37002 09/10. Putting You In Control. 37002 Series MiniTork ll Control Valves. Heavy Duty Control Butterfly Valves
Putting You In Control Specification ata CM37002 09/10 37002 Series MiniTork ll Control Valves Heavy uty Control Butterfly Valves resser Masoneilan 37002 Series MiniTork II Control Valves Heavy uty Control
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction: