WBIA Industry Days Recovery Boiler Presentation Appleton, WI.
|
|
|
- Grant Taylor
- 10 years ago
- Views:
Transcription
1 WBIA Industry Days Recovery Boiler Presentation Appleton, WI. Presented by Bob DeCaigny April 24, 2013
2 Objectives 1. Kraft recovery cycle overview 2. Recovery boiler explosion history (25 events in 28 years) 3. What Operators can do to reduce risk of a smelt/water reaction a. Pressure part leak detection b. Follow protocols and procedures c. BLRBAC and AF&PA recommendations 4. Design improvements 5. Where Inspectors can look
3 Kraft Recovery Cycle
4 Review of RB Explosions 25 RB explosions with damage in past 28 years in North America; 1/year from 1984 to 2012 The majority are caused by pressure part leaks or mechanical failures. About half involve the inability to recognize the leak followed by a hot restart. If 100 RB incidents/year (estimated that only 70% of all incidents are reported), then 99% of RB incidents do not result in an explosion (due to leak location, conditions, proper operator action or luck) 1984 there were 350 RB s in service; now less than 200: o New large RB s replace several smaller units o Mills shut down, companies merge & some capacity moves overseas
5 BLRBAC RB Explosion Data
6 RB Explosion Sources (50 years--usa & Canada) 's 70's 80's 90's 00's Pres. Pt. Blk. Liq. Aux. Fuel Spout Other
7 Smelt-Water Reaction Smelt bed temperature is >1500 F Water that contacts the bed expands very rapidly as it boils, increasing 1500 times in volume, creating a very large shock wave Steps in a RB that lead to a S-W reaction (explosion): Water comes in contact with smelt Some event triggers mixing of some of the smelt and water Water that intimately mixes with the smelt vaporizes rapidly, resulting in a shock wave that intimately mixes additional smelt & water The additional smelt-water mixing leads to a much larger shock wave (explosion)
8 Smelt-Water Reaction
9 Review of RB Explosions When reviewing each incident, ask; o What was done right? o What went wrong? o How are the RBs you are involved with protected from this type of incident occurring? o Do any RB procedures, practices, configurations or designs need to be modified to prevent a similar incident?
10 Recent RB Explosions (S-W) 1. Unit brought on line, spout cooling water valve closed, spout failed resulting in moderate damage and two weeks of downtime. Event led to BLRBAC recommendation to eliminate valves on spout cooling discharge and later for logic to prove smelt spout cooling flows OK prior to start-up. Moderate damage, down two weeks. 2. Unit shutting down, washing out BL ring header, gun left in furnace resulting in major damage requiring five months of downtime. Event led to BLRBAC recommendation to install BL gun gates which are interlocked to the header wash logic. Major damage, down five months. 3. Lost cooling water flow to the spouts (for some time?) and when reestablished a mild explosion occurred with minor damage. Event led to BLRBAC recommendation to refrain from putting water back into a spout once it has been lost. Minor damage, downtime unknown.
11 Recent RB Explosions (S-W) 4. Operating normally, explosion occurred. Rear wall tube failure due to corrosion at membrane. Defect not picked up through previous NDT efforts. Event led to BLRBAC recommendation to NDT test at three points at each site (crown and two at membrane). Also, use composite tubing on RB s higher than 600 psig. Major damage, down five months. 5. Restart of RB following downtime to repair ESP for gen section tube leak. While down changed out the FW control valve. On start-up having trouble controlling the FW, RB tripped on low drum and turbine driven FWP tripped. Started the motor driven FWP which is ½ capacity, defeated low drum trip brought RB up. 20 minutes later FD fan tripped on high furnace pressure, heard loud noise followed by a rushing sound. ESP d within three minutes, screen tube rupture. Event led to company developing a companywide RB operator training and testing program. Their program was later given to the AF&PA. Major damage, down five months.
12 Recent RB Explosions (S-W) 6. Limited information due to severity of event crews suspected a leak, called superintendent, delay of 30 minutes while waiting for him, they continued investigating, severe explosion involving fatalities. RB a total loss and Mill shutdown permanently. Extreme damage, Mill down permanently. 7. Unit operating for about two months after a month long outage to replace the gen bank. High furnace pressure trip, restarted fans and relit. Heard a hissing noise and ESP d. 11 minutes later a second more severe explosion, followed by a third more severe explosion. Ruptured screen tube. Found chemical attack on tube potentially from previous retube job chemical cleaning or foreign material left in boiler resulted in inhibited circulation and steam blanketing. Moderate damage, down two months. 8. RB tripped on high furnace pressure. Operators restarted unit and it exploded. Gen section tube sheared at mud drum (near drum corrosion), thrust into furnace, hung up on a SH tie and hosed the bed with water. Moderate damage, down five weeks.
13 Recent RB Explosions (S-W) 9. Two months earlier unit was down to repair a rear wall tube failure at the smelt line ESP d with no explosion. At that time found 200 thinned tubes which were replaced. The unit had a history of long layups with no fireside cleaning. Difficulty performing effective NDT near membrane. While shutting down for scheduled maintenance firing oil and heard a loud bang. Saw dark bed area, moisture at PA ports and water leaving the spouts. Tried to ESP but system and fans tripped due to heavy building vibration when explosion occurred. Reset ESP and initiated 17 minutes later. Split on bottom of one of spouts (in service five months). Minor damage, down two days. 10. Incomplete information, could also be fuel related. Operating normally with six BL guns, four S/U oil and three load oil burners. BL divert system in bypass (needing to circulate BL to DCE?). BL burning poorly with ineffective pressure and temperature control attributable to secondary BL heater blowing through. Pulled BL from boiler, got unit under control and when adding BL back in explosion (low BL solids/pyrolysis gas/s-w?). Moderate damage, down one month.
14 Recent RB Explosions (S-W) 11. No information on event. Extreme damage, fatalities and mill permanently shutdown. 12. Stopped firing BL due to inventory. Did a BL ring header wash and left gun in. Explosion. Major damage, downtime unknown, Mill has since S/D. 13. Trouble getting BL through the DCE, solids dropping and BL divert conducted. Load burners tripped on low drum level. Conducted a hot restart and heard a rumble then an explosion. Two floor tubes had failed and ten others were blistered (water chemistry issue?). Had been possibly leaking for up to one month before event. Moderate damage, downtime unknown. 14. Water washing the boiler without first sufficiently cooling the bed. Event led to BLRBAC recommendation to cool the char bed to <800 ºF and probe temperature with thermocouples prior to water washing. Moderate damage, downtime unknown.
15 Recent RB Explosions (S-W) 15. Sootblower stuck about mid-travel in the rear wall screen lane. Mechanics delayed in responding and eventually removed the sootblower from the boiler. High furnace pressure trip, drum level low and using 250 mpph FW to maintain level. Got back on line burning BL, furnace pressurizing and found ruptured SH tube. Burning out bed for shutdown (steam 240 mpph, FW 450 mpph) and discovered something wrong. Open RB rapid drains but, did not ESP. 15 minutes later FW >700 mpph, tripped two motor driven FWPs but, the turbine driven pump required a manual local trip. Explosion. The walls bulged and explosion corner opened up. Minor damage, down one week.
16 S-W Event #15 Pictures
17
18
19
20
21
22 Recent RB Explosions (S-W) 16. ID fan speed increasing, drum level dropping, FW control in manual 96% open to reestablish drum level and FW back in auto. MFT for high furnace pressure, FW in auto and drum level dropping. Reestablished drum level and attempting restart when two loud explosions heard. ESP d. PLC fault drove SB in for 3.5 hours and sheared a gen section tube at steam drum. Replaced floor, beams, all buckstays and some wall panels. Major damage, down four months. 17. BL unstable burning, noise at char bed from BL gun slag, walkdown and no leak detected. 7.5 hours later unit trips on low drum, bring back on line. Two hours later low drum trip, ID fan speed has increased by 30% and FW open 100% in manual. Reestablish drum, light an oil burner, loud explosion and ESP d. Leak at right floor to sidewall seal plate (DWD 90 g./ft. 2 ), all corners opened one to two feet (no explosion corner), floor separated 8 feet and the building steel was damaged. Extreme damage (fatalities and serious injury), Mill permanently shutdown (900 people).
23 S-W Event #17 Pictures
24
25
26
27
28
29
30
31
32
33
34
35
36
37 Recent RB Explosions (S-W) 18. The primary air ports had been blacking out, checked it out and declared OK. Next shift heard a pop followed by an explosion. ESP d. Leak at RHSW PA level. Replaced four tubes. Last chemical cleaning 22 years prior. DWD factor? Minor damage, down four days. 19. Had been operating normally when a large concussion was felt and an explosion heard. Saw smoke out of the spouts and smoke throughout the building. Attempted to ESP, pressure did not drop so shutdown equipment manually and this was followed by a second more violent explosion. Believe a large amount of ash slag fell from the roof and sheared screen tubes. Major damage, down one month.
38 Recent RB Explosions (Pyrolysis Gas) 1. Start-up burner ignited pyrolysis gas from BL being sprayed into boiler while not burning. Event led to BLRBAC recommendation for start-up logic requiring a minimum hearth heat input (steam flow or number of start-up burners in) prior to permitting BL firing. Moderate damage, downtime unknown. 2. Primary and secondary combustion air fans tripped which initiated a MFT. BL continued to fire due to obsolete C-E logic to quench the bed with BL after MFT still in effect, even though thought by Mill personnel to have been previously removed. RB purged for 5 minutes and when the first gas burner was lit a slight explosion occurred resulting in bulged walls. Minor damage, down 4 days. 3. RB on line and had a high furnace pressure trip. Conducted a hot restart with difficult drum level control. Readmitted BL and explosion occurred.
39 Recent RB Explosions (Pyrolysis Gas) 3. RB on line and had a high furnace pressure trip. Conducted a hot restart with difficult drum level control. Readmitted BL and explosion occurred. Unit ESP d. Question whether the BL divert system was available and functioning normally. Minor damage, down 10 days.
40 Recent RB Explosions (Comb. Gas/Aux Fuel) 1. RB was being fired on BL and the BL solids tests done every 30 minutes were within the acceptable range. The BL divert system was bypassed at this time due to a third RB off line for a SH tube leak. BL flow interrupted (pump KO?). BMS logic designed such that if an ignitor pilot is established prior to <25% outlet steam flow, no purge is required. Several attempts to light oil burners failed, so tried BL. Explosion. ESP failed to activate, manually drained boiler. Found WBL backed up from BL dump system into cascade DCE. Moderate damage, down two months.
41 Recent RB Explosions (Comb. Gas/Aux Fuel) 2. New unit in the process of being commissioned. Firing natural gas, had never seen BL firing. BMS not fully commissioned, e.g., flame scanners not tuned, maximum gas pressure and trip not operating properly, etc. Firing four LBs to support Mill load and steam header swing caused 3 of 4 LBs to trip. Since the one in service LB was on flow control as each LB tripped more gas was added until the last LB was beyond its design capacity resulting in unburnt fuel accumulation which exploded when the adjacent LB was relit. Unit has an explosion corner. Moderate damage, down two months. 3. Cold outage, power boilers down, package boiler in to run 400# fans with 150# steam for recovery start-up. Unit not up fully with stable headers and sent 80# steam to the evaps, explosion. Start-up burners have Class I ignitors (20% capacity) with separate combustion air and no main flame monitoring. Starved fans, speed dropped and combustibles accumulated. Extreme damage (one fatality and multiple burns), down eight months.
42 Comb. Gas/Aux Fuel Event #3 Pictures
43
44
45
46
47 RB Explosion History Conclusions 25 RB Explosions over 28 years ( ) of those events 18 involved mistakes/lapse of judgment (training, expectations, procedures, operators not empowered, production pressures, etc.) 9 involved hot restarts 5 led to BLRBAC recommendations Damage 6 minor 9 moderate 6 major 4 extreme
48 RB Explosion Data Analysis The data clearly shows that there are 3 steps leading to the majority of recent catastrophic RB explosions with severe damage: Eliminate any step (link in the failure chain) and an explosion does not occur! 1 st Step--A large pressure part leak occurs. 2 nd Step--RB operators do not recognize or react properly to the indications of a major pressure part leak. 3 rd Step--RB operators proceed into a hot restart. A smelt-water EXPLOSION occurs.
49 RB Hot Restart They said that they were attempting a hot-restart following a low drum level/high furnace pressure trip when
50 What Operators Can Do (To Reduce the Chance of a RB Incident) Be sensitive to the dangers of a hot restart Use all leak detection tools Participate in Audits Utilize BLRBAC and AF&PA resources
51 RB Production Pressure This is a major factor in quickly attempting a HOT RESTART following a RB trip. Half of RB explosions occur during hot restarts. Stop and ensure there are no pressure part leaks prior to a hot restart. Other industries also experience these same production pressures.
52 Pressure Part Leak Detection Although much reduced from previous years, pressure part leaks are still the major cause of smelt-water explosions that damage RB s. Hot restarts (with leaks) led to half of the explosions. BLRBAC Incident Reports consistently show that 2/3 of all pressure part leaks are 1 st detected at the boiler by field checks, before RB instrumentation detected the signs of a leak.
53 Leak Detection at the Boiler Puffing or blowback Blowing or hissing sounds with the SB s off Dark spots in the char bed Unusual noise from the char bed Water, steam, or damp spots on lagging/casing Water or dampness in the ash hoppers or conveyors Water or dampness in the PA or SAr ports or ducts Water overflowing the air duct low-point seal pot
54 Leak Detection from Control Room Instrumentation Unexplained decrease in CBD conductivity or PO 4 residual Unexplained increase in ID fan speed Unexplained high furnace pressure or trip Unexplained low drum level or trip Erratic draft readings Unexplained decrease, imbalance, or erratic temp. indications in the boiler bank or economizers Sudden increase or decrease in drum level Significant changes or differences in the steam & FW flow rates High motor loads or trips of the ash feeders or conveyors Unexplained drop in BL % solids
55 What Operators Can Do (To Reduce the Chance of a RB Incident) Follow protocols, procedures and be empowered to act (management owns the larger part of this) Be aware of five ways to wreck a RB
56 Five Ways to Wreck a RB 1. Don t Protect the Superheater 2. Don t Protect the Large Economizers 3. Don t Follow the Start-up Curve 4. Provide Poor Feedwater & Boiler Water Quality 5. Don t Check for a Pressure Part Leak BEFORE Attempting a HOT RESTART
57 1. Protect the Superheater Hydro; Backfill with demineralized water Start-Up; Boil out elements before flue gas >900ºF Operation; Limit load, balance firing, attemperate steam temp. to operate within allowable SH metal temps. Trip or Shutdown; Open SH vent to ensure steam path cooling until flue gas is <900ºF Chemical Cleaning; Backfill the SH between cleaning stages
58 2. Protect the Economizer Filling; FW max. temp. is eco metal temp F. Start-Up; Stay on the curve; too long can boil the hot economizer. Don t boil Eco2. Keep FW outlet <20F of the steam drum saturated temp.; vent SH or blow down drum enough to cause some FW flow. Water Washing; Ensure hard salt deposits are washed from between the outer eco elements & the eco sidewall casing. Outages; Inspect to ensure eco lower header/hopper expansion joints are clean to allow motion.
59 3. Follow Start-Up, Cooldown, & Hydro Curves Start-up; Maximum temperature (pressure) rise rate = +100 F/hr. (~ 5.2 hrs. 75F 595F[1500#]). Cooldown; Maximum rate = -100 F/hr. Hydro; Maximum water temperature = +100 F above drum or economizer metal temps. Hydro; Maximum pressure rise & decrease rates: # = +100 #/min. (normal hydro) 1250# 1875# (1.5 x oper.) = +50#/min. 1875# 2510# (1.5 x design*) = +15#/min. (major pressure part work) Design pressure = 1675#
60 1500 psig Start-up/Cool-down Curve
61 4. World Class Water Quality Treated Water Quality Condensate Quality Deaerator Operation Feedwater Chemistry ph, O 2 scavenger, etc. Blowdown Control Silica, Alkalinity, Conductivity
62 5. Hot Restart (BLRBAC recommendation) Following a MFT for HIGH furnace pressure and a LOW drum level condition: An alarm will announce a Possible Leak. DCS will drive FW control valve closed and autoswitch control mode to manual. RB operator MUST check & verify no furnace pressure part leak PRIOR to readmitting FW to re-establish drum level.
63 BLRBAC and AF&PA Recommendations ESP system BL refractometers and divert logic Burner management systems DCE fire suppression systems Waste streams protections Liquor gun gate logic
64 BLRBAC and AF&PA (continued) Annual spout replacement and hydros Incident reports and audit programs RB Operations seminars RB Operator refresher training Upset/Emergency procedures
65 Recovery Boiler Safety Audit
66 RB Design Improvements Mid-furnace explosion relief corners Improved SH metallurgy (higher temp.) Improved SH tie-clip & roof seal designs SWC for SH attemperation vs. FW Improved FW & condensate treatment; RO, polishers, online sensors, etc. Single-drum vs. 2-drum w/rolled tubes No furnace screens or improved screen design Improved circulation design, corners, etc. Greater margins for circulation stability
67 RB Lower Furnace Corrosion Rate vs. Pressure (Temperature)
68 Corrosion Protection
69 Furnace Floor Design
70 Furnace Corner Design
71 Buckstay/Explosion Corner
72 SH TC Location on Outlet Tubes
73 SH Thermocouples at Start-up
74 SH Thermocouple Graphic
75 SH DCS Graphic
76 Roof & SH Support Design
77 SH Cooling Loop, Sec. & Tert.
78 RB Heat Absorption vs. Pressure
79 2-Drum vs. 1-Drum Circulation
80 Furnace Screen Design
81 RB Design Improvements (continued) Improved ASME code welder testing/certification 100% radiograph of pressure part welds SB water washing system Improved NDT technology Vacuum spout cooling systems & dry spouts (?) Extra dissolving tank stack explosion relief systems DCS inst. & controls vs. analog; reliable CO meters; char bed CCTV cameras Leak detection systems BL concentrator technology vs. DCE
82 Where Inspectors Can Look Due to extreme consequences which can result from a smelt-water reaction and corrosive nature of sulfur gasses and liquids found in recovery boilers, the following areas require attention beyond what is normally given to a power boiler; 1. Thorough NDT of the fireside pressure parts; UT, MLO, PT, Shear- Wave, CuSO 4 2. Thorough visual inspection of the pressure parts and refractory 3. Inspection of the underside of the floor for signs of smelt leaks 4. Annual replacement of the water cooled smelt spouts; inspection of the spout tube openings 5. Waterside inspection of the lower furnace, furnace screen and generating bank headers
83 Where Inspectors Can Look (continued) 6. Regular removal of a tube sample from lower furnace high heat flux zone for FW/BW quality and DWD analysis 7. Complete functional testing of the ESP system annually 8. Functional testing of the low BL % solids divert system annually 9. Replacement of pressure parts that have <0.020" above ASME tube MWT remaining 10. Inspect RB mid-furnace explosion corner 11. Inspect and verify functionality of scrubber by-pass (primary explosion) damper and dissolving tank secondary explosion dampers, if equipped
84 Summary RB s are better designed, operated, & inspected, but pressure part leaks still occur. Pressure part leaks are the largest factor in smelt-water explosions. There are about 100 RB leaks/yr. (N. Am.); only 1% result in an explosion (~1/yr.). 2/3 of RB leaks are 1 st detected at the RB (operator walkdowns). Half of RB explosions occur during hot restarts. Hot restarts (w/o 1 st ensuring no leak) are driven by production pressures. Trained responses (ESOP s) to an emergency condition greatly reduce improper actions which can lead to RB explosions.
85 Questions?
Routine and Emergency Boiler Operation
Routine and Emergency Boiler Operation Learning Outcome When you complete this module you will be able to: Describe the routine safe and efficient operation of a packaged boiler. Learning Objectives Here
OPERATIONS & MAINTENANCE SUBCOMMITTEE RECOVERY BOILER SAFETY AUDIT GUIDELINES
AMERICAN FOREST & PAPER ASSOCIATION AMERICAN FOREST & PAPER ASSOCIATION OPERATIONS & MAINTENANCE SUBCOMMITTEE RECOVERY BOILER SAFETY AUDIT GUIDELINES March 1990 Revised July 2004 Revised May 2012 893 McLean
Boiler Preparation, Start-Up and Shutdown
Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.
A Primer on Protecting Idle Boilers By Howard Benisvy, Member ASHRAE
The following article was published in ASHRAE Journal, December 2002. Copyright 2002 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. It is presented for educational purposes
Boiler & Pressure Vessel Inspection discrepancies and failures
Boiler & Pressure Vessel Inspection discrepancies and failures Water Heaters / Pressure Vessels Pressure Vessels are inspected once every three years. This requires a test of A: safety relief devices B:
OROT RABIN POWER STATION UNITS 1-4. 4 x 350 MW
ISRAEL ELECTRIC OROT RABIN POWER STATION UNITS 1-4 4 x 350 MW COAL BOILER CONVERSION TO LOW NO X NATURAL GAS AND COAL FIRING BY PRIMARY AND SECONDARY MEASURES INSTALLATION Replacing the Burner Management
I. STEAM GENERATION, BOILER TYPES
I. STEAM GENERATION, BOILER TYPES and BOILER PLANT SYSTEMS 1 Steam Generation Water s Unique Properties: High Thermal Capacity (Specific Heat) High Critical Temperature Ideal Medium for Heat Delivery High
INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9
TABLE OF CONTENTS Description Page Number SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9 Indeck Keystone Energy, LLC. 5451 Merwin Lane, Suite 100 Erie,
Preventing Overheated Boiler Incidents
Preventing Overheated Boiler Incidents PSE&G Appliance Service October 2012 Runaway Boiler Explosion Review Items Hazard Background Past Incidents PSE&G Emergency Response Future Process Improvements What
Basics of Kraft Pulping & Recovery Process. Art J. Ragauskas Institute of Paper Science and Technology Georgia Institute of Technology
Basics of Kraft Pulping & Recovery Process Art J. Ragauskas Institute of Paper Science and Technology Georgia Institute of Technology Outline History Goals Process Overview Kraft Pulping Process Kraft
Recovery Boiler Combustion control system(ccs) & Emergency shutdown(esd).
Insert Photo Here Recovery Boiler Combustion control system(ccs) & Emergency shutdown(esd). Mario López Jorge Quesada Rockwell Automation Process Solutions User Group (PSUG) November 14-15, 2011 Chicago,
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
Boiler and Burner Cleaning and Servicing Specifications
Boiler and Burner Cleaning and Servicing Specifications The Town of Groton of Public Works Department is requesting bids to provide manufacturers recommended maintenance, repairs and emergency service
Steam System Efficiency. Bill Lumsden Leidos Engineering
Steam System Efficiency Bill Lumsden Leidos Engineering Steam System Efficiency Steam System Efficiency Key Take-aways: Review of the properties of ice, water, and steam Learn the basics of steam trap
steam centre of excellence Steam Boiler System Optimization
Steam Boiler System Optimization Introduction Gas Cost Metering Fluids Fuel, Water, Steam Steam Costs Boiler House Stack Losses Boiler Waterside Surfaces Blowdown Current Natural Gas Cost Projected Cost
Department of Veterans Affairs VHA DIRECTIVE 2008-062 Veterans Health Administration Washington, DC 20420 October 15, 2008 BOILER PLANT OPERATIONS
CORRECTED COPY Department of Veterans Affairs VHA DIRECTIVE 2008-062 Veterans Health Administration Washington, DC 20420 BOILER PLANT OPERATIONS 1. PURPOSE: This Veterans Health Administration (VHA) Directive
Action Plan Template HVAC Page 1
Action Plan Template HVAC Page 1 Once Establish expected HVAC system efficiency - Write down the expected efficiency of HVAC systems to use as a baseline - Add this information to maintenance plan documentation
Backup Fuel Oil System Decommissioning & Restoration Plan
Backup Fuel Oil System Page 1 of 19 Overview of Physical Fuel Oil System and Decommissioning Steps The fuel oil system at Milford Power consists of a number of subsystems. These include the following:
ELECTRODE BOILERS VAPOR POWER INTERNATIONAL
ELECTRODE BOILERS WITH JET-FLO Technology VAPOR POWER INTERNATIONAL ELECTRODE boilers The Electrode Steam Boiler with Jet-Flo technology consists of an insulated pressure vessel and is fully enclosed in
Efficiency on a large scale CFB Steam Boilers
Efficiency on a large scale CFB Steam Boilers Circulating Fluidized Bed Steam Boiler The Circulating Fluidized Bed Steam Boiler is an offering from Bosch Thermotechnology a member of the worldwide Bosch
Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE
Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance
HOW TO SELECT A LOW VOLUME (L.V ) BOILER
HOW TO SELECT A LOW VOLUME (L.V ) BOILER FREQUENTLY ASKED QUESTIONS OR COMMENTS ON BOILERS Dear Potential Customer: Low Volume Operator Exempt boilers have been marketed in Ontario to eliminate the requirement
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
HAZARD RISK ASSESSMENT
HAZARD RISK ASSESSMENT Mt Grace Batchelor Magnesium Project A hazard risk assessment was undertaken to identify and assess the consequences of unplanned incidents that may pose safety, environmental risks,
Energy Efficient Operations and Maintenance Strategies for Boilers
Energy Efficient Operations and Maintenance Strategies for Boilers Large, complex and widely used, industrial boilers are major consumers of fuel. Proper operations and maintenance (O&M) procedures must
Your Boiler Room: A Time Bomb?
Your Boiler Room: A Time Bomb? Is you boiler room a potential Time Bomb? A few basics you need to know to work safely in the boiler room: Two potentials for explosions in a boiler room: Water/steam side
Condensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference?
Photo By: Steve Spak December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference? What is a backdraft explosion and how does differ from a flashover? Explosions kill and injure
Some Criteria for Choosing a Steam Boiler for a Microbrewery
Some Criteria for Choosing a Steam Boiler for a Microbrewery Jack Coe Rite Engineering and Manufacturing Corporation Breweries rely on steam heating for a number of functions, primarily to heat the brew
World Class Water Chemistry By Accident? BRO Chemistry Session 8/5/2014
World Class Water Chemistry By Accident? BRO Chemistry Session 8/5/2014 From Safe by Accident? by Judy Agnew & Aubrey Daniels Despite decades of reduction in safety related deaths and injuries on the job,
Recovery Boiler Research Needs An Industry Perspective
Recovery Boiler Research Needs An Industry Perspective Andrew Jones International Paper 7th International Colloquium on Black Liquor Combustion and Gasification International Paper Recovery Operation Goals
Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs
Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers Michael Pace Lead Engineer C & I Efficiency Programs Agenda Energy Efficiency Opportunities for Small/Mid Commercial Facilities
Energy Saving Solutions. Bob Montgomery Technical Solutions Specialist Waterloo Manufacturing
Energy Saving Solutions Bob Montgomery Technical Solutions Specialist Waterloo Manufacturing Combustion Efficiency Measure Heat Recovery Energy Saving Solutions Upgrade Repair Replace Audits Financial
The soot and scale problems
Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications
Originators of the Flexible Water Tube design
BRYAN FLEXIBLE WATER TUBE AB SERIES STEAM AND WATER BOILER 900,000 TO 3,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler AB120-W-FDGO Steam Boiler AB250-S-150-FDG Originators of the Flexible
C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).
SECTION 23 52 30 PART 1 - GENERAL 1.01 RELATED WORK A. Section 23 05 00: Common Work Results for HVAC B. Section 23 25 00: Chemical Water Treatment C. Section 23 51 23: Flue Piping 1.02 QUALITY ASSURANCE
Rules for construction of heating boilers, Boiler and Pressure Vessel Code, Section IV-2007
Boilers Introduction How Boilers Work Types of Boilers Key Components of Boilers Safety Issues Best Practices for Efficient Operation Best Practices for Maintenance References Introduction Boilers are
Job Grading Appeal Decision Under Section 5346 of Title 5, United States Code
U.S. Office of Personnel Management Office of Merit Systems Oversight and Effectiveness Classification Appeals and FLSA Programs Dallas Oversight Division 1100 Commerce Street, Room 4C22 Dallas, TX 75242
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
Water-Tube Package Boilers Reliable and Economical Steam Production
Water-Tube Package Boilers Reliable and Economical Steam Production Water-Tube Package Boilers: Proven Design for Economical Steam Production Since 1867, The Babcock & Wilcox Company (B&W) has been designing,
Steam Generation Efficiency Module Blowdown Losses Section
Steam End User Training Steam Generation Efficiency Module Blowdown Losses Section Slide 1 Blowdown Losses Module This section will discuss blowdown loss and its affect on boiler efficiency. [Slide Visual
Evaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.
Pellet Heater Owner's Manual Installation and Operating Instructions Please read this entire manual before installation. Save these instructions. SAFETY NOTICE HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
PC1130 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
Recover Heat from Boiler Blowdown Water
Prepared for California Energy Commission (CEC) Prepared By: Southern California Gas Company (A Sempra Energy Utility) E3M Inc. May 2012 i Disclaimer The CEC and its contractor, Southern California Gas
PC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
Table Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS
TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS Dr. Abhay Kumar Sahay, AGM(CC OS) Bijay Manjul, AGM( Operation) Kahalgaon Boiler has three inputs Steam generator 1. WATER 2. COAL 3. AIR Burner Air preheater
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
C. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
IGEMA BOILER LEVEL & TDS CONTROLS
IGEMA BOILER LEVEL & TDS CONTROLS IGEMA offers boiler level and TDS control products of the highest quality standard, being certified to ISO 9001. Made in Germany, IGEMA products are manufactured in compliance
GeniSys 12V. Model 7556. Description / Applications. Advanced 12 Vdc Burner Control
PARTS & ACCESSORIES GeniSys 12V Model 7556 Advanced 12 Vdc Burner Control Description / Applications The Beckett GeniSys TM 12V Advanced Burner Control is a 12 Vdc primary safety control for oil burners
MOSS WOOD BOILER SYSTEMS
GEORGE K. MOSS CO., INC. INSIDE THIS ISSUE: WOOD WATER T U- TUBE BOILER WOOD FIREBOX BOILER WOOD HYBRID BOILER GASIFIER COM B- BUSTION SYS- TEM PNEUMATIC COMBUSTION SYSTEM WOOD BOILER PLC CONTROLS PLC
RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
How To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant
Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Health and Safety Safe management of industrial steam and
GUIDELINES FOR LOGBOOKS COMPLIANCE TO BOILER REGULATIONS N.J.A.C. 12:90
GUIDELINES FOR LOGBOOKS COMPLIANCE TO BOILER REGULATIONS N.J.A.C. 12:90 Department of Labor and Workforce Development Labor Standards & Safety Enforcement Division of Public Safety and Occupational Safety
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.
Demystifying HVAC Test Your HVAC Knowledge By Ron Prager How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page. 1)
Baxi Combi 80e & 105e
Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural
KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM
KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...
Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling
Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Diagnostics for Mobile Homes: HVAC
Diagnostics for Mobile Homes: HVAC Adam Harris NYSWDA Wade Thompson - IWTC Objectives Identify different types of HVAC used in mobile homes Provide an overview of duct systems Demonstrate various tests
NYC Department of Education Building Condition Assessment Survey 2014-2015 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004
School: InspectionId Asset Data Inspection Type Building Assessment Survey 204-205 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 0004 Time In Last Edited 255 MECHANICAL 205-05-8 09:00AM
Safe Method: Gas Safety in Catering Establishments
Safe Method: Gas Safety in Catering Establishments Safety Point Why? What do you do? Gas equipment and services must only be installed, maintained and repaired by a Gas Safe registered installer. Check
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...
Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas
Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas Mark Schiffhauer, ATSI Engineering Services Cameron Veitch, Combustion and Energy Systems Scott Larsen, New York State Energy
This section gives you some helpful information and tips on running your home and the equipment in it.
67 This section gives you some helpful information and tips on running your home and the equipment in it. Electricity Fuse board (electrical consumer unit) Make sure you know where your fuse board is and
WATER WALL BOILER FOR AIR AND OXYGEN FIRED CLAUS SULPHUR RECOVERY UNITS
WATER WALL BOILER FOR AIR AND OXYGEN FIRED CLAUS SULPHUR RECOVERY UNITS Abstract Mahin RAMESHNI, P.E. Technical Director, Sulphur Technology [email protected] WorleyParsons 125 West Huntington
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
Best Practice in Boiler Water Treatment
Best Practice in Boiler Water Treatment Boiler Water Treatment Part 2 Internal Treatment Objectives of Internal Water Treatment 1 To control the level of total dissolved solids (TDS) within the boiler
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES
HC900 for Boiler Control Applications
HC900 for Boiler Control Applications Background Until recent years, only the largest boilers could justify sophisticated boiler controls. Now high fuel costs make it necessary to improve boiler efficiency
THREE. Heating and Cooling
THREE Heating and Cooling 17 Condensation Drain Line The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. If your unit is located in the attic,
Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng
Condensing Economizers Workshop Enbridge Gas, Toronto MENEX Boiler Plant Heat Recovery Technologies Prepared by: Jozo Martinovic, M A Sc, P Eng MENEX Innovative Solutions May 15, 2008 MENEX INC. 683 Louis
PLP - TERMS AND CONDITIONS
PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia
CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!
CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different
Troubleshooting HVAC/R systems using refrigerant superheat and subcooling
Troubleshooting HVAC/R systems using refrigerant superheat and subcooling Application Note Troubleshooting and servicing refrigeration and air conditioning systems can be a challenging process for both
By K.K.Parthiban / Boiler specialist / Venus Energy Audit System
FINE TUNING EXPERIENCE OF A CFBC BOILER By K.K.Parthiban / Boiler specialist / Venus Energy Audit System Introduction The Industrial boilers have been seeing a growth in capacity in the recent years. Current
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Annual Service Agreement
Annual Service Agreement 462 Main Street P.O. Box 130 Royersford, PA 19468 610-948-7220 www.plottsenergy.com GAS OIL HEAT PUMP AIR CONDITIONING A family owned and operated business since 1949. We are here
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3
HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- BY MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3 SYNOPSIS JP Steel Plantech Co. has developed Hybrid system for EAF off-gas heat recovery, with EAF
CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS
CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS BULLETIN 240-10-3 June 2004 Supersedes June 1983 Many centrifugal systems get little maintenance. As a result they operate with the refrigerant highly contaminated
WARNING: IMPROPER SERVICING AND START-UP OF THIS EQUIPMENT MAY CREATE A POTENTIAL HAZARD TO EQUIPMENT AND TO OPERATORS OR PERSONS IN THE BUILDING.
START-UP AND OPERATION WATER BOILERS WARNING: IMPROPER SERVICING AND START-UP OF THIS EQUIPMENT MAY CREATE A POTENTIAL HAZARD TO EQUIPMENT AND TO OPERATORS OR PERSONS IN THE BUILDING. SERVICING AND START-UP
2A.1 Features of Chiller Control Components... 104. 2A.3 Chilled-Water Supply Temperature Control... 107. 2A.4 Cooling-Water Supply Control...
Appendix 2A: Chiller Control Principles... 104 2A.1 Features of Chiller Control Components... 104 2A.2 Start-up and Shutdown... 105 2A.2.1 Start-up...105 2A.2.2 Shutdown...106 2A.3 Chilled-Water Supply
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
Guidelines for Preparing for a Temporary Steam Plant
Guidelines for Preparing for a Temporary Steam Plant Trailer-Mounted Boilers Skid Mounted Boilers Mobile Boiler Rooms Mobile Feedwater Vans Mobile Steam Plants Emergency Preparedness Plan Table of Contents
Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla
Helsinki University of Technology Department of Mechanical Engineering Energy Engineering and Environmental Protection Publications Steam Boiler Technology ebook Espoo 2002 Boiler Calculations Sebastian
VACUUM REFRIGERATION SYSTEMS
VACUUM REFRIGERATION SYSTEMS CHILL VACTOR The Croll-Reynolds CHILL-VACTOR is a chiller that uses a vapor flashing process. Water has a pressure-temperature relationship which is its boiling point. If its
University of Iowa Power Plant
University of Iowa Power Plant Contents Purpose... 2 History... 3 Cogeneration... 6 Boilers... 7 Environmental Impact... 10 Steam Turbine Generators... 12 Modernization... 14 Biomass Fuel Initiative...