Network Management System

Size: px
Start display at page:

Download "Network Management System"

Transcription

1 Network Management System Installation & User Guide

2 NMS Feature Description & Operation Issue 1 Revision History ISSUE DATE DESCRIPTION OF CHANGES 1.0a Aug. 08 Initial Release 1.0b Sep. 08 Access Control, System DB, Prompt Upload, System Greeting Copyright 2008 LG-Nortel Co., Ltd. All Rights Reserved This material is copyrighted by LG-Nortel Co., Inc. Any unauthorized reproductions, use or disclosure of this material, or any part thereof, is strictly prohibited and is a violation of Copyright Laws. LG-Nortel reserves the right to make changes in specifications at any time without notice. The information furnished by LG-Nortel in this material is believed to be accurate and reliable, but is not warranted to be true in all cases. LG-Nortel and ipecs are trademarks of LG-Nortel Co., Inc. All other brand and product names are trademarks or registered trademarks of their respective companies.

3 Table of Contents 1. Introduction Overview Feature Summary Installation System Requirements NMS Server Requirements ipecs System & Device Requirements Software Installation Procedure ipecs NMS Software Components Installing Software Components Executing ipecs-nms Application ipecs System Admin Configuration Getting Started Overview of Set-up Checking Windows Service Status Accessing the ipecs NMS Server Using a Web Browser NMS Message Exchange Overview NMS Management Modify Superuser Configuration NMS Server Management NMS Mail Server Configuration Trap Community Configuration System KeepAlive Interval Configuration External Link Configuration User Management User Configuration Set Notification to User Account User Access Control System Management System Configuration System Group Configuration Web Admin Configuration Web Admin Access...48 ii

4 4.4.5 Firmware Upgrade System DB Management Prompt Upload System Greeting Management Reviewing System Info and Status System Info Screen Using System Explorer System Information View Attendant, CO and Station Group Information Views Device Inventory Page System Device Inventory System Group Device Inventory Status Page Device Based Status View CO Channel Status View Station Channel Status View Alarm/Fault Management Alarm/Fault Analysis Screen Event Log Analysis Alarm/Fault Configuration Call Statistics Management Call Traffic Analysis Call Traffic Configuration SMDR Analysis SMDR Statistics DECT Statistics MFIM Statistics DECT G/W Statistics Network Traffic Monitoring Ping Test Traceroute Test Device Network Traffic ipecs Device Ping Test ipecs Device Network Traffic Log & History Management NMS Access Log iii

5 9.2 NMS Operation Log NMS Database Backup & Restore Basic Backup & Restore Basic Backup Operation Basic Restore Operation Entire Backup & Restore Entire Database Backup Operation Entire Database Restore Operation Appendix 1 ipecs System Set-up for NMS...A1-1 Appendix 2 ipecs System Information View...A2-1 iv

6 NMS Feature Description & Operation Issue 1 1. Introduction 1.1 Overview ipecs NMS is a Web-based MS-Windows application software that provides system monitoring and management features communicating with multiple ipecs systems using standard Simple Network Management Protocol (SNMP) for communication across the network. The purpose of this software is to assist in operation of the ipecs systems allowing for convenient and efficient management operation and problem status of the Systems being monitored. The Web-based software architecture provides Network Managers the added benefit of remote accessibility to the NMS server using a Web browser interface for the NMS client. 1.2 Feature Summary ipecs-nms is comprised of three services: NMS Server Management, System Management, and System Monitoring. The following graphic illustrates the features of each, and they are described below: 1

7 NMS Server Management NMS Server Management is for the configuration of common operating parameters of the NMS server and for managing NMS operation history & log. It provides NMS user-related features such as NMS user registration, access control, system assignment and notification configuration. NMS operational history can be checked using the NMS Access Log & Operation Log, and ipecs-nms Control program that is a separate MS-Windows application supporting NMS service-related features such as the execution of the ipecs-nms Service and backup & restore operations on the NMS local database. System Management System Management is for facilitating efficient management & operation of ipecs systems. It provides features for registering ipecs systems to the NMS server, creating system groups, and managing system Web Admin passwords for direct access to ipecs System Web Admin through ipecs-nms. Call Statistics operations present tables and graphs with traffic analysis data for attendant calls, completed calls, CO group calls, and voice mail service requests as well as various tables for DECT statistics information. In regard to Station Message Detail Recording (SMDR) data, the System Management facet of the program additionally provides searching operations in table format for detailed analysis. ipecs device firmware can be upgraded using Firmware Upgrade operations for specified systems at a designated time, and system database, system greeting and prompt files can be uploaded or downloaded. 2

8 System Monitoring System Monitoring provides features for monitoring the operational status of ipecs systems. General system configuration information and detailed device information can be examined, and real-time status information of each device and its channels is also provided. Device channel status information is displayed in either device-based or CO/Station channel-based format. An Alarm/Fault management feature provides information on normal and abnormal system status changes and stores them in a log so that they can be managed by the administrator. Network Traffic Monitoring feature provides a means to monitor network traffic and connection status for general network devices as well as ipecs devices. 3

9 2. Installation 2.1 System Requirements NMS Server Requirements When 20 or less systems are to be registered: CPU Intel Core 2 Duo 2.33 GHz or higher RAM 2 GB or higher HDD At least 4 GB of free disk space O/S Microsoft Windows XP Professional or Windows Server 2003 (32-bit Version with NTFS File System) Display 1280 x 1024 or higher When 200 or less systems are to be registered CPU Intel Dual-Core Xeon 2.4 GHz or higher RAM 2 GB or higher HDD At least 20 GB of free disk space O/S Microsoft Windows XP Professional or Windows Server 2003 (32-bit Version with NTFS File System) Display 1280 x 1024 or higher When 500 or less systems are to be registered CPU Intel Quad-Core Xeon 2.66 GHz or higher RAM 2 GB or higher HDD At least 50 GB of free disk space O/S Microsoft Windows XP Professional or Windows Server 2003 (32-bit Version with NTFS File System) Display 1280 x 1024 or higher ipecs System & Device Requirements MFIM Firmware version 5.0 or higher (ipecs-50/100/300/600) Gateways and IP-phones developed before ipecs Phase 3 can be used for basic NMS features. However, in order to support all the additional features provided by NMS (e.g. ipecs device traffic monitoring), those developed after ipecs Phase 4 should be used, and firmware should be upgraded with latest versions that support NMS features. 4

10 2.2 Software Installation Procedure ipecs NMS Software Components Software components needed for ipecs NMS are: PostgreSQL DBMS (PostgreSQL Global Development Group) Apache HTTP Server (The Apache Software Foundation) PHP Hypertext Preprocessor (The PHP Group) Zend Optimizer (Zend Technologies Ltd.) Microsoft Message Queue (Microsoft Corporation) ipecs-nms Server (LG-Nortel) Software components listed above should be installed in the sequence described in this document. Since there are additional configurations during the installation procedure, the installer should read this section carefully before starting software installation Installing Software Components PostgreSQL Installation After decompressing the PostgreSQL software into a temporary folder, double-click on postgresql-8.2.msi file to start the installation procedure (8.2 is the software version in this manual). Perform the following to Install: On the language selection window, select a language and click [Start >]: 5

11 As recommended in the window, close all the programs running on the NMS server and then click [Next >]. The Installation Notes screen will display. The installation notes describe requirements concerning restrictions on the use of the 64-bit version of Windows and FAT32 file system. Read the notes and verify before starting the installation. After reading the Installation Notes, click [Next >] to proceed. On the Installation Options window, select a folder in which PostgreSQL is to be installed (or just note the default location identified by the program), and click [Next >]. 6

12 PostgreSQL is used as a service, check the Install as a service box and enter all field values (as applicable), then click on the [Next >]. In this document, postgres and postgrespw are used for Account Name and Account Password fields, respectively. Of course, other strings can be used for both fields. If the account name configured in the previous step does not currently exist, the Account Error message may appear asking if the account should be created; click [Yes]. If the password configured in the previous step is not complex enough, a Password notification screen may appear to suggest replacing the password with a more complex one. Click [Yes] to change the password to a more complex one (randomly generated string) for increased password security, or [No] to proceed without changing the password. Within the Initialize Database Cluster screen, make the following entries then click on [Next >]: Select the appropriate language / country for Locale field. Select UTF8 for the Encoding (Server) field. (Keep the default value for Client field. v8.3 Option) Enter the Superuser name and the Password to be used internally by the PostgreSQL database. The Superuser Name and Password field values should be noted because they will be used for ipecs-nms Control program when configuring Database User Information. 7

13 Click [Next >] on the Enable Procedural Languages screen. The default value is selected, however, if there is a reason this value may be changed. The Enable contrib. modules screen lists, routines which contribute to the application (default is recommended). Click [Next >] to continue. When the ready to install screen appears, click [Next >] to begin the installation. 8

14 After the installation is complete, the Installation Complete screen will display; click [Finish]. (Because Stack Builder does not need to be executed, Launch Stack Builder at exit check-box may be unchecked before finishing. v8.3 Option) In order for 3rd-party applications like ipecs NMS to use PostgreSQL, a path to the PostgreSQL binary files folder must be set-up. PostgreSQL does not configure the Path during the installation procedure, so this should be done manually. To set-up the Path, perform the following Steps: Access the Control Panel>System Properties, and click on the Advanced tab. Click on the Environment Variables button at the bottom of the screen. 9

15 In the System variables pane, select the Path variable item, and then click [Edit]. On the Edit System Variable screen, check if the bin directory of PostgreSQL already exists in the Variable value field. If it does not exist, append the directory name of the bin folder at the end of the path variable, and then click [OK]. NOTE When entering the path to the PostgreSQL bin folder, type a semicolon (;) at the end of the variable, and then the directory name of bin folder. In this example, the ;D:\Program Files\Postgres\PostgreSQL\8.2\bin string was appended at the end of the Path variable. The modified Path variable is applied after restarting Windows. However, since the new Path is not required until the ipecs NMS Control program is executed, continue the installation without restarting Windows at this time Apache HTTP Server Installation To install the Apache HTTP Server, perform the following: Double-click on the apache_2.2.8-win32-x86-no_ssl.msi file (2.2.8 is the software version used in this manual). 10

16 Click [Next >] button to proceed with the installation. Read the Apache License notes within the License Agreement screen; click [I accept the terms in the license agreement] to accept the terms and then click [Next >] button to proceed. A Read This First screen will display. Once you have read the screen, click [Next >]. In the Server Information screen, fill in the blanks for Network Domain, Server Name, and Administrator s Address fields: -- Administrator s Address field must be entered. -- If HTTP port 80 (the normal HTTP server port) is to be used, select [for All Users, on Port 80, as a Service Recommended]. When finished, click [Next >] to proceed. 11

17 Select the type of installation; if customized installation is not needed, select [Typical] and click [Next >]. On the Destination Folder screen, note the default location for the Apache HTTP Server files, OR Click on the Change button to select a folder where the files should be installed. Click [Next >] to continue. Click [Install] on the Ready to Install the Program window to start installation. 12

18 When done, the Installation Wizard Completed screen will appear; click [Finish] Apache HTTP Server Configuration As the last Installation step, you may wish to modify the Server Side Includes (SSI) related configuration for better security of the Server and AcceptEx related configuration for more stable communication with Apache HTTP Server. SSI exists in HTML files and makes it possible to provide dynamic Web pages. However, because it can be used to execute CGI scripts or shell commands in the Web server, the server may be vulnerable to security attacks. The use of AcceptEx may cause a communication slow-down problem in some cases, and so it is desirable to disable the use of AcceptEx in Apache HTTP Server. In order to remedy these situations, the Apache HTTP Server (httpd.conf) configuration file should be modified: From the Windows Start menu, select Apache HTTP Server 2.2 > Configure Apache Server > Edit the Apache httpd.conf Configuration File; Or, open Program Files\Apache Software Foundation\Apache2.2\conf\httpd.conf using Notepad or another text editor program). Find the Options Indexes FollowSymLinks option string in the opened configuration file (httpd.conf), and comment (disable) it by typing the pound sign (#) before the beginning of the string as shown in the screen capture (shown). Then, type Options IncludesNoExec on the next line; Win32DisableAcceptEx can be inserted after the </Directory> line as in the example below, or appended at the end of the file. 13

19 Apache HTTP Server writes the access log into the access.log file, and the size of the file grows relatively faster depending on the number of access lines to the server. Therefore, as an option, in order to prevent unwanted waste of HDD space by disabling writes to the access log, find CustomLog logs/access.log common string in the configuration file (shown) and disable it by typing pound sign ( # ) before the beginning of the string. When finished, save the configuration file and then close the text editor program. The modified configuration will be applied after restarting Windows or Apache HTTP Server 2.2. However, since the new configuration is not required until the ipecs NMS Control program is executed, continue the installation without restarting Windows at this time.. 14

20 PHP Hypertext Preprocessor Installation To install the PHP Hypertext Preprocessor, perform the following Steps: Double-click on the php win32-installer.msi file to start the PHP Hypertext Preprocessor installation procedure (5.2.5 is the software version used in this manual). On the Welcome to the PHP Setup Wizard screen, click [Next] to proceed. First read the PHP License within the End-User License Agreement screen; click [I accept the terms in the License Agreement] to Accept the terms and then click [Next >] to proceed. 15

21 On the Destination Folder screen, note the default location for the PHP Hypertext Preprocessor, OR Click Change and enter the folder location where the files should be installed. Click [Next >] to continue. On the Web Server Setup screen, select the web server that was installed (Apache version was installed, so the Apache 2.2.x Module is selected on the screen shot shown). Then click on the [Next] button to proceed. Within the Apache Configuration Directory screen, select the configuration (conf) folder in the Apache HTTP Server installation directory, and then click [Next]. In this document, D:\Program Files\Apache Software Foundation\Apache2.2\conf\ directory is selected. 16

22 On the Choose Items to Install screen, click on the expansion box to the left of the [Extensions] node to view the sub-tree. Find the PostgreSQL node on the subtree, and then click down arrow to show pop-up menu. Select Will be installed on local hard drive, and then click [Next]. On the Ready to Install PHP screen, click [Install] to start installation. 17

23 After the installation is completed, click [Finish] to complete installation process. As the last step, in order to prevent possible file transfer failure cause by restrictive maximum file size and execution time limits from default PHP configuration, those settings in the PHP configuration file ( php.ini ) should be modified. From the Windows Start menu, select PHP 5>php.ini to open the PHP configuration file, Or open Program Files\PHP\php.ini using the Notepad or another text editor program.) Find the post_max_size configuration line, and change the configuration value from 8M to 40M. Find the upload_max_filesize configuration line, and change its value from 2M to 40M. 18

24 Find the configuration line of max_execution_time, and change its value from 30 to 90. After finishing the modification, save the configuration file and then close the text editor program Zend Optimizer Installation To install the Zend Optimizer, perform the following Steps: Double-click on ZendOptimizer Windows-i386.exe file (3.3.3 is the software version used in this document). On Welcome to the InstallShield Wizard window, click [Next >] button to proceed. First read Zend Optimizer License Agreement notes. If you agree to the terms and conditions, select I accept the terms of the license agreement and click the [Next >] button. 19

25 On Choose Destination Folder window, select a folder in which Zend Optimizer is to be installed, Or note the default location for installation, then click the [Next] button. Then, on the Choose Web server window, select the web server installed in the previous procedure, and then click the [Next >] button to proceed. Since Apache version was installed, [Apache 2.x] is selected. On Choose the php.ini folder window, the directory of PHP Hypertext Preprocessor software is configured. The php.ini file is saved in the Program Files\PHP directory. After selecting (or noting the default) directory, click the [Next >] button. 20

26 On Choose the Web server root folder window, the Apache HTTP Server installation folder is configured. In this document, the D:\Program Files\Apache Software Foundation\Apache2.2 directory is selected. The Pre-Install Summary window shows the settings that were configured in the previous steps. After checking all the configurations, click on the [Install] button to complete the installation of Zend Optimizer Web Server Restart Following installation, the Web Server Restart window will appear. Before clicking on the [Yes (Y)] button, you must stop the Apache HTTP Server execution by selecting Apache HTTP Server 2.2>Control Apache Server>Stop from the Windows Start menu. Then click on the [Yes (Y)] button. 21

27 After the installation is complete, start the Apache HTTP Server again by selecting Apache HTTP Server 2.2 >Control Apache Server>Start from the Windows Start menu. When the InstallShield Wizard Complete window appears, click [Finish] button Microsoft Message Queue (MSMQ) Installation ipecs NMS utilizes Microsoft Message Queue (MSMQ) one of the software components provided with Microsoft Windows. In many cases, MSMQ is not installed when the Windows OS is installed; verify if it has been installed. In order for the MSMQ to be properly installed, the server should have a Computer Name previously configured. Check this by viewing System Properties in the Control Panel. For Windows XP To verify MSMQ installation, from the Control Panel, select Add or Remove Programs. Click Add/Remove Windows Components. 22

28 In the Windows Components screen, locate the Message Queuing item and verify if it is installed. If it has not been installed (box is not checked), click the checkbox, and then click [Details ]. Message Queuing includes Active Directory Integration. If a domain controller or controller server that provides directory service does not exist, clear the Active Directory Integration checkbox, and click [OK]. After returning to the Windows Components screen, click the [Next >] to start installation. After installation is completed, click [Finish]. 23

29 For Windows 2003 Server From the Control Panel, select Add or Remove Programs. Click on Add/Remove Windows Components. In the Windows Components screen, click on Application Server and click [Details ]. In the Application Server screen, locate the Message Queuing item and verify it is installed. If it is not installed (box is not checked), click on checkbox, and then click [Details ]. 24

30 Message Queuing includes Active Directory integration. If a domain controller or controller server that provides directory service does not exist, clear the Active Directory Integration checkbox, and click [OK]. After returning to the Windows Components screen, click [Next >] to start installation. After the installation is completed, click [Finish] to complete the installation procedure ipecs NMS Software Installation To install the ipecs NMS Software, perform the following Steps: Click ipecs_nms_setup.exe file to start installation; the InstallShield Wizard screen should display. Click [Next >] to proceed. NOTE If required software components have not been properly installed or ipecs-nms Service is installed and running, a warning message may appear. In this case, verify installation of required software or terminate the ipecs-nms Service, and then restart the installation procedure. 25

31 In the Customer Information window, enter the User Name and Company Name fields, and click [Next]. Normally the default destination location for program files need not be modified, click [Next>] to continue. If a different destination is desired, click [Change] and select the new location, and then click [Next >]. On the Select Web service root directory screen, select the htdocs folder under the Apache HTTP Server installation directory, D:\Program Files\Apache Software Foundation\Apache2.2\htdocs was used in this example. After the folder is chosen, click [Next >] to proceed. NOTE if the location for the Apache server files was changed, that directory should be selected by clicking [Change ]. 26

32 Click [Install] to begin software installation. After the installation is completed, click [Finish]. To apply changed configurations, restart your computer Executing ipecs-nms Application The ipecs-nms application is comprised of two programs: ipecs-nms Control (ipecs_nms_control.exe) ipecs-nms Service (ipecs_nms_service.exe) ipecs NMS Service is the main program, which runs as a Windows Service application. ipecs-nms Control registers ipecs-nms Service to the Windows Service list and manages the NMS Service operation and database. 27

33 For registration and execution of ipecs-nms Service, perform the following Steps: In the ipecs-nms installation folder (Program Files\LG-Nortel\iPECS NMS), locate the ipecs_nms_control.exe file and double-click to execute it. (Or, from the Windows Start menu, select LG-Nortel > ipecs NMS > Launch ipecs_nms_control.exe to execute it.) Within the NMS Control screen, enter the User and Password fields using the Superuser Name and Password configured during the installation of the PostgreSQL software. The values postgres and postgrespw were used in this example. Click [Update] when finished making entries. After the two fields are configured, Create Database activates. The NMS local database should be created before registering and executing ipecs-nms Service. Click the [Create Database] button. 28

34 NOTE If a local database already exists, the [Delete Database] is present instead of the [Create Database] button. [Delete Database] should be used with caution; when selected, all information stored in the database is permanently removed. The NMS Client Character Set field normally need not be changed from the default value provided by ipecs-nms Control. However, in some cases the character set used in the NMS server might not be supported by the PostgreSQL database. If this problem should occur, an error message may appear. Select an appropriate Character set from the drop-down list, as needed. If a local database was successfully created, the [Load Service] button will activate; click [Load Service] to register the ipecs-nms Service to the Windows Service list. After the ipecs-nms Service registers, the [Load Service] button will deactivate, and the [Unload Service] and [Start Service] buttons will activate. Click [Start Service] to execute the ipecs-nms Service program as a Windows Service. When running, the [Start Service] button will deactivate and the [Pause] and [Stop Service] buttons will activate. Neither [Stop Service] nor [Pause] should be required for normal operation: [Stop Service] terminates ipecs NMS. [Pause] temporarily suspends execution of the ipecs-nms Service program. Click [Close] to exit the ipecs-nms Control program; the control program does not need to be running while the ipecs-nms Service is in use. 29

35 2.3 ipecs System Admin Configuration Before registering ipecs systems to the ipecs-nms, NMS-related system admin fields should be configured. After logging-in to ipecs Web Admin, click SNMP Attribute (P196) from the System Data list to enter the NMS configuration page. The SNMP Attribute (P196) screen is categorized into three parts: SNMP Agent SNMP Service field is used for enabling or disabling (ON or OFF) the SNMP agent service running on MFIM; this field should be set to ON for communication with ipecs-nms using SNMP protocol. - SNMP Port - Standard SNMP port number 161 should be used unless there is a specific reason for changing this port number. SNMP Security SNMP community and NMS server IP address can be configured; the SNMP community designates a SNMP communication group to which an SNMP message belongs, and is also a logical relationship between the SNMP agent (MFIM) and SNMP manager (NMS). - Read Only Community defines a community string that should be used when SNMP manager (NMS) is trying to read data from the SNMP agent (MFIM), and its default value is set to public - Read Write Community is used for both read and write data by the SNMP manager (NMS), and its default value is private. This value should be the same as set up on the ipecs-nms community string (default=private, but could be changed following 30

36 installation as needed) - Accept SNMP Packet from Any NMS Server if IP Address is not fixed, click to accept SNMP packets from any SNMP manager (or from any IP address), OR - Accept SNMP Packets from These NMS Servers if IP Address is fixed, click to designate IP addresses to be allowed and the method of data transaction (Read Only / Read Write). SNMP Trap configuration is for setting the destination IP address to which Trap messages (ex., alarm/fault events) are to be sent from the SNMP agent (MFIM). Trap Community designates a Trap communication group to which a Trap message belongs, and is also a logical relationship between the SNMP agent (MFIM), and SNMP manager (NMS). This value should be same as the Trap community string defined in ipecs-nms in order for the Trap messages sent from SNMP agent to be accepted by the ipecs-nms server. NOTE Trap communities should be set-up same for all the ipecs systems registered to an ipecs-nms server (default=public, but could be changed following installation as needed), whereas the SNMP community may be defined with different strings for each ipecs system. - Trap Destination is for designating the IP address of the ipecs-nms server, the Trap port number (default=162), and the Trap type field (Notification, Inform, and Trap). Notification defined in SNMPv2c that is sent once without checking the reception of the message. Inform - similar to Notification, but checks the reception of the message using a Response message sent from the receiving SNMP manager (NMS); messages not transmitting a response will be assumed lost and will be sent again (ex., used in an unstable network where there is packet loss, but may decrease network performance when too many messages are present in the MFIM. Trap defined in SNMPv1, but because ipecs-nms and the SNMP agent on MFIM use SNMPv2c, it is not recommended. After finishing all configurations, click on the [Save] button to save and apply the field values. 31

37 3. Getting Started 3.1 Overview of Set-up Once the NMS Server is installed and running, it will monitor registered ipecs systems and be available to service NMS clients, and Web browsers. After initial installation, check the Windows Service status (Section 3.2), and configuration of the following: NMS Management Functions (Section 4.1, NMS Server Management) NMS Users and Authority (Section 4.2, User Accounts Management) Register ipecs Systems for services (Section 4.3, System Management) 3.2 Checking Windows Service Status In order for ipecs-nms to execute properly, verify that Apache HTTP Server, PostgreSQL Database Server, and ipecs-nms are all running as Windows Services. These Windows services may start automatically when the server is restarted, or may be manually controlled using the Windows Administrative Tools for Services: From the Windows Control Panel, double-click on Administrative Tools. Next double-click on Services in the list of available tools. Within the Services window, check or modify the status of services (ex., in this image, the Apache 2.2 service is in Started status, and Startup Type is Automatic ). Using the Properties of a specific Service (right-click on a Service), the Startup Type can be adjusted from Manual to Auto (shown). 32

38 NOTE The status of the ipecs NMS service also can be checked and changed using the ipecs- NMS Control program (refer to ipecs-nms Software Package Installation). 3.3 Accessing the ipecs NMS Server Using a Web Browser ipecs NMS is a Web based application using a Web Browser as the NMS client. Opening your browser and pointing it to the ipecs NMS server automatically opens the NMS client. For optimum performance, use a broadband connection and set the Tools>Internet Options>Temporary Internet Files>Settings or >Browsing History>Settings (depending on your browser version) to Check for newer versions of stored pages, select Automatically. To login to the ipecs-nms, execute the Web browser on the client PC and enter the IP address of the NMS server. 33

39 On the ipecs-nms login page, enter the Admin User ID and Password (ex., Admin and default password ipecsnms were used in this document). Then click on the [Login] button. NOTE The admin account is the ipecs-nms Superuser account and cannot be deleted, but the password can be changed. After logging into the NMS server, the ipecs-nms main page will display. Below, each component of the page is identified followed by a brief description: (3) (4) (1) (5) (2) 34

40 (1) ipecs System Explorer Lists registered systems with Station, CO, and other devices shown in a tree format. If system groups are created to manage systems (refer to Section 4.4.2), those groups are also displayed in tree format. (2) Alarm/Fault Summary For alarm/fault events shows the number of events not yet checked by the administrator. For quick access to events, clicking on [Go to Alarm/Fault Management] moves to the Alarm/Fault management screen. When an alarm/fault event occurs that is configured to play audible alarm in Alarm/Fault Config, an alarm sound is played depending on the setting of Audible Alarm (Toggle=One Time, Repeat, or Disabled). When set to Repeat, alarm can be stopped by clicking [Alarm/Fault Summary] or [Go to Alarm/Fault], or clicking the [Alarm/Fault Analysis] menu tab (Toggle=color change from orange when a new alarm/fault occurs). (3) Information and Control bar - Displays the selected ipecs System Name (on left) and, the NMS User ID and two indicator blocks (on right): - Block #1(left) The left block indicates status of NMS client running on Web browser (blinks at a 5 second interval). - Block #2 The right block indicates communication status between NMS client and server (blinks at a 10 second interval). In the small space to the right of block 2, an animating indicator shows when the NMS client is retrieving data from the MFIM. (4) NMS Menu - Provides tabs to access NMS Web pages for ipecs system related information and the System, User and NMS configuration pages; clicking on a tab moves to the corresponding functional page. (5) Displays functional pages corresponding to each menu Some pages may have a 2 nd -level menu depending on the number of features they provide. To log out from ipecs-nms: Click on the [Log-out] button at the top-right of the screen. If a client web browser is closed without logging-out from the ipecs-nms (by clicking on the [Log-out] button), the client status will be cleared after about 1 minute, automatically logging out the User. The ipecs-nms provides various kinds of information in table format. Most of the tables accept those with row naming (ex., System Information, Additional System Information, Channel 35

41 Information, Device Information, and Device Network Information), support table sort by column order. Click a column header, and the table is arranged in the ascending or descending order of the column. Selection of ascending or descending order toggles each time the column header is clicked. 3.4 NMS Message Exchange Overview ipecs-nms exchanges various types of information with the registered ipecs systems using SNMP/Trap messages. The message types and the information exchanged under each operational situation are as described in the following table: Operational Situation Message Type Message Information ipecs-nms Restart System Restart System Registration ipecs-nms Service is Operating Client is Logged in & Operating (Retrieved by User System Configuration Device Configuration Basic Channel Information Alarm/Fault/System Event (Trap) KeepAlive Message (Trap) Network Traffic Information (if initiated by NMS user) ipecs Firmware File (if initiated by NMS user) Detailed Channel Information Device/Channel Status Information IP Address, Site Name, Firmware Version, Nation Code, etc. IP address, Device Type, Firmware Version, Location Mode, etc. Device Number, Physical Number, Logical Number, etc. Refer to Alarm/Fault/System Event Table. Periodically Sent from MFIM. Ping, Traceroute, Device Traffic, ipecs Ping, ipecs Traffic. ipecs Device/MFIM Firmware File for Firmware Upgrade. CO Name, CO Type, CO Group, Station Name, Station Type, etc. Device Status, Channel Status Information. Operation) Call Statistics Information Traffic Analysis, DECT Statistics Information. 36

42 4. NMS Management 4.1 Modify Superuser Configuration It is recommended to change the information of the Superuser (Admin) account when the Superuser logs in for the first time. To change a User account, refer to User Account Configuration. To change the information of the Superuser: From the NMS Menu, click on the [User] tab and then [User Config] sub-menu. If you click the admin item from the List of All Users then the User information of admin will be displayed. The initial password for admin should be changed for the security of your ipecs-nms. when finished making changes, click on the [Modify] button to apply the information to the Superuser account. To confirm the modification, log out ipecs-nms (by clicking the [Log Out] button) and log-in again with the new password. 4.2 NMS Server Management The NMS Management screen is used to establish common ipecs NMS characteristics, including: NMS Mail Server Trap Community KeepAlive Timer External Web Link. Each of these is discussed in the following paragraphs. To access the NMS Management page: 37

43 After logging-in to the ipecs NMS, click the [NMS] tab in the NMS Menu (shown) NMS Mail Server Configuration If an alarm or fault event occurs, ipecs NMS server will attempt to send an to User accounts assigned to receive notification. In order to send an , NMS server must have an account on a Simple Mail Transfer Protocol (SMTP) server. While an existing account could be used, it is recommended a separate ipecs NMS account be created in the e- mail server. To set-up service in ipecs NMS: From the the NMS Mail Server (SMTP) Configuration area of the screen, enter the name or IP address of the server, domain name, SMTP port, account name and password. 38

44 SMTP Server/Port if it is not clear what information to input, contact your System Administrator for help. Domain Name is the domain name part of an address managed on the SMTP server (normally the part of an address following symbol). Click [Save] to store the NMS account information. After completing NMS mail server (SMTP) configuration, [ Send Test] button can be used to check if is sent properly using the configuration. The is sent to the address of currently logged-in user (verify the address of the user is configured in User Config of User menu before clicking the [ Send Test] button) Trap Community Configuration The Trap Community is a string that represents the group of SNMP Trap communication. It is used for sending alarm/fault event messages between the NMS and the ipecs System. The same Trap Community string must be set in both the ipecs Web Admin. and NMS. On ipecs Web Admin., the trap community can be set in the SNMP Attribute (PGM196) configuration. To change the trap community, enter a 4 to 16 character string (default=public) in the Community box and click [Save]. Verify that registered ipecs systems are also updated with the same information System KeepAlive Interval Configuration The ipecs system periodically sends KeepAlive messages to the ipecs NMS for updating the operation and communication status. If the system fails to send a KeepAlive message or it is not received by ipecs NMS for more than 5 minutes, the system is considered off-line. To control traffic, the polling interval can be changed. To change the interval value: Enter a value ( sec.) in the box and click [Save] External Link Configuration The External Link button on the Information and Control bar accesses a defined Web page (URL). 39

45 To set-up the External Link control: Enter the desired URL for the External Link button to connect to, and click [Save]. To confirm the desired configuration, click the [Ext Link] button; the new web browser window will be opened and the designated External Link URL web page will be displayed. NOTE Depending on the configuration of your web browser, some problems may occur on opening the new browser window (ex., security level, or blocked link). In this case, you should allow opening new browser window for the specific URL. 4.3 User Management User Management provides the means to manage user accounts and assign users to each system to implement management domain for each user. Access control function provides the information of the users currently logged-in to ipecs-nms, and allows making a selected user to be logged out of ipecs-nms if needed. The pages for these features can be entered by clicking [User] tab on the top level menu User Configuration User Accounts are managed under the [User Config] menu. Accounts can be added, modified and deleted, as well as specific ipecs systems may be assigned to an account. Up to a maximum of 100 accounts can be created, and 10 users including admin, may access the server simultaneously. It is also possible to assign specific users to each system so that only assigned users can operate on the system. To access the User configuration screen, click [User Config] under the User menu. 40

46 The User configuration screen includes a List of All Users, User information and ipecs system assignment windows. The User information window manages User Accounts and specific ipecs systems are assigned to a User account in the System Assignment to window User Account Configuration Each User account has an associated unique User ID (4-16 characters) and password. Each account has an assigned Privilege. User Account levels (Privileges) available are: Administration - allows full access to ipecs NMS server; note the admin account is the super-user account with access to all functions of NMS and information on all systems registered to NMS. This account cannot be deleted, but the password can be changed. If this is a first time installation, for security purposes, it is recommended the admin user account password be changed from the default. Operation - allows access to all of the NMS services except for User, NMS or System configurations screens at the Top-level menu. Monitoring - allows access to the System Info, Status and Alarm/Fault screens from the Top-level menu. Additionally, the language preference and address (up to 40 characters) can be entered. Language selection only applies to messages from the ipecs NMS server and not from other services or Windows. To receive notification, notification must be assigned in the System Configuration screen (refer to Section 4.4.1). To add a new account, enter the desired User ID to create in the User Information window and click [Add]. To modify or delete an account, select the desired account in the List of All Users, change the necessary User Information and click [Modify], or click [Delete] to erase the account. NOTE Once a User ID is created, it cannot be changed. 41

47 The [Clear Field] button is used to empty all field values in the User Information except Privilege and Language System Assignment to User Account The System Assignment window displays the assignments for the ipecs system or group of systems selected in the System Explorer (left frame). The display shows the selected group name, system name and authorized user accounts. Each User account is assigned management and monitoring authority for each registered ipecs system. An account can access only information for authorized systems and a system can have up to five managing User accounts including the admin account which can not be modified. To assign a system to a user account, select the desired system or group from System Explorer, then select the account in List of All Users. The System assignment to window displays the account s authority for the system(s). To change the System Assignment: Click the [Assign] box in the list header to check or uncheck all the boxes in the list, or individually click to check the Yes or No box of each item as desired (toggle). Selected users will be shown in the User list. After finishing assignment, click on [Save Changes]. To confirm assignment changes, logout and login with the target User ID. After login, Systems assigned will be shown. 42

48 4.3.2 Set Notification to User Account If a system is assigned to a user account, the user can receive alarm/fault notification via . notification is designated in the System Config menu. To access System Config : Click on [System] from the main menu. The user accounts, which are assigned as manager, will be displayed in User Notification when a system is selected in the system list. Check user accounts who want to receive notification and click [Modify] button to save. If an alarm/fault event in the system occurs, the ipecs-nms will to the selected user addresses already saved in user configuration. NOTE--In order for an to be sent properly, the Mail (SMTP) Server and the address of the assigned user should be configured as well User Access Control User Access Control provides functions for retrieving the information of currently logged-in users and their log-in times. And if necessary, specific users can be forced to be logged out of ipecs-nms by the administrator. The page for this feature can be entered by clicking on the [Access Control] tab menu. 43

49 After User Access Control page is opened, currently logged-in users are listed in the log-in user table. In this table, the information configured in User Configuration for each user and their login times are displayed. The log-in user table updates log-in user information every 10 seconds. In order to refresh the log-in user information instantly, click [Refresh Log-in User Information] button. If it is needed to force a specific user to be logged out of ipecs-nms for some operational reason, select the user on the log-in user table and click [Force Log-out] button. Then, an NMS warning message is displayed on the user s NMS client screen, and after [OK] button is clicked, the NMS client becomes logged out of ipecs-nms automatically. 4.4 System Management System Management provides functions for ipecs system registration and system group management. Up to 500 ipecs systems and 100 system groups can be configured, and the system groups can be configured to have up to 4 sub-level groups under the top most Groups node. System Web Admin can be accessed directly from ipecs-nms, and functions for device firmware upgrade and upload/download of system database, system greeting & prompt are also provided. The System Management screen of the NMS Menu bar includes: System Config - used to manage registration of ipecs systems, Group Config - used to organize registered systems into easier to manage groups Web Admin Config - used to manage and access the Web Admin and Maintenance of registered systems, Firmware Upgrade - used to upgrade the firmware of MFIM or other ipecs devices. 44

50 To enter the System management menu, click on the [System] tab on the NMS Menu System Configuration Registration of ipecs systems to ipecs-nms is managed in the System Config page. Systems can be added or deleted, and information on a registered system modified. For each system, alarm/fault notification is assigned to User accounts. The User account must be assigned to manage the specific system and receive notifications (refer to Section 4.3). Information required for each registered system includes a unique system name (4-16 characters, with no special characters), System IP address, SNMP Port number (default=161, but may be changed), Community (4-16 characters, not special characters) and a Description field (63 characters). The Community field is a 4 to 16 character value (no special characters) that defines the SNMP Read-Write community between the system and NMS, and must match the Read-Write Community SNMP Attribute (PGM 196), designated in the ipecs system database. This string is used for sending read-write messages between the system and NMS. The lower portion of the screen displays the System Status chart which includes a list of all registered systems, status, SNMP community, etc for each system. Prior to adding a system registration with ipecs NMS, the system should be enabled for monitoring and management by NMS, refer to Appendix 1 for details on ipecs system set-up. 45

51 To add an ipecs system registration: Select the [System Config] tab, and enter the information in the System Information area. Check boxes next to the User account name to enable notification and then select [Add]. The system is initially added to the System status chart with a disconnected status. NMS will contacts the system for information exchange. If the connection is successful, the status will change to Connected and NMS will receive basic information from the added system and save it to a local database. If the System remains disconnected, verify the connection between ipecs NMS and the ipecs system then click [System DB Refresh] to update the NMS database. To modify or delete a system: Select the System from the System status chart, and change the information. The System name cannot be changed. User Notification is for designating where to send alarm/fault notifications related to the system; only system Administrators can be set as notification receivers (refer to User Configuration). Select [Modify] to accept changes, or [Delete] to remove the registered system. The [Clear Field] button is used to empty all fields (except SNMP Port and Community). The system data currently listed on the system table can be downloaded and saved as Excel format file by clicking on the [Excel Report] button. The picture above shows an example of a downloaded Excel report file System Group Configuration The Group Config page is used to organize the registered systems into groups for easier management. Systems are displayed in System Explorer (left frame) in a menu tree using this 46

52 grouping. Up to 100 groups may be defined in a tree with up to 4 branches. The Group Config page shows the List of Group Member Systems and the System Groups & Member Systems charts. To add a group: Select [Group Config] in the System Group & Member Systems chart, and click on the next higher level group name. Ex., To enter a group under the top-level of the group tree, select Groups. Enter a unique group name (4 to 16 characters, no special characters) in the text box and click [Add]. NOTE Once a group name is created/added, it cannot be changed. To delete a group, highlight the group name and click on [Delete]. To add new systems to the top-level group, in the System Explorer select Groups ; all the current systems in the group are displayed. In the System Group & Member Systems field, fill in the new group name in the Group Name text box (4-16 characters with no special characters), and click on the Add button to create the group. Then, from the the List of Group Member Systems, select each system to be placed in the group by clicking the associated check box. Click the arrow between to the two charts to move the systems to the new group. To remove a system group, select the group in the System Group & Member Systems chart, and select [Delete]. 47

53 4.4.3 Web Admin Configuration The Web-Admin Config page is used to manage the ipecs system Web Admin passwords and to access the ipecs System Web Admin without the need to manually enter the password. When accessing Web Admin from ipecs NMS, NMS supplies the password to the system automatically. To access Web-Admin Config page: From the System main menu, click the on the [Web-Admin Config] tab. To set-up a password, select a system from the list (lower portion of the page), and enter the Web Admin password assigned in the ipecs system database. Select [Set Password]. Use [Delete Password] to erase a password Web Admin Access The Web Admin and Maintenance functions of a registered system can be accessed directly from the ipecs NMS for managing the ipecs system. To access the Web Admin of a system: Select [Web-Admin Config] from the System management menu, and select the system from the system list and then click [Start Web Admin]. This will open the initial Web Admin page of the selected system; refer to the figure below and the ipecs Admin and Maintenance Manual for more details. 48

54 4.4.5 Firmware Upgrade Firmware Upgrade is used to upgrade firmware for a specific type of ipecs devices of selected systems at a designated time. To perform a Firmware upgrade: From the System Management menu, click on the [Firmware Upgrade] tab. Click on the [Browse ] button to select a firmware file to use for upgrading device firmware, then the file name will be displayed in the Firmware File field and Module Type field will 49

55 display the type of the device that can be upgraded using the selected firmware file. When the [Get System Info] button is clicked, the systems to which the upgradable devices are registered will be listed in the System List table. The upgradable modules that are registered to a specific system will be listed in Target Modules when clicking on the system item in the System List. NOTE--Target Modules does not display MFIM item when upgrading the firmware of MFIM. System List and Target Modules tables display detailed information of the systems and target devices on the table fields. The types and meanings of the table fields are as listed in the following table. Table Name Field Name Description System List System Name IP Address Firmware Version Status No. of Modules The name of the system configured when registering to ipecs NMS. The IP address of MFIM that is the main call processing module of ipecs system. The firmware version of MFIM. The connection (communication) status between ipecs-nms and ipecs system (MFIM). The number of devices that can be upgraded with the selected firmware file. 50

56 Table Name Field Name Description Upgrade Status shows the process status of firmware upgrade of the system, and includes the status values of Connecting FTP, Transferring by FTP, Transferring by HTTP, Upgrade MFIM, Upgrading Device, Finished, and Failed. In normal cases, the status will display Connecting FTP when the firmware upgrade is started, and the FTP connection is made between Upgrade Status NMS server and MFIM. After the FTP connection is established, the status changes to Transferring by FTP and the firmware file is transferred from NMS server to MFIM. After the file transfer is completed, the status becomes Upgrading MFIM or Upgrading Device and performs the firmware upgrade for MFIM or target devices. When firmware upgrade is finished, the displays as Finished status. NOTE- Transferring by HTTP status may be shown when firmware upgrade is being performed by Web Admin. Upgrade Time Dev. No. Device Type IP Address Firmware Version When the firmware upgrade for the system is finished. (Device Number) is the device sequence number of the device on ipecs Web Admin.; a unique number is assigned to each registered device. The name of the device The IP address of the device The firmware (software) version of the device Location of the device that was configured when the device was Location Mode registered on system (Local, Remote, Local-Remote, and Remote Target Modules Device Status Upgrade Status RSGM). Device Status shows the operation and registration status of the device (Disconnect, Active, T-Net, Downloading, Out-of Service and N/A). Upgrade Status shows the process status of firmware upgrade of the device (Ready, Started, Transferring, Transfer Completed, Success, and Failed. In normal cases, the status of all the target devices will display Ready when the firmware upgrade for the system is started. After the firmware upgrade is started for each device, the firmware file is transferred to the device under Transferring status. After the firmware transfer is completed, the status changes to Transfer Completed, and then becomes Success when the firmware upgrade is finished. 51

57 To select target systems to upgrade, click the check-box of each system. The Estimated Time field will be updated and will show the estimated time for the overall firmware upgrade procedure on all the selected systems. Estimated time is calculated based on the number of systems and target devices, so it may be somewhat different from the actual upgrade time. Because a system can be configured for one firmware upgrade at a time, only the systems that are not already scheduled for other firmware upgrade can be selected in System List. In order to schedule a firmware upgrade at a specific date and time, configure the target date and time for firmware upgrade in Date/Time field, and then click on the [Execute] button. The firmware upgrade will be automatically started at the designated date and time for the selected systems. If the Date/Time field is configured with the current date/time or a past date/time, the firmware upgrade will immediately start after clicking on the [Execute] button. If the [Cancel] button is clicked while the firmware upgrade is in process for multiple systems, the schedules for waiting systems can only be canceled, and the systems that are performing firmware upgrade at the moment proceed the firmware upgrade to the end and finish their upgrade procedure. The Status field shows the overall process status of the firmware upgrade for all the selected systems (Transferring to NMS, Scheduled, Upgrading, and Finished). Transferring to NMS designates the status of the transferring firmware file from the NMS client browser to NMS server; this is performed immediately after clicking on the [Execute] button. After firmware file transfer to NMS server is completed, the Status will change to Scheduled if 52

58 the Date/Time field is configured with future date and time, or will change to Upgrading if the firmware upgrade is started after the current time has exceeded the date and time configured in the Date/Time field. When the firmware upgrade for all selected systems is finished, the Status field will display Finished to show that the overall firmware upgrade procedure is finished System DB Management System DB Management provides the means to upload or download system a DB file to/from the ipecs system, and also periodically backup the system database to the NMS server. The pages for these features can be located by clicking on the [System DB] tab menu under System Management System DB Upload System DB Upload function is for uploading a system DB file stored in the NMS client PC or in the NMS server to selected ipecs systems. The page for this function can be opened by clicking on the [Upload] button on top of the System DB Management screen. In order to upload a system DB file stored in the NMS User PC to the ipecs system, the system DB file should be selected first. Click on the [Browse ] button to select the system DB file, then the selected file name is displayed in the DB File field. The appended string (Local) means that the file is selected from the NMS user s PC. The DB Type field displays the DB type of the selected system DB file. After a system DB file is selected, the check-boxes of the systems that can be uploaded with the 53

59 selected file become enabled, and for other systems that cannot accept the selected file, the check-boxes become disabled. Select the Sel check-boxes of the systems to be uploaded with the selected DB file. If system reset is needed after completing system DB upload, click the Reset check-boxes of those systems as well. After completing the configuration, click on the [Upload] button to start the system DB upload process. After the upload process is initiated, the system DB file is transferred to the NMS server first, and then uploaded to selected systems. As the upload process is proceeding, in the status string of the Status edit-box changes from File transferring to NMS to Uploading, and when the uploads for all the selected systems are completed, it displays Finished. The Upload Status field in system list displays Transferring by FTP (xx%) ( xx is the rate of file transfer process) after file upload for a specific system is started, and then displays Updating when file transfer is finished and the transferred system DB file is being applied to the ipecs system database. After applying the system DB file, the Upload Status changes to Finished. Some types of system DB files such as All Database requires ipecs system reset to complete applying the uploaded DB file. Therefore, in this case, the Reset check-box should be selected 54

60 so that the ipecs system can be automatically restarted after uploading and applying the system DB file. In the case that All Database files are backed-up in NMS server using the Scheduled Backup feature, a system DB backup file can be uploaded to the ipecs system. Before performing this, select a system that has been configured to use Scheduled Backup from the system list to check if the system DB file to be uploaded has been backed-up in the NMS server. When a system DB file is selected for uploading in the System DB in NMS Server, the selected 55

61 file name is displayed in DB File field. The appended string (NMS Server) means that the file is selected from the backup files stored in NMS server. After DB file is selected, select the Sel check-boxes of the systems to be uploaded with the selected DB file. If system reset is needed after completing system DB upload, selected Reset check-boxes of those systems as well. After finishing all the configurations, click on the [Upload] button to start the system DB upload process. Selecting target systems needs to be done carefully especially when uploading All Database file as well as other types of system DB files so that improper or unwanted systems are not to be selected and uploaded by mistake. In order to delete system DB files stored in NMS server, select the Del check-boxes of the files to be deleted in System DB in NMS Server, and then click [Delete] button. In order to download a system DB file stored in NMS server into NMS user s PC, click on the system DB file to be downloaded in System DB in NMS Server, and then click [Download DB File] button System DB Download System DB Download function is for downloading system DB file of selected ipecs system into the NMS client PC. The page for this function can be opened by clicking on the [Download] button on top of the System DB Management screen. 56

62 At first, select the type of system DB to be downloaded using the combo-box in DB Type field (refer to the ipecs System manual for detailed meanings and explanation of each database type). After selecting a system from which the DB file is to be downloaded, click on the [Download] button to start downloading the system DB file from the selected ipecs system to NMS user s PC System DB Scheduled Backup System DB Scheduled Backup function is for automatic downloading of All Database DB files of selected ipecs systems by predefined backup period, and the downloaded backup files are stored in the NMS server. The page for this function can be opened by clicking on the [Scheduled Backup] button on top of the System DB Management screen. 57

63 In the Time field, configure the backup time when All Database file is downloaded to NMS server, and in Period (Day) field, the backup period in days. No. of Backup Files is for setting the maximum number of backup files stored in NMS server per system. After this number of files has been backed-up, the oldest file is deleted when new system DB file is downloaded. Select the check-boxes of the systems from which All Database files are to be backed-up, and then click [Execute] button. Afterwards, All Database files are downloaded from the selected systems and stored in NMS server periodically when the configured period and time has come. The maximum number of backup files per system follows the number in the No. of Backup Files field. After the DB file backup is performed, clicking on a selected system in system list shows the All Database file downloaded to NMS server in System DB in NMS Server. 58

64 In order to delete system DB files stored in NMS server, select the Del check-boxes of the files to be deleted in System DB in NMS Server, and then click on the [Delete] button. In order to download a system DB file stored in NMS server into the NMS user s PC, click on the system DB file to be downloaded in System DB in NMS Server, and then click on the [Download DB File] button Prompt Upload Prompt Upload provides the means to upload entire prompt or individual prompt files to the VSF (Voice Store-and-Forward) of selected system, and can be entered by clicking [Prompt Upload] tab menu under System Management. * This feature applies only to VSF inside ipecs MFIM, and is not applicable to VMIM Entire Prompt Upload Entire Prompt Upload function is for uploading an entire prompt file to the VSF of selected ipecs system. The page for this function can be opened by clicking [Prompt Upload] button on top of Prompt Upload screen. In order to upload an entire prompt file stored in NMS user s PC to the VSF of ipecs system, the prompt file has to be selected first. Select a target prompt file by clicking [Browse ] button, and then the selected file name is displayed in Prompt File field. The name of entire prompt file must have the file extension of rom as in xxxx.rom. 59

65 Select the check-box of the target system to be uploaded with the entire prompt file, and select the position of the prompt in VSF with Position combo-box. After completing the configuration, click [Upload] button to start prompt file upload process. After the upload process is initiated, the prompt file is transferred to NMS server first, and then uploaded to selected systems. As the upload process is proceeding, the status string in Status edit-box changes from File transferring to NMS to Uploading, and when the uploads for all the selected systems are completed, it displays Finished. The Upload Status field in system list displays Transferring by FTP (xx%) ( xx is the rate of file transfer process) after file upload for a specific system is started, and then displays Updating when file transfer is finished and the transferred prompt file is being applied to VSF. After finishing applying the prompt file, the Upload Status changes to Finished Individual Prompt Upload Individual Prompt Upload function is for uploading an individual prompt file to the VSF of the selected ipecs system. The page for this function can be opened by clicking on the [Individual Upload] button on the Prompt Upload screen. 60

66 In order to upload an individual prompt file stored in the NMS user s PC to the VSF of the ipecs system, the prompt file has to be selected first. Select a target prompt file by clicking on the [Browse ] button; the selected file name is displayed in Prompt File field. The individual prompt file must have the wav file extension (ex., xxx.wav). Here, xxx is the prompt number of the file, and can have the value of 1 ~255. In addition to the wav file format, the file should be encoded with G.711 µ-law (or CCITT µ-law) at 8kHz sampling rate. Select the check-box of the target system where the individual prompt file will be uploaded, and select the position of the prompt in VSF with the Position combo-box. After completing the configuration, click on the [Upload] button to start the prompt file upload process. The Status and Upload Status fields of the system list will update as the file upload progresses, until Finished appears in the Upload Status field System Greeting Management System Greeting Management provides the means to upload/download all or individual system greeting files to/from the VSF (Voice Store-and-Forward) of selected system, and can be entered by clicking on the [System Greeting] tab menu under System Management. NOTE This feature applies only to VSF inside ipecs MFIM, and is not applicable to VMIM Entire System Greeting Management Entire System Greeting Management function is for uploading/downloading entire system greeting file to/from the VSF of selected ipecs system. The page for this function can be 61

67 opened by clicking on the [System Greeting] button (shown below). In order to upload an entire system greeting file stored in NMS user s PC to the VSF of the ipecs system, the system greeting file has to be selected first. Select a target system greeting file by clicking on the [Browse ] button, and then the selected file name is displayed in the System Greeting File field. The system greeting file must have the rom file extension (ex., SGTYPEx.rom ). Here, x is the position of the system greeting in VSF, and can have the value of 1~3. However, this position value does not have meaning when executing the upload process. Select the check-box of the target system to be uploaded with the entire system greeting file, and select the position of the system greeting in VSF using the Position combo-box. After completing the configuration, click on the [Upload] button to start the system greeting upload process. After the upload process is initiated, the system greeting file is transferred to the NMS server first, and then uploaded to selected systems. As the upload process is proceeding, the status string in the Status edit-box changes from File transferring to NMS to Uploading, and when the uploads for all the selected systems are completed, it displays Finished. The Upload Status field in the system list displays Transferring by FTP (xx%) ( xx is the rate of file transfer 62

68 process) after file upload for a specific system is started. The System will display Updating when file transfer is finished and the transferred system greeting file is being applied to VSF. After finishing applying the system greeting file, the Upload Status changes to Finished. The entire system greeting file stored in VSF can be downloaded to the NMS user s PC using System Greeting Download under system list. In system list, click on the system from which entire system greeting file is to be downloaded, and then entire system greeting files of each position are displayed in System Greeting Download. The target entire system greeting file can be downloaded to NMS user s PC by clicking on the system greeting file in System Greeting Download Individual System Greeting Management Individual System Greeting Management function is for uploading/downloading individual system greeting files to/from the VSF of a selected ipecs system. The page for this function can be opened by clicking [Individual Greeting] button. 63

69 In order to upload an individual system greeting file stored in the NMS user s PC to the VSF of the ipecs system, the system greeting file has to be selected first. Select a target system greeting file by clicking on the [Browse ] button, and then the selected file name is displayed in the System Greeting File field. The name of individual system greeting file must have the wav file extension (Ex., yy.rom or x_yy.wav). Here, x is the position of the system greeting in VSF, and can have the value of 1~3. However, this position value does not have meaning when executing the upload process. yy is the individual system greeting number, and can have the value of 1~72. In addition, the file should be encoded with G.711 µ-law (or CCITT µ-law) at 8kHz sampling rate. Click-on the check-box of the target system to be uploaded with the individual system greeting file, and select the position of the system greeting in VSF using the Position combo-box. After completing the configuration, click on the [Upload] button to start the system greeting upload process. The Status and Upload Status fields of the system list will update as the file upload progresses, until Finished appears in the Upload Status field. 64

70 The individual system greeting file stored in VSF can be downloaded to the NMS user s PC using System Greeting Download under system list. In system list, click on the system from which individual system greeting file is to be downloaded; individual system greeting files of each position are displayed in System Greeting Download. The target individual system greeting file can be downloaded to NMS user s PC by clicking on the system greeting file in System Greeting Download. 65

71 5. Reviewing System Info and Status 5.1 System Info Screen The System Information page gives basic information on the system selected in System Explorer, including Attendant, CO Group, and Station Group information. It also provides device inventory information that shows a summary of System capacity and component devices. To access the System Info screen: From the NMS menu, click on the System Info tab Using System Explorer The System Explorer (left-hand frame of main screen) displays each system and system group configured in ipecs NMS in a menu tree structure. Each system in the tree can be expanded to display basic configuration (CO lines, stations and etc. or other devices). An ipecs system or device (CO, Station, etc.) is selected from System Explorer for the page view. To access System Info for a system, highlight the system in System Explorer, then click the [System Info] on the NMS menu System Information View The System Information view displays the basic network configuration of the selected system. Information displayed is derived from the ipecs system database. For details on each of the items listed, refer to the ipecs Admin and Maintenance Manual. 66

72 5.1.3 Attendant, CO and Station Group Information Views Selecting the [Attendant], [CO Group] or [Station Group] displays the associated page view with basic information on the specific characteristic of the ipecs system selected in System Explorer. 67

73 For more details on individual items shown, refer to the ipecs Admin and Maintenance Manual. By clicking on the [Excel Report] button, you can download an Excel format file containing the configuration information of the selected system. The Excel sheets for system, attendant, CO group and station group information are shown by clicking corresponding tabs at the bottom of the Excel workbook. 5.2 Device Inventory Page Device Inventory Information provides overall system capacity and device inventory information of a selected system or system group. The page for this feature can be entered by clicking on the [Device Inventory] tab menu System Device Inventory System Device Inventory is the device inventory information of one system. In order to retrieve and display system device inventory information, enter Device Inventory page by clicking [Device Inventory] tab menu, select a target system in System Explorer, and click [Load Current Data] button, then the device inventory information of the selected system will be displayed as a 68

74 list of table fields. System Information table shows the system name, address, and firmware version information, and System Capacity table shows the number of devices and channels (ports) of the selected system. Device Information shows the list of devices of the system and the number of modules of the corresponding device type. By clicking [Excel Report] button, Excel format file for the device inventory information of the selected system can be downloaded System Group Device Inventory System Group Device Inventory is the device inventory information of a system group and its sub-groups. In order to retrieve and display system group device inventory information, select 69

75 the [Device Inventory] tab from the System Info menu. Select a target system group in System Explorer, and click [Load Current Data] button, then the device inventory information of the selected system group and its sub-groups will be displayed as a list of table fields. Group Information table - shows the system group name, and the number of systems that belong to the system group and its sub-groups System Capacity table - shows the number of devices and channels (ports) of the selected system group and its sub-groups Device Information - shows the list of devices of the system group and its sub-groups, and the number of modules of the corresponding device type. By clicking on the [Excel Report] button, Excel format file for the device inventory information of the selected system group can be downloaded. 70

76 5.3 Status Page The Status pages view real-time information on the state of devices and channels registered to the ipecs system device (CO, Station, Etc.) highlighted in System Explorer. On the page are the Device Base Status, CO channel Status and Station Channel Status view controls, selecting the control displays the desired view. To view a Status page, select a system and device type in System Explorer, select Status from the NMS menu bar, then select the desired status view. Of course the device type in System Explorer can be changed and the Status page view will change appropriately Device Based Status View The Device Base Status view displays the status of the device type highlighted in System Explorer for the ipecs system. 71

77 The main section of the window is a listing of all of the devices of the specific type (CO, Station, Etc.) and the state of the device. The device list includes: Column Device No. Device Type IP Address Firmware Version Location Mode Device State Description Device No. is the device sequence number on ipecs Web Admin, and is assigned by MFIM to each registered ipecs device with a unique number. The name of the device type. IP address of the device Firmware version of the device Location of a device configured when registering the device to the system. There are four location modes of Local, Remote, Local-Remote, and Remote RSGM. Device State shows the operation and registration status of a device. The states are Disconnected, Registering, Active, T-Net, Downloading, Out-of Service and N/A. In the upper right is the channel status area. The channel status is shown with an icon. The various status icons are defined in the upper section and the status of each channel associated with the device is displayed below. At the bottom of the channel status area is the Channel Information chart with details on the channel highlighted in the channels status area. Note the channel information content will vary slightly for each device type. 72

78 Below the channel information are the Device Information and the Device Network Information charts. The Device Information listed includes: Field Name Dev No. Device Type Firmware Version CPU Type Number of Channels Device Class/Order Service Switch Remarks Description Device No. is the device sequence number on ipecs Web Admin, and is assigned by MFIM to each registered ipecs device with a unique sequence number. The name of the device type Firmware version of the device CPU type in the device The number of channels of the device Devices are grouped by their functionality to make Device Class, and the classes are CO Gateway, Station, MISC Gateway, VSF Gateway, MCIM Gateway, WTIM Gateway, UCS Server and Not Defined. Order is the order of the device within its device class. The position of the service switch on the front panel of gateway device. The value can be Normal or Service. The Remark field value of System & Device IP Address (PGM 102~103) on ipecs Web Admin. This field is for additional information of each device entered by system administrator. The Device Network Information includes: Field Name IP Address MAC Address NAPT IP Address Location Mode ARP Usage Reg. Signal Type T-Net Reg. Type Zone Number Description IP address of the device MAC address of the device This is the WAN side IP address translated by NAPT router where the remote mode device is installed behind the NAPT router Location of a device configured when registering the device to the system. There are four location modes of Local, Remote, Local-Remote, and Remote RSGM. The ARP field value of System & Device IP Address (PGM 102~103) on ipecs Web Admin. If this field is set to ON, ARP protocol is used to get MAC address for the packet exchange between local mode device and MFIM. If this is set to OFF, the MAC address information exchanged during registration process is used instead of using ARP protocol. Local mode devices can utilize either of multicast or unicast signaling for device registration. Multicast signaling supports automatic configuration and registration feature for Plug&Play of local mode devices. Remote and localremote devices always use unicast signaling. This field shows the T-Net configuration and registration status of a device, and the values are Not T-Net, T-Net Registered, T-Net Register Failed, LM-Registered and LM-Register Failed. The zone number to which the device belongs. Device zone number is configured using Device Zone Number (PGM 436) on ipecs Web Admin. 73

79 Examples of the page view for CO, Station and Etc. device types follows. Note the WTIM channel status indicates the status of the DECT Base station connections. If a Base is connected and working, the status is Connect, if not connected, the status is out-ofservice (Out-Svc). 74

80 If the station or CO status is Forward, current forward configuration information can be displayed by clicking on the Status field. The information of CO, Station and Etc. devices of a selected system can be downloaded and saved in an Excel format file by clicking on the [Excel Report] button. The picture above shows an example of the downloaded Excel report file. The Excel sheets for CO, Station and Etc. device information are shown by clicking on the corresponding tabs at the bottom of the Excel program CO Channel Status View The main section of the CO channel Status view shows all CO channels registered to the ipecs system selected in System Explorer. Each channel of all CO/IP devices (PSTN, PRI, BRI, and VoIP modules) is represented graphically with icons indicating the real-time status of the channel. The right side of the screen shows the channel information and the Device and Network Information charts for the highlighted CO channel as in the Device Based Status view. Refer to section for more detail. 75

81 To open the CO Channel Status view, select the desired system in System Explorer, select [Status], and then select [CO Channel Status]. In order to show the CO channels of a specific CO type, click the corresponding CO type button, and to show all the CO channels again, click [CO Channel Status] menu tab Station Channel Status View The main section of the Station channel Status view shows all station channels registered to the ipecs system selected in System Explorer. Each channel of all stations is represented graphically with icons indicating the real-time status of the channel. The right-side of the screen shows the channel information and the Device and Network Information charts for the highlighted station channel as in the Device Based Status view (refer to Section 5.2.1). 76

82 To open the Station Channel Status view, select on the desired system in System Explorer, select [Status], and then select [Station Channel Status]. In order to show the station channels of a specific station type, click the corresponding station type button, and to show all the station channels again, click [Station Channel Status] menu tab. 77

83 6. Alarm/Fault Management ipecs NMS receives event notification messages from each registered ipecs system. Event messages are analyzed and, based on Alarm/Fault Configuration, section 6.2, events are logged and stored. If assigned, User accounts with management authority for the ipecs system are immediately notified by of the event. The ipecs NMS Event Log stores up to 10,000 event records for each registered ipecs system. The Event Log can be searched, analyzed and output as an Excel file as outlined in section 6.1 below. 6.1 Alarm/Fault Analysis Screen The Alarm/Fault Analysis screen includes tools to isolate and search events from registered ipecs systems stored in the NMS Event Log. Events from a specific system, of a specific type, status and level can be isolated and searched based on event codes, location and date. Each event record includes a record number, a delete check box and status check box. The status check box indicates the management status of the record, new or checked. In addition, each record includes fields for the following: 78

84 Field Name Code Description The code associated with the specific event message from ipecs systems. Refer to Appendix 2 for the message codes and definition. Event Description Description of the event message from ipecs systems. Refer to Appendix 2. Type Level NMS Time System Name Location The type of the event message. There are three types of event, System, Fault and Alarm. The level of severity assigned for the event. There are three levels, Critical, Major and Minor. The time when the event message was received by ipecs NMS The ipecs system name that sent the event message The location (device) where the event occurred. To view the Alarm/Fault Analysis screen, click [Alarm/Fault Analysis] tab on the Alarm/Fault menu bar Event Log Analysis Prior to any analysis of the Event Log, the entire Event Log or the events of a system should be exposed. To load the entire log: Clear the Selected System text box, check the Status, Type and Level check boxes, and after clearing the the search criteria box, select [Load Log Data]. This will load the entire Event Log including all event messages from all registered systems. To load the event log of a specific system: Select the desired ipecs system in System Explorer (the name should display in the Selected System text box), and then follow the same procedure above. To perform an analysis: Check the appropriate Status, Type and Level boxes; enter the search criteria (code or code range, fault location and time and date of occurrence, then click [Search]. To output the analysis: Click [Excel Report], which will save the event log to an Excel formatted file as shown. 79

85 6.2 Alarm/Fault Configuration ipecs NMS logs three types of events, Alarm, Fault and System. The list and description of events reported to ipecs NMS by ipecs systems is given in Appendix 2. Each event has a code and is assigned a level of importance, critical, major, or minor. The default level for each event is defined by the ipecs system but can be changed to support a specific need. Should a specific event code occur, the User accounts assigned management authority for the ipecs system can receive an notification. Note that for notification, the NMS mail server must be configured on the NMS management page (section 4.2.1), the User account must be assigned to receive notification in the User management pages (section 4.3), and the User account must be assigned to receive notification for the system on the System Management Configuration page (Section 4.4.1). To alert a NMS client with an audible alarm when an alarm/fault occurs: Check the Audible Alarm box of the desired event. The ipecs NMS event log stores only event codes assigned for storage; this can be used to remove events considered insignificant for a given analysis. To configure events and notification: Select the [Alarm/Fault Config] tab from the Alarm/Fault menu bar; after modifying the desired event configuration, click [Save] to implement the changes. 80

86 When an alarm/fault event occurs, an alarm sound is played depending on the Audible Alarm of Alarm/Fault Summary settings; this setting is toggled every time the [Audible Alarm - XXX] button is clicked (One Time, Repeat, and Disabled). To stop the alarm sound when the Audible Alarm is set to Repeat, click [Alarm/Fault Summary] or [Go to Alarm/Fault] buttons, or click the [Alarm/Fault Analysis] menu tab. When an Alarm/Fault occurs, the color of [Alarm/Fault Summary] button changes to orange; the button color will change back to its original color by clicking on either the [Alarm/Fault Summary], [Go to Alarm/Fault], or [Alarm/Fault Analysis] menu tab. 81

87 7. Call Statistics Management ipecs NMS collects statistics on calls to and from registered systems as well as within the systems. With these statistics, ipecs NMS generates user configured Traffic analysis, DECT statistics and Station Message Detail Recording (SMDR) reports. These reports are useful in determining traffic loads and for cost allocations. Call statistic collection and analysis are managed via the Call Statistics menu under the [Call Stats] selection on the NMS menu. The Call Stats menu includes the following selections: Traffic Analysis analyze collected call data Traffic Config configure call statistic collection SMDR Analysis analyze collected SMDR data SMDR Statistics provides graphs and tables based on SMDR data DECT Statistics provides DECT traffic information To view the Call Statistics menu, click [Call Stat] on the NMS menu. 7.1 Call Traffic Analysis As shown in the figure below, the initial Call Traffic Analysis page provides the tools to define the desired traffic analysis report. Here the report subject, type and period are defined as well as characteristics of the graphical output. 82

88 To structure a report: Select a system in System Explorer, and select the Report Subject (the report only includes calls associated with the selected subject) from the list. Attendant Completed Calls CO Group Voice Mail Select the Report Type. Daily, use Yesterday, Today, Last 7 Days or Last 4 Weeks as the Report period (For Last 7 Days and Last 4 Weeks, Call Traffic Configuration is needed.) Hourly, use Yesterday or Today as the Report period Select a Report Period. When Attendant or CO Group is selected as the subject, select the Attendant or CO group to consider for the report. Select a Graph Subject, the subject will appear to the left of the y-axis of the graph. Graph Subjects available varies based on the Report Subject selected above, and Graph Components varies depending on the Graph Subject selection. The charts below define the available y-axis for each Report Subject. Report Subject -Attendant Graph Subject Description Graph Component Total Call Calls routed to the attendant (except group & recalls) Total Call Held Call Calls held by the attendant Abandoned Call Total Held Call Time Call times for each attendant status (talk, held, idle) Held-Abandoned Available Time Talk Time Answer Delay Delay time before call is answered or abandoned by caller. Held Time Answer Delay No-Answer Delay Denied Report Subject - Completed Call Graph Subject Description Graph Component Completed Call Number of completed calls Completed Call Report Subject CO Group Graph Subject Description Graph Component CO Group Usage Number of line seizures of the group for each type of call (total, incoming, outgoing and overflow) Total Seizure Incoming Seizure 83

89 Graph Subject Description Graph Component Outgoing Seizure Group Overflow All CO Busy Total time that all CO/IP lines in the group were simultaneously busy All CO Busy Report Subject - Voice Mail Graph Subject Description Graph Component Voice Mail Number of voice mail (VSF/VMIM) service Requested requests/denials Denied Select the Graph Component. Select the Graph Type, line or bar. Click [Load Log Data] ipecs NMS will load data from the call statistics database and generate a graph and tabular report as shown below. The Graph Subject, Component and Type can be changed and are reflected immediately to provide the best representation of the data. The tabular report for each Report Subject varies, a sample of each subject report with explanation of each column is provided below. 84

90 Field Name NO Year Month Day Hour Total-C Ans-C Abdn-C Held-C H-Abdn Avail-T Talk-T Held-T NoAns-D Ans-D Report Subject - Attendant Description Record reference number The year when the traffic data was logged The month when the traffic data was logged The day when the traffic data was logged The hour when the traffic data was logged. This column is only meaningful If the Hourly Report Period is selected. Total number of calls, except group & recalls, routed to the attendant Total number of calls answered during the Analysis period Total number of calls abandoned before answer by the attendant (does not include calls abandoned while on hold) Total number of calls placed on hold by the attendant Total number of calls abandoned while on hold by the attendant Total time the attendant was available to handle new calls between one call and the next one Total time the attendant was active on calls Total time the attendant had calls on hold Average time calls were ringing or in queue for the attendant before abandoned Average time calls rang before answer by the attendant Field Name Year Month Report Subject Completed Call Description The year when the traffic data was logged. The month when the traffic data was logged. 85

91 Field Name Day Hour Completed Call Description The day when the traffic data was logged. The hour when the traffic data was logged. This column is only meaningful If the Hourly Report Period is selected. Number of completed calls. Field Name Year Month Day Hour CO Group Total Seizure In-Seizure Out-Seizure Grp-Overflow All-CO-Busy Report Subject CO Group Description The year when the traffic data was logged. The month when the traffic data was logged. The day when the traffic data was logged The hour when the traffic data was logged. This column is only meaningful If the Hourly Report Period is selected. CO/IP group number Total number of times CO/IP lines in the group were used for any call Total number of incoming calls answered for CO/IP lines in the group Total number of outgoing calls attempted on CO/IP lines in the group Total number of times group-overflow had been occurred Total time that all CO/IP lines in the group were simultaneously busy 86

92 Field Name Year Month Day Hour Requested Denied Report Subject Voice Mail Description The year when the traffic data was logged. The month when the traffic data was logged. The day when the traffic data was logged. The hour when the traffic data was logged. This column is only meaningful If the Hourly Report Period is selected. Total number of voice mail service requests Total number of denied voice mail service requests By clicking on the [Excel Report] button, you can download an Excel format file for the traffic table data. 87

93 7.2 Call Traffic Configuration To provide Traffic Analysis, ipecs NMS must retrieve and store call traffic statistics from the ipecs system. If enabled, ipecs NMS will request traffic statistics from the ipecs system on a daily basis at 1 am. To enable retrieval and storage of traffic statistics, select [Traffic Config] on the Call Statistics menu, click the check box in the Daily Report field for the desired system, click [Save] to save and apply selections. 7.3 SMDR Analysis SMDR Analysis provides the means to analyze SMDR data downloaded from a registered ipecs system applying various search and sort operations. The page for this feature can be viewed by clicking on the [SMDR Analysis] tab on the Call Statistics menu. 88

94 On the analysis screen, the type of calls (incoming, outgoing, transfer, extension) and various Abandoned Call, external connected party disconnects before answer, records can also be selected for analysis. The records can then be searched by station numbers, CO numbers, call time (duration), date, time, dialed number, ring time (duration), costs and account code. The resulting records are displayed in tabular form with each of the selection and search fields. To start the analysis, first the NMS SMDR log must be loaded with the SMDR data from an ipecs system. The target system for SMDR analysis should be selected first by clicking the system in System Explorer, which displays the system name in the Selected System field. Then, in the SMDR File field, select [Browse ] button to show file open window, and locate the SMDR file. To load the file into the NMS log, click [Load Log Data]. Or, if the SMDR file is not selected or SMDR File field is cleared by clicking [Clear] button, SMDR file is downloaded directly from selected ipecs system into NMS local database after clicking [Load Log Data] button. After reading the SMDR file data into the application, the records may be analyzed with the ipecs NMS tools. To perform an analysis, select the Call Type and complete the desired search fields and click [Search]. NOTE: NMS will ignore any blank search fields during a search. The analysis screen then displays the tabular SMDR report. 89

95 Additional search operations can be performed and are immediately reflected in the table. After modifying Call Type (Direction) and Search Fields, click [Search] to perform a new search. The example above shows a table generated when all normal calls were searched for station 3000 to 3010 and CO 1 to 3 on Feb, 7, In order to download and save the data shown in the SMDR table as an Excel format file, click [Excel Report] button. The picture above shows an example of downloaded Excel file. By clicking [Download SMDR File] button, SMDR file can be downloaded from the selected ipecs system and saved in the NMS user s PC. 7.4 SMDR Statistics SMDR Statistics provides additional presentations of the results from the most recent SMDR Analysis, refer to section 7.3. Results are provided in graphical and tabular formats. After completing an analysis, this page can be entered by clicking [SMDR Statistics] on the Call Statistics menu. 90

96 The Selected System and SMDR File fields cannot be changed here, but just show the system and SMDR file names that were configured and used in SMDR Analysis. These fields can only be changed in SMDR Analysis menu. Additional graphs and tables can be generated by selecting an x and y axis. To apply the selected x and y axis select the type of graph, line or bar. 7.5 DECT Statistics The DECT Statistics screen provides DECT statistics information such as traffic, call, end-of-call, cell, RF access, and station statistics of a DECT gateway as well as the statistics information for all the DECT stations registered to an MFIM. The page for this feature can be entered by clicking [DECT Statistics] tab menu. 91

97 DECT statistics can be classified into two parts. One is the statistics information collected and managed by MFIM, and provides statistics information for all the DECT stations registered to the MFIM. The other one is the statistics information collected and managed by each DECT gateway, and provides various statistics information such as traffic, call, end-of-call, cell, RF access, station statistics of a DECT gateway. As the first step, the target system for DECT statistics should be selected using System Explorer, and then either of [MFIM] or [DECT G/W] is to be selected in order to specify whether the information collected by MFIM or the information from DECT gateway is to be used for data retrieval. The types and meanings of the statistics information provided by MFIM Statistics and DECT G/W Statistics are as follows. Table Name Field Name Description MFIM Statistics DECT G/W Statistics All DECT Station Statistics Traffic Statistics Call Statistics End-of-Call Statistics Cell Statistics RF Access Statistics Station Statistics This provides the statistics data of the number of total and abnormal calls for all the DECT stations registered to an MFIM. The statistics data are collected and managed by MFIM. This provides the statistics data of the wireless hold time and traffic density of a DECT gateway. This provides the statistics data of incoming and outgoing calls for each cell. This provides the statistics data of normal and abnormal end of calls for each cell. This provides the statistics data of the frequency usage for each slot of a selected cell. This provides the statistics data of channel access, handover, and their loads (%) for each cell. This provides the information for normal & abnormal end of calls and the last cell where a DECT station has been most recently located. MFIM Statistics information is retrieved directly from MFIM because its data are collected and managed in MFIM. However, because DECT G/W Statistics data are collected in each DECT gateway, the data should be sent from DECT gateway to MFIM and then retrieved from MFIM to ipecs-nms, which causes some processing delay. All the statistics information received from MFIM is stored into NMS local database, and then presented to NMS users as tables of statistics information. 92

98 After storing the statistics data into NMS local database, NMS user can utilize the information previously stored in the database in order to get the last referenced data (with minimal processing delay). Or, if the current statistics information is needed, all the data can be retrieved again, stored into NMS local database, and then presented to NMS users MFIM Statistics MFIM Statistics information is collected and managed in MFIM, and provides the statistics of total number of calls and abnormal calls for all the DECT stations registered to the MFIM. After checking Selected System field and the [MFIM] radio-button to be selected, check if Statistics Time field shows a date and time. The Statistics Time field value means the date and time when MFIM statistics information was retrieved from MFIM and stored into NMS local database. So, if this field shows a date and time, the statistics data previously stored in NMS local database can be retrieved by clicking [Load Existing Data] button. If this field is blank, it means there is no previously stored MFIM statistics data in NMS local database. In this case, current MFIM Statistics data may be retrieved from MFIM by clicking [Load Current Data] button, and the received data will be stored in NMS local database and then presented to NMS user as a table of statistics information. After clicking on the [Load Current Data] button, current MFIM Statistics information is sent to ipecs-nms, stored in NMS local database, and then presented to the NMS user as a statistics table. While in process, the Loading Status field displays the current status of the procedure, and the types and meanings of the status messages are as follows. Loading Status MFIM Data Requested Description The first step that designates the data request state from ipecs- NMS to MFIM for MFIM statistics data. 93

99 Loading Status Loading Data (NMS MFIM) Description The second step that designates the state of the transmission of MFIM statistics data from MFIM to ipecs-nms. The last step that designates the completion of the transmission of Data Loading Completed MFIM statistics data, and the storage of the data into NMS local database. MFIM statistics data (e.g. number of Call Drops, or other counter values) can be cleared to 0 and statistics data accumulation re-started from the beginning, by clicking on the [Clear Statistics] button. Because this does not remove the statistics data currently stored in NMS local database, the NMS user is still able to retrieve statistics data from NMS local database by clicking [Load Existing Data] button. In order to download and save the currently loaded MFIM statistics data as an Excel format file, click on the [Excel Report] button. The picture above shows an example of the downloaded Excel file. All DECT Station Statistics provides the statistics of total number of calls and abnormal calls for all the DECT stations registered to the MFIM. The meaning of each table field is as follows. Field Name Total Call Description Total number of calls including both normal and abnormal calls. Number of call drops caused by power-off or disconnection of wireless channel. (The Call Drop figure inside the parentheses designates the proportion (%) of call drops to the total number of calls) 94

100 Field Name Description Counted when a DECT station cannot receive an incoming call (no response for No Response signaling messages) due to power-off or other reasons. (The figure inside the parentheses designates the proportion (%) of no responses to the total number of calls) Counted when a call cannot be made because all the codec channels of a DECT Codec Unavailable gateway are already used for other calls. (The figure inside the parentheses designates the proportion (%) of codec unavailable cases to the total number of calls) DECT G/W Statistics DECT G/W Statistics information is collected and managed in each DECT gateway, and provides various statistics information such as traffic, call, end-of-call, cell, RF access, station statistics of a DECT gateway. After checking Selected System field and the [DECT G/W] radio-button to be selected, click on the target DECT gateway in the list of DECT gateways registered to the MFIM. The Statistics Time field value means the date and time when DECT G/W Statistics information was retrieved and stored into NMS local database. So, if this field shows a date and time, the statistics data previously stored in NMS local database can be retrieved by clicking [Load Existing Data] button. If this field is blank, it means there is no previously stored DECT G/W Statistics data in NMS local database. In this case, current DECT G/W Statistics data can be retrieved from MFIM by clicking [Load Current Data] button, and the received data will be stored in NMS local database and then presented to NMS user as tables of statistics information. 95

101 After clicking [Load Current Data] button, current DECT G/W Statistics information is sent to ipecs-nms, stored in NMS local database, and then presented to NMS user as statistics tables. This needs additional procedure and takes relatively longer time than retrieving existing data directly from NMS local database using [Load Existing Data] button. So, in order to give more information about the steps of information retrieval process, Loading Status field displays the current status of the procedure, and the types and meanings of the status messages as listed. Loading Status DECT Data Requested Loading Data (MFIM DECT) Description The first step that designates the data request state from ipecs- NMS to MFIM for DECT G/W statistics data. The second step that designates the state of the transmission of DECT G/W statistics data from DECT gateway to MFIM. The third step that designates the completion of the transmission of Data Loaded to MFIM DECT G/W statistics from DECT gateway, and the storage of the data into a memory space in MFIM. Loading Data (NMS MFIM) The forth step that designates the state of the transmission of DECT G/W statistics data from MFIM to ipecs-nms. The last step that designates the completion of the transmission of Data Loading Completed DECT G/W statistics data from MFIM, and the storage of the data into NMS local database. During the statistics data request and transmission, it is possible to receive an error caused by problems in network communication or in the DECT gateway itself. The types and meanings of the error messages are as follows. Loading Error Description The data transmission from DECT gateway to MFIM has not been No Data in MFIM properly performed due to the internal problem of the DECT gateway. Invalid Data from DECT Data Not Available Malformed or invalid data message has been sent from DECT gateway. DECT gateway had not been properly registered to MFIM when the statistics data were requested to the DECT gateway. 96

102 If it is needed to clear DECT G/W statistics data (e.g. number of Incoming Calls, or other counter values) into 0 and start statistics data accumulation from the beginning, user may click [Clear Statistics] button to initialize the accumulated statistics data in DECT gateway. Because this does not remove the statistics data currently stored in NMS local database, NMS user is still able to retrieve statistics data from NMS local database by clicking [Load Existing Data] button. In order to download and save the currently loaded DECT G/W statistics data as an Excel format file, click on the [Excel Report] button. The picture above shows an example of the downloaded Excel report file. The Excel sheets for DECT G/W traffic, call, end-of-call, cell, RF access and station statistics are shown by clicking corresponding tabs at the bottom of the Excel worksheet. DECT G/W Statistics provides various statistics information such as traffic, call, end-of-call, cell, RF access, station statistics of a DECT gateway. This information can be retrieved by clicking [Load Existing Data] or [Load Current Data] button, and each type of statistics information can be presented by clicking one of the DECT G/W Statistics Type radio-buttons corresponding to the type of statistics information DECT G/W Traffic Statistics DECT G/W Traffic Statistics table is displayed by clicking Traffic radio-button in DECT G/W Statistics Type, and provides the statistics data of the wireless hold time and traffic density of a DECT gateway. 97

103 This table shows statistics data for Total No. of Calls with Hold Time, Total Hold Time, Maximum Call Time, Minimum Call Time, Average Hold Time, and Traffic Density (ELANG). The meanings of the table fields are as follows. (The time fields in the table can have values between 0~ in the unit of seconds, and if the value exceeds the maximum value, FFFFFFFFF will be displayed to indicate overflow.) Field Name Total Number of Calls with Hold Time Total Hold Time Maximum Call Time Minimum Call Time Average Hold Time Description Total number of calls for which wireless connections were completely made. Sum of the wireless connection holding time of each call. The longest wireless holding time among all the calls made on the DECT gateway. (The time for failed calls is not counted.) The shortest wireless holding time among all the calls made on the DECT gateway. (The time for failed calls is not counted.) Average wireless holding time. Traffic density of the DECT gateway. Erlang is calculated by the following Traffic Density (ERLANG) formula. Erlang = (Average Hold Time x Total Number of Calls) / 3600 second DECT G/W Call Statistics DECT G/W Call Statistics table is displayed by clicking Call radio-button in DECT G/W Statistics Type, and provides the statistics data of incoming and outgoing calls for each cell. This table shows statistics data for Incoming calls, Outgoing calls, and the Total number of calls. The meanings of the table fields are as follows. (The table fields can have values between 0~99999, and if the value exceeds the maximum 98

104 value, FFFFF will be displayed to indicate overflow.) Field Name Incoming Outgoing Total Description Number of incoming calls to DECT stations in the cell. Number of outgoing calls from DECT stations in the cell. Sum of incoming and outgoing calls DECT G/W End of Call Statistics DECT G/W End of Call Statistics table is displayed by clicking End of Call radio-button in DECT G/W Statistics Type, and provides the statistics data of normal and abnormal end of calls for each cell. This table shows statistics data for Normal Call, Abnormal Call ( Call Fail, MSG Error, No Subs., No RF Channel ), and No Response. The meanings of the table fields are as follows. (The table fields can have values between 0~99999, and if the value exceeds the maximum value, FFFFF will be displayed to indicate overflow.) Field Name Normal Call Abnormal Call Call Fail MSG Error No Subs. No RF Channel Description Number of calls that were released normally. Number of calls that were released abnormally. This type is assorted into four sub-types such as Call Fail, MSG Error, No Subs., No RF Channel. Number of call releases caused by disconnection of wireless channels, timer expiration, etc. Number of call releases caused by signaling message error. Number of call releases caused by trying to make call to non-subscribed wireless terminal. Number of call releases due to no available RF channel. 99

105 Field Name Description Number of call releases caused by no signaling response from wireless No Response terminal. ( No Response does not provide statistics data counted for each cell.) Total Sum of Normal Call, Abnormal Call, and No Response field values DECT G/W Cell Statistics DECT G/W Cell Statistics table is displayed by clicking Cell radio-button in DECT G/W Statistics Type, and provides the statistics data of the frequency usage for each slot of a selected cell. This table shows statistics data of the frequency usage for each slot of a selected cell, and the cell can be selected by clicking on the target cell in the list of cells. The meanings of the table fields are as follows. (The table fields can have values between 0~99999, and if the value exceeds the maximum value, FFFFF will be displayed to indicate overflow.) Field Name Freq x Sum Description Number of access to the frequency channel of the slot. Number of wireless channel access to the slot over all the frequency numbers DECT G/W RF Access Statistics DECT G/W RF Access Statistics table is displayed by clicking RF Access radio-button in DECT G/W Statistics Type, and provides the statistics data of channel access, handover, and their loads (%) for each cell. 100

106 This table shows statistics data for channel access, handover, and their load (%) information, and the handover statistics is subdivided into IntraCell, InterCell, InterCHO, IA-IR CHO, and IA- IA CHO statistics. The meanings of the table fields are as follows. (The Load (%) fields are displayed in the unit of percent, and the other table fields can have values between 0~999999, and if the value exceeds the maximum value, FFFFFF will be displayed to indicate overflow.) Field Name CH Access {CH Access} Load (%) IntraCell InterCell InterCHO IA-IR CHO IA-IA CHO {Handover} Load (%) Total (%) Description Number of wireless channel access to a cell Proportion (%) of wireless channel access to a cell to all wireless connections including handover. Number of BHOs (Bearer Handover) occurred within a cell. Number of BHOs (Bearer Handover) occurred among cells. Number of CHOs (Connection Handover) occurred among DECT gateways. Number of CHOs (Connection Handover) occurred among the cells of a DECT gateway. Number of CHOs (Connection Handover) occurred within a cell of a DECT gateway. Proportion (%) of wireless handovers (within a cell or among cells) to all wireless connections. Sum of the handover load values. (In the table above, BHO is the abbreviation of Bearer HandOver, and means a type of handover occurred in MAC layer. CHO is the abbreviation of Connection HandOver, and mean a type of handover occurred in DLC (Data Link Control) layer that is above MAC layer.) 101

107 DECT G/W Station Statistics DECT G/W Station Statistics table is displayed by clicking Station radio-button in DECT G/W Statistics Type, and provides the information for normal & abnormal end of calls and the last cell where a DECT station has been most recently located. This table shows statistics data for Last Cell, Normal Call, Abnormal Call and No Response for each station. The meanings of the table fields are as follows. (The table fields can have values between 0~999999, and if the value exceeds the maximum value, FFFFFF will be displayed to indicate overflow.) Field Name Last Cell Normal Call Abnormal Call No Response Sum Description The last cell where a DECT station was most recently located Number of calls that were released normally Number of calls that were released abnormally Number of call releases caused by no signaling response from DECT station. Sum of the column values over all the DECT stations in the table 102

108 8. Network Traffic Monitoring Network Traffic Monitoring provides the means to monitor the network traffic and the connection status of a network device. For general network devices, Ping test, Traceroute test, and network traffic monitoring features are implemented, and for ipecs devices, Ping test and traffic monitoring features are provided. The pages for these features can be entered by clicking [Network Traffic] tab on the top level menu. 8.1 Ping Test Ping Test provides functions to check the connection status and the packet delay time between ipecs-nms and a general network device, and can be entered by clicking [Ping] tab menu. Before performing Ping test, the IP address of the target network device, and the interval & count for Ping packet transmission should be configured in Ping Configuration & Operation. For Interval field, one of 5, 10, 20, 30 second options can be selected using the combo-box, and Count field can have a value between 1~ Estimated Time field displays an estimated completion time calculated from the values of Interval and Count fields, and is a read-only field that does not require input from user. After the configuration is completed, Ping test can be started by clicking [Start] button. If it is 103

109 needed to stop the Ping test before the completion of the test (before the estimated time), user may click [Stop] button to force the test to be stopped. After the Ping test is started, real-time graph and table that show the result from each Ping test are displayed below. The graph and table that show the result of Ping test can be displayed in three types of time period such as Live Data, Last 60 Minutes, and Last 24 Hours. The real-time graph and table are displayed by clicking [Live Data] button. [Last 60 Minutes] and [Last 24 Hours] buttons are used for displaying the graphs and tables for last 60 minutes and 24 hours from the moment the corresponding button was clicked. (After the test has been finished, they are displayed from the moment of the completion of the test.) The graph in the picture above shows the changes in RTT (Round-Trip Time), which is the time between the transmission of a Ping packet and the reception of the response packet. RTT is often used to estimate the packet delay time in a network environment. The table below the graph shows the information from the Ping test, and the meanings of the table fields are as follows. 104

110 Table Name Field Name Description The IP address of the device that responded to the Ping packet sent Reply IP Address by ipecs-nms. Normally, this is to be the same IP address as the target IP Address configured in Ping Configuration & Operation. Abbreviation of Round-Trip Time. This is the elapsed time until the RTT reception of the response packet to a Ping packet sent by ipecs- Live Data Last 60 Minutes Last 24 Hours Average RTT Delay Variation Time Reply IP Address RTT Average RTT Delay Variation Time Reply IP Address RTT Average RTT NMS. The overall average of the RTT values from all the Ping tests calculated since the beginning of the Ping test. The difference in value between the RTT values of the previous row and the current row of the table. The time when the Ping packet was actually transmitted to the target device. The Time interval may not be exactly same as the Interval value configured in Ping Configuration & Operation depending on the operational or processing load on the NMS server. The IP address of the device that responded to the Ping packet sent by ipecs-nms. Normally, this is to be the same IP address as the target IP Address configured in Ping Configuration & Operation. This is the average of the RTT values from the Ping tests for last 1 minute (actually, the time between the previous row and the current row in the table). The overall average of the RTT values from all the Ping tests calculated since the beginning of the Ping test. The difference in value between the RTT values of the previous row and the current row of the table. The time when the Ping packet was actually transmitted to the target device. The Time interval may not be exactly same as the Interval value configured in Ping Configuration & Operation depending on the operational or processing load on the NMS server. The IP address of the device that responded to the Ping packet sent by ipecs-nms. Normally, this is to be the same IP address as the target IP Address configured in Ping Configuration & Operation. This is the average of the RTT values from the Ping tests for last 1 hour (actually, the time between the previous row and the current row in the table). The overall average of the RTT values from all the Ping tests calculated since the beginning of the Ping test. 105

111 Table Name Field Name Description Delay Variation The difference in value between the RTT values of the previous row and the current row of the table. The time when the Ping packet was actually transmitted to the target Time device. The Time interval may not be exactly same as the Interval value configured in Ping Configuration & Operation depending on the operational or processing load on the NMS server. After the Ping operation is finished, the operation result data can be downloaded and saved as an Excel format file by clicking on the [Excel Report] button. The picture above shows an example of a downloaded Excel report file. The Excel sheets for Live Data, Last 60 Minutes and Last 24 Hours are shown by clicking corresponding tabs at the bottom of Excel program. 8.2 Traceroute Test Traceroute Test provides functions to check the packet delivery path and packet delay time for each hop to the destination between ipecs-nms and a general network device, utilizing ICMP message and the TTL field in IP packet header. The page for this feature can be entered by clicking [Traceroute] tab menu. 106

112 Before performing Traceroute test, the IP address of the target network device and the interval for Traceroute packet transmission should be configured in Traceroute Configuration & Operation. For Interval field, one of 3, 4, 5 second options can be selected using the combobox. After the configuration is completed, Traceroute test can be started by clicking [Start] button. If it is needed to stop the Traceroute test before the completion of the test (before the destination device has been reached), user may click on the [Stop] button to force the test to be stopped. After a Traceroute test is started, real-time graph and table that show the Traceroute result for each hop to the destination are displayed below. The graph of Traceroute test shows the changes in RTT (Round-Trip Time) for each hop to the destination, in real-time. RTT is the time between the transmission of a Traceroute packet and the reception of the response packet, and is often used to designate the packet delay time in a network environment. The table below the graph shows the hops on the path to the destination in sequence, and the RTT from the three trials to the same hop and their average value are displayed together with the Reply IP Address information. The meanings of the table fields are as follows. Field Name Description The IP address of the device that responded with ICMP Time Exceeded message to the Reply IP Address Traceroute packet sent by ipecs-nms. Normally, this is the IP address of a router on the path to the destination or of the target device itself. 107

113 This is the elapsed time until the reception of the response packet to the first Traceroute RTT-1 packet to a device on the path to the destination or the target device. (RTT is the abbreviation of Round-Trip Time.) RTT-2 RTT-3 Average RTT This is the elapsed time until the reception of the response packet to the second Traceroute packet to a device on the path to the destination or the target device. This is the elapsed time until the reception of the response packet to the third Traceroute packet to a device on the path to the destination or the target device. The average of the RTT values from the three Traceroute trials to the same destination. After the Traceroute operation is finished, the operation result data can be downloaded and saved as an Excel format file by clicking on the [Excel Report] button. The picture above shows an example of downloaded Excel report file. 8.3 Device Network Traffic Device Network Traffic provides functions to retrieve network device information and its interface configuration/status, and to monitor the real-time network traffic of the device using SNMP messages. The page for this feature can be entered by clicking [Device Traffic] tab menu. 108

114 Device Network Traffic has two functional parts. One is to retrieve and display general device information and network interface information with Device SNMP Configuration & Operation, and the other one is to present graph and table of real-time network traffic information with Polling Configuration & Operation. These two parts are functionally separated, but because Polling Configuration & Operation part can be working based on the information retrieved in Device SNMP Configuration & Operation, Device SNMP Configuration & Operation part should always be configured and executed first. In order to retrieve device information, the IP Address, SNMP Port, and SNMP Community information should be entered. For SNMP Port field, the standard SNMP port number 161 can usually be used, but if the target device uses different port number for SNMP communication, that port number should be entered. For Community field, public can usually be used for general network devices, but if the target device uses different SNMP community string, that string should be entered. After the configuration is finished, general device information and its interface information can be retrieved and displayed by clicking [Get Device Information] button. Device Information displays general information of the target network device, and the table below shows the device s network interface information. The meanings of the fields are as follows. 109

115 Table Name Field Name Description A textual description of the entity. This value normally includes the full Description name and version identification of the system's hardware type, software operating-system, and networking software. An administratively-assigned name for this managed node. By Name convention, this is the node's fully-qualified domain name. If the Device Information Interface Information Up Time No. of Interface Packet Forward Default TTL Interface Info. name is unknown, the value is the zero-length string. The time (in hundredths of a second) since the network management portion of the system was last re-initialized. The number of network interfaces (regardless of their current state) present on the device. The indication of whether this entity is acting as an IP router in respect to the forwarding of datagrams received by, but not addressed to, this entity. The default value inserted into the Time-To-Live field of the IP header of datagrams originated at this entity, whenever a TTL value is not supplied by the transport layer protocol. A textual string containing information about the interface. This string normally includes the name of the manufacturer, the product name and the version of the interface hardware/software. The desired state of the interface. The Testing state indicates that no operational packets can be passed. When a managed device initializes, all interfaces start with Admin Status in the Down Admin Status state. As a result of either explicit management action or per configuration information retained by the managed device, Admin Status is then changed to either the Up or Testing states (or remains in the Down state). The current operational state of the interface. The Testing state indicates that no operational packets can be passed. If Admin Status is Down then Oper Status should be Down. If Admin Status is Oper Status changed to Up then Oper Status should change to Up if the interface is ready to transmit and receive network traffic. It should remain in the Down state if and only if there is a fault that prevents it from going to the Up state. It should remain in the Not Present state if the interface has missing (typically, hardware) components. 110

116 Table Name Field Name Description The interface's address at its protocol sub-layer. For example, for an MAC Address 802.x interface, this object normally contains a MAC address. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length. The size of the largest packet which can be sent/received on the MTU interface, specified in octets. For interfaces that are used for transmitting network datagrams, this is the size of the largest network datagram that can be sent on the interface. An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those Speed where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero. In order to monitor real-time network traffic of the target device, the interval and count for polling network traffic data should be configured in Polling Configuration & Operation. For Interval field, one of 10, 20, 30 second options can be selected using the combo-box, and Count field can have a value between 1~ Estimated Time field displays an estimated completion time calculated from the values of Interval and Count fields, and is a read-only field that does not require input from user. After the configuration is completed, network traffic monitoring can be started by clicking [Start] button. If it is needed to stop the traffic monitoring before the traffic polling is finished (before the estimated time), user may click [Stop] button to force the traffic polling to be stopped. After traffic monitoring is started, real-time graph and table that show the result from each traffic polling are displayed below. 111

117 The graph in the picture above shows in real time the number of incoming and outgoing packets that occurred during the polling interval, and the traffic table shows the traffic data occurred within the interval as well as the accumulated traffic data. The meanings of the table fields are as follows. Field Name In-Interval Out-Interval Total In Description The number of packets received during the time period configured in Interval field of Polling Configuration & Operation. The number of packets transmitted during the time period configured in Interval field of Polling Configuration & Operation. The total number of input datagrams received from interfaces, including those received in error. The number of input IP datagrams for which no problems were encountered to prevent In-Discard their continued processing, but which were discarded (e.g., for lack of buffer space). Note that this counter does not include any datagrams discarded while awaiting re-assembly. In-Error The number of input datagrams discarded due to errors in their IP headers, the use of unknown or unsupported protocol, or invalid IP address to be received at this device. The total number of IP datagrams which local IP user protocols (including ICMP) Total Out supplied to IP in requests for transmission, and the datagrams for which this device was not their final IP destination, as a result of which an attempt was made to find a route to forward them to that final destination. 112

118 Field Name Description The number of output IP datagrams for which no problem was encountered to prevent Out-Discard their transmission to their destination, but which were discarded (e.g., for lack of buffer space). The number of IP datagrams discarded because no route could be found to transmit Out-Error them to their destination. Note that this includes any datagrams which the device cannot route because all of its default routers are down. The time when ipecs-nms retrieved traffic information from the target device. The Time Time interval may not be exactly same as the Interval value configured in Polling Configuration & Operation depending on the operational or processing load on the NMS server. The graph and table that show the result of network traffic polling can be displayed in three types of time period such as Live Data, Last 60 Minutes, and Last 24 Hours. The real-time graph and table are displayed by clicking [Live Data] button. [Last 60 Minutes] and [Last 24 Hours] buttons are used for displaying the graphs and tables for last 60 minutes and 24 hours from the moment the corresponding button was clicked. (After the polling has been finished, they are displayed from the moment of the completion of the polling operation.) And, the interface information that was initially retrieved from the target device by clicking [Get Device Information] button can be retrieved from NMS local database by clicking [Device Information] button. After the Device Traffic operation is finished, the operation result data can be downloaded and saved as an Excel format file by clicking on the [Excel Report] button. 113

119 The picture above shows an example of downloaded Excel report file. The Excel sheets for Live Data, Last 60 Minutes and Last 24 Hours are shown by clicking corresponding tabs at the bottom of Excel workbook. 8.4 ipecs Device Ping Test ipecs Device Ping Test provides functions to check the connection status and the packet delay time between MFIM and an ipecs device that is registered to the MFIM, and this operation is performed by the Ping message implemented in ipecs protocol. The page for this feature can be entered by clicking [ipecs Ping] tab menu. Before executing ipecs Device Ping Test, the target ipecs device to be tested should be selected. After the ipecs system to which the target device is registered is selected in System Explorer, the name of the system is displayed in System field of Selected ipecs Device part, and the list of registered ipecs devices are listed below as a table of devices. 114

120 The target device can be selected in the device table by clicking on the device item, and after the selection is made, the Device Type and IP Address information is displayed in the corresponding fields of Selected ipecs Device part. (If the target device is located behind an NAPT router, NAPT IP Address value will also be displayed.) Before performing Ping test for the selected device, the interval and count for Ping packet transmission should be configured in Ping Configuration & Operation. For Interval field, one of 5, 10, 20, 30 second options can be selected using the combo-box, and Count field can have a value between 1~ Estimated Time field displays an estimated completion time calculated from the values of Interval and Count fields, and is a read-only field that does not require input from user. ipecs Device Ping Test is different from the Ping test for general network device (11.1 Ping Test) in that the Ping packet is sent from MFIM to the target device (rather than sent from ipecs-nms), and so ipecs Device Ping Test can be used to check the network connection and packet delay time between MFIM and the target ipecs device. After the configuration is completed, Ping test can be started by clicking [Start] button. If it is needed to stop the Ping test before the completion of the test (before the estimated time), user may click [Stop] button to force the test to be stopped. After the Ping test is started, real-time graph and table that show the result from each Ping test will be displayed below. 115

121 The graph and table that show the result of Ping test can be displayed in three types of time period such as Live Data, Last 60 Minutes, and Last 24 Hours. The real-time graph and table are displayed by clicking [Live Data] button. [Last 60 Minutes] and [Last 24 Hours] buttons are used for displaying the graphs and tables for last 60 minutes and 24 hours from the moment the corresponding button was clicked. (After the test has been finished, they are displayed from the moment of the completion of the test.) The graph in the picture above shows the changes in RTT (Round-Trip Time), which is the time between the transmission of a Ping packet and the reception of the response packet, and can be used to estimate the packet delay time between MFIM and the selected ipecs device. The table below the graph shows the information from the Ping test, and the meanings of the table fields are as follows. Table Name Field Name Description The IP address of the device that responded to the Ping packet sent Live Data Reply IP Address by MFIM. Normally, this is to be the same IP address as the target IP Address configured in Selected ipecs Device. 116

122 Table Name Field Name Description RTT Average RTT Delay Variation Abbreviation of Round-Trip Time. This is the elapsed time until the reception of the response packet to a Ping packet sent by MFIM. The overall average of the RTT values from all the Ping tests calculated since the beginning of the Ping test. The difference in value between the RTT values of the previous row and the current row of the table. The time when ipecs-nms retrieved Ping test result from MFIM. Time The Time interval may not be exactly same as the Interval value configured in Ping Configuration & Operation depending on the operational or processing load on the NMS server. The IP address of the device that responded to the Ping packet sent Reply IP Address by MFIM. Normally, this is to be the same IP address as the target IP Address configured in Selected ipecs Device. This is the average of the RTT values from the Ping tests for last 1 RTT minute (actually, the time between the previous row and the current Last 60 Minutes Last 24 Hours Average RTT Delay Variation Time Reply IP Address RTT Average RTT Delay Variation row in the table). The overall average of the RTT values from all the Ping tests calculated since the beginning of the Ping test. The difference in value between the RTT values of the previous row and the current row of the table. The time when ipecs-nms retrieved Ping test result from MFIM. The Time interval may not be exactly same as the Interval value configured in Ping Configuration & Operation depending on the operational or processing load on the NMS server. The IP address of the device that responded to the Ping packet sent by MFIM. Normally, this is to be the same IP address as the target IP Address configured in Selected ipecs Device. This is the average of the RTT values from the Ping tests for last 1 hour (actually, the time between the previous row and the current row in the table). The overall average of the RTT values from all the Ping tests calculated since the beginning of the Ping test. The difference in value between the RTT values of the previous row and the current row of the table. 117

123 Table Name Field Name Description The time when ipecs-nms retrieved Ping test result from MFIM. Time The Time interval may not be exactly same as the Interval value configured in Ping Configuration & Operation depending on the operational or processing load on the NMS server. After ipecs Device Ping operation is finished, the operation result data can be downloaded and saved as an Excel format file by clicking on the [Excel Report] button. The picture above shows an example of downloaded Excel report file. The Excel sheets for Live Data, Last 60 Minutes and Last 24 Hours are shown by clicking corresponding tabs at the bottom of the Excel workbook. 8.5 ipecs Device Network Traffic ipecs Device Network Traffic provides functions to monitor the real-time network traffic of the selected ipecs device. The page for this feature can be entered by clicking [ipecs Traffic] tab menu. (This feature can only be applied to the gateways developed for and after ipecs Phase 4 and LIP-7000 series IP-Phones.) 118

124 Before executing ipecs Device Network Traffic monitoring, the target ipecs device to be monitored should be selected. After the ipecs system to which the target device is registered is selected in System Explorer, the name of the system is displayed in System field of Selected ipecs Device part, and the list of registered ipecs devices are listed below as a table of devices. The target device can be selected in the device table by clicking on the device item, and after the selection is made, the Device Type and IP Address information is displayed in the corresponding fields of Selected ipecs Device part. (If the target device is located behind an NAPT router, NAPT IP Address value will also be displayed.) 119

125 In order to monitor real-time network traffic of the target device, the interval and count for polling network traffic data should be configured in Polling Configuration & Operation. For Interval field, one of 10, 20, 30 second options can be selected using the combo-box, and Count field can have a value between 1~ Estimated Time field displays an estimated completion time calculated from the values of Interval and Count fields, and is a read-only field that does not require input from user. For Type field, either of Overall Packet or RTP Packet can be selected. Overall Packet means all type of transmitted or received packets, and RTP Packet means media packets such as voice or video packets delivered using RTP. After the configuration is completed, network traffic monitoring can be started by clicking [Start] button. If it is needed to stop the traffic monitoring before the traffic polling is finished (before the estimated time), user may click [Stop] button to force the traffic polling to be stopped. After traffic monitoring is started, real-time graph and table that show the result from each traffic polling are displayed below. The graph in the picture above shows in real time the number of incoming and outgoing packets that occurred during the polling interval, and the traffic table shows the traffic data occurred within the interval as well as the accumulated traffic data. The meanings of the table fields are as follows. Table Name Field Name Description Overall Packet In-Interval Out-Interval The number of overall packets received during the time period configured in Interval field of Polling Configuration & Operation. The number of overall packets transmitted during the time period configured in Interval field of Polling Configuration & Operation. 120

126 Table Name Field Name Description Packets In Bytes In ErrPackets In Packets Out Bytes Out ErrPackets Out The number of overall packets received at the selected device. The number of bytes for all the packets received at the selected device. The number of input packets discarded due to packet errors. The number of overall packets transmitted from the selected device. The number of bytes for all the packets transmitted from the selected device. The number of outgoing packets discarded due to problems at the network device driver. The time when ipecs-nms retrieved overall traffic information of the target device from MFIM. The Time interval may not be exactly Time same as the Interval value configured in Polling Configuration & Operation depending on the operational or processing load on the NMS server. In-Interval Out-Interval The number of RTP packets received during the time period configured in Interval field of Polling Configuration & Operation. The number of RTP packets transmitted during the time period configured in Interval field of Polling Configuration & Operation. The number of RTP packets received at the selected device, and Packets In those packets may include audio and/or video packets for media communication. RTP Packet The number of RTP packets transmitted from the selected device, Packets Out and those packets may include audio and/or video packets for media communication. The time when ipecs-nms retrieved RTP traffic information of the target device from MFIM. The Time interval may not be exactly Time same as the Interval value configured in Polling Configuration & Operation depending on the operational or processing load on the NMS server. After ipecs Device Traffic operation is finished, the operation result data can be downloaded and saved as an Excel format file by clicking on the [Excel Report] button. 121

127 The picture above shows an example of downloaded Excel report file. The Excel sheets for Live Data, Last 60 Minutes and Last 24 Hours are shown by clicking corresponding tabs at the bottom of the Excel workbook. 122

128 9. Log & History Management Log & History Management is for checking and managing the access & operation history of ipecs-nms, and provides NMS Access Log and NMS Operation Log for the management of the history data. The pages for these features can be entered by clicking [Log] tab on the NMS menu. 9.1 NMS Access Log NMS Access Log provides means to store the access history of ipecs-nms as log data, and to search and manage the access log. The page for this feature can be entered by clicking [NMS Access Log] on the Log menu. In order to load NMS Access Log data, click [Load Log Data] button. After reading the log data, ipecs-nms performs search operations using the search options in Log Status and Search Fields and displays the resulting data in tabular format. The Access Log data may be displayed on multiple pages, and in this case, the target page can be displayed using Table Page combo-box or left/right arrow buttons. The types and meanings of Log Status and Search Fields are as follows. 123

129 Table Name Field Description Log Status New New indicates the log record has not been checked by the administrator. When login or logout event happens on ipecs-nms, a new log record is generated and stored with New status. If this check-box is set for searching, the items with New status will be searched. Checked indicates the log record has been checked by the administrator. After Checked a new item is checked, the status of the record is changed to the Checked status and saved. If this check-box is set for searching, the items with Checked status will be searched. User ID This field is for entering target User ID to be used for searching. If this field has no value (blank), ipecs-nms ignores this field and searches for all User IDs. This field is for entering the code number of target log type as follows (Login) : User logged in to ipecs-nms Search Fields Code (Logout) : User logged out from ipecs-nms If this field has no value (blank), ipecs-nms ignores this field and searches for all code types. This field is for entering the time or time range when the login/logout events Log Time occurred. If this field has no value (remains as blank), ipecs-nms ignores this field and searches for all time periods. After modifying the field values of Log Status and Search Fields, a new search can be performed by clicking [Search], and the search results display in the log table. For Log Time field, all date/time fields can be entered. However, the user may skip entering the fields from the rightmost fields. In other words, date/time fields may be entered from the left and stopped leaving right side fields blanks. The example above shows the configuration and its search result for the log data of all status (both New & Checked ) that happened between March 1, 2008 March 5, 2008 where user ID is nmsop and the code number is 200 (Login). 124

130 In order to change the status of a log item to Checked, click the check-box in Status field of the target record, and click [Apply Status Changes] to save and apply the change of status. If New check-box is clicked, the status is changed to Checked, and if clicked again, it will be changed back to New. In order to delete a target log item, select the item by clicking the check-box in Del field, and then click [Delete Selected Events]. Or, if all the searched data is to be deleted, click [Delete All] button. The log data currently listed in the log table can be downloaded and saved as Excel formatted file by clicking [Excel Report]. The above is an example of downloaded Excel report file. 125

131 9.2 NMS Operation Log The NMS Operation Log provides means to store the NMS operation history as log data, and search and manage the Operation Log. The page for this feature can be entered by clicking [NMS Operation Log] on the Log menu. In order to load NMS Operation Log data, click [Load Log Data]. After the log data is loaded to the application, ipecs-nms performs search operations using the options in Operation Class & Status and Search Fields and displays the resulting data in tabular format. In the screen capture above, Selected System field was cleared to load the log data for all ipecs systems registered to ipecs NMS. The operation log data may be displayed on multiple pages, and in this case, the target page can be displayed using Table Page combo-box or left/right arrow buttons. 126

132 If Selected System field is set by clicking the target system in System Explorer, the log data related only to the selected system will be listed after clicking [Load Log Data]. If Selected System field is cleared by clicking [Clear] before clicking [Load Log Data], the log data for all the systems displays. The types and meanings of Operation Class & Status and Search Fields are as follows. Table Name Field Name Description System Operations related to System management. User Operations related to User management. Operation NMS Operations related to NMS management. Class Alarm/Fault Operations related to Alarm/Fault management. Call Statistics Operations related to Call statistics New indicates a log item not checked by the administrator. When an New operational event occurs, a new record is generated and stored with New status. If this check-box is set for searching, the items with New status will be Log Status searched. Checked indicates a log item checked by the administrator. After a new item is Checked checked, the status of the item is changed to Checked status and saved. If this check-box is set for searching, the items with Checked status will be searched. This field is for entering a target User ID to be used for searching. If this field User ID has no value (blank), ipecs NMS ignores this field and searches for all the User IDs. This field is for entering the code number of the target operation, refer to the Search Code table below. If this field has no value (blank), ipecs NMS ignores this field and Fields searches for all code types. This field is for entering the time or time range when the operational events Log Time occurred. If this field has no value (blank), ipecs NMS ignores this field and searches for all time periods. The table below is a listing and definition of the various NMS operation codes. Operation Class Code Name System 300 (Reserved) 310 System Added 311 System Deleted 312 System Modified 320 System Group Added 321 System Group Deleted 322 System Group Modified 330 Web Admin Password Set 331 Web Admin Started 340 Firmware Upgrade 341 Firmware Upgrade Cancel 350 System DB Upload 351 System DB Upload Cancel 352 System DB Scheduled Backup 127

133 Operation Class Code Name 353 System DB Scheduled Backup Cancel 360 Prompt Upload 361 Prompt Upload Cancel 362 Individual Upload 363 Individual Upload Cancel 370 System Greeting Upload 371 System Greeting Upload Cancel 372 Individual Greeting Upload 373 Individual Greeting Upload Cancel 400 User Added 401 User Deleted User 402 User Modified 403 System Assignment Modified 410 User Force Log-out 500 Mail Server Set 501 External Link Set NMS 502 KeepAlive Interval Set 503 NHIC NMS Service Set 504 Trap Community Set 600 Log Item Checked Alarm/Fault 601 Log Item Deleted 602 Alarm Notification Set Call Statistics 700 Traffic Configuration Set 701 SMDR Data Set After modifying the field values of Operation Class & Status and Search Fields, a new search can be performed by clicking [Search], the search results display in the operation log table. For the Log Time field, all the date/time fields can be entered. However, the user may skip entering the fields from the rightmost fields. In other words, date/time fields may be entered from the left and stopped leaving right side fields blanks. 128

134 The example above shows the configuration and results for the Main Office s log data for any status and all operation classes between March 1, 2008 March 5, 2008 where user ID is admin and the code number is 701 (SMDR Data Set). In order to change the status of a log item to New, click on the check-box in Status field of the target record, and then click [Apply Status Changes] to save and apply the change of status. If New check-box is clicked, the status is changed to Checked, and if clicked again, it will be changed back to New status. In order to delete a target log item, select the item by clicking the check-box in Del field, and then click [Delete Selected Events] button to delete the selected item. Or, if all search data is to be deleted, click [Delete All] button. The log data currently listed on the log table can be downloaded and saved as Excel formatted file by clicking [Excel Report] button. The picture above shows an example of downloaded Excel report file. 129

135 10. NMS Database Backup & Restore The ipecs NMS Control program mentioned in section registers ipecs-nms Service to the Windows Service list and manages the NMS Service database and program operation. The earlier section discusses registration and service management. This section discusses the database management aspects of the ipecs NMS Control program. Using the control program, the NMS database can be backed up to a user defined folder and, if the server or other fault occurs, the ipecs NMS database can be restored. The control program permits a Basic Backup & Restore operation that backs up System Management, User Management, NMS Management, and the log data of Alarm/Fault Management and Log Management configuration and log databases. Entire Backup & Restore operation includes detailed information received and stored while ipecs NMS communicates with the ipecs system. The following sections detail operation of both the Basic and Entire Backup and Restore operations Basic Backup & Restore The first step in the basic backup and restore operation is to find and open the ipecs NMS Control program. The ipecs_mns-control.exe program should be located under the ipecs NMS folder in the LG-Nortel folder located in the Program Files directory. When located, double click on the program to open the control window. (Or, from the Windows Start menu, select LG-Nortel > ipecs NMS > Launch ipecs_nms_control. exe to execute it.) Backup & restore for both Basic and Entire Databases should be performed after the ipecs NMS Service stops running, by clicking [Stop Service]. However, in case it is not possible to stop ipecs NMS Service (operational reason), Basic Backup can be performed while ipecs NMS Service is operating, but the changed information during the backup process may not be applied to the database backup file. 130

136 Basic Backup Operation After starting the ipecs NMS Control program and stopping the ipecs NMS Service, a backup may be created. To create the backup, browse to the desired backup location and enter the file name to use for the backup file, and click [Backup]. A DOS command prompt may appear during the creation of the backup file. After complete, check the target folder and assure a backup copy was made. Then, restart the ipecs NMS Service by clicking [Start Service] on the control program, and end the ipecs NMS Control program by selecting [Close] Basic Restore Operation As with the Basic backup operation, the ipecs NMS Control program must be started (refer to Section 9.1). In addition, it is necessary to create an empty database by first unloading the service and deleting the existing NMS basic database. Then the empty database is created and the service is loaded, which allows the database backup file to be restored. This is required in case the existing database is corrupted and assures the corruption will not affect the restored database. 131

137 First open the ipecs NMS Control program window, locate the control.exe file in the LG-Nortel folder in the Program Files directory and double click on the file. This will open the control window. Once the window opens, click [Unload Service] to stop and unregister the service with Windows Service list. After the service is unregistered, the [Delete Database] control activates, click the [Delete Database] control, which removes the existing database. Once the database is deleted, create a new empty database by clicking the [Create Database] control. Now the database backup file can be restored safely to ipecs NMS. Browse to the location and select the backup file, then click [Open]. Click the now active [Start Service & Restore] control, which will load the backup database and restart the ipecs NMS Service program. 132

138 Before restoration begins, you will be asked to enter the PostgreSQL password entered when the program was first loaded, refer to section Enter the password to complete the restoration process. The database is restored to match the Backup database and ipecs NMS Service is loaded and restarted. Click [Close] to close the ipecs NMS Control program Entire Backup & Restore The first step in entire database backup and restore operation is to open the ipecs NMS Control program and stop and unregister the service program with the Windows Service list. The ipecs_mns_control.exe program should be located under the ipecs NMS folder in the LG-Nortel folder located in the Program Files directory. When located, double click on the program to open the control window. (Or, from the Windows Start menu, select LG-Nortel > ipecs NMS > Launch ipecs_nms_control.exe to execute it.) In the control window, select [Unload Service], which will stop and unregister the ipecs NMS Service program. 133

139 Entire Database Backup Operation After stopping and unloading the ipecs NMS Service with the ipecs NMS Control program, a backup may be created. Next, click [Browse ] next to the Entire Database text box and browse to the folder where the backup file will be stored. Next append the file name to the folder path. Note the extension all automatically appends to the folder and file name. Next, click [Backup], a DOS command window appears and, when the backup operation is complete this window will close. After the DOS window closes, check the folder to assure the backup file was created. Activate NMS Service by clicking [Load Service] and [Start Service] then, close the ipecs NMS Control program by clicking [Close] to restore normal operation of ipecs NMS Entire Database Restore Operation Before restoring the entire Database, the ipecs NMS Control program must be started, see section 9.1. In addition, it is necessary to create an empty database by first unloading the service and deleting the existing NMS basic database. Then an empty database is created, which allows the database backup file to be restored. This is required in case the existing database is corrupted and assures the corruption will not affect the restored database. 134

140 To open the control program, locate ipecs NMS Control program in the LG-Nortel folder of the Program files directory and double click the file. (Or, from the Windows Start menu, select LG-Nortel > ipecs NMS > Launch ipecs_nms_control.exe to execute it.) Once the window opens, click [Unload Service] to stop and unregister the service with Windows Service list. After the service is unloaded, the [Delete Database] control activates, click the [Delete Database] control, which removes the existing database. Once the database is deleted, create a new empty database by clicking the [Create Database] control. 135

141 Now the Entire Database backup file can be restored safely to ipecs NMS. Browse to or enter the location and name of the backup file. Click the now active [Restore] control, which will load the backup database. Before restoration begins, you will be asked to enter the PostgreSQL password that was entered when the program was first loaded, refer to section Enter the password to complete the restoration process. The database is restored to match the Backup database. Click [Load Service] and [Start Service] to activate ipecs NMS Service. Click [Close] to close the ipecs NMS Control program. 136

142 NMS Feature Description & Operation Issue 1 Appendix 1 ipecs System Set-up for NMS Before registering ipecs systems in ipecs-nms, the ipecs system should be configured for NMS operation. Login to ipecs Web Admin, refer to the ipecs Administration & Maintenance Manual. Select SNMP Attribute (PGM 196) from System Data group to enter the NMS Configuration screen. SNMP Attributes, as shown on the screen, are divided into three categories: SNMP Agent, SNMP Security, and SNMP Trap. The SNMP Agent field, SNMP Service enables the SNMP agent running in the ipecs Call Server. The SNMP port field defines the udp port used for communications from the ipecs system for SNMP messages. This port should not be changed. In SNMP Security are the Read Only and Read Write SNMP Community fields, 4 to 16 characters. The SNMP community designates an SNMP communication group to which an SNMP message belongs, and is also a logical relationship between the SNMP agent (ipecs A-1-1

143 system) and SNMP manager (ipecs NMS). The SNMP community settings must be the same for the ipecs system and the ipecs NMS server. Read Only Community (default=public) Defines a community string used when the ipecs NMS reads data from the ipecs system. Read Write Community (default=private) Defines the community string used when ipecs NMS reads or writes data to the ipecs system. Although the ipecs system can accept packets from any SNMP manger (ipecs NMS), for improved security, the IP address of specific servers can be defined and allowed Read Only or Read Write access. It is recommended that the system be assigned with the IP address of a specific NMS server with Read Write access. The SNMP Trap configuration defines the Trap Community, and the Trap Destination, which includes the IP Address of the SNMP manager, ipecs NMS, and the message type. The Trap Community designates a communication group to which a Trap message belongs, and is also a logical relationship between the SNMP agent (ipecs system) and SNMP manager (ipecs NMS). This 4 to 16 character string should be the same as the Trap community string defined in the ipecs-nms. The Trap community should be same for all the ipecs systems registered to an ipecs-nms server whereas the SNMP community may be defined with different strings for each ipecs system. The Trap Destination defines the IP address of the ipecs NMS server and the port, 162. Enter the IP address of the NMS server but, the port should not be changed. The pull down menu next to the address is used to define the address type. Three values are available: Trap message type is defined in SNMPv1, but because ipecs-nms and the ipecs system use, and the Trap type message is not recommended Notification message type are, sent from the SNMP agent once without checking the reception of the message. Inform message type requires a response of receipt from the SNMP manager. If the agent does not receive a response, the message is resent. Inform messages A1-2

144 are intended for use in environments with high packet loss; however, use of the Inform message type may detrimentally affect the ipecs system performance. After finishing all Configuration items, click on the [Save] button. A1-3

145 NMS Feature Description & Operation Issue 1 Appendix 2 ipecs System Information View ipecs NMS logs three types of events, Alarm, Fault and System. Each event is classified as critical, major or minor and is referenced with a code. Events logged in ipecs NMS are listed below. Alarm events, Codes 100 ~ 399 Code Name Type Level Location State Description < CPU Overload Occurred > Occurred when CPU usage rate becomes ON higher than 80%. * Detailed Information : CPU performance availability 101 CPU Overload Alarm MAJ MFIM - CPU Idle 15% < CPU Overload Cleared > Occurred when CPU usage rate becomes less OFF than 80%. * Detailed Information : CPU performance availability - CPU Idle 25% < Interface Link Down > Occurred when the status of the network ON interface (e.g. eth0, eth1, wan0) of MFIM becomes Down. * Detailed Information : Network interface name 103 Link Up/Down Alarm CRI I/F(#) - eth0 < Interface Link Up > Occurred when the status of the network OFF interface (e.g. eth0, eth1, wan0) of MFIM becomes Up. * Detailed Information : Network interface name - eth0 A2-1

146 Code Name Type Level Location State Description < Standby MFIM Down > In case of CPU redundancy configuration, this event is occurred when the status of stand-by MFIM becomes Down. The stand-by MFIM is determined to be Down when one or more of the following three conditions are met. 1) The link status of LAN2 is detected to be Down. 2) Stand-by MFIM has not sent redundancy ON status message longer than 1 minute. 3) The status of call processing application of 105 Stand-by MFIM Status Alarm MAJ MFIM stand-by MFIM is determined to be abnormal. * Detailed Information : The cause of stand-by MFIM status Down - LAN2 POWER DOWN - NO STATUS MESSAGE - NO APPLICATION MESSAGE - CPU REDUNDANCY USAGE ON (Occurred when administrator enables CPU Redundancy Usage) < Standby MFIM Up > In case of CPU redundancy configuration, this OFF event is occurred when the status of stand-by MFIM becomes Up. * Detail Information : None A2-2

147 Code Name Type Level Location State Description < Device Down > Occurred when a device becomes disconnected from MFIM. This event may occur when - the device is powered off, ON - the device is restarted (reset), 201 Device Up/Down Alarm CRI DEV(#) - the network connection between the device and MFIM is abnormal or not stable, - MFIM does not properly communicate with the device. * Detailed Information : None < Device Up > OFF Occurred when a device becomes connected to MFIM. * Detailed Information : None < Station Locked up > Occurred when a station has gone off-hook ON under none-conversation state until howler tone 205 Station Lock/Unlock Alarm MIN STA(#) is received. * Detailed Information : None < Station Unlocked > OFF Occurred when the locked station becomes onhook. * Detailed Information : None < SMDR Memory Full Occurred > Occurred when the memory space for SMDR data becomes full. SMDR (SMDR Memory Capacity Full is the state that 211 Memory Alarm MAJ MFIM ON the memory space remains available for less Capacity than 50 SMDR records.) * Detailed Information : None * Related Attendant Alarm : SMDR BUFFER FULL A2-3

148 Code Name Type Level Location State Description < SMDR Memory Full Cleared > OFF Occurred when SMDR Memory Capacity Full condition becomes cleared. * Detailed Information : None < VSF Memory Full Occurred > Occurred when the memory space of VSF ON gateway becomes full. * Detailed Information : None 213 VSF Memory Capacity Alarm MAJ DEV(#) * Related Attendant Alarm : VSF WARNING: MEMORY FULL < VSF Memory Full Cleared > OFF Occurred when VSF Memory Capacity Full condition becomes cleared. * Detailed Information : None < System Disconnected > Occurred when the communication between NMS and ipecs system becomes disconnected. NMS determines that the connection between ON NMS and MFIM is disconnected when it does 301 System Connectivity Alarm CRI NMS not receive KeepAlive Trap message from MFIM for 5 minutes. (This may happen when MFIM is powered off, or the network is abnormal or not stable, etc.) * Detailed Information : None < System Connected > OFF Occurred when the connection between NMS and ipecs system is recovered. * Detailed Information : None A2-4

149 Fault events, Codes 400 ~ 699 Code Name Type Level Location State Description < System Startup > Occurred when 10 minutes has elapsed 401 System Startup Fault CRI MFIM NONE after restarting MFIM. (After 10 minutes from restart, MFIM starts device polling, and the SNMP agent in MFIM starts working.) * Detailed Information : None < MFIM Switch Over Occurred > In case of CPU redundancy configuration, this event is occurred when a switch over between active and stand-by MFIM happens and so stand-by MFIM becomes active MFIM. The condition for the stand-by MFIM to be switched to active MFIM is as follows. 1) The link status of LAN2 is detected to be Down. 2) Active MFIM has not sent redundancy status message longer than 1 minute. 3) The status of call processing application 402 MFIM Switch Over Fault MAJ MFIM NONE of active MFIM is determined to be abnormal. 4) Active MFIM requests switch-over to stand-by MFIM. (This may happen when administrator forced switch-over using PGM450, or LAN1 of active MFIM becomes down.) * Detailed Information : The cause of switchover and the direction. - LAN2 POWER DOWN (Master -> Slave) - NO STATUS MESSAGE (Master -> Slave) - NO APPLICATION MESSAGE (Master -> Slave) - REQUEST FROM ASSOCIATED MFIM (Master -> Slave A2-5

150 Code Name Type Level Location State Description < SNMP Auth Failure > Occurred when the community string of received SNMP message is different from the one configured in MFIM. * Detailed Information : The IP address of the host that sent the SNMP message with invalid community string. < HTTP Auth Failure > Occurred when Web Admin is accessed using invalid password. * Detailed Information : The IP address of the host that accessed Web Admin using invalid password. < Remote Auth Failure > Occurred when a remote Telnet connection 403 Authentication Failure Fault MIN MFIM NONE is tried using invalid password. * Detailed Information : The IP address of the host that tried remote connection using invalid password. < Terminal Auth Failure > Occurred when serial terminal login (via RS- 232 serial connection or Telnet connection after remote login) is tried using invalid password. * Detailed Information : The IP address of the host that used invalid password, or COM1(Serial). < Keyset Auth Failure > Occurred when Keyset Admin is accessed using invalid password. * Detailed Information : The station number of the station used to access Keyset Admin using invalid password. A2-6

151 Code Name Type Level Location State Description < Station Capacity Excess Alarm > Occurred when the maximum station 411 Station Capacity Fault MIN MFIM NONE capacity has been reached and so additional station device cannot be registered. * Detailed Information : None * Related Attendant Alarm : CAPACITY OVERFLOW STA < CO Line Capacity Excess Alarm > Occurred when the maximum CO line 413 CO Line Capacity Fault MIN MFIM NONE capacity has been reached and so additional CO device cannot be registered. * Detailed Information : None * Related Attendant Alarm : CAPACITY OVERFLOW COL < DSP Alert Occurred > Occurred when DSP Alert is detected in the ON DSP of a device. * Detailed Information : DSP Alert code number 501 DSP Alert Fault MAJ DEV(#) - Code 10 < DSP Alert Cleared > Occurred when DSP Alert is cleared in the OFF DSP of a device. * Detailed Information : DSP Alert code number - Code 10 < DSP Error Occurred > Occurred when DSP Error happens in the 503 DSP Error Fault MAJ DEV(#) NONE DSP of a device. * Detailed Information : DSP Error code number - Code 10 A2-7

152 Code Name Type Level Location State Description < DECT Base Disconnected > Occurred when the connection between DECT gateway and DECT base is disconnected. ON This may happen when the cable is not properly connecting DECT gateway and DECT base, or the status of DECT base is 511 DECT Base Status Fault MAJ DEV(#) not normal. * Detailed Information : Base number - Base 1 < DECT Base Connected > Occurred when the connection between OFF DECT gateway and DECT base is recovered. * Detailed Information : Base number - Base 1 < DECT Gateway Fault > Occurred when Base or Chain connections are not stable. This may happen when the connection between DECT gateway and DECT base or the Chain connections between DECT 513 DECT GW Fault Occurred Fault MAJ DEV(#) NONE gateways are not stable (so that the connection status keeps changing between connected and disconnected states). * Detailed Information : Base number or Chain - Base 1 or Chain * Related Attendant Alarm : WTIM BASE FAULT, WTIM CHAIN FAULT < Device Line Down > 521 Device Line Up/Down Fault MAJ DEV(#) ON Occurred when the status of T1/E1/PRI line becomes Down. * Detailed Information : None * Related Attendant Alarm : DCOB FAULT A2-8

153 Code Name Type Level Location State Description < Device Line Up > OFF Occurred when the status of T1/E1/PRI line becomes Up. * Detailed Information : None < Gatekeeper Disconnected > Occurred when the connection between ON H.323 gateway (e.g. VOIM) and Gatekeeper is disconnected. 523 Gatekeeper Connectivity Fault MAJ DEV(#) * Detailed Information : None < Gatekeeper Connected > Occurred when the connection between OFF H.323 gateway (e.g. VOIM) and Gatekeeper is recovered. * Detailed Information : None < SIP Proxy Disconnected > Occurred when the connection between SIP ON gateway (e.g. VOIM) and SIP Proxy Server 525 SIP Proxy Server Connectivity Fault MAJ DEV(#) is disconnected. * Detailed Information : None < SIP Proxy Connected > Occurred when the connection between SIP OFF gateway (e.g. VOIM) and SIP Proxy Server is recovered. * Detailed Information : None < Cabinet Failure Occurred > Occurred when Fan failure or Power failure happens in an ipecs Cabinet. 601 Cabinet Fan/Power Failure Fault MAJ CABINET( #) ON * Detailed Information : The Fan number or Power (PSU) number that caused the failure. - FAN 1, POWER 2 * Related Attendant Alarm : CABINET # STS FAULT A2-9

154 Code Name Type Level Location State Description < Cabinet Failure Cleared > Occurred when the Fan failure or Power failure condition is cleared. OFF * Detailed Information : The Fan number or Power (PSU) number that was recovered from failure. - FAN 1, POWER 2 System events, Codes 700 ~ 999 Code Name Type Level Location State Description < System Reset by Admin > Occurred when ipecs system is restarted manually by administrator using Web Admin, Keyset Admin, or Terminal Maintenance. (This event is not caused by MFIM power off or reset button on the front panel of MFIM.) * Detailed Information : The cause of the 701 System Reset by Admin System CRI MFIM NONE restart (reset) - Keyset Admin - Web Admin (Reset System) - Web Admin (Delete Device) - Web Admin (System ID Information Changed) - Web Admin (System IP Information Changed) - Web Admin (CO Gateway Sequence Number Changed) - Maintenance Command A2-10

155 Code Name Type Level Location State Description < System ID Information Changed > Occurred when administrator changed nation code or numbering plan of a System ID system using Web Admin, Keyset Admin, 702 Information System MAJ MFIM NONE or Terminal Maintenance. Change * Detailed Information : Changed information - Nation Code - Numbering Plan < System IP Information Changed > Occurred when IP address information is changed by administrator using Web Admin, Keyset Admin, or Terminal Maintenance. * Detailed Information : Changed Information - MFIM/E IP Address System IP - MFIM/E Sub Net Mask 703 Information System MAJ MFIM NONE - Router IP Address Change - System IP Range Start - "System IP Range End" - "System Sub Net Mask" - "Second System IP Address" - "Second System Net Mask" - "Firewall IP Address" - "MFIM/E LAN2 Master IP Address" - "MFIM/E LAN2 Slave IP Address" - "DNS IP Address" < SNMP Reconfigured > Occurred when SNMP configuration 704 SNMP Reconfiguration System MIN MFIM NONE information is changed by administrator using Web Admin, or Terminal Maintenance. * Detailed Information : None A2-11

156 Code Name Type Level Location State Description < Database Initialized > Occurred when system database is initialized by administrator using Web Admin, or Keyset Admin. * Detailed Information : Information of initialized database - "Flexible Numbering Plan" - "Station Data" 705 Database Initialization System MAJ MFIM NONE - "CO Line Data" - "System Data" - "Station Group Data" - "ISDN Tables" - "System Timer" - "Toll Tables" - "LCR Data" - "Other Tables" - "Flexible Button" - "Networking Data" - "All Database" < File Upload Finished > Occurred when file uploading to MFIM is finished (performed by administrator using Web Admin). * Detailed Information : The result of file 706 File Upload System MIN MFIM NONE upload operation & the name of the uploaded file. - SUCCESS : GS97ME0As.rom - "FAIL (DISK SIZE)" - "FAIL (FILE NAME)" - "FAIL (FILE FORMAT)" < Firmware Download Start > 707 Firmware Download System MAJ MFIM ON Occurred when MFIM firmware downloading is started. * Detailed Information : None A2-12

157 Code Name Type Level Location State Description < Firmware Download End > Occurred when MFIM firmware OFF downloading is finished. * Detailed Information : The result of firmware download operation - SUCCESS or FAIL < Device Registered > ON Occurred when a device is newly registered, or Hot Desk user logs in. Device * Detailed Information : None 801 Registration / System MAJ DEV(#) < Device Unregistered > Deletion Occurred when a device is deleted using OFF Device Delete Feature of Web Admin, or Hot Desk user logs out. * Detailed Information : None < Admin Set Device Out-of-Service > Occurred when administrator makes a ON device into Out-of-Service state using Web Admin. 803 Device Service Status System MIN DEV(#) * Detailed Information : None < Admin Set Device I-Service > Occurred when administrator recovers a OFF device from Out-of-Service state using Web Admin. * Detailed Information : None < Device Switch Service Mode > Occurred when the Normal/Service 805 Device Service Switch Status System MAJ DEV(#) ON switch on the front panel of gateway device is moved to Service position. (If a device is in Service mode, no additional calls can be made.) * Detailed Information : None A2-13

158 Code Name Type Level Location State Description < Device Switch Normal Mode > Occurred when the Normal/Service OFF switch on the front panel of gateway device is moved to Normal position. * Detailed Information : None < Device Firmware Download Start > Occurred when device firmware ON downloading (from MFIM to device) is started. * Detailed Information : Device firmware version 807 Device Firmware Download System MAJ DEV(#) < Device Firmware Download End > Occurred when device firmware downloading is finished. OFF * Detailed Information : The result of device firmware download operation & firmware version. - "SUCCESS : 42Bc" - FAIL : 42Bc" < CO Blocked by Attendant > Occurred when administrator restricts ON outgoing access to CO/IP lines (using 809 CO Line Outgoing Block Status System MIN COL(#) attendant program code 0-7-2). * Detailed Information : None < CO Unblocked by Attendant > Occurred when administrator recovers OFF CO/IP lines from outgoing access restriction. * Detailed Information : None < CO Gateway Order Changed > 811 CO Gateway Order Change System MAJ DEV(#) NONE Occurred when administrator changed the order of CO gateways using Web Admin or Keyset Admin. * Detailed Information : None A2-14

159 Code Name Type Level Location State Description < Station Logical Number Changed > Occurred when administrator changed station number using Web Admin or Keyset Admin. (Station number can be changed for individual station, station order range, or 812 Station Number Change System MAJ STA(#) NONE station number range.) * Detailed Information : Changed station number information - "Station(1) > 2000" : for individual station - "Ordering Range 1 ~ 100 -> 2000 ~" : for station order range - Station Range 1000 ~ > 2000 ~" : for station number range < Soft Phone Log In > ON Occurred when Soft Phone (Phontage, Web Phone, UCS Client) logs in. 813 Soft Phone Log In/Out System MIN DEV(#) * Detailed Information : Station number < Soft Phone Log Out > OFF Occurred when Soft Phone (Phontage, Web Phone, UCS Client) logs out. Detailed Information : Station number < Hot Desk Log In > ON Occurred when Hot Desk user logs in. 815 Hot Desk Log In/Out System MIN DEV(#) * Detailed Information : Station number < Hot Desk Log Out > OFF Occurred when Hot Desk user logs out. * Detailed Information : Station number A2-15

026-1010 Rev 7 06-OCT-2011. Site Manager Installation Guide

026-1010 Rev 7 06-OCT-2011. Site Manager Installation Guide 026-1010 Rev 7 06-OCT-2011 Site Manager Installation Guide Retail Solutions 3240 Town Point Drive NW, Suite 100 Kennesaw, GA 30144, USA Phone: 770-425-2724 Fax: 770-425-9319 Table of Contents 1 SERVER

More information

Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc.

Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc. Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from

More information

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner

More information

Pharos Control User Guide

Pharos Control User Guide Outdoor Wireless Solution Pharos Control User Guide REV1.0.0 1910011083 Contents Contents... I Chapter 1 Quick Start Guide... 1 1.1 Introduction... 1 1.2 Installation... 1 1.3 Before Login... 8 Chapter

More information

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

Sharp Remote Device Manager (SRDM) Server Software Setup Guide Sharp Remote Device Manager (SRDM) Server Software Setup Guide This Guide explains how to install the software which is required in order to use Sharp Remote Device Manager (SRDM). SRDM is a web-based

More information

Moxa Device Manager 2.0 User s Guide

Moxa Device Manager 2.0 User s Guide First Edition, March 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa Device Manager 2.0 User Guide The software described in this manual

More information

Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015

Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015 Metalogix SharePoint Backup Publication Date: August 24, 2015 All Rights Reserved. This software is protected by copyright law and international treaties. Unauthorized reproduction or distribution of this

More information

USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION. www.pesa.com August 2014 Phone: 256.726.9200. Publication: 81-9059-0703-0, Rev. C

USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION. www.pesa.com August 2014 Phone: 256.726.9200. Publication: 81-9059-0703-0, Rev. C USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION Publication: 81-9059-0703-0, Rev. C www.pesa.com Phone: 256.726.9200 Thank You for Choosing PESA!! We appreciate your confidence in our products. PESA produces

More information

LifeSize Control Installation Guide

LifeSize Control Installation Guide LifeSize Control Installation Guide April 2005 Part Number 132-00001-001, Version 1.0 Copyright Notice Copyright 2005 LifeSize Communications. All rights reserved. LifeSize Communications has made every

More information

File Management Utility User Guide

File Management Utility User Guide File Management Utility User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held

More information

NETWORK PRINT MONITOR User Guide

NETWORK PRINT MONITOR User Guide NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable

More information

Liebert Nform Infrastructure Monitoring Software. User Manual - Version 4

Liebert Nform Infrastructure Monitoring Software. User Manual - Version 4 Liebert Nform Infrastructure Monitoring Software User Manual - Version 4 TABLE OF CONTENTS 1.0 ABOUT LIEBERT NFORM................................................1 1.1 How Do You Contact Emerson Network

More information

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link: TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link: ftp://ftp.software.ibm.com/storage/tivoli-storagemanagement/maintenance/client/v6r2/windows/x32/v623/

More information

Avalanche Remote Control User Guide. Version 4.1.3

Avalanche Remote Control User Guide. Version 4.1.3 Avalanche Remote Control User Guide Version 4.1.3 ii Copyright 2012 by Wavelink Corporation. All rights reserved. Wavelink Corporation 10808 South River Front Parkway, Suite 200 South Jordan, Utah 84095

More information

WebSpy Vantage Ultimate 2.2 Web Module Administrators Guide

WebSpy Vantage Ultimate 2.2 Web Module Administrators Guide WebSpy Vantage Ultimate 2.2 Web Module Administrators Guide This document is intended to help you get started using WebSpy Vantage Ultimate and the Web Module. For more detailed information, please see

More information

MGC WebCommander Web Server Manager

MGC WebCommander Web Server Manager MGC WebCommander Web Server Manager Installation and Configuration Guide Version 8.0 Copyright 2006 Polycom, Inc. All Rights Reserved Catalog No. DOC2138B Version 8.0 Proprietary and Confidential The information

More information

ivms-5200 Professional Web Manager User Manual

ivms-5200 Professional Web Manager User Manual ivms-5200 Professional Web Manager User Manual UD.6L0202D1651A01 Hikvision ivms-5200 Professional Web Manager User Manual This manual, as well as the software described in it, is furnished under license

More information

Diamond II v2.3 Service Pack 4 Installation Manual

Diamond II v2.3 Service Pack 4 Installation Manual Diamond II v2.3 Service Pack 4 Installation Manual P/N 460987001B ISS 26APR11 Copyright Disclaimer Trademarks and patents Intended use Software license agreement FCC compliance Certification and compliance

More information

EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014. Version 1

EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014. Version 1 EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014 Version 1 NEC EXPRESSCLUSTER X 3.x for Windows SQL Server 2014 Quick Start Guide Document Number ECX-MSSQL2014-QSG, Version

More information

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional. SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional. 33-40006-001 REV: B PCSC 3541 Challenger Street Torrance, CA 90503 Phone: (310) 303-3600

More information

SIMIAN systems. Setting up a Sitellite development environment on Windows. Sitellite Content Management System

SIMIAN systems. Setting up a Sitellite development environment on Windows. Sitellite Content Management System Setting up a Sitellite development environment on Windows Sitellite Content Management System Introduction For live deployment, it is strongly recommended that Sitellite be installed on a Unix-based operating

More information

Avaya Network Configuration Manager User Guide

Avaya Network Configuration Manager User Guide Avaya Network Configuration Manager User Guide May 2004 Avaya Network Configuration Manager User Guide Copyright Avaya Inc. 2004 ALL RIGHTS RESERVED The products, specifications, and other technical information

More information

Manual Password Depot Server 8

Manual Password Depot Server 8 Manual Password Depot Server 8 Table of Contents Introduction 4 Installation and running 6 Installation as Windows service or as Windows application... 6 Control Panel... 6 Control Panel 8 Control Panel...

More information

NMS300 Network Management System

NMS300 Network Management System NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate

More information

How To Use Gfi Mailarchiver On A Pc Or Macbook With Gfi Email From A Windows 7.5 (Windows 7) On A Microsoft Mail Server On A Gfi Server On An Ipod Or Gfi.Org (

How To Use Gfi Mailarchiver On A Pc Or Macbook With Gfi Email From A Windows 7.5 (Windows 7) On A Microsoft Mail Server On A Gfi Server On An Ipod Or Gfi.Org ( GFI MailArchiver for Exchange 4 Manual By GFI Software http://www.gfi.com Email: [email protected] Information in this document is subject to change without notice. Companies, names, and data used in examples

More information

Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide

Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide Direct Storage Access Using NetApp SnapDrive Installation & Administration Guide SnapDrive overview... 3 What SnapDrive does... 3 What SnapDrive does not do... 3 Recommendations for using SnapDrive...

More information

NETWRIX FILE SERVER CHANGE REPORTER

NETWRIX FILE SERVER CHANGE REPORTER NETWRIX FILE SERVER CHANGE REPORTER ADMINISTRATOR S GUIDE Product Version: 3.3 April/2012. Legal Notice The information in this publication is furnished for information use only, and does not constitute

More information

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Lenovo Online Data Backup User Guide Version 1.8.14

Lenovo Online Data Backup User Guide Version 1.8.14 Lenovo Online Data Backup User Guide Version 1.8.14 Contents Chapter 1: Installing Lenovo Online Data Backup...5 Downloading the Lenovo Online Data Backup Client...5 Installing the Lenovo Online Data

More information

GE Healthcare Life Sciences UNICORN 5.31. Administration and Technical Manual

GE Healthcare Life Sciences UNICORN 5.31. Administration and Technical Manual GE Healthcare Life Sciences UNICORN 5.31 Administration and Technical Manual Table of Contents Table of Contents 1 Network setup... 1.1 Network terms and concepts... 1.2 Network environment... 1.3 UNICORN

More information

Remote Backup Software User Manual V 2.0

Remote Backup Software User Manual V 2.0 Remote Backup Software User Manual V 2.0 Table of Contents Chapter 1 Welcome to Remote Backup Software... 2 1.1 Overview... 2 1.2 Computer Disposition Request... 2 1.3 Convention... 2 Chapter 2 Installing

More information

StruxureWare Power Monitoring 7.0.1

StruxureWare Power Monitoring 7.0.1 StruxureWare Power Monitoring 7.0.1 Installation Guide 7EN02-0308-01 07/2012 Contents Safety information 5 Introduction 7 Summary of topics in this guide 7 Supported operating systems and SQL Server editions

More information

Maintaining the Content Server

Maintaining the Content Server CHAPTER 7 This chapter includes the following Content Server maintenance procedures: Backing Up the Content Server, page 7-1 Restoring Files, page 7-3 Upgrading the Content Server, page 7-5 Shutting Down

More information

How To Create An Easybelle History Database On A Microsoft Powerbook 2.5.2 (Windows)

How To Create An Easybelle History Database On A Microsoft Powerbook 2.5.2 (Windows) Introduction EASYLABEL 6 has several new features for saving the history of label formats. This history can include information about when label formats were edited and printed. In order to save this history,

More information

WhatsUp Gold v16.2 Installation and Configuration Guide

WhatsUp Gold v16.2 Installation and Configuration Guide WhatsUp Gold v16.2 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.2 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines

More information

Quadro Configuration Console User's Guide. Table of Contents. Table of Contents

Quadro Configuration Console User's Guide. Table of Contents. Table of Contents Epygi Technologies Table of Contents Table of Contents About This User s Guide... 3 Introducing the Quadro Configuration Console... 4 Technical Specification... 6 Requirements... 6 System Requirements...

More information

WhatsUp Gold v16.3 Installation and Configuration Guide

WhatsUp Gold v16.3 Installation and Configuration Guide WhatsUp Gold v16.3 Installation and Configuration Guide Contents Installing and Configuring WhatsUp Gold using WhatsUp Setup Installation Overview... 1 Overview... 1 Security considerations... 2 Standard

More information

WhatsUp Gold v16.1 Installation and Configuration Guide

WhatsUp Gold v16.1 Installation and Configuration Guide WhatsUp Gold v16.1 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.1 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines

More information

Installing GFI MailSecurity

Installing GFI MailSecurity Installing GFI MailSecurity Introduction This chapter explains how to install and configure GFI MailSecurity. You can install GFI MailSecurity directly on your mail server or you can choose to install

More information

NTP Software File Auditor for NAS, EMC Edition

NTP Software File Auditor for NAS, EMC Edition NTP Software File Auditor for NAS, EMC Edition Installation Guide June 2012 This guide provides a short introduction to the installation and initial configuration of NTP Software File Auditor for NAS,

More information

Document Management System

Document Management System Document Management System User's Manual for Administrator www.microtek.com Preface Copyright Copyright 2013, Microtek International, Inc., all rights reserved. This document may not be reproduced or copied

More information

Getting Started with ESXi Embedded

Getting Started with ESXi Embedded ESXi 4.1 Embedded vcenter Server 4.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent

More information

Getting Started - The Control Panel

Getting Started - The Control Panel Table of Contents 1. Getting Started - the Control Panel Login Navigation Bar Domain Limits Domain User Account Properties Session Management 2. FTP Management Creating and Editing Users Accessing FTP

More information

Moxa Device Manager 2.3 User s Manual

Moxa Device Manager 2.3 User s Manual User s Manual Third Edition, March 2011 www.moxa.com/product 2011 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

TANDBERG MANAGEMENT SUITE 10.0

TANDBERG MANAGEMENT SUITE 10.0 TANDBERG MANAGEMENT SUITE 10.0 Installation Manual Getting Started D12786 Rev.16 This document is not to be reproduced in whole or in part without permission in writing from: Contents INTRODUCTION 3 REQUIREMENTS

More information

Mobility Services Platform 3.1.1 Software Installation Guide

Mobility Services Platform 3.1.1 Software Installation Guide Mobility Services Platform 3.1.1 Software Installation Guide Mobility Services Platform 3.1.1 Software Installation Guide 72E-100159-04 Revision D January 2008 2007 by Motorola, Inc. All rights reserved.

More information

Embarcadero Performance Center 2.7 Installation Guide

Embarcadero Performance Center 2.7 Installation Guide Embarcadero Performance Center 2.7 Installation Guide Copyright 1994-2009 Embarcadero Technologies, Inc. Embarcadero Technologies, Inc. 100 California Street, 12th Floor San Francisco, CA 94111 U.S.A.

More information

FileMaker Server 11. FileMaker Server Help

FileMaker Server 11. FileMaker Server Help FileMaker Server 11 FileMaker Server Help 2010 FileMaker, Inc. All Rights Reserved. FileMaker, Inc. 5201 Patrick Henry Drive Santa Clara, California 95054 FileMaker is a trademark of FileMaker, Inc. registered

More information

DiskPulse DISK CHANGE MONITOR

DiskPulse DISK CHANGE MONITOR DiskPulse DISK CHANGE MONITOR User Manual Version 7.9 Oct 2015 www.diskpulse.com [email protected] 1 1 DiskPulse Overview...3 2 DiskPulse Product Versions...5 3 Using Desktop Product Version...6 3.1 Product

More information

ACS CLIENT SOFTWARE USER MANUAL

ACS CLIENT SOFTWARE USER MANUAL ACS CLIENT SOFTWARE USER MANUAL 1 ACS USER GUIDE 1.1 System Requirement Recommended System Requirement OS CPU VGA RAM HDD WindowXP, Vista Pentium 4, 2Ghz 1024*768, 64MB 24bit color graphic card 1GB 20MB

More information

Backup Recording Viewer for NS

Backup Recording Viewer for NS Backup Recording Viewer for NS Installation and Operation Manual Version 1.0 Poltys, Inc. 3300 N. Main Street, Suite D, Anderson, SC 29621-4128 +1 864 642 6103, [email protected] www.poltys.com 2013 Poltys,

More information

Kaspersky Security Center Web-Console

Kaspersky Security Center Web-Console Kaspersky Security Center Web-Console User Guide CONTENTS ABOUT THIS GUIDE... 5 In this document... 5 Document conventions... 7 KASPERSKY SECURITY CENTER WEB-CONSOLE... 8 SOFTWARE REQUIREMENTS... 10 APPLICATION

More information

SysPatrol - Server Security Monitor

SysPatrol - Server Security Monitor SysPatrol Server Security Monitor User Manual Version 2.2 Sep 2013 www.flexense.com www.syspatrol.com 1 Product Overview SysPatrol is a server security monitoring solution allowing one to monitor one or

More information

Pre-Installation Checks Installation Creating Users and Quick Setup Usage Examples and Settings Appendix

Pre-Installation Checks Installation Creating Users and Quick Setup Usage Examples and Settings Appendix Standard Setup Guide 1 2 3 4 5 Pre-Installation Checks Installation Creating Users and Quick Setup Usage Examples and Settings Appendix Read this manual carefully before you use this product and keep it

More information

Desktop Surveillance Help

Desktop Surveillance Help Desktop Surveillance Help Table of Contents About... 9 What s New... 10 System Requirements... 11 Updating from Desktop Surveillance 2.6 to Desktop Surveillance 3.2... 13 Program Structure... 14 Getting

More information

PLEASE NOTE: The client data used in these manuals is purely fictional.

PLEASE NOTE: The client data used in these manuals is purely fictional. Welcome! CAREWare Quick Start guides will walk you through the basics of setting up, managing and using the main CAREWare functions. It is intended for non-technical users who just need to get basic information

More information

Docufide Client Installation Guide for Windows

Docufide Client Installation Guide for Windows Docufide Client Installation Guide for Windows This document describes the installation and operation of the Docufide Client application at the sending school installation site. The intended audience is

More information

This guide consists of the following two chapters and an appendix. Chapter 1 Installing ETERNUSmgr This chapter describes how to install ETERNUSmgr.

This guide consists of the following two chapters and an appendix. Chapter 1 Installing ETERNUSmgr This chapter describes how to install ETERNUSmgr. Preface This installation guide explains how to install the "ETERNUSmgr for Windows" storage system management software on an ETERNUS DX400 series, ETERNUS DX8000 series, ETERNUS2000, ETERNUS4000, ETERNUS8000,

More information

PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 -

PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 - Network Guide PREFACE Every effort has been made to ensure that the information in this document is complete, accurate, and up-to-date. The manufacturer assumes no responsibility for the results of errors

More information

File Auditor for NAS, Net App Edition

File Auditor for NAS, Net App Edition File Auditor for NAS, Net App Edition Installation Guide Revision 1.2 - July 2015 This guide provides a short introduction to the installation and initial configuration of NTP Software File Auditor for

More information

ClickCall. User Guide. Please read this manual carefully before operation. Retain it for future reference.

ClickCall. User Guide. Please read this manual carefully before operation. Retain it for future reference. ClickCall User Guide Please read this manual carefully before operation. Retain it for future reference. Copyright 2013 Ericsson-LG Enterprise Co., Ltd. All Rights Reserved. This material is copyrighted

More information

NSi Mobile Installation Guide. Version 6.2

NSi Mobile Installation Guide. Version 6.2 NSi Mobile Installation Guide Version 6.2 Revision History Version Date 1.0 October 2, 2012 2.0 September 18, 2013 2 CONTENTS TABLE OF CONTENTS PREFACE... 5 Purpose of this Document... 5 Version Compatibility...

More information

HP A-IMC Firewall Manager

HP A-IMC Firewall Manager HP A-IMC Firewall Manager Configuration Guide Part number: 5998-2267 Document version: 6PW101-20110805 Legal and notice information Copyright 2011 Hewlett-Packard Development Company, L.P. No part of this

More information

Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010

Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010 Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010 This document describes the different types of Unisphere management stations and tells how to install

More information

Camera Management Tool User Manual

Camera Management Tool User Manual Network Camera Camera Management Tool User Manual The Operation Guide should be read before using the network camera. ENGLISH Introduction This manual describes how to configure and operate Camera Management

More information

Charter Business Desktop Security Administrator's Guide

Charter Business Desktop Security Administrator's Guide Charter Business Desktop Security Administrator's Guide Table of Contents Chapter 1: Introduction... 4 Chapter 2: Getting Started... 5 Creating a new user... 6 Recovering and changing your password...

More information

Legal Notes. Regarding Trademarks. 2011 KYOCERA MITA Corporation

Legal Notes. Regarding Trademarks. 2011 KYOCERA MITA Corporation Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from

More information

Sage 200 Web Time & Expenses Guide

Sage 200 Web Time & Expenses Guide Sage 200 Web Time & Expenses Guide Sage (UK) Limited Copyright Statement Sage (UK) Limited, 2006. All rights reserved If this documentation includes advice or information relating to any matter other than

More information

VMware/Hyper-V Backup Plug-in User Guide

VMware/Hyper-V Backup Plug-in User Guide VMware/Hyper-V Backup Plug-in User Guide COPYRIGHT No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying,

More information

Avalanche Site Edition

Avalanche Site Edition Avalanche Site Edition Version 4.8 avse ug 48 20090325 Revised 03/20/2009 ii Copyright 2008 by Wavelink Corporation All rights reserved. Wavelink Corporation 6985 South Union Park Avenue, Suite 335 Midvale,

More information

Reporting for Contact Center Setup and Operations Guide. BCM Contact Center

Reporting for Contact Center Setup and Operations Guide. BCM Contact Center Reporting for Contact Center Setup and Operations Guide BCM Contact Center Document Number: NN40040-302 Document Status: Standard Document Version: 04.00 Part Code: N0060637 Date: June 2006 Copyright 2005

More information

Bitrix Site Manager ASP.NET. Installation Guide

Bitrix Site Manager ASP.NET. Installation Guide Bitrix Site Manager ASP.NET Installation Guide Contents Introduction... 4 Chapter 1. Checking for IIS Installation... 5 Chapter 2. Using An Archive File to Install Bitrix Site Manager ASP.NET... 7 Preliminary

More information

Version 3.8. Installation Guide

Version 3.8. Installation Guide Version 3.8 Installation Guide Copyright 2007 Jetro Platforms, Ltd. All rights reserved. This document is being furnished by Jetro Platforms for information purposes only to licensed users of the Jetro

More information

SyncThru TM Web Admin Service Administrator Manual

SyncThru TM Web Admin Service Administrator Manual SyncThru TM Web Admin Service Administrator Manual 2007 Samsung Electronics Co., Ltd. All rights reserved. This administrator's guide is provided for information purposes only. All information included

More information

RSA Authentication Manager 7.1 Basic Exercises

RSA Authentication Manager 7.1 Basic Exercises RSA Authentication Manager 7.1 Basic Exercises Contact Information Go to the RSA corporate web site for regional Customer Support telephone and fax numbers: www.rsa.com Trademarks RSA and the RSA logo

More information

Archive Attender Version 3.5

Archive Attender Version 3.5 Archive Attender Version 3.5 Getting Started Guide Sherpa Software (800) 255-5155 www.sherpasoftware.com Page 1 Under the copyright laws, neither the documentation nor the software can be copied, photocopied,

More information

Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.

Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements. ServerView User s Guide (For Windows Agent) Areas Covered - Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview of ServerView

More information

HP IMC Firewall Manager

HP IMC Firewall Manager HP IMC Firewall Manager Configuration Guide Part number: 5998-2267 Document version: 6PW102-20120420 Legal and notice information Copyright 2012 Hewlett-Packard Development Company, L.P. No part of this

More information

CTERA Agent for Mac OS-X

CTERA Agent for Mac OS-X User Guide CTERA Agent for Mac OS-X September 2013 Version 4.0 Copyright 2009-2013 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without

More information

Upgrading from Call Center Reporting to Reporting for Contact Center. BCM Contact Center

Upgrading from Call Center Reporting to Reporting for Contact Center. BCM Contact Center Upgrading from Call Center Reporting to Reporting for Contact Center BCM Contact Center Document Number: NN40010-400 Document Status: Standard Document Version: 02.00 Date: June 2006 Copyright Nortel Networks

More information

RSM Web Gateway RSM Web Client INSTALLATION AND ADMINISTRATION GUIDE

RSM Web Gateway RSM Web Client INSTALLATION AND ADMINISTRATION GUIDE RSM Web Gateway RSM Web Client INSTALLATION AND ADMINISTRATION GUIDE Installation and Administration Guide RSM Web Client and RSM Web Gateway 17 August, 2004 Page 1 Copyright Notice 2004 Sony Corporation.

More information

Pro-Watch Software Suite Installation Guide. 2013 Honeywell Release 4.1

Pro-Watch Software Suite Installation Guide. 2013 Honeywell Release 4.1 Pro-Watch Software Suite Release 4.1 Installation Guide Document 7-901073V2 Pro-Watch Software Suite Installation Guide 2013 Honeywell Release 4.1 Copyright 2013 Honeywell. All rights reserved. Pro-Watch

More information

Evoko Room Manager. System Administrator s Guide and Manual

Evoko Room Manager. System Administrator s Guide and Manual Evoko Room Manager System Administrator s Guide and Manual 1 1. Contents 1. Contents... 2 2. Read this first! Introduction to this Guide... 6 3. User Guide... 6 4. System Architecture Overview... 8 ----

More information

Installing SQL-Ledger on Windows

Installing SQL-Ledger on Windows Installing SQL-Ledger on Windows Requirements Windows 2000, Windows XP, Windows Server 2000 or Windows Server 2003 WinZip Knowledge of simple DOS commands, i.e. CD, DIR, MKDIR, COPY, REN Steps Installing

More information

Sophos for Microsoft SharePoint startup guide

Sophos for Microsoft SharePoint startup guide Sophos for Microsoft SharePoint startup guide Product version: 2.0 Document date: March 2011 Contents 1 About this guide...3 2 About Sophos for Microsoft SharePoint...3 3 System requirements...3 4 Planning

More information

DSView 4 Management Software Transition Technical Bulletin

DSView 4 Management Software Transition Technical Bulletin DSView 4 Management Software Transition Technical Bulletin DSView, Avocent and the Avocent logo are trademarks or registered trademarks of Avocent Corporation or its affiliates in the U.S. and other countries.

More information

How To Backup Your Computer With A Remote Drive Client On A Pc Or Macbook Or Macintosh (For Macintosh) On A Macbook (For Pc Or Ipa) On An Uniden (For Ipa Or Mac Macbook) On

How To Backup Your Computer With A Remote Drive Client On A Pc Or Macbook Or Macintosh (For Macintosh) On A Macbook (For Pc Or Ipa) On An Uniden (For Ipa Or Mac Macbook) On Remote Drive PC Client software User Guide -Page 1 of 27- PRIVACY, SECURITY AND PROPRIETARY RIGHTS NOTICE: The Remote Drive PC Client software is third party software that you can use to upload your files

More information

OrgPublisher EChart Server Setup Guide

OrgPublisher EChart Server Setup Guide Table of Contents Table of Contents Introduction... 3 Role Requirements for Installation... 3 Prerequisites for Installation... 3 About OrgPublisher ECharts... 3 About EChart Rich Client Publishing...

More information

CentreWare Internet Services Setup and User Guide. Version 2.0

CentreWare Internet Services Setup and User Guide. Version 2.0 CentreWare Internet Services Setup and User Guide Version 2.0 Xerox Corporation Copyright 1999 by Xerox Corporation. All rights reserved. XEROX, The Document Company, the digital X logo, CentreWare, and

More information

How To Set Up Total Recall Web On A Microsoft Memorybook 2.5.2.2 (For A Microtron)

How To Set Up Total Recall Web On A Microsoft Memorybook 2.5.2.2 (For A Microtron) Total Recall Web Web Module Manual and Customer Quick Reference Guides COPYRIGHT NOTICE Copyright 1994-2009 by DHS Associates, Inc. All Rights Reserved. All TOTAL RECALL, TOTAL RECALL SQL, TOTAL RECALL

More information

How To Set Up A Backupassist For An Raspberry Netbook With A Data Host On A Nsync Server On A Usb 2 (Qnap) On A Netbook (Qnet) On An Usb 2 On A Cdnap (

How To Set Up A Backupassist For An Raspberry Netbook With A Data Host On A Nsync Server On A Usb 2 (Qnap) On A Netbook (Qnet) On An Usb 2 On A Cdnap ( WHITEPAPER BackupAssist Version 5.1 www.backupassist.com Cortex I.T. Labs 2001-2008 2 Contents Introduction... 3 Hardware Setup Instructions... 3 QNAP TS-409... 3 Netgear ReadyNas NV+... 5 Drobo rev1...

More information

Getting started. Symantec AntiVirus Corporate Edition. About Symantec AntiVirus. How to get started

Getting started. Symantec AntiVirus Corporate Edition. About Symantec AntiVirus. How to get started Getting started Corporate Edition Copyright 2005 Corporation. All rights reserved. Printed in the U.S.A. 03/05 PN: 10362873 and the logo are U.S. registered trademarks of Corporation. is a trademark of

More information

FileMaker Server 12. FileMaker Server Help

FileMaker Server 12. FileMaker Server Help FileMaker Server 12 FileMaker Server Help 2010-2012 FileMaker, Inc. All Rights Reserved. FileMaker, Inc. 5201 Patrick Henry Drive Santa Clara, California 95054 FileMaker is a trademark of FileMaker, Inc.

More information

POLICY PATROL MFT. Manual

POLICY PATROL MFT. Manual POLICY PATROL MFT Manual MANUAL Policy Patrol MFT This manual, and the software described in this manual, are copyrighted. No part of this manual or the described software may be copied, reproduced, translated

More information

CTERA Agent for Linux

CTERA Agent for Linux User Guide CTERA Agent for Linux September 2013 Version 4.0 Copyright 2009-2013 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without written

More information

Users Guide. SelenioFlex File. Version 2.10.0

Users Guide. SelenioFlex File. Version 2.10.0 SelenioFlex File Version 2.10.0 August 2015 Publication Information 2015 Imagine Communications Corp. Proprietary and Confidential. Imagine Communications considers this document and its contents to be

More information

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...

More information

Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting

Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting Features Reference About Unified Communication System Before Using This Machine Starting a Meeting What You Can Do During the Meeting Leaving a Meeting Managing Address Book Changing Network Configuration

More information

System Administration and Log Management

System Administration and Log Management CHAPTER 6 System Overview System Administration and Log Management Users must have sufficient access rights, or permission levels, to perform any operations on network elements (the devices, such as routers,

More information

CentreWare Management Pack for System Center Operations Manager User Guide Version 1.8

CentreWare Management Pack for System Center Operations Manager User Guide Version 1.8 CentreWare Management Pack for System Center Operations Manager User Guide Version 1.8 CentreWare Management Pack for System Center Operations Manager 1 September 9, 2008 2008 XEROX CORPORATION. All rights

More information