NUDURA Product Guide. Building Has Evolved.
|
|
|
- Stephany Blankenship
- 10 years ago
- Views:
Transcription
1 NUDURA Product Guide Building Has Evolved.
2
3 TABLE OF CONTENTS Introduction 4 Product Innovation 5 Product Lines 6 NUDURA ICF Series Assembled Forms: Standard Form 7 90 Form 8 45 Form 9 Taper Top Form 10 Brick Ledge Form 11 T-Form Radius Form 14 Unassembled Forms: Standard Form 15 Taper Top Form 16 Double Sided Taper Top Form 17 Brick Ledge Form 18 Double Sided Brick Ledge Form 19 Brick Ledge & Taper Top Form 20 Optimizer Form 21 One Series Plus Series NUDURA Plus Forms 24 R-Value Inserts 25 Integrated Series HydroFoam 26 RetroFit 27 Ceiling Technology 28 Floor Technology 28 NUDURA Form Accessories 29 NUDURA Accessories NUDURA Alignment System NUDURA Tall Wall Adapter Kit 37 Customer Service
4 Introduction CMTA Engineering Consultants Designed for Optimal Performance Innovation Makes a Difference Energy Efficient Building Envelope Superior Customer Service Training & Technical Support Buildings today demand reliable, energy efficient, eco-friendly building envelopes that provide superior performance benefits to minimize energy costs, reduce carbon emissions, and maximize property value. NUDURA structures offer superior strength, storm, sound, and fire resistance, and are why the design community, developers, and contractors across the world continue to choose NUDURA s Integrated Building Technology as a proven alternative to traditional building methods. Our Insulated Concrete Forms provide design professionals, architects, home owners and contractors the freedom and versatility to design and build a structure the way it was envisioned. Building with NUDURA gives you the opportunity to build faster and more efficient, while offering your clients an eco-friendly structure with substantial benefits that contribute to long-term energy savings. When specifying NUDURA you can assure your customers that you are using the best building solution available today nudura.com Building Has Evolved.
5 Product Innovation Architect: Nathalie Tremblay NUDURA forms are manufactured with industry leading patented technologies that are exclusive to NUDURA, offering you a full line of innovative products designed to provide superior energy efficiency, greater strength, and sound resistance. Our building envelope provides an affordable eco-friendly building solution that allows you to build faster, more efficiently and offers substantial benefits over traditional construction. Innovation makes us the solution to better building. DURALOK Technology - Securely locks forms into place with a triple tooth interlock eliminating the need to wire or glue forms, resulting in reduced labor costs during installation. Once the forms are stacked together a continuous full height-fastening strip ensures wall heights are always accurate, compared to other forms without full height-fastening which can cause wall height shrinkage once concrete is placed. DURALOK makes NUDURA the strongest in the industry. DURAFOLD Technology - Patented hinged web technology allows the entire NUDURA form line up to fold and ship flat, allowing for 40% more product on a truck compared to other Insulated Concrete Form products. Once on-site, simply unfold and stack. DURAMAX Technology - Largest standard form on the market measuring x 18 (2438 x 457 mm). Our form creates 60% fewer joints in the wall compared to other wall systems and allows installers the ability to place 12 sq.ft. (1.11m2) of wall area with one block. 4-WAY REVERSIBLE System - Patented foam interlock allows the form to be 4 way reversible, eliminating left and right corners, which helps speed up the building process and reduces product waste on-site. 5 Watch our Innovation Video 5
6 Product Series The NUDURA ICF Series is the leader in Insulated Concrete Form Innovation and technology and offers users the ability to combine a variety of products during the building process. The NUDURA ICF Series offers unique advantages over other products currently on the market. DURAMAX Technology DURAFOLD Technology DURALOK Technology The 4-Way Reversible System The One Series is the industry s only multi-link form system that enables the creation of a fully exposed concrete surface that extends to the face of a standard NUDURA form panel. This offers builders and architects unmatched versatility for projects designed to use ICFs. At the core of this innovative line is our DURA MULTILINK Technology, a newly designed web that enables the builder to create custom multi-sided form combinations for a variety of commercial and residential building projects. The Plus Series product line introduces an innovative way for designers and engineers to build their own R-value. Comprised of two new products, the Plus Form and the R-Value Plus+ insert, this product line offers the ability to optimize R-Value with thermal mass to provide significant energy savings for building owners. The NUDURA Plus Series allows professionals the ability to meet new installation requirements with one product. The Integrated Series from NUDURA combines building envelope products that work in conjunction with our line of Insulated Concrete Forms to provide maximum energy efficiency. Each Integrated Series product has been manufactured to install quickly and efficiently and replaces many traditional forms of insulation products that are far more labor intensive. 6
7 Standard Form Unit - Assembled A Close view of folding metal-hinged web MAY WE SUGGEST: FORM-LOCK Assembled Product Shown Above Used to maintain wall straightness. Other uses include wall alignment for vertical stack joints. Length Width A 9 ¼ (235mm) 11 ¼ (286mm) 13 ¼ (337mm) 15 ¼ (387mm) 17 ¼ (438mm) Height 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) EPS Thickness 2 5 /8 (67mm) 2 5 /8 (67mm) 2 5 /8 (67mm) 2 5 /8 (67mm) 2 5 /8 (67mm) Available for 6 (150mm), 8 (200mm), 10 (250mm), 12 (300mm) Standard Forms. Core Width 6 (150mm) 8 (200mm) 10 (250mm) 12 (300mm) Qty./Bundle Units come assembled with folding, metal-hinged webs. Length 10 (3m) 10 (3m) 10 (3m) 10 (3m) Qty./Bundle 10 pcs 10 pcs 10 pcs 10 pcs BLOK06 BLOK08 BLOK10 BLOK12 7 Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. Refer to pages for related product accessories & tools. For additional information visit nudura.com or call Webs are included with assembled forms. 7
8 90 Form Unit - Assembled View of folding metal-hinged web and insert web for angled corner (included in order). Assembled Product Shown Above MAY WE SUGGEST: Vertical Joint Clip 8 5/8 (219mm) Vertical Joint Clip This metal clip is designed to connect the form together at the vertical joints. It replaces having to tie wire or tape forms together while providing a solid connection using minimal amount of labor to install. Length A 31 5 /8 (803mm) 31 5 /8 (803mm) 33 5 /8 (854mm) 33 5 /8 (854mm) 37 5 /8 (956mm) Length B 15 5 /8 (397mm) 15 5 /8 (397mm) 17 5 /8 (448mm) 19 5 /8 (498mm) 21 5 /8 (549mm) Width C 9 ¼ (235mm) 11 ¼ (286mm) 13 ¼ (337mm) 15 ¼ (387mm) 17 ¼ (438mm) Height 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) Qty./Bundle Qty./Box 200 VJC Units come assembled with folding, metal-hinged webs. 88 Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. Refer to pages for related product accessories & tools. For additional information visit nudura.com or call Webs are included with assembled forms.
9 45 Form Unit - Assembled View of folding metal-hinged web and insert web for angled corner (included in order). MAY WE SUGGEST: Vertical Joint Clip Assembled Product Shown Above 8 5/8 (219mm) Vertical Joint Clip This metal clip is designed to connect the form together at the vertical joints. It replaces having to tie wire or tape forms together while providing a solid connection using minimal amount of labor to install. Length A 26 ½ (673mm) 26 ½ (673mm) 26 ½ (673mm) 28 ½ (724mm) 30 ½ (775mm) Length B 10 ½ (267mm) 10 ½ (267mm) 10 ½ (267mm) 12 ½ (318mm) 14 ½ (368mm) Width C 9 ¼ (235mm) 11 ¼ (286mm) 13 ¼ (337mm) 15 ¼ (387mm) 17 ¼ (438mm) Height 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) Qty./Bundle Units come assembled with folding, metal-hinged webs. Qty./Box 200 VJC 9 Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. Refer to pages for related product accessories & tools. For additional information visit nudura.com or call Webs are included with assembled forms. 9
10 Taper Top Form Unit - Assembled Close view of folding metal-hinged web Assembled Product Shown Above MAY WE SUGGEST: Heavy Duty Tape 4 Heavy Duty Tape - 4 x 260 (96 mm x 66 m) Used for covering the interlock at the top of a wall to protect it from concrete getting into the sockets. Can also be used as an air barrier tape. Assembled (2438 mm) One-Sided Taper Top Shown Above Width A 11 ¼ (268mm) 13 ¼ (337mm) Height 18 (457mm) 18 (457mm) Length - Qty./Bundle 6 6 Qty./Box 24 TAP4HD TT-6 TT-8 Webs are included with assembled units Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. Refer to pages for related product accessories & tools. For additional information visit nudura.com or call Length - Qty./Bundle 3 3 TT96-6 TT96-8 Webs are included with assembled units. Units come assembled with folding, metal-hinged webs. Units come assembled with folding, insert webs. Only available as an un-assembled Form Unit. Refer to page 16 for order information.
11 Brick Ledge Form Unit - Assembled Close view of folding metal-hinged web Assembled Product Shown Above MAY WE SUGGEST: Brick Ledge Extension Brick Ledge Extension Used for supporting standard brick or stone veneer finishes, when constructing brick ledges at corners, and can be installed to meet any elevation change or slope. Assembled (2438 mm) Molded Brick Ledge Shown Above Width A 11 ¼ (268mm) 13 ¼ (337mm) Height 15 ¾ (400mm) 17 ¾ (451mm) Length - Qty./Bundle 4 4 BRI-6 BRI-6 Webs are included with assembled units. Length - Qty./Bundle 14 Qty./Bundle 2 2 BRICK BR96-6 BR96-8 Refer to page 20 for more order information. Webs are included with assembled units. 11 Refer to pages for related product accessories & tools. For additional information visit nudura.com or call Units come assembled with folding, metal-hinged webs. Units come assembled with folding, insert webs. Only available as an un-assembled Form Unit. Refer to page 18 for order info. 11
12 Short T-Form & Long T-Form Units Short T-Form Short T-Form A Long T-Form * Area/Unit Long T-Form B S-T W-6 ** T-Cross - Webs ordered separately. Close view of insert webs - Webs are included with order Webs are Included - Site Assembly Required 12 Refer to pages for related product accessories & tools. For additional information visit nudura.com or call For more form dimensions refer to NUDURA s Installation Manual.
13 Short T-Form & Long T-Form Units CORE Main Wall 4 (100mm) 6 (150mm) 8 (200mm) 10 (250mm) 12 (300mm) WIDTH Interior Wall - T 4 (100mm) Bundle Includes 4 Courses - 2 Short and 2 Long T-Forms Main Wall - represents the concrete core of the outside form Interior Wall T - represents the concrete core of the inside form that joins to the Main Wall Short T-Form Length (A) 50 (1270mm) 50 (1270mm) 50 (1270mm) 50 (1270mm) 50 (1270mm) Long T-Form Length (B) 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) Area/Unit* 11 1/2 ft 2 (1.068m 2 ) 11 1/2 ft 2 (1.068m 2 ) 11 1/2 ft 2 (1.068m 2 ) 11 1/2 ft 2 (1.068m 2 ) 11 1/2 ft 2 (1.068m 2 ) Bundle T4-M4 T4-M6 T4-M8 T4-M10 T4-M12 Interior Wall - T 6 (150mm) Short T-Form Length (A) 52 (1321mm) 52 (1321mm) 52 (1321mm) 52 (1321mm) 52 (1321mm) Long T-Form Length (B) 20 (508mm) 20 (508mm) 20 (508mm) 20 (508mm) 20 (508mm) Area/Unit* 12 ft 2 (1.115m 2 ) 12 ft 2 (1.115m 2 ) 12 ft 2 (1.115m 2 ) 12 ft 2 (1.115m 2 ) 12 ft 2 (1.115m 2 ) Bundle T6-M4 T6-M6 T6-M8 T6-M10 T6-M12 Interior Wall - T 8 (200mm) Short T-Form Length (A) 54 (1372mm) 54 (1372mm) 54 (1372mm) 54 (1372mm) 54 (1372mm) Long T-Form Length (B) 22 (559mm) 22 (559mm) 22 (559mm) 22 (559mm) 22 (559mm) Area/Unit* 12 1/2 ft 2 (1.161m 2 ) 12 1/2 ft 2 (1.161m 2 ) 12 1/2 ft 2 (1.161m 2 ) 12 1/2 ft 2 (1.161m 2 ) 12 1/2 ft 2 (1.161m 2 ) Bundle T8-M4 T8-M6 T8-M8 T8-M10 T8-M12 Interior Wall - T 10 (250mm) Short T-Form Length (A) 56 (1422mm) 56 (1422mm) 56 (1422mm) 56 (1422mm) 56 (1422mm) Long T-Form Length (B) 24 (610mm) 24 (610mm) 24 (610mm) 24 (610mm) 24 (610mm) Area/Unit* 13 ft 2 (1.208m 2 ) 13 ft 2 (1.208m 2 ) 13 ft 2 (1.208m 2 ) 13 ft 2 (1.208m 2 ) 13 ft 2 (1.208m 2 ) Bundle T10-M4 T10-M6 T10-M8 T10M10 T10M12 Interior Wall - T 12 (300mm) Short T-Form Length (A) 58 (1473mm) 58 (1473mm) 58 (1473mm) 58 (1473mm) 58 (1473mm) Long T-Form Length (B) 26 (660mm) 26 (660mm) 26 (660mm) 26 (660mm) 26 (660mm) Area/Unit* 13 1/2 ft 2 (1.254m 2 ) 13 1/2 ft 2 (1.254m 2 ) 13 1/2 ft 2 (1.254m 2 ) 13 1/2 ft 2 (1.254m 2 ) 13 1/2 ft 2 (1.254m 2 ) Bundle T12-M4 T12-M6 T12-M8 T12M10 T12M12 ** Special Order: S-TW-6: T-Cross Form Unit Unassembled - 4 panels per T-Cross (4 T-Cross Form Units per bundle) - 32 webs required per bundle. Webs ordered separately. Refer to page 15 for web order information. Short T-Form Main Exterior Wall Length. Webs are included. Long T-Form Main Exterior Wall Length. Webs are included. *Area/Unit - a unit represents one Short T-Form and one Long T-Form connected together forming 2 courses (reference photo on left)
14 Radius Form Unit Custom Ordered Close view of folding metal-hinged web MAY WE SUGGEST: Parging Mix & Fiber Mesh Assembled Product Shown Above Parging Mix and Fiber Mesh The parge mix is a dry cementitious product that is used to cover exposed EPS that is not covered by an exterior finish. Used in conjunction with Fiber Mesh. The fiber mesh gets embedded into the parge coat to give it strength. Length q Width 9 ¼ (235mm) 11 ¼ (286mm) 13 ¼ (337mm) 15 ¼ (387mm) 17 ¼ (438mm) Height 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) Radius Qty./Bundle Manufactured to Specifications. Varies with radius size. Contact your local distributor for details. RAD-4 RAD-6 RAD-8 RAD-10 RAD-12 Parging Mix Coverage - 75 sq ft (7 m 2 ) Fiber Mesh Coverage sq ft (44 m 2 ) Units come assembled with folding metal-hinged webs. Qty./Each 1 BAG Qty./Each 1 ROLL PARG MESH Refer to NUDURA s Installation Manual for the Radius Form Calculator Refer to pages for related product accessories & tools. For additional information visit nudura.com or call Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more.
15 Standard Form Unit - Unassembled CA C Close view of insert webs - available in 4-12 ( mm) sizes Insert Webs (Ordered Separately) Unassembled Product Shown Above Small Box Qty./Box WEB-4 WEB-6 WEB-8 WEB-10 WEB-12 Large Box Qty./Box WEB4 WEB6 WEB8 WEB10 WEB12 Length Width A 9 ¼ (235mm) 11 ¼ (286mm) 13 ¼ (337mm) 15 ¼ (387mm) 17 ¼ (438mm) Height 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) Qty./Bundle Includes: 6 Standard Panels Panel Panel Panel Panel Panel Web Qty. Req d/bundle Units come unassembled. Insert webs required per bundle - refer to web order chart on left. 15 Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. Refer to pages for related product accessories & tools. For additional information visit nudura.com or call
16 Taper Top Form Unit - Unassembled Close view of insert webs - available in 4-12 ( mm) sizes Unassembled Product Shown Above Insert Webs (Ordered Separately) Small Box Overall Width A 9 ¼ (235mm) 11 ¼ (286mm) 13¼ (337mm) 15 ¼ (387mm) 17 ¼ (438mm) Qty./Box Length - WEB-4 WEB-6 WEB-8 WEB-10 WEB-12 Qty./Bundle Includes: 6 Taper Top Panels & 6 Standard Panels TT-P TT-P TT-P TT-P TT-P Large Box Web Qty. Req d/bundle Qty./Box WEB4 WEB6 WEB8 WEB10 WEB12 Length - Qty./Bundle Includes: 3 Taper Top Panels & 3 Standard Panels 16 Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. Refer to pages for related product accessories & tools. For additional information visit nudura.com or call TT96-P TT96-P TT96-P TT96-P TT96-P Web Qty. Req d/bundle Units come unassembled. Insert webs required per bundle - refer to web order chart on left.
17 Double Sided Taper Top - Unassembled Close view of insert webs - available in 4-12 ( mm) sizes Unassembled Product Shown Above Insert Webs (Ordered Separately) Small Box Qty./Box WEB-4 WEB-6 WEB-8 WEB-10 WEB-12 Large Box Qty./Box WEB4 WEB6 WEB8 WEB10 WEB12 Overall Width A Overall Width B Length - Qty./Bundle 9 ¼ (235mm) 8 (203mm) 11 ¼ (286mm) 10 (254mm) 13¼ (337mm) 12 (305mm) 15 ¼ (387mm) 14 (356mm) requires two Taper Top Panels (TT-P) to assemble one double sided unit Includes: 6 Taper Top Panels & 6 Standard Panels 17 ¼ (438mm) 16 (406mm) TT-P TT-P TT-P TT-P TT-P Web Qty. Req d/bundle Length - Qty./Bundle Includes: 6 Taper Top Panels TT-D TT-D* TT-D TT-D TT-D Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. Web Qty. Req d/bundle Refer to pages for related product accessories & tools. For additional information visit nudura.com or call Units come unassembled. *Available assembled - 3 units/bundle: TD96-6 (webs included). Insert webs required per bundle - refer to web order chart on left. 17
18 Brick Ledge Form Unit - Unassembled Close view of insert webs - available in 4-12 ( mm) sizes Unassembled Product Shown Above Insert Webs (Ordered Separately) Small Box Qty./Box WEB-4 WEB-6 WEB-8 WEB-10 WEB-12 Large Box Qty./Box WEB4 WEB6 WEB8 WEB10 WEB12 Overall Width A Overall Width B 9 ¼ (235mm) 13 ¾ (349mm) 11 ¼ (286mm) 15 ¾ (400mm) 13¼ (337mm) 17 ¾ (451mm) 15 ¼ (387mm) 19 ¾ (502mm) 17 ¼ (438mm) 21 ¾ (552mm) requires one Brick Ledge Panel & one Standard Panel to assemble one form unit Length - Qty./Bundle Includes: 4 Brick Ledge Panels & 4 Standard Panels BRI-P BRI-P BRI-P BRI-P BRI-P Web Qty. Req d/bundle requires one Brick Ledge Panel & one Standard Panel to assemble one form unit Length - Qty./Bundle Includes: 2 Brick Ledge Panels & 2 Standard Panels Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. Refer to pages for related product accessories & tools. For additional information visit nudura.com or call BR96-P BR96-P BR96-P BR96-P BR96-P Web Qty. Req d/bundle Units come unassembled. Insert webs required per bundle - refer to web order chart on left.
19 Double Sided Brick Ledge - Unassembled Close view of insert webs - available in 4-12 ( mm) sizes Unassembled Product Shown Above Insert Webs (Ordered Separately) Small Box Qty./Box WEB-4 WEB-6 WEB-8 WEB-10 WEB-12 Large Box Qty./Box WEB4 WEB6 WEB8 WEB10 WEB12 Overall Width A Overall Width B Length - Qty./Bundle 9 ¼ (235mm) 18 ¼ (463mm) 11 ¼ (286mm) 20 ¼ (514mm) 13¼ (337mm) 22 ¼ (565mm) 15 ¼ (387mm) 24 ¼ (616mm) requires two Brick Ledge Panels (BRI-P) to assemble one double sided unit Includes: 4 Brick Ledge Panels & 4 Standard Panels 17 ¼ (438mm) 26 ¼ (667mm) BRI-P BRI-P BRI-P BRI-P BRI-P Web Qty. Req d/bundle Length requires two Brick Ledge Panels (BR96-P) to assemble one double sided unit Qty./Bundle Includes: 2 Brick Ledge Panels & 2 Standard Panels Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. BR96-P BR96-P BR96-P BR96-P BR96-P Web Qty. Req d/bundle Refer to pages for related product accessories & tools. For additional information visit nudura.com or call Units come unassembled. Insert webs required per bundle - refer to web order chart on left. 19
20 Brick Ledge & Taper Top - Unassembled Close view of insert webs - available in 4-12 ( mm) sizes Unassembled Product Shown Above Insert Webs (Ordered Separately) Small Box Qty./Box WEB-4 WEB-6 WEB-8 WEB-10 WEB-12 Large Box Qty./Box WEB4 WEB6 WEB8 WEB10 WEB12 Overall Width A Overall Width B 9 ¼ (235mm) 13 ¾ (349mm) 11 ¼ (286mm) 15 ¾ (400mm) 13¼ (337mm) 17 ¾ (451mm) 15 ¼ (387mm) 19 ¾ (502mm) 17 ¼ (438mm) 21 ¾ (5522mm) requires one Brick Ledge Panel (BRI-P) & one Taper Top Panel (TT-P) to assemble one unit Length - Qty./Bundle Includes: 4 Brick Ledge Panels w/ 4 Standard Panels & 6 Taper Top Panels w/ 6 Standard Panels BRI-P & TT-P BRI-P & TT-P BRI-P & TT-P BRI-P & TT-P BRI-P & TT-P Web Qty. Req d/bundle Length - Qty./Bundle requires two Brick Ledge Panels (BR96-P) to assemble one double sided unit Includes: 2 Brick Ledge Panels w/ 2 Standard Panels & 3 Taper Top Panels w/ 3 Standard Panels 20 Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. Refer to pages for related product accessories & tools. For additional information visit nudura.com or call Web Qty. Req d/bundle BR96-P & TT96-P BR96-P & TT96-P BR96-P & TT96-P BR96-P & TT96-P BR96-P & TT96-P Units come unassembled. Insert webs required per bundle - refer to web order chart on left.
21 Optimizer Form Unit - Unassembled Optimizer Close view of insert webs - available in 6-12 ( mm) sizes Insert Webs (Ordered Separately) Product Shown Assembled Above Qty./Box OWEB-6 OWEB-8 OWEB10 OWEB12 Length Overall Width A 11 ¼ (286mm) 13 ¼ (337mm) 15 ¼ (387mm) 17 ¼ (438mm) Height 12 (300mm) 12 (300mm) 12 (300mm) 12 (300mm) Qty./Bundle Includes: 12 Optimizer Panels OP-PAN OP-PAN OP-PAN OP-PAN Web Qty. Red d/bundle Units come unassembled. Insert webs required per bundle - refer to web order chart on left. 21 Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more. Refer to pages for related product accessories & tools. For additional information visit nudura.com or call
22 NUDURA One Series Forms A Multi-Form Ties Metal Jig for One Series assembly 90º Corner Panel Options 90 Corner Outside (EPS Inside Panel) 90 Corner Inside (EPS Outside Panel) B A B A 22 Note: Corner designation refers to plywood panel location. Refer to pages for related product accessories & tools. For additional information visit Nudura.com or call Visit the Resource Center on NUDURA s website (nudura.com/resource-center) for design details, BIM library, installation links & more.
23 NUDURA One Series Forms NOTE: To assemble a SINGLE One Series Form Unit you will require the following components: STANDARD 1 x Standard EPS Panel 1 x Plywood Panel 24 x Screws 12 x Multi-Form Ties 12 x Insert Webs 1 x Jig 90º CORNER INSIDE 1 x 90 Outside EPS Panel 1 x Plywood Panel 8 x Screws 4 x Multi-Form Ties 4 x Insert Webs 1 x Jig 90º CORNER OUTSIDE 1 x 90 Inside EPS Panel 1 x Plywood Panel 12 x Screws 6 x Multi-Form Ties 4 x Insert Webs 1 x Jig Plywood* Standard 90º Outside 90º Inside Length A (2438 mm) (2438 mm) 37 5/8 (956 mm) 20 3/8 (518 mm) Length B /8 (549 mm) 4 3/8 (111 mm) Height 18 (457 mm) 18 (457 mm) 18 (457 mm) 18 (457 mm) Qty/Bundle 1 Plywood Panel 6 Standard Panels 6 Panels 16 Panels Code PLYPAN PANEL 90-OUT S-TW-6 Web Qty Req/Bundle Unassembled 45 Inside and Outside Panels available through special order only * Plywood panels must be cut on-site. Refer to brochure for instructions. Hex Head Screw with Steel Flat Washer Size: #10 x 2.0 (50 mm) Qty./Pail: 1000 Code: SC-2.0 (Minimum 2 (50 mm) screws must be used SC-2.0) Multi-Form Ties Qty./Box: 96 pieces Jig Code: MULTI Metal Jig for One-Series Form assembly Qty: 1 Jig Code: ONEJIG Insert Webs (Ordered Separately) Small Box Qty./Box Corner Connector The corner connector is designed to securely connect two panels of plypan together at a 90 corner. Length: 10 (3 m) Code: ONECB WEB-4 WEB-6 WEB-8 WEB-10 WEB-12 Large Box Qty./Box WEB4 WEB6 WEB8 WEB10 WEB12 Full length of connector not shown. For additional information visit nudura.com or call
24 NUDURA Plus+ Forms A D B C A Standard Form Unit (Type 2 EPS Laminate on one side) Thickness 1 (25 mm) 2 (50 mm) 4 (100 mm) 6 (150 mm) Length (2438 mm) (2438 mm) (2438 mm) (2438 mm) Height 18 (457 mm) 18 (457 mm) 18 (457 mm) 18 (457 mm) Qty./Bundle Code 96-6P1 96-6P2 96-6P4 96-6P6 *Other form units & core thicknesses available through special request. 90º Form Unit - Outside (Long Side) (Type 2 EPS Laminate on one side) Thickness 1 (25 mm) 2 (50 mm) 4 (100 mm) 6 (150 mm) Length A Core Width 32 5/8 (8134 mm) (100mm) 33 5/8 6 (854 (150mm) 358 5/8 (200mm) ( (250mm) 5/8 (956 mm) 12 (300mm) Length B 16 5/8 (422 mm) 17 5/8 (448 mm) 19 5/8 (498 mm) 21 5/8 (550 mm) Height 18 (457 mm) 18 (457 mm) 18 (457 mm) 18 (457 mm) Qty./Bundle Code 906P1L 906P2L 906P4L 906P6L 90º Form Unit - Inside (Short Side) (Type 2 EPS Laminate on one side) Thickness 1 (25 mm) 2 (50 mm) 4 (100 mm) 6 (150 mm) Length C 19 3/8 (492 mm) 18 3/8 (467 mm) 16 3/8 (416 mm) 14 3/8 (365 mm) Length D 3 3/8 (86 mm) 2 3/8 (60 mm) 3/8 (10 mm) ** 1 Size (25 Size - mm) 1-1 R-value (502 mm) 2 R-value R-value ( mm) R-value R-value ( mm) R-value R-value Height 18 (457 mm) 18 (457 mm) 18 (457 mm) 18 (457 mm) Qty./Bundle Refer to pages for related product accessories & tools. For additional information visit Nudura.com or call Code 906P1S 906P2S 906P4S 906P6S **On-site notching of EPS foam required.
25 R-Value Inserts 2 (50 mm) R-value (100 mm) R-value (150 mm) R-value - 47 Build your own R-Value 6 (150 mm) concrete core R-Value ratings based on exterior brick finish The NUDURA R-Value Inserts allow the ability to customize the desired amount of insulation needed to meet the specific requirements of any project. The inserts are available in 3 standard sizes: 2 (50 mm), 4 (10 mm) and 6 (150 mm). Custom combinations can be created to provide further insulation value if desired and are compatible with all sizes of forms offered by NUDURA, with core sizes ranging from 4 (100 mm) to 12 (300 mm). NUDURA Plus Series R-Value Inserts (EPS Foam Billet) Thickness 2 (50 mm) 4 (100 mm) 6 (150 mm) Width 7 1/2 (190 mm) 7 1/2 (190 mm) 7 1/2 (190 mm) Height 32 (812 mm) 32 (812 mm) 32 (812 mm) Qty/Bundle Code INS-2 INS-4 INS-6 25 Refer to pages for related product accessories & tools. For additional information visit Nudura.com or call
26 HYDROFOAM - Radiant Heat Insulation Product Highlights: The easy insulation for radiant heat. HYDROFOAM is the ideal radiant floor insulation product for residential and commercial construction projects that increases comfort and energy efficiency. HYDROFOAM maximizes radiant floor heating by ensuring the heat is dispersed evenly throughout the entire floor area, providing building occupants with a comfortable living and working environment. HYDROFOAM offers installers a lightweight high density expanded polystyrene (EPS) product that increases installation speeds, is easily cut to meet any angle or radius while providing up to R-16 insulation value. Installation is fast and easy compared to traditional foam insulation. The 4 x 4 (1.2 m x 1.2 m) boards, available in two thickness, are easily installed with an overlapping interlock on all four sides, ensuring the boards are locked in place during installation. HYDROFOAM utilizes a 360 multidirectional friction fit anchor system that eliminates the need for wire mesh. Radiant heat piping is easily stepped into place in any direction required. Insulation under the concrete slab 4 x 4 (1.2 m x 1.2 m) molded boards Only 4 (100mm) from base to nubs Available thicknesses: 2½ (64 mm) - R10 (RSI 1.76) As a special order: 4 (100mm) - R16 (RSI 2.47) Multi-directional anchoring for ½ (13 mm) pipes Shiplap/interlocking on all 4 sides Eco-friendly. No CFC s or HCFC s 100% recyclable Resistant to water and moisture Can contribute to points under LEED NC programs Approximately 1500 li. ft. (457 m) of pipe can be placed in 45 minutes when using HYDROFOAM Each board covers 16 sq. ft. (1.49 m 2 ) of surface For more information download our Technical Data Sheet on nudura.com Watch our HYDROFOAM Installation Video. 26 Sheet Thickness 2 1/2 (64 mm) 4 ( 100 mm) Sheet Size 4 x 4 (1.2 m x 1.2 m) 4 x 4 (1.2 m x 1.2 m) Qty./Bundle 10 6 RHFL RHFL-4
27 RetroFit - Insulation Technology Easy Installation. Superior Performance. NUDURA RetroFit Insulation Technology is an easy to-use insulation solution for finishing basements or insulating interior or exterior block walls. Installation is fast and effortless, compared to conventional multi-step finishing methods. The NUDURA RetroFit Insulation Technology insulates and creates fastening points in one simple step. Simply attach NUDURA s standard 4 x 8 (1.2 m x 2.4 m) sheets to the wall using the embedded fastening strip and a concrete screw. NUDURA RetroFit Insulation Technology panels fit seamlessly together with a shiplap system, electrical installation is easily completed, and drywall or Gypsum Board is attached using the 2 ½ (64 mm) fastening strip located on 16 (400 mm) centers. When installed, NUDURA RetroFit Insulation Technology provides insulation performance ratings up to R-14.8 resulting in greater energy efficiency and comfort to any home or commercial structure. Product Highlights: Provides up to R-14.8 of insulation Moisture resistant No VOC s, CFC s or HCFC s Available in 4 x 8 (1.2 m x 2.4 m) sheets and thicknesses of 2 5 /8 (67 mm), 3 ½ (89 mm), 3 7 /8 (98 mm) Performance ratings up to R-14.8 (RSI 2.61 & U-Value w/m 2 k) Available with wood or polystyrene fastening strips Made of EPS (Expanded Polystyrene) making it lightweight and easy to cut Simple to install with embedded 2 ½ (64 mm) fastening strip located on 16 (400 mm) centers Panels easily fit together with a shiplap system to eliminate thermal bridging Insulation for basement walls or interior, exterior block walls For more information download our Technical Data Sheet on nudura.com Watch our RetroFit Installation Video. Sheet Thickness 2 5/8 (67 mm) 3 1/2 (89 mm) 3 7/8 (98 mm) Sheet Size x (1219 x 2438mm) x (1219 x 2438mm) x (1219 x 2438mm) Qty./Bundle Strapping Wood Polystyrene Wood Polystyrene Wood Polystyrene P9-050 P9-055 P9-040 P9-045 P9-031 P (127 mm) Concrete Screws Qty./Pail: 300 screws Qty./Jar: 50 screws SC-CSL SC-CS 27
28 Ceiling and Floor Technology NUDURA Ceiling Technology Sheet Thickness 2 5/8 (67 mm) 3 1/2 (89 mm) 3 7/8 (98 mm) Sheet Size x (1219 x 2438mm) x (1219 x 2438mm) x (1219 x 2438mm) Wood Strapping Yes Yes Yes Qty./Bundle P9-050 P9-040 P9-031 Product Highlights: Reduces air infiltration efficiently. Water and humidity resistant. Used in a double layer, it further reduces thermal bridging, increasing energy efficiency and comfort. Superior performance & user friendly. Eco-friendly Expanded Polystyrene (EPS) - does not contain CFC s or HCFC s. 100% recyclable. Embedded wood or high impact polytsyrene (limted quanitites aviailable) fastening strips. NUDURA Floor Technology #10 Screws 4 (102 mm) 5 (127 mm) Qty./Box SC-4.0 SC-5.0 Type 1- Blue 1 1/4 (32 mm) Overlap 1 7/8 (48 mm) T&G 2 1/2 (64 mm) T&G Size 24 x (610x2438mm) 24 x (610x2438mm) 24 x (610x2438mm) Qty./Bundle P1-470 P1-471 P1-472 Type 2 - Green 1 1/4 (32 mm) Overlap 1 7/8 (48 mm) T&G 2 1/2 (64 mm) T&G Size 24 x (610x2438mm) 24 x (610x2438mm) 24 x (610x2438mm) Qty./Bundle P2-435 P2-445 P2-455 Type 3 - White N/A 1 7/8 (48 mm) T&G 2 1/2 (64 mm) T&G Size - 24 x (610x2438mm) 24 x (610x2438mm) Qty./Bundle P3-443 P3-453 The floor of a building is often the most ignored surface when it comes to insulation. With changing energy codes, under slab insulation is becoming mandatory for code compliance in some regions. Complete the building envelope and insulate with NUDURA Floor Technology for increased comfort and energy efficiency. Product Highlights: A cost effective layer of protection against heat transfer to the ground. An effective base for radiant floor heating. Expanded Polystyrene (EPS) does not contain CFC s or HCFC s - 100% recyclable. 28
29 NUDURA Form Accessories Brick Ledge Extension & 6 (152mm) Screw & Washer Kit Length Width 32 (813mm) 4 1/2 (114mm) Height 13 (330mm) Qty./Bundle 14 BRICK Brick Ledge Extensions are used for supporting standard brick or stone veneer finishes, when constructing brick ledges at corners, and can be installed to meet any elevation change or slope. 6 (152mm) Screw & Washer Kit Qty./Box: 150 screws/150 washers SC-WA Screw & Washer Kit to be used to attach the Brick Ledge Extension to the form wall or to attach additional foam panels for increased insulation to a building. End Cap (with Fastening Strip) Width 4 (100mm) 6 (150mm) 8 (200mm) 10 (250mm) 12 (300mm) Height 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) 18 (457mm) EPS Thickness 2 5/8 (67mm) 2 5/8 (67mm) 2 5/8 (67mm) 2 5/8 (67mm) 2 5/8 (67mm) Qty./Box ECF-4 ECF-6 ECF-8 ECF10 ECF12 End Cap (with Fastening Strip) can be used to terminate a wall. It can also be used as a buck material for windows. Height Adjuster (with Fastening Strip) & Height Adjuster Tie Length 32 (813mm) The Height Adjuster (with Fastening Strip) combined with the Height Adjuster Tie can increase the height of Height 3 (76mm) a wall by 3 (75mm) increments. The Height Adjuster ties Qty./Bundle 80 allow the foam panels to be connected together. HADJ-F Site assembly required. Height Adjuster Tie One HADJ-F Bundle requires 160 Height Adjuster Ties Qty./Box HA-T-4 HA-T-6 HA-T-8 HA-T10 HA-T12 FORM-LOCK Available for 6-12 ( mm) Standard Forms only. Core Width 6 (150mm) 8 (200mm) 10 (250mm) 12 (300mm) Length 10 (3m) 10 (3m) 10 (3m) 10 (3m) Qty./Bundle 10 pcs 10 pcs 10 pcs 10 pcs BLOK06 BLOK08 BLOK10 BLOK12 Lintel/Cavity Closure Full length of FORM-LOCK not shown. FORM-LOCK is used to maintain wall straightness. Other uses include wall alignment for vertical stack joints. Each bundle has 100 (30 m) of FORM-LOCK. The Lintel Insulation Insert provides installers a product that provides insulation above and below the window to minimize thermal bridging. The NUDURA Lintel Insert is available in a standard 2 (50 mm) thickness. Qty./Box LINT04 LINT06 LINT08 LINT10 LINT12 29
30 NUDURA Accessories 4-Way Web Connector Qty./Box 100 4XWEBC The 4-Way Web Connector allows two or more insert webs to be connected together and used with the panel system to create wider form sizes. It also can be used to create forms of different shapes and sizes. Increased design flexibility. A ICF Connector (Formally; Multi Purpose Anchor Hanger System) A. ICF Hanger Insert Plate B. Stamped Bearing Bracket ( # 12 Screws Incl. - Box of 170) Qty./Box 50 ICFHIP Qty./Box 25 ICFSBB B ICF Connectors are used for connecting wood floor joists or for a wood roof connection system. An inexpensive, yet labor friendly connection system. 45 ICF Connector Insert Hanger Plate 1 1/4 (32 mm) x 3 1/2 (89 mm) Qty./Box 20 HIP-45 Retrofit Bracket # 12 Screws Incl. - Box of 170 The 45 ICF Connector Insert Hanger Plate is the same as the standard ICF-Connector but gives a solid floor connection for inside 90 corners as well as 45 corner connections. The 45 ICF Connector Insert Hanger Plate is used in conjunction with the Stamped Bearing Bracket Qty./Box 12 ICFRFB Lag Bolts not included. The Retrofit Bracket is used in conjunction with the Stamped Bearing Bracket as an afterthought for attachment to the concrete. This corrects mistakes made from improper installation of the ICF Connector. Transition Bracket Qty./Box 100 TRA-BR The Transition Bracket allows two different form widths to be connected together. Primary use is to create a ledge to support brick or a floor system. 30
31 NUDURA Accessories 8 5/8 (219 mm) Vertical Joint Clip Qty./Box 200 VJC The Vertical Joint Clip is designed to connect the form together at the vertical joints. It replaces having to tie wire or tape forms together while providing a solid connection using minimal amount of labor to install. Hex Head Screw with Steel Flat Washer Size # 10 x 2 (50mm) # 10 x 2.5 (64mm) # 10 x 3 (76mm) Qty./Box SC-2.0 SC-2.5 SC-3.0 Product may be different then shown. Product subject to change. The #10 screw can be used to connect the NUDURA Alignment System to the forms. Other uses include attachment of strapping or buck material to concrete. Available in 2 (50 mm), 2 1/2 (64 mm), and 3 (76 mm) lengths. Two 1/4 (6 mm) nut drivers included per pail. 10 Piece Bit Kit Contact your local distributor for more information on how to order. Ten piece kits include five ¼ magnetic nutsetters which can be used with any of NUDURA s Hex Head Screws with Steel Flat Washers, as well as five #2 red square driver bits. The durable plastic case keeps all the bits together in one convenient spot and limits trying to find drivers bits on site during construction. V-Clip Qty./Box 250 VCLIP The V-Clip is used to connect a NUDURA panel to a concrete floor. It allows the contractor to support the panel without additional materials used on the outside of the wall. Easy Buck - 10 (3 m) Long Qty./Bundle 10 pcs WBUCK The Easy Buck is used for window and door jams and allows nominal sized lumber to fit between the Expanded Polystyrene (EPS) panels. Primary uses are for doors and windows. Each bundle contains 100 (30 m) of Easy Buck. 31
32 NUDURA Accessories Brick Ties (Galvanized Steel) Brick Ties (Stainless Steel) Qty. /Box 100 pieces Qty./Box 100 pieces BRKTG BRKTSS Cast-In Place Brick Tie and Pintle. Enables solid anchorage of veneer masonry through exterior foam to concrete core; tested to meet ASTM D754 (USA) and CSA-A370 (CAN) std. requirements for masonry anchors. A Surface Mount Ties (A) Qty. /Box 100 pieces Pintle (B) Qty. /Box 100 pieces B SBRKTG PINTLE Surface Mount Tie and Pintle. Designed to be fastened with 2 NUDURA Hex head Screws anywhere on the NUDURA fastening strip. This tie will accept NUDURA Pintels and other smaller dimension pintels. Fiber Tape - 1 x 200 (24 mm x 55 m) Qty./Box 36 TAPE Fiber Tape is used to provide additional EPS support for field cut forms that have more than 4 (100mm) of EPS extending past the last web, brick ledge forms in corner conditions, and radius panel. 4 Protective Tape - 4 x 260 (96 mm x 66 m) Qty./Box 18 TAPE-4 The 4 Protective Tape is used for covering the interlock at the top of a wall to prevent concrete from flowing into the sockets. Protective Tape can also be used as an air barrier tape. 4 Heavy Duty Tape - 4 x 260 (96mm x 66m) Qty./Box 24 TAP4HD The 4 Heavy Duty Tape is used for covering the interlock at the top of a wall to prevent concrete from flowing into the sockets. Heavy Duty Tape can also be used as an air barrier tape. 32
33 NUDURA Accessories Parging Mix - Coverage of 75 sq ft (7 m 2 ) Qty. 1 BAG PARG The parge mix is a dry cementitious product that is used to cover exposed EPS that is not covered by an exterior finish. Used in conjunction with Fiber Mesh. Fiber Mesh - Coverage of 475 sq ft (44 m 2 ) Qty. 1 ROLL MESH The fiber mesh gets embedded into the parge coat to give it strength. NUDURA Low Expansion Foam - 24oz (680g) Qty./Box 12 FOAM The Low Expansion Foam is compatible with NUDURA s Expanded Polystyrene (EPS) foam and can be used for a number of different tasks on site including foaming the forms to the slab or footing, between vertical joints, securing service penetrations, and as insulation around openings. A Econo Gun II (A) Foam Gun (Metal Handle) Qty. 1 GUN GUN-M Sure Shooter (B) Foam Gun (Plastic Handle) Qty. 1 GUN GUN B The Econo Gun II and Sure Shooter Foam Guns are compatible with the NUDURA Low Expansion Foam 24oz (680g) cans. The NUDURA Low Expansion Foam can be used for a number of different tasks on site. Foam Gun Cleaner - 21oz (340g) Qty./Box 12 FOAM-C The Foam Gun Cleaner is used to clean the internal chamber of the foam gun from any hardened foam. Also used on the external surfaces for cleaning the guns. 33
34 NUDURA Accessories Waterproofing Membrane sq ft (21m 2 ) A. Summer Grade B. Winter Grade Qty. 1 ROLL WPROF Qty. 1 ROLL WPROF2 The Peel & Stick Waterproofing Membrane is used for below grade damp proofing of the NUDURA walls. Other uses for the Waterproofing Membrane include drain flashings around window and door openings and brick ledge through wall flashings. Membrane Primer Qty. 1 PAIL WPRIME The Membrane Primer is designed for use with NUDURA s self-adhesive waterproof membranes. This polymer emulsion-based primer is available in a 19L (5 gallon) pail, with a coverage of approximately ft² (60-190m²) of wall area per pail. The NUDURA Membrane primer can help improve adhesion of NUDURA s Waterproofing Membrane in specific areas. Rebar Bender Cutter Qty. 1 Bender/Cutter RBC The Rebar Bender Cutter is used for cutting and bending reinforcing steel used in the NUDURA wall system. Comes with two cutting heads that will cut up to #5 (15M) reinforcing steel. The rollers used for bending the steel are capable of handling up to a #5 (15M) bar. For more information and to watch a video on NUDURAs various accessories go to nudura.com/accessoryvideos. 34 By Preventol is an imidacloprid based Termite Insecticide Treatment that can be added at the manufacturing stage to any NUDURA ICF products. Preventol is formally evaluated by the ICC-Evaluation Service for Termite Resistance as an insect treatment designed for use in EPS Foam. (ESR-2918). (NOTE: Product option is only available from NUDURA s Southern US Plant location per USA Code Requirements.) 34
35 NUDURA Alignment System Channel Guardrail Post Forward Fall Protection Pin Toe Kick Anchor Catwalk Bracket D-Clip Turnbuckle Gravity Pin Foot Pad Diagram above illustrates both Square & Round Tube Bracing. For reference only
36 NUDURA Alignment System Square Tube Bracing - No Wall Channels Square Tube Bracing w/10 Wall Channels Includes 20 Guardrail Post 20 Catwalk Brackets 20 Turnbuckles 40 Gravity Pins BRAC-L Includes Wall Channels 20 Guardrail Post 20 Catwalk Brackets 20 Turnbuckles 40 Gravity Pins Packaged on a wooden skid. Metal Bracing Rack available to order separately. ++ Wall Channels ordered separately. See below. BST10R Packaged in Metal Bracing Rack. ++ Wall Channels (Bracing Not Included) 8 (2 m) CHA-8* 10 (3 m) CHA (4 m) CHA-12 Channels/Bdl Metal Bracing Rack - BRRACK Round Tube Bracing w/10 Wall Channels Round Tube Bracing w/12 Wall Channels Includes Wall Channels 24 Guardrail Post 24 Catwalk Brackets 24 Turnbuckles 48 Gravity Pins Includes Wall Channels 24 Guardrail Post 24 Catwalk Brackets 24 Turnbuckles 48 Gravity Pins BRT10R* BRT12R* Packaged in Metal Bracing Rack. ++ Packaged in Metal Bracing Rack. ++ D Clip Gravity Pins - 6 (152mm) Includes 100/Box Includes 50/Box D-CLIP G-PINS Forward Fall Protection Pin Toe Kick Anchor Includes 40/Box Includes 40/Box FFGPIN TCLAMP *Special Order - production time required to fulfill order
37 NUDURA Tall Wall Adapter NUDURA Tall Wall Adapter Kit Includes 20 Scaffold to Turnbuckle Adapters 20 Channel to Scaffold Adapters 10 Scaffold to Scaffold Adapters TW-KIT* Tall Wall Nut & Cross Tie Kit Includes 50 Cross Ties 100 Nuts NUT-CR Connection Wires, Nuts, Cross Ties Tall Wall Connector Wires - 14 (356 mm) Includes 100 Connector Wires TWCW14 Scaffold to Turnbuckle Adapter Channel to Scaffold Adapter Scaffold to Scaffold Adapter 37 Diagram above illustrates Tall Wall Adapter Kit on Bracing. For reference only. *Special Order - production time required to fulfill order. NOTE: Tall Wall only compatible with square tube bracing. 37
38 Customer Service and Support Technical support & customer service. A NUDURA Authorized Distributor can provide you with extensive technical support and service such as: installation recommendations, up-to-date code compliance advice, product information, and installation applications. A local distributor can also supply stock for smaller jobs. Contact your local distributor for details or call Professional online tools & resources. The NUDURA website provides contractors, architects and design professionals with a full design details library, installation manual, how-to videos, a vast project photo gallery, and much more. To access our online tools & resources go to nudura.com/resource-center. Basic installation training & AIA courses. NUDURA offers a one-day training seminar to provide builders & installers with basic NUDURA Insulated Concrete Form installation skills to ensure that you get the knowledge you need to get the job done with efficiency and confidence. To locate a training course held in your area visit nudura.com/training. To provide you with current industry standards, NUDURA is also a registered provider with the AIA Continuing Education System. For more program information visit nudura.com/aia
39 Notes Download our Product Information Centre ipad App. 39
40 Contact us for a distributor near you Over 50 years of building experience. By using NUDURA Insulated Concrete Forms to build your next structure you can ensure you are choosing the best building solution available today. The information contained in this NUDURA Product Guide is presented only for the purpose of providing information on the various products forming part of the NUDURA Insulated Concrete Wall Forming System ( NUDURA ). This NUDURA Product Guide SHALL NOT be used as a substitute for professional engineering consultation. NUDURA makes no general warranties to the specific applicability of any of the products to any or all situations for which a designer may elect their specific use. Final amendment or modification to suit the exact circumstance of employment any such products is the responsibility of the project designer. NUDURA has no control over the installation or workmanship used in the assembly or the installation of NUDURA. Therefore, NUDURA shall not be liable for any general, special, direct, indirect or consequential damages, including bodily harm that may be suffered by any person including, without limitation, the installer, contractor, architect, engineer, homeowner or customer due to the use, assembly or installation of NUDURA. The NUDURA Products described herein are sold subject to the NUDURA Corporation Limited Warranty. ND1505E are trademarks of NUDURA Corporation
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
Built to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
innovation makes us the better building choice.
ND1402UK are trademarks of NUDURA Corporation. 2014 Enermodel Engineering innovation makes us the better building choice. the principle is simple. NUDURA Insulated Concrete Forms offer a variety of superior
architect builder/developer contractor design professional
architect builder/developer contractor design professional Buildings today demand reliable, energy efficient building envelopes that provide superior performance benefits to minimize energy costs, reduce
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS The LOGIX wall assembly has no need for an additional vapor barrier, the solid concrete core covered with the low permeance EPS (Type II) foam
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
5.0 wall ApplicAtions
5.0 Wall Applications 5.1 Below Grade Walls Properly reinforced Arxx ICFs with a nominal concrete core width of 6 (150 mm) are demonstrably more resistant to lateral earth pressures than 8 (200 mm) plain
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
COMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
DELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the
Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
STANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
glass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.
ICC-ES Evaluation Report ESR-2270 Reissued September, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
2.9 WINDOW & DOOR BUCKS
2.9 WINDOW & DOOR BUCKS Bucks provide attachment surfaces for windows and doors while holding back concrete from these openings during concrete placement. Mark the center and edges of openings as you place
How To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11
Proven roofing SyStemS
Proven Roofing Systems Above all. Roofing challenges are never over our heads At GenFlex, we live to tackle and solve the toughest challenges in roofing. The result is a full line of proven, durable roofing
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. awipanels.com From freezing, sub-zero temperatures to Contents dry heat or high humidity, Mother Nature continually tests the limits of building envelopes. That's
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
Ver. 2. Guide to. Inspecting Residential Brick Veneer
Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan
Composite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.
Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION
SikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
AMERICAN GOTHIC PLAYHOUSE
AMERICAN GOTHIC PLAYHOUSE Project Plan #856 Sheet 1 of 5 Pick a spot and get started with the beautiful that your kids will love. The design of the playhouse includes 35 square feet of interior space plus
WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
Building Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
Protecting Your Home from Wind Damage
Protecting Your Home from Wind Damage During severe thunderstorms or hurricanes, homes may be damaged or destroyed by high winds. Debris flying through the air can break windows and doors, allowing high
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards
Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
Building Envelope Design using ROXUL Building Envelope Design using ROXUL (BEDR ) FIREWALL and ROXUL PLUS MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB
Protecting Your Home From Hurricane Wind Damage
T H E W I N D Protecting Your Home From Hurricane Wind Damage During a hurricane, homes may be damaged or destroyed by high winds and high waves. Debris can break windows and doors, allowing high winds
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
Residential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior
Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions
Y Parts Included: Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions Tools Required: Power Driver Drill Bit (Determined by fastener) Driver Bit (Determined by fastener)
RZ Guardrail System Installation Manual
TM RZ Guardrail System Installation Manual RZ Guardrail System Compliance is based on OSHA standards: (Standards - 29 CFR) 1910.23 (e) and (Standards - 29 CFR) 1926.502 (b) Failure to read, understand
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS ROXUL SAFE 55 & 65 and ROXUL PLUS MB Insulation for Pre-Engineered Metal Buildings ROXUL SAFE AND ROXUL PLUS MB Exterior Wall Insulation for Pre-Engineered
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick
Photo courtesy of Delta Stone, Heber City, UT Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick THIN VENEER INSTALLATION SYSTEMS PREMIUM BONDING MORTARS Premium PCL Stone
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver
Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver Designing an Effective Envelope Roofs Below Grade Walls and slabs Glazing & Windows Opaque portions of walls 2 3 Energy
Natural Thin Stone Veneer
Natural Thin Stone Veneer Until recently, if a project called for the natural look of stone but could not support its weight or thickness, the options were limited to manufactured imitation stone. More
12.1 Schlüter -KERDI-BOARD
I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter
TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"
2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE
2. Division 05 Structural Steel Framing for steel framework requirements
SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
How to secure your property after a disaster
How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,
Designed and Engineered to Perform
History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the
Nudura. Building Has Evolved. Energy Efficient. Environmentally Friendly. Superior Strength. Maximum Comfort.
Nudura. Building Has Evolved. Energy Efficient. Environmentally Friendly. Superior Strength. Maximum Comfort. THE RIGHT CHOICE FOR YOUR NEXT HOME FOR MORE THAN ONE REASON Homes today have to be more than
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...
Building Insulations - Walls and Ceilings (FM Approval Numbers 4411, 4651, 4880, 4881, 4882) Insulating materials may occur in building construction to reduce heat or sound transmission through a wall,
Additions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE
STRUCTURAL INSPECTION REPORT DRAFT 201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE TOWN OF PRESCOTT Date: November 2013 GENIVAR No.: 131-20617-00 2611 Queensview Drive, Suite 300, Ottawa,
DE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
Fire Barrier Duct Wrap 15A
3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies
Dock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
AZEK Rail Install Guide
TRIM MOULDING DECK PORCH RAIL PAVERS AZEK Rail Install Guide Installing AZEK Rail with CableRail by Feeney... 1 Installing CableRail by Feeney for AZEK Rail... 7 Installing AZEK Rail Stairs with CableRail
Installation & Technical Guide
Of the very few negative responses that I have received regarding this product, the one that I find most humorous is this one: Contractors are too rough on the product. I don t think this can stand up
Owner's Manual & Assembly Instructions
Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY
Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996
CITY OF SAN JOSE BUILDING DIVISION POLICY Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 All new and replacement water heaters installed
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
Quality You Can Trust Since 1886... From North America s Largest Roofing Manufacturer
Quality You Can Trust Since 1886... From North America s Largest Roofing Manufacturer Leak Buster Repair & Maintenance Products Quality You Can Trust Since 1886...From North America s Largest Roofing Manufacturer
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In
Family GUIDE FOR RESIDENTIAL applications Foamular Where quality and performance make a home The OWENS CORNING FOAMULAR XPS INSULATION FAMILY ALBUM is a critical feature of any home impacting overall comfort
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
*** MAIN VERSION OF BOM ***
*** MAIN VERSION OF BOM *** This is the main parts list for the 2013-2014 FTC game. The parts are listed in different categories (such as "Field Elements, "Hardware," "Wood," etc.). The item numbers assigned
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
Basement Moisture Problems
Foundations Foundation Purpose The purpose of a foundation is to distribute the weight of a structure securely into the ground. Engineering data regarding soil, rock and water conditions are used to design
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
Building Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and