Division 8 Doors & Windows
|
|
|
- Deirdre Ball
- 10 years ago
- Views:
Transcription
1 Division 8 Doors & Windows Basic Door and Window Materials and Methods 1. Has a minimum door leaf size of 3-0 x 7-0 been specified for both interior and exterior doors? 2. Has the door height been standardized at 7-0 (rather than 6-8 )? 3. If fume hoods or other large equipment are included in the project, or may be required in the future, have doors been sized to allow for moving the items in and out? Have both exterior and interior doors been addressed for this requirement? 4. Has at least one main entry door accessible from adjacent sidewalks by wheelchair (the accessible path) and does it display the proper handicapped signage? Have all other entry doors been provided with proper signage per ADA/ANSI standards to direct handicapped persons? All doors must comply with ADA/Florida Building Code requirements for size, opening/closing force, time delay on closer-equipped doors, etc. 5. Do all exterior doors comply with Florida Building Code (wind loading, etc.) and all other applicable codes? 6. Do all doors used as means of egress (including those in corridors) that require vision panels have approved vision panels installed to meet NFPA 80 and other applicable code requirements? 7. Do all operable items on exterior doors have an integral finish --not applied, painted, baked on, etc.? 8. Are all doors requiring fire ratings clearly identified on the schedule and have frames and hardware been coordinated to match the required rating? 9. Are all doorways numbered? Door numbers shall relate to the adjacent room numbers. 10. Has the following been specified (coordinate with Division 9 Finishes): For solidcore wood doors and hollow metal doors 2 8 to 4 0 wide (200 lb. max.), rough framing shall be 20-ga. steel studs and runners. For heavy doors up to 4 0 wide (300 lb. max.), two 20-ga. studs shall be used. For doors over 4 0 wide, double doors and extra-heavy doors (over 300 lb.), framing shall be specially designed by the A/E to meet load conditions. Rough framing for all doors in fire-rated partitions shall be 20-ga. studs and runners. June 2010 Division 8 Doors & Windows 1 of 8
2 Steel Doors and Frames 1. Do hollow metal frames have mitered or coped and welded corners? Knock down frames are not preferred. 2. Have exterior HM frames been specified to be at least 14 gauge hot-dipped galvanized? 3. Have interior HM frames been specified to be at least 16 gauge galvanized? 4. Are all exterior HM doors Extra Heavy Duty, seamless? Glazing if used must be non-reflective. Has weatherstripping been specified on all exterior doors? 5. Are all interior HM doors Heavy Duty, seamless? 6. Exterior louvered HM doors are not allowed. Has this been coordinated with the engineers? Wood Doors 1. Do all wood doors meet the ANSI/WDMA I.S.1A Standard for Architectural Wood Doors? 2. Are all wood doors solid core? Hollow core doors are not approved. 3. Has the A/E specified that doors shall contain no added urea-formaldehyde resins? 4. Are all wood doors 1-¾" solid core? 5. Do all doors meet the requirements of NFPA 80 and 101 where applicable, and are they able to use standard locksets? 6. Where cutouts for closers are required, has the head rail been specified to be not less than 6 inches? 7. If hardwood edges are desired have they been clearly specified with the thickness given? 8. Do all doors used as means of egress (to include corridors) and all fire rated doors that require vision panels have approved vision panels installed to meet NFPA 80 and other applicable code requirements? June 2010 Division 8 Doors & Windows 2 of 8
3 9. Is wood door quality clearly specified as well as approved manufacturer's names? At least 3 manufacturers must be specified Entrances and Storefronts 1. Has it been specified that all entrances, storefronts, and windows shall be clear anodized aluminum finish? 2. Has a medium stile entrance door been specified? Narrow stile is not allowed (interior doors also). 3. Do all entrances comply with Florida Building Code (wind loading, etc.) and all other applicable codes? Narrow stile doors are not allowed in any condition Metal Windows 1. Has consideration been given to the provision of operable windows as a means of ventilation in the event that air conditioning equipment is not in operation? Are operable windows provided with positive locking devices? 2. Have all classroom windows, unless otherwise advised by FAU Facilities Planning Project Manager, been equipped with audiovisual blinds or acceptable window coverings? Has this been coordinated with Division 12 Furnishings? 3. Have guardrails at all full height glass panels been specified in accordance with applicable codes? 4. Are all exterior windows specified to comply with Florida Building Code requirements? (Wind loading, etc.) Finish Hardware 1. Is the hardware schedule included in the specification? (This is to avoid change orders and delay in taking bids. A completely itemized schedule is preferred, i.e., not a group listing (see attached fall hardware spec). A cash allowance for finish hardware shall not be used unless otherwise authorized. Locksets 2. Has the lockset manufacturer for all FAU work (except Housing and Residential Life Department) been specified to be Sargent Manufacturing Co. only with no substitutes allowed? 3. Has the lockset manufacturer for all FAU Housing & Residential Life Department work been specified to be Best Access Systems only with no substitutes allowed? June 2010 Division 8 Doors & Windows 3 of 8
4 4. Have mortise locksets been specified and are they Sargent 8200 series with L lever handles, LN roses, and removable cores? Have classroom locksets been specified to be Sargent 8225 or 8256 series? 5. Have the removable cores been specified to be Sargent 6-pin old style 51 prefix with FAU restricted keyway for Boca Raton and Northern Campuses projects? 6. Have the removable cores been specified to be Sargent 5-pin new style 63 prefix with FAU restricted keyway for Broward Campuses projects? 7. Does the specification state that the hardware supplier must be authorized by Sargent and approved in writing by FAU? Butts 8. Have 5-knuckle, button tip, full mortise, template type stainless steel ball bearing butts with non-rising loose pins been specified? Exit Devices 9. Has Sargent 8800 series FLL or ETL in finish compatible with door been specified? At exterior pairs of aluminum doors, have Kawneer Panic Guard, or comparable, entrances been specified? 10. Have exit devices been specified to be Sargent 8800 series rim-type? 11. Have all electrically controlled exit devices been specified to have steel dogging screws and to be 2-wire? 12. Do all building entrance/exit doors contain exit devices with concealed vertical rod? Surface vertical rods for exit devices are not acceptable due to handicapped interference. Closers 13. Are closers specified to be surface applied Sargent 351 series or LCN 4040 series (both interior and exterior doors)? Is the cover finish powder coat aluminum enamel? 14. Are closers at interior doors specified to be mounted on the room side of doors so as not to be visible from corridors, lobbies, and other public spaces? 15. Has it been specified that all closers shall comply with Florida Building Code and ADA requirements for closing strength, speed, (and delayed action if required) and June 2010 Division 8 Doors & Windows 4 of 8
5 A/E has verified that closers specified will meet this requirement? Stops 16. Are wall-mounted convex rubber bumpers with concealed fasteners specified? At drywall partitions, has solid blocking been specified within the stud space? Floor stops are to be used only where wall bumpers cannot be used. Kickplates 17. Are 8 inch high stainless steel kickplates specified on doors subject to severe use? Office doors generally do not require kickplates. Provisions for Noise Control 18. Has weatherstripping been called for at heads, jambs, and sills at machine room and other doors where excessive noise is anticipated? Has the A/E determined if surface applied automatic door bottoms are be required? (Specific drawing sheet #/specification page # ) Hardware for Metal Entrance Doors 19. Is all hardware for metal entrance doors furnished under this Division 8 Doors & Windows (unless otherwise noted)? Has it been specified that the hardware supplier furnish to the door manufacturer templates or the actual hardware? Thresholds 20. Do all thresholds meet Florida Building Code and ADA requirements? Are thresholds at trash, receiving, recycling rooms, etc., that will require regular movement of wheeled carts as low as possible (if required at all) and shaped to allow easy movement of carts? Finish (unless otherwise noted) 21. Have interior finishes been specified to be brushed stainless steel (US32D) or brushed chrome (US26D)? Have exterior finishes been specified to be brushed stainless steel (US32D)? Have accessories been specified to have compatible finishes? Standards and Approved Equals 22. For each item except locksets and closers, has one manufacturer been specified and scheduled as the standard and, whenever possible, two other manufacturers whose products are PROVEN EQUAL? 23. Has a complete list of items proposed as the standards, together with manufacturers' names and with the names of manufacturers whose products are equals, been included in the hardware schedule? This schedule must be approved June 2010 Division 8 Doors & Windows 5 of 8
6 by the Owner at 50% Construction Documents. Keys and Keying 24. Is each lock cylinder compatible with specified hardware and with existing university hardware and keying systems? 25. Has the A/E specified that the Contractor shall schedule a keying meeting six (6) months prior to Substantial Completion? Attendees will be the Contractor, FAU Facilities Planning Project Manager, user group representative(s), hardware subcontractor, and Sargent representative (s). 26. Is each lock cylinder operated by one of the following keying system: a. One (1) new Master Key established for this project (if applicable). b. Existing Grand Master Key. c. Existing Great Grand Master Key. 27. Has it been specified that key bows shall be stamped on one side "PROPERTY OF STATE OF FLORIDA - DO NOT DUPLICATE" and on the other side with keyset symbol? (Specific drawing sheet #/specification page # ) 28. Has the final keying been reviewed with the university prior to issuance to the Contractor? 29. Have the keys been provided as follows (verify for each project): a. No Grand Master Keys. b. Ten (10) Master Keys. c. Ten (10) keys for each Submaster established. d. Four (4) Change Keys per lock. e. Provide Change Key blanks at a quantity of two (2) times the total quantity of cores provided for the project. ("S" bow, stamped). f. Twelve (12) Construction Master Keys "CMK". 30. Has it been specified that each project shall be a Construction Master Key project? All locks shall be shipped to the jobsite operated only by the Construction Master Key. Permanent keys, together with the Key Bitting Record, shall be sent via registered mail direct from the factory to: FAU Facilities Planning Dept., Project Manager (name), Florida Atlantic University, 777 Glades Road, Building CO-69, Room 107, Boca Raton, Florida, Automatic Door Opener 31. Has an electric-powered automatic door opener been scheduled for each major exterior entry to the building? Only one door leaf needs to be provided with the automatic opener when the entry consists of multiple doors. Standard operator is Nabco Gyro Tech GT-500 system. Activators are Linear transmitters-receivers. Transmitters are battery powered. Pushplates are 6 ¼ diameter brushed stainless June 2010 Division 8 Doors & Windows 6 of 8
7 steel with engraved handicap symbol. Microswitch and transmitter fit within a standard 4 square junction box. Verify transmitter frequency is 310MHz Schedules 1. Does the hardware schedule relate to the FAU-approved room numbering system (see Division 10 Specialties, Section Identifying Devices)? 2. Has the keying system been reviewed with the users and FAU Facilities Planning Project Manager? Card Access Control System 1. Has a complete, operable, tested and certified Card Access Control System (C.A.C.S.) been specified? 2. Is the specified system Software House-C. Cure 800 System? 3. Has the C.A.C.S. been designed and specified to connect to and interface with the Campus Central Control System through the campus data system? 4. Has the Campus Central Control System been analyzed to verify capacity for the proposed new access control system? If the Central Control System requires an upgrade of hardware or software to function properly campus-wide after the addition of the proposed new access control system, has the upgrade been designed and specified as a part of this project? 5. Has it been specified and scheduled that an adequate number of exterior entry doors are controlled by card readers and connected to the C.A.C.S.? A/E shall confirm locations with FAU Project Coordinator. 6. Has it been specified and scheduled that all exterior doors are connected to the C.A.C.S. and monitored for open-close conditions? 7. Has it been specified that all exterior doors not normally locked all of the time (such as stairways, secondary emergency exits, etc.) are connected to the C.A.C.S. and are equipped with electric locks so the FAU Police can remotely lock-down and unlock buildings through the C.A.C.S? (Specific drawing sheet #/specification page # ) 8. Have all wiring/cabling, operating devices, door contactors, relays, controls panels, boxes, grounds, and testing been specified to be performed by a systemmanufacturers' factory-trained and certified installer? 9. Have all C.A.C.S. devices been shown on the construction documents and has the A/E coordinated all electrical requirements with the electrical drawings and June 2010 Division 8 Doors & Windows 7 of 8
8 specifications, including raceways in door frames and j-boxes? 10. Has a campus data port been provided at the C.A.C.S. Building panel location? 11. Has a 4 x 4 x ¾ plywood backboard been specified to mount the C.A.C.S. equipment? 12. Has a dedicated 110v/20A circuit been provided at the C.A.C.S. building panel location? 13. Has the C.A.C.S. building panel and all hardware on the C.A.C.S. system been tied into the building s emergency power supply, and if the building does not have an emergency generator has a UPS been specified that will provide a minimum of 24 hours of backup power? Glazing 1. Has each glass type been noted clearly and concisely on the drawings with a Type Number? Lengthy descriptions do not go on the drawings, but are to be in the specifications. 2. Has each glass type been precisely defined in the specifications? 3. Where glass is used in in toilet, bathroom, etc., windows, is it obscure? 4. Is all window glass replaceable from inside the building wherever feasible? 5. Does all glass meet the requirements of the Florida Building Code, Life Safety Code, and all other applicable codes? (Wind loading, safety glazing, etc.) (Specific drawing sheet #/specification page #- ) 6. Has it been specified that windows should be glazed in the closed position and left closed for several weeks? (This applies particularly to awning or projected types.) 7. Has it been specified that all exterior glass on the FAU Boca Raton campus shall be Atlantica spectrally selective tinted glass by PPG (green tint - formerly Solargreen), or approved equal? Standards for ¼ (6mm) monolithic glass are: 67% visible light transmittance, 0.52 solar heat gain coefficient, 0.61 shading coefficient. End of Division 8 Doors & Windows. June 2010 Division 8 Doors & Windows 8 of 8
SECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401
BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential
DIVISION 08 70 00 HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.
FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat. BASIS OF DESIGN 1. APSU design standards shall not replace fully developed, project and market specific
DIVISION 08 70 00 HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.
FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat. BASIS OF DESIGN 1. BGSU Design Standards shall not replace fully developed, project and market specific
Automatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 [email protected] Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
CONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE
CONCEALED BEARING HINGES StANLEy ARCHItECtuRAL HARDwARE STANLEY ARCHITECTURAL HARDWARE TABLE OF CONTENTS Page Table of contents...2 Company history...2 5 knuckle concealed bearing design...3 Full mortise
HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF
Stainless Steel Continuous Hinges
Stainless Steel Continuous Hinges Hager heavy duty continuous hinges offer proven reliability that can stand up to the daily rigors of high-traffic, high-impact areas. They re designed and engineered to
Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.
Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal
MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: MEANS OF EXIT / ESCAPE / EGRESS Guidelines: This checklist covers some of the regulations
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots
2.02 Standard Specifications General Entrances Description Furnish all necessary materials, labor and equipment for the complete installation of aluminum entrance doors, door frames and hardware as shown
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame
Weather Fin and bulb help keep bad weather outside and good air inside Windows: n Many light kits are available 1-LU 4 X 48 1-LE 16 X 16 1-LA 20 X 24 1-LI 20 X 24 1-B 22 X 36 1-LW 16 X 16 W/GRID 9-LB 22
Fire-rated Aluminum Doors
Fire-rated Aluminum Doors Langebjergvænget 13 ALUFLAM has pioneered the innovative solution to what was long considered an impossible dream (and a barrier to truly beautiful commercial architectural design),
1.1.2. Minimum gauges for doorframes shall be 16 gauge for interior frames and 14 gauge for exterior frames. Exterior frames shall be galvanized.
DIVISION 8 - OPENINGS SECTION 081000 - HOLLOW METAL DOORS AND FRAMES 1. General Requirements: A/E shall specify that door and frame sizes and details conform to industry stock standards wherever possible.
Wood Sound Retardant Door Hardware Information Bulletin
overly overly 574 West Otterman Street Greensburg, PA 15601 Toll Free: (800) 979-7300 Local: (724) 834-7300 Fax: (724) 830-2871 Email: [email protected] DOOR COMPANY Wood Sound Retardant Door Hardware
Basic Fire Door Requirements
TECHNICAL DATA SERIES S D I 118-01 Basic Fire Door Requirements 2001 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2001 Basic Fire Door
Fire-Rated Doors and Hardware. A Guide to Field Inspection
Fire-Rated Doors and Hardware A Guide to Field Inspection Foundation s Mission To promote secure and safe openings that enhance life safety Awareness To be a source of information through awareness campaign
WINDOW PANNING AND TRIMS
OCTOBER, 2010 PANNING AND TRIMS GENERAL INFORMATION 1 EXTERIOR PANNING Panning is primarily used to cover the perimeters of existing building openings prior to the installation of replacement windows.
Architectural Casework 06400-01. 1.01 Description of Work
06400-01 1.01 Description of Work A. Extent of each type of architectural millwork and casework as indicated on drawings. Types of architectural casework shall include both stained and plastic laminated
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION
Frost and Cooper Renovations
Barton Malow Company LIVONIA PUBLIC SCHOOLS Livonia, Michigan Frost and Cooper Renovations BID PACKAGE No. 1 ADDENDUM # 3 February 17, 2014 Barton Malow Company Frost and Cooper Renovations MEMORANDUM
190/350/500 Standard Entrances
AUGUST, 2015 FEATURES 1 Features 190 narrow stile has 2-1/8" (54) vertical stile, 2-1/4" (57.2) top and 3-7/8" (98.4) bottom rail 350 medium stile has 3-1/2" (88.9) vertical stile, 3-1/2" (88.9) top and
HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 830-02 METAL S & FRAMES 8d NAAMM 01 02 HARDWARE SELECTION FOR HOLLOW METAL S AND FRAMES NAAMM 01 02 8d METAL S & FRAMES A Division of HOLLOW METAL MANUFACTURERS
DE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
Architectural Testing PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Mahogany Entry Door PRODUCT TYPE: 6' x 8' Double Outswing Hardwood TDL Door with Half Circle TDL Transom
CLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)
Custom Blank Entrances - Applied Hardware & Preps - Tubelite Standard Hardware Butt Hinges Pivots C2 Page 1 P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing) P795S
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1
Decorative Lever Designs
Decorative Lever Designs 3 & C 4 & K 12 14 & D 15 & A 16 & B 17 50 51 52 53 54 55 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 2 www.stanleysecuritysolutions.com
Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art
D O O R F R A M E S Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers Industries
An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks
An ASSA ABLOY Group brand 4800LN Series Interconnected Locks performance meets style introduction The Yale 4800LN series interconnected locksets combine our key-in-lever locksets with the added safety
C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.
SECTION 081216 - INTERIOR ALUMINUM DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
Flexivent Windows (1952 to 1979)
Flexivent Windows (1952 to 1979) Parts Catalog Main Menu Section TOC Search What s in This Section Standard Windows................................................ Page 3 Parts Illustration...........................................................
WINDOW AND DOOR REPLACEMENT REQUIREMENTS
WINDOW AND DOOR REPLACEMENT REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern.
Technical Data Honeycomb Door Leaf 8-1-99
8--99 8-/8 8-7/8 B 8-/4 A A Dim. A Leaf Width B ELEVATION F DESIGN Vertical edge seams mechanically interlocked Square hinge and lock edges 4-/ x.4 full mortise hinge prep Gov. 60/6 cyl lock prep...prefix
Basement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
quality door and window systems for metal buildings
quality door and window systems for metal buildings knock-down door systems Features and Benefits: Galvanized Doors and Frames Insulated Door Cores Textured Steel Door Faces Completely Reversible (non-handed
Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
Auxiliary hardware & general information. Exit devices
Auxiliary hardware & general information Exit devices Introduction Since pioneering the first exit device in 1908, Von Duprin life safety products have provided unparalleled quality, performance and flexibility
Casement/Awning Window Parts Reference Catalog
Casement/Awning Window Parts Reference Catalog (Includes Miscellaneous Parts for Eyebrow Casement and Garden Bay Windows) #1028654 (Revised 03/02) Weather Shield Mfg., Inc. Medford, WI 54451 715/748-2100
Classroom Door Security & Locking Hardware
Classroom Door Security & Locking Hardware The ability to protect students and teachers while in the classroom is a high priority in all educational institutions. Many schools and school districts have
CLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.
FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds
PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Buffalo Forge Steel Doors / Round Top Single PRODUCT TYPE: In-swing Round Top Single Door RH-4 Title Uniform Load Deflection Test
BUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 831-11 8d NAAMM HMMA 831-11 METAL DOORS & FRAMES HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES 8d NAAMM HMMA 831-11 METAL DOORS & FRAMES A Division of HOLLOW
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Providing the widest selection of quality vinyl and aluminum window & door products.
Providing the widest selection of quality vinyl and aluminum window & door products. KELTIC DOOR SERIES At International Window, quality is our trademark. That is why we leave nothing to chance. Today,
DIVISION 8 DOORS AND WINDOWS
DIVISION 8 DOORS AND WINDOWS A. FINISH HARDWARE AND SPECIALTIES 1. General a. It is the intent of this document to provide guidelines for the Architect's specifications section 08710, finish hardware.
SECTION 14 20 10 - FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL
SECTION 14 20 10 - FREIGHT & PARKING GARAGE PART I - GENERAL 1.1 SECTION INCLUDES [NOTE to AE: The following lists requirements that are specific to freight elevators. These requirements are in addition
Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...
Door Hinges Contents Butt hinges Lift-off hinge Rising hinge Standard hinge Heavy duty hinge Parliament hinge Spring hinge Double action spring hinge Concealed hinges Concealed mortise hinge... Pivot
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)
NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning) Summary of Results Standardized Thermal Transmittance (U-Factor)
FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL
FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:
280+ Mortise Mounted Series Shear Locks Special Application Solution
280+ Mortise Mounted Series Shear Locks Power Plus control module overcomes gaps of up to 1/4" Low Temperature Operation 280+ TRD Locknetics provides the industry s most complete selection of electromagnetic
Simplex 1000 Series. All Simplex Controls are less I.C. core. 1000 Series packed with both ASA and T strike.
Kaba Mechanical Lock Price Book, May 1, 2015 Simplex 1000 Series All Simplex Controls are less I.C. core. 1000 Series packed with both ASA and T strike. KNOBS 26D 05 03 1011 Standard Access Control 450.50
9300BC SERIES Light Commercial Door Closer
Light Commercial Door Closer general information The 9300BC is a durable, economically priced door closer designed for commercial exterior and interior doors such as storefront and industrial applications.
Securing your school. Door hardware solutions for primary education
Securing your school Door hardware solutions for primary education Security at every layer Successful school operation combines a safe and secure environment with the freedom needed to focus on education.
Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN
Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN Installation Instructions Structural Information For standard systems and most custom single door opening systems. General Overview
REQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $
REQUEST FOR QUOTE Specifications- Knightdale Station Park Naming Rights Exterior Signage General Conditions 1. Delivery of signs to be within 6 weeks of order confirmation. 2. Shop drawings are required
Installation Instructions and Ordering Information
The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.
Breezway Altair Powerlouvre Window 35 Breezway Altair Powerlouvre Window The Powerlourve Window motor is neatly concealed within the Easyscreen TM Frame or the Component Powerlouvre Head Section. Automated
Reachout Lock Replacement for Andersen 2-Panel and 4-Panel 400 Series Frenchwood Gliding, 200 Series Narroline, and Perma-Shield Gliding Patio Doors
for Andersen 2-Panel and 4-Panel 400 Series Frenchwood Gliding, 200 Series Narroline, and Perma-Shield Gliding Patio Doors Thank you for choosing Andersen. For questions call 1-888-888-7020. For more information
FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES
FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke
DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION 17650 SECURITY SYSTEMS
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Inspections and observations by the Owner do not relieve the A/E of contract responsibilities. B. Chain of command 1. The DPS Project Manager is
SECTION 08560 SERIES 1500 VINYL PATIO DOORS
SERIES 1500 VINYL PATIO DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Patio Doors 1.2 RELATED SECTIONS A. Section 05450: Cold Formed Metal Framing. B. Section 06100: Rough Carpentry. C. Section 06200: Finish
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES
GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES PAGE 13 DESIGN GUIDELINES The following design guidelines have been developed to guide appropriate design in the Downtown
SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)
SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) Construction Criteria The unit costs for ADP Mainframe space types are based on the construction quality and design features in the following
MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B8049.01-401-18. Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida
Architectural Testing MIAMI-DADE COUNTY PERFORMANCE TEST REPORT Report No.: B8049.01-401-18 Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida PRODUCT TYPE: Aluminum Storefront with Double Doors SERIES/MODEL:
INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1
City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included
A Complete Solution CREATING WALLS THAT DEFINE SPACE
A Complete Solution CREATING WALLS THAT DEFINE SPACE COMPANY HISTORY CLIPPER WALL Clipper partitions are part of the Saint- Gobain Group, one of the worldwide leaders in the construction products industry.
Class A Office Buildings Commercial Facilities College and University Campuses K-12 Buildings Healthcare Facilities Government & Military Structures
Bringing New Light to Interior Architecture Expansive New Light Frameworks brings new light to interior architecture with doors, frames and windows that pair custom and standard glazing options with an
Sliding Door Hardware Installation Instructions
Sliding Door Hardware Installation Instructions Installation Instructions Structural Information For standard systems and most custom single door opening systems. General Overview ff All Krown Lab sliding
Garden Windows Builders Vinyl
TABLE OF CONTENTS Specifications... 8-2 QuickSpecGuide... 8-3 Elevations/Sizes: 1/4 Scale GardenUnits... 8-4 Grille Patterns... 8-5 SectionDetails: 6 Scale... 8-6 December 2008 JELD-WEN reserves the right
Degree Key System. Technical Manual
Degree Key System Technical Manual Copyright 03-04, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission
TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE
TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means
Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4
TABLE OF CONTENTS A Adjustable Angle Bracket (294/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)... 7 C Coordinator Mounting Bracket (2950 Series)... 7 Concealed Magnetic
17,280 square feet Overview:
CENTRAL OFFICE Located at 167 Boston Post Road, East Lyme, Connecticut, the Central Office was built in 1916 as the original Flanders Elementary School and remains connected to the current school. The
Door Hardware Lock Specifications
Door Hardware Lock Specifications Directory Lock Type Page Exterior Mortise Lock Specifications... 2 2.5 Backset Mortise Locks Specification... 3 2.5 Backset Mortise Lock Functions (6301, 6310, 6315, 6318,
Confort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
Installing Window and Door Mouldings
Installing Window and Door Mouldings About Window and Door Mouldings The trim around windows and doors greatly influences the look and style of your interior. They also bridge the gaps and cover spaces
Understanding Access Control
Understanding Access Control To understand access control, we must understand the language of the industry. Terms like alarm inputs, relays, timezones, anti-passback, shunt, and access levels are commonly
Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.
SECTION 08333 ADVANCED UPCOILING SECURITY GRILLE MODEL 600 ADV Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Advanced Upcoiling Security Grilles,
Standard Door Specification
Element General Requirement To be defined in the project brief but should meet Building Regulations. All doors to be a minimum of 30 minute fire rated and must comply with all relevant UK legislation and
Doc 10. UTM Standards: Card Access Security System
Doc 10 UTM Standards: Card Access Security System 1. GENERAL... 2 1.1. GENERAL REQUIREMENTS.... 2 1.2. SUMMARY OF WORK INCLUDED... 2 1.3. OVERVIEW... 2 1.4. MANDATORY REQUIREMENTS... 3 1.5. ACCESS CONTROL
A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
STANDARD MATERIAL SPECIFICATIONS FOR OUR PREFAB BALI HOUSES
STANDARD MATERIAL SPECIFICATIONS FOR OUR PREFAB BALI HOUSES We offer four main prefab building material options, viz. a Basic, a Standard, a DeLuxe and a, each of them fitted to your budget or requirements.
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for