VI Brick Thermal Management

Size: px
Start display at page:

Download "VI Brick Thermal Management"

Transcription

1 APPLICATION NOTE AN:200 VI Brick Thermal Management Contents Page Overview 1 Efficiency and Dissipated Power 1 Radiation 2 Conduction 2 Convection 4 Free Convection 4 Forced Convection 6 Definitions 8 Overview VI Bricks allow access to the advantages of Vicor s VI Chip technology with increased options for thermal management. High operating efficiency minimizes heat loss, and the thermally enhanced low profile package features an easily accessible, electrically isolated thermal interface surface. Proper thermal management pays dividends in terms of improved module and system MTBFs, smaller size and lower product life-cycle costs. The following pages provide guidelines for achieving effective thermal management of Vicor s VI Bricks. Efficiency and Dissipated Power A VI Brick module takes power from an input source and provides regulation and/or current multiplication of the output power for delivery to a load. Not all of the input power is converted to output power however; some is dissipated as heat within the modules. The ratio of delivered output power to module input power is defined as the module s efficiency. Efficiency is a basic figure of merit that can be used to relate power dissipation directly to module output power. Thermal Equations 8 Typical Examples 9 Power Input = Power Dissipated as Heat + Power Output Input Source Figure 1. Dissipated power Power Dissipated = Power Output x ( 1 1 η ) Power Input x Efficiency ( η) = Power Output Load The first step in evaluating cooling requirements is to calculate worst-case dissipation based on module efficiency and worst-case anticipated load power. Clearly, higher efficiency will translate into lower power dissipation and simplify the cooling problem. Vicor VI Bricks have some of the highest efficiencies in the industry, with typical efficiency up to 97%. AN:200 vicorpower.com Applications Engineering: Page 1

2 Removing Heat From VI Brick Modules Heat is removed from VI Bricks through the flat metal baseplate on top of the module and through the module pins. The baseplate is thermally coupled to, but electrically isolated from, all internal heat-generating components. The basic thermal design problem is to transfer heat from the baseplate into the surrounding environment as a means of maintaining baseplate temperature at or below rated maximum. Heat energy is transferred from regions of high temperature to regions of low temperature via three basic mechanisms; radiation, conduction and convection. Radiation. Electromagnetic transfer of heat between masses at different temperatures. Conduction. Transfer of heat through a solid medium. Convection. Transfer of heat through the medium of a fluid; typically air. All three of these heat transfer mechanisms are active to some degree in every application. Convection will be the dominant heat transfer mechanism in most applications. Nondominant effects will provide an added contribution to cooling; in some cases, however, they may result in undesirable and unanticipated thermal interactions between components and subassemblies. All three of these mechanisms should begiven consideration when developing a successful cooling strategy. Radiation Radiant heat transfer occurs continuously between objects at different temperatures that are exposed to each other. The net effect on the temperature of an individual part is dependent on a great many factors, including its temperature relative to other parts, relative part orientations, surface finishes and spacing. The difficulty in quantifying many of these factors, combined with the universal presence of radiant energy exchange, makes calculation of radiational temperature effects both a complex and generally imprecise task. Temperature differentials encountered in practical applications of VI Bricks are never large enough to cause radiational cooling to be the dominant heat transfer mechanism. Radiation will account for less than 10% of total heat transfer in the majority of cases. For these reasons, the presence of radiant cooling is often assumed to provide safety margins over and above the dominant cooling mechanism, and detailed consideration of its effects are neglected. A valid assumption, in most cases, is that the module will be warmer than its surroundings and radiant energy transfer will aid cooling. In some cases, however, nearby objects (micro processors, power FETs, etc.) may be much hotter than the module and net radiant energy transfer may actually increase the module s temperature. Surveying the relative positions and estimated temperatures of modules and surrounding parts is advisable as a means of anticipating the potential effects of radiant transfer. In cases where hot components are n close proximity to the module, the use of interposing barriers can generally moderate undesirable radiational heating effects. Conduction In most applications, heat will be conducted from the baseplate into an attached heat sink or heat conducting member and through the module pins to the PCB. Cooling of the module through the board is a function of how much copper is surrounding the module, how much air is passing over that copper, and how much heat is coupled into the PCB from surrounding components. For the purpose of this application note, it will be assumed that there is no cooling of the modules due to the PCB and that all of the cooling occurs through the baseplate. AN:200 vicorpower.com Applications Engineering: Page 2

3 Heat conducted across the interface between the baseplate and mating member will result in a temperature drop which must be controlled. As shown in Figure 2, the interface can be modeled as a thermal resistance in series with the dissipated power flow. The baseplate temperature will be the sum of the temperature rise in the interface and the temperature of the member to which the baseplate is attached. Temperature rise across a surface interface can be significant if not controlled. The area of the interface should be as large as possible, and the surface flatness of the attached member should be within 5 mils. Thermal compound or a thermal pad should be used to fill surface irregularities. Thermal resistance across surface interfaces can be held to under 0.2 C/Watt with proper measures for VI Brick AC Front End converters and under 0.4 C/Watt for VI Brick PRM and BCM /VTM. Figure 2. Baseplate thermal considerations Surface Irregularities Produce Temperature Drop in the Interface Mating Member at Temperature = Ts Heat Flow θbs = Interface Thermal Resistance ( C/Watt) Baseplate Pdiss Power Dissipated by Converter (Watts) (+) Tb ( ) θ bs Tb = Baseplate Temperature = Ts + Pdiss x θbs + Ts Temperature of Mating Surface ( C) Many applications require that heat be conducted from the baseplate of the module to a remote dissipative surface via a thermally conductive member. The resulting baseplate temperature will be the sum of the temperature of the dissipative surface, the temperature rise in the heat conducting member, and the rises across the two surface interfaces. The thermal resistance of the conductive member is proportional to its length, and inversely proportional to both its cross-sectional area and thermal conductivity (Figure 3). Minimizing total temperature rise is dependent on controlling interface resistance, as described above, and controlling the thermal resistance of the transfer member through appropriate material selection and dimensioning. Figure 3. Interface thermal considerations Thermal Resistance of Conducting Member (θm) L θm = KA K = Thermal Conductivity A = Cross Sectional Area L = Length L θ bm Interface Resistance A θ ms Interface Resistance Cooling Surface at Temperature = Ts Pdiss (+) Tb θbm θm θms Power Dissipated ( ) by Converter (Watts) Tb = Baseplate Temperature θ θ θ Temperature of Cooling Surface ( C) = Ts + ( bm + m + ms) x Pdiss + Ts AN:200 vicorpower.com Applications Engineering: Page 3

4 Convection Convective heat transfer into air is a common method for cooling Vicor modules. Free or natural convection refers to heat transfer from a dissipative surface into a cooler surrounding mass of otherwise still air; forced convection refers to heat transfer into a moving air stream. The convection cooling model is shown in Figure 4. Baseplate temperature depends on the temperature of the air, total dissipated power and the values of two thermal resistances; the thermal resistance of the surface interface between the baseplate and the heat sink, and the heat sink-to-air thermal resistance. Surface interface resistance can be minimized as discussed under Conduction. The heat sink-to-air resistance is dependent on a variety of factors including heat sink material and geometry, air temperature, air density and air flow rate. Fortunately, thermal resistance data is available for a very wide range of standard heat sinks for use in both free and forced convection applications. The following sections will provide guidelines for both free and forced convection cooling of Vicor VI Bricks. Figure 4. Heat sink Surrounding Air Temperature (Ta) thermal considerations (+) Heat Flow Heatsink Baseplate Pdiss Tb θbs θsa Power Dissipated ( ) Ambient Air by Converter Temperature (Watts) Tb = Baseplate Temperature θbs = Baseplate-to-Heat sink Interface Resistance θsa = Heat sink-to-air Thermal Resistance Tb = Ta + ( θbs + θsa) x Pdiss + Ta Free Convection The benefits of free convection include low cost of implementation, no need for fans, and the inherent reliability of the cooling process. Compared to forced air cooling, however, free convection will require more heat sink volume to achieve an equivalent baseplate temperature To select a suitable heat sink for free convection cooling, follow these steps: 1. Determine the power to be dissipated by the heat sink. This should be based upon module efficiency and worst-case module power output using the formula given in the section on Module Efficiency and Dissipated Power (Figure 1). Power Dissipated = Power Output x ( 1 η ) 1 η = efficiency = P out P in 2. Determine the surface interface thermal resistance. Use of thermal compound or a thermal pad is recommended to minimize thermal resistance. This information is available on the VI Brick data sheets. AN:200 vicorpower.com Applications Engineering: Page 4

5 3. Referencing Figure 4, we can derive the following formula for heat sink-to-air thermal resistance: Θ sa = ( T b T a ) P diss Θ bs Ta = Worst case anticipated operating ambient air temperature. Qbs = Surface interface thermal resistance, from Step 2. Pdiss = Worst-case power dissipation, from Step 1. Tb = Baseplate temperature. Start with a value of Tb = 100 C to determine the maximum acceptable heat sink-to-air thermal resistance. 4. Select several heat sinks that appear physically acceptable for the application. Using data provided, obtain values for their free convection thermal resistance, preferably at worst-case ambient temperature, Ta. If values obtained are less than the value calculated in Step 3, go on to Step 5. If the values are greater, then either a physically larger heat sink will be required or a different cooling method will need to be used (i.e., forced air, etc.). 5. Select the heat sink with the lowest available thermal resistance consistent with space limits. Keep in mind that small reductions in baseplate temperature produce dramatic improvements in MTBF. 6. Baseplate temperature can be estimated by using the following formula: T b = T a + P diss x (Θ bs + Θ sa ) 7. Test to verify that performance is in line with expectations. Heat sink data is almost always given for vertical fin orientation. Orienting the fins horizontally will reduce cooling effectiveness. If horizontal mounting is mandatory, obtain relevant heat sink performance data or use forced convection cooling. Free convection depends on air movement caused by heat-induced density changes. Thermal resistance data is dependent on the heat sink fins being completely exposed to the ambient air without any significant interference to air flow at the ends of or along the length of the fins. If packaging will tend to block or baffle air movement over the fins, a larger heat sink might be required. In the worst case, free convection may be ineffective. Make sure that the fins are well exposed to ambient air. It is not necessary to limit the size of the heat sink to the size of the baseplate. Heat sinks with footprints larger than the baseplate area can often be used to advantage. In the latter case, heat must be conducted along the base surface of the heat sink to get to the outer fins, so don t count on achieving full cooling capability. Also, several modules can be mounted to a common heat sink, but cooling calculations must now take into account total power dissipation with consideration given to possible localized overheating if worst-case module power dissipations are greatly imbalanced. AN:200 vicorpower.com Applications Engineering: Page 5

6 Forced Convection Forced air can make a great difference in cooling effectiveness. Heat sink-to-air thermal resistance can be improved by as much as an order of magnitude when compared to free convection performance, by using suitable heat sinks. Consider the following data for baseplate-to-air thermal resistance (no heat sink) of VI Brick modules at various airflow rates. Forced air implies the use of fans. Many applications require that fans be used to achieve some desired combination of overall system reliability and packaging density. Industrial environments will require filters that must be changed regularly to maintain cooling efficiency, and neglecting to change a filter or the failure of the fan could cause the system to shut down or malfunction. Table 1. Baseplate to Air Thermal Resistance (no heat sink) *Not including PCB contribution - all thermal energy through baseplate only. Airflow VI Brick PFM Baseplate to Air Thermal Resistance* VI Brick AC Front End Baseplate to Air Thermal Resistance* VI Brick PRM Baseplate to Air Thermal Resistance* VI Brick VTM /BCM Baseplate to Air Thermal Resistance* Free Air 17.0 C/W 5.06 C/W 8.8 C/W 7.7 C/W 200 LFM 8.7 C/W 3.84 C/W 6.3 C/W 5.8 C/W 400 LFM 6.0 C/W 2.91 C/W 4.8 C/W 4.5 C/W 600 LFM 4.7 C/W 2.29 C/W 3.9 C/W 3.8 C/W 800 LFM 4.1 C/W 1.92 C/W 3.4 C/W 3.2 C/W 1,000 LFM 3.5 C/W 1.61 C/W 3.1 C/W 2.9 C/W The steps involved in selecting a heat sink / fan combination for forced convection are essentially the same as those followed for free convection, with the additional requirement that the heat sink and fan be matched to achieve desired heat sink-to-air thermal resistance. Attention must also be paid to proper channeling of fan airflow so that maximum utilization of its cooling capability is realized. Selection of a heat sink / fan combination involves the following three steps: 1. Determine maximum acceptable heat sink-to-air thermal resistance by following the first three steps of the heat sink selection procedure given in the Free Convection section. 2. Selection of a heat sink / fan combination requires that forced convection data for both the heat sink and fan be available. Forced convection characteristics for heat sinks define both heat sink-to-air thermal resistance and pressure drop through the heat sink as a function of airflow. Fan characteristics define airflow as a function of pressure drop. The intersection point of the airflow versus pressure curves for the fan and heat sink will define the operating airflow through the heat sink (Figure 5). The heat sink-to-air thermal resistance for this airflow may be read directly off the airflow versus resistance curve for the heat sink. Figure 5. Airflow vs. resistance Airflow (CFM) Heatsink Curve Operating Airflow Airflow (CFM) Fan Curve Pressure (in. H 2O) X Thermal Resistance at Operating Airflow Heatsink to Air Thermal Resistance ( C/Watt) AN:200 vicorpower.com Applications Engineering: Page 6

7 Finding and interpreting the operating point requires consideration of the following: Units of pressure drop are generally given in inches of water. Units of fan airflow are in cubic feet per minute (CFM). Occasionally metric units are used, but conversion is straightforward. Heat sink airflows may be given either in CFM or LFM (linear feet per minute). The conversion between LFM and CFM is dependent on the cross-sectional area through which air is flowing: CFM = LFM X Area The cross-sectional area between the fins is the area through which the total airflow must pass (Figure 6). Correct interpretation of heat sink data requires that only the airflow through this area be considered. Simply pointing a fan at a heat sink will clearly not result in all of the flow going through the cooling cross-section of the sink; some channeling of air is usually required to get the full benefit of fan output. The fan curves give output in CFM versus pressure drop. Fan pressure drop is the total of all drops encountered by the fan airflow. The heat sink, any ducting that is used, and air entry and exit channels all contribute to pressure drop. Pressure drop represents the work done by the fan in moving air through a region, so care should be taken to minimizeunproductive pressure losses. Ensure that air entry and exit locations and internal air channels are not unduly constricted, and avoid sharp turns in airflow paths. Figure 6. Heat sink cross section S Cooling Airflow is Air Which Flows Through the Shaded Cooling Cross-Sectional Area Area = (N - 1) x H x S H S = Fin Spacing H = Fin Height N = No. of Fins The thermal resistance that was determined by overlapping the fan and heat sinkcurves will represent an optimistic estimate since it assumes that all the fan output flows through the heat sink cooling cross section, and that all the pressure drop occurs along the heat sink. If the estimated thermal resistance is close to the minimum value determined in Step 1, then it is likely that a larger fan or different heat sink is required. This will not be a problem in most cases; relatively modest heat sinks and fans usually provide ample cooling. Careful channeling and ducting of airflow as a means of both maximizing flow through the cooling cross-section of the heat sink and minimizing extraneous flow of air around the sink is well worth the small extra design effort required. Every degree of improvement in baseplate temperature results in significant improvement in MTBF. If you are paying for a fan, you may as well leverage it for all that it is worth. 3. Steps 5 through 7 in the Free Convection section will complete the heat sink selection process. Select the fan / heat sink combination with the lowest thermal resistance consistent with cost and space constraints, calculate the estimated baseplate temperature and test to verify. AN:200 vicorpower.com Applications Engineering: Page 7

8 Definitions Tmax = maximum baseplate temperature (available from VI Brick data sheets) Ta = ambient temperature η = efficiency = P out P in (Available from VI Brick data sheets) Qbs = baseplate-to-heat sink thermal resistance (Available from VI Brick data sheets) Qsa = heatsink-to-air sink thermal resistance (Available from heat sink manufacture) Thermal Equations P diss = dissipated power = P 1 out ( η ) 1 CFM Airflow (LFM) = Area Maximum output power = T max T a Θ 1 sa ( η ) 1 Maximum thermal impedance = Max. ambient temp. = Temperature rise = Θ sa x P out T max T a 1 Pout( η ) 1 T 1 max Θ sa x P out ( η ) 1 1 ( η ) 1 Thermal drop = Θ 1 bm x P out ( η ) 1 AN:200 vicorpower.com Applications Engineering: Page 8

9 Typical Examples Example 1. Determine the maximum output power for a 300 W, VT048A320T009FP VTM module, no heat sink, delivering 32 V in 400 LFM at a maximum ambient temperature of 45 C. Maximum output power = T max = 100 C T a = 45 C Θ sa = 4.5 C/W η = 96% = (0.96) T max T a Θ 1 sa ( η ) 1 Maximum output power = ( ) = 293 W Example 2. Determine the maximum heat sink thermal impedance for a 330 W, FE175D480C033FP-00 AC Front End Module, with thermal pad, delivering 48V at 300W. Max. heat sink thermal impedance = Θ sa = T max T a 1 Pout( η ) 1 T max = 100 C Θ bs T a = 55 C P out = 300W Θ bs = 0.17 C/W η = 92% = (0.92) Max. heat sink thermal impedance = Θ sa = ( ) = 1.55 C/W AN:200 vicorpower.com Applications Engineering: Page 9

10 Thermal Curves Figure 7. Baseplate to air thermal impedance DC-DC module VI Brick DC-DC Øsa vs. Air Flow, No Heat Sink (Tbaseplate - Tambient) / Figure 8. Baseplate to air thermal impedance PRM module (Tbaseplate - Tambient) / VI Brick PRM Øsa vs. Air Flow, No Heat Sink Figure 9. Baseplate to air thermal impedance VTM /BCM module VI Brick VTM/BCM Øsa vs. Air Flow, No Heat Sink (Tbaseplate - Tambient) / AN:200 vicorpower.com Applications Engineering: Page 10

11 Thermal Curves (Cont.) Figure 10. Baseplate to air thermal Impedance VI Brick PFM module (no PCB contribution) Baseplate to Ambient Thermal Resistance ( C/W) VI Brick PFM Øsa vs. Air Flow, No Heat Sink Figure 11. Baseplate to air thermal Impedance AC Front End (no PCB contribution) VI Brick AC Front End Øsa vs. Air Flow, No Heat Sink (Tbaseplate - Tambient) / AN:200 vicorpower.com Applications Engineering: Page 11

12 AC Front End Heat Sink Thermal Impedance Data Table 2. Thermal impedance for AC Front End heat sinks AC Front End Part # " L Fins[a] (31,8 mm) Part # " L Fins (17,8 mm) Part # " T Fins[b] (31,8 mm) Part # " T Fins (17,8 mm) θsa θsa θsa θsa Free Air LFM LFM LFM LFM ,000 LFM [a] Longitudinal fins [b] Transverse fins Figure 12. Heat sink to air thermal impedance part # longitudinal fins (Theatsink - Tambient) / Heat Sink #38145 Øsa vs. Air Flow Figure 13. Heat sink to air thermal impedance part # longitudinal fins (Theatsink - Tambient) / Heat Sink #39068 Øsa vs. Air Flow 0.00 AN:200 vicorpower.com Applications Engineering: Page 12

13 AC Front End Heat Sink Thermal Impedance Data (Cont.) Figure 14. Heat sink to air thermal impedance part # transverse fins (Theatsink - Tambient) / Heat Sink #38146 Øsa vs. Air Flow Figure 15. Heat sink to air thermal impedance part # transverse fins (Theatsink - Tambient) / Heat Sink #39069 Øsa vs. Air Flow Please visit for the most up-to-date heat sink offerings. The Power Behind Performance Rev /13 vicorpower.com Applications Engineering: Page 13

Shrinking a power supply and the challenge to maintain high reliability.

Shrinking a power supply and the challenge to maintain high reliability. Application Note - AN1201 Shrinking a power supply and the challenge to maintain high reliability. Shane Callanan, Director of Applications Engineering, Excelsys Technologies considers the challenges associated

More information

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings zpero 1 The Effect of Forced Air Cooling on Heat Sink Thermal Ratings By Paul Bachman, Fellow Engineer & Ronnie Haiduk, Applications Engineer, Crydom, Inc. ABSTRACT A heat sink s ability to dissipate thermal

More information

EXTRUDED HEAT SINKS FOR POWER SEMICONDUCTORS

EXTRUDED HEAT SINKS FOR POWER SEMICONDUCTORS WTS001_p26-49 6/14/07 10:56 AM Page 45 EXTRUDED HEAT SINS FOR POWER S 621/623 SERIES Low-Profile for All Metal-Case Power Semiconductors TO-3 Footprint Thermal Performance at Typical Load Standard Dimensions

More information

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT? Data Bulletin April 2001 Raleigh, NC, USA Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW Variable frequency drives are available from manufacturers as enclosed engineered

More information

Everline Module Application Note: Round LED Module Thermal Management

Everline Module Application Note: Round LED Module Thermal Management Everline Module Application Note: Round LED Module Thermal Management PURPOSE: Use of proper thermal management is a critical element of Light Emitting Diode (LED) system design. The LED temperature directly

More information

VICOR WHITE PAPER. The Sine Amplitude Converter Topology Provides Superior Efficiency and Power Density in Intermediate Bus Architecture Applications

VICOR WHITE PAPER. The Sine Amplitude Converter Topology Provides Superior Efficiency and Power Density in Intermediate Bus Architecture Applications The Sine Amplitude Converter Topology Provides Superior Efficiency and Power Density in Intermediate Bus Architecture Applications Maurizio Salato, Applications Engineering, Vicor Corporation Contents

More information

Application Note AN-1057

Application Note AN-1057 Application Note AN-1057 Heatsink Characteristics Table of Contents Page Introduction...1 Maximization of Thermal Management...1 Heat Transfer Basics...1 Terms and Definitions...2 Modes of Heat Transfer...2

More information

Intel Atom Processor E3800 Product Family

Intel Atom Processor E3800 Product Family Intel Atom Processor E3800 Product Family Thermal Design Guide October 2013 Document Number: 329645-001 Legal Lines and Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS.

More information

THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks

THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks Abstract Shrinking thermal margins, driven by sophisticated but thermally

More information

Calculating Heat Loss by Mark Crombie, Chromalox

Calculating Heat Loss by Mark Crombie, Chromalox Calculating Heat Loss by Mark Crombie, Chromalox Posted: January 30, 2006 This article deals with the basic principles of heat transfer and the calculations used for pipes and vessels. By understanding

More information

How To Calculate Thermal Resistance On A Pb (Plastipo)

How To Calculate Thermal Resistance On A Pb (Plastipo) VISHAY BEYSCHLAG Resistive Products 1. INTRODUCTION Thermal management is becoming more important as the density of electronic components in modern printed circuit boards (PCBs), as well as the applied

More information

LDO03C/LDO06C/LDO10C

LDO03C/LDO06C/LDO10C NEW LDO03C/LDO06C/LDO10C A p p l i c a t i o n N o t e 1 8 6 1. Introduction 2 2. Models Features 2 3. General Description Electrical Description 2 Physical Construction 2 4. Features and Functions Wide

More information

Comparing naturally cooled horizontal baseplate heat sinks with vertical baseplate heat sinks

Comparing naturally cooled horizontal baseplate heat sinks with vertical baseplate heat sinks Comparing naturally cooled horizontal baseplate heat sinks with vertical baseplate heat sinks Keywords: heat sink heatsink fin array natural convection natural cooling free convection horizontal baseplate

More information

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout FPA Printed Circuit Board Layout Guidelines By Paul Yeaman Principal Product Line Engineer V I Chip Strategic Accounts Introduction Contents Page Introduction 1 The Importance of 1 Board Layout Low DC

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

AC-DC Converter Application Guidelines

AC-DC Converter Application Guidelines AC-DC Converter Application Guidelines 1. Foreword The following guidelines should be carefully read prior to converter use. Improper use may result in the risk of electric shock, damaging the converter,

More information

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction Module 1 : Conduction Lecture 5 : 1D conduction example problems. 2D conduction Objectives In this class: An example of optimization for insulation thickness is solved. The 1D conduction is considered

More information

An Assessment of Radiator Performance

An Assessment of Radiator Performance An Assessment of Radiator Performance By William Adams September 9, 2005 Table of contents 1. Test Equipment and Procedures...2 2. Radiator Descriptions...3 3. Performance Testing...4 a. Group 1: Single

More information

Thermal Mass Availability for Cooling Data Centers during Power Shutdown

Thermal Mass Availability for Cooling Data Centers during Power Shutdown 2010 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions (2010, vol 116, part 2). For personal use only. Additional reproduction,

More information

Natural Convection. Buoyancy force

Natural Convection. Buoyancy force Natural Convection In natural convection, the fluid motion occurs by natural means such as buoyancy. Since the fluid velocity associated with natural convection is relatively low, the heat transfer coefficient

More information

DirectFET TM - A Proprietary New Source Mounted Power Package for Board Mounted Power

DirectFET TM - A Proprietary New Source Mounted Power Package for Board Mounted Power TM - A Proprietary New Source Mounted Power Package for Board Mounted Power by Andrew Sawle, Martin Standing, Tim Sammon & Arthur Woodworth nternational Rectifier, Oxted, Surrey. England Abstract This

More information

Intel Quark SoC X1000

Intel Quark SoC X1000 Thermal and Mechanical Design Guide April 2014 Document Number: 330259-001 Legal Lines and Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR

More information

Detailed Design Review. P15611: Digital Microfluidics Packaging

Detailed Design Review. P15611: Digital Microfluidics Packaging Detailed Design Review P15611: Digital Microfluidics Packaging Presentation Summary - 1 Requirements/Test Plan Risk Assessment Individual Solutions System and Drawings Bill of Materials Schedule Questions/Discussion

More information

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product. COOLING FAN REQUIREMENTS CALCULATIONS Determining System Impedance Determining the actual airflow produced by a fan mounted in an enclosure is much more difficult than calculating the airflow required.

More information

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series. Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series. 1 To discuss the design challenges of LED systems we look at the individual system components. A basic

More information

Fan Basics and Selection Criteria (How to Use)

Fan Basics and Selection Criteria (How to Use) Feature: Understanding SANYO DENKI Products from Scratch Fan Basics and Selection Criteria (How to Use) Honami Osawa 1. Introduction In recent years, the importance of cooling technology has become even

More information

Application Note AN-1059. DirectFET Technology Thermal Model and Rating Calculator

Application Note AN-1059. DirectFET Technology Thermal Model and Rating Calculator Application Note AN-1059 DirectFET Technology Thermal Model and Rating Calculator Table of Contents Page Introduction... 2 Equivalent circuits... 3 Thermal resistance values... 3 Analysis... 3 Rating Calculator...

More information

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP PowerAmp Design COMPACT HIGH VOLTAGE OP AMP Rev G KEY FEATURES LOW COST SMALL SIZE 40mm SQUARE HIGH VOLTAGE 200 VOLTS HIGH OUTPUT CURRENT 10A PEAK 40 WATT DISSIPATION CAPABILITY 200V/µS SLEW RATE APPLICATIONS

More information

Surface Mount Technology cooling for high volumes applications by: Cesare Capriz Aavid Thermalloy via XXV Aprile 32 Cadriano (BO) ITALY

Surface Mount Technology cooling for high volumes applications by: Cesare Capriz Aavid Thermalloy via XXV Aprile 32 Cadriano (BO) ITALY Surface Mount Technology cooling for high volumes applications by: Cesare Capriz Aavid Thermalloy via XXV Aprile 32 Cadriano (BO) ITALY Abstract: The automotive technology is fast moving in integrating

More information

DC/DC power modules basics

DC/DC power modules basics DC/DC power modules basics Design Note 024 Ericsson Power Modules General Abstract This design note covers basic considerations for the use of on-board switch mode DC/DC power modules, also commonly known

More information

DC-DC Converter Module

DC-DC Converter Module 45 Features DC input range: 250-425V Input surge withstand: 500V for 100ms DC output: 24V Programmable output: 10 to 110% Regulation: ±0.2% no load to full load Efficiency: 88% Maximum operating temperature:

More information

Application Note TMA Series

Application Note TMA Series 1W, SIP, Single & Dual Output DC/DC Converters Features SIP Package with Industry Standard Pinout Package Dimension: 19.5 x 10.2 x 6.1 mm (0.77 x 0.4 x 0.24 ) 5V&12V Models 19.5 x 10.2 x 7.1 mm (0.77 x

More information

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE Vivek Khaire, Dr. Avijit Goswami Applied Thermal Technologies India 3rd Floor,C-Wing,Kapil Towers, Dr. Ambedkar Road, Pune- 411 1 Maharashtra,

More information

High Efficiency Battery Charger using Power Components [1]

High Efficiency Battery Charger using Power Components [1] application note TPB:101 High Efficiency Battery Charger using Power Components [1] Marco Panizza Senior Applications Engineer July 2006 Contents Page Introduction 1 A Unique Converter 1 Control Scheme

More information

STANDARD EXTRUDED HEAT SINKS

STANDARD EXTRUDED HEAT SINKS STANDARD EXTRUDED HEAT SINKS ABHA101 Weight: 0.4oz (11.34g) ABHA102 Weight: 0.5oz (14.17g) STANDARD EXTRUDED HEAT SINKS ABHA103 Weight: 0.2oz (5.57g) For use with DIPs and SRAMs ABHA104 Weight: 0.1oz (2.83g)

More information

Technology Corporation

Technology Corporation 1 White Paper Meeting The Increased Demand For Efficient Computer Room Cooling Server Cooling Problems: An Overview As microprocessors and other electronic components in servers grow more powerful, they

More information

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers Vapor Chambers A vapor chamber is a high-end thermal management device that can evenly dissipate heat from a small source to a large platform of area (see Figure 1). It has a similar construction and mechanism

More information

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.

More information

Low Voltage, Resistor Programmable Thermostatic Switch AD22105

Low Voltage, Resistor Programmable Thermostatic Switch AD22105 a Low Voltage, Resistor Programmable Thermostatic Switch AD22105 FEATURES User-Programmable Temperature Setpoint 2.0 C Setpoint Accuracy 4.0 C Preset Hysteresis Wide Supply Range (+2.7 V dc to +7.0 V dc)

More information

Accurate Air Flow Measurement in Electronics Cooling

Accurate Air Flow Measurement in Electronics Cooling Accurate Air Flow Measurement in Electronics Cooling Joachim Preiss, Raouf Ismail Cambridge AccuSense, Inc. E-mail: info@degreec.com Air is the most commonly used medium to remove heat from electronics

More information

Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card

Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card CASE STUDY Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card Challenge When GE Fanuc Intelligent Platforms, a leading

More information

MOSFET TECHNOLOGY ADVANCES DC-DC CONVERTER EFFICIENCY FOR PROCESSOR POWER

MOSFET TECHNOLOGY ADVANCES DC-DC CONVERTER EFFICIENCY FOR PROCESSOR POWER MOSFET TECHNOLOGY ADVANCES DC-DC CONVERTER EFFICIENCY FOR PROCESSOR POWER Naresh Thapar, R.Sodhi, K.Dierberger, G.Stojcic, C.Blake, and D.Kinzer International Rectifier Corporation El Segundo, CA 90245.

More information

3. Design Requirements

3. Design Requirements 3. Design Requirements Design Guide & Applications Manual SAFETY CONSIDERATIONS Fusing. Safety agency conditions of acceptability require that the module positive (+) Input terminal be fused and the baseplate

More information

650W Single Output Power Supply

650W Single Output Power Supply AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent

More information

Integration of a fin experiment into the undergraduate heat transfer laboratory

Integration of a fin experiment into the undergraduate heat transfer laboratory Integration of a fin experiment into the undergraduate heat transfer laboratory H. I. Abu-Mulaweh Mechanical Engineering Department, Purdue University at Fort Wayne, Fort Wayne, IN 46805, USA E-mail: mulaweh@engr.ipfw.edu

More information

Using Simulation to Improve Data Center Efficiency

Using Simulation to Improve Data Center Efficiency A WHITE PAPER FROM FUTURE FACILITIES INCORPORATED Using Simulation to Improve Data Center Efficiency Cooling Path Management for maximizing cooling system efficiency without sacrificing equipment resilience

More information

AS2815. 1.5A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

AS2815. 1.5A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response 1.5A Low Dropout oltage Regulator Adjustable & Fixed Output, Fast Response FEATURES Adjustable Output Down To 1.2 Fixed Output oltages 1.5, 2.5, 3.3, 5.0 Output Current of 1.5A Low Dropout oltage 1.1 Typ.

More information

In today s world of wireless communications

In today s world of wireless communications TUTORIAL RF CERAMIC CHIP CAPACITORS IN HIGH RF POWER APPLICATIONS Reprinted with permission of MICROWAVE JOURNAL from the April 2000 issue. 2000 Horizon House Publications, Inc. In today s world of wireless

More information

DSRQ - DSRSQ - DSRSQ-THERM

DSRQ - DSRSQ - DSRSQ-THERM DSRQ - DSRSQ - DSRSQ-THERM Specification item: Variable geometry diffuser on 597x597 mm panel developed for rooms with high ceilings where a long throw and a high induction ratio are required. Made up

More information

TEP 200WIR Series, 180 240 Watt

TEP 200WIR Series, 180 240 Watt TEP 200WIR Series, 180 240 Watt Features Chassis mount with screw terminal block Including EMI filter to meet EN 55022, class A Ultra wide 4:1 input voltage ranges 8.5 36, 16.5 75, 43 160 VDC EN 50155

More information

DC/DC Converter 9 to 18Vdc and 18 to 36Vdc and 36 to 75Vdc input, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

DC/DC Converter 9 to 18Vdc and 18 to 36Vdc and 36 to 75Vdc input, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output THN 20 Series Application Note DC/DC Converter 9 to 18Vdc and 18 to 36Vdc and 36 to 75Vdc input, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output Pending Applications Wireless

More information

Power Dissipation Considerations in High Precision Vishay Sfernice Thin Film Chips Resistors and Arrays (P, PRA etc.) (High Temperature Applications)

Power Dissipation Considerations in High Precision Vishay Sfernice Thin Film Chips Resistors and Arrays (P, PRA etc.) (High Temperature Applications) VISHAY SFERNICE Resistive Products Application Note ABSTRACT On our thin film chips resistors and arrays the main path for the heat, more than 90 %, is conduction through the body of the component, the

More information

Thermal Resistance, Power Dissipation and Current Rating for Ceramic and Porcelain Multilayer Capacitors

Thermal Resistance, Power Dissipation and Current Rating for Ceramic and Porcelain Multilayer Capacitors Thermal Resistance, Power Dissipation and Current Rating for Ceramic and Porcelain Multilayer Capacitors by F. M. Schaubauer and R. Blumkin American Technical Ceramics Reprinted from RF Design Magazine,

More information

Managing Heat Stress in Poultry

Managing Heat Stress in Poultry Managing Heat Stress in Poultry Amy E. Halls, Monogastric Nutritionist Shur-Gain, Nutreco Canada Inc. Heat stress has several serious and economical effects on poultry. In broilers and turkeys, it can

More information

Optimum fin spacing for fan-cooled heat sinks

Optimum fin spacing for fan-cooled heat sinks Optimum fin spacing for fan-cooled heat sinks Keywords: optimum fin spacing fan-cooled heat sink heatsink optimal fin pitch parallel plate fin array optimization forced air cooling fan curve pressure drop

More information

The Three Heat Transfer Modes in Reflow Soldering

The Three Heat Transfer Modes in Reflow Soldering Section 5: Reflow Oven Heat Transfer The Three Heat Transfer Modes in Reflow Soldering There are three different heating modes involved with most SMT reflow processes: conduction, convection, and infrared

More information

TGP-751 TGP-651. ThermoGenerator-Package (TGP) Thin Film Thermogenerator inside standard package. Preliminary Datasheet

TGP-751 TGP-651. ThermoGenerator-Package (TGP) Thin Film Thermogenerator inside standard package. Preliminary Datasheet TGP-751 TGP-651 (TGP) Thin Film Thermogenerator inside standard package Preliminary Datasheet Important Notices Please read carefully prior to use Micropelt Products are prototypes Micropelt supplies thermoelectric

More information

CCI HEAT PIPE DESIGN GUIDE

CCI HEAT PIPE DESIGN GUIDE CCI HEAT PIPE DESIGN GUIDE Rev: D01 Prepared by:cci RD01 Heat Pipe Team Date:27. June. 2006 *Contents Feature descriptions & Geometry limitation Test methodology descriptions Screen Mesh Groove Sintering

More information

Understanding How Cabinet Door Perforation Impacts Airflow by Travis North

Understanding How Cabinet Door Perforation Impacts Airflow by Travis North & design deployment The first step in determining the proper perforation for an application is to understand the airflow requirements of the equipment that will be used in the cabinet. Understanding How

More information

Heat Pipe Selection Revision 12/04/2001

Heat Pipe Selection Revision 12/04/2001 Heat Pipe Selection Revision 12/04/2001 Heat pipes are being used very often in particular applications when conventional cooling methods are not suitable. Once the need for heat pipe arises, the most

More information

POWER FORUM, BOLOGNA 20-09-2012

POWER FORUM, BOLOGNA 20-09-2012 POWER FORUM, BOLOGNA 20-09-2012 Convertitori DC/DC ad alta densità di potenza e bassa impedenza termica. Massimo GAVIOLI. Senior Field Application Engineer. Intersil SIMPLY SMARTER Challenges when Designing

More information

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES FREESTUDY HEAT TRANSFER TUTORIAL ADVANCED STUDIES This is the third tutorial in the series on heat transfer and covers some of the advanced theory of convection. The tutorials are designed to bring the

More information

Advanced Monolithic Systems

Advanced Monolithic Systems Advanced Monolithic Systems FEATURES Three Terminal Adjustable or Fixed oltages* 1.5, 1.8, 2.5, 2.85, 3.3 and 5. Output Current of 1A Operates Down to 1 Dropout Line Regulation:.2% Max. Load Regulation:.4%

More information

LM3940 1A Low Dropout Regulator for 5V to 3.3V Conversion

LM3940 1A Low Dropout Regulator for 5V to 3.3V Conversion 1A Low Dropout Regulator for 5V to 3.3V Conversion General Description The LM3940 is a 1A low dropout regulator designed to provide 3.3V from a 5V supply. The LM3940 is ideally suited for systems which

More information

Thermal runaway during blocking

Thermal runaway during blocking Application Note 5SYA 2045-01 Thermal runaway during blocking Since the beginning of semiconductor technology, thermal runaway has been a well-known effect. Thermal runaway occurs when the power dissipation

More information

Thermal Management of Electronic Devices used in Automotive Safety A DoE approach

Thermal Management of Electronic Devices used in Automotive Safety A DoE approach Thermal Management of Electronic Devices used in Automotive Safety A DoE approach Vinod Kumar, Vinay Somashekhar and Srivathsa Jagalur Autoliv India Private Limited, Bangalore, India Abstract: Electronic

More information

13.5-40.5GHz Frequency Multiplier. GaAs Monolithic Microwave IC. Output power (dbm) -10 -15 -20 -25 -30

13.5-40.5GHz Frequency Multiplier. GaAs Monolithic Microwave IC. Output power (dbm) -10 -15 -20 -25 -30 Output power (dbm) GaAs Monolithic Microwave IC Description The is a packaged monolithic time three multiplier which integrates input and output buffer. This circuit is a very versatile multiplier for

More information

Reliability of Air Moving Fans, and Their Impact on System Reliability. A White Paper from the Experts in Business-Critical Continuity TM

Reliability of Air Moving Fans, and Their Impact on System Reliability. A White Paper from the Experts in Business-Critical Continuity TM Reliability of Air Moving Fans, and Their Impact on System Reliability A White Paper from the Experts in Business-Critical Continuity TM Summary Air-moving fans are used to remove waste heat on all UPS

More information

LM1084 5A Low Dropout Positive Regulators

LM1084 5A Low Dropout Positive Regulators 5A Low Dropout Positive Regulators General Description The LM1084 is a series of low dropout voltage positive regulators with a maximum dropout of 1.5 at 5A of load current. It has the same pin-out as

More information

Using Simulation to Improve Data Center Efficiency

Using Simulation to Improve Data Center Efficiency A WHITE PAPER FROM FUTURE FACILITIES INCORPORATED Using Simulation to Improve Data Center Efficiency Cooling Path Management for maximizing cooling system efficiency without sacrificing equipment resilience

More information

Temperature-Aware Design of Printed Circuit Boards

Temperature-Aware Design of Printed Circuit Boards Temperature-Aware Design of Printed Circuit Boards Co-design of PCBs for electrical, mechanical and thermal engineers Based on EDA Design for Manufacturing Flows CDNLive 2007 Dirk Niemeier Support Manager

More information

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here. COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?

More information

Chapter 4: Transfer of Thermal Energy

Chapter 4: Transfer of Thermal Energy Chapter 4: Transfer of Thermal Energy Goals of Period 4 Section 4.1: To define temperature and thermal energy Section 4.2: To discuss three methods of thermal energy transfer. Section 4.3: To describe

More information

Optimization of electronic devices placement on printed circuit board

Optimization of electronic devices placement on printed circuit board Optimization of electronic devices placement on printed circuit board Abstract by M. Felczak, T.Wajman and B. Więcek Technical University of Łódź, Wólczańska 211/215, 90-924 Łódź, Poland Power densities

More information

978-1-4673-1965-2/12/$31.00 2012 IEEE 1488

978-1-4673-1965-2/12/$31.00 2012 IEEE 1488 Generic Thermal Analysis for Phone and Tablet Systems Siva P. Gurrum, Darvin R. Edwards, Thomas Marchand-Golder, Jotaro Akiyama, Satoshi Yokoya, Jean-Francois Drouard, Franck Dahan Texas Instruments, Inc.,

More information

The soot and scale problems

The soot and scale problems Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications

More information

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Lars Strong, P.E., Upsite Technologies, Inc. Kenneth G. Brill, Upsite Technologies, Inc. 505.798.0200

More information

Current and Temperature Ratings

Current and Temperature Ratings Document 361-1 Current and Temperature Ratings Introduction This application note describes: How to interpret Coilcraft inductor current and temperature ratings Our current ratings measurement method and

More information

CS4525 Power Calculator

CS4525 Power Calculator 1. OVERVIEW CS4525 Power Calculator The CS4525 Power Calculator provides many important application-specific performance numbers for the CS4525 based on user-supplied design parameters. The Power Calculator

More information

DC-DC Converters VI-200 VE-200

DC-DC Converters VI-200 VE-200 DC-DC Converters VI-200 VE-200 S C US C NRTL US 50 to 200 Watts Features Isolated output Up to 50 W/in 3 curus, ctüvus Up to 90% efficiency Size: 4.6" x 2.4" x 0.5" (116,8 x 61,0 x 12,7mm) Remote sense

More information

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2 CHAPTER 6 THERMAL DESIGN CONSIDERATIONS page Introduction 6-2 Thermal resistance 6-2 Junction temperature 6-2 Factors affecting 6-2 Thermal resistance test methods 6-3 Test procedure 6-3 Forced air factors

More information

Via dell' Industria, 25-31020 S. Vendemiano (TV) Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it e-mail Acquisti@elettrolab.

Via dell' Industria, 25-31020 S. Vendemiano (TV) Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it e-mail Acquisti@elettrolab. EDB300 Electronic Digital Ballast 300W DSP controlled Features: Electronic digital ballast suitable for 300W HID lamps Built-in PFC (pf>0.98 90-260 Vac full range). EMI filter inside. Compact shape, low

More information

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED www.analog.com www.hittite.com THIS PAGE INTENTIONALLY LEFT BLANK v2.71 HMC42ST8 / 42ST8E AMPLIFIER,.4-2.2

More information

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) Proceedings of the 2 nd International Conference on Current Trends in Engineering and Management ICCTEM -2014 ISSN 0976 6340 (Print)

More information

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal

More information

Series AMLDL-Z Up to 1000mA LED Driver

Series AMLDL-Z Up to 1000mA LED Driver FEATURES: Click on Series name for product info on aimtec.com Series Up to ma LED Driver Models Single output Model Input Voltage (V) Step Down DC/DC LED driver Operating Temperature range 4ºC to 85ºC

More information

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Scope The purpose of this paper is to provide specifying engineers, purchasers and users of evaporators in industrial refrigeration

More information

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract. TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION Abstract This application note describes the four quadrant mode of operation of a linear AC Power

More information

Thinking Outside the Box Server Design for Data Center Optimization

Thinking Outside the Box Server Design for Data Center Optimization Thinking Outside the Box Server Design for Data Center Optimization Marie Ross, Senior Applications Engineer Tom Gregory, Consultant Engineer October 2013 The benefits of analyzing thermal performance

More information

Current Limiting Power Resistors for High-Power LED Module Lighting Applications

Current Limiting Power Resistors for High-Power LED Module Lighting Applications Current Limiting Power Resistors for High-Power LED Module Lighting Applications PWR263 An ongoing trend toward miniaturization of virtually all electronics is accompanied by the demand for a reduction

More information

Benefits of Cold Aisle Containment During Cooling Failure

Benefits of Cold Aisle Containment During Cooling Failure Benefits of Cold Aisle Containment During Cooling Failure Introduction Data centers are mission-critical facilities that require constant operation because they are at the core of the customer-business

More information

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER International Journal of Advancements in Research & Technology, Volume 1, Issue2, July-2012 1 CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER ABSTRACT (1) Mr. Mainak Bhaumik M.E. (Thermal Engg.)

More information

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit) 000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,

More information

Power and Cooling for Ultra-High Density Racks and Blade Servers

Power and Cooling for Ultra-High Density Racks and Blade Servers Power and Cooling for Ultra-High Density Racks and Blade Servers White Paper #46 Introduction The Problem Average rack in a typical data center is under 2 kw Dense deployment of blade servers (10-20 kw

More information

Using NTC Temperature Sensors Integrated into Power Modules

Using NTC Temperature Sensors Integrated into Power Modules Using NTC Temperature Sensors Integrated into Power Modules Pierre-Laurent Doumergue R&D Engineer Advanced Power Technology Europe Chemin de Magret 33700 Mérignac, France Introduction Most APTE (Advanced

More information

Ampacity simulation of a high voltage cable to connecting off shore wind farms

Ampacity simulation of a high voltage cable to connecting off shore wind farms Ampacity simulation of a high voltage cable to connecting off shore wind farms Eva Pelster 1, Dr. David Wenger 1 1 Wenger Engineering GmbH, Einsteinstr. 55, 89077 Ulm, mail@wenger-engineering.com Abstract:

More information

Noise Control Solutions For Standby Power Generators

Noise Control Solutions For Standby Power Generators Noise Control Solutions For Standby Power Generators by David Gries NVH Applications Engineer E-A-R Specialty Composites Indianapolis, Indiana Introduction Over the past several years, there has been

More information

Voltage Output Temperature Sensor with Signal Conditioning AD22100

Voltage Output Temperature Sensor with Signal Conditioning AD22100 Voltage Output Temperature Sensor with Signal Conditioning AD22100 FEATURES 200 C temperature span Accuracy better than ±2% of full scale Linearity better than ±1% of full scale Temperature coefficient

More information

1150 hp motor design, electromagnetic and thermal analysis

1150 hp motor design, electromagnetic and thermal analysis 115 hp motor design, electromagnetic and thermal analysis Qasim Al Akayshee 1, and David A Staton 2 1 Mawdsley s Ltd., The Perry Centre, Davey Close, Waterwells, Gloucester GL2 4AD phone: +44 1452 888311

More information

Improved PFC Boost Choke using a Quasi-Planar Winding Configuration Dave Shonts Schott Corporation 1000 Parkers Lake Road Wayzata, MN 55391

Improved PFC Boost Choke using a Quasi-Planar Winding Configuration Dave Shonts Schott Corporation 1000 Parkers Lake Road Wayzata, MN 55391 Improved PFC Boost Choke using a Quasi-Planar Winding Configuration Dave Shonts Schott Corporation 1000 Parkers Lake Road Wayzata, MN 55391 Abstract- A novel approach to boost inductor design using a quasi-planar

More information