1 Remote control station WCM-FS 2.0 and solar controller WCM-SOL 1.0 home /
2
3 1 User instructions User guide Symbols Target group Guarantee and Liability Safety Permissible application Solar Safety measures Electrical connection Disposal Product description Type key Variations Solar supported water heating Solar supported DHW supply as well as heating support Independent control with WCM-FS and WCM-SOL Technical data Electrical data Approval data Ambient conditions Installation Remote control station WCM-FS (control module) Solar controller WCM-SOL (solar module) Electrical installation Remote control station WCM-FS (solar module) Solar controller WCM-SOL (solar module) Open housing cover Connecting solar controller WCM-SOL (solar module) Connection diagram solar controller WCM-SOL (solar module) Operating panel remote control station WCM-FS 2.0 (control module) Standard display Operating displays solar controller WCM-SOL (solar module) user level Menu structure end user level / La 3-78
4 6.5 Heating engineer level Menu structure heating engineer level Configuration WCM-SOL Set output VA Output test Set buffer switch differential Set buffer boost Summer / Winter change-over Set minimum volume flow Set maximum volume flow Collector frost protection Tyfocor Profitability threshold: Solar yield vs. pump flow ON threshold of solar pump Switching differential solar pump On Volume flow control strategy Switching differential solar pump Off Solar excess (SOL excess) Solar re-cooling Solar Prio HC Solar Prio DHW Information Buffer/de-couple Status display in the WCM-SOL solar controller (solar module) DTR Temperatures WHP Temperatures Collector circuit Solar yield counter Total solar yield Statistic Reset WCM-SOL Reconfiguring WCM-SOL for system alterations Manual function WCM-SOL Emergency operation WCM-SOL Reset WCM-FS Commissioning Prerequisite Set address on WCM-SOL Commissioning procedures on the WCM-FS remote control station Setting the language Set address assignment of the WCM-FS control station Sol procedure Application B Set number of collectors Set type of WHPSol OP Max OP Min / La 4-78
5 8 Information to optimise the operation of the system A Parameters Troubleshooting Error codes Protection functions Pump idle protection Frost protection collector circuit Frost protection Store/Buffer System frost protection Collector circuit overheat protection Thermal store overheat protection (procedure 1) Thermal store overheat protection (procedure 2) Technical documentation Sensor variables Key word index / La 5-78
6 1 User instructions Translation of original operating instructions 1 User instructions These installation and operating instructions form part of the unit and must be kept on site. 1.1 User guide Symbols DANGER Immediate danger with high risk. Non observance can lead to serious injury or death. WARNING CAUTION Danger with medium risk. Non observance can lead to environmental damage, serious injury or death. Danger with low risk. Non observance can cause damage to the equipment and injury to personnel. Important information. Requires direct action Result after an action Itemisation Range Target group These installation and operating instructions are intended for the operator and qualified personnel. They should be observed by all personnel working on the unit. Work on the unit must only be carried out by personnel who have the relevant training and instruction. Persons with limited physical, sensory or mental capabilities may only work on the unit if they are supervised or have been trained by an authorised person. Children must not play near or on the unit / La 6-78
7 1 User instructions 1.2 Guarantee and Liability Guarantee and liability claims for personal and equipment damage are excluded, if they can be attributed to one or more of the following causes: Non approved application of the remote control station, non observance of the operating instructions, continual operation despite a fault, repairs, which have been carried out incorrectly, the use of non original Weishaupt parts, acts of God / La 7-78
8 2 Safety 2 Safety 2.1 Permissible application Solar The remote control station WCM-FS 2.0 and the solar module WCM-SOL 1.0 home are suitable for control of a solar system. A heating system with up to 8 heating circuits (one direct heating circuit and 7 mixed heating circuits) and a Weishaupt condensing boiler can thus be supported by solar energy (heating and domestic hot water operation). This device is not intended for use by persons (including children) with reduced physical, sensory or mental capability or by persons lacking experience and/or knowledge, unless they are supervised by a person responsible for their safety or receive from this person instruction in how the device is used. Children should be supervised to ensure they do not play with the device. Any use other than that described above shall be deemed improper. Weishaupt cannot be held responsible for any damage resulting from such use. The risk of such misuse lies entirely with the user. Correct use also includes compliance with the installation and operating manual and all other documents, which are included in the delivery in addition to these instructions. The device described in these instructions conforms to the recognised level of technology and safety relevant regulations. Improper or inappropriate use could endanger the health and safety of the user or third party and impair the device function. 2.2 Safety measures Safety relevant fault conditions must be eliminated immediately. 2.3 Electrical connection For all work carried out on live parts: Observe the accident prevention instructions BGV A3 and adhere to local directives, tools in accordance with EN should be used. 2.4 Disposal The remote control station WCM-FS and the solar controller WCM-SOL must not be disposed of with household waste. Ensure the devices are disposed of in the correct manner. The units are subject to the Act Governing the Sales, Return and Environmentally Sound Disposal of Electrical and Electronic Equipment (Electrical and Electronic Equipment-WEEE). Therefore free removal is provided at communal waste collection facilities / La 8-78
9 3 Product description 3 Product description 3.1 Type key WCM Type: Weishaupt Condens Manager -FS Type: Remote control station 2.0 Construction WCM Type: Weishaupt Condens Manager -SOL Type: Solar module 1.0 Construction home Development stage Compatibility The compatibility of each WCM component to one another is shown in the table below. WCM-FS 1.0 WCM-FS 2.0 WCM-EM 1.0 WCM-EM 2.0 WCM-EM 2.1 WCM-SOL 1.0 WCM-KA 1.0 WCM-FS 1.0 C A A B B A* A* WCM-FS 2.0 C A A A A A A WCM-EM 1.0 A A C C B A A WCM-EM 2.0 A A C C B A A WCM-EM 2.1 B A C C A A A WCM-SOL 1.0 B A B B A D D D WCM-KA 1.0 A A A A A D D D WCM-KA 2.0 A A A A A D D D WCM-KA 2.0 A Full functionality A* Full functionality (from version WCM-FS 1.0 V196.27) B Compatible, the older component version limits the functionality C Can be used together in one system D Cannot be used in multiples/combined in one system / La 9-78
10 modul hydraul ic Installation and operating instruction 3 Product description 3.2 Variations Solar supported water heating In the system example, the solar controller is operated via the WCM-FS, address #1. The external sensor is connected to WTC address #A. DHW operation is carried out via WTC address #A. The solar controller is operated via the FS which, according to the address setting, has the functions DHW program, time master and circulation program. The following addresses are possible: Control centre#l, WTC-HC#1, WTC-HC#1 + EM-HC#2 and EM-HC#2. The WTC should be set to address #A. WTS-F B1 FS #1 T1 T T WTC-GW vers. W WCM-CPU#A WCM-Sol 1.0 home V T T T3 T4 T T PS V1 WHP-Sol EA M7 T F3 B3 T M7.1 T T2 WASol Legend: Note: FS: Remote control station WCM-FS 1. WCM-Sol: P317 = WASol B1: External temperature sensor 2. WCM-Sol: P801 = Bypass B3: DHW temperature sensor 3. WTC address: P12 = A M7: Circulation pump 4. WTC P13 = 6 (DHW circulation pump) M7.1: Bypass pump T1: Collector sensor T2: Thermal store sensor bottom T3: Solar flow sensor T4: Solar return sensor V1: FlowRotor PS: Solar pump F3: Thermostatic mixer valve / La 10-78
11 T modul hydraul ic Installation and operating instruction 3 Product description Solar supported DHW supply as well as heating support In the system example, the solar controller is operated via the WCM-FS, address #L or #2. The external sensor is connected to WTC address #A. DHW operation is carried out via WTC address #A. The solar controller is operated via the FS which, according to the address setting, has the functions DHW program, time master and circulation program. The following addresses are possible: Control centre#l, WTC-HC#1, WTC-HC#1 + EM-HC#2 and EM-HC#2. The WTC should be set to address #A. B1 T WTS-F FS #L, #2 WTC-GW vers. H EM #2 T B62 T1 T M42 M M22 WCM-CPU#A AB A M M3 B T T B3 B10 F3 M7 WCM-Sol 1.0 home V T T T3 T4 T T PS V1 WHP-Sol EA T B11 M7.1 T T2 WES 660 / 910 Legend: Note: FS: Remote control station WCM-FS 1. WCM-Sol: P317 = WES-C EM: Extension module WCM-EM 2. WCM-Sol: P801 = Bypass B1: External sensor 3. WTC address: P12 = A B3: DHW sensor 4. WTC P13 = 4 (3 way change-over valve) B10: Buffer sensor top 5. WTC P14 = 6 (DHW circulation pump) B11: Buffer sensor bottom B62: Supply sensor heating circuit 2 M3: DHW change-over valve M7: Circulation pump M22: Pump heating circuit 2 M42: Mixer valve heating circuit 2 M7.1: Bypass pump T1: Collector sensor T2: Thermal store sensor bottom T3: Solar flow sensor T4: Solar return sensor V1: FlowRotor PS: Solar pump F3: Thermostatic mixer valve / La 11-78
12 3 Product description Independent control with WCM-FS and WCM-SOL In the system example, the WCM-SOL is operated by the WCM-FS#2. The external sensor is connected to the WCM-EM-HC#2. The external temperature value is transmitted to all heating and DHW circuits connected via ebus. DHW operation is carried out via WCM-EM-DHW#8. A release control for an external heat exchanger can be switched via output VA 1. The operating conditions of the heat exchanger provided in the instructions from the manufacturer must be adhered to (if necessary by boiler controller supplied by others). The solar controller is operated via the FS which, according to the address setting, has the functions DHW program, time master and circulation program. The following addresses are possible: Control centre#l, WTC-HC#1, WTC-HC#1+EM-HC#2 and EM-HC#2. A zone control with a locally connected external sensor to additional extension modules WCM-EM is possible / La 12-78
13 T modul hydraul ic Installation and operating instruction 3 Product description B1 T WTS-F FS #2 EM-WW #8 EM #2 T B62 T1 T M42 M M22 AB A M M3 B T T B3 B10 F3 M7 WCM-Sol 1.0 home V T T T3 T4 T T PS V1 WHP-Sol EA T B11 T T2 WES 660 / 910 Legend: Note: FS: Remote control station WCM-FS 1. WCM-Sol: P317 = WES-C EM: Extension module WCM-EM 2. WCM-Sol: P801 = ReleaseWEZ B1: External sensor B3: DHW sensor B10: Buffer sensor top B11: Buffer sensor bottom B62: Supply sensor heating circuit 2 M3: DHW change-over valve M7: Circulation pump M22: Pump heating circuit 2 M42: Mixer valve heating circuit 2 T1: Collector sensor T2: Thermal store sensor bottom T3: Solar flow sensor T4: Solar return sensor V1: FlowRotor PS: Solar pump F3: Thermostatic mixer valve / La 13-78
14 3 Product description 3.3 Technical data Electrical data WCM-FS WCM-SOL Supply voltage / frequency 230 V/50 Hz Max. consumption 5 VA Max. prefusing 16 A Internal unit fuse 6.3 A Type of protection IP 31 Protection class I I (to EN 60730) I (to EN 60730) Nominal current output M1 max. 5 A* / ** Nominal current output VA1 max. 2 A * for electronic high efficiency pumps max 2 Ampere. Separate relay required for greater power consumptions. ** Current consumption of output M1 and voltage supply output must not exceed 5A Approval data Unit tested to EN Ambient conditions Temperature in operation 0 C 50 C Temperature during transport / storage C relative humidity max. 80 %, no dew point / La 14-78
15 4 Installation 4 Installation 4.1 Remote control station WCM-FS (control module) The room sensor integrated into the remote control station must not be influenced by: additional temperature control in the same room (radiator thermostats), other heat sources (direct sun light, chimney etc.). Install the remote control station to an inside wall on the opposite side to radiators. Fitting the wall bracket Fix wall bracket to wall. Connect wiring (see Ch. 5.1). Clip remote control unit into the wall bracket. modul control / La 15-78
16 4 Installation 4.2 Solar controller WCM-SOL (solar module) Fit cap type rail to the wall using suitable fixing material. Push in locking device 1. Connect extension module to cap type rail. Connect cables (see Ch. 5.2). Close housing cover / La 16-78
17 5 Electrical installation 5 Electrical installation 5.1 Remote control station WCM-FS (solar module) Connect electrical cable to ebus terminal 1 and 2. Ensure correct polarity of the ebus. An external room sensor can be fitted to terminals 5 and 6 if required (accessory). Cable cross section ebus Max. length 1.5 mm² 1260 m 0.5 mm² 420 m Generally, the use of screened electrical wiring is recommended. 5.2 Solar controller WCM-SOL (solar module) Open housing cover Lightly push down lug with screwdriver. Remove housing cover / La 17-78
18 230V L N L MF A1 H1 N M FA1 MM1 N 230V L N L N MF A1 MM1 N 230V L N L MF A1 H1 N 230V L N M FA1 L MF A1 H1 N MM1 N N MM1 230V L N L MF A1 H1 N MM1 N Installation and operating instruction 5 Electrical installation Connecting solar controller WCM-SOL (solar module) H1 L N H1 L N MM1 MM1 H1 H1 L N M FA1 H1 L N M FA1 H1 L N M FA1 MM1 MM1 MM1 Screened cables The ebus and any additional sensors can be connected via the screen plate. Ensure correct polarity of the ebus / La 18-78
19 5 Electrical installation Connection diagram solar controller WCM-SOL (solar module) WCM-Sol V L N 230V L N L M1 N VA1 1 2 E D C BA F ebus + B10 1 M B11 1 M T1 1 M T2 T3 1 M 1 M 1 M Flow T4 V P M 1 M F11 16A M 1~ PWM L N PE Mains 230V 1/N/PE 50Hz M1 VA1 V1 T4 B10 B11 T1 T2 T3 Plug Colour Connection Remarks 230 V black Supply voltage input 230 V AC/50 Hz 230 V grey Supply voltage output 230 V AC/50 Hz M1 white Relay output solar pump 230 V AC/ 50 Hz max. 5A (electronic pumps max. 2A) VA1 brown Potential free output 230 V AC max. 2A Protected by internal fuse Switched output solar pump Configuration-dependent output FlowRotor brown Pole V WHP Sol return sensor with turbine sensor white Pole P "FlowRotor" green Pole M T4 brown Pole 1 NTC-5k (STF 222) C white Pole M ebus light blue ebus connection B10 white Temperature sensor buffer top, NTC 5k Ohm B11 white Temperature sensor buffer bottom, NTC 5k Ohm T1 grey Temperature sensor collector sensor, NTC 5k Ohm T2 grey Temperature sensor reference temperature, NTC 5k Ohm T3 grey Temperature sensor collector supply, NTC 5k Ohm NTC-5k (STF 222) C NTC5k (STF 225) C NTC-5k (STF 222) C blue PWM control Modulation of heating circuit pump speed control / La 19-78
20 6.1 Operating panel remote control station WCM-FS 2.0 (control module) modul control 1 Dial knob Navigation through levels and parameters, change values, switch on illumination. 2 Function keys 1 4 Used to activate functions. 3 Presence and absence key Used for short term interruption or extension of the heating program. 4 Menu key Used to activate or exit end user level. Used to access or exit heating engineer level / La 20-78
21 6.2 Standard display Factory presetting Display of allocated factory pre-settings (standard). 1 Mon 21.May 07 19:20 HC i Room temp 20.0 C Heating program 1 1 ebus address, weekday, date, time 2 Symbol DHW heating 3 Information (Time program bar, status, external temperature, DHW temperature) 4 Current room temperature, if applicable current supply temperature 5 Type of operation with symbol Symbols for type of operation Normal operation Night setback operation Summer (DHW operation only) A Standby Automatic adaption / La 21-78
22 6.3 Operating displays solar controller WCM-SOL (solar module) WCM-SOL display Display status Meaning Mains LED ON Mains LED OFF Mains LED flashing 50 % ON, 50 % OFF All LED's flashing LED's turn on in sequence Mains voltage applied No mains voltage applied Mains voltage applied, fault condition (e.g. sensor failure) ebus address A set, after 10 seconds standard values are loaded (Reset) Progress of loading process for standard values when resetting the WCM-SOL ebus LED flashing50 % ON, 50 % OFF ebus LED flashes irregularly 5 % ON, 20 % OFF 5 % ON, 70 % OFF ebus LED continually OFF ebus LED continually ON ebus LED flashing50 % ON, 50 % OFF Pump LED ON Start phase of unit Unit address is set correctly, Bus connection is made, Bus supply is correct BUS open circuit, no BUS connection or BUS is under-supplied BUS is overloaded ebus voltage > 100 ma Incorrect ebus address set Relay output solar pump M1 connected Contact LED ON Relay output variable output VA1 connected ebus LED and Mains LED flashing ebus address F set, manual operation active Error LED flashes Display of error via error code on WCM-FS / La 22-78
23 6.4 user level Menu structure end user level Menu points and parameters are hidden or displayed depending to the scope of the system. Solar specific menu points and parameter are displayed on the FS which, according to the address setting, has the functions DHW program, time master and circulation program. The following addresses are possible: Control centre#l, WTC-HC#1, WTC-HC#1 + EM-HC#2 and EM-HC#2. Menu point Parameters Description Factory presetting Level info 001 External max 002 External min 003 Yield counter 004 Total yield 005 Statistic Remote control 101 Room sensor corr 0.0K 102 Contrast Illumination 30 Settings#1 112 Normal room temp 21.5 C 113 Setback room temp 16.0 C 114 Acceptance room Off 115 Normal supply setpoint 75.0 C 116 Setback supply setpoint 45.0 C 117 Gradient 118 Room frost temp 10.0 C 119 Su/Wi change 20.0 C Settings#2 121 Normal supply setpoint 75.0 C 122 Setback supply setpoint 45.0 C 123 Gradient Su/Wi change 20.0 C DHW 132 Normal DHW setpoint 50.0 C 133 Setback DHW setpoint 40.0 C 134 Acceptance DHW Off Holiday 141 Duration 142 Temp level Frost Time-Date 151 Date 152 Time 153 Summertime start 25.Mar 154 Summertime end 25.Oct Set / La 23-78
24 Menu point Parameters Description Factory presetting Time program Heating program 1 Heating program 2 Heating program Advance #2 Off DHW program Circ. program Access HC without FS new config List of all WCM-EM s without WCM-FS assigned EM-HC#2 or EM-DHW#2 EM-HC#8 or EM-DHW#8 Set / La 24-78
25 6.5 Heating engineer level Activate heating engineer level Press and hold menu key for 3 seconds. Heating engineer level is displayed. Heating engineer 01 Commissioning System info Heating circuit 1 Page number 2 Heating engineer level 3 Function key for menu selection Display further pages Turn the dial knob. Further pages of the menu are displayed. - + Heating engineer 01 Commissioning System info Heating circuit Heating engineer 02 DHW Access HC without FS Selecting a menu Select menu and press the relevant function key. Menu is displayed. Heating engineer 02 DHW Access HC without FS DHW 01 DHW maximum 60.0 C Legion funct Antileg setp temp 60.0 C / La 25-78
26 Selecting and setting parameters Select parameter and press the relevant function key. Parameter is displayed. Make a selection using the dial knob and save setting with function key OK. DHW 01 DHW maximum 60.0 C Legion funct Antileg setp temp 60.0 C DHW maximum C 50.0 C C Standard OK Resetting parameters to factory presetting Press function key Standard. Factory presetting is displayed. Press function key OK. Factory presetting is saved. DHW maximum C 50.0 C C Standard OK Exit heating engineer level Press function key repeatedly or briefly press menu key. Standard display appears / La 26-78
27 6.5.1 Menu structure heating engineer level Menu points and parameters are hidden or displayed depending to the scope of the system. Solar specific menu points and parameter are displayed on the FS which, according to the address setting, has the functions DHW program, time master and circulation program. The following addresses are possible: Control centre#l, WTC-HC#1, WTC-HC#1 + EM-HC#2 and EM-HC#2. Menu point Parameter Description Factory presetting Commissioning 311 Language German 313 HC-Type#1 8 Universal 314 HC-Type#2 Universal 315 Type of control#1 8 External 316 Type of control#2 External 317 Sol procedure WASol 318 Application B3 CPU/KA 319 Collector field Type WHPSol 20-7EA OP Max 322 OP Min System info 331 External current 332 Config WTC-G 333 Config Sol 334 Config user 335 Config FS 336 Config EM dampened mixed 337 Setpoint temp system 338 Error history 339 Version WCM-FS 340 Version WTC 341 Version EM-HC Heating circuit Extension module #2 Settings#1 Settings#2 Control behaviour Heating circuit info / La 27-78
28 Menu point Parameter Description Factory presetting DHW P601 DHW maximum 60 C Please refer to Manual Remote control station WCM-FS 2.0 and extension module WCM-EM 2.1 for the menu structure of the WCM-EM. Solar Inputs/outputs P801 Output VA1 Lockout Access HC without FS Buffer/de-couple P802 Output test P821 Buffer switch diff P822 Buffer boost P823 P2/P1 T-change 2K 1K Off Collector P841 Min sup. flow 0.6l/min P842 Max sup. flow P843 Collector Frost 15.0l/min -12 C P844 Tyfocor 30% P845 P min a collector 20W DT controller P861 Min collector 20 C P862 Switch diff ON P863 Control differential Switch diff OFF 7K 12K Energy management P881 Sol excess 70 C Info Solar P882 re-cooling P883 Solar prio HC P884 Solar Prio DHW P901 Buffer/de-couple P902 Status DTR P903 DTR temperatures P904 WHP temperatures P905 Collector circuit P906 Yield counter P907 Total yield P908 Statistic new config List of all WCM-EM s without WCM-FS assigned on EM-HC#2 or EM-DHW#2 EM-HC#8 or EM-DHW#8 4K Off Off Off / La 28-78
29 6.5.2 Configuration WCM-SOL This parameter is used to transfer the configuration information from the WCM-SOL to the WCM-FS. Control variation Buffer 1 Control with one buffer sensor B10 Buffer 2 Control with two buffer sensors B10+B11 De-couple Control of hydraulic de-couple with B11 Collector circuit sensor T1 T2 Sensor T1 T2 of collector circuit WHPSol EA sensor T3 T4 Sensor T3 T4 of pump assembly Activate heating engineer level (see Ch. 6.5). Press function key System info. Menu System info is displayed. Press function key Config SOL. Parameter Config SOL is displayed. Check configuration displayed. If the configuration is not the same, press function key New. The message search config appears briefly, then the current configuration is displayed. Save new configuration with OK. Heating engineer 01 Commissioning System info Heating circuit System info 01 External Config WTC-G 25#A Config Sol - + Config Sol 333 Buffer 2 T1 T2 New T3 T4 OK / La 29-78
30 6.5.3 Set output VA1 Assignment of variable function of output VA1. Setting range VA1 Lockout ReleaseWEZ Bypass P2/P1 Excess Solar Prio Fault message lockout to WCM-SOL 1.0 home Release contact for external heat exchanger Bypass pump operating during Legionella disinfection (complete thermal store disinfection) and re-cooling function (see Ch ) Switching procedure with activated control variation P1 (see Ch ) Switching procedure with activated status Excess (see Ch ) Switching procedure with activated status Solar Prio HC (see Ch ) Solar Prio DHW (see Ch ) Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Press function key Input/Output. Press function key Output VA1. Menu Output VA1 is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 01 Inputs/outputs Buffer/de-couple Collector Inputs/outputs 01 Output VA1 Output test Lockout - + Output VA1 801 Lockout Standard OK / La 30-78
31 6.5.4 Output test Testing the consumers connected to VA1 and M1, using a temporary manual switching process. Setting range VA1 On/Off Setting range M1 Off/--% Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Press function key Input/Output. Press function key Output test. Parameter Output test is displayed. Use function key to switch on/off. Set required value using dial knob and function keys. Check if a volume flow is generated when the pump is running. Solar 01 Input/Output Buffer/de-couple Collector Input/Output 01 Output VA1 Output test Lockout - + Output test 802 VA1 Off M1 Off V 0.00 l/h On Exit the parameter by pressing function key 1 () or by briefly pressing the menu key. The output test is terminated by exiting the parameter. Check pump function / FlowRotor. Switch on solar pump M1 via output test Observe LED on FlowRotor relative to pump activation Compare volume flow shown in P802 with OPmin / OPmax / La 31-78
32 6.5.5 Set buffer switch differential The parameter is only displayed at the activated control variations buffer 1, buffer 2 and de-couple control (de-couple). Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Press function key Buffer/De-couple. Press function key Buffer switch diff. Parameter Buffer switch diff is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 01 Input/Output Buffer/De-couple Collector Buffer/De-couple 02 Buffer switch diff 2.0K Buffer boost 1.0K P2/P1 T-change-over Off - + Buffer switch diff K 1.0K - 7.0K Standard OK / La 32-78
33 6.5.6 Set buffer boost The parameter is only displayed at the activated control variations buffer 1, buffer 2 and de-couple control (de-couple). Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Press function key Buffer/De-couple. Press function key Buffer boost. Parameter Buffer boost is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 01 Input/Output Buffer/De-couple Collector Buffer/De-couple 02 Buffer switch diff 2.0K Buffer boost 1.0K P2/P1 T-change-over Off - + Buffer boost K 0.0K K Standard OK / La 33-78
34 6.5.7 Summer / Winter change-over If the average external temperature value exceeds the temperature limit set, reloading is carried out according to buffer control variation P1. This automatically reduces the buffer volume to be heated. In return more buffer volume is provided for solar loading. Parameter is only displayed when control variation P2 (sensor B10/B11) is recognised and an external sensor is fitted. Parameter setting is based on external temperature. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Summer: (External temperature has exceeded the parameter setting) The WCM-SOL solar controller provides optimum buffering of solar heat. The buffer control strategy controls only with the temperature sensor B10 +/- buffer switch differential. This means more usable buffer volume remains for solar yield. Winter: (External temperature falls below the parameter setting) The WCM-SOL solar controller feeds in the solar yield. The buffer control strategy controls with the existing temperature sensors B10 and B11 to heat a defined area in the buffer store, thus minimising rapid cycling of the burner. Press function key Buffer/De-couple. Press function key Solar. Menu Solar is displayed. Press function key Buffer/De-couple. Press function key P2/P1 T-change-over. Parameter P2/P1 T-change-over is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 01 Input/Output Buffer/De-couple Collector Buffer/De-couple 02 Buffer switch diff 2.0K Buffer boost 1.0K P2/P1 T-change-over Off - + P2/P1 T-change-over 823 Off --;4.0 C C Standard OK / La 34-78
35 6.5.8 Set minimum volume flow Minimum volume flow in the collector circuit. An increase of the volume flow in the collector circuit may be necessary with high pressure losses in the collector circuit or viscous medium. This can be tested using parameter OP min in the start-up menu. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Press function key Collector. Press function key Min.V.Flow. Parameter Min.V.Flow is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 01 Input/Output Buffer/De-couple Collector Collector 01 Min.V.Flow 0.6l/min Max.V.Flow 15.0l/min Collector Frost C - + Min.V.Flow l/min 0.6l/min- 15.0l/min Standard OK / La 35-78
36 6.5.9 Set maximum volume flow By limiting the volume flow, electrical energy can be saved during high yield phases. C l max h min 0 h 1 Actual collector value T1 2 Collector setpoint value 3 Actual DHW value T2 4 Potential savings To limit the maximum volume flow, the nominal volume flow of the system at average temperature must first be determined (see table). The hydraulic design data of the collector must be observed. The system specific nominal volume flow of the collector manufacturer must not exceed the value set in P321 OP Max. If it does, the system design is flawed. Example Solar system (Weishaupt solar system WTS-F2) Collector type: WTS-F2 Number of collectors: 3 Average temperature (assumed): 50 C Nominal volume flow from table = 3.50 l/min (1 (1 The value determined must not be greater than the maximum operating point set in P321. average temperature Collector type WTS-F1 Number of collectors Nominal volume flow (l/min) Collector type WTS-F2 Number of collectors C C C C C C C / La 36-78
37 Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Press function key Collector. Press function key Max.V.Flow. Parameter Max.V.Flow is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 01 Input/Output Buffer/De-couple Collector Collector 01 Min.V.Flow 0.6l/min Max.V.Flow 15.0l/min Collector Frost C - + Max.V.Flow l/min 0.6l/min l/min Standard OK / La 37-78
38 Collector frost protection Temperature setting for frost protection of the collector circuit. Depending on the frost resistance of the medium. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Press function key Collector. Press function key Collector Frost. Parameter Collector Frost is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 01 Input/Output Buffer/De-couple Collector Collector 01 Min.V.Flow 0.6l/min Max.V.Flow 15.0l/min Collector Frost C - + Collector Frost C C C Standard OK Collector Frost is pre-assigned depending on the setting in P844 Tyfocor / La 38-78
39 Tyfocor Selection of Tyfocor concentration The parameter is used to define the correction factor of the heat quantity calculation and to preset the frost protection temperature. Settings 30%/45% Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Press function key Collector. Use dial knob to move to the second menu level. Press function key Tyfocor. Parameter Tyfocor is displayed. Select the value required using the dial knob. Confirm with function key OK. Solar 01 Input/Output Buffer/De-couple Collector Collector 02 Tyfocor 45 % P Min a collector 20 W - + Tyfocor % Standard OK By setting the parameter, P843 (Frost protection) is automatically preset. P844 P843 45% -25 C 30% -12 C / La 39-78
40 Profitability threshold: Solar yield vs. pump flow If the capacity limit value is not maintained, the solar pump is switched of. The capacity limit value set is based on the capacity of each collector. Settings W Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Press function key Collector. Use dial knob to move to the second menu level. Press function key P Min a collector. Parameter P Min a collector is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 01 Input/Output Buffer/De-couple Collector Collector 02 Tyfocor 30 % P Min a collector 20 W - + P Min a collector W Standard OK / La 40-78
41 ON threshold of solar pump Minimum collector temperature for the release of the solar pump. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key DT controller. Press function key Min collector. Parameter Min collector is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 02 DT controller Energy management Info Solar DT-Regler 01 Min collector 20.0 C Switch diff ON 7.0K Control diff 12.0K - + Min collector C 0.0 C C Standard OK / La 41-78
42 Switching differential solar pump On Differential temperature by which the collector temperature T1 must have exceeded the reference temperature T2. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key DT controller. Press function key Switch diff ON. Parameter Switch diff ON is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 02 DT controller Energy management Info Solar DT controller 01 Min collector 20.0 C Switch diff ON 7.0K Control diff 12.0K - + Switch diff ON K 4.0K K Standard OK / La 42-78
43 Volume flow control strategy Compensated temperature differential between collector flow temperature (T3) and reference temperature (T2). Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key DT controller. Press function key Control diff. Parameter Control diff is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 02 DT controller Energy management Info Solar DT controller 01 Min collector 20.0 C Switch diff ON 7.0K Control diff 12.0K - + Control diff K 1.0K K Standard OK / La 43-78
44 Switching differential solar pump Off If the minimum temperature differential between collector flow temperature (T3) and collector return temperature (T4) is not maintained, the solar pump is switched off. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key DT controller. Use dial knob to move to the second menu level. Press function key Switch diff OFF. Parameter Switch diff OFF is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 02 DT controller Energy management Info Solar DT controller 02 Switch diff OFF 4.0K - + Switch diff OFF K 1.0K - 7.0K Standard OK / La 44-78
45 Solar excess (SOL excess) When a defined thermal store temperature has been reached (status excess) the controller can supply excess solar heat to heating circuits, such as radiators in the basement. Reactions of the heating circuits can be defined separately in menu Heating circuit P431/471 SOL Yield HC. The reactions of the DHW load circuits can be defined separately in menu DHW P611 SOL Yield DHW. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Energy management. Press function key Sol excess. Parameter Sol excess is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 02 DT controller Energy management Info Solar Energy management 01 Sol excess 70.0 C Re-cooling Off Solar Prio HC Off - + Sol excess C 30.0 C C Standard OK The display of the parameters is dependent on the diagram P317 Sol procedure = WES-C / La 45-78
46 Example: In the following example the relationship between the adjustable temperature limit value "Sol excess" and the reaction of the heating and DHW load circuits to status "Excess" is shown. The reaction of the heating circuit and/or DHW load circuit to the status message Excess temp is the same as to the status message Excess. For an explanation of status message Excess temp see (see Ch. 10.7). WCM-Sol 1.0 settings P881 Sol excess 73 C WCM-EM-HC (heating circuit) settings P431 SOL yield HC Max. supply with excess with excess temp WCM-EM-DHW (DHW load circuit) settings P611 SOL Yield DHW DHW maximum with excess with excess temp Function WES-C: B10 > 73 C: Heating circuit reaction: DHW load circuit reaction: Function WES-C: B10 < 63 C Heating circuit reaction: DHW load circuit reaction: Status message Excess to all HC and DHW load circuits. The heating circuit is operated at Max flow. The DHW load circuit is operated at DHW maximum. Status message Excess is withdrawn. The heating circuit operates as prior to status Excess. The DHW load circuit operates as prior to status Excess / La 46-78
47 Solar re-cooling Need-based cooling of the thermal store via the collector circuit between 0:00 hours and 04:00 hrs. To prevent stagnation after previous overheating, a thermal store can be cooled during the night via the collector circuit. During re-cooling the thermal store can be circulated via a bypass pump. For this purpose the bypass pump should be connected to output VA1 and the setting Bypass should be selected in parameter Output VA Settings for solar re-cooling Off/On Activate heating engineer level (see Ch. 6.5). Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Energy management. Press function key Re-cooling. Parameter Re-cooling is displayed. Select the value required using the dial knob. Confirm with function key OK. Solar 02 DT controller Energy management Info Solar Energy management 01 Sol excess 70.0 C Re-cooling Off Solar Prio HC Off - + Re-cooling 882 Off Off - On Standard OK / La 47-78
48 Solar Prio HC During periods of increased solar yield, e.g. during an Autumn morning, the WCM- SOL solar controller proactively reduces the heat supplied by the conventional heating system, thus saving valuable fossil fuels. The reactions of the heating circuits can be defined separately in P114 Acceptance Room. The parameter is only displayed, if P317 SOL procedure is set to WES-C. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Energy management. Press function key Solar Prio HC. Parameter Solar Prio HC is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 02 DT controller Energy management Info Solar Energy management 01 Sol excess 70.0 C Re-cooling Off Solar Prio HC Off - + Solar Prio HC 883 Off --; 0.5 kw kw Standard OK / La 48-78
49 Example: In the following example the relationship between the adjustable yield limit Solar Prio HC and the reaction of the heating circuits to the status message Solar Prio HC is shown. Solar controller settings: P883 Solar prio HC 3kW FS (heating circuit) settings: P112 Normal room temp 22 C P114 Acceptance Room 2K Function: damped solar yield > 3kW Status message Solar Prio HC to all heating circuits The controller continues to try to achieve the room temperature setpoint of 22 C. Actual room temperature > 20 C P112 - P114 Actual room temperature < 20 C P112 - P114 Suppression of release for heating operation to the WTC Release of heating operation to the WTC If P114 Acceptance Room is set to Off, there will be no reaction from the heating circuit to status message Solar Prio HC / La 49-78
50 Solar Prio DHW During periods of increased solar yield, e.g. during an Autumn morning, the WCM- SOL solar controller proactively reduces the heat supplied by the conventional heating system, thus saving valuable fossil fuels. The reactions of the DHW load circuits can be defined separately in P134 Acceptance DHW. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Energy management. Use dial knob to move to the second menu level. Press function key Solar Prio DHW. Parameter Solar Prio DHW is displayed. Set required value using the dial knob. Confirm with function key OK. Solar 02 DT controller Energy management Info Solar Energy management 02 Solar Prio DHW Off - + Solar Prio DHW 884 Off --; 0.5 kw kw Standard OK / La 50-78
51 Example: In the following example the relationship between the adjustable yield limit Solar Prio DHW and the reaction of the DHW load circuits to the status message Solar Prio DHW is shown. Solar controller settings: P884 Solar prio DHW 3kW FS (DHW load circuit) settings: P132 Normal DHW setpoint 50 C P134 Acceptance DHW 12K Function: damped solar yield > 3kW Actual DHW temperature > 38 C P132 - P134 Actual DHW temperature < 38 C P132 - P134 Status message Solar Prio DHW to all DHW load circuits Suppression of release for DHW operation to the WTC Release of DHW operation to the WTC If P134 Acceptance DHW is set to Off, there will be no reaction from the DHW load circuit to status message Solar Prio DHW / La 51-78
52 6.6 Information Buffer/de-couple Display of the buffer or de-couple temperature and the current control variation of the buffer. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Info Solar. Press function key Buffer/De-couple. Parameter Buffer/De-couple is displayed. Solar 02 DT controller Energy management Info Solar Info Solar 01 Buffer/De-couple Status DTR DTR temperatures - + Buffer/De-couple 901 B C B C P2->P1 Off / La 52-78
53 6.6.2 Status display in the WCM-SOL solar controller (solar module) Display of the current operational condition of the WCM-SOL and the heating and DHW load circuits. Activate heating engineer level (see Ch. 6.5). Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Info Solar. Press function key Status DTR. Parameter Status DTR is displayed. Solar 02 DT controller Energy management Info Solar Info Solar 01 Buffer/De-couple Status DTR DTR temperatures - + Status DTR 902 Off HC: Excess DHW: Excess Status WCM-Sol Meaning Off No solar energy yield Stabilisation Solar energy yield: Stabilisation phase Activated following solar pump start-up, until heat is present at the collector flow sensor. Control Solar energy yield: DTR T3-T4 Ch Special Solar energy yield: DTR special phase T1-T4 Control strategy change-over to collector temperature (T1) and collector return temperature (T4). Stagnat Stagnation: The thermal store has excess temperature Cool Re-cooling via collector circuit Ch and Frost Collector frost protection Ch and Manual Solar controller in manual function Ch. 6.9 Emergency Solar controller in emergency operation Ch CK-Protect Collector protection Ch Excess (1 Excess temp. (1 The comparison sensor in the temperature sink has exceeded the limit temperature set in P881. The comparison sensor in the temperature sink has exceeded WES-max or WASolmax. (1 The reactions of the heating and DHW load circuits to the statuses Excess temp. and Excess can be defined separately in P431/471 SOL Yield HC or P611 SOL Yield DHW of the relevant WCM-FS / La 53-78
54 6.6.3 DTR Temperatures Display of the collector temperature (T1) and the bottom thermal store temperature (reference temperature, T2). Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Info Solar. Press function key DTR temperatures. Parameter DTR temperatures is displayed. Solar 02 DT controller Energy management Info Solar Info Solar 01 Buffer/De-couple Status DTR DTR temperatures - + DTR temperatures 903 T C T C / La 54-78
55 6.6.4 WHP Temperatures Display of the collector flow temperature (T3) and the collector return temperature (T4). Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Info Solar. Use dial knob to move to the second menu level. Press function key WHP temperatures. Parameter WHP temperatures is displayed. Solar 02 DT controller Energy management Info Solar Info Solar 02 WHP temperatures Collector circuit Yield counter - + WHP temperatures 904 T C T C / La 55-78
56 6.6.5 Collector circuit Display of the pump speed, the volume flow and the collector capacity. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Info Solar. Use dial knob to move to the second menu level. Press function key Collector circuit. Parameter Collector circuit is displayed. Solar 02 DT controller Energy management Info Solar Info Solar 02 WHP temperatures Collector circuit Yield counter - + Collector circuit 905 P Pump 00% V 0.00l/min P th 0.0kW / La 56-78
57 6.6.6 Solar yield counter Solar yield counter reading since last reset and date the counter was reset. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Info Solar. Use dial knob to move to the second menu level. Press function key Yield counter. Parameter Yield counter is displayed. Solar 02 DT controller Energy management Info Solar Info Solar 02 WHP temperatures Collector circuit Yield counter - + Yield counter 906 since 04.Aug 11 W th Oper 45.0kWh 124.0h Reset / La 57-78
58 6.6.7 Total solar yield Solar yield counter reading since commissioning. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Info Solar. Use dial knob to move to the third menu level. Press function key Total yield. Parameter Total yield is displayed. Solar 02 DT controller Energy management Info Solar Info Solar 03 Total yield Statistic - + Total yield 907 W th 561 kwh Oper 85 h / La 58-78
59 6.6.8 Statistic Display of solar yields and operating times of the last 14 days. Activate heating engineer level. Press function key Solar. Menu Solar is displayed. Use dial knob to move to the second menu level. Press function key Info Solar. Use dial knob to move to the third menu level. Press function key Statistic. Parameter Statistic is displayed. Solar 02 DT controller Energy management Info Solar Info Solar 03 Total yield Statistic - + Statistic : 20.Aug. 11 W th 200 kwh Oper 05 h The respective next day can be reached by scrolling / La 59-78
60 6.7 Reset WCM-SOL Reset is used to return the WCM-SOL to the factory settings. Set address switch on the WCM-SOL to A. All LED's are flashing. After approx. 10 sec. all standard values are loaded and the LED s go on in sequence (see Ch. 6.3). Set address on WCM-SOL. WCM-SOL determines all sensors and actuators connected. 6.8 Reconfiguring WCM-SOL for system alterations Disconnect power supply to WCM-SOL. Carry out installation modification. Reconnect power supply to WCM-SOL. It is possible that the WCM-FS assigned signals an error. Re-identify configuration of WCM-SOL / La 60-78
61 6.9 Manual function WCM-SOL Manual function is carried out via the address switch in the installation area. Manual operation solar Off Set address switch on WCM-SOL to 0. VA1- output Off M1- output Off PWM- output System (WST) LED display Off (0% capacity) Continues to operate on the consumer and exchanger side Mains LED flashes Manual operation solar venting Set address switch on WCM-SOL to E. VA1- output On M1- output On (1 PWM- output On (100% capacity) (1 System (WST) LED display Consumer and exchanger side functions are not affected Mains LED flashes (1 During stagnation the output is set to Off Emergency operation WCM-SOL Emergency operation temporarily bridges a fault condition. The WCM-SOL must not be operated in emergency mode for a prolonged period of time. With address setting F the output relay for the solar pump is switched on. Sett address switch on WCM-SOL to F (see Ch. 6.9). Mains LED flashes in impulse/pause ratio 50 % On and 50 % Off (see Ch. 6.3). Emergency operation Sett address switch on WCM-SOL to F. VA1- output Off M1- output On (1 PWM- output On (100% capacity) (1 System (WST) LED display Consumer and exchanger side functions are not affected Mains LED flashes (1 During stagnation the output is set to Off / La 61-78
62 6.11 Reset WCM-FS When resetting the remote control station, all previous setting will be reset to factory settings. Remove remote control station from its holder. Press and hold menu key whilst refitting it to the bracket. Press and hold the menu key, until "EEPROM" appears. Software version and EEPROM appear briefly. -weishaupt- WCM-FS EEPROM Select language (see Ch ). Set address (see Ch ). Remote control station is being reconfigured. -weishaupt- WCM-FS Mon 21.May 07 19:20 System start please wait Carry out commissioning (see Ch. 7) / La 62-78
63 7 Commissioning 7 Commissioning You will automatically be guided through the commissioning menu during initial commissioning, after reset. 7.1 Prerequisite CAUTION Possible damage to the equipment! Incorrectly carried out assembly, installation and commissioning can lead to failure of individual devices or the entire heating system. Only correctly carried out commissioning ensures the operational safety of the entire system. The commissioning may only be carried out by qualified personnel. Please check that all installation work has ben completed prior to commissioning Set address on WCM-SOL Check, and if necessary, set ebus address on WCM-SOL solar controller. 0 Manual operation 1 (Ch. 6.9) 1 Normal operation 2-9 Function not defined A Reset (see Ch. 6.9) B-D Function not defined E Manual operation 2 (Ch. 6.9) F Emergency operation (temporarily bridges a fault condition) The WCM-SOL solar controller controls the ebus supply automatically, not other measures are required / La 63-78
64 7 Commissioning 7.2 Commissioning procedures on the WCM-FS remote control station During commissioning you will automatically be guided through the setting menus required Setting the language When initially applying voltage when switching on the unit and after every reset, parameter Language is displayed. Set language using the dial knob. Save with function key OK. - + Language 311 English OK Selectable languages Deutsch English Français Italiano Espanol Nederlands Dansk Svenska Norsk Slovenski Hrvatski Magyar Polski Рyсский Cesky Slovak / La 64-78
65 7 Commissioning Set address assignment of the WCM-FS control station The solar controller is operated via the FS which, according to the address setting, has the functions DHW program, time master and circulation program. The following addresses are possible: Control centre#l, WTC-HC#1, WTC-HC#1 + EM-HC#2 and EM-HC#2. The address can only be set: during initial commissioning, after every reset. Display Functional assignment Control centre #L WTC-HC#1 WTC-HC#1+ EM-HC#2 EM-HC#2 Set address using the dial knob. Save with function key OK. Remote control station is being configured.. Control centre function (or WCM-Sol standalone without consumer connected). Operation WCM-Sol and direct pump heating circuit at WTC. Operation WCM-Sol and direct pump heating circuit at WTC and the heating circuit EM-HC#2. Operation WCM-Sol and WCM-EM-HC# Address FS 312 WTC-HC#1 OK Configuration The Software version is displayed briefly, then the remote control station is reconfigured. -weishaupt- WCM-FS Mon 21.May 07 19:20 System start please wait / La 65-78
66 7 Commissioning Sol procedure Adjustment of hydraulic variation. Activate heating engineer level (see Ch. 6.5). Press function key Commissioning. Menu Commissioning is displayed. Use dial knob to move to the second menu level. Press function key Sol procedure. Parameter Sol procedure is displayed. Make selection using the dial knob and save with function key OK. - + Sol procedure 317 WES-C Standard OK Display WASol WES-C Functional assignment Solar supported DHW preparation (see Ch ) with Weishaupt WASol water heater Solar supported DHW preparation as well as heating support (see Ch ) with Weishaupt WES thermal store / La 66-78
67 7 Commissioning Application B3 This parameter is used to define whether the WCM-Sol uses the store sensor of the WTC or of the EM-DHW#8. This means that a system without WTC can control a DHW consumer and the advantages of an EM-DHW, e.g. circulation sensor, can be utilised. Settings CPU/KA; EWW8 Activate heating engineer level (see Ch. 6.5). Press function key Commissioning. Menu Commissioning is displayed. Use dial knob to move to the third menu level. Press function key Application B3. Parameter Application B3 is displayed. Make selection using the dial knob and save with function key OK. - + Application B3 318 CPU/KA Standard OK / La 67-78
68 7 Commissioning Set number of collectors Settings Activate heating engineer level (see Ch. 6.5). Press function key Commissioning. Menu Commissioning is displayed. Use dial knob to move to the third menu level. Press function key Collector Number. Parameter Collector Number is displayed. Set number of collectors required using the dial knob and save with function key OK. - + Collector Number Standard OK / La 68-78
69 7 Commissioning Set type of WHPSol Selection of the pump assembly. Settings 20-7 EA 1.0 / EA 1.0 Activate heating engineer level (see Ch. 6.5). Press function key Commissioning. Menu Commissioning is displayed. Use dial knob to move to the third menu level. Press function key Type WHPSol. Parameter Type WHPSol is displayed. Select value required using the dial knob and save with function key OK. - + Type WHPSol EA 1.0 Standard OK / La 69-78
70 7 Commissioning OP Max This parameter is used to determine the volumetric flow at maximum pump speed. This is used to verify that the required volumetric flow of the collector panel can be achieved. The display shows: maximum pump speed volumetric flow/hour x number of collectors volumetric flow/min Activate heating engineer level (see Ch. 6.5). Press function key Commissioning. Menu Commissioning is displayed. Use dial knob to move to the third menu level. Press function key OP Max. Parameter OP Max is displayed. Start the system design check using function key On. Achieving the volumetric flow required for the number of collectors. Confirm the system design check with function key OK and save the value. OP Max PWM 95 % V 23.3l/h*n V 3.89l/min On OK The value entered represents the throughput at maximum pump capacity. The volumetric flow can be limited to the nominal volumetric flow of the system in P842 Max.V.Flow. The procedure can be found in (see Ch ). Limiting the maximum volumetric flow via P 842 Max.V.Flow allows savings in electrical energy / La 70-78
71 7 Commissioning OP Min The controller determines the minimum possible volumetric flow in the collector circuit. The parameter is used to check the stability of the minimum operating point (OP Min). Activate heating engineer level (see Ch. 6.5). Press function key Commissioning. Menu Commissioning is displayed. Use dial knob to move to the fourth menu level. Press function key OP Min. Parameter OP Min is displayed. Start check of lower operating point using function key On. Confirm check of lower operating point using function key OK. OP Min V min 0.60l/min PWM 24 % V 1.02l/min On OK During this process, the control LED on the volumetric flow sensor should be observed. This indicates the rotational direction of the FlowRotor as a result of the flow throughput. The constant interval of LED lighting should be checked. If the measured value is unstable or the sensor does not function correctly,raise minimum volumetric flow (P841 Min.V.Flow). Possible causes of faults could be contaminated or spent Tyfocor, air pockets in the collector circuit, opening pressure of the non return valve is not achieved / La 71-78
72 8 Information to optimise the operation of the system 8 Information to optimise the operation of the system Restricting the maximum volumetric flow saves electrical energy during the high yield phase! To do this, limit the max. volumetric flow to the nominal volumetric flow required for energy transportation (see Ch ). Excess temperatures at the hot water coil of the thermal store can lead to lime scale buildup. To avoid excess temperatures in the thermal store during solar energy yield, the energy can be discharged from the thermal store to the heating circuits (see Ch Sol Excess). Reheating of the heat exchanger during the solar yield phase reduces the energy gain of the system. Therefore, the reheat process of the WTC can be prevented depending on the solar yield. See examples (Ch Solar Prio HC) and (Ch Solar Prio DHW) / La 72-78
73 8 Information to optimise the operation of the system 8.1 A Parameters In rare cases it may be necessary to adjust the solar control to match the requirements of the system using the A parameters. A parameters can only be altered using the WCM Diagnostic Software. Parameters Description Factory setting A21 Minimum de-couple temperature 8 C A22 Maximum de-couple temperature 78 C A23 De-couple excess 1K A24 Modulation B10 Off A25 Boiler turndown temperature 0 A41 Stagnation switch off threshold: 120 C Maximum collector temperature A42 Switch off threshold: 110 C Maximum FlowRotor temperature A43 Maximum WASol temperature 90 C A44 Maximum WES-C temperature 90 C A49 min pump capacity WHPSol 15% A50 max pump capacity WHPSol 95% A61 V-P control parameter 10 A62 V-I control parameter 120 1/s A63 DTR-P control parameter 10 A64 DTR-I control parameter 120 1/s / La 73-78
74 9 Troubleshooting 9 Troubleshooting 9.1 Error codes Error messages from all ebus participants are displayed. A description of the individual errors can be found in the relevant installation and operating instructions. The WCM-FS only displays errors, which last 15 minutes or more. Errors and rectified errors are stored in the error history with error source, error code, date and time. Rectified errors are displayed with error code 00. A maximum 10 entries can be saved. Solar errors Error code Cause Error source Rectification 125 Control differential not achieved WCM-SOL The error messages will automatically reset when the control difference between T3 and T2 is reached. If the error re-occurs, reduce the setting in P841 (min volumetric flow) and P863 (control difference). 126 Despite pump activation no volumetric flow is measured. Pump/ Flow- Rotor Check pump operation and volumetric flow sensor (see Info in Ch ). Sensor faults Error code Cause Error source Rectification 130 Sensor B10 defective WCM-SOL Check sensor and replace if necessary 131 Sensor B11 defective WCM-SOL Check sensor and replace if necessary 132 Sensor T1 defective WCM-SOL Check sensor and replace if necessary 133 Sensor T2 defective WCM-SOL Check sensor and replace if necessary 134 Sensor T3 defective WCM-SOL Check sensor and replace if necessary 135 Sensor T4 defective WCM-SOL Check sensor and replace if necessary Hardware fault Error code Cause Error source Rectification 154 Error EEPROM Reset unit (see Ch. 6.7) ebus communication error Error code Cause Error source Rectification Communication error to WCM-FS Check ebus connection Check BUS level with ebus tester System error Rectify system error. Switch system off and on. System is being reconfigured. Error code Cause Error source Rectification 200 Bus identification occupied, 2 identical WCM-EM and WCM-FS 202 WCM-FS address WTC-HC#2+EM- HC#2 has been assigned to a DHW load circuit WCM-FS WCM-EM WCM-FS WCM-EM Check address setting Check address setting Check sensor on WCM-EM 203 SOL Buffer on WE WTC-XX Connect buffer sensor to WCM-SOL / La 74-78
75 10 Protection functions 10 Protection functions 10.1 Pump idle protection After a maximum idle time of 24 hours the pump on outputs M1 and VA1 (Bypass) is driven at maximum capacity for a duration of 5 seconds at 12:00 hrs Frost protection collector circuit The solar pump is operated at maximum capacity when the temperature at collector sensor T1 drops below the frost protection limit value P843 Collector Frost set Frost protection Store/Buffer The sensors B10, B11 and T2 are monitored for the frost protection temperature of 4 C. If this temperature is not maintained, the following controllable heat exchangers are request: WTC via temperature and/or load control external heat exchanger via VA output 10.4 System frost protection With SF at WTC: Via the frost protection system, the pumps of the heating circuits (EM-HC) are activated by the WTC#A at an external temperature B1 < P23 System frost protection. The WCM-SOL does not affect this mechanism. With SF at WCM-EM-HC: If the system sensor is connected to the WCM-EM-HC#2, the pumps of the heating circuits (EM-HC) are activated at an external temperature B1 < P466 System frost protection WCM-EM-HC 10.5 Collector circuit overheat protection The overheat protection of the collector circuit is divided into two parts: 1. Solar pump at maximum capacity, if T1 > A41 Collector Max Temp - 10K 2. Solar pump off, if T1 > A41 Collector Max Temp 10.6 Thermal store overheat protection (procedure 1) This function protects the thermal store from overheating. If the temperature at store sensor T2 exceeds the limit temperature set in A43 WASol Max, the solar pump is switched off / La 75-78
76 10 Protection functions 10.7 Thermal store overheat protection (procedure 2) This function protects the buffer from overheating. If the temperature at DHW sensor B3 exceeds the limit temperature set in A44 WES-C Max, the solar pump is switched off / La 76-78
77 11 Technical documentation 11 Technical documentation 11.1 Sensor variables Return sensor Flow sensor Comparison sensor Ext. room sensor Immersion sensor Collector sensor NTC 5KΩ STF 222 NTC 5KΩ STF 225 C Ω C Ω C Ω / La 77-78
78 12 Key word index A Address...65 Ambient conditions...14 Approval data...14 C Cable cross section...17 Commissioning...63 Configuration...29 Consumption...14 Control centre...65 D Dial knob...20 E EBUS connection...19 EBUS terminal...17 Electrical data...14 Emergency operation... 61, 63 user level...20 Error code...74 F Factory presetting... 21, 23, 27 Function key...20 Fusing...14 G Guarantee... 7 H Heating engineer level... 20, 25 Heating program...20 Housing cover...17 I Illumination...20 Input...19 Installation modification...60 O Operating display WCM-EM...22 Operating panel... 20, 36 P Parameter...27 Presence and absence key...20 R Reset...22, 60, 62, 63 Room sensor... 15, 17 S Safety measures... 8 Sensor... 19, 77 Sensor characteristics...77 Set factory presetting...26 Standard display...21 Standby...21 Storage...14 Sun...21 Supply voltage...14 Symbol type of operation...21 T Temperature...14 Transport...14 Type key... 9 Type of operation...21 U Umbrella...21 V Voltage supply...14 W Wall bracket...15 Water tap...21 L Language...64 Liability... 7 M Menu key...20 Menu structure...23 Moon...21 N Night setback operation...21 Normal operation / La 78-78
79 / La
80 Max Weishaupt GmbH, D Schwendi Weishaupt (UK) Limited Neachells Lane, Willenhall, WV13 3RG Printed in Germany. All rights reserved. Product Description Performance W-Burners Monarch and industrial burners The compact series, proven millions of times over: Economical, reliable, fully automatic. Gas, oil and dual fuel burners for domestic and commercial applications. The purflam burner gives almost soot-free combustion of oil with greatly reduced NO x emissions. The legendary industrial burner: Tried and tested, long lived, clear construction. Gas, oil and dual fuel burners for district heat provision. Up to 570 kw Up to 11,700 kw multiflam burners Innovative Weishaupt technology for large burners: Minimal emission values particularly at ratings over one megawatt. Oil, gas and dual fuel burners with patented fuel distribution system. Up to 17,000 kw WK industrial burners Modular powerhouses: Adaptable, robust, powerful. Oil, gas and dual fuel burners for industrial plant. Up to 22,000 kw Thermo Unit The Thermo Unit heating systems from cast iron or steel: Modern, economic, reliable. For environmentally friendly heating. Fuel: Gas or oil as desired. Up to 55 kw Thermo Condens Heat pumps Solar systems The innovative condensing boilers with the SCOT system: Efficient, low in emissions, versatile. Ideal for domestic heating. Floor standing gas condensing boiler with ratings of up to 1200 kw (cascade), for higher heat demands. The heat pump programme offers solutions for utilisation of heat from air, soil and ground water. The systems are suitable for refurbishment or new builds. It is possible to use several heat pumps in cascade operation. Free energy from the sun: Perfectly coordinated components, innovative, proven. Pleasantly shaped flat roof collectors to support heating and of domestic water Up to 1,200 kw Up to 130 kw Water heater / energy reservoir The attractive domestic water heating range includes classic water heaters which are supplied through a heating system and energy reservoirs which can be fed through solar systems. Control technology / building management From control panels to complete building management systems at Weishaupt you can find the entire spectrum of modern control technology. Future oriented, economical and flexible / La
1 General information
1 General information 1.1 About this manual This manual describes the installation, function and operation of an integrated solar control system, which is suitable for split pressurized solar heating system.
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
RVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
Smile. The All-In-One Heating Controller
Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from
Heating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Technical Information
Technical Information Interface with DDC 6 720 642 841-00.1RS Logamatic LON-Gateway For heating contractors during project planning 6 720 643 554 (11/2010) US/CA Contents Contents 1 Explanation of symbols
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1
--- OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM Serial number: Year: Please quote this number when contacting customer service!
MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS
MAKING MODERN LIVING POSSIBLE UniLynx Indoor User Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 2. Function Description 3 Definition
Instruction Manual for Operating Panel 301 and 302
Instruction Manual for Operating Panel 301 and 30 Edition: 1/006 Edition: 1/006 Contents 1 Introduction and Overview........................ 5 1.1 Panel 301 Controls........................................
A Class Air Source Heat Pump User Guide
A Class Air Source Heat Pump User Guide IMPORTANT THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLATION 8/60476/0 Issue 1.03 Contents 1: Introduction 1 2: How the Heat Pump Works 1 2.1 Tips and advice
RVR Hybrid System Installer Instructions - 10052012. RVR Hybrid System Controller Installation Instructions
RVR Hybrid System Controller Installation Instructions 1 Introduction to Hybrid Systems The RVR Hybrid system uses a combination of the Immergas Audax range of heat pumps with gas or oil boilers to create
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
RRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
Operating Instructions
Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage
Contents. Introduction
TION Contents Introduction...1 Basics...2 Main Menu Structure...3 Time Schedule Menu...4 Settings Menu...5 Reports Menu...6 Date / Time Adjustment Menu...7 Introduction TION is an advanced control device
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET
CM702 PROGRAMMABLE THERMOSTAT FEATURES Attractive slim, modern styling makes it ideal for location in any type of home. 24-hour heating program. Up to 4 daily independent time and temperature level changes
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
Inwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Air-conditioning controller. User's Manual NRT 107 F031, F041 7000986003 R2. 7000986003 R2 Sauter Components
R Air-conditioning controller User's Manual NRT 107 F031, F041 7000986003 R2 - 3 - Table of contents 1 General information... 5 1.1 Introduction... 5 1.2 Safety instructions... 5 1.3 Key to the operating
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
Thermostat with display
H/LN4691-0 674 59-64170 Thermostat with display RA00118AA_I-01PC-13W39 www.homesystems-legrandgroup.com Thermostat with display Contents Thermostat with display 1 Introduction 4 1.1 Warnings and recommendations
Nest Learning Thermostat Installation Guide. Installation step-by-step
Nest Learning Thermostat Installation Guide Installation step-by-step Contents Compatibility. 3 In the box. 4 Before you start. 5 Choose an installation method. 6 Replacing an existing wired thermostat.
DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.
1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions
Mounting and operating instructions CONTOIL DFM 8EDM Table of contents Safety instructions 2 - Designed use - Installation, commissioning and operation - Operational safety - Return of the instruments
CO2 Alarm. Operation. Application
CO Alarm 100-77V AC Supply Voltage Two pre-configured alarm and control thresholds Thresholds factory set to customer requirements on dispersive infrared sensing technology Optional internal audible alarm
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
T-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB
SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production SATK20 - SATK30 series ACCREDITED CALEFFI 01209/13 GB ISO 9001 FM 21654 ISO 9001 No. 0003 The latest generation heat
evohome Wireless Radiator Zoning Kit Installation & User Guide
evohome Wireless Radiator Zoning Kit Installation & User Guide Getting the most from your evohome system Installation & User Guide 1 Getting the most from your evohome system Thanks for choosing an evohome
Operating instructions
Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document
Tina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
VIESMANN. Installation and service instructions VITOTROL 100. for contractors
Installation and service instructions for contractors VIESMANN Vitotrol 100 Type UTDB-RF2 Room temperature controller with digital time switch and wireless receiver For applicability, see the last page
Overheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET
CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES CM927 can be installed without disrupting your room décor as no wiring connection is required between the room unit and the boiler Attractive, slim, ultra-modern
Technical Information
Date of last update: Oct-11 Ref: D7.8.4/1011/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors... 1
Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.
EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...
HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function
Specifications Supply Voltage 240VAC @ 0.07Amps or 24VAC @ 0.380Amps Relays 240V @ 12A max (resistive) / Comp1,2,3, Aux Ht, Rv O/B) Fuses (Equipment) 15 Amps Maximum 3AG Control Range Minus 10 to 50C Control
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
OZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Installation and Service Instructions for use by heating contractor SM1 SOLAR CONTROL MODULE IMPORTANT
Installation and Service Instructions for use by heating contractor Solar Control Module for solar connections to the Vitotronic control SM1 SOLAR CONTROL MODULE Product may not be exactly as shown IMPORTANT
Time switch D21-1-channel 4 126 31 / 32 / 33-047 61 / 63 / 6047 60. General information. Overview. Set language
Time switch D21-1-channel 4 126 31 / 32 / 33-047 61 / 63 / 6047 60! Safety notes GB This product should be installed in line with installation rules, preferably by a qualified electrician. Incorrect installation
Instruction manual for models:
Instruction manual for models: Prisma+ Prisma+ ivista Cast Aluminium Electric Radiators High Performance with Intelligent Technology INCORPORATiNG HiGH-PRECiSiON ELECTRONiC CONTROL WiTH THE LATEST ENERGY
Digital timer thermosatat. isense. Installation and Service Manual 120666-AG
EN Digital timer thermosatat isense Installation and Service Manual 120666-AG Contents 1 Preface...4 1.1 General...4 2 Location of the installation...5 2.1 Position of the regulator...5 2.2 Installation
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.
Data logger Installation and operating instructions SOREL Connect Read carefully before installation, commissioning and operation 1.1. - Specifications Description of data logger Electrical specifications:
Wireless 7 Day Programmable Room Thermostat
Wireless 7 Day Programmable Room Thermostat Cat. No. TRT037 Transmitter Receiver Operating & Installation Instructions What is a programmable room thermostat? an explanation for householders A programmable
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
SMM. Installation Operation Maintenance
SMM Configuration SMM Module for Scroll Units, H Generation Installation Operation Maintenance 1 0 L80 IM 022 GB SMM Configuration SMM Module for Scroll Units, H generation Foreword These installation,
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?
WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?...an explanation for householders A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set On and Off time periods
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Regulators. Heat pumps. Qualified technician NIBE TM AP-CS2.0. Operating Instructions UK
Operating Instructions UK Heat pumps Regulators Qualified technician NIBE TM AP-CS2.0 We reserve the right to make technical changes. 83052306bUK Translation of the operating manual Please read first This
Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3
EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
LK Electric Boiler - 4,5
LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered
Adjustable room thermostat for heating only or cooling only systems
3 003 Room hermostat RAA30 Adjustable room thermostat for heating only or cooling only systems Room thermostat with manual O/OFF switch wo-position control witching voltage AC 24 250 V Use he RAA30 room
Instruction manual. Electrobloc EBL 100-2
Instruction manual 0 Manual Electrobloc EBL 100-2 Electrobloc EBL 100-2 Type no. 911.503 Table of contents 1 Introduction..........................................2 2 Safety information.....................................2
Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
Instruction book IQAN-MDM. Publ. no. HY17-8328/UK Edition June, 2007
Instruction book IQAN-MDM Publ. no. HY17-8328/UK Edition June, 2007 Contents 1 Introduction...............................................................3 Safety symbols................................................................
Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480
Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Controls for fan coil units and cassettes
Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
User Manual. Gas fired condensing wall hung boiler. G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw)
User Manual Gas fired condensing wall hung boiler G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw) CLAS HE R 12 CLAS HE R 18 CLAS HE R 24 Country of destination GB, IE
For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers
For the owner Instructions for use ecotec Wall hung room sealed fan assisted condensing boilers GB Contents Specified use Notes on these instructions Specified use... Notes on these instructions.... Storage
User manual. Solid (FR 98,),
User manual Solid (FR 98,), If these instructions are not followed during installation and service, Thermia Värme ABliability according to the applicable warranty is not binding. Thermia Värme AB retains
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
Memcom Emergency Telephone
Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming
Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.
English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation... 3 3.2 The user interface