Schneider Electric Conext XW

Size: px
Start display at page:

Download "Schneider Electric Conext XW"

Transcription

1 Schneider Electric

2 Conext TM XW System One Solution for Global Power is an adaptable pure sine wave, single-phase and three-phase inverter/charger system with global grid-tie functionality and dual AC power inputs. Available solar charge controllers, monitoring, and automated generator control modules enable further adaptability. From single units to multiple clusters of units, up to 36kW each, the is a scalable system that allows for the integration of solar capacity as required. Adaptable and scalable, the Schneider Electric system is the One Solution for global grid-interactive and off-grid, residential and commercial, solar and backup power applications. Why Select? Easy to Install Devices Configure Quickly into a Stylish Wall Mounted System Inverters Connect Both Grid and Power with Dual AC Input Flexible Adapts to Single and Three-phase Systems Scales for Residential or Large Power Installations Supports DC Coupled and AC Coupled Solutions Easy to Service Remote Monitoring and Configuration Replaceable Boards and Components Global Support Higher Return on Investment Products Shown: Schneider Electric inverter/charger, XW PDP, XW CB, and MPPT solar charge controller Sell Power to the Utility with Global Grid Sell Function Harness the Continuously Declining Production Cost of Solar Power Hybrid Integration of Reduces Diesel Fuel Costs

3 Applications for the > Commercial Backup Power > Residential Backup Power > Commercial Grid-interactive Solar with Backup > Residential Grid-interactive Solar with Backup > Residential Off-grid Solar > Commercial Off-grid Solar with Backup > Community Electrification The Future The grid interactive feature-set is a key enabler for residential self consumption systems and utility demand response systems. supports both AC Coupled and DC Coupled self-consumption models. Communications functionality allows utility operators remote access to. is compatible with Lithium Ion battery packs.

4 > Commercial Backup Power Grid Commercial Load integrates with commercial building switchgear to seamlessly and instantly convert power from battery reserves to maintain operation of critical loads such as security, data and communication systems, as well as pumps and machinery when the power grid fails or browns out. When utility power is readily available, the will keep the battery bank fully charged, ready for the next time. systems can be scaled up to 36kW and configured for single-phase, split-phase or three-phase power. The easily integrates with a generator for extended backup time. > Commercial Grid-interactive Solar with Backup PV Modules Solar Charge Controller Grid Commercial Load In addition to providing backup power for commercial operations, the easily integrates Photovoltaic (PV) power reducing business dependency on utility power by offsetting consumption and increasing the return on investment. can also manage load shifting to avoid expensive time-of-day electricity charges. Integrating PV power in regions with weak or intermittent grid power will allow businesses to operate for extended periods of time without grid power. systems can be scaled up to 36kW and configured for single-phase, split-phase or three-phase power. The easily integrates with a generator to further increase business operating time when the grid is down. The control and monitoring capabilities of the system provides businesses with management information to ensure dependability is maintained and systems operate as they should.

5 > Commercial Off-grid Solar PV Modules Solar Charge Controller Residential Load Wherever independent off-grid power is required for the operation of remote farms, monitoring stations, telecom towers or work camps, the is a cost effective replacement for a diesel generator. If PV production is insufficient or unavailable to meet demand, a generator can be integrated by the and managed by the Automatic Start (AGS) module to assist with loads and recharge batteries as required. For existing off-grid diesel generator power systems, integrating a will facilitate the decrease in both generator run time and corresponding fuel costs. The control and monitoring capabilities of the system provides power management information for operators and peace of mind that remote property is secure and power dependent systems are operating as they should.

6 > Residential Backup Power Grid Residential Load Homeowners embrace the because it allows for fully-automated, hassle-free, backup power. Unlike a plug-in backup power pack or portable generator, the inverter/charger is integrated into the electrical system and seamlessly converts power from battery reserves to support critical loads such as pumps, security systems, refrigerators and electronics in the event of a power outage or brown-out. When utility power is readily available, the XW will keep the battery bank fully charged and ready for the next grid failure. The easily integrates with a generator for extended backup power. > Residential Grid-interactive Solar with Backup PV Modules Solar Charge Controller Grid Residential Load In addition to providing residential backup power, the s ability to easily integrate PV power will help reduce household dependency on utility power by offsetting consumption. supports DC coupled and AC coupled grid-tie systems. s grid-interactive feature also provides a means to sell excess power back to the utility, qualifying homeowners for locally available feed-in tariff programs and green tax credits, further increasing the return on investment. The easily integrates with a generator for extended backup power.

7 > Residential Off-grid Solar PV Modules Solar Charge Controller Residential Load For off-grid home owners, inverter chargers provide AC power from batteries. systems Maximum Power Point Tracking (MPPT) solar charge controllers enable PV modules to directly charge batteries. The pure sine wave output and high surge capabilities of Conext XW inverter/chargers start and run pumps with ease, enabling key water and sewage systems, and assisting smaller generators in starting difficult loads. The can integrate a fuel based generator enabling cost effective hybrid off-grid power solutions. The control and monitoring capabilities of the system provides off-grid home owners with management information to ensure dependability is maintained and systems operate as they should.

8 > Rural / Community Electrification PV Modules Solar Charge Controller Community Loads is adaptable and scalable, powering off-grid communities around the world and helping them qualify for renewable energy funding programs to establish reliable, high-quality localized community power plants. By coupling to renewable PV energy generation through the DC system, delivers a more affordable AC power solution than traditional off-grid systems that rely on power supplied from diesel generators alone. community based off-grid systems scale up in 36 kw clusters and are expandable at any time. supplies a standard AC voltage grid, enabling communities to not only benefit from the low cost and wide variety of common AC appliances and tools, but also from the continuously declining cost of renewable PV power generation. will also integrate diesel generators into a hybrid off-grid system increasing the flexibility and reliability of the entire system while still reducing community dependence on the ever increasing cost of fuel generators. Remote system monitoring and management is available for the supervision of and supporting system components. The Schneider Electric system is the One Solution for grid-interactive and off-grid, residential and commercial, solar and backup power applications.

9 Accessories XW PDP ( ) The XW PDP Power Distribution Panel with conduit box is factory-wired and labeled to support North American code-compliant inverter installations. Additional wiring and breaker kits can be added to a single XW PDP to integrate up to three and four MPPT solar charge controllers. XW CB ( ) The XW CB Conduit Box attaches to the bottom of a single concealing all wiring creating a neat and square installation alongside both the XW PDP and MPPT Solar Charge Controllers. XW CK ( ) The XW CK Connection Kit is a wiring kit and single conduit box used to connect a second to the XW PDP. All wires are measured, pre-cut and labeled for quick and easy installation. SCP ( ) The XW SCP System Control Panel provides a single point of control to setup and monitor an entire system of inverter/chargers, MPPT Solar Charge Controllers, XW AGS modules. AGS ( ) The XW AGS Automatic Start module automatically controls activation of a generator to provide Conext XW with power to recharge depleted batteries or assist with heavy loads. The XW AGS adds intelligent power management and eliminates time spent monitoring batteries and inverter loads. Conext Combox Communication Device ( ) Operators of Conext solar systems can now remotely monitor yield performance using devices of their choice, such as personal computers, tablet devices, or building management systems. Conext CM is compatible with Xanbus protocol devices. MPPT Solar Charge Controller ( ) The MPPT Solar Charge Controller tracks the maximum power point of a photovoltaic (PV) array to deliver the maximum available DC current directly to the battery bank for charging. Deployable as stand-alone unit or in multiples, the MPPT also fully integrates with the inverter/charger as a system. MPPT Solar Charge Controller ( ) The MPPT Solar Charge Controller offers an industry-first set of features and top performance that allows for large PV array systems to be easily installed and DC Coupled to the battery bank at the lowest overall cost. Fast Sweep MPPT charging technology helps harvest the most energy available from the PV array, even in partial shade conditions. 80 A of battery charge current allows for the connection of PV arrays rated up to 600 V. Deployable as stand-alone unit or in multiples, the MPPT also fully integrates with the inverter/ charger as a system.

10 Series (230 V / 50 Hz) Device short name XW XW Electrical specifications Continuous power 4.0 kva 6.0 kva Surge rating 8.0 kva (20 sec) 12.0 kva (15 sec) Output current 17.4 A 26.1 A Peak output current 35 A 53 A Input current at rated power 178 A 131 A Type of signal True sine wave True sine wave Automatic transfer relay 56 A 56 A Typical transfer time 8 ms 8 ms DC input voltage (nominal) 25.2 V 50.4 V Input voltage limits 22 to 32 V 44 to 64 V Charging current 150 A 100 A Power factor corrected charging Auxiliary relay output 0 to 12 V, maximum 250 ma DC 0 to 12 V, maximum 250 ma DC Power consumption (search mode) < 7 W < 7 W AC input voltage (nominal) 230 V +/- 3% 230 V +/- 3% Input voltage limits (bypass/charge mode) 165 to 280 V (230 V nominal) 165 to 280 V (230 V nominal) Frequency 50 Hz +/- 0.1 Hz 50 Hz +/- 0.1 Hz AC input frequency range (bypass/charge mode) 40 to 68 Hz (50 Hz nominal) 40 to 68 Hz (50 Hz nominal) Total harmonic distortion (THD) < 5% at rated power < 5% at rated power AC connections AC1 (Grid), AC2 () AC1 (Grid), AC2 () AC input breaker 60 A single-pole 60 A single-pole Utility interactive Available Available Efficiency Peak 94.0% 95.4% General specifications IP degree of protection IP20 (sensitive electric components sealed inside enclosure) Product weight 52.5 kg (116.0 lb) 55.2 kg (121.7 lb) Shipping weight 74.0 kg (163.0 lb) 76.7 kg (169.0 lb) Product dimensions (H x W x D) 58 x 41 x 23 cm (23.0 x 16.0 x 9.0 in) 58 x 41 x 23 cm (23.0 x 16.0 x 9.0 in) Shipping dimensions (H x W x D) 71.1 x 57.2 x 39.4 cm 71.1 x 57.2 x 39.4 cm (28.0 x 22.5 x 15.5 in) (28.0 x 22.5 x 15.5 in) Device mounting Wall mount (backplate included) Wall mount (backplate included) Ambient air temperature for operation -25 C to 70 C (-13 F to 158 F) (power derated above 45 C (113 F)) System Network and Remote Monitoring Available Available Warranty Five-year standard Five-year standard Part number Features and options Display type Supported battery types bank size Status LEDs indicate AC In status, faults/warnings, equalize mode, On/Off and equalize button battery level. Three-character display indicates output power or charge current Flooded (default), Gel, AGM, custom Flooded (default), Gel, AGM, custom Flooded (default), Gel, AGM, custom 100 to 2000 Ah (scaled to PV array size) temperature sensor Included Included Non volatile memory Yes Yes Multiple unit configurations Single-phase: up to four parallel units. Three-phase: two units per phase Regulatory approval CE marked according to the following EU directives and standards: EMC Directive EN , EN , EN , EN Low Voltage Directive EN50178 RCM Marked and Compliant AS , AS , AS/NZS 3100 Specifications are subject to change without notice.

11 Series (120 / 240 V / 60 Hz) Device short name XW XW Electrical specifications Continuous power 4.0 kva 6.0 kva Surge rating 8.0 kva (20 sec) 12.0 kva (15 sec) Peak output current L-N: 70 A (20 sec), L-L: 35 A (20 sec) L-N: 105 A (15 sec), L-L: 52.5 A (15 sec) Input current at rated power 178 A 130 A Type of signal True sine wave True sine wave Automatic transfer relay 60 A 60 A Typical transfer time 8 ms 8 ms DC input voltage (nominal) 25.2 V 50.4 V Input voltage limits 22 to 32 V 44 to 64 V Charging current 150 A 100 A Power factor corrected charging Auxiliary relay output 0 to 12 V, maximum 250 ma DC 0 to 12 V, maximum 250 ma DC Idle consumption (search mode) < 8 W < 8 W AC input voltage (nominal) 120 / 240 V split-phase 120 / 240 V split-phase AC output voltage L-N: 120 V +/- 3%; L-L: 240 V +/- 3% L-N: 120 V +/- 3%; L-L: 240 V +/- 3% Input voltage limits (bypass/charge mode) AC1 voltage range (sell mode) L-N: 80 to 150 V (120 V nominal); L-L: 160 to 270 V (240 V nominal) L-N: 108 to 130 +/- 1.5 V; L-L: 214 to 260 +/- 3.0 V (automatically adjusts when entering sell mode) Frequency 60 +/-0.1 Hz 60 +/-0.1 Hz AC input frequency range (bypass/charge mode) AC1 frequency range (sell mode) 55 to 65 Hz (default); Hz (allowable) 59.4 to / Hz (automatically adjusts when entering sell mode) Total harmonic distortion (THD) < 5% < 5% AC connections AC1 (Grid), AC2 () AC1 (Grid), AC2 () AC input breaker 60 A two-pole 60 A two-pole Utility interactive Yes Yes CEC power rating 4.0 kw kw Efficiency Peak 94.0% 95.4% CEC weighted 91.0% 92.5% General specifications NEMA degree of protection NEMA1R (Indoor rating) (sensitive electronic components sealed inside enclosure) Product weight 52.5 kg (116.0 lb) 55.2 kg (121.7 lb) Shipping weight 74.0 kg (163.0 lb) 76.7 kg (169.0 lb) Product dimensions (H x W x D) 58 x 41 x 23 cm (23.0 x 16.0 x 9.0 in) 58 x 41 x 23 cm (23.0 x 16.0 x 9.0 in) Shipping dimensions (H x W x D) 71.1 x 56.5 x 26.7 cm (28.0 x 22.3 x 10.5 in) 71.1 x 56.5 x 26.7 cm (28.0 x 22.3 x 10.5 in) Ambient air temperature for operation -25 to 70 C (-13 to 158 F) (power derated above 45 C (113 F)) System Network and Remote Monitoring Available Available Warranty Five-year standard Five-year standard Part number Features and options Display type Status LEDs indicate AC In status, faults/warnings, equalize mode, battery level. Three-character display indicates output power or charge current, fault/warning codes. On/off and equalize buttons Supported battery types Flooded (default), Gel, AGM, custom Flooded (default), Gel, AGM, custom bank size 100 to 2000 Ah (scaled to PV array size) temperature sensor Included Included Multiple-unit configurations Split-phase: up to four parallel units in 120/240 V. Three-phase: up to two units per phase (six units total) Regulatory approvals Safety UL1741, CSA EMC FCC and Industry Canada Class B Interconnect IEEE 1547 and CSA Specifications are subject to change without notice.

12 Make the most of your energy Head office 35 rue Joseph Monier CS Rueil-Malmaison Tel.: +33 (0) France Schneider Electric As a global specialist in energy management with operations in more than 100 countries, Schneider Electric offers integrated solutions across multiple market segments, including leadership positions in energy and infrastructure, industrial processes, building automation, and data centres/networks, as well as a broad presence in residential applications. Focused on making energy safe, reliable, and efficient, the company's 100,000 plus employees achieved sales of 22 billion euros in 2011, through an active commitment to help individuals and organizations "Make the most of their energy". Copyright 2012 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. The mark IEEE Std TM is the registered trademark of the Institute of Electrical and Electronics Engineers, Inc. Follow us on BR _XW_01

Off-grid solar and backup power installations

Off-grid solar and backup power installations Off-grid solar and backup power installations A World of Power Problems... Residential Backup Power Grid-Interactive 3-Phase Commercial Buildings with Backup Power Grid-Interactive Residential with Backup

More information

Grid-tie, off-grid solar and backup power solutions. For residential and commercial installations

Grid-tie, off-grid solar and backup power solutions. For residential and commercial installations Grid-tie, off-grid solar and backup power solutions For residential and commercial installations Grid-tie and off-grid backup PV solutions Smarter investment in photovoltaic solutions for all grid-tie,

More information

AC Coupling of Inverters for Grid Tied PV Systems

AC Coupling of Inverters for Grid Tied PV Systems AC Coupling of Inverters for Grid Tied PV Systems AC Coupling with Conext s, Xantrex GT Inverters, and Conext TX Inverters Application Note 976-0240-01-01 Rev B DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION,

More information

Re-defining the utility-scale inverter

Re-defining the utility-scale inverter Re-defining the utility-scale inverter We believe in green energy in the ability to meet and contribute to growing power demands while supporting a smart grid that serves a smart society. Solution at a

More information

SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion

More information

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources

More information

Satcon Solstice 100 kw System Solution

Satcon Solstice 100 kw System Solution Clean power. SDMS-0100-208-LNU SDMS-0100-240-LNU SDMS-0100-480-LNU 5-12% mprovement in Total Energy Harvest 20-25% Reduction in Balance of System Expense The industry s first complete power-harvesting

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

HYBRID POWER SYSTEMS for TELECOM applications

HYBRID POWER SYSTEMS for TELECOM applications HYBRID POWER SYSTEMS HYBRID POWER SYSTEMS HYBRID POWER SYSTEM WITH AC GENSET PRAMAC has developed a new solution that allow coupling a traditional AC constant speed diesel genset with an energy storage

More information

Your own power station: For continuous power

Your own power station: For continuous power Mass Combi Ultra Your own power station: For continuous power Compact and lightweight inverter/battery charger Seamless switching between generator and grid Separate second charger Integrated MPPT solar

More information

ABB central inverters PVS800 100 to 1000 kw

ABB central inverters PVS800 100 to 1000 kw Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

46120-F0 Solar Energy Training System

46120-F0 Solar Energy Training System 46120-F0 Solar Energy Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 3 Table of Contents of

More information

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /

More information

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where the power generated by the solar panel (panels) runs an

More information

MidNite Solar E-Panels Explained

MidNite Solar E-Panels Explained MidNite Solar E-Panels Explained A MidNite Solar E-panel is an AC/DC Disconnect Box that has the Inverter installed on the door of the E-Panel or above the E-panel. MidNite's E-Panels place the AC and

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications

More information

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit

More information

SRS2025. Home & small Business. Energy Storage Solution

SRS2025. Home & small Business. Energy Storage Solution SRS2025 Home & small Business Energy Storage Solution Leclanché Lithium-ion complete system The ideal energy storage system for Home & Small Business Lithium-ion battery storage systems Home & Small Business

More information

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw

ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw Solar inverters ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw ABB s central inverters are extremely scalable, modular-inverter systems that are based on 55kW modular

More information

AC Coupling in Renewable Energy Systems

AC Coupling in Renewable Energy Systems AC Coupling in enewable Energy Systems Most renewable energy systems are DC coupled Most renewable energy systems are based on DC current, yet these have certain scalability limitations. Higher currents

More information

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS + Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,

More information

Fronius IG Plus. The next generation grid-connected PV inverter

Fronius IG Plus. The next generation grid-connected PV inverter Fronius IG Plus The next generation grid-connected PV inverter Maximum energy harvest cloudy or clear The first complete inverter solution. Reliable. Proven. Smart. An outstanding addition to the family:

More information

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges

More information

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial MODEL NUMBER: SMART1500SLT Highlights 1.5kVA / 1500VA line interactive tower UPS; Sine wave output

More information

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

Figure. 1 - Split Phase 240/120V circuit (180 phase shift) This technical note describes the option of connecting the 60Hz XW Inverter/Charger to a three-phase source by using a transformer to convert the AC source to split-phase 240/120V. INTRODUCTION: Split-phase

More information

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000 Photovoltaic Inverter Specification Version 2.06 1500 2000 3000 4000 5000 Kinglong New Energy Technology Co.Ltd. Kinglong New Energy Technology Co.Ltd. specification 1.1. Introduction... 3 1.1.1. Environment...

More information

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog APC DIN Rail Control Panel Mounting Uninterruptible Power Supply Catalog 2014 Contents Introduction, description... 4 Specifications...5 References....6 Dimensions...7 Wiring diagrams....8 Product reference

More information

Understand Hybrid Generator Battery Systems

Understand Hybrid Generator Battery Systems Understand Hybrid Generator Battery Systems For off-grid applications powered by diesel generators, move to cyclic operation to save costs Telecommunications operators in Africa, India and other developing

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

Microgrids and self-generation with renewable energies

Microgrids and self-generation with renewable energies Energías Renovables Microgrids and self-generation with renewable energies Technology for energy efficiency CIRCUTOR Renewables Modern energy needs have caused the firm introduction of renewable energies,

More information

Renewable Energy Catalog

Renewable Energy Catalog Smart choice for power Renewable Energy Catalog Inverters Inverter/Chargers System Components www.xantrex.com Renewable Energy Catalog About Xantrex Xantrex Technology Inc., which acquired Trace Engineering

More information

THE SOLAR TRANSFORMER. Portable Integrated Solar Power

THE SOLAR TRANSFORMER. Portable Integrated Solar Power THE SOLAR TRANSFORMER Portable Integrated Solar Power INTRODUCTION Spectral Utilities offers innovative micro-utility services for temporary, off-grid and smart-grid applications. We provide resources

More information

Batteries and inverters

Batteries and inverters Batteries and other energy storage devices store energy so that it can be used when needed. In a stand-alone power system, the energy stored in batteries can be used when energy demand exceeds the output

More information

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5 White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

SUNNY TRIPOWER 5000TL 12000TL

SUNNY TRIPOWER 5000TL 12000TL SUNNY TRIPOWER 5000TL 12000TL STP 5000TL-20 / STP 6000TL-20 / STP 7000TL-20 / STP 8000TL-20 / STP 9000TL-20 / STP 10000TL-20 / STP 12000TL-20 NEW available as 10 kva and 12 kva versions Economical Flexible

More information

The Intelligent, Reliable Cloud-Connected Inverter for Utility-Scale Renewable Power

The Intelligent, Reliable Cloud-Connected Inverter for Utility-Scale Renewable Power The Intelligent, Reliable Cloud-Connected Inverter for Utility-Scale Renewable Power Conext SmartGen Inverter TM solar.schneider-electric.com 2 solar.schneider-electric.com From Schneider Electric, your

More information

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMART500RT1U Description Tripp Lite's SMART500RT1U intelligent, line-interactive rack/tower uninterruptible

More information

INVERTER SYSTEM PRODUCT BROCHURE

INVERTER SYSTEM PRODUCT BROCHURE INVERTER SYSTEM PRODUCT BROCHURE DC AC the SolaX inverter The solar inverter is a critical technological component that is the heart of any PV plant. A solar inverter, or PV inverter, converts the variable

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U

More information

Seize the benefits of green energy and the smart grid

Seize the benefits of green energy and the smart grid Seize the benefits of green energy and the smart grid Electrical energy storage system for buildings optimizes self-consumption, costs, and reliability Are you getting the most from your onsite energy

More information

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management

More information

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,

More information

AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,

More information

Xantrex Solar Monitor Widget. User Guide

Xantrex Solar Monitor Widget. User Guide Xantrex Solar Monitor Widget User Guide Xantrex Solar Monitor Widget User Guide About Xantrex Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products

More information

Galaxy VM. Three-phase power protection. schneider-electric.com

Galaxy VM. Three-phase power protection. schneider-electric.com Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,

More information

SolarMax P series The power package for residential solar plants

SolarMax P series The power package for residential solar plants SolarMax P series The power package for residential solar plants The future-proof solution The requirements for residential photovoltaic plants have increased continuously in the past years. Due to our

More information

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1 User Manual Hybrid 1KW-5KW INVERTER / CHARGER Version: 1.1 Table of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Product Overview... 3 INSTALLATION...

More information

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1000RT2U Highlights 1kVA / 1000VA / 900W line-interactive 2U rack/tower UPS, Sine

More information

Mixing Sodium and Lead Battery Technologies in Telecom Applications

Mixing Sodium and Lead Battery Technologies in Telecom Applications Mixing Sodium and Lead Battery Technologies in Telecom Applications Paul Smith Shanon Kolasienski Technical Marketing Manager Application Engineer GE Critical Power GE Energy Storage Plano, TX 75074 Schenectady,

More information

PV And Storage: Solutions with Potential

PV And Storage: Solutions with Potential EN PV And Storage: Solutions with Potential Energy on demand with the Sunny Central Storage Large-scale storages... support the growth of renewable energies complete diesel and solar diesel hybrid systems

More information

Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert

More information

Additional Solar System Information and Resources

Additional Solar System Information and Resources Additional Solar System Information and Resources Background information a. Roughly 400 schools in NJ already have solar systems, producing more than 91 MW, out of approximately 2500 K- 12 schools in NJ.

More information

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,

More information

GSM ATT Modules Simply effective remote control

GSM ATT Modules Simply effective remote control GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential

More information

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine

More information

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line

More information

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power

More information

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions Self-Retracts 30 ft. Charge Cable Length Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions Safe, Convenient & Clean EV Charging The EVoReel cable management solutions

More information

Application Information Improving Efficiency in Smart Grid Applications With Fully Integrated Current Sensing ICs

Application Information Improving Efficiency in Smart Grid Applications With Fully Integrated Current Sensing ICs Application Information Improving Efficiency in Smart Grid Applications With Fully Integrated Current Sensing ICs By Shaun Milano, and Andreas P. Friedrich Allegro MicroSystems Europe Focus on the Photovoltaic

More information

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V

More information

JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL

JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL JSI Series Single Phase String Inverter Features JSI-500TL JSI-000TL JSI-500TL High performance string inverters ØFrom.5KW to 6.0KW ØWide PV input voltage range ØRapid MPPT tracking technology ØSuperior

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

Schneider Electric renewable energies catalog

Schneider Electric renewable energies catalog Schneider Electric renewable energies catalog > Solar inverters > Solar inverter/chargers > System components > Accessories > Solutions B Contents About Schneider Electric 3-4 Schneider Electric Professional

More information

Solutions for Photovoltaic Systems. Large buildings and power plants

Solutions for Photovoltaic Systems. Large buildings and power plants Solutions for Photovoltaic Systems Large buildings and power plants Helping you achieve the lowest cost of energy for your project When it comes to large-scale installations, you need a solar solution

More information

Technical Information POWER PLANT CONTROLLER

Technical Information POWER PLANT CONTROLLER Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for

More information

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79

More information

A SOLAR GUIDE - EVERYTHING YOU NEED TO KNOW

A SOLAR GUIDE - EVERYTHING YOU NEED TO KNOW WE BRING GREEN SOLUTIONS TO YOU A SOLAR GUIDE - EVERYTHING YOU NEED TO KNOW Provided by A COOLER PLANET A Cooler Planet 1 The Complete Solar Guide WHY GO SOLAR? TOP FIVE FACTORS TO CONSIDER FOR ADDING

More information

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with SOLAR MICRO INVERTER 260 COMMUNICATI GATEWAY Apparent Power Control (APC) P Q unique micro inverter with REAL & REACTIVE POWER CTROL 2 Micro Inverters unique micro inverter with real & reactive power control

More information

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port MODEL NUMBER: OMNIVS1500 Highlights 1500VA / 1.5kVA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75 to 147V

More information

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE Perfect Welding Solar Energy Perfect Charging FRONIUS ENERGY PACKAGE The personal storage solution for 24H Sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic

More information

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET FOR IMMEDIATE RELEASE No. 2387 Product & Catalogue Inquiries: Media Contact Naoto Shimada Travis Woodward Nakatsugawa Works Public Relations Department Photovoltaic Power System Business Center Mitsubishi

More information

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data KACO-monitoring watchdog insight prolog Integrated monitoring available Monitor up to 32 inverters per prolog Reliable and accurate data Email alarms to maximize uptime Historical, current and production

More information

Reduce energy costs with efficient solar power. Photovoltaic products and solutions for residential & commercial buildings, and power plants

Reduce energy costs with efficient solar power. Photovoltaic products and solutions for residential & commercial buildings, and power plants Reduce energy costs with efficient solar power Photovoltaic products and solutions for residential & commercial buildings, and power plants Innovative photovoltaic solutions that give you world-class,

More information

HOMER Software Training Guide for Renewable Energy Base Station Design. Areef Kassam Field Implementation Manager

HOMER Software Training Guide for Renewable Energy Base Station Design. Areef Kassam Field Implementation Manager HOMER Training Guide for Renewable Energy Base Station Design Areef Kassam Field Implementation Manager Solar Table of Contents Introduction Step Step Step Step Solar Step Step Step Step Solar Introduction

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

Battery Backup for Grid-Tied PV Systems

Battery Backup for Grid-Tied PV Systems A presentation for solar industry professionals Presented by Doug Pratt, and SimpleRay Solar SMA Sunny Island System Large(!)Outback System But first, a moment of thanks for northern California growers

More information

POWERWALL AND POWERPACK TESLA BATTERIES

POWERWALL AND POWERPACK TESLA BATTERIES POWERWALL AND POWERPACK TESLA BATTERIES M. Ragheb 5/12/2015 INTRODUCTION It is waiting that helps you as an investor, and a lot of people just cannot stand to wait. Charles Munger It is interesting to

More information

ALL STAR ELECTRIC COMPANY 10,000 Trumbull SE, Suite #F Albuquerque, NM 87123 (505) 856-1010 voice & fax NM License 21880 www.allstarelec.

ALL STAR ELECTRIC COMPANY 10,000 Trumbull SE, Suite #F Albuquerque, NM 87123 (505) 856-1010 voice & fax NM License 21880 www.allstarelec. ALL STAR ELECTRIC COMPANY 10,000 Trumbull SE, Suite #F Albuquerque, NM 87123 (505) 856-1010 voice & fax NM License 21880 www.allstarelec.com On-Site Power System Specialists: Photovoltaics, Wind Turbine

More information

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2014 Class 2800 CONTENTS Description............................................ Page 2 Outdoor

More information

SOLAR HOME SYSTEMS. This package is a basic Solar Home System designed for those who have small power demands.

SOLAR HOME SYSTEMS. This package is a basic Solar Home System designed for those who have small power demands. SOLAR HOME SYSTEMS This package is a basic Solar Home System designed for those who have small power demands. System voltage: 12V This Package comprises: 135W Solar Modules: 1 Suntech135W modules Solar

More information

Model #: SMART2200CRMXL

Model #: SMART2200CRMXL Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for

More information

Evolion Li-ion battery. Saft s proven ultra-compact solution for telecom applications

Evolion Li-ion battery. Saft s proven ultra-compact solution for telecom applications Evolion Li-ion battery Saft s proven ultra-compact solution for telecom applications Saft: Providing energy for today s telecom installations Saft has a complete range of specialised batteries for a wide

More information

Financial Analysis of Solar Photovoltaic Power plant in India

Financial Analysis of Solar Photovoltaic Power plant in India Financial Analysis of Solar Photovoltaic Power plant in India M. Ganga Prasanna, S. Mahammed Sameer, G. Hemavathi Department of Management Studies MadanapalleInstitute of Technology& Science Post Box No:

More information

Solar Inverter Product Overview. Solar inverters, monitoring and support for PV installations of all sizes. www.solar-inverter.com

Solar Inverter Product Overview. Solar inverters, monitoring and support for PV installations of all sizes. www.solar-inverter.com Solar Inverter Product Overview Solar inverters, monitoring and support for PV installations of all sizes www.solar-inverter.com SOLIVIA Monitor Monitoring for your PV installation SOLIVIA Monitor is a

More information

Accessories SUNNY REMOTE CONTROL

Accessories SUNNY REMOTE CONTROL Accessories SUNNY REMOTE CONTROL Mounting Instructions SRC20-MO-IEN121010 IMEN-SRC20 Version 1.0 EN SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This

More information

Hybrid and Off grid Systems Princeton Power Systems Inverter Technology Ken McCauley and Alan Cohen Princeton Power Systems

Hybrid and Off grid Systems Princeton Power Systems Inverter Technology Ken McCauley and Alan Cohen Princeton Power Systems Hybrid and Off grid Systems Princeton Power Systems Inverter Technology Ken McCauley and Alan Cohen Princeton Power Systems Core Technologies High quality, Robust Power Electronics: Grid Tied Inverter

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites Standards Certification Education & Training Publishing Conferences & Exhibits Michael

More information

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

A reasonable, new furnace (mid efficiency) has the following electrical requirements: June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious,

More information

Eaton UPS 9355 20-30kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

Eaton UPS 9355 20-30kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS. Eaton UPS 9355 20-30kVA Energía Rating 20 kva/18 kw and 30 kva/27 kw 0.9 power factor Topología True double-conversion online UPS Entrada eléctrica Nominal input voltage 208V/120V, 220V/127V+15, -20% 480V/277V,

More information

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise

More information

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001R02/13 2013 Class 2800 CONTENTS Description............................................ Page 2 Indoor Charging

More information

UPS system for emergency lighting and smoke extraction

UPS system for emergency lighting and smoke extraction UPS system for emergency lighting and smoke extraction Requirements There are a number of standards that apply to emergency lighting and smoke extraction systems (for example: NFS 61-940 [France only]

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.