CMG-3ESP Compact. Triaxial Broadband Seismometer. Operator's guide. Part No. MAN-C3E-0001
|
|
|
- Alexandra Hawkins
- 10 years ago
- Views:
Transcription
1 Triaxial Broadband Seismometer Operator's guide Part No. MAN-C3E-0001 Designed and manufactured by Güralp Systems Limited 3 Midas House, Calleva Park Aldermaston RG7 8EA England Proprietary Notice: The information in this manual is proprietary to Güralp Systems Limited and may not be copied or distributed outside the approved recipient's organisation without the approval of Güralp Systems Limited. Güralp Systems Limited shall not be liable for technical or editorial errors or omissions made herein, nor for incidental or consequential damages resulting from the furnishing, performance, or usage of this material
2 Table of Contents 1 Introduction Options Sensor response Installing the 3ESP Compact First encounters Installation notes Installing in vaults Installing in pits Rapid installation Installing in postholes Calibrating the 3ESP Compact The calibration pack Calibration methods Calibration with Scream! Calibration with a handheld control unit The coil constant Accessories The handheld control unit Inside the 3ESP Compact The sensors The control system The feedback system Connector pinouts Sensor and control unit pin output Appendix A.2 DC POWER connector Specifications Revision history
3 Operator's guide 1 Introduction The is a full-featured three-axis seismometer consisting of three sensors in an ultra-lightweight case, which can measure the north/south, east/west and vertical components of ground motion simultaneously. Each sensor is sensitive to ground vibrations in the frequency range Hz, a broadband frequency response made possible by advanced force-balance feedback electronics. Because of this wide response range, the 3ESP Compact can replace many of the instruments conventionally used in a seismic observatory; it also produces true pulse-shape records suitable for modern earthquake mechanism analysis. Its small size and low weight make it an ideal choice for rapid deployment of low-noise installations. The 3ESP Compact will produce the best results if it is mounted on a hard, near-horizontal surface well coupled to the bedrock. After levelling and orienting the case, you can perform accurate adjustments internally by sending the instrument control signals. These electronics allow it to compensate for a tilt of up to 3 from horizontal. The seismometer unit is self-contained apart from its 12 V power supply. Once levelled and centred, it will begin operating automatically. It outputs analogue voltages representing ground November
4 velocity on balanced differential lines. These voltages can be recorded using a separate logging device or digitizer. For testing and installation purposes, a handheld control unit is supplied which can monitor the instrument's output. Centring and mass locking can be carried out by sending control signals to the instrument, either through the handheld control unit or through an attached Güralp digitizer. Each seismometer is delivered with a detailed calibration sheet showing its serial number, measured frequency response in both the long period and the short period sections of the seismic spectrum, sensor DC calibration levels, and the transfer function in poles/zeros notation. 1.1 Options Digitizer modules The 3ESP Compact can be supplied with an integral digitizer, which is mounted on top of the mechanics to form a complete, lightweight digital seismometer suitable for autonomous installations. Output types The standard 3ESP Compact has a single 26-pin mil-spec waterproof connector for signals, control and power. As an option, the 3ESP Compact can be supplied with other output connector types, e.g. standard 26-pin D sockets, to your own pinout specification. 1.2 Sensor response The 3ESP Compact can be supplied with a response which is flat to 4
5 Operator's guide velocity from 100 Hz to any of 0.1 Hz (10 s), Hz (30 s), Hz (60 s), 0.01 Hz (100 s) or Hz (120 s). Alternatively, a hybrid response function may be provided. See Section 5.1, page 38, for more details. If you do not require high-frequency data, a low-pass filter may be installed at a frequency (below 100 Hz) that you specify. November
6 2 Installing the 3ESP Compact 2.1 First encounters Unpacking The 3ESP Compact seismometer is delivered in a single transportation case. The packaging is specifically designed for the 3ESP Compact and should be reused whenever you need to transport the sensor. Please note any damage to the packaging when you receive the equipment, and unpack on a safe, clean surface. The package should contain: the seismometer; a cable to join the sensor to the breakout box; the breakout box (which provides separate connections for the signal, control and power lines); a Handheld Control Unit (HCU) for monitoring sensor outputs and calibration, if ordered; a 10-pin connector for your power lead (see below); and a calibration and installation sheet. Assuming all the parts are present, stand the seismometer in the centre of a bench and identify its external features: 6 a handle with North indication, a multi-pole socket for input and output, other optional connectors as ordered; a bubble level, an air vent port, twothree adjustable feet, and two accurate orientation pins (one brass and one steel).
7 Operator's guide Serial number The sensor's serial number can be found on the label stuck to the top lid of the sensor. You should quote this serial number if you need assistance from Güralp Systems. Handling notes The 3ESP Compact is a sensitive instrument, and is easily damaged if mishandled. If you are at all unsure about the handling or installation of the device, you should contact Güralp Systems for assistance. Avoid bumping or jolting any part of the sensor when handling or unpacking. Do not kink or walk on the data cable (especially on rough surfaces such as gravel), nor allow it to bear the weight of the sensor. Do not connect the instrument to power sources except where instructed. Do not ground any of the signal lines from the sensor. Avoid moving the instrument whilst the masses are unlocked. The 3ESP Compact is designed to tolerate a certain amount of motion with the sensor masses unlocked, e.g. over short distances carried by hand. For example, if the remote locking procedure fails, removing the instrument for diagnostics is unlikely to damage it. However, you should always lock the sensor masses before shipping or transporting the sensor over longer distances. Connections The instrument has a single connector, which can be joined using the cable provided to a digitizer or breakout box. Individually shielded twisted-pair cabling must be used for the sensor outputs, control lines and power supply. If you need to make up a suitable cable, you should confirm the cable type with Güralp Systems. Using a digitizer The 3ESP Compact can be connected directly to any Güralp Systems digitizer using the signal cable provided. This is the simplest way to use a 3ESP Compact instrument. All the instrument's functions are available through the digitizer, including centring, locking and unlocking. November
8 We recommend that you keep the digitizer near the instrument if at all possible, to minimize the length of analogue cable required. Once digitized, the signal is robust to degradation by noise or attenuation. Keeping the digitizer in the quiet, stable conditions of a seismic installation also provides it with an optimum environment for the onboard ADCs. The breakout box This unit separates the lines in the signal cable, so you can connect a power supply, a recording system, and the handheld control unit: You can also use the breakout box to centre, lock and unlock the sensor masses. You will need to provide power through the breakout box's POWER connector to do this (see below.) 8 To unlock the sensor masses, hold down the ENABLE and UNLOCK buttons simultaneously for 7 seconds. The BUSY LED will light. All three masses are unlocked, each in turn. The sensor then automatically moves on to centre the masses, during which time the BUSY LED will flash. When the BUSY LED goes out, the instrument is ready for use. To lock the sensor masses, hold down the ENABLE and LOCK buttons simultaneously for 7 seconds. When the BUSY LED goes out, the instrument is ready for transportation.
9 Operator's guide To re-centre the sensor masses, hold down the ENABLE and CENTRE buttons simultaneously for 7 seconds. When the BUSY LED stops flashing, the centring process has finished. You may need to initiate several rounds of centring before the instrument is ready; when no more centring is required, pressing the ENABLE and CENTRE buttons has no effect. For more details on the control system, see Section 5.2, page 38. The standard breakout box is rain resistant but not waterproof. If you intend to use a breakout box in your installation, you should site it away from potential flooding. If this is not possible, a larger unit is optionally available which can be immersed in water. (The 3ESP Compact itself is, however, completely waterproof.) Power supply The sensor requires a 12 V power supply, which it obtains through the socket and breakout box or digitizer. You will need to make up a suitable cable to connect a 12 V power source to the 10-pin connector on the breakout box (spare 10-pin mil-spec connectors are provided for this purpose.) Using a 12 V, 25 Ah sealed heavy-duty lead-acid battery, you should expect the instrument to operate for around a week without recharging. If you prefer, you can power the 3ESP Compact directly from the connector on the top panel (see Chapter 6, page 46.) A power management module can be installed as an option, which allows the 3ESP Compact to operate from a V supply range. This module also cuts the input power to the sensor electronics if it drops below 10.5 V, to minimize discharge from battery-operated installations. Units with serial numbers beginning T33 are provided with a wide input range DC-DC converter, and can be powered from a V supply. The 3ESP Compact draws a nominal current of 75 ma from a 12 V supply when in use. During locking and unlocking of the sensor masses, this current rises briefly to 600 ma. It is recommended that you carry a spare 12 V battery when visiting an installation for maintenance, in case the sensor needs to be moved and the on-site batteries no longer have sufficient charge to perform the locking procedure. Signal output The sensors output voltages representing ground velocity on floating differential lines. The breakout box provides a RECORDER connector November
10 for attaching to a recording system or digitizer. You can use any multichannel recording system, provided that it has high-impedance floating differential inputs. If you are using a Güralp Systems digitizer, you can connect the instrument directly to the digitizer without using the breakout box; power will be supplied through the digitizer, which can also activate the sensor control lines. The breakout box also provides a CONTROL output, which can be connected to the Handheld Control Unit. This device lets you monitor output signals from the instrument, and perform on-site calibration. For more information, see Section 4.1, page Installation notes The goal of any seismic installation is to ensure that wave-trains arriving at the instrument accurately reflect the internal motion of subsurface rock formations. To achieve this, the seismometer and its emplacement need to be considered as a mechanical system, which will have its own vibrational modes and resonances. These frequencies should be raised as high as possible so that they do not interfere with true ground motion: ideally, beyond the range of the instrument. In particular, the sensor needs to be protected against environmental factors such as fluctuations in temperature, turbulent air flow around walls or trees, or around sharp corners or edges in the immediate vicinity of the sensor; vibration caused by equipment in or near the installation, particularly computer equipment; and vibration caused by heavy machinery (even at a distance), or by overhead power lines. In seismic vaults, instruments are often installed on piers. It is important to ensure that the interface between the pier and the floor does not introduce noise, and that the pier itself does not have resonant frequencies within the passband. Ideally, a seismic pier will be significantly wider than it is high (to minimize flexing) and will form a single piece with the floor, e.g. by moulding a poured concrete floor with a wooden frame. 10
11 Operator's guide Many situations do not allow for the construction of a seismic vault. For example, you may need to deploy quickly to monitor the activity of a volcano showing signs of rejuvenation, or to study the aftershocks of a major earthquake; or the site itself may be too remote to ship in construction equipment. Temporary installations can be protected against spurious vibrations by selecting a suitable site, placing the instrument in a protective enclosure (an open-sided box of 5 cm expanded polystyrene slabs, placed over the instrument and taped down to exclude draughts, makes an excellent thermal shield), standing the sensor on bedrock where possible, or at least deep in well-compacted subsoil; clearing the floor of the hole of all loose material; and using as little extra mass as possible in preparing the chamber. After installation, the instrument case and mounting surface will slowly return to the local temperature, and settle in their positions. This will take around four hours from the time installation is completed. If you require long-period recording, you should re-zero the instrument after this time. 2.3 Installing in vaults You can install a 3ESP Compact in an existing seismic vault with the following procedure: 1. Unpack the sensors from their container, saving the shipping boxes for later transportation. 2. Prepare the mounting surface, which should be smooth and free of cracks. Remove any loose particles or dust, and any pieces of loose surfacing. This ensures good contact between the instrument's feet and the surface. 3. If it is not already present, inscribe an accurate North-South line on the mounting surface. 4. Place the sensor over the scribed line, so that the brass and steel November
12 pointers are aligned with the marked directions, with the brass pointer facing North. This can be done by rotating the base of the sensor whilst observing it from above. The brass pointer can be found next to one of the feet. If you cannot easily see the pointers, you should align the sensor using the north arrow on the handle. However, the alignment of the handle with the sensors inside is less accurate than the metal pointers, so they should be used wherever possible. 5. The top panel of the 3ESP Compact includes a spirit level. Level the sensor using each of the adjustable feet of the instrument in turn, until the bubble in the spirit level lies entirely within the inner circle. (The instrument can operate with up to 2 of tilt, but with reduced performance.) The feet are mounted on screw threads. To adjust the height of a foot, turn the brass locking nut anticlockwise to loosen it, and rotate the foot so that it screws either in or out. When you are happy with the height, tighten the brass locking nut clockwise to secure the foot. When locked, the nut should be at the bottom of its travel for optimal noise performance. 6. Connect the sensor to a breakout box, or a Güralp digitizer if you are using one. 7. Connect a 12 V power supply, either directly or through the breakout box or digitizer. 8. Unlock the sensor. If you have a breakout box or handheld control unit, you can do this by holding the ENABLE and UNLOCK buttons on the unit down together for 7 seconds. The BUSY LED will start flashing, and then go out. 12
13 Operator's guide Alternatively, if you are using a DM24 digitizer and Scream!, right-click on the digitizer's entry in Scream! and select Control... Click on the Mass control tab, followed by Unlock. (If the Mass control tab is unavailable, check the sensor type in the Sensor type tab, apply, and open a new Control window.) Alternatively, if you are using a DM24 digitizer and a DCM, navigate to the Actions Digitizer Setup Port x page for the digitizer and click on the Unlock instrument button at the bottom of the page. After this point, you should be careful not to tilt the instrument, or you may damage it. 9. Check the mass position outputs using a digital multimeter, digitizer or the handheld control units. Re-centre the masses if required. If you have a breakout box or handheld control unit, you can do this by holding the ENABLE and CENTRE buttons on the unit down together for 7 seconds. The BUSY LED will start flashing, and then go out Alternatively, if you are using a DM24 digitizer and Scream!, right-click on the digitizer's entry in Scream! and select Control... Click on the Mass control tab, followed by Centre. Alternatively, if you are using a DM24 digitizer and a DCM, navigate to the Actions Digitizer Setup Port x page for the digitizer and click on the Centre instrument button at the bottom of the page. (If the Mass control tab is unavailable, make sure the correct sensor type is chosen in the Sensor type tab, apply, and open a new Control window.) 10.Cover the instrument with thermal insulation, for example, a 5 cm expanded polystyrene box. This will shield it from thermal fluctuations and convection currents in the vault. It also helps to stratify the air in the seismometer package. Position the thermal insulation carefully so that it does not touch the sensor package. November
14 11.Ensure that the sensor cable is loose and that it exits the seismometer enclosure at the base of the instrument. This will prevent vibrations from being inadvertently transmitted along the cable. 2.4 Installing in pits For outdoor installations, high-quality results can be obtained by constructing a seismic pit. Depending on the time and resources available, this type of installation can suit all kinds of deployment, from rapid temporary installations to medium-term telemetered stations. Ideally, the sensor should rest directly on the bedrock for maximum coupling to surface movements. However, if bedrock cannot be reached, good results can be obtained by placing the sensor on a granite pier on a bed of dry sand. 1. Prepare a hole of cm depth to compacted subsoil, or down to the bedrock if possible. 14
15 Operator's guide 2. On granite or other hard bedrock, use an angle grinder to plane off the bedrock at the pit bottom so that it is flat and level. Stand the instrument directly on the bedrock, and go to step On soft bedrock or subsoil, you should install a pier as depicted below. 4. Pour a layer of loose, fine sand into the pit to cover the base. The type of sand used for children's sand-pits is ideal, since the grains are clean, dry and within a small size range. On top of the sand, place a smooth, flat granite plinth around 20 cm across, and shift it to compact the sand and provide a near-level surface. Placing a granite plinth on a sand layer increases the contact between the ground and the plinth, and improves the performance of the instrument. There is also no need to mix concrete or to wait for it to set, as in step Alternatively, if time allows and granite is not available, prepare November
16 a concrete mix with sand and fine grit, and pour it into the hole. Agitate ( puddle ) it whilst still liquid, to allow it to flow out and form a level surface, then leave to set. Follow on from step 7. Puddled concrete produces a fine-textured, level floor for emplacing the seismometer. However, once set hard, the concrete does not have the best possible coupling to the subsoil or bedrock, which has some leeway to shift or settle beneath it. 6. Alternatively, for the most rapid installation, place loose soil over the bottom of the pit, and compact it with a flat stone. Place the seismometer on top of this stone. This method emulates that in step 3, but can be performed on-site with no additional equipment. 7. Set up the instrument as described in the previous Section. 8. The instrument must now be shielded from air currents and temperature fluctuations. This is best done by covering it with a thermal shield. An open-sided box of 5 cm expanded polystyrene slabs is recommended. If using a seismic plinth on sand (from steps 3 4 or 5), ensure that the box is firmly placed in the sand, without touching the plinth at any point. In other installations, tape the box down to the surface to exclude draughts. 9. Alternatively, if a box is not available, cover the instrument with fine sand up to the top. The sand insulates the instrument and protects it from thermal fluctuations, as well as minimizing unwanted vibration. 10.Ensure that the sensor cable is loose and that it exits the seismometer enclosure at the base of the instrument. This will prevent vibrations from being inadvertently transmitted along the cable. 11.Cover the pit with a wooden lid, and back-fill with fresh turf. Other installation methods The recommended installation methods have been extensively tested in a wide range of situations. However, past practice in seismometer installation has varied widely. 16
17 Operator's guide Some installations introduce a layer of ceramic tiles between a rock or concrete plinth and the seismometer (left): However, noise tests show that this method of installation is significantly inferior to the same concrete plinth with the tiles removed (right). Horizontal sensors show shifting due to moisture trapped between the concrete and tiling, whilst the vertical sensors show pings as the tile settles. Other installations have been attempted with the instrument encased in plaster of Paris, or some other hard-setting compound (left): Again, this method produces inferior bonding to the instrument, and moisture becomes trapped between the hard surfaces. We recommend the use of fine dry sand (right) contained in a box if necessary, which can also insulate the instrument against convection currents and temperature changes. Sand has the further advantage of being very easy to install, requiring no preparation. Finally, many pit installations have a large space around the seismometer, covered with a wooden roof. Large air-filled cavities are susceptible to currents which produce lower-frequency vibrations, and sharp edges and corners can give rise to turbulence. We recommend that a wooden box is placed around the sensor to protect it from these currents. Once in the box, the emplacement may be backfilled with fresh turf to insulate it from vibrations at the surface, or simply roofed as before. November
18 By following these guidelines, you will ensure that your seismic installation is ready to produce the highest quality data. 2.5 Rapid installation This section details a method of deploying 3ESP Compact instruments with the minimum of additional equipment. This is recommended for situations where seismic instrumentation needs to be installed very quickly, e.g. to study a resumption of volcanic activity, or where difficulty of access to the site prevents you from constructing a full seismic pit. You should always construct a pit if possible, since the data produced will be of significantly higher quality. 1. Prepare a hole of cm depth to compacted subsoil, or down to the bedrock if possible. 2. Clean the hole down to the bottom, and remove any loose material from the mouth. Ensure that the bottom of the hole is relatively flat. 3. If the bottom of the hole is made of hard rock, you may need to 18
19 Operator's guide put in some loose sand or soil so that the sensor can be levelled. 4. Connect the sensor to cables for the GPS unit and power source. 5. Carefully insert the instrument into the hole, protected by a tough plastic bag to keep water out. Use a bag strong enough to bear the weight of the sensor and breakout box, so that it can be recovered easily. 6. Press the sensor down firmly into the soil, without tapping or hitting it. 7. Check the bubble level on top of the instrument package. Adjust the instrument's position if necessary so that the bubble lies entirely within the black circle. 8. Pack soil or sand around the instrument to hold it steady. Make sure the soil or sand is firmly compacted and not at all loose. 9. Recheck the bubble level. If you cannot adjust the soil packing at this stage and the sensor is not level, you will need to clear the hole and restart from step Power the sensor through the breakout box, and unlock the masses by holding down the ENABLE and UNLOCK buttons for 7 seconds. 11.Place the breakout box and any excess cable on top of the sensor, inside the plastic bag. November
20 12.Group the cables coming from the bag for a distance of about 1 m, and keep them together with insulating tape. 13.Tie the top of the package and fold it over so that water cannot get in. Leave any excess cable within the bag. 14.Cover the installation with soil or sand until it is no longer visible. 15.Attach a GPS unit to the cable coming from the sensor. Seal the connection between the data cable and the GPS unit's IEEE 1394 cable inside a plastic bag to protect it from moisture. 16.Position the GPS unit so that it has a good view of the sky. Bury the cable and connector package so that they cannot be seen. 20
21 Operator's guide 17.If possible, place the GPS near the instrument so that it can be found more easily, and the connector package near the GPS so you can retrieve data from the instrument without affecting the installation. 18.If you are using a battery as a power source, dig a second hole for it. This hole does not need to be as deep as the pit for the instrument perhaps 10 cm plus the height of the battery. 19.Attach the sensor power cable to the battery, and wrap it in another plastic bag. Place the bag in the hole. 20.Tie the bag and fold over, to make the battery as waterproof as possible. 21.Bury the power cable between the battery and the instrument, and compact soil or sand around the bag. 22.Fill in and cover the hole so that it is not visible. November
22 Recovery Care should be taken when recovering the 3ESP Compact, since tapping or banging it can cause damage to the sensors inside. The following instructions assume that you have installed the instrument following the steps above. 1. Find the GPS receiver, which will be the only feature visible from the surface, and follow the buried data cable from it to the instrument. 2. Carefully remove earth from the hole until you find the power cable coming from the instrument. 3. Follow the power cable to the battery pit, and carefully dig away the soil to reveal the battery about 10 cm from the surface. 4. Disconnect the power cable from the battery. (With the power off, the sensor is less likely to suffer electrical damage during recovery.) 5. Return to the location of the sensor, and dig down to it. You should be able to remove a spade's head depth of soil without hitting the instrument. Beyond that, using a small hand shovel, follow the wires and carefully remove the remaining soil until you can see the plastic bag. Take special care not to damage the wires, which should be tied together in the vicinity of the bag. 6. Carry on removing soil, either with your hands or (very carefully!) with the shovel, until the whole bag is uncovered to about half the height of the instrument. 7. If the hole is relatively dry, open the bag and remove the breakout box and cabling. Power the sensor through the breakout box, and lock the sensor masses by holding down the ENABLE and LOCK buttons for 7 seconds. Lift the instrument out by its handle. Do not lift the instrument by any of the attached cables. Straining the cables may result in invisible damage, making future installations unreliable. 8. Alternatively, if the hole is waterlogged, carefully lift out the entire bag in one piece, and remove the contents at the surface. You should lock the sensor masses as soon as you can, and in any case before transporting the instrument. 22
23 Operator's guide 2.6 Installing in postholes The 3ESP Compact is suitable for installation in postholes. In soft subsoil, a hole 2 4 m deep and 20 cm wide can be conveniently excavated using a tractor-mounted or hand-operated posthole auger. To minimize surface effects, you should ensure that the hole is at least 1 m deeper than the length of the instrument, and preferably somewhat more. Since the hole has no lining, it may occasionally flood. However, most soil types are sufficiently permeable to allow water to soak away, leaving the packing material moist. To install a 3ESP Compact in a posthole: 1. Clean the posthole, making sure there is no loose material around the mouth of the hole or on its base. 2. Prepare the instrument package, making sure the inclinometer is visible, and attach it to a winch or hoist by clamping a light steel cable to the centre of the handle so that the package hangs vertically. Connect the signal cable to the instrument. 3. Add packing material to the hole to about 15 cm depth. Fine crushed rock, with a high proportion of rock flour and fine particles, makes excellent packing material. Alternatively, a mixture of 3 mm grade angular coarse grit with around 30% medium grit gives good results. Moisten the packing material in the hole and ram firm. 4. Lower the instrument to the bottom of the hole, but without slackening the lifting cable. 5. Fill more packing material around the instrument for about 30 cm, moisten, and ram firm. 6. Use the inclinometer to check that the instrument remains within its tilt tolerance (± 2 ). 7. Continue filling, moistening and packing until the instrument is buried, checking that the tilt remains within tolerance. 8. Release the strain on the lifting cable, and allow the packing material to settle for 24 hours. 9. If all is well after the settling period, release the lifting tackle, November
24 coil a tail of the lifting wire into the top of the hole and backfill almost to the surface. 10.Ensure that the signal cable is slack, and fix it to a support at the top of the hole. 11.Ram a split wooden bung into the top of the hole, and cover with sandbags. 12.Attach the signal cable to your recording equipment or breakout box. Power the sensor, and unlock it. Carry out preliminary tests using a handheld control unit, if required. 24
25 Operator's guide 3 Calibrating the 3ESP Compact 3.1 The calibration pack All Güralp sensors are fully calibrated before they leave the factory. Both absolute and relative calibration calculations are carried out. The results are given in the calibration pack supplied with each instrument: Works Order : The Güralp factory order number including the instrument, used internally to file details of the sensor's manufacture. Serial Number : The serial number of the instrument Date : The date the instrument was tested at the factory. Tested By : The name of the testing engineer. There follows a table showing important calibration information for each component of the instrument, VERTICAL, NORTH/SOUTH, and EAST/WEST. Each row details: Velocity Output (Differential) : The sensitivity of each component to velocity at 1 Hz, in volts per m/s. Because the 3ESP Compact uses balanced differential outputs, the signal strength as measured between the +ve and ve lines will be twice the true sensitivity of the instrument. To remind you of this, the sensitivities are given as 2 (single-ended sensitivity) in each case. Mass Position Output : The sensitivity of the mass position outputs to acceleration, in volts per m/s². These outputs are single-ended and referenced to signal ground. Feedback Coil Constant : A constant describing the characteristics of the feedback system. You will need this constant, given in amperes per m/s², if you want to perform your own calibration calculations (see below.) Power Consumption : The average power consumption of the sensor during testing, given in amperes and assuming a 12 V supply. Calibration Resistor : The value of the resistor in the calibration circuit. You will need this value if you want to perform your own calibration calculations (see below.) November
26 Poles and zeroes Most users of seismometers find it convenient to consider the sensor as a black box, which produces an output signal V from a measured input x. So long as the relationship between V and x is known, the details of the internal mechanics and electronics can be disregarded. This relationship, given in terms of the Laplace variable s, takes the form ( V / x ) (s ) = G A H (s ) In this equation G is the acceleration output sensitivity (gain constant) of the instrument. This relates the actual output to the desired input over the flat portion of the frequency response. A is a constant which is evaluated so that A H (s) is dimensionless and has a value of 1 over the flat portion of the frequency response. In practice, it is possible to design a system transfer function with a very wide-range flat frequency response. The normalising constant A is calculated at a normalising frequency value fm = 1 Hz, with s = j fm, where j = 1. H (s) is the transfer function of the sensor, which can be expressed in factored form: In this equation zn are the roots of the numerator polynomial, giving the zeros of the transfer function, and pm are the roots of the denominator polynomial giving the poles of the transfer function. In the calibration pack, G is the sensitivity given for each component on the first page, whilst the roots zn and pm, together with the normalising factor A, are given in the Poles and Zeros table. The poles and zeros given are measured directly at Güralp Systems' factory using a spectrum analyser. Transfer functions for the vertical and horizontal sensors may be provided separately. 26
27 Operator's guide Frequency response curves The frequency response of each component of the 3ESP Compact is described in the normalised amplitude and phase plots provided. The response is measured at low and high frequencies in two separate experiments. Each plot marks the low-frequency and high-frequency cutoff values (also known as 3 db or half-power points). If you want to repeat the calibration to obtain more precise values at a frequency of interest, or to check that a sensor is still functioning correctly, you can inject calibration signals into the system using a Güralp digitizer or your own signal generator, and record the instrument's response. Obtaining copies of the calibration pack Our servers keep copies of all calibration data that we send out. In the event that the calibration information becomes separated from the instrument, you can obtain all the information using our free service. Simply [email protected] with the serial number of the instrument in the subject line, e.g. From: your@ .net To: [email protected] Subject: T3A15 November
28 The server will reply with the calibration documentation in Word format. The body of your will be ignored. 3.2 Calibration methods Velocity sensors such as the 3ESP Compact are not sensitive to constant DC levels, either as a result of their design or because of an interposed high-pass filter. Instead, three common calibration techniques are used. Injecting a step current allows the system response to be determined in the time domain. The amplitude and phase response can then be calculated using a Fourier transform. Because the input signal has predominantly low-frequency components, this method generally gives poor results. However, it is simple enough to be performed daily. Injecting a sinusoidal current of known amplitude and frequency allows the system response to be determined at a spot frequency. However, before the calibration measurement can be made the system must be allowed to reach a steady state; for low frequencies, this may take a long time. In addition, several measurements must be made to determine the response over the full frequency spectrum. Injecting white noise into the calibration coil gives the response of the whole system, which can be measured using a spectrum analyser. You can perform calibration either using a Güralp DM24 digitizer, which can generate step and sinusoidal calibration signals, or by feeding your own signals into the instrument through a handheld control unit. Before you can calibrate the instrument, its calibration relays need to be activated by pulling low the CAL ENABLE line on the instrument's connector for the component you wish to calibrate. Once enabled, a calibration signal provided across the CAL SIGNAL and SIGNAL GROUND lines will be routed through the feedback system. You can then measure the signal's equivalent velocity on the sensor's output lines. Güralp Handheld Control Units provide a switch for activating the CAL ENABLE line. 3.3 Calibration with Scream! Güralp digitizers provide calibration signal generators to help you set 28
29 Operator's guide up your sensors. Calibration is most easily done through a PC running Güralp's Scream! software. Depending on the digitizer type, sine-wave, step and broadband noise signal generators may be available. In this section, broadband noise calibration will be used to determine the complete sensor response in one action. Please refer to the digitizer's manual for information on other calibration methods. 1. In Scream!'s main window, right-click on the digitizer's icon and select Control... Open the Calibration pane. 2. Select the calibration channel corresponding to the instrument, and choose Broadband Noise. Select the component you wish to calibrate, together with a suitable duration and amplitude, and click Inject now. A new data stream, ending Cn (n = 0 7) or MB, should appear in Scream!'s main window containing the returned calibration signal. November
30 3. Open a Waveview window on the calibration signal and the returned streams by selecting them and double-clicking. The streams should display the calibration signal combined with the sensors' own measurements. If you cannot see the calibration signal, zoom into the Waveview using the scaling icons at the top left of the window or the cursor keys. Drag the calibration stream Cn across the Waveview window, so that it is at the top. 4. If the returning signal is saturated, retry using a calibration signal with lower amplitude, until the entire curve is visible in the Waveview window. 5. If you need to scale one, but not another, of the traces, rightclick on the trace and select Scale... You can then type in a suitable scale factor for that trace. 6. Pause the Waveview window by clicking on the icon. 7. Hold down SHIFT and drag across the window to select the calibration signal and the returning component(s). Release the mouse button, keeping SHIFT held down. A menu will pop up. Choose Broadband Noise Calibration. 8. The script will ask you to fill in sensor calibration parameters for each component you have selected. 30
31 Operator's guide Most data can be found on the calibration sheet for your sensor. Under Instrument response, you should fill in the sensor response code for your sensor, according to the table below. Instrument Type should be set to the model number of the sensor. If the file calvals.txt exists in the same directory as Scream!'s executable (scream.exe), Scream! will look there for suitable calibration values. A sample calvals.txt is supplied with Scream!, which you can edit to your requirements. Each stream has its own section in the file, headed by the line [instrument-id]. The instrument-id is the string which identifies the digitizer in the left-hand pane, e.g. GURALP-DEMO. It is always 6 characters (the system identifier) followed by a dash, then 4 characters (the serial number.) For example: [instrument-id] Serial-Nos=T3X99 VPC=3.153,3.147,3.159 G=1010,1007,1002 COILCONST= , , CALVPC=3.161 CALRES=51000 TYPE=sensor-type RESPONSE=response-code 9. Click OK. The script will return with a graph showing the responsivity of the sensor in terms of amplitude and phase plots for each component (if appropriate.) The accuracy of the results depends on the amount of data you have selected, and its sample rate. To obtain good-quality results at low frequency, it will save computation time to use data collected at a lower sample rate; although the same information November
32 is present in higher-rate streams, they also include a large amount of high-frequency data which may not be relevant to your purposes. The broadband noise calibration script automatically performs appropriate averaging to reduce the effects of aliasing and cultural noise. Sensor response codes Sensor Sensor type code Units (V/A) CMG-5T or 5TD, DC 100 Hz response CMG-5_100HZ A CMG-40T-1 or 6T-1, 1 s 100 Hz response CMG-40_1HZ_50HZ V CMG-40_1S_100HZ V CMG-40_2S_100HZ V CMG-40T-1 or 6T-1, 2 s 100 Hz response 32 CMG-40T-1 or 6T-1, 10 s 100 Hz CMG-40_10S_100HZ response V CMG-40, 20 s 50 Hz response CMG-40_20S_50HZ V CMG-40, 30 s 50 Hz response CMG-40_30S_50HZ V CMG-3T or 3ESP, 30 s 50 Hz response CMG-3_30S_50HZ V CMG-40, 60 s 50 Hz response CMG-40_60S_50HZ V CMG-3T or 3ESP, 60 s 50 Hz CMG-3_60S_50HZ V
33 Operator's guide Sensor type code Units (V/A) CMG-3T or 3ESP, 100 s 50 Hz response CMG-3_100S_50HZ V CMG-3T or 3ESP, 120 s 50 Hz response CMG-3_120S_50HZ V CMG-3T, 360 s 50 Hz response CMG-3_360S_50HZ V CMG-3TB or 3V / 3ESP borehole, 30 s 50 Hz response CMG-3B_30S_50HZ V CMG-3TB or 3V / 3ESP borehole, 100 s 50 Hz response CMG-3B_100S_50HZ V CMG-3TB or 3V / 3ESP borehole, 120 s 50 Hz response CMG-3B_120S_50HZ V Sensor response 3.4 Calibration with a handheld control unit If you prefer, you can inject your own calibration signals into the system through a handheld control unit. The unit includes a switch which activates the calibration relay in the seismometer, and 4 mm banana sockets for an external signal source. As above, the equivalent input velocity for a sinusoidal calibration signal is given by v=v/2πfrk where V is the peak-to-peak voltage of the calibration signal, f is the signal frequency, R is the magnitude of the calibration resistor and K is the feedback coil constant. R and K are both given on the calibration sheet supplied with the 3ESP Compact. The calibration resistor is placed in series with the transducer. Depending on the calibration signal source, and the sensitivity of your recording equipment, you may need to increase R by adding further resistors to the circuit. 3.5 The coil constant The feedback coil constant K is measured at the time of manufacture, and printed on the calibration sheet. Using this value will give good results at the time of installation. However, it may change over time. November
34 The coil constant can be determined by tilting the instrument and measuring its response to gravity. To do this, you will need apparatus for measuring tilt angles accurately. 1. Measure the acceleration due to gravity, g, at your location. 2. Tilt the instrument slightly, and measure its attitude and the gain of the mass position output for the component you wish to calibrate. 3. Repeat this measurement for several tilt angles. 4. For the vertical sensor, the input acceleration is given by a = g sin φ, whilst for the horizontal sensor, it is a = g ( 1 cos φ ). Calculate the input acceleration for each of the tilt angles used, and plot a graph of mass position output against input acceleration. 5. The gradient of the line obtained gives the sensitivity of the coil (in V/m/s2, if g was measured in m/s2 and the mass position in V.) 6. The coil constant K is equal to this sensitivity divided by the value of the displacement feedback resistor, given on the calibration sheet. 34
35 Operator's guide 4 Accessories 4.1 The handheld control unit This portable control unit provides easy access to the seismometer's control commands, as well as displaying the output velocity and mass position (i.e. acceleration) on an analogue meter. It takes input from the 26-pin connector at the bottom, and repeats it at the connector on the side for connection to further equipment. The handheld control unit can be sited up to 50 m from the breakout box. The meter The meter at the top of the unit allows you to monitor the voltage outputs of the instrument. Using the knob below, you can select either the mass position output or the velocity output, for each of the three components. There is also a RANGE switch allowing you to alter the sensitivity of the meter. November
36 Calibration The handheld control unit can be used to calibrate the 3ESP Compact. To activate the calibration relays, turn the knob to the component you wish to calibrate, and introduce a calibration signal on the CAL SIG banana sockets. Control commands You can use the handheld control unit to centre, lock and unlock the sensor masses. To unlock the sensor masses, press the ENABLE switch down, and the LOCK/UNLOCK switch up simultaneously for 7 seconds. The BUSY LED will light. All three masses are unlocked, each in turn. The sensor then automatically moves on to centre the masses, during which time the BUSY LED will flash. When the BUSY LED goes out, the instrument is ready for use. You should not attempt to move the instrument without relocking the masses. To lock the sensor masses, press the ENABLE and LOCK/UNLOCK switches down simultaneously for 7 seconds. When the BUSY LED goes out, the instrument is ready for transportation. To re-centre the sensor masses, press the ENABLE and CENTRE switches down simultaneously for 7 seconds. When the BUSY LED stops flashing, the centring process has finished. You may need to initiate several rounds of centring before the instrument is ready; when no more centring is required, pressing the ENABLE and CENTRE buttons has no effect. Outputs The remaining banana sockets provide easy access to the output voltages of the instrument. For each component (vertical, N/S and E/W): 36 the left-hand two sockets expose the balanced differential outputs representing ground velocity, and the right-hand socket exposes the mass position (acceleration) output.
37 Operator's guide Ground references for each of these voltages are provided at the bottom of the unit. Ensure that you do not connect either side of a differential output to ground. November
38 5 Inside the 3ESP Compact 5.1 The sensors The horizontal and vertical sensors are similar in design. The inertial mass in both cases consists of a transducer coil and a leaf-spring suspended boom which swings on a frictionless hinge. A triangular spring supports the weight of the mass; in the vertical sensor this spring is pre-stressed, with a natural period around 0.5 s, whilst the horizontal sensor has an unstressed flat spring with a natural period around 1 s. sensors have no spurious resonances below 140 Hz, and weigh around 180 g. The small boom size and stiff springs allow three independent instruments to be mounted within the casing, together with all the associated feedback electronics. The 3ESP Compact functions by monitoring the position of each mass with a capacitative position sensor. The three sensors are identical. Signals from the sensors are fed into an electronic processing unit, which is mounted in a screened compartment above the mechanical components (see below for details on the feedback circuitry.) When the instrument is being transported, the masses are locked securely in their frames so as to relieve strain on the support hinges. This locking is performed by a small motor-driven clamp in response to a signal from the surface controller unit. Before using the instrument, the boom of the vertical sensor must be levelled and the bases of the horizontal sensors tilted, so that the masses are centred in their equilibrium positions. These adjustments are made by small DC motors controlled remotely. The signal voltages output by the 3ESP Compact are proportional to ground velocity, and are transmitted from the instrument on balanced differential lines. In addition, mass position signals are sent as singleended circuits referred to analogue ground on the output plug. The 3ESP Compact also receives control signals, which are used to clamp and unclamp the masses, and to run the motors which level and centre the instrument once in position. Finally, a line is provided for you to apply a calibrating voltage to the force transducers, thereby measuring the deflection sensitivity. 5.2 The control system The internal operations of the 3ESP Compact are supervised by a 38
39 Operator's guide control microprocessor, which drives the mass clamping and centring adjustment motors. It responds to commands sent on three input lines by grounding for seconds. The signals you can send to the microprocessor are termed LOCK, UNLOCK, and CENTRE. Each command acts on the vertical, N/S and E/W masses in turn. The microprocessor prevents the system from attempting incompatible actions (e.g. centring when the masses are clamped.) While a command is taking place, the BUSY LED will flash; you can use this for diagnostic purposes. See the description of each command for full details. When no command is active, i.e. all three lines are high, the control microprocessor goes into a power-saving mode. In routine operation, the lines are controlled from the breakout box, Handheld Control Unit or digitizer. If you send control signals to the 3ESP Compact manually, you must ensure that the lines are pulled high after sending the signal, or the equipment may be damaged. A biased-off type switch can be used for this purpose. LOCK This command locks the vertical mass and clamps the horizontal sensors by tilting them up to their end stops. If LOCK is activated when the masses are already locked, the processor will unlock them and attempt to lock again. This is useful if you suspect that the locking procedure has failed. In detail, the process acts as shown in the following graph. The top three streams are the mass position outputs of each component (Z, N/S and E/W, respectively), whilst the bottom one represents the state of the BUSY LED (up = on). November
40 In the three-stage process, the vertical mass is locked with a motorised micrometer, and the N/S and E/W sensor bases are tilted to their end stops. At some point during each tilting stage, the position of the relevant mass will flip to one or other side. With the horizontal bases tilted, gravity will keep the masses pressed against their end stops, effectively locking them in place. Because the 3ESP Compact mass assembly is designed for a degree of robustness, no further locking is required. The BUSY LED is lit during each stage, but goes out briefly between stages, allowing you to follow the progress of the lock. UNLOCK This command unlocks the sensor masses and prepares the instrument to begin operating. If UNLOCK is activated when the masses are already unlocked, the processor will lock them and attempt to unlock again. This is useful if you suspect that the locking procedure has failed. During the UNLOCK procedure, the instrument automatically performs a round of centring for each component. 40
41 Operator's guide Again, you can use the BUSY LED to monitor the progress of unlocking. 1. The instrument checks to see whether the vertical mass is locked, and unlocks it if necessary. 2. The vertical mass is centred by applying pulses to the motor. This stage is often very short, since the vertical mass is locked near its central position. 3. The instrument checks the N/S sensor and base, and unlocks the sensor. 4. The N/S sensor base is tilted to its level position. This process takes rather longer. At some point during this stage, the mass may flip to the other side (as seen in the green trace.) 5. The N/S sensor mass is centred by applying pulses to the motor. This stage will take longer than stage 2, since it must move the mass all the way from its end stop. As the mass nears the centre, the control circuit spaces out the pulses. 6. The E/W component is checked and unlocked. 7. The E/W sensor base is tilted to its level position as in step The E/W sensor mass is centred as in step 5. After unlocking, the instrument automatically performs a round of centring (see below). November
42 CENTRE This command re-centres the masses. If the masses are clamped, or if the sensor mass positions do not exceed ± 1.2 V, the CENTRE command does nothing. Otherwise, it attempts to zero the output of the vertical, N/S and E/W sensors in sequence by exerting small extra forces on the boom. For the vertical sensor, a motor-driven adjuster presses a small spring lever against the boom until the mass position sensor indicates an offset close to zero. In the case of the horizontal sensors, the sensor frame is tilted on its base plate. Again, the controller monitors the mass position sensor and stops the centring process once it reaches its lowest offset. This graph shows a typical centring process: 1. The BUSY LED pulses to indicate that it is centring the Z component. Each pulse corresponds to a small force on the mass. The pulses become briefer as this goes on, until a pulse is missed, signifying that no corrective impulse is needed. 2. The N/S component follows in the same way. If the true mass position is outside the range of the output, you may not see the output change for some time. If the pulses cause the mass to overshoot the central position, a second group of pulses in the opposite direction is applied to bring it into line. 3. The E/W component follows in the same way. All three masses are now centred and the process completes. After the sensor unlocks the masses, the first round of centring has to move the N/S and E/W components all the way from their end stops, 42
43 Operator's guide whilst the Z component is often closer to the proper position. Because of this, the first Z centring operation takes much less time than the others, and you may not notice it. After successful centring, the mass position outputs should be in the range V. If the centring process leaves the mass position outputs above ±1.1 V, you should start another centring cycle by activating the CENTRE command again. You will probably need to initiate the centring process several times before the masses are adequately centred. 5.3 The feedback system The output from a modern broadband seismometer does not depend on the natural characteristics of the instrument. Instead, the period and damping of the sensor is completely determined by a feedback loop which applies a force to the sensor mass opposing any motion. The force required to restrain the movement of the mass can then be used to measure the inertial force which it exerts as a result of ground motion. All CMG-3 series units are based on these general principles. The capacitative position sensor for each mass produces a voltage proportional to the displacement of the mass from its equilibrium position. After amplification, this voltage generates a current in the force transducer coil which tends to force the mass back toward equilibrium. The feedback loop has a sufficiently high gain to cancel the motion of the mass. Since the mass is not moving, the forces acting on it must be balanced; the feedback voltage then directly measures the force, and hence the acceleration, which is being applied to the mass. The feedback loop introduces a phase shift, which must be carefully controlled if the instrument is to remain stable over its entire frequency range. This is achieved using compensation components in the forward and feedback paths. Force feedback seismometers of this type rely on the assumption that the force transducer produces a field of constant strength. The magnetic circuit and magnet/pole assembly in the 3ESP Compact are designed so that the field strength from the feedback transducer is constant over large deflections and current levels. In a feedback seismometer with a displacement transducer, it is essential to monitor the acceleration output. This provides the position of the displacement transducer and therefore also the mass position, as the displacement transducer is attached to the sensor inertial mass. The sensor should always be operated with the displacement transducer centred or nulled, so that the response to input acceleration November
44 is linear. There are two types of feedback system which can be used in a 3ESP Compact instrument, known as hybrid and conventional-response feedback. Hybrid feedback The hybrid feedback circuit contains a single capacitor in parallel with a resistor, resulting in a single dominant pole at Hz (30 s). Below this frequency, the response of the seismometer is flat to ground acceleration; above it, the response is flat to velocity. (Other values for the acceleration-velocity corner can be provided upon request.) Hybrid-feedback systems provide a stable response, particularly for portable systems, with a high saturation level at high frequencies and a high dynamic range at long periods. An active low-pass filter provides a high-frequency cutoff point at a frequency you specify. Without the filter, the velocity response is flat up to 100 Hz. Outside the feedback loop there is an active high-pass filter with a corner frequency of 0.01 Hz (100 s) or Hz (200 s), which serves to remove any DC offsets. Conventional-response feedback The conventional-response feedback system has an additional parallel feedback circuit, consisting of a non-inverting integrator in series with a resistor. This arrangement results in two poles at specified frequencies. The velocity response of a conventional-response system is defined by a transfer function identical to that of a conventional long-period sensor with a damping constant ζ of (1/ 2). 44
45 Operator's guide The seismometer can be supplied with an equivalent resonant frequency of Hz (30 s), 0.01 Hz (100 s) or Hz (120 s) as required. An active low-pass filter provides a high-frequency cutoff point at a frequency you specify. Comparisons The figures below plot the comparative response of a conventional velocity output broadband sensor and a hybrid output broadband sensor. The left-hand graph shows the response in terms of output against input acceleration in units of V/m/s2, whilst the right-hand graph is plotted in terms of output against input velocity, in V/m/s. November
46 6 Connector pinouts 6.1 Sensor and control unit pin output Models with a 26-pin mil-spec plug (02E-16-26P) have the following pin assignments. These are the same as the RECORDER and HCU connectors on the breakout box. Pin Function 46 A Velocity +ve, vertical channel B Velocity ve, vertical channel C Velocity +ve, N/S channel D Velocity ve, N/S channel E Velocity +ve, E/W channel F Velocity ve, E/W channel G Mass position, vertical channel J Mass position, N/S channel K BUSY LED L Mass position, E/W channel M Power ve (not used in sensors with internal DC-DC converters) N Signal ground P Calibration signal (all channels) R Calibration enable, vertical channel S Calibration enable, N/S channel T Calibration enable, E/W channel U Centre W Unlock X Lock Y Logic ground b Power ground c Power +ve
47 Operator's guide 6.2 Appendix A.2 DC POWER connector This is a standard 10-pin mil-spec plug (02E-12-10P). Pi n Function A 0V B +12 V DC supply H 12 V DC supply November
48 7 Specifications Hybrid sensors Velocity sensors Controls Mechanics and electronics Velocity output bandwidth Hz High pass filter output flat to acceleration 0.01 Hz spec* High pass filter output flat to velocity spec 50 Hz* Mass position output DC 0.1 Hz Velocity sensitivity 1400 V/m/s Acceleration sensitivity 2000 V/m/s2 Velocity output bandwidth spec 50 Hz* Mass position output DC spec Hz* Velocity sensitivity V/m/s Mass position sensitivity 1000 V/m/s2 Mass locking and unlocking remotely operated Mass centring automatic, microprocessor controlled Sensors 3 orthogonal sensors, each kg Lowest spurious resonance above 140 Hz Power 48 Total weight 8 kg Sensor transducer type capacitive displacement Feedback transducer type magnet/coil Connector pressure tight Temperature range with masses locked 35 to +75 C Operational temperature range 20 to +65 C** Supply V Current at 12 V DC 75 ma Current at 12 V DC during calibration 100 ma Current at 12 V DC during 330 ma
49 Operator's guide centring (average) Current at 12 V DC during locking and unlocking 490 ma *spec refers to the quoted frequency response value, e.g., for a 30 s sensor, the value of spec would be 30 s = Hz. **Temperatures below 20 C may be accommodated with additional care. Please consult Güralp Systems for advice. Because centring, locking, and unlocking consume varying amounts of power, it is recommended that you use a power supply capable of delivering 1 A at 12 V. November
50 8 Revision history C Redrawn diagrams B Updates; added revision history A New document
CMG-40T. Triaxial Broadband Seismometer. Operator's guide. Part No. MAN-040-0001
Triaxial Broadband Seismometer Part No. MAN-040-0001 Designed and manufactured by Güralp Systems Limited 3 Midas House, Calleva Park Aldermaston RG7 8EA England Proprietary Notice: The information in this
CMG-RTM Real-time Clock/ GPS Emulator
CMG-RTM Real-time Clock/ GPS Emulator Operator's Guide Part No. MAN-RTM-0003 Designed and manufactured by Güralp Systems Limited 3 Midas House, Calleva Park Aldermaston RG7 8EA England Proprietary Notice:
Subminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
Wind Direction Smart Sensor (S-WDA-M003)
(S-WDA-M003) The Wind Direction smart sensor is designed to work with HOBO Stations. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Station. All sensor parameters
i ChatterBox! Motorcycle Security
i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before
6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20
USE OF ELECTRICAL TEST EQUIPMENT Test equipment is necessary for determining proper set-up, adjustment, operation, and maintenance of electrical systems and control panels. The following is a general procedure
SELF INSTALLATION GUIDE
Ultrafast Fibre-optic Broadband SELF INSTALLATION GUIDE Gigaclear install permission July2012 v1.0 Before you begin Please make sure you have the correct length of cable. Bear in mind that you may need
Step by step guide to installing your own Ku Band satellite dish
Step by step guide to installing your own Ku Band satellite dish If you don't feel comfortable installing your own system, your local TV Aerial or Handyman can easily follow these helpful guidelines for
Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement
Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement This work instruction describes the methods and means for which to remove and reinstall optional scanner cable configurations
Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
PS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
Electrical Resonance
Electrical Resonance (R-L-C series circuit) APPARATUS 1. R-L-C Circuit board 2. Signal generator 3. Oscilloscope Tektronix TDS1002 with two sets of leads (see Introduction to the Oscilloscope ) INTRODUCTION
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
ALARM SYSTEM INSTALLATION GUIDE
ALARM SYSTEM INSTALLATION GUIDE Congratulations on the purchase of your Egardia alarm system. Egardia's website www.egardia.com Customer services Please visit www.egardia.com if you would like further
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
SEISMIC MONITORING & PROTECTION SYSTEMS
SEISMIC MONITORING & PROTECTION SYSTEMS PRODUCT GUIDE Seismic Transducers & Switches Nuclear Infrastructure Protection Structural & Environmental Monitoring Data Capture & Analysis 25 YEARS 1978-2003 PROTECTING
RACEAIR REMOTE PAGER SYSTEM
Computech Systems, Inc. 301-884-5712 30071 Business Center Dr. Charlotte Hall, MD 20622 RACEAIR REMOTE PAGER SYSTEM TM Introduction: Computech s RaceAir Remote Competition Weather Station with the Data
idex Manual Contact details Producer: FOCI BV. The Netherlands www.foci.nl [email protected]
idex USB Manual Contact details Producer: FOCI BV. The Netherlands www.foci.nl [email protected] 2 Index Index... 3 1. General... 4 2. Get started!... 5 3. First use... 7 4. FOCI idex Software... 14 5. Operating
RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G
Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions 1 Overview The objective is to replace the broken axis spring tensioner wire. This requires the following tasks: 1. Remove the seismometer
Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales
Installation information METTLER TOLEDO MultiRange Floor scales / Pit scales KC300/KCS300 KC600/KCS600 KD600/KD1500 KE1500/KE3000 KES1500/KES3000 KG3000/KG6000 KN1500 Floor scales / Pit scales Contents
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system 1017 2-way pager system
MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system 1017 2-way pager system Remote Control Motorcycle Alarm System Installation & Operation Instructions Sistema de Alarma de
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
Vision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems
Vision Engravers and Routers PRE-Installation Guide Revised: 8/19/2015 Vision Engravers and Routers PRE-Installation Guide All rights reserved. No parts of this work may be reproduced in any form or by
Model SETR-50 and SETR-51 Trim Tab Control
Model SETR-50 and SETR-51 Trim Tab Control Pictured above is the SETR-50 with black switches on a gray background. The SETR-51 is identical except for the color, wherein it has black switches on a black
* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system Remote Control Motorcycle Alarm System Installation & Operation Instructions Sistema de Alarma de
IMPORTANT SAFETY RULES TO FOLLOW
WARNING FLOOR & CARPET CLEANER Any piece of equipment can be dangerous if not operated properly. YOU are responsible for the safe operation of this equipment. The operator must carefully read and follow
R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide
R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide (=7ÔWÌ) 1307.7039.62 06 Test & Measurement Quick Start Guide This Quick Start Guide describes the following converter
EC DECLARATION OF CONFORMITY FOR MACHINES
EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) Manufacturer: Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 770 mod. operator is built to be integrated
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,
Equipment Manual. for. Operation of Automatic Polishing Plate Control on the PM5 Precision Lapping & Polishing Machine.
Equipment Manual for Operation of Automatic Polishing Plate Control on the PM5 Precision Lapping & Polishing Machine Ref: BE-01-53-5 PREFACE: PM5 auto-lap/pol MACHINES The PM5 auto-lap/pol features two
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
Andersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en
Mounting instructions Acceleration Transducer B12 B 26.B12.10 en B12 3 Contents Page Safety instructions.............................................. 4 1 Scope of supply..............................................
Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011
WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers Installation Guide February, 2011 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 [email protected] 1 Disclaimer The following warranty
Appendix C. Vernier Tutorial
C-1. Vernier Tutorial Introduction: In this lab course, you will collect, analyze and interpret data. The purpose of this tutorial is to teach you how to use the Vernier System to collect and transfer
SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9
SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9 Learning Goals: At the end of this lab, the student should have basic familiarity with the DataMan
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST 1 Permeability is a measure of the ease in which water can flow through a soil volume. It is one of the most important geotechnical parameters. However,
Building a simple seismometer
Building a simple seismometer Seismometers operate on the principle of inertia, i.e. a body at rest will tend to remain that way unless a force is applied to make it move. An ideal seismometer would be
Remote Head REMO ONE. Code 5750. Manual
Remote Head REMO ONE Code 5750 Manual by sachtler. All rights reserved Version: 1.2/09/05 Issue date: September 2005 Order no.: srh20t010a We want you to receive Sachtler products that are always state
Internal Modem Installation with Windows 95
Internal Modem Installation with Windows 95 You will need these items from your U.S. Robotics modem box: modem phone cord Plus: a screwdriver (not included) Determining Available Resources Your U.S. Robotics
Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement
Chapter 2 Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement 2.1 Introduction and Objectives This laboratory exercise involves the static calibration
Parallel Plate Capacitor
Parallel Plate Capacitor Capacitor Charge, Plate Separation, and Voltage A capacitor is used to store electric charge. The more voltage (electrical pressure) you apply to the capacitor, the more charge
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
Fiberstars Lighted Laminar Flow Fountain Installation Manual
Fiberstars Lighted Laminar Flow Fountain Installation Manual 79-15037-00 REV Xx http://www.fiberstars.com Page 1 of 8 SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
Attachment G-1: Pit Latrine Diagram. Fig E.1a: Pit Latrine. Fig E.1b: Plan View of Twin Pits
Attachment G-1: Pit Latrine Diagram Fig E.1a: Pit Latrine Fig E.1b: Plan View of Twin Pits Fig E.1c: Section of a water-sealed pan Fig E.1d: 3D view of Overflow Pipe Fig E.1e: 2D view of Overflow Pipe
PPM Users Manual Signature Software 01-12-00
PPM Users Manual Signature Software 0-2-00 PPM User Manual /8/02 Software Versions: 0.0.27 Contents. Introduction 2 2. Parameters 3 2. Overload Limit...4 2.2 Relative Upper Limit...4 2.3 Relative Lower
MoTeC USA GPS. Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4
MoTeC USA GPS Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4 MoTeC USA GPS Copyright Motec Systems USA 2008 The information in this document is subject to change without notice. While
3 LEVELLING & SURVEYING
3 LEVELLING & SURVEYING 3.1 General The primary reference at water-level recording stations is a set of stable bench-marks, installed in locations where their level should not change. Upon initial set-up
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
ERGL OWNER S MANUAL Elevated Runway Guard Light (ERGL)
ERGL OWNER S MANUAL Elevated Runway Guard Light (ERGL) September 5, 2008, Carmanah Technologies Corp. www.carmanah.com Sales Support: [email protected] Technical Support: [email protected]
Shunt lock function 3066
Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning
5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
Lab E1: Introduction to Circuits
E1.1 Lab E1: Introduction to Circuits The purpose of the this lab is to introduce you to some basic instrumentation used in electrical circuits. You will learn to use a DC power supply, a digital multimeter
Multi-Touch Control Wheel Software Development Kit User s Guide
Multi-Touch Control Wheel Software Development Kit User s Guide V3.0 Bulletin #1204 561 Hillgrove Avenue LaGrange, IL 60525 Phone: (708) 354-1040 Fax: (708) 354-2820 E-mail: [email protected] www.grayhill.com/instinct
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
Wireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION
Calibration Guide PREPARATION Adventurer Pro Adventurer Pro balances have two calibration methods: Span and Linearity. Some models have Internal Calibration (InCal ) for Span calibration. Ensure that the
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter
MODEL PRO-9744 INSTALLATION MANUAL Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter This System Allows The Transmitter Buttons To Be
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall
Practice Test SHM with Answers
Practice Test SHM with Answers MPC 1) If we double the frequency of a system undergoing simple harmonic motion, which of the following statements about that system are true? (There could be more than one
MGB Chrome Bumper Conversion
MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different
Quick Start Guide See Inside for Use and Safety Information
3 rd Generation Personal 3D Printer Quick Start Guide See Inside for Use and Safety Information The USB Mass Storage Device Contains the User Guide and Quick Start Guide in other Languages Congratulations
CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions
Printing 3 March 2008 CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions This instruction is intended for CP2 cable pedestal installations and replacements. The following tools will be
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
How To Wire Wireline Cable To A Cell Phone (New Zealand)
Installation Guide EnerNOC Site Server - S2 Installation Guide - AUS, NZ v 1.7 EnerNOC New Zealand Limited 2 Collina Terrace PO Box 12-202 Thorndon Wellington NZ 6144 +64 4 909 7546 1 Table of Contents
EasyNote TJ Series. Disassembly Manual
EasyNote TJ Series Disassembly Manual CHAPTER3 Replacing notebook components Preventing static electricity discharge Preparing the work space Required tools Preparing the notebook Adding or replacing memory
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
MODEL 2202IQ (1991-MSRP $549.00)
F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR
Networkfleet 3500 Product Line Installation Guide
Networkfleet 3500 Product Line Installation Guide Light/Medium Duty (L3500) Heavy Duty (H3500) Universal (U3500) www.networkcar.com/fleet Customer Care: (866) 227-7323 [email protected] Table
Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015
Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) The standard tuning values used in ADVANCED Motion Controls drives are conservative and work well in over 90%
Tooway KA-SAT Installation Guide
Tooway KA-SAT Installation Guide 1. Before you can proceed with the installation you must get the following information: Spot beam colour for you location Elevation Angle the dish needs to be set to Azimuth
DISSOLVED OXYGEN METER Model : DO-5509
DISSOLVED OXYGEN METER Model : DO-5509 Your purchase of this DISSOLVED OXYGEN METER marks a step forward for you into the field of precision measurement. Although this DISSOLVED OXYGEN METER is a complex
GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847 673-5009 email@gaertnerscientific.
7109-C-244E-R1 Field Installation of HeNe Laser in B, C, and D-Type Auto Gain Ellipsometers GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847
Servo Info and Centering
Info and Centering A servo is a mechanical motorized device that can be instructed to move the output shaft attached to a servo wheel or arm to a specified position. Inside the servo box is a DC motor
LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE
LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE Applies to Models: 75W, 150W, 300W, 600W, 900W, 1200W ATTENTION: Please read this guide carefully to ensure safe and efficient
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Data-Logging Rain Gauge PRODUCT MANUAL
Data-Logging Rain Gauge PRODUCT MANUAL Item # 3554WD1 Thank you for purchasing a Spectrum Datalogging Rain Gauge. With proper installation and care, it will give you years of accurate and reliable measurements.
OxySense Portable Series Instrument Quick Start Guide
OxySense Portable Series Instrument Quick Start Guide OxySense, Inc. 13111 North Central Expressway, Suite 440 Dallas, Texas 75243 U.S.A. +1 214 575 7600 Page i Document Revised: March 5, 2014 All Rights
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
USER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
Operating Instructions Bedienungsanleitung Mode d emploi
Operating Instructions Bedienungsanleitung Mode d emploi DW 400 www.bron-kobold.com Operating instructions DW 400 Before use Please read all the information contained in these operating instructions carefully.