Miniature Circuit-Breaker IEC Series 8562

Size: px
Start display at page:

Download "Miniature Circuit-Breaker IEC Series 8562"

Transcription

1 > 1 to 3 pole versions > Rated current from A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E > Isolating Function to E > Permanently set thermal and magnetic trips > Power limitation class 3 /5 miniature circuit-breakers meet all technical requirements relating to safe and selective tripping. When short-circuits occur, they restrict the load on the installed circuits due to their excellent current limiting and related high breaking capacity and provide a high level of discrimination for lineside fuses. ATEX / IECEx Zone For use in x x 12503E00 WebCode 8562B Components for System Solutions /1

2 Selection Table MCB 8562 for AC, C-Characteristic Breaking capacity o. of poles Rated operational current Additional options Module width Order number Weight ka mm kg 6 1 pole 1 A without / A without / A without / A without / A without / A without / A without / A without / pole + 1 A without / A without / A Auxiliary / contact 1 changeover 4 A without / A without / A Auxiliary / contact 1 changeover 10 A without / A Fault signal, / changeover 16 A without / pole 2 A without / A without / A without / A without / A without / A without / pole 2 A without / A without / A without / A without / A Auxiliary / contact 1 changeover 16 A without / A without / A without / A without / pole + 10 A without / A without / A without / pole + 16 A without / pole 10 A without / A without / pole 32 A without / pole + 32 A without / other versions and accessories on request /2 Components for System Solutions

3 Selection Table MCB 8562 for AC, B-Characteristic Breaking capacity o. of poles Rated operational current Additional options Module width Order number Weight ka mm kg 6 1 pole 6 A without / pole 10 A without / pole 16 A without / pole + 6 A without / pole + 10 A without / pole + 10 A Auxiliary / contact 1 changeover 6 1 pole + 16 A without / pole + 20 A without / pole 10 A without / pole 16 A without / pole 25 A without / pole 32 A without / pole 16 A without / pole + 6 A without / pole + 10 A without / pole 16 A without / other versions and accessories on request Miniature Circuit-Breaker 1-pole B-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/ / / E00 Supplement / Breaking cpacity AC 6 ka 8562/ / AC 10 ka 8562/ / AC / DC 6 ka 8562/ UL 10 ka 8562/ / CO / Components for System Solutions /3

4 Miniature Circuit-Breaker 1-pole C-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/ / / E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / AC / DC 6 ka 8562/ UL 10 ka 8562/ / UL 135 % 10 ka 8562/ / CO / / / / / / / / / / / Miniature Circuit-Breaker 1-pole D-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/ / / E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / CO / / / / / / / / / / / /4 Components for System Solutions

5 Miniature Circuit-Breaker 1-pole Z-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/ / / E00 Supplement / AC 10 ka 8562/ / CO / / / / / / / / / / / Miniature Circuit-Breaker 1-pole + B-Characteristic Module width Width 54 mm Width 72 mm 1/2 8562/ / / E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / Auxiliary contact without 8562/ CO / Fault signal 1 CO / Components for System Solutions /5

6 Miniature Circuit-Breaker 1-pole + C-Characteristic Module width Width 54 mm Width 72 mm 1/2 8562/ / / E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / UL 135 % 10 ka 8562/ / Auxiliary contact without 8562/ CO / Fault signal 1 CO / current A 0,5 8562/ / / / / / / / / / Miniature Circuit-Breaker 1-pole + D-Characteristic Module width 1/2 Width 72 mm 8562/ / E00 Supplement / AC 6 ka 8562/ AC 10 ka 8562/ UL 10 ka 8562/ Auxiliary contact without -- 1 CO 8562/ Fault signal 1 CO 8562/ / / / / / / / / / / / / /6 Components for System Solutions

7 Miniature Circuit-Breaker 2-pole B-Characteristic Module width Width 54 mm Width 72 mm 1/2 3/4 8562/ / /1 4/ E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / AC / DC 6 ka 8562/ UL 10 ka 8562/ / CO / order spec / current A Miniature Circuit-Breaker 2-pole C-Characteristic Module Width Width 54 mm Width 72 mm 1/2 3/4 8562/ / /1 4/ E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / AC / DC 6 ka 8562/ UL 10 ka 8562/ / UL 135 % 10 ka 8562/ / CO / order spec / / / / / / / / / / / Components for System Solutions /7

8 Miniature Circuit-Breaker 2-pole D-Characteristic Module Width Width 54 mm Width 72 mm 1/2 3/4 8562/ / /1 4/ E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / CO / order spec / / / / / / / / / / / Miniature Circuit-Breaker 2-pole Z-Characteristic Module Width Width 54 mm Width 72 mm 1/2 3/4 8562/ / /1 4/ E00 Supplement / AC 10 ka 8562/ / CO / / / / / / / / / / / /8 Components for System Solutions

9 Miniature Circuit-Breaker 3-pole B-Characteristic Module width Width 72 mm Width 99 mm 1/2 3/4 5/6 8562/ / /1 4/3 6/ E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / CO / CO - 1 CO normal and Fault signal 1 CO / Miniature Circuit-Breaker 3-pole C-Characteristic Module width Width 72 mm Width 99 mm 1/2 3/4 5/6 8562/ / /1 4/3 6/ E00 Supplement / Breaking capacit AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / UL 135 % 10 ka 8562/ / CO / CO - 1 CO normal and fault signal 1 CO / / / / / / / / / / / Components for System Solutions /9

10 Miniature Circuit-Breaker 3-pole D-Characteristic Module width Width 72 mm Width 99 mm 1/2 3/4 5/6 8562/ / /1 4/3 6/ E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / CO / CO - 1 CO normal and fault signal 1 CO / / / / / / / / / / / Miniature Circuit-Breaker 3-pole + B-Characteristic Module width 1/2 3/4 5/6 Width 99 mm 8562/ /1 4/3 6/ E00 Supplement / AC 10 ka 8562/ UL 10 ka 8562/ Auxiliary contact without 8562/ CO 8562/ Fault signal 1 CO 8562/ CO - 1 CO normal and Fault signal 1 CO 8562/ / / / / / / / /10 Components for System Solutions

11 Miniature Circuit-Breaker 3-pole + C-Characteristic Module width 1/2 3/4 5/6 Width 99 mm 8562/ /1 4/ E00 Supplement / AC 6 ka 8562/ AC 10 ka 8562/ UL 10 ka 8562/ UL 135 % 10 ka 8562/ Auxiliary contact without 8562/ CO 8562/ Fault signal 1 CO 8562/ CO - 1 CO normal and Fault signal 1 CO 8562/ Miniature Circuit-Breaker 3-pole + D-Characteristic Module width 1/2 3/4 2/1 4/3 6/5 5/6 6/ E / / / / / / / / / / / / Width 99 mm 8562/ Supplement / AC 6 ka 8562/ AC 10 ka 8562/ UL 10 ka 8562/ Auxiliary contact without 8562/ CO 8562/ Fault signal 1 CO 8562/ CO - 1 CO normal and Fault signal 1 CO 8562/ / / / / / / / / / / / / Components for System Solutions /11

12 Explosion Protection Marking IECEx Ex d e IIC Ex d e I Europe (ATEX) E II 2 G Ex d e IIC Gb E I M 2 Ex d e I Mb Certificates IECEx IECEx PTB U Europe (ATEX) PTB 02 ATEX 1049 U Other certificates Belarus (Gospromnadzor) Technical Data Device version AC MCBs AC / DC MCBs o. of poles 1 pole, 1 pole +, 2 pole, 3 pole, 3 pole + 1 pole, 2 pole Electrical data AC MCBs AC / DC MCBs voltage Standard version Standard version AC DC AC 1 pole 230 V 48 V 1 pole V pole 230 / 400 V 110 V 1) 3 pole 230 / 400 V pole / 400 V - - 1) 2 poles in series UL- 1 pole 277 V 2) 60 V 2) 1 pole 230 V 3) 60 V 3) 2 pole 277 / 480 V 2) 125 V 2) 2 pole 230 / 400 V 3) 125 V 3) 3 pole 277 / 480 V 2) 125 V 2) 3 pole 230 / 400 V 3) 125 V 3) 2) acc. to UL ) acc. to E DC 1 pole 230 V 220 V 1 pole pole 230 / 400 V 220 V 440 V 1) 1) 2 poles in series Minimal Voltage U bmin 12 V AC / DC 12 V AC / DC Maximal Voltage U bmax AC 250 V / 440 V AC 250 V / 440 V DC 53 V / 120 V DC 250 V / 440 V Rated insulation voltage 500 V 500 V current Tripping characteristic B A Tripping characteristic B Tripping characteristic C/D/Z A Tripping characteristic C/D Rated frequency 50 / 60 Hz 50 / 60 Hz DC Isolation function yes (IEC/E ) yes (IEC/E ) Pulse resistance 6 kv 6 kv Utilization category A (IEC/E ) A (IEC/E ) A 0, A /12 Components for System Solutions

13 Technical Data Electrical data Tripping characteristic curves 08903E E02 Components for System Solutions /13

14 Technical Data Electrical data Tripping characteristic curves Tripping Z-characteristic curve Selectivity class 3 (IEC/E 60898) 6 ka resp. 10 ka Rated switching capacities AC MCBs Poles Series with 6 ka Series with 10 ka Voltage Current Voltage Current (V) (ka) (V) (ka) AC to IEC/E I cn 230 / I cn 230 / AC to IEC/E I cu I cu , I cu I cu I cu I cu DC to IEC/E (Time constante 15 ms) 01546E02 1 I cu / I cs I cu / I cs AC / DC MCBs AC to IEC/E I cn I cn 230 / DC to IEC/E I cu / I cs / Circuit breaker, current limiting with thermal and magnetic release /14 Components for System Solutions

15 Technical Data Characteristics Characteristic to IEC/E Rated current range Loads ormal temperature Thermal overload trip Z B C D A A A A > Semiconductor devices > Elektric heatings > Lighting > Socket outlet circuits > Control circuits e.t.c. > Operating > Operating equipment equipment > Light fitting groups > Motors with > Motors heavy starting > Transformers characteristic e.t.c. e.t.c. 20 C 30 C 30 C 30 C 30 C I n I n I n ,45 I n I n Thermal overload I n -- trip 135% UL Magnetic trip I n I n I n I n Components for System Solutions /15

16 Technical Data Electrical data Response value of short-circuit trip Back-up protection Service life Electrical Mechanical Auxiliary contact Rated working current Ambient Conditions Ambient temperature Correction factors The response value of the short-circuit trip is approximately 40 % higher for DC than for AC at 50 / 60 Hz Fuses must be fitted upstream to protect miniature circuit-breakers against high short-circuit currents in high power networks. These protect the miniature circuit-breakers against short-circuit currents of up to 50 ka. If a short-circuit occurs, both protective devices cut out simultaneously, so that the miniature circuit-breaker is not destroyed and remains fully functional. Following MCBs Type 10 4 switching cycles 2x10 4 switching cycles see circuit diagrams 5 A at 230 V AC 1 A at 60 V DC MCB tripping characteristic Rated operational current I th (A) C, D B, Z B, C, D, Z Preceding fuse type gg Minimal rated operational current (A) 8562/ C In case of different temperature range please consider correction factor! Correction factors for ambient temperatures other than 30 C Maximal rated operational current (A) 10889E E E00 /16 Components for System Solutions

17 Technical Data Mechanical data Degree of protection Degree of protection acc. to IEC/E Connecting terminals IP20 Material Enclosure Epoxy resin Mounting / Installation Terminals Main contacts mm 2 clamp terminals Auxilliary contacts 1.5 mm 2 clamp terminals Schematic 1/2 1/2 1/2 3/4 1/2 3/4 5/6 2/1 2/1 2/1 4/3 2/1 4/3 6/ E E E E00 1 pole 1 pole + 2 pole 3 pole 1/2 3/4 5/ /1 4/3 6/ E E E00 3 pole + Universal current +/-, 1 pole Universal current +/-, 2 pole E E E E00 Auxiliary contact 1 CO Fault indication contact 1 CO Auxiliary contact 1 O Fault indication contact 1 O Auxiliary contact 1 CO Fault indication contact 1 CO U> U< C2 C E00 D1 D E00 Remote trip Undervoltage trip Components for System Solutions /17

18 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Ø5, ,50 R5, ,50 R5,50 5, ,50 R2, , , E E00 MCB 8562/ MCB 8562/ R5, R5, ,50 5,50 R5,50 R5,50 5, R2, , R2, , E E00 MCB 8562/ MCB 8562/ We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /18 Components for System Solutions

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Control and Distribution Boxes made of Stainless Steel Series 8150

Control and Distribution Boxes made of Stainless Steel Series 8150 www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

The complete range of consumer switchboards and switchgear

The complete range of consumer switchboards and switchgear Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole) Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

System pro M compact Miniature Circuit Breaker S 200/S 200 M

System pro M compact Miniature Circuit Breaker S 200/S 200 M Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

How can a charging station for electric vehicles be set up simply and safely?

How can a charging station for electric vehicles be set up simply and safely? SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010 Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.05 2010 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.05 2010 Contents Contents Page 3AH5 Vacuum Circuit-Breakers Medium-Voltage

More information

MOTOR PROTECTIVE DEVICES

MOTOR PROTECTIVE DEVICES W MOTOR PROTECTIVE DEVICE, SERIES MP 206 BE400206 BE400306 Inherently stable without back-up fuseup to 4 A at 400 V AC, > 4 A main back-up fuse 100 A gl Thermal and magnetic release Terminal and accessory

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Residual Current Protective Devices

Residual Current Protective Devices Residual Current Protective Devices /2 Introduction / 5SM3 RCCBs /9 SIQUENCE, 5SM3 and 5SU1 universal -sensitive RCCBs, type B and type B+ /12 Additional components /1 5SM2 RC units /18 5SU1 RCBOs /25

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10 ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection Technical data RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection When connecting aluminium conductors ensure that the contact surfaces of the conductors

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA Miniature Circuit Breaker SU 200 M The next generation MCB for UL/CSA applications within

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

Flameproof Audible Signal 115 db (A) Series YA90

Flameproof Audible Signal 115 db (A) Series YA90 Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light

More information

Residual current socket 30mA Order No.: 0477..

Residual current socket 30mA Order No.: 0477.. 30mA Order o.: 0477.. 1. Operating description The operating principle of the residual current socket is identical to that of the residual current device. In a fault-free installation, in which no current

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2 Overview Description, device design, dimension drawing 1 Power supply Operating Instructions Mounting/Disassembly 2 Mounting position, installation clearances 3 Installation 4 Applications 5 Technical

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Low Voltage Products. Switches Automatic Transfer Switches

Low Voltage Products. Switches Automatic Transfer Switches Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly Overview Safety instructions 1 Power supply Operating Instructions Description, device design, dimension drawing 2 Mounting/disassembly 3 Mounting position, mounting clearances 4 Installation 5 Technical

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Breaking and protection devices

Breaking and protection devices Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while

More information

7 - Phaseo power supplies and transformers

7 - Phaseo power supplies and transformers /0 Contents 0 - Phaseo power supplies and transformers Selection guide: Phaseo power supplies Modular, Optimum and universal ranges........................ page /2 Selection guide: Phaseo power supplies

More information

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection

More information

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information